C4700 OCXO
Vectron International · www.vectron.com
v.2008-05-27 · page 1 of 4
Vectron International
Headquarters
267 Lowell Road
Hudson, New Hampshire 03051
+1-888-328-7661 tel
+1-888-329-8328 fax
Vectron International LLC.
100 Watts Street
Mount Holly Springs, PA 17065
USA
+1-717-486-3411 tel
+1-717-486-5920 fax
Vectron international GmbH & Co. KG
Landstrasse
D-74924 Neckarbischofsheim
Germany
+49-07268-801-0 tel
+49-07268-801-281 fax
Vectron Asia Pacific Sales Office
Unit 3119 31st Floor, Jin Mao Tower, 88
Century Boulevard, Shanghai,
P.R. China 200120
+86 21 28909740 tel.
+86 21 28909240 fax
Typical Applications Features
CDMA2000 and UMTS Base Stations Ultra-High Stability
Test and Measurement Equipment Excellent Temperature Stability
SC-Cut Crystal Crystal
Previous Vectron Model Numbers
4895, OC-050, CO-330
Frequency range 4 MHz – 15 MHz
Standard frequencies 5; 10; 15MHz
Frequency stabilities
1
[SC Cut Crystal – Standard]
Parameter Min Typ Max. Units Operating temp
range Ordering Code
vs. operating temperature range -0.4 +0.4 ppb 0 … +70°C C049
(peak to peak stability) -0.2 +0.2 ppb 0 … +70°C C029
-0.4 +0.4 ppb -20 … +70°C D049
Parameter
Min Typ Max. Units Condition
Initial tolerance
vs. supply voltage change
vs. load change
vs. aging /1 day
vs. aging /1 day
vs aging /1 Year
vs. aging / year (following years)
-50
-0.1
-0.1
-0.5
-0.2
-20
-10
+50
+0.1
+0.1
+0.5
+0.2
+20
+10
ppb
ppb
ppb
ppb
ppb
ppb
at time of shipment, nominal EFC
V
S
± 5%
Load ± 5%
after 72 hours of operation
after 7 days of operation
after 72 hours of operation
Warm-up Time 5 minutes to ± 10ppb of final frequency (1 hour reading) @
+25°C
Supply voltage (Vs)
Parameter Min Typ Max. Units Condition Ordering Code
Supply voltage [Standard] 11.4 12.0 12.6 VDC SV120
Supply voltage [Standard] 4.75 5.0 5.25 VDC SV050
Power consumption @+12V 12 Watts during warm-up
4 Watts steady state @ +25°C
Power consumption @+5V 10 Watts during warm-up
4 Watts steady state @ +25°C
RF output
Parameter Min Typ Max. Units Condition Ordering Code
Signal [Standard] HCMOS RFH
Load 15 pF
Signal Level (Vol) 0.5 VDC 15pF load
Signal Level (Voh) 4.5 VDC 15pF load
Duty cycle 45 55 % @ (Voh-Vol)/2
Signal [Option] Sinewave RFS
Load 50 Ω
Output Power +5.0 +7.0 +9.0 dBm 50 Ohm load
Harmonics -30 dBc 50 Ohm load
Sub-Harmonics -40 dBc 50 Ohm load