ADP Series Power Adapters
19V 40W/65W/90W
!
!
!www.DeltaPSU.com (January 2016, Rev. 1.0)!!
!
Output Ratings / Characteristics
The output voltage shall be sustained 5mS within regulation requirement after loss 100Vac
and maximum load.
DC output rise time from
10% to 90% of output
voltage shall be less than
30mS at nominal line
and maximum load
DC output rise time from 10% to 90% of output voltage shall be
less than 100ms at nominal line and maximum load
0.1A to 100% load at 2.5A/us slew rate and frequency is
10Hz to 10KHz
0% to 50% and 50% to 100%
1.0A/us slew rate and frequency
is 100Hz
Shipping/Storage Temperature
8% to 90% RH (Non-Condensing)
Shipping/Storage Humidity
5% to 95% RH (Non-Condensing)
IEC-1000-4-5 Level 3
Requirements
L-N 1KV/1.2 * 50uS 5
times No damage
IEC-61000-4-5 Level 3 requirements
L-N 1KV/1.2 * 50uS 5 times No function error
L-FG 2KV/1.2 * 50uS 5 times No damage.
Electric Fast Transients (EFT)
IEC-1000-4-4/1995
EN 61000-4-4
Electrostatic Discharge (ESD)
±15KV air discharge
±8KV contact discharge
Dielectric Withstand Voltage (HI-
POT)
Between AC input and
secondary AC 3KV test
time 1 minute; 100% of line
products of this Adapter
shall be applied 3000Vac
for 2 seconds between AC
input terminals and output
terminals. Cut off current
3mA.
Between AC input and
secondary AC 3KV test time
1 minute; 100% of line
products of this Adapter
shall be applied 3000Vac
for 2 seconds between AC
input terminals and output
terminals. Cut off current
10mA.
100% of line products of this
Adapter shall be applied
3000Vac for 1 seconds between
AC input terminals and output
terminals. Cut off current is
10mA.
The insulation resistance shall be not less than 30M ohms
after application of 500Vdc/10mA for 1 minute.
The insulation resistance shall
be not less than 20M ohms after
application of 500Vdc/10mA for
1 minute
Electromagnetic Interference (EMI)
(a) FCC Class B
(b) CISPR 22 Class B
(c) VCCI Class B
(a) FCC Class B
(b) CISPR 22 Class B
(c) VCCI Class B
(a) FCC Class B
(b) CISPR 22 Class B
(c) VCCI Class B