μμ
Universal AC input / Full range
Built-in active PFC function, PF>0.94
High efficiency up to 89%
Withstand 300VAC surge input for 5 seconds
Protections: Short circuit / Overload / Over voltage / Over temperature
Medical safety approved (MOOP level)
Built-in cooling fan ON-OFF control
Built-in DC OK signal
Built-in remote ON-OFF control
Standby 5V@0.3A
Built-in remote sense function
No load power consumption<0.8W (Note.7)
Current sharing up to 2400W (3+1) (24V,36V,48V)
5 years warranty
SPECIFICATION
MSP-600-3.3 MSP-600-5 MSP-600-7.5 MSP-600-12 MSP-600-15 MSP-600-24 MSP-600-36 MSP-600-48
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
RIPPLE & NOISE (max.) Note.2
OUTPUT VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.3
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE Note.5
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
INPUT
ENVIRONMENT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVER TEMPERATURE
SAFETY STANDARDS
SAFETY &
FUNCTION
EMC
(Note 4)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
WORKING TEMP.
DC OK SIGNAL
REMOTE CONTROL
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
PROTECTION
AC CURRENT (Typ.)
3.3V 5V 7.5V 12V 15V 24V 36V 48V
120A 120A 80A 53A 43A 27A 17.5A 13A
0 ~ 120A 0 ~ 120A 0 ~ 80A 0 ~ 53A 0 ~ 43A 0 ~ 27A 0 ~ 17.5A 0 ~ 13A
396W 600W 600W 636W 645W 648W 630W 624W
100mVp-p 100mVp-p 100mVp-p 120mVp-p 150mVp-p 150mVp-p 200mVp-p 240mVp-p
2.8 ~ 3.8V 4.3 ~ 5.8V 6.8 ~ 9V 10.2 ~ 13.8V 13.5 ~ 18V 21.6 ~ 28.8V 28.8 ~ 39.6V 40.8 ~ 55.2V
±2.0% ±2.0% ±2.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
±0.5% ±0.5% ±0.5% ±0.3% ±0.3% ±0.2% ±0.2% ±0.2%
±1.0% ±1.0% ±1.0% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
1000ms, 50ms/230VAC 2500ms, 50ms/115VAC at full load
16ms/230VAC 16ms/115VAC at full load
85 ~ 264VAC 120 ~ 370VDC
47 ~ 63Hz
PF>0.94/230VAC PF>0.99/115VAC at full load
78.5% 82%
6 ~ 7V 9.4 ~ 10.9V 14.4 ~ 16.8V 18.8 ~ 21.8V 30 ~ 34.8V 41.4 ~ 48.6V 57.6 ~ 67.2V
86% 88% 88% 88% 89% 89%
8.5A/115VAC 5A/230VAC
35A/115VAC 80A/230VAC
105 ~ 135% rated output power
3.96 ~ 4.62V
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Protection type : Shut down o/p voltage, re-power on to recover
Shut down o/p voltage, recovers automatically after temperature goes down
ANSI/AAMI ES60601-1, IEC60601-1 EAC TP TC 004 approved
,
Compliance to EN55011 (CISPR11) Class B, EN61000-3-2,-3, EAC TP TC 020
Compliance to EN61000-4-2,3,4,5,6,8,11, EN60601-1-2, EAC TP TC 020
I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
-40 ~ +70 (Refer to "Derating Curve")
RC+ / RC-: 4 ~ 10V or open = power on ; 0 ~ 0.8V or short = power off
PSU turn on : 3.3 ~ 5.6V ; PSU turn off : 0 ~ 1V
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH non-condensing
±℃0.03%/ (0 ~ 50 )
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
138.7K hrs min. MIL-HDBK-217F (25 )
218*105*63.5mm (L*W*H)
File Name:MSP-600-SPEC 01-152018-
Features :
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a mm* mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives.360 360 For guidance on how to
perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com)
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. No load power consumption<0.8W when RC+ & RC- (CN100 pin3,4) 0 ~ 0.8V or short.
8. When the input voltage is less than 40VAC, the SPS may exhibit degradation of performance. The final product manufacturers must re-confirm this
deviation that does not affect basic safety or essential performance.
9. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
MSP-600 series
600W Single Output Medical Type
1.57Kg;8pcs/13.6Kg/1.34CUFT
5V STANDBY
5VSB : 5V@0.3A ; tolerance 5%, ripple : 50mVp-p(max.)±
FAN CONTROL (Typ.)
Load 35 15% or RTH2 50 Fan on±≧
EMC IMMUNITY
EMC EMISSION
Earth leakage current < 300 A/264VAC , Touch leakage current < 100 A/264VAC
ISOLATION LEVEL
Primary-Secondary: 2×MOOP, Primary-Earth: 1×MOOP, Secondary-Earth: 1×MOOP
Mechanical SpecificationMechanical Specification Case No. 977A Unit:mm
AC Input Terminal Pin No.
Assignment
DC Output Terminal Pin No.
Assignment
Pin No. Pin No.
1 1~3
3
2 4~6
Assignment Assignment
AC/N +V
AC/L -V
FG
Derating Curve Output Derating VS Input Voltage
INPUT VOLTAGE (V) 60Hz
85 100 125 135 155 264
100
90
80
70
60
50
40
LOAD(%)
AMBIENT TEMPERATURE ( )
LOAD (%)
-40010203040506070
20
50
80
100
125
(HORIZONTAL)
PWM fosc : 70KHz
CN100
LED
(Vo ADJ.)SVR1
Block Diagram
Pin No. Pin No.
7
6,8
5
3
2
1
9
410
Assignment
-S
+S
DC-OK
GND
CS
Assignment
RC-
RC+
AUX
AUXG
Mating Housing Terminal
or equivalent or equivalent
Connector Pin No. Assignment(CN100) : HRS DF11-10DP-2DS or equivalent
HRS DF11-10DS
HRS DF11-**SC
O.L.P.
O.T.P.
EMI INRUSH
ACTIVE
FILTER CURRENT
LIMITING
RECTIFIERS
&
PFC
I/P
FG
PWM
PFC
CIRCUIT
SHARING
DETECTION
CURRENT
POWER
AUX
SWITCHING
POWER
FILTER
FILTER
&
&
RECTIFIERS
RECTIFIERS
CONTROL
CONTROL
O.V.P.
O.T.P.
REMOTE
CONTROL
105
18max.
119.2
O/P
1
2
3
4
5
6
Air flow
direction
63.5
3
2
1
I/P
4-M4 L=6
12max.
8.2
63.5 20.75
10
218
32.8152.4
8-M4 L=4 (Both Sides)
32.8
38.312.5
152.4
+V
+S
AUX
-V
-S
AUXG
RC+
CS
DC OK
RC-
600W Single Output Medical Type
File Name:MSP-600-SPEC 01-152018-
MSP-600 series
1
2
9
10
The remote sensing compensates voltage drop on
the load wiring up to 0.5V.
10
10
9
9
CN100
AUX
RC-
GND
GND
-S
AUXG
RC+
CS
DC-OK
+S
2
2
1
1
1.Remote Sense
1
1
9
9
10
10
Sense lines should
be twisted in pairs
LOAD
-
+
+S -S
(Pin9) (Pin10)
Fig 1.1
Between DC-OK(pin7) and GND(pin6,8)
3.3 ~ 5.6V
0 ~ 1V
Output Status
ON
OFF
DC-OK signal is a TTL level signal. High when PSU turns on. CN100
AUX
RC-
GND
GND
-S
AUXG
RC+
CS
DC-OK
+S
2.DC-OK Signal
Fig 2.1
CN100
CN100
2
2
5CS
Current sharing signal. When units are connected in parallel, the CS pins of the units should be connected to allow current balance
between units.
7DC-OK DC-OK signal is a TTL level signal, referenced to pin8(DC-OK GND). High when PSU turns on.
9+S
Positive sensing. The +S signal should be connected to the positive terminal of the load. The +S and -S leads should be twisted in pair to
minimize noise pick-up effect. The maximum line drop compensation is 0.5V.
10 -S Negative sensing. The -S signal should be connected to the negative terminal of the load. The -S and +S leads should be twisted in pair to
minimize noise pick-up effect. The maximum line drop compensation is 0.5V.
6,8 GND This pin connects to the negative terminal(-V). Return for DC-OK signal output.
600W Single Output Medical Type
File Name:MSP-600-SPEC 01-152018-
MSP-600 series
Function Description of CN100
Pin No. Function Description
Function Manual
3
4
RC+
RC- Remote control ground.
Turns the output on and off by electrical or dry contact between pin 4 (RC-), Short: Power OFF, Open: Power ON.
2
1
AUX
AUXG Auxiliary voltage output ground. The signal return is isolated from the output terminals (+V & -V).
Auxiliary voltage output, 4.75~5.25V, referenced to pin 1(AUXG). The maximum load current is 0.3A. This output is not controlled by the
"remote ON/OFF control".
10 9
21
1
9
10
CN100
2
600W Single Output Medical Type
File Name:MSP-600-SPEC 01-152018-
MSP-600 series
Between RC+(pin3) and RC-(pin4)
SW ON (Short)
SW OFF (Open)
Output Status
OFF
ON
The PSU can be turned ON/OFF by using the
"Remote Control" function.
SW
CN100
AUX
RC-
GND
GND
-S
AUXG
RC+
CS
DC-OK
+S
3.Remote Control
Fig 3.1
PSU2PSU1 PSU3 PSU4
Fig 4.1
LOAD
Sense lines should
be twisted in pairs
+V -V
-V-V -V -V
CN100 CN100CN100CN100
+V+V +V +V
10101010
9999
AUXAUX AUX AUXRC-RC- RC- RC-GNDGND GND GNDGNDGND GND GND-S-S -S -S
AUXGAUXG AUXG AUXG
RC+RC+ RC+ RC+CSCS CS CS
DC-OKDC-OK DC-OK DC-OK
+S+S +S +S
2222
CN100CN100
PSU2PSU1 PSU3 PSU4
CN100 CN100
1111
Note : 1.In parallel connection, maybe only one unit (master) operate if the total output load is less than 2% of rated load condition.
The other PSU (slave) may go into standby mode and its output LED and relay will not turn on.
2.2% min. of dummy load is required.
4.Current Sharing with Remote Sensing (Only for 24V, 36V and 48V)
MSP-600 has the built-in active current sharing function and can be connected in parallel to provide higher output power :
(1)Parallel operation is available by connecting the units shown as below.
(2)Difference of output voltages among parallel units should be less than 2%.
(3)The total output current must not exceed the value determined by the following equation.
(4)In parallel operation 4 units is the maximum, please consult the manufacturer for applications of more connecting in parallel.
(5)The power supplies should be paralleled using short and large diameter wiring and then connected to the load.
(+S,-S,CS and GND are connected mutually in parallel).
(output current at parallel operation)=(Rated current per unit) (Number of unit) 0.9××