MSP-600 600W Single Output Medical Type series Features : Universal AC input / Full range Built-in active PFC function, PF>0.94 High efficiency up to 89% Withstand 300VAC surge input for 5 seconds Protections: Short circuit / Overload / Over voltage / Over temperature Medical safety approved (MOOP level) Built-in cooling fan ON-OFF control Built-in DC OK signal Built-in remote ON-OFF control Standby 5V@0.3A Built-in remote sense function No load power consumption<0.8W (Note.7) Current sharing up to 2400W (3+1) (24V,36V,48V) 5 years warranty SPECIFICATION MODEL OUTPUT MSP-600-3.3 MSP-600-5 MSP-600-7.5 MSP-600-12 MSP-600-15 MSP-600-24 MSP-600-36 MSP-600-48 DC VOLTAGE 3.3V 5V 7.5V 12V 15V 24V 36V 48V RATED CURRENT 120A 120A 80A 53A 43A 27A 17.5A 13A CURRENT RANGE 0 ~ 120A 0 ~ 120A 0 ~ 80A 0 ~ 53A 0 ~ 43A 0 ~ 27A 0 ~ 17.5A 0 ~ 13A RATED POWER 396W 600W 600W 636W 645W 648W 630W 624W RIPPLE & NOISE (max.) Note.2 100mVp-p 100mVp-p 100mVp-p 120mVp-p 150mVp-p 150mVp-p 200mVp-p 240mVp-p VOLTAGE ADJ. RANGE 4.3 ~ 5.8V 2.0% 6.8 ~ 9V 2.0% 10.2 ~ 13.8V 1.0% 13.5 ~ 18V 1.0% 21.6 ~ 28.8V 1.0% 28.8 ~ 39.6V 1.0% 40.8 ~ 55.2V 1.0% 2.8 ~ 3.8V VOLTAGE TOLERANCE Note.3 2.0% LINE REGULATION 0.5% 0.5% 0.5% 0.3% 0.3% 0.2% 0.2% 0.2% LOAD REGULATION 1.0% 1.0% 1.0% 0.5% 0.5% 0.5% 0.5% 0.5% SETUP, RISE TIME 1000ms, 50ms/230VAC HOLD UP TIME (Typ.) 16ms/230VAC 88% 89% 89% 41.4 ~ 48.6V 57.6 ~ 67.2V Note.5 85 ~ 264VAC VOLTAGE RANGE FREQUENCY RANGE 47 ~ 63Hz INPUT PF>0.94/230VAC EFFICIENCY (Typ.) 78.5% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 8.5A/115VAC 35A/115VAC OVERLOAD PROTECTION FUNCTION 120 ~ 370VDC POWER FACTOR (Typ.) LEAKAGE CURRENT OVER VOLTAGE 2500ms, 50ms/115VAC at full load 16ms/115VAC at full load PF>0.99/115VAC at full load 82% 86% 88% 88% 5A/230VAC 80A/230VAC Earth leakage current < 300A/264VAC , Touch leakage current < 100A/264VAC 105 ~ 135% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed 6 ~ 7V 9.4 ~ 10.9V 14.4 ~ 16.8V 18.8 ~ 21.8V 30 ~ 34.8V 3.96 ~ 4.62V OVER TEMPERATURE 5V STANDBY Protection type : Shut down o/p voltage, re-power on to recover Shut down o/p voltage, recovers automatically after temperature goes down 5VSB : 5V@0.3A ; tolerance5%, ripple : 50mVp-p(max.) DC OK SIGNAL PSU turn on : 3.3 ~ 5.6V ; PSU turn off : 0 ~ 1V REMOTE CONTROL RC+ / RC-: 4 ~ 10V or open = power on ; 0 ~ 0.8V or short = power off FAN CONTROL (Typ.) Load 3515% or RTH250 Fan on WORKING TEMP. -40 ~ +70 (Refer to "Derating Curve") 20 ~ 90% RH non-condensing WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85, 10 ~ 95% RH non-condensing TEMP. COEFFICIENT 0.03%/ (0 ~ 50) VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes SAFETY & EMC (Note 4) OTHERS SAFETY STANDARDS ISOLATION LEVEL ANSI/AAMI ES60601-1, IEC60601-1, EAC TP TC 004 approved Primary-Secondary: 2xMOOP, Primary-Earth: 1xMOOP, Secondary-Earth: 1xMOOP WITHSTAND VOLTAGE I/P-O/P:4KVAC ISOLATION RESISTANCE EMC EMISSION I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH Compliance to EN55011 (CISPR11) Class B, EN61000-3-2,-3, EAC TP TC 020 EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN60601-1-2, EAC TP TC 020 MTBF 138.7K hrs min. DIMENSION 218*105*63.5mm (L*W*H) 1.57Kg;8pcs/13.6Kg/1.34CUFT PACKING NOTE I/P-FG:2KVAC O/P-FG:0.5KVAC MIL-HDBK-217F (25) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) 5. Derating may be needed under low input voltages. Please check the derating curve for more details. 6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. 7. No load power consumption<0.8W when RC+ & RC- (CN100 pin3,4) 0 ~ 0.8V or short. 8. When the input voltage is less than 40VAC, the SPS may exhibit degradation of performance. The final product manufacturers must re-confirm this deviation that does not affect basic safety or essential performance. 9. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft). File Name:MSP-600-SPEC 2018- 01-15 MSP-600 600W Single Output Medical Type Mechanical Specification Case No. 977A O/P 2 105 4 5 9 2 10 CN100 218 152.4 32.8 8-M4 L=4 (Both Sides) 12.5 63.5 18max. 38.3 12max. 1 LED 6 1 2 3 (Vo ADJ.)SVR1 8.2 9.2 63.5 3 I/P 10 11 1 4-M4 L=6 Air flow direction Unit:mm 32.8 20.75 152.4 series AC Input Terminal Pin No. Assignment Pin No. 1 2 3 Connector Pin No. Assignment(CN100) : HRS DF11-10DP-2DS or equivalent DC Output Terminal Pin No. Assignment Assignment AC/L AC/N FG Pin No. 1~3 4~6 Pin No. 1 2 3 4 5 Assignment -V +V Assignment AUXG AUX RC+ RCCS Pin No. 6,8 7 9 10 Terminal Assignment Mating Housing GND DC-OK HRS DF11-10DS HRS DF11-**SC +S or equivalent or equivalent -S Block Diagram PWM fosc : 70KHz ACTIVE INRUSH CURRENT LIMITING EMI FILTER I/P RECTIFIERS & PFC AUX POWER RECTIFIERS & FILTER AUX AUXG +S POWER SWITCHING RECTIFIERS & FILTER +V -V -S DETECTION CIRCUIT O.L.P. O.T.P. FG DC OK O.T.P. PFC CONTROL PWM CONTROL Derating Curve CURRENT SHARING O.V.P. CS RC+ REMOTE CONTROL RC- Output Derating VS Input Voltage 100 125 90 100 80 70 LOAD(%) LOAD (%) 80 50 20 -40 0 10 20 30 40 50 AMBIENT TEMPERATURE () 60 70 (HORIZONTAL) 60 50 40 85 100 125 135 155 264 INPUT VOLTAGE (V) 60Hz File Name:MSP-600-SPEC 2018- 01-15 MSP-600 600W Single Output Medical Type series Function Description of CN100 Pin No. Function Description AUXG Auxiliary voltage output ground. The signal return is isolated from the output terminals (+V & -V). 1 Auxiliary voltage output, 4.75~5.25V, referenced to pin 1(AUXG). The maximum load current is 0.3A. This output is not controlled by the 2 AUX "remote ON/OFF control". 3 4 RC+ RC- 5 CS 6,8 7 9 10 Turns the output on and off by electrical or dry contact between pin 4 (RC-), Short: Power OFF, Open: Power ON. Remote control ground. Current sharing signal. When units are connected in parallel, the CS pins of the units should be connected to allow current balance between units. GND This pin connects to the negative terminal(-V). Return for DC-OK signal output. DC-OK DC-OK signal is a TTL level signal, referenced to pin8(DC-OK GND). High when PSU turns on. Positive sensing. The +S signal should be connected to the positive terminal of the load. The +S and -S leads should be twisted in pair to +S minimize noise pick-up effect. The maximum line drop compensation is 0.5V. -S Negative sensing. The -S signal should be connected to the negative terminal of the load. The -S and +S leads should be twisted in pair to minimize noise pick-up effect. The maximum line drop compensation is 0.5V. Function Manual 1.Remote Sense The remote sensing compensates voltage drop on the load wiring up to 0.5V. CN100 CN100 2 1 10 9 2 AUX AUXG 1 RC- RC+ GND CS GND DC-OK 10 +S (Pin9) - + LOAD -S +S 9 -S (Pin10) Sense lines should be twisted in pairs Fig 1.1 2.DC-OK Signal DC-OK signal is a TTL level signal. High when PSU turns on. CN100 Between DC-OK(pin7) and GND(pin6,8) Output Status CN100 3.3 ~ 5.6V ON 2 1 0 ~ 1V OFF 10 9 2 AUX AUXG 1 RC- RC+ GND CS GND DC-OK 10 -S +S 9 Fig 2.1 File Name:MSP-600-SPEC 2018- 01-15 MSP-600 600W Single Output Medical Type 3.Remote Control The PSU can be turned ON/OFF by using the "Remote Control" function. CN100 CN100 Output Status Between RC+(pin3) and RC-(pin4) SW ON (Short) OFF SW OFF (Open) ON series 2 1 10 9 2 AUX AUXG 1 RC- RC+ GND CS GND DC-OK 10 -S +S 9 SW Fig 3.1 4.Current Sharing with Remote Sensing (Only for 24V, 36V and 48V) MSP-600 has the built-in active current sharing function and can be connected in parallel to provide higher output power : (1)Parallel operation is available by connecting the units shown as below. (+S,-S,CS and GND are connected mutually in parallel). (2)Difference of output voltages among parallel units should be less than 2%. (3)The total output current must not exceed the value determined by the following equation. (output current at parallel operation)=(Rated current per unit)x(Number of unit)x0.9 (4)In parallel operation 4 units is the maximum, please consult the manufacturer for applications of more connecting in parallel. (5)The power supplies should be paralleled using short and large diameter wiring and then connected to the load. PSU1 PSU2 PSU3 -V PSU4 -V +V -V +V CN100 -V +V CN100 +V CN100 CN100 PSU1 PSU2 PSU3 PSU4 CN100 CN100 CN100 CN100 1 AUXG RC+ CS DC-OK +S 2 AUX RC- GND GND -S 9 1 AUXG RC+ CS DC-OK +S 10 2 AUX RC- GND GND -S 9 1 AUXG RC+ 10 2 AUX RC- GND GND +V -V CS DC-OK +S -S 9 1 AUXG RC+ CS DC-OK +S 10 2 AUX RC- GND GND -S 9 10 Sense lines should be twisted in pairs LOAD Fig 4.1 Note : 1.In parallel connection, maybe only one unit (master) operate if the total output load is less than 2% of rated load condition. The other PSU (slave) may go into standby mode and its output LED and relay will not turn on. 2.2% min. of dummy load is required. File Name:MSP-600-SPEC 2018- 01-15