Note: Dimensions in Brackets are Expressed in Millimeters and are for Reference Only. 8516: REV K
SPECIFICATIONS:
Models:
SPECIFICATIONS:
Models: 8516-XX
DC BLOCKING ATTENUATOR
TNC, 2 GHz, 200 Volts
Mechanical:
Electrical:
Mates with MIL-STD-348
In 1 dB Increments
VSWR:
DC Block Type
Voltage Rating
Operating Temp. Range
Connectors:
Conductors:
Impedance:
Frequency Range
1.15:1 Max.
Passivated Stainless Steel
Inner Only
200 Volts
-65°C to +125°C
10 MHz - 2 GHz
50 Ohms
Standard dB Values* 0-10,12,15&20dB
Accuracy of Attenuation:
1-6dB
7 - 20 dB
± 0.3 dB
±0.5dB
2 Watts Average
Input Power
Gold Plated Beryllium Copper
RF in
Schematic Diagram
RF out
8516-XXModel Number:
Male/Female Connectors
Ø.56 [14.22]
2.38 ± .03
[60.45 ± 0.76]
dB Value
M = Male/Male
Connector Configuration
F = Fem/Fem
= Male/Female
Model Number:
HOW TO ORDER:
8516-XXY
8516-05FModel Number:
2 GHz; 5 dB; TNC - Fem/Fem
Ordering Examples:
2 GHz; 20 dB; TNC - Male/Fem
Model Number: 8516-20
Length: 2.38 ±.03 [60.45 ±0.76]
Pictured
8516-XXM
Male/Male Connectors
Model Number:
Length: 2.28 ±.05 [57.91 ±1.27]
8516-XXF
Female/Female Connectors
Model Number:
Length: 2.47 ±.03 [62.74 ±1.27]
Unit is a unidirectional device. Input shall be at male port unless otherwise specified.
Aeroflex / Inmet, Inc. 300 Dino Drive, Ann Arbor, MI 48103 • U.S.A.
888-244-6638 or 734-426-5553 FAX: 734-426-5557
www.aeroflex-inmet.com • inmetsales@aeroflex.com