___________________ Introduction Fundamental safety 1 ___________________ instructions SIMOTICS Drive technology 1PH8 main motors Configuration Manual 2 ___________________ Motor description 3 ___________________ Mechanical properties Motor components and 4 ___________________ options 5 ___________________ Configuration Technical data and 6 ___________________ characteristics 7 ___________________ Preparing for use 8 ___________________ Electrical connection 9 ___________________ Dimension drawings A ___________________ Appendix 12/2016 6SN1197-0AD74-0BP2 Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION indicates that minor personal injury can result if proper precautions are not taken. NOTICE indicates that property damage can result if proper precautions are not taken. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems. Proper use of Siemens products Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed. Trademarks All names identified by (R) are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Siemens AG Division Digital Factory Postfach 48 48 90026 NURNBERG GERMANY Document order number: 6SN1197-0AD74-0BP2 03/2017 Subject to change Copyright (c) Siemens AG 2010 - 2016. All rights reserved Introduction Standard version This documentation only describes the functionality of the standard version. The machine OEM documents any extensions or changes to the motor made by it. For reasons of clarity, this documentation cannot contain all of the detailed information on all of the product types. Moreover, this documentation cannot take into consideration every possible type of installation, operation, and maintenance. This documentation should be kept in a location where it can be easily accessed and made available to the personnel responsible. Target group This documentation addresses project planners and project engineers as well as machine manufacturers and commissioning engineers. Benefits The Configuration Manual enables the target group to apply the rules and guidelines to be observed when configuring products and systems. The Configuration Manual supports you with selecting motors, calculating the drive components, and selecting the required accessories. The Configuration Manual helps the target group to create a system or plant configuration. Utilization phase Planning and configuration phase Text features In addition to the notes that you must observe for your own personal safety as well as to avoid material damage, in this document you will find the following text features: Operating instructions Operating instructions with the specified sequence are designated using the following symbols: The arrow indicates the start of the operating instructions. The individual handling steps are numbered. 1. Execute the operating instructions in the specified sequence. The square indicates the end of the operating instruction. 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 5 Introduction Operating instructions without a specified sequence are identified using a bullet point: Execute the operating instructions. Enumerations Enumerations are identified by a bullet point without any additional symbols. - Enumerations at the second level are hyphenated. Notes Notes are shown as follows: Note A Note is an important item of information about the product, handling of the product or the relevant section of the document. Notes provide you with help or further suggestions/ideas. More information Information on the following topics is available under the link: Ordering documentation/overview of documentation Additional links to download documents Using documentation online (find and search in manuals/information) More information (https://support.industry.siemens.com/cs/de/en/view/108998034) Please send any questions about the technical documentation (e.g. suggestions for improvement, corrections) to the following e-mail address: docu.motioncontrol@siemens.com Any manuals or operating instructions that you may have in printed or electronic file form could be of an older product version. Internet address for products Products (http://www.siemens.com/motioncontrol) My support The following link provides information on how to create your own individual documentation based on Siemens content, and adapt it for your own machine documentation: 1PH8 main motors 6 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Introduction My support (https://support.industry.siemens.com/My/de/en/documentation) Note If you want to use this function, you must first register. Later, you can log on with your login data. Training The following link provides information on SITRAIN - training from Siemens for products, systems and automation engineering solutions: SITRAIN (http://siemens.com/sitrain) Technical Support Country-specific telephone numbers for technical support are provided on the Internet under Contact: Technical Support (https://support.industry.siemens.com) Websites of third parties This publication contains hyperlinks to websites of third parties. Siemens does not take any responsibility for the contents of these websites or adopt any of these websites or their contents as their own, because Siemens does not control the information on these websites and is also not responsible for the contents and information provided there. Use of these websites is at the risk of the person doing so. Information regarding third-party products Note Recommendation relating to third-party products This document contains recommendations relating to third-party products. Siemens accepts the fundamental suitability of these third-party products. You can use equivalent products from other manufacturers. Siemens does not accept any warranty for the properties of third-party products. 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 7 Introduction 1PH8 main motors 8 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Table of contents Introduction ............................................................................................................................................. 5 1 2 3 Fundamental safety instructions ............................................................................................................ 13 1.1 General safety instructions .....................................................................................................13 1.2 Handling electrostatic sensitive devices (ESD) ......................................................................18 1.3 Industrial security ....................................................................................................................19 1.4 Residual risks of power drive systems....................................................................................20 Motor description .................................................................................................................................. 23 2.1 Highlights and benefits............................................................................................................23 2.2 Use for the intended purpose .................................................................................................25 2.3 2.3.1 2.3.2 2.3.3 Technical characteristics and environmental conditions ........................................................27 Directives and standards ........................................................................................................27 Technical features ...................................................................................................................28 Classifying environmental conditions according to climate classes .......................................32 2.4 2.4.1 Derating factors .......................................................................................................................34 Reduction of the max. DC-link voltage ...................................................................................34 2.5 2.5.1 2.5.2 2.5.3 2.5.4 2.5.5 2.5.6 2.5.7 Selection and ordering data ....................................................................................................36 Article No. suffixes for shaft height 80 to 160 .........................................................................36 Article No. suffixes for SH 80 Premium Performance .............................................................40 Article No. suffixes for SH 180 to 280 .....................................................................................42 Article No. suffixes for SH 280 ................................................................................................45 Article No. suffix for SH80 to 160 + holding brake DE ............................................................48 Article No. suffix for SH180 to 225 + holding brake ................................................................50 Options ....................................................................................................................................53 2.6 Nameplate data (rating plate) .................................................................................................60 Mechanical properties ........................................................................................................................... 63 3.1 3.1.1 3.1.2 3.1.3 Cooling ....................................................................................................................................63 General ...................................................................................................................................63 Forced ventilation....................................................................................................................63 Water cooling ..........................................................................................................................67 3.2 Degree of protection ...............................................................................................................80 3.3 Construction types ..................................................................................................................82 3.4 3.4.1 3.4.2 3.4.3 Types of bearing .....................................................................................................................83 Drive output types and bearing versions ................................................................................83 Bearing lifetime .......................................................................................................................88 NDE bearings, insulated version (option L27) ........................................................................91 3.5 Shaft end .................................................................................................................................94 3.6 Mounting of rotating unions on 1PH8 hollow-shaft motors .....................................................94 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 9 Table of contents 4 3.6.1 3.6.2 3.6.3 3.6.4 Rotor-supported rotating union .............................................................................................. 97 Bearingless, frame-supported rotating union ....................................................................... 101 Mounting information and instructions ................................................................................. 107 Suggestion for an adapter for bearingless, frame-supported rotating unions ..................... 109 3.7 3.7.1 3.7.2 3.7.3 3.7.4 Radial and axial forces ......................................................................................................... 110 Radial force .......................................................................................................................... 110 Axial force ............................................................................................................................ 112 Permissible radial and axial forces for 1PH808 Premium Performance .............................. 114 Radial and axial force diagrams........................................................................................... 114 3.8 Radial eccentricity, concentricity and axial eccentricity ....................................................... 139 3.9 3.9.1 3.9.2 Balancing ............................................................................................................................. 140 Requirements ....................................................................................................................... 140 Balancing 1PH8 motors with "Premium Performance" bearing version .............................. 142 3.10 3.10.1 3.10.2 3.10.3 3.10.4 3.10.5 Vibration response ............................................................................................................... 147 Mounting and mounting instructions .................................................................................... 147 Natural frequency when mounted ........................................................................................ 149 Misalignment ........................................................................................................................ 150 Flywheels ............................................................................................................................. 151 Vibration stressing ............................................................................................................... 152 3.11 Vibration severity grade ....................................................................................................... 155 3.12 Noise emission ..................................................................................................................... 157 Motor components and options ............................................................................................................159 4.1 4.1.1 4.1.2 4.1.2.1 4.1.2.2 4.1.2.3 4.1.2.4 4.1.2.5 4.1.2.6 4.1.2.7 4.1.2.8 Motor components ............................................................................................................... 159 Thermal motor protection ..................................................................................................... 159 Encoder ................................................................................................................................ 161 Encoder overview................................................................................................................. 161 Encoder connection for motors with a DRIVE-CLiQ interface ............................................. 162 Encoder connection for motors without DRIVE-CLiQ (12/17-pole) ..................................... 162 Encoder assignment as a function of maximum permissible speeds .................................. 163 Incremental encoder HTL 1024 S/R or HTL 2048 S/R ........................................................ 166 Incremental encoder HTL for operation on SINAMICS G .................................................... 168 Incremental encoders IC 2048 S/R, IN 512 S/R and IN 256 S/R ........................................ 169 Absolute encoder AM 2048 S/R........................................................................................... 172 4.2 4.2.1 4.2.2 4.2.3 4.2.4 4.2.5 4.2.5.1 4.2.5.2 4.2.5.3 4.2.6 4.2.7 4.2.8 4.2.9 4.2.10 Options ................................................................................................................................. 174 Overview of options ............................................................................................................. 174 Sealing air connection (option Q12)..................................................................................... 174 Protection against explosion (options M03 and M39) .......................................................... 176 Increased resistance to vibration (option L03) ..................................................................... 182 Holding brake (option) .......................................................................................................... 184 Properties ............................................................................................................................. 184 Mounted holding brake for SH 80 to SH 160 ....................................................................... 188 Mounted holding brake for SH 180 and SH 225 .................................................................. 198 Anti-condensation heating (option K45) ............................................................................... 202 Condensation drain hole (option L12) .................................................................................. 202 Extra grounding terminals in terminal box (Q00) ................................................................. 204 Three-phase external fan (option L75) ................................................................................ 205 Chain of PTC thermistors for alarm and trip (option A12) ................................................... 206 1PH8 main motors 10 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Table of contents 5 6 Configuration ...................................................................................................................................... 209 5.1 5.1.1 Configuring software .............................................................................................................209 SIZER configuration tool .......................................................................................................209 5.2 5.2.1 5.2.2 5.2.3 5.2.4 Procedure when engineering ................................................................................................211 SINAMICS configuring procedure .........................................................................................211 Specifying the duty cycle ......................................................................................................213 Selecting induction motors ....................................................................................................216 Selecting synchronous motors ..............................................................................................218 5.3 Different rated points for induction motors ............................................................................219 5.4 Configuration for SINAMICS G .............................................................................................222 5.5 Configuration for 1PH808 Premium Performance ................................................................223 Technical data and characteristics ...................................................................................................... 225 6.1 6.1.1 6.1.1.1 6.1.1.2 6.1.1.3 6.1.1.4 6.1.1.5 6.1.1.6 6.1.1.7 6.1.1.8 6.1.1.9 6.1.1.10 6.1.1.11 6.1.1.12 6.1.1.13 6.1.1.14 6.1.1.15 6.1.1.16 6.1.1.17 6.1.1.18 6.1.1.19 6.1.2 6.1.2.1 6.1.2.2 6.1.2.3 6.1.2.4 6.1.2.5 6.1.2.6 6.1.2.7 6.1.2.8 6.1.2.9 6.1.2.10 6.1.2.11 6.1.3 6.1.3.1 6.1.3.2 6.1.3.3 Induction motors ...................................................................................................................225 Technical data .......................................................................................................................225 Shaft height 80 - forced ventilation .......................................................................................226 Shaft height 100 - forced ventilation.....................................................................................227 Shaft height 132 - forced ventilation.....................................................................................229 Shaft height 160 - forced ventilation .....................................................................................231 Shaft height 180 - forced ventilation .....................................................................................232 Shaft height 180 - forced ventilation (open-circuit ventilation) ..............................................233 Shaft height 225 - forced ventilation .....................................................................................234 Shaft height 225 - forced ventilation (open-circuit ventilation) ..............................................235 Shaft height 280 - forced ventilation .....................................................................................237 Shaft height 280 - forced ventilation (open-circuit ventilation) ..............................................239 Overload factors for intermittent duty types (S6) and short-time duty (S2) ..........................240 Shaft height 80 - water-cooled ..............................................................................................241 Shaft height 100 - water-cooled ............................................................................................242 Shaft height 132 - water-cooled ............................................................................................243 Shaft height 160 - water cooling ...........................................................................................244 Shaft height 180 - water-cooled ............................................................................................245 Shaft height 225 - water-cooled ............................................................................................246 Shaft height 280 - water-cooled ............................................................................................247 Overload factors for intermittent duty types (S6) and short-time duty (S2) ..........................249 Characteristics forced ventilation ..........................................................................................250 Shaft height 80 - forced ventilation .......................................................................................250 Shaft height 80 - forced ventilation - Premium Performance ................................................282 Shaft height 100 - forced ventilation.....................................................................................307 Shaft height 132 - forced ventilation.....................................................................................375 Shaft height 160 - forced ventilation .....................................................................................455 Shaft height 180 - forced ventilation .....................................................................................487 Shaft height 180 - forced ventilation (open-circuit ventilation) ..............................................525 Shaft height 225 - forced ventilation .....................................................................................563 Shaft height 225 - forced ventilation (open-circuit ventilation) ..............................................620 Shaft height 280 - forced ventilation .....................................................................................677 Shaft height 280 - forced ventilation (open-circuit ventilation) ..............................................749 Characteristics water cooling ................................................................................................803 Shaft height 80 - water-cooled ..............................................................................................803 Shaft height 80 - Water cooling - Premium Performance ....................................................827 Shaft height 100 - water-cooled ............................................................................................856 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 11 Table of contents 6.1.3.4 6.1.3.5 6.1.3.6 6.1.3.7 6.1.3.8 Shaft height 132 - water-cooled ........................................................................................... 896 Shaft height 160 - water cooling .......................................................................................... 928 Shaft height 180 - water-cooled ........................................................................................... 952 Shaft height 225 - water-cooled ........................................................................................... 982 Shaft height 280 - water-cooled ......................................................................................... 1027 6.2 6.2.1 6.2.1.1 6.2.1.2 6.2.1.3 6.2.1.4 6.2.1.5 6.2.1.6 6.2.1.7 6.2.1.8 6.2.1.9 6.2.1.10 6.2.2 6.2.2.1 6.2.2.2 6.2.2.3 6.2.2.4 6.2.3 6.2.3.1 6.2.3.2 6.2.3.3 6.2.3.4 Synchronous motors .......................................................................................................... 1087 Technical data .................................................................................................................... 1087 Shaft height 132 - forced ventilation .................................................................................. 1088 Shaft height 160 - forced ventilation .................................................................................. 1088 Shaft height 180 - forced ventilation .................................................................................. 1089 Shaft height 225 - forced ventilation .................................................................................. 1089 Overload factors for intermittent duty types (S6) and short-time duty (S2) ....................... 1090 Shaft height 132 - water-cooled ......................................................................................... 1091 Shaft height 160 - water cooling ........................................................................................ 1092 Shaft height 180 - water-cooled ......................................................................................... 1092 Shaft height 225 - water-cooled ......................................................................................... 1093 Overload factors for intermittent duty types (S6) and short-time duty (S2) ....................... 1094 Characteristics forced ventilation ....................................................................................... 1095 Shaft height 132 - forced ventilation .................................................................................. 1095 Shaft height 160 - forced ventilation .................................................................................. 1122 Shaft height 180 - forced ventilation .................................................................................. 1134 Shaft height 225 - forced ventilation .................................................................................. 1152 Characteristics water cooling ............................................................................................. 1179 Shaft height 132 - water-cooled ......................................................................................... 1179 Shaft height 160 - water cooling ........................................................................................ 1209 Shaft height 180 - water-cooled ......................................................................................... 1227 Shaft height 225 - water-cooled ......................................................................................... 1251 7 Preparing for use ............................................................................................................................... 1287 8 Electrical connection .......................................................................................................................... 1291 8.1 Permissible line system configurations .............................................................................. 1291 8.2 Circuit diagram of the motor ............................................................................................... 1292 8.3 8.3.1 8.3.2 8.3.3 8.3.4 8.3.5 8.3.6 System integration ............................................................................................................. 1293 SINAMICS drive I/O ........................................................................................................... 1293 Connecting-up information ................................................................................................. 1294 Routing cables in a damp environment ............................................................................. 1296 Power connection............................................................................................................... 1297 External fan ........................................................................................................................ 1313 Signal connection ............................................................................................................... 1326 9 Dimension drawings ........................................................................................................................... 1329 A Appendix ........................................................................................................................................... 1331 A.1 Description of terms ........................................................................................................... 1331 A.2 Environmental compatibility ............................................................................................... 1334 Index ................................................................................................................................................. 1335 1PH8 main motors 12 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Fundamental safety instructions 1.1 1 General safety instructions DANGER Danger to life due to live parts and other energy sources Death or serious injury can result when live parts are touched. * Only work on electrical devices when you are qualified for this job. * Always observe the country-specific safety rules. Generally, six steps apply when establishing safety: 1. Prepare for shutdown and notify all those who will be affected by the procedure. 2. Disconnect the machine from the supply. - Switch off the machine. - Wait until the discharge time specified on the warning labels has elapsed. - Check that it really is in a no-voltage condition, from phase conductor to phase conductor and phase conductor to protective conductor. - Check whether the existing auxiliary supply circuits are de-energized. - Ensure that the motors cannot move. 3. Identify all other dangerous energy sources, e.g. compressed air, hydraulic systems, or water. 4. Isolate or neutralize all hazardous energy sources by closing switches, grounding or short-circuiting or closing valves, for example. 5. Secure the energy sources against switching on again. 6. Ensure that the correct machine is completely interlocked. After you have completed the work, restore the operational readiness in the inverse sequence. WARNING Danger to life through a hazardous voltage when connecting an unsuitable power supply Touching live components can result in death or severe injury. * Only use power supplies that provide SELV (Safety Extra Low Voltage) or PELV(Protective Extra Low Voltage) output voltages for all connections and terminals of the electronics modules. 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 13 Fundamental safety instructions 1.1 General safety instructions WARNING Danger to life when live parts are touched on damaged motors/devices Improper handling of motors/devices can damage them. For damaged motors/devices, hazardous voltages can be present at the enclosure or at exposed components. * Ensure compliance with the limit values specified in the technical data during transport, storage and operation. * Do not use any damaged motors/devices. WARNING Danger to life through electric shock due to unconnected cable shields Hazardous touch voltages can occur through capacitive cross-coupling due to unconnected cable shields. * As a minimum, connect cable shields and the conductors of power cables that are not used (e.g. brake cores) at one end at the grounded housing potential. WARNING Danger to life due to electric shock when not grounded For missing or incorrectly implemented protective conductor connection for devices with protection class I, high voltages can be present at open, exposed parts, which when touched, can result in death or severe injury. * Ground the device in compliance with the applicable regulations. WARNING Danger to life due to electric shock when opening plug connections in operation When opening plug connections in operation, arcs can result in severe injury or death. * Only open plug connections when the equipment is in a no-voltage state, unless it has been explicitly stated that they can be opened in operation. NOTICE Material damage due to loose power connections Insufficient tightening torques or vibrations can result in loose electrical connections. This can result in damage due to fire, device defects or malfunctions. * Tighten all power connections with the specified tightening torques, e.g. line supply connection, motor connection, DC link connections. * Check all power connections at regular intervals. This applies in particular after transport. 1PH8 main motors 14 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Fundamental safety instructions 1.1 General safety instructions WARNING Danger to life through unexpected movement of machines when using mobile wireless devices or mobile phones Using mobile wireless devices or mobile phones with a transmit power > 1 W closer than approx. 2 m to the components may cause the devices to malfunction, influence the functional safety of machines therefore putting people at risk or causing material damage. * Switch the wireless devices or mobile phones off in the immediate vicinity of the components. WARNING Danger of an accident occurring due to missing or illegible warning labels Missing or illegible warning labels can result in accidents involving death or serious injury. * Check that the warning labels are complete based on the documentation. * Attach any missing warning labels to the components, in the national language if necessary. * Replace illegible warning labels. WARNING Danger to life when safety functions are inactive Safety functions that are inactive or that have not been adjusted accordingly can cause operational faults on machines that could lead to serious injury or death. * Observe the information in the appropriate product documentation before commissioning. * Carry out a safety inspection for functions relevant to safety on the entire system, including all safety-related components. * Ensure that the safety functions used in your drives and automation tasks are adjusted and activated through appropriate parameterizing. * Perform a function test. * Only put your plant into live operation once you have guaranteed that the functions relevant to safety are running correctly. Note Important safety notices for Safety Integrated functions If you want to use Safety Integrated functions, you must observe the safety notices in the Safety Integrated manuals. 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 15 Fundamental safety instructions 1.1 General safety instructions WARNING Danger to life from electromagnetic fields Electromagnetic fields (EMF) are generated by the operation of electrical power equipment, such as transformers, converters, or motors. People with pacemakers or implants are at particular risk in the immediate vicinity of this equipment. * If you have a heart pacemaker or implant, maintain the minimum distance specified in chapter "Correct usage" from such motors. WARNING Danger to life from permanent-magnet fields Even when switched off, electric motors with permanent magnets represent a potential risk for persons with heart pacemakers or implants if they are close to converters/motors. * If you have a heart pacemaker or implant, maintain the minimum distance specified in chapter "Correct usage". * When transporting or storing permanent-magnet motors always use the original packing materials with the warning labels attached. * Clearly mark the storage locations with the appropriate warning labels. * IATA regulations must be observed when transported by air. WARNING Risk of injury caused by moving parts or parts that are flung out Touching moving motor parts or drive output elements and loose motor parts that are flung out (e.g. feather keys) in operation can result in severe injury or death. * Remove any loose parts or secure them so that they cannot be flung out. * Do not touch any moving parts. * Safeguard all moving parts using the appropriate safety guards. WARNING Danger to life due to fire if overheating occurs because of insufficient cooling Inadequate cooling can cause overheating resulting in death or severe injury as a result of smoke and fire. This can also result in increased failures and reduced service lives of motors. * Comply with the specified coolant requirements for the motor. WARNING 1PH8 main motors 16 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Fundamental safety instructions 1.1 General safety instructions Danger to life due to fire as a result of overheating caused by incorrect operation When incorrectly operated and in the case of a fault, the motor can overheat resulting in fire and smoke. This can result in severe injury or death. Further, excessively high temperatures destroy motor components and result in increased failures as well as shorter service lives of motors. * Operate the motor according to the relevant specifications. * Only operate the motors in conjunction with effective temperature monitoring. * Immediately switch off the motor if excessively high temperatures occur. CAUTION Risk of injury due to touching hot surfaces In operation, the motor can reach high temperatures, which can cause burns if touched. * Mount the motor so that it is not accessible in operation. Measures when maintenance is required: * Allow the motor to cool down before starting any work. * Use the appropriate personnel protection equipment, e.g. gloves. 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 17 Fundamental safety instructions 1.2 Handling electrostatic sensitive devices (ESD) 1.2 Handling electrostatic sensitive devices (ESD) Electrostatic sensitive devices (ESD) are individual components, integrated circuits, modules or devices that may be damaged by either electric fields or electrostatic discharge. NOTICE Damage through electric fields or electrostatic discharge Electric fields or electrostatic discharge can cause malfunctions through damaged individual components, integrated circuits, modules or devices. * Only pack, store, transport and send electronic components, modules or devices in their original packaging or in other suitable materials, e.g conductive foam rubber of aluminum foil. * Only touch components, modules and devices when you are grounded by one of the following methods: - Wearing an ESD wrist strap - Wearing ESD shoes or ESD grounding straps in ESD areas with conductive flooring * Only place electronic components, modules or devices on conductive surfaces (table with ESD surface, conductive ESD foam, ESD packaging, ESD transport container). 1PH8 main motors 18 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Fundamental safety instructions 1.3 Industrial security 1.3 Industrial security Note Industrial security Siemens provides products and solutions with industrial security functions that support the secure operation of plants, systems, machines and networks. In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement - and continuously maintain - a holistic, state-of-the-art industrial security concept. Siemens products and solutions only represent one component of such a concept. The customer is responsible for preventing unauthorized access to its plants, systems, machines and networks. Systems, machines and components should only be connected to the enterprise network or the internet if and to the extent necessary and with appropriate security measures (e.g. use of firewalls and network segmentation) in place. Additionally, Siemens' guidance on appropriate security measures should be taken into account. For more information about industrial security, please visit: Industrial security (http://www.siemens.com/industrialsecurity). Siemens' products and solutions undergo continuous development to make them more secure. Siemens strongly recommends to apply product updates as soon as available and to always use the latest product versions. Use of product versions that are no longer supported, and failure to apply latest updates may increase customer's exposure to cyber threats. To stay informed about product updates, subscribe to the Siemens Industrial Security RSS Feed at: Industrial security (http://www.siemens.com/industrialsecurity). WARNING Danger to life as a result of unsafe operating states resulting from software manipulation Software manipulations (e.g. viruses, trojans, malware or worms) can cause unsafe operating states in your system that may lead to death, serious injury, and property damage. * Keep the software up to date. * Incorporate the automation and drive components into a holistic, state-of-the-art industrial security concept for the installation or machine. * Make sure that you include all installed products into the holistic industrial security concept. * Protect files stored on exchangeable storage media from malicious software by with suitable protection measures, e.g. virus scanners. 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 19 Fundamental safety instructions 1.4 Residual risks of power drive systems 1.4 Residual risks of power drive systems When assessing the machine- or system-related risk in accordance with the respective local regulations (e.g., EC Machinery Directive), the machine manufacturer or system installer must take into account the following residual risks emanating from the control and drive components of a drive system: 1. Unintentional movements of driven machine or system components during commissioning, operation, maintenance, and repairs caused by, for example, - Hardware and/or software errors in the sensors, control system, actuators, and cables and connections - Response times of the control system and of the drive - Operation and/or environmental conditions outside the specification - Condensation/conductive contamination - Parameterization, programming, cabling, and installation errors - Use of wireless devices/mobile phones in the immediate vicinity of electronic components - External influences/damage - X-ray, ionizing radiation and cosmic radiation 2. Unusually high temperatures, including open flames, as well as emissions of light, noise, particles, gases, etc., can occur inside and outside the components under fault conditions caused by, for example: - Component failure - Software errors - Operation and/or environmental conditions outside the specification - External influences/damage 3. Hazardous shock voltages caused by, for example: - Component failure - Influence during electrostatic charging - Induction of voltages in moving motors - Operation and/or environmental conditions outside the specification - Condensation/conductive contamination - External influences/damage 4. Electrical, magnetic and electromagnetic fields generated in operation that can pose a risk to people with a pacemaker, implants or metal replacement joints, etc., if they are too close 5. Release of environmental pollutants or emissions as a result of improper operation of the system and/or failure to dispose of components safely and correctly 6. Influence of network-connected communication systems, e.g. ripple-control transmitters or data communication via the network 1PH8 main motors 20 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Fundamental safety instructions 1.4 Residual risks of power drive systems For more information about the residual risks of the drive system components, see the relevant sections in the technical user documentation. 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 21 Fundamental safety instructions 1.4 Residual risks of power drive systems 1PH8 main motors 22 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 2 Motor description 2.1 Highlights and benefits Overview The SIMOTICS M-1PH8 motor series, referred to as 1PH8 in the following, is a motor generation developed for universal implementation in plants and machines with motion control applications. The motors are available as an asynchronous variant as well as a compact synchronous variant with either forced ventilation or water cooling, based on a flexible building block principle. In comparison to the freely selectable performance of vector and servo control with the SINAMICS S120 drive system, it is possible to select between asynchronous or synchronous variants in the case of the SIMOTICS M-1PH8 motor series. Thanks to this flexible interplay between converter and motor, it is now even easier to implement applications which involve extreme duty cycles, short rise times, high precision with respect to speed, torque and positioning. The motors have been designed specifically for use in conjunction with the SINAMICS S120 drive system. Depending on the control requirements, appropriate encoder systems are available for the motors for sensing the motor speed and indirect position. Encoder systems for C-axis operation are also available for machine tools. 1PH8 motors are available in two different cooling types: Forced ventilation Water cooling SH 80 to SH 160 Forced ventilation SH 80 to SH 160 Water cooling SH 180 to SH 280 Water cooling 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 23 Motor description 2.1 Highlights and benefits SH 180 to SH 225 Forced ventilation SH 280 Forced ventilation Highlights and benefits Wide power spectrum with low envelope dimensions Wide speed control ranges High degree of flexibility due to the choice of - Asynchronous or synchronous design - Forced ventilation or water cooling - Solid or hollow shaft - Various bearing concepts - Different encoder types for speed control and precision positioning Outstanding performance characteristics - Maximum speeds up to 24,000 rpm - Minimal torque oscillations up to 10 m - Excellent vibration magnitudes - High dynamic response (short ramp-up times) Low noise emission Simple and flexible connection system Commissioning with electronic type plate and DRIVE-CLiQ interface 1PH8 main motors 24 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Motor description 2.2 Use for the intended purpose 2.2 Use for the intended purpose WARNING Danger to life and material damage when incorrectly used If you do not use the motors or their components correctly, there is a risk of death, severe injury and/or material damage. * Only use the motors for industrial or commercial plants and systems. * If, in an exceptional case, you do not use the motors in industrial or commercial plants and systems, ensure that increased requirements are complied with (e.g. regarding touch protection). * Do not use the motors in hazardous areas (where there is a risk of explosion), if the motors have not been expressly released and authorized for these types of applications. Carefully observe any special supplementary notes that may be attached. * Only use the motors and their components for the applications specified by Siemens. * Protect the motors against dirt and contact with aggressive substances. * Ensure that the site conditions comply with the rating plate data and the conditions specified in this documentation. When necessary, take into account deviations regarding approvals or country-specific regulations. * If you have any questions regarding the intended use, please contact your local Siemens office. * If you wish to use special versions and design variants whose specifications vary from the motors described in this document, then first contact your local Siemens office. WARNING Danger to life for wearers of active implants due to magnetic and electrical fields Electric motors pose a danger to people with active medical implants, e.g. cardiac stimulators, who come close to the motors. * If you are affected, stay at a minimum distance of 500 mm from the motors (tripping threshold for static magnetic fields of 0.5 mT according to the Directive 2013/35/EU). The motors are designed for use in covered areas, such as production areas (see Chapter Environmental conditions (Page 32)) The 1PH8 three-phase motors are used as industrial drives for machine tools and production machines. Thanks to integrated technology, 1PH8 motors can be used in a very wide variety of applications in conjunction with the SINAMICS drive system: Compact machine tools Complex machining centers and lathes 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 25 Motor description 2.2 Use for the intended purpose Milling machines with full enclosure High-load milling spindles Counterspindles or power tools for turning machines Direct power tools with internal cooling Main drives in presses and extruders, converting applications Rotary axes in the paper and printing industry For use in crane systems (power house) Flying shears, coilers and winder drives Customized machines 1PH8 main motors 26 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Motor description 2.3 Technical characteristics and environmental conditions 2.3 Technical characteristics and environmental conditions 2.3.1 Directives and standards Standards that are complied with SIMOTICS S, SIMOTICS M, SIMOTICS L, SIMOTICS T, SIMOTICS A motors subsequently called the "SIMOTICS motor series " - comply with the following standards: EN 60034-1 - Rotating electrical machines - Dimensioning and operating behavior EN 60204-1 - Safety of machinery - Electrical equipment of machines; general requirements Where applicable, the SIMOTICS motor series are in conformance with the following parts of IEC / EN 60034: Feature Standard Degree of protection 1) IEC / EN 60034-5 Cooling IEC / EN 60034-6 2) Type of construction IEC / EN 60034-7 1) Connection designations IEC / EN 60034-8 Noise levels IEC / EN 60034-9 2) Temperature monitoring Vibration severity levels IEC / EN 60034-11 2) IEC / EN 60034-14 1) The degree of protection and type of construction of the motor are stamped on its rating plate. 2) Standard component, e.g. cannot be applied to built-in motors Relevant directives The following directives are relevant for SIMOTICS motors. European Low-Voltage Directive SIMOTICS motors comply with the Low-Voltage Directive 2014/35/EU. European Machinery Directive SIMOTICS motors do not fall within the area of validity covered by the Machinery Directive. However, the use of the products in a typical machine application has been fully assessed for compliance with the main regulations in this directive concerning health and safety. European EMC Directive SIMOTICS motors do not fall within the area of validity covered by the EMC Directive. The products are not considered as devices in the sense of the directive. 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 27 Motor description 2.3 Technical characteristics and environmental conditions Eurasian conformity SIMOTICS motors comply with the requirements of the customs union Russia/Belarus/Kazakhstan (EAC). China Compulsory Certification SIMOTICS motors do not fall within the area of validity covered by the China Compulsory Certification (CCC). CCC product certification (https://support.industry.siemens.com/cs/products?search=CCC&dtp=Certificate&o=Default RankingDesc&pnid=13347&lc=de-WW // XmlEditor.InternalXmlClipboard:65c36f4c-2e8cd8c9-ae3f-9d6074d36b88) Underwriters Laboratories SIMOTICS motors are generally in compliance with UL and cUL as components of motor applications, and are appropriately listed. Specifically developed motors and functions are the exceptions in this case. Here, it is important that you carefully observe the contents of the quotation and that there is a cUL mark on the rating plate (type plate)! Quality systems Siemens AG employs a quality management system that meets the requirements of ISO 9001 and ISO 14001. Certificates for SIMOTICS motors can be downloaded from the Internet at the following link: Certificates for SIMOTICS motors (https://support.industry.siemens.com/cs/products?dtp=Certificate&pnid=13347&lc=de-WW // XmlEditor.InternalXmlClipboard:8c9b08a9-3f1f-5513-8cf9-8dce082595ac) 2.3.2 Technical features The technical features specified in the tables below refer to the basic model of the 1PH8 motor and apply to the asynchronous and synchronous variants. Depending on the electrical and mechanical configuration, it is possible to add options to the basic model in order to adapt it to a specific drive application (refer to Options, Selection and Ordering data). Table 2- 1 Forced ventilation Insulation of the stator winding in accordance with EN 60034-1 (IEC 60034-1) For an ambient temperature of up to 40 C SH 80 to SH 280 temperature class 180 (H) Cooling in accordance with EN 60034-6 (IEC 60034-6) Forced ventilation SH 80 ... SH 225: Fan mounted axially at NDE SH 280: Fan mounted radially at NDE Temperature monitoring Temperature sensor in the stator winding SH 180 ... SH 280: Additional temperature sensor as a standby 1PH8 main motors 28 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Motor description 2.3 Technical characteristics and environmental conditions Fan supply voltage (see "Technical data") SH 80: SH 100 ... SH 160: SH 180 ... SH 225: SH 280: 1-ph. 230 VAC, 50/60 Hz, 1-ph. 265 VAC, 60 Hz 3-ph. 400 VAC, 50/60 Hz, 3-ph. 480 VAC, 60 Hz 1-ph. 200 to 277 VAC, 50/60 Hz (EC fan) 3-ph. 400 VAC, 50/60 Hz, 3-ph. 480 VAC 60 Hz Type in accordance with EN 60034-7 (IEC 60034-7) SH 80: SH 100 ... SH 280: IM B3, IM B5 IM B3, IM B5, IM B35 Degree of protection in accordance with EN 60034-5 (IEC 60034-5) SH 80 ... SH 280: SH 180 ... SH 280: IP55 IP23 Shaft extension at the drive end (DE) in accordance with DIN 748-3 (IEC 60072-1) Plain shaft or feather key, full-key or half-key balancing for feather key Shaft and flange accuracy in accordance with DIN 42955 (IEC 60072-1)1) SH 80 ... SH 160 :SH 180 ... SH 280: Tolerance R (reduced), SPECIAL2) Tolerance N (normal) Vibration magnitudes in accordance with Siemens / EN 60034-14 (IEC 60034-14) SH 80 ... SH 160: Level R/A, SPECIAL/B Level A Sound pressure level in accordance with DIN EN ISO 1680, max. tolerance +3 dB, external fan 50 Hz SH 180 ... SH 280: SH 80 ... SH 132: 70 dB at a rated pulse frequency of 4 kHz and a speed range up to 5000 rpm SH 160: 73 dB at a rated pulse frequency of 4 kHz and a speed range up to 5000 rpm SH 180 and SH 225: 73 dB at a rated pulse frequency of 2 kHz and a speed range: Forced ventilation (IP55) * SH180 up to 5000 rpm * SH225 up to 3500 rpm Open-circuit ventilation (IP23) SH 280 * SH180 up to 3000 rpm * SH225 up to 2000 rpm 74 dB at a rated pulse frequency of 2 kHz and a speed range: Up to 3300 rpm Forced ventilation (IP55) * SH280 up to 3300 rpm Open-circuit ventilation (IP23) * SH280 up to 2800 rpm Bearing versions and maximum speeds See Chapter "Mechanical properties of the motors" Encoder systems, built-in without DRIVE-CLiQ interface * Absolute encoder EnDat 2048 S/R (AM2048 S/R encoder) * Incremental encoder sin/cos 1 Vpp 2048 S/R with C and D tracks (IC2048 S/R encoder) * Incremental encoder sin/cos 1 Vpp 512 S/R without C and D tracks (encoder IN512 S/R) * Incremental encoder sin/cos 1 Vpp 256 S/R without C and D tracks (encoder IN256 S/R) * Incremental encoder HTL 1024 S/R (encoder HTL1024 S/R) * Incremental encoder HTL 2048 S/R (encoder HTL2048 S/R) 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 29 Motor description 2.3 Technical characteristics and environmental conditions Encoder systems, built-in with DRIVE-CLiQ interface * Absolute encoder, 22-bit singleturn + 12-bit multiturn (encoder AM22DQ) * Incremental encoder, 22-bit, with commutation position (encoder IC22DQ) * Incremental encoder 20-bit without commutation position (encoder IC20DQ) * Incremental encoder 19-bit without commutation position (encoder IC19DQ) Connection Connector for signals or DRIVE-CLiQ interface (mating connector not included in scope of supply) SH 80 to SH 132: Terminal box NDE top / power connector SH 160 to SH 225: Terminal box NDE top SH 280: Terminal box NDE right Nameplate (adhesive label) 1 nameplate adhesively attached to motor 1 nameplate supplied loose in terminal box Paint finish Standard paint finish in anthracite RAL 7016 Options Refer to Options and Selection and Ordering data Approvals, in accordance with cURus 1) Radial eccentricity of the shaft extension, concentricity of centering wheel and axial eccentricity of the mounting flange with respect to the axis of the shaft extension. 2) Applies to the "High Performance" and "Premium Performance" versions SH = Shaft Height S/R = Signal/Revolution DE = Drive End (motor drive end) NDE = Non-Drive End (motor fan end) Table 2- 2 Water cooling Insulation of the stator winding in accordance with EN 60034-1 (IEC 60034-1) For a coolant inlet temperature of up to +30 C SH 80 ... SH 280: Temperature class 180 (H)3) Cooling in accordance with EN 60034-6 (IEC 60034-6) Water cooling max. Cooling water pressure at inlet: 6 bar connection thread at NDE (for further data, see Chapter "Mechanical properties of the motors") Temperature monitoring Temperature sensor in the stator winding SH 180 ... SH 280: Additional temperature sensor as a standby Type in accordance with EN 60034-7 (IEC 60034-7) SH 80: SH 100 ... SH 280: IM B3, IM B5 IM B3, IM B5, IM B35 Degree of protection in accordance with EN 60034-5 (IEC 60034-5) SH 80 ... SH 160: SH 180 ... SH 280 IP65 IP55 Shaft extension at the drive end (DE) in accordance with DIN 748-3 (IEC 60072-1) Plain shaft or feather key, full-key or half-key balancing for feather key Shaft and flange accuracy in accordance with DIN 42955 (IEC 60072-1)1) SH 80 ... SH 160: SH 180 ... SH 280 Tolerance R/A (reduced), SPECIAL2) Tolerance N (normal) 1PH8 main motors 30 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Motor description 2.3 Technical characteristics and environmental conditions Vibration magnitudes in accordance with Siemens / EN 60034-14 (IEC 60034-14) SH 80 ... SH 160: Sound pressure level SH 80 ... SH 132: 68 dB at a rated pulse frequency of 4 kHz and a speed range up to 5000 rpm SH 160: 69 dB at a rated pulse frequency of 4 kHz and a speed range up to 5000 rpm SH 180 and SH 225: 70 dB at a rated pulse frequency of 2 or 4 kHz and speed ranges: in accordance with DIN EN ISO 1680, max. Tolerance +3 dB SH 180 ... SH 280: SH 280: Level R/A, SPECIAL2) Level A * SH 180 up to 5000 rpm * SH 225 up to 4500 rpm 72 dB at a rated pulse frequency of 2 kHz and a speed range up to 3300 rpm (For further data, see Section "Mechanical properties of the motors") Bearing versions and maximum speeds See Chapter "Mechanical properties of the motors" Encoder systems, built-in without DRIVE-CLiQ interface * Absolute encoder EnDat 2048 S/R (AM2048 S/R encoder) * Incremental encoder sin/cos 1 Vpp 2048 S/R with C and D tracks (IC2048 S/R encoder) * Incremental encoder sin/cos 1 Vpp 512 S/R without C and D tracks (encoder IN512 S/R) * Incremental encoder sin/cos 1 Vpp 256 S/R without C and D tracks (encoder IN256 S/R) Encoder systems, built-in with DRIVE-CLiQ interface * Incremental encoder HTL 1024 S/R (encoder HTL1024 S/R) * Incremental encoder HTL 2048 S/R (encoder HTL2048 S/R) * Absolute encoder, 22-bit singleturn + 12-bit multiturn (encoder AM22DQ) * Incremental encoder, 22-bit, with commutation position (encoder IC22DQ) * Incremental encoder 20-bit without commutation position (encoder N20DQ) * Incremental encoder 19-bit without commutation position (encoder N19DQ) Connection Connector for signals or DRIVE-CLiQ interface (mating connector not included in scope of supply) SH 80 ... SH 132: Terminal box NDE top / power connector SH 160 ... SH 280: Terminal box NDE top Nameplate (adhesive label) 1 nameplate adhesively attached to motor 1 nameplate supplied loose in terminal box Paint finish Standard paint finish in anthracite RAL 7016 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 31 Motor description 2.3 Technical characteristics and environmental conditions Options Refer to Options and Selection and Ordering data Approvals, in accordance with cURus 1) Radial eccentricity of the shaft extension, concentricity of centering wheel and axial eccentricity of the mounting flange with respect to the axis of the shaft extension. 2) Applies to the "High Performance" and "Premium Performance" versions 3) The following motors are designed to conform to temperature class 155 (F) because of the design version: 1PH8107-1F2 1PH8138-2 1PH8107-1M2 1PH8164 1PH8166 1PH8168 SH = Shaft Height S/R = Signal/Revolution DE = Drive End (motor drive end) NDE = Non-Drive End (motor fan end) 2.3.3 Classifying environmental conditions according to climate classes You can classify the environmental conditions for stationary use at weather-protected locations according to standard DIN IEC 60721-3-3. The environmental parameters and their limit values are defined in various classes in this standard. You can assign the SIMOTICS M-1PH8 main motors to climate class 3K4 with the exception of the environmental parameter "condensation". Condensation is not permissible. The higher the last number in the climate class 3K, the greater the requirements of the motor. Table 2- 3 Environmental conditions are based on climate class 3K4 Environmental parameter Unit 3K4 class a) Low air temperature C +5 b) High air temperature C + 40 c) Low relative humidity % 5 d) High relative humidity % 95 e) Low absolute humidity g/m3 1 f) High absolute humidity g/m3 29 g) Rate of temperature change1) C/min 0.5 h) Low air pressure kPa 70 i) High air pressure kPa 106 j) Solar radiation3) W/m2 700 k) Thermal radiation - 2) l) Movement of the air m/s 1.0 m) Condensation - Not permissible n) Wind-driven precipitation (rain, snow, hail, etc.) - - 1PH8 main motors 32 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Motor description 2.3 Technical characteristics and environmental conditions Environmental parameter Unit 3K4 class o) Water (other than rain) - 2) p) Formation of ice - - 1) Averaged over a period of 5 min 2) See types of protection 3) In Central Europe, the midday sun stands at 60 to 65 and, in ideal weather conditions, shines with an irradiance of approx. 700 watts/square meter. In winter, the angles are only 13 to 18 and, even at noon, the irradiance is only approx. 247 watts/square meter. You will find additional data on the ambient conditions, such as ambient temperatures or conditions for transport and storage of the motors, in the relevant chapters of this documentation. 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 33 Motor description 2.4 Derating factors 2.4 Derating factors Derating for ambient/coolant temperature Operation: T = -15 C bis +40 C (without restriction) Under conditions other than those specified above (ambient temperature > 40 C or installation altitude > 1000 m above sea level), the permissible torque/power reduction must be considered (see Chapter "Ambient/coolant temperature (Page 63)") Derating for coolant inlet temperature The motors are designed for operation up to a cooling water inlet temperature of +30 C, provided that all of the specified motor data is complied with. If the inlet temperature of the cooling water deviates from this, the continuous torque will change (see Chapter "Cooling water inlet temperature (Page 67)"). Derating factors for power and signal cables The current-carrying capacity of PVC/PUR-insulated copper cables is specified for cable installation types B1, B2, C and E under continuous operating conditions with reference to an ambient air temperature of 40 C. For other ambient temperatures, the corresponding derating factors must be considered (see Chapter "Derating factors for power and signal cables (Page 1297)"). 2.4.1 Reduction of the max. DC-link voltage At installation altitudes of 2000 m above sea level or higher, the voltage stress on the motors must be reduced accordingly based on the table "Factors for reducing the maximum DC-link voltage" (reciprocal values from EN 60664-1 Table A. 2). Table 2- 4 Factors for reducing the maximum DC-link voltage Installation altitude up to [m] above mean sea level Factor 2,000 1 3,000 0.877 4,000 0.775 5,000 0.656 6,000 0.588 7,000 0.513 8,000 0.444 As the DC link voltage is reduced, the converter output voltage also decreases. This reduces the working range in the torque-speed diagram. 1PH8 main motors 34 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Motor description 2.4 Derating factors You will find the torque-speed diagrams in this Chapter "Technical data." Operation in a vacuum is not permissible because of the low dielectric strength and poor heat dissipation. 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 35 Motor description 2.5 Selection and ordering data 2.5 Selection and ordering data The Article No. suffixes specified in the tables below define the logical system for ordering motors in the 1PH8 series and apply to induction and synchronous motors. You will also find the Article No. suffixes in the Catalogs NC 62 and D 21.4. These suffixes correspond to the actual technical selection and ordering data of these catalogs. Supplementary to the information in Catalogs NC 62 and D 21.4, the technical selection and ordering data are integrated in Chapter "Technical data and characteristics" of this Configuration Manual. Depending on the electrical and mechanical configuration, Z options can be appended to the Article No. suffixes. 2.5.1 Article No. suffixes for shaft height 80 to 160 Descriptions Data position in Article No. 1 2 3 4 5 6 Shaft height 80 1 P H 8 0 8 Shaft height 100 1 0 Shaft height 132 1 3 Shaft height 160 1 6 7 - 8 9 10 11 12 - 13 14 15 16 - Z Overall length (cannot be selected, determined by the choice of rated power) Induction version 1 Synchronous version (only shaft height 132 and 160) Encoder systems for Motors without a DRIVE-CLiQ interface 2 Without an encoder 1) A Absolute encoder EnDat 2048 S/R (encoder AM2048S/R) 2) E Incremental encoder HTL 1024 S/R (encoder HTL1024S/R) 1) 3) H Incremental encoder HTL 2048 S/R (encoder HTL2048S/R) 1) 4) J Incremental encoder HTL 1024 S/R (encoder HTL1024S/R) with connection via additional terminal box W Incremental encoder HTL 2048 S/R (encoder HTL2048S/R) with connection via additional terminal box Y Incremental encoder sin/cos 1 Vpp 2048 S/R with C and D tracks (encoder IC2048S/R) 2) M Incremental encoder sin/cos 1 Vpp 512 S/R without C and D tracks (encoder IN512S/R) 1) 5) 10) D Incremental encoder sin/cos 1 Vpp 256 S/R without C and D tracks (encoder IN256S/R)1) 10) C 1) 3) 17) 1) 4) 17) 1PH8 main motors 36 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Motor description 2.5 Selection and ordering data Descriptions Data position in Article No. 1 2 3 4 5 6 7 - 8 9 10 11 12 - 13 14 15 16 - Encoder systems for Absolute encoder 22-bit singleturn + 12-bit multiturn (encoder AM22DQ) 2) F 1 Motors with DRIVE-CLiQ interfaces Incremental encoder 22-bit with commutation position (encoder IC22DQ) 2) D 1 Incremental encoder 20-bit without commutation position (encoder IN20DQ) 1) 5) 10) U 1 Incremental encoder 19-bit without commutation position (encoder IN19DQ) 1) 10) S 1 Winding version Rated speeds (380 V to 480 V 3 AC) Cooling Type of construction 400 rpm, 500 rpm, 600 rpm, 700 rpm B 1000 rpm, 1150 rpm, 1350 rpm, 1500 rpm D 1500 rpm, 1750 rpm, 2000 rpm, 2200 rpm F 2000 rpm, 2300 rpm, 2650 rpm, 2800 rpm G 2500 rpm, 2800 rpm, 3000 rpm L 3000 rpm, 3300 rpm, 3600 rpm, 3900 rpm M 4500 rpm, 5000 rpm, 5500 rpm, 6000 rpm N Star-delta (wye-delta) circuit 1) (380 V to 480 V 3 AC)) 1500/4000 rpm, 2000/5000 rpm, 2500/6000 rpm S Forced ventilation DE -> NDE (degree of protection IP 55) 0 Forced ventilation NDE -> DE (degree of protection IP 55) 1 Water cooling (degree of protection IP 65) 2 IM B3 (IM V5, IM V6, IM B6, IM B7, IM B8) 0 IM B5 (IM V1, IM V3) 2 14) IM B35 (IM V15, IM V35) 6) Z 3 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 37 Motor description 2.5 Selection and ordering data Descriptions Data position in Article No. 1 2 3 4 5 6 7 - 8 9 10 11 12 - 13 14 15 16 - Shaft extension (DE) Balancing Smooth shaft (without keyway) --- 0 Fitted key 11) Full-key 1 Fitted key Half-key 2 Smooth hollow shaft 1) 10) 19) --- 3 Bearings Vibration quality acc. to Siemens/EN 60034-14 11) Z Shaft and flange accuracy Standard with R/A location bearing R B Standard with S/A location bearing R C Standard with SR/A location bearing R D Standard 15) R/A R G Standard 15) S/A R H Increased radial R/A forces 15) 18) R F Performance 7) SPECIAL/B SPECIAL L High Performance 13) SPECIAL/B SPECIAL M Advanced Lifetime 8) 15) S/A R Q Power connection Cable entry Signal connection (looking onto DE) Terminal box (top) right DE A Terminal box (top) left DE B Terminal box (top) NDE left C Terminal box (top) 16) DE left D Power connector (top) 9) 12) right DE E Power connector (top) 9) 12) left DE F Power connector (top) 9) 12) NDE left G 15) 15) 1) 15) 1PH8 main motors 38 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Motor description 2.5 Selection and ordering data Descriptions Data position in Article No. 1 Power connector (top) 9) 12) 2 3 DE 4 5 6 7 - 8 9 10 11 12 - 13 14 15 16 - left Z H Version Without a DRIVE-CLIQ interface, KTY-84 temperature sensor in the stator winding 1 Without a DRIVE-CLIQ interface, PT1000 temperature sensor in the stator winding 2 With a DRIVE-CLiQ interface 1 Special version (order codes are required for options) Z 1) Only possible if the 8th data position is "1" (induction version) 2) Limited to nmax = 12,000 rpm 3) Limited to nmax = 9000 rpm 4) Limited to nmax = 4600 rpm 5) Limited to nmax = 15,000 rpm 6) Only possible for shaft height 100, 132, and 160. 7) Only possible if 8th data position is "1" (induction version) Shaft height 80: limited to nmax = 15,000 rpm Shaft height 100: limited to nmax = 12,000 rpm Shaft height 132: limited to nmax = 10,000 rpm Shaft height 160: limited to nmax = 9000 rpm; not possible if 12th data position is "2" (IM B5) 8) Limited to nmax = 5000 rpm, shaft height 132: nmax = 4500 rpm, shaft height 160: nmax = 4000 rpm 9) Power connector for shaft height 100 only possible up to a maximum stall current of Io = 36 A Power connector for shaft height 132 only possible up to a maximum stall current of Io = 85 A Power connector not possible for shaft height 160 10) Only possible if 14th data position: L, M, and 9th data position is C, S. 11) Not possible if 14th data position: M 12) Not possible for motors in a star-delta (wye-delta) circuit if the 10th data position is "S" 13) Only possible if 8th data position is "1" (induction version) Shaft height 80: limited to nmax = 20,000 rpm Shaft height 100: limited to nmax = 18,000 rpm Shaft height 132: limited to nmax = 15,000 rpm Shaft height 160: limited to nmax = 10,000 rpm; not possible if 12th data position is "2" (IM B5) 14) Not possible with shaft height 160 and 14th data position: L, M 15) Not possible if 9th data position: T, U 16) Not possible with shaft height 160 and 8th data position is "2" or "4" (synchronous version). 17) Only possible if 14th data position: B, C, D, G, H, Q, F; and 15th data position: A and B 18) Limited to SH 100: nmax = 7000 rpm, shaft height 132: nmax = 6500 rpm, shaft height 160: nmax = 5300 rpm 19) Only possible if 9th data position: A, C, and S 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 39 Motor description 2.5 Selection and ordering data 2.5.2 Article No. suffixes for SH 80 Premium Performance Descriptions Data position in Article No. Shaft height 80 1 2 3 4 1 P H 8 5 6 0 8 Overall length 7 - 8 9 10 11 12 - 13 14 15 16 - Z 1 3 7 Induction version Encoder systems 1 Incremental encoder sin/cos 1 Vpp 256 S/R without C and D tracks (encoder N256S/R) C for motors without a DRIVE-CLiQ interface Encoder systems Incremental encoder 19-bit without commutation position S (encoder IN19DQ) 1 For motors with a DRIVE-CLiQ interface Winding version Rated speeds D (380 V to 480 V 3 AC) U V W Cooling Forced ventilation DE -> NDE (degree of protection IP 55) 0 Forced ventilation NDE -> DE (degree of protection IP 55) 1 Water cooling (degree of protection IP 65) 2 1PH8 main motors 40 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Motor description 2.5 Selection and ordering data Descriptions Data position in Article No. 1 2 3 4 5 6 7 - 8 9 10 11 12 - 13 14 15 16 - Z Type of construction IM B5 (IM V1, IM V3) 2 Shaft extension (DE) 1) Balancing Smooth shaft (without keyway) --- 0 Plain hollow shaft 2) --- 3 Bearings Vibration severi- Shaft and ty acc. to flange accuracy Siemens/EN 60034-14 Premium Performance 3) SPECIAL/B SPECIAL Terminal box Cable entry Signal connection top right DE A top left DE B top NDE left C top DE left D Power connector Cable entry Signal connection top right DE E top left DE F top NDE left G top DE left H N (looking onto DE) (looking onto DE) Version Without a DRIVE-CLIQ interface, KTY-84 temperature sensor in the stator winding 1 Without a DRIVE-CLIQ interface, PT1000 temperature sensor in the stator winding 2 With a DRIVE-CLiQ interface 1 Options for SH 80 Premium Performance: Prepared for bearingless rotary unions Y6 4 Sealing air connection Q 12 Flange for design IM B5 with 4 x M8 threaded holes Q 52 1) Shaft extension 24 mm x 50 mm (d x l) 2) Only possible in combination with option Y64. 3) For cooling the greased bearing (to lengthen bearing replacement intervals) and to protect against penetrating liquid, Option Q12 (sealing air connection) is recommended for Premium Performance. 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 41 Motor description 2.5 Selection and ordering data 2.5.3 Article No. suffixes for SH 180 to 280 Descriptions Data position of the order No. 1 2 3 4 1 P H 8 5 6 Shaft height 180 1 8 Shaft height 225 2 2 Shaft height 280 (only induction version and water cooling) 2 8 7 - 8 9 10 11 12 - 13 14 15 16 - Z Overall length (cannot be selected, determined by the choice of rated power) Induction version 1 Synchronous version 2 Encoder systems for motors without a Without an encoder A E DRIVE-CLiQ interface Absolute encoder EnDat 2048 S/R (encoder AM2048S/R) Incremental encoder HTL 1024 S/R (encoder HTL1024S/R) 1) H Incremental encoder HTL 2048 S/R (encoder HTL2048S/R) 1) 4) J 1) Incremental encoder HTL 1024 S/R (encoder W HTL1024S/R) with connection via additional terminal box 1) Incremental encoder HTL 2048 S/R (encoder Y HTL2048S/R) with connection via additional terminal box 1) 4) Encoder systems for motors with a DRIVE-CLiQ interface Incremental encoder sin/cos 1 Vpp, 2048 S/R with C and D track (encoder IC2048S/R) M Absolute encoder, 22-bit singleturn + 12-bit multiturn (encoder AM22DQ) F 1 Incremental encoder, 22-bit, with commutation position (encoder IC22DQ) D 1 Winding version Rated speeds 400 rpm, 500 rpm, 600 rpm, 700 rpm B 700 rpm, 800 rpm, 1000 rpm, 1100 rpm C 1000 rpm, 1150 rpm, 1350 rpm, 1500 rpm D 1500 rpm, 1750 rpm, 2000 rpm, 2200 rpm F 2500 rpm, 2900 rpm, 3200 (3400) rpm L Rated speeds 400 rpm, 500 rpm H (690 V 3 AC) 700 rpm, 800 rpm K for shaft height 280 1000 rpm, 1150 rpm U 1500 rpm, 1750 rpm W (380 V to 480 V 3 AC) 1PH8 main motors 42 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Motor description 2.5 Selection and ordering data Descriptions Data position of the order No. 1 Cooling 2 3 Forced ventilation, DE-->NDE 4 5 6 7 - 8 9 10 11 12 - 13 14 15 16 - Z (degree of protection IP 55) 0 Forced ventilation, NDE-->DE (degree of protection IP 55) 1 Water cooling (degree of protection IP 55) 2 Open-circuit ventilation, DE->NDE (for induction version only) (degree of protection IP 23) 3 Open-circuit ventilation, NDE->DE (induction version only) Type of construction Shaft height 180 Shaft height 225 IM B3 (IM B6, IM B7, IM B8, IM V6) IM V5 4 Shaft height 280 IM B3 (IM V6) 0 M V5 9) 1 IM B5 with A660 flange 2 IM B5 with A450 flange IM B5 with A550 flange (IM V3) 5) (IM V3) 6) IM B35 with A450 flange IM B35 with A550 flange IM B35 with A660 flange (IM V35) (IM V35) (IM V35) IM V15 with A450 flange IM V15 with A550 flange IM V15 with flange A660 9) (IM V3) 7) 9) 3 5 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 43 Motor description 2.5 Selection and ordering data Descriptions Data position of the order No. 1 2 3 4 5 6 7 - 8 9 10 11 12 - 13 14 15 16 - Z Shaft extension (DE) Balancing Smooth shaft (without keyway) --- 0 Fitted key Full-key 1 Fitted key Half-key 2 Bearings Vibration severity acc. to Siemens/ EN 60034-14 Shaft and flange accuracy Standard A N A Standard R/A R B Increased radial A forces N E Increased radial R/A forces R F also possible with shaft heights 180 and 225: Standard S/A R C SR/A R D SR/A R L Power connection Cable entry Signal connection Terminal box (top) right DE A Terminal box (top) left DE B Terminal box (top) NDE right C Terminal box (top) DE right D Standard 1) Performance 1) 8) (looking onto DE) Version Without a DRIVE-CLIQ interface, KTY-84 temperature sensor in the stator winding 1 Without a DRIVE-CLIQ interface, PT1000 temperature sensor in the stator winding 2 With a DRIVE-CLiQ interface 1 Special version (order codes are required for options) Z 1PH8 main motors 44 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Motor description 2.5 Selection and ordering data Descriptions Data position of the order No. 1 2 3 4 5 6 7 - 8 9 10 11 12 - 13 14 15 16 - Z 1) Only possible if the 8th data position is "1" (induction version) 4) Limited to nmax = 4600 rpm 5) Limited to nmax = 3000 rpm, not possible if 14th data position is "L" (Performance) 6) Limited to nmax = 2500 rpm, not possible if 14th data position is "L" (Performance) 7) Limited to nmax = 2000 rpm 8) Only possible with shaft height 180: Limited to nmax = 7500 rpm, not possible if 12th data position is "2" (IM B5) and 11th data position is "3" and "4" (open-circuit ventilation) only possible for shaft height 225: limited to nmax = 6000 rpm, not possible if 12th data position is "2" (IM B5) and 11th data position is "3" and "4" (open-circuit ventilation) 9) Only possible if 14th data position is "A" or "B" (standard bearing) 2.5.4 Article No. suffixes for SH 280 Descriptions Data position of the order No. 1 2 3 4 1 P H 8 Shaft height 280 (forced ventilation and open-circuit ventilation) 5 6 2 8 7 - 8 9 10 11 12 - 13 14 15 16 - Z Overall length (cannot be selected, determined by the choice of rated power) Induction version Encoder systems 1 Without an encoder A Absolute encoder EnDat 2048 S/R (encoder AM2048S/R) E Incremental encoder HTL 1024 S/R (encoder HTL1024S/R) H Incremental encoder HTL 2048 S/R (encoder HTL2048S/R) J Incremental encoder HTL 1024 S/R (encoder HTL1024S/R) with connection via additional terminal box W Incremental encoder HTL 2048 S/R (encoder HTL2048S/R) with connection via additional terminal box Y Incremental encoder sin/cos 1 Vpp, 2048 S/R with C and D track (encoder IC2048S/R) M Encoder systems Absolute encoder, 22-bit singleturn + 12-bit multiturn (encoder AM22DQ) F 1 for motors with a Incremental encoder, 22-bit, with commutation position (encoder IC22DQ) D 1 for motors without a DRIVE-CLiQ interface 7) 7) DRIVE-CLiQ interface 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 45 Motor description 2.5 Selection and ordering data Descriptions Data position of the order No. 1 External encoder systems 4 5 6 7 - 8 9 G Incremental encoder HTL 1024 S/R POG 10 (BaumerHubner), prepared for mounting 2) K (380 V to 480 V 3 AC) Type of construction 3 Incremental encoder HTL 1024 S/R POG 22 (BaumerHubner), prepared for mounting 1) Winding version Rated speeds Cooling 2 10 11 12 - 13 14 15 16 - Z 400 rpm, 500 rpm, 600 rpm, 700 rpm B 700 rpm, 800 rpm, 1000 rpm, 1100 rpm C 1000 rpm, 1150 rpm, 1350 rpm, 1500 rpm D 1500 rpm, 1750 rpm, 2000 rpm, 2200 rpm F Rated speeds 400 rpm, 500 rpm H (690 V 3 AC) 700 rpm, 800 rpm K 1000 rpm, 1150 rpm U 1500 rpm, 1750 rpm W Forced ventila- (degree of protection IP 55) tion 1 Forced ventila- (open-circuit ventilation with degree of protection tion IP 23) 4 IM B3 (IM V6) IM V5 0 1 6) IM B5 with A660 flange (IM V3) 6) 2 IM B35 with A660 flange (IM V35) 3 IM V15 with flange A660 5 6) Shaft extension (DE) Balancing Smooth shaft (without keyway) --- 0 Fitted key Full-key 1 Fitted key Half-key 2 Bearings Vibration severi- Shaft and ty acc. to flange accuracy Siemens/EN 60034-14 Standard A N A Standard R/A R B Increased radial A forces N E Increased radial R/A forces R F 1PH8 main motors 46 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Motor description 2.5 Selection and ordering data Descriptions Data position of the order No. 1 2 3 4 Power connection Cable entry Signal connection Terminal box NDE right bottom DE Terminal box NDE left Terminal box NDE top Terminal box DE top 4) bottom right right 5 6 7 - 8 9 10 11 12 - 13 14 15 16 - Z External fan U NDE top, air inlet from NDE, air-flow direction NDE-->DE --- NDE left, air inlet from NDE, air-flow direction NDE-->DE G 00 DE V NDE top, air inlet from NDE, air-flow direction NDE-->DE --- NDE right, air inlet from NDE, air-flow direction NDE-->DE G 02 DE W NDE left, air inlet from NDE, air-flow direction NDE-->DE G 00 NDE right, air inlet from NDE, air-flow direction NDE-->DE G 02 X NDE NDE top, air inlet from NDE, air-flow direction NDE-->DE 4) 5) --- NDE left, air inlet from NDE, air-flow direction NDE-->DE G 00 4) NDE right, air inlet from NDE, air-flow direction NDE-->DE 4) G 02 Version Without a DRIVE-CLIQ interface, KTY-84 temperature sensor in the stator winding 1 Without a DRIVE-CLIQ interface, PT1000 temperature sensor in the stator winding 2 With a DRIVE-CLiQ interface 1 For other versions, see options Z 1) When ordering, also select option H75 2) When ordering, also select options H56 or G80 4) Only possible if 12th data position is "0" (IM B3) and "1" (IM V5). 5) Only possible for assignments with terminal box 1XB7712-P. 6) Only possible if 14th data position is "A" and "B" (standard bearing); nmax limited to 2000 rpm 7) Only possible for the following combinations: 12th data position is "0" or "1" if 15th data position is "W" or "X" 12th data position is "2," "3," or "5" if 15th data position "W" 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 47 Motor description 2.5 Selection and ordering data 2.5.5 Article No. suffix for SH80 to 160 + holding brake DE Descriptions Data position of the order No. 1 2 3 4 1 P H 8 5 6 Shaft height 80 0 8 Shaft height 100 1 0 Shaft height 132 1 3 Shaft height 160 1 6 7 - 8 9 10 11 12 - 13 14 15 16 - Z Overall length (cannot be selected, determined by the choice of rated power) Induction version with holding brake 1) 3 Synchronous version with holding brake (only shaft heights 132 and 160) 1) 4 Encoder systems for motors without a DRIVE-CLiQ interface without encoder 2) A Absolute encoder EnDat 2048 S/R (encoder AM2048S/R) E Incremental encoder HTL 1024 S/R (encoder HTL1024S/R) 2) H Incremental encoder HTL 2048 S/R (encoder HTL2048S/R) 2) J Incremental encoder HTL 1024 S/R (encoder W HTL1024S/R) with connection via additional terminal box 2) 9) Incremental encoder HTL 2048 S/R (encoder Y HTL2048S/R) with connection via additional terminal box 2) 9) Incremental encoder sin/cos 1 Vpp, 2048 S/R with C and D track (encoder IC2048S/R) M Encoder systems Absolute encoder, 22-bit singleturn + 12-bit multiturn (encoder AM22DQ) F 1 for motors with a Incremental encoder, 22-bit, with commutation position (encoder IC22DQ) D 1 DRIVE-CLiQ interface Winding version Cooling Type of construction Forced ventilation DE -> NDE (degree of protection IP 55) 0 Forced ventilation NDE -> DE (degree of protection IP 55) 1 Water cooling (degree of protection IP 55) 4) 2 IM B5 (IM V1, IM V3) 5) 2 IM B35 (IM V15, IM V35) 8) 3 1PH8 main motors 48 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Motor description 2.5 Selection and ordering data Descriptions Data position of the order No. 1 2 3 4 5 6 7 - 8 9 10 11 12 - 13 14 15 16 - Z Shaft extension (DE) Balancing Smooth shaft (without keyway) --- 0 Fitted key Half-key 2 Bearings Vibration severi- Shaft and ty acc. to flange accuracy Siemens/EN 60034-14 Standard A N A Advanced Lifetime A N P Power connection 6) Cable entry Signal connection Terminal box (top) right DE A Terminal box (top) left DE B Terminal box (top) NDE left C Terminal box (top) 10) DE left D Power connector (top) 3) 7) right DE E Power connector (top) 3) 7) left DE F Power connector (top) 3) 7) NDE left G Power connector (top) 3) 7) DE left H (looking onto DE) Version Without a DRIVE-CLIQ interface, KTY-84 temperature sensor in the stator winding 1 Without a DRIVE-CLIQ interface, PT1000 temperature sensor in the stator winding 2 With a DRIVE-CLiQ interface 1 Brake versions: Brake supply voltage 230 V 1 AC, 50/60 Hz Holding brake DE U6 0 Holding brake DE with microswitch U6 1 Holding brake DE with manual brake release lever U6 2 Holding brake DE with microswitch and manual brake release lever U6 3 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 49 Motor description 2.5 Selection and ordering data Descriptions Data position of the order No. 1 Brake supply voltage 24 V DC 2 3 4 5 6 7 - 8 9 10 11 12 - 13 14 15 16 - Z Holding brake DE U6 5 Holding brake DE with microswitch U6 6 Holding brake DE with manual brake release lever U6 7 Holding brake DE with microswitch and manual brake release lever U6 8 Z options that cannot be combined with holding brake DE: K18, V91, M03, M39 1) A U option must also be stated in the order to specify the holding brake version. Shaft height 80: limited to nmax = 5000 rpm Shaft height 100: limited to nmax = 5000 rpm Shaft height 132: limited to nmax = 4500 rpm Shaft height 160: limited to nmax = 4000 rpm 2) Only possible if 8th data position is "3" (induction version) 4) With holding brake, degree of protection is limited to IP55. 5) Not possible with shaft height 160. 6) Connection for holding brake is only possible via terminal box (top). 7) Power connector for motor only (not with holding brake): Power connector for shaft height 100 only possible up to a maximum stall current of Io = 36 A. Power connector for shaft height 132 only possible up to a maximum stall current of Io = 85 A. Power connector not possible for shaft height 160 8) Not possible for shaft height 80 9) Only possible if 15th data position: A and B 10) Not possible with shaft height 160 and 8th data position is "4" (synchronous version) 2.5.6 Article No. suffix for SH180 to 225 + holding brake Descriptions Data position of the order No. 1 2 3 4 5 6 Shaft height 180 1 P H 8 1 8 Shaft height 225 2 2 7 - 8 9 10 11 12 - 13 14 15 16 - Z Overall length Induction version with holding brake 1) Synchronous version with holding brake Encoder systems for motors with- 3 1) 4 without encoder 2) A Absolute encoder EnDat 2048 S/R (encoder AM2048S/R) E 1PH8 main motors 50 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Motor description 2.5 Selection and ordering data Descriptions out a Data position of the order No. 1 2 3 4 5 6 7 - 8 9 10 11 12 - 13 14 15 16 - Z Incremental encoder HTL 1024 S/R (encoder HTL1024S/R) 2) H Incremental encoder HTL 2048 S/R (encoder HTL2048S/R) 2) J Incremental encoder HTL 1024 S/R (encoder HTL1024S/R) with connection via additional terminal box W Incremental encoder HTL 2048 S/R (encoder HTL2048S/R) with connection via additional terminal box Y Incremental encoder sin/cos 1 Vpp, 2048 S/R with C and D track (encoder IC2048S/R) M Encoder systems Absolute encoder, 22-bit singleturn + 12-bit multiturn (encoder AM22DQ) F 1 for motors with a Incremental encoder, 22-bit, with commutation position (encoder IC22DQ) D 1 DRIVE-CLiQ interface 2) 2) DRIVE-CLiQ interface Winding version Cooling Forced ventilation, DE-->NDE (degree of protection IP 55) 0 Forced ventilation, NDE-->DE (degree of protection IP 55) 1 Water cooling (degree of protection IP 55) 2 Open-circuit ventilation, NDE-->DE (induction version only) (degree of protection IP 23) 4 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 51 Motor description 2.5 Selection and ordering data Descriptions Data position of the order No. 1 2 3 4 5 6 7 - 8 9 10 11 12 - 13 14 15 16 - Z Type of construction IM B3 (IM B6, IM B7, IM B8) 0 Shaft extension (DE) Balancing Fitted key Half-key Bearings Vibration severi- Shaft and ty acc. to flange accuracy Siemens/EN 60034-14 Standard A N Power connection 3) Cable entry Signal connection Terminal box (top) right DE A Terminal box (top) left DE B Terminal box (top) NDE right C Terminal box (top) DE right D 2 A (looking onto DE) Version Without a DRIVE-CLIQ interface, KTY-84 temperature sensor in the stator winding 1 Without a DRIVE-CLIQ interface, PT1000 temperature sensor in the stator winding 2 With a DRIVE-CLiQ interface 1 Brake versions: Brake supply voltage Holding brake DE with microswitch and manual brake release lever 230 V 1 AC, 50/60 Hz U6 3 Z options that cannot be combined with holding brake DE: K18, K90, L03, V92, M39 1) A U option must also be stated in the order to specify the holding brake version. Shaft height 180: limited to nmax = 3500 rpm Shaft height 225: limited to nmax = 3100 rpm 2) Only possible if 8th data position is "3" (induction version) 3) Connection for holding brake is only possible via brake terminal box (top). 1PH8 main motors 52 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Motor description 2.5 Selection and ordering data 2.5.7 Options Order code Option description For use with motors "" = Option possible, "---" = Option not possible When ordering a motor with options, "-Z" should be added to the order number. The order code must also be specified for each additional required option (order codes must not be repeated in plain text in the order) Shaft height Shaft height 80 to 160 180 to 280 Shaft height 280 for forced ventilation only (11th data position is "1" or "4") A12 Additional chain of PTC thermistors for alarm and trip (only possible for version with terminal box) A25 Additional temperature sensor as reserve connected to signal terminal strip (only possible for version with terminal box) Standard Standard A72 2 PT100 resistance thermometers for bearing temperature monitoring (DE and NDE) --- B02 Factory test certificate in accordance with EN 10204 2.3 (for motor ordered) Standard Standard B35 Factory test certificate for vibration log 5) 5) B36 Factory test certificate for run-out log only for SH 180 and SH 225 --- G00 External fan NDE left, air inlet at NDE (possible if 15th data position is U, W, or X) --- --- G02 External fan NDE right, air inlet at NDE (possible if 15th data position is V, W, or X) --- --- G06 External fan DE left, air inlet NDE (possible if 11th position =1 and 15th position = U, V, or W; possible if 11th position =4 and 15th position = W) --- --- G07 External fan DE left, air inlet DE (possible if 11th position =1 and 15th position = U, V, or W; possible if 11th position =4 and 15th position = W) --- --- G08 External fan DE right, air inlet NDE (possible if 11th position =1 and 15th position = U, V, or W; possible if 11th position =4 and 15th position = W) --- --- G09 External fan DE right, air inlet DE (possible if 11th position =1 and 15th position = U, V, or W; possible if 11th position =4 and 15th position = W) --- --- G11 External fan DE top, air inlet DE (possible if 11th position =1 and 15th position = U, V, or W; possible if 11th position =4 and 15th position = W) --- --- G14 With external fan (only possible if 11th data position is "1" or "4") only for SH 132 and SH 160 G50 Nipple for SPM, with M8 adapter --- 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 53 Motor description 2.5 Selection and ordering data Order code Option description For use with motors "" = Option possible, "---" = Option not possible When ordering a motor with options, "-Z" should be added to the order number. The order code must also be specified for each additional required option (order codes must not be repeated in plain text in the order) Shaft height Shaft height 80 to 160 180 to 280 Shaft height 280 for forced ventilation only (11th data position is "1" or "4") G80 Mounting of a POG 10 incremental encoder supplied by customer (possible if 9th data position is "K") --- --- H56 Mounting of an incremental encoder POG 10 D 1024 (encoder HTL1024 S/R) (possible if 9th data position is "K") --- --- H75 Mounting of a hollow-shaft encoder HOG 22 supplied by customer (possible if 9th data position is "G") --- --- K08 Encoder connection or DRIVE-CLiQ mounted on the opposite side (not possible if 15th data position is "X") --- K09 Terminal box or power connector NDE right only for SH 100 1) to SH 160 --- --- --- --- only for SH 100 1) to SH 160 --- --- Terminal box NDE left, cable entry DE, signal connection top (possible if 15th data position is "A") --- --- K16 Second shaft extension (d x l: 95 mm x 170 mm) (possible if 9th data position is "A" or "G" and 12th data position is "0" or "3") --- --- K17 Labyrinth seal DE for Performance version (14th data position "L") --- K18 Radial shaft sealing ring DE 2) K40 Regreasing system, DE and NDE --- K45 Anti-condensation heating 230 V AC --- K69 Pipe connection prepared NDE right (only possible with forced ventilation, not for G00 to G11) --- --- K70 Pipe connection prepared NDE left (only possible with forced ventilation, not for G00 to G11) --- --- K71 Pipe connection prepared NDE top (only possible with forced ventilation, not for G00 to G11) --- --- K80 Axial pipe connection NDE (only possible with forced ventilation) only for SH 180 and SH 225 Options K69, K70, K71 Terminal box NDE right, cable entry DE, signal connection top (possible if 15th data position is "A") K10 Terminal box or power connector NDE left Only for SH 180 only for SH 180 and SH 225 ----Standard 1PH8 main motors 54 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Motor description 2.5 Selection and ordering data Order code Option description For use with motors "" = Option possible, "---" = Option not possible When ordering a motor with options, "-Z" should be added to the order number. The order code must also be specified for each additional required option (order codes must not be repeated in plain text in the order) Shaft height Shaft height 80 to 160 180 to 280 K83 Terminal box rotated through +90 degrees (possible in conjunction with options K09 or K10 or if 15th data position is "U", "V" or "W") --- 4) K84 Terminal box rotated through -90 degrees (possible in conjunction with options K09 or K10 or if 15th data position is "U", "V", "W" or "X") --- 4) K85 Terminal box rotated through +180 degrees (possible in conjunction with options K09 or K10 or if 15th data position is "U", "V", "W" or "X") --- K90 Version with flange size A400 (possible if 12th data position is "2", "3" or "5") --- Only for SH 180 --- L00 Replace terminal box (standard) with the next largest terminal box (note dimension implications in CAD Creator.) --- L02 Screws locked with Loctite and reinforced fan version --- --- L03 Increased resistance to vibration --- only for SH 180 and SH 225 --- L12 Condensation drain hole --- Standard for water cooling Only if 11th data position is "1" L27 NDE bearing in insulated version --- Only for SH 180 Standard L37 Increased maximum speed (SH 80: 12,000 rpm, SH 100: 10,000 rpm) only for SH 80 --- --- L29 Enhanced corrosion protection for installation in industrial/marine climates --- --- L72 Shaft made of special steel (note: option results in longer delivery times) --- --- L74 Fan version in IP65 degree of protection 3) --- --- L75 Special fan version for 400 V 3 AC with degree of protection IP65 3) --- only for SH 180 and SH 225 --- 6) Shaft height 280 for forced ventilation only (11th data position is "1" or "4") and SH 100 (Note: Filter must be ordered with option Q14) M03 Version for potentially explosive atmospheres Zone 2 --- --- M39 Version for potentially explosive atmospheres Zone 22 only for SH 180 and SH 225 --- 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 55 Motor description 2.5 Selection and ordering data Order code Option description For use with motors "" = Option possible, "---" = Option not possible When ordering a motor with options, "-Z" should be added to the order number. The order code must also be specified for each additional required option (order codes must not be repeated in plain text in the order) Shaft height Shaft height 80 to 160 180 to 280 Shaft height 280 for forced ventilation only (11th data position is "1" or "4") M83 Additional back-off thread on motor feet (only possible if 12th data position is "0" or "3") --- --- P00 Undrilled cable entry plate --- not for 1XB7820P00 P01 Cable entry plate 3 x M63 x 1.5 --- only for 1XB7700P02 1XB7712P03 only for 1XB7712P03 P02 Cable entry plate 3 x M75 x 1.5 --- only for 1XB7712P03 only for 1XB7712P01 1XB7712P03 P03 Cable entry plate 4 x M75 x 1.5 --- --- only for 1XB7712P01 P04 Cable entry plate 4 x M63 x 1.5 --- only for 1XB7712P03 only for 1XB7712P01 1XB7712P03 Q00 Extra grounding terminals in terminal box --- --- Q12 Sealing air connection --- --- Q14 Filter for special fan (option L075) (only possible when 11th data position is "1" or "4") --- only for SH 180 and SH 225 --- Q21 Screw locked with Loctite --- --- Q31 Metal nameplate instead of adhesive label Q52 Flange for design IM B5 with 4 x M8 threaded holes (only possible when 14th data position is "N") Q81 Increased bearing preloading (only possible when 14th data position "B", "C" and "D") U60 U61 U62 --- --- --- --- Holding brake 230 V --- --- Holding brake 230 V with microswitch --- --- Holding brake 230 V with manual brake release lever --- --- Only for SH 80 1PH8 main motors 56 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Motor description 2.5 Selection and ordering data Order code Option description For use with motors "" = Option possible, "---" = Option not possible When ordering a motor with options, "-Z" should be added to the order number. The order code must also be specified for each additional required option (order codes must not be repeated in plain text in the order) Shaft height Shaft height 80 to 160 180 to 280 for forced ventilation only (11th data position is "1" or "4") U63 Holding brake 230 V with microswitch and manual brake release lever U65 Holding brake 24 V DC --- --- U66 Holding brake 24 V DC with microswitch --- --- U67 Holding brake 24 V DC with manual brake release lever --- --- U68 Holding brake 24 V DC with microswitch and manual brake release lever --- --- V90 1PH7-compatible shaft extension (d x l: 42 mm (1.65 in) x 110 Only for SH mm (4.33 in) 132 (Note reduced radial forces; only possible if 8th data position is "1" or "3") --- --- V91 1FT6-compatible shaft extension (d x l: 48 mm x 82 mm) (only possible if 8th data position is "2") --- --- V92 1PH7184-/1PL6184-compatible shaft extension (d x l: 60 mm x 140 mm) (only possible if 8th data position is "1") --- only with1PH8184 --- Y64 Hollow shaft prepared for bearingless rotating unions with flange diameter 114H6 --- --- Y82 Extra nameplate with customer specifications (plain text required) --- Y84 Customer specifications on nameplate (max. 30 characters) --- Paint finish anthracite RAL 7016 Only for SH 132 Standard only for SH 180 and SH 225 Shaft height 280 Standard --- Standard X01 Paint finish in RAL 9005 (jet black) X02 Paint finish in RAL 9001 (cream white) X03 Paint finish in RAL 6011 (reseda green) X04 Paint finish in RAL 7032 (pebble gray) X05 Paint finish in RAL 5015 (sky blue) X06 Paint finish in RAL 1015 (light ivory) X08 Paint finish in RAL 9006 (white aluminum) X11 Paint finish in RAL 6019 (pastel green) X12 Paint finish in RAL 5010 (gentian blue) X13 Paint finish in RAL 5024 (pastel blue) X14 Paint finish in RAL 5017 (traffic blue) X15 Paint finish in RAL 9010 (pure white) X16 Paint finish in RAL 6018 (yellow green) 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 57 Motor description 2.5 Selection and ordering data Order code Option description For use with motors "" = Option possible, "---" = Option not possible When ordering a motor with options, "-Z" should be added to the order number. The order code must also be specified for each additional required option (order codes must not be repeated in plain text in the order) Shaft height Shaft height 80 to 160 180 to 280 Paint finish in RAL 5014 (pigeon blue) X18 Paint finish in RAL 9018 (papyrus white) X19 Paint finish in RAL 2004 (pure orange) X20 Paint finish in HWS (gray) X21 Paint finish in RAL 9003 (signal white) X22 Paint finish in RAL 9002 (gray white) X23 Paint finish in RAL 5005 (signal blue) X24 Paint finish in RAL 7001 (sliver gray) X25 Paint finish in RAL 1000 (green beige) X26 Paint finish in RAL 6017 (May green) X27 Paint finish in RAL 9023 (pearl dark gray) X28 Paint finish in RAL 5009 (azure blue) X29 Paint finish in RAL 7005 (mouse gray) X30 Paint finish in RAL 1014 (ivory) X31 Paint finish in RAL 5007 (brilliant blue) X44 Paint finish in RAL 1023 (traffic yellow) X50 Paint finish in RAL 3004 (purple red) X51 Paint finish in RAL 2003 (pastel orange) X52 Paint finish in RAL 3000 (flame red) X53 Paint finish in RAL 7035 (light gray) X54 Paint finish in RAL 7004 (signal gray) X55 Paint finish in RAL 7038 (agate gray) X56 Paint finish in RAL 1013 (oyster white) X57 Paint finish in RAL 5012 (light blue) X58 Paint finish in RAL 2001 (red orange) X59 Paint finish in RAL 7030 (stone gray) X91 Paint finish in RAL 7011 (iron gray) K24 Primer pale green light gray light gray K23 Special paint finish "Worldwide" (anthracite RAL 7016) X17 Shaft height 280 for forced ventilation only (11th data position is "1" or "4") 1PH8 main motors 58 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Motor description 2.5 Selection and ordering data Order code Option description For use with motors "" = Option possible, "---" = Option not possible When ordering a motor with options, "-Z" should be added to the order number. The order code must also be specified for each additional required option (order codes must not be repeated in plain text in the order) Shaft height Shaft height 80 to 160 180 to 280 K23 + X.. Special finish "Worldwide" in another color (X01 to X91) Shaft height 280 for forced ventilation only (11th data position is "1" or "4") 1) Not possible if 12th data position is "2" (type of construction IM B5) 2) Only recommended if oil spray/mist occasionally gets onto the sealing ring. Radial shaft sealing ring not possible if: 14th data position "E", "F" and "L", "M" 3) Regardless of the degree of protection, at high levels of atmospheric pollution, the fan must be cleaned. 4) Not possible for 1PH822 and terminal box 1XB7712-P03 5) Not possible if 14th data position "E" and "F" 6) Only possible if 9th data position "E", "M", "F" and "D" and 14th data position "D" 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 59 Motor description 2.6 Nameplate data (rating plate) 2.6 Nameplate data (rating plate) The nameplate (rating plate) shows the technical specifications for the supplied motor. *) Some fields may also be empty (options, customer data) Figure 2-1 Nameplate layout for 1PH808 to 1PH816 Table 2- 5 Elements on the rating plate No. Description No. Description L010 Article No. L210 Rated power PN (3) L012 Consecutive number L220 cos (3) L020 Factory serial number L230 Rated frequency fN (3) L025 UL mark L240 Rated speed nN (3) L030 Type of construction L250 Operating mode (3) L040 Degree of protection L257 Rated voltage UN (4) L042 Temperature class L258 Connection method (4) L045 Balancing code L260 Rated current IN (4) L048 Operating mode L261 Rated power PN (4) L049 for synchronous motors: induced voltage at rated speed VIN L263 cos (4) for induction motors: cos L265 Rated frequency fN (4) Rated voltage UN (1) L266 Rated speed nN (4) L050 1PH8 main motors 60 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Motor description 2.6 Nameplate data (rating plate) No. Description No. Description L051 Connection method (1) L267 Operating mode (4) L060 Rated current IN (1) L270 Maximum current Imax L070 Rated power PN (1) L275 Maximum torque Mmax L080 cos (1) L280 Maximum speed nmax L090 Rated frequency fN (1) L285 Temperature sensor L100 Rated speed nN (1) L290 Tachometer/resolver L110 Operating mode (1) L295 Cooling method L120 Rated voltage UN (2) L296 Throughput l/min (m3/s) L121 Connection method (2) L297 System pressure L130 Rated current IN (2) L298 Maximum coolant temperature L140 Rated power PN (2) L315 Options (I) L150 cos (2) L320 Options (II) L160 Rated frequency fN (2) L325 Optional customer information L170 Rated speed nN (2) L330 Anti-condensation heating L180 Operating mode (2) L335 Weight L190 Rated voltage UN (3) L191 Connection method (3) L200 Rated current IN (3) The rating plate (type plate) shows the technical specifications for the supplied motor. Figure 2-2 Nameplate layout for 1PH818 to 1PH828 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 61 Motor description 2.6 Nameplate data (rating plate) Table 2- 6 Elements on the rating plate No. Description No. Description 010 Article No. 200 Rated current IN (3) 012 Consecutive number, part of serial number 210 Rated power PN (3) 020 Serial number 220 cos (3) 025 UL mark 230 Rated frequency fN (3) 026 (blank) 240 Rated speed nN (3) 030 Type of construction 250 Operating mode (3) 035 (blank) 255 Code for operating point 3 036 (blank) 260 Rated voltage UN (4) 040 Degree of protection 261 Switching mode 4 045 Type of balancing 270 Rated current IN (4) 050 Rated voltage UN (1) 280 Rated power PN (4) 051 Switching mode 1 290 cos (4) 060 Rated current IN (1) 300 Rated frequency fN (4) 070 Rated power PN (1) 310 Rated speed nN (4) 080 cos (1) 320 Operating mode (4) 090 Rated frequency fN (1) 325 Code for operating point 4 100 Rated speed nN (1) 330 Maximum current IMAX 110 Operating mode (1) 335 Weight 115 Code for operating point 1 340 Maximum torque MMAX 120 Rated voltage UN (2) 350 Maximum speed nMAX 121 Switching mode 2 360 Temperature sensor 130 Rated current IN (2) 370 Tachometer/resolver 140 Rated power PN (2) 380 Cooling method 150 cos (2) 390 Throughput l/min (m3/s) 160 Rated frequency fN (2) 400 System pressure 170 Rated speed nN (2) 410 Maximum coolant temperature 180 Operating mode (2) 420 Options (I) 185 Code for operating point 2 430 Options (II) 190 Rated voltage UN (3) 440 Optional customer information 191 Switching mode 3 450 Anti-condensation heating / dummy 1PH8 main motors 62 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 3 Mechanical properties 3.1 Cooling 3.1.1 General The following table shows an overview of the available variants of cooling system. Table 3- 1 Cooling system variants of 1PH8 motors Shaft height 3.1.2 Forced ventilation Water cooling 80 Motor type Asynchronous 100 Asynchronous 132 Asynchronous and synchronous 160 Asynchronous and synchronous 180 Asynchronous and synchronous 225 Asynchronous and synchronous 280 Asynchronous Forced ventilation When mounting the forced ventilated motor, make sure the motor is well ventilated. Good ventilation is especially important for encapsulated installation. Avoid warm exhaust air being drawn in again. The cooling air must flow in and out without restriction. Avoid accumulated dirt in the cooling ducts as this can reduce the cooling air flow. All catalog data refer to an ambient temperature of 40 C and an installation altitude up to 1000 m above sea level. NOTICE Thermal damage to temperature-sensitive parts The motors can have surface temperatures of over +100 C. Temperature-sensitive parts in contact with the motor or attached to the motor can be damaged. Temperature-sensitive parts include cables and electronic components, for example. * Never attach temperature-sensitive parts to the motor. * Ensure that no temperature-sensitive parts are in contact with the motor. 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 63 Mechanical properties 3.1 Cooling Ambient/coolant temperature Operation: T = -15 C bis +40 C (without restriction) Under conditions other than those specified above (ambient temperature > 40 C 40 C or installation altitude > 1000 m above sea level), the permissible torque/power reduction must be determined from the following table. Ambient temperatures and installation altitudes are rounded off to 5 C or 500 m respectively. Table 3- 2 Factors for reducing the torque/power acc. to EN 60034-6 Installation altitude above sea level Ambient temperature in C 40 45 50 551) 1,000 1.00 0.96 0.92 0.87 1,500 0.97 0.93 0.89 0.84 2,000 0.94 0.90 0.86 0.82 2,500 0.90 0.86 0.83 0.78 3,000 0.86 0.82 0.79 0.75 3,500 0.82 0.79 0.75 0.71 4,000 0.77 0.74 0.71 0.67 1) Only permitted for the "NDE" "DE" direction of air flow Note Higher ambient temperatures For ambient temperatures > 55 C, contact your local Siemens office. The standard motors are not suitable for use in corrosive atmospheres, atmospheres with a high salt content, or in outdoor applications. Mounting a fan and minimum clearance to parts and components mounted by the customer Table 3- 3 Fan mounting Shaft height [mm] Fan mounting 80 to 225 NDE axial, can be rotated through 180 280 NDE radial, different mounting types can be ordered 1PH8 main motors 64 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Mechanical properties 3.1 Cooling Table 3- 4 Minimum distance S between the air intake/outlet openings and other adjacent components Shaft height Minimum clearance S [mm] [mm] 80 30 100 30 132 60 160 80 180/225 100 280 120 Ventilation data and sound pressure levels Table 3- 5 Shaft height Ventilation data and sound pressure levels Air flow direction Degree of protection Air discharge Sound pressure level LpA (1 m) Pressure Motor + operation on an external drop (p) fan 50 Hz rated load, tolerance +3 dB [Pa] [dB] Axial 701) [m3/s] [mm] 80 Air flow rate, min NDE DE IP55 0.02 95 IP55 0.04 110 IP55 0.09 140 IP55 0.16 731) 200 NDE DE IP23 0.21 732) 450 DE NDE IP55 0.17 550 NDE DE IP23 0.33 600 DE NDE IP55 0.31 DE NDE 100 NDE DE DE NDE 132 NDE DE DE NDE 160 NDE DE DE NDE 180 225 280 NDE DE IP23 0.52 DE NDE IP55 0.42 650 Radial 742) 600 600 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 65 Mechanical properties 3.1 Cooling 1) At a rated pulse frequency of 4 kHz and a speed range up to 5000 rpm 2) At a rated pulse frequency of 2 kHz and speed range * Forced ventilation (IP55) - SH180 up to 5000 rpm - SH225 up to 3500 rpm - SH280 up to 3300 rpm * Open-circuit ventilation (IP23) - SH180 up to 3000 rpm - SH225 up to 2000 rpm - SH280 up to 2800 rpm Note Ambient air If the ambient air is polluted by particles of dust or similar substances, the preferred air flow direction is NDE DE. As of SH132, the motors with air flow direction NDE DE are optionally available with an air filter (option G14). If an additional air filter is required for the three-phase external fan (option L75), the air filter must be ordered with option Q14 (can only be ordered for SH 180 and SH 225). Cleaning the cooling air ducts On air-cooled motors, you must regularly clean the cooling air ducts through which the ambient air flows. The degree of pollution depends on the location of use. Clean the air cooling ducts, for example, with dry, oil-free compressed air. Motors with pipe connection 1PH8 motors with "forced ventilation" can optionally be ordered for "pipe connection." The external fan, which is normally mounted as standard, is omitted in this version. A molded pipe connection replaces the external fan. The diameter of the pipe connection is based on the standard DIN EN 1506 or DIN EN 13180. This means that commercially available pipes and molded parts for airconditioning systems can be used. Note Minimum air flow and pressure drop Pipes and external fans of suitable type and dimensioning must be installed and connected. The required minimum air flow and the pressure drop at the motor must be taken into account for the design and dimensioning. 1PH8 main motors 66 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Mechanical properties 3.1 Cooling Table 3- 6 Diameter, minimum air flow and pressure drop Shaft height [mm] Diameter [mm] Degree of protection Minimum air flow [m3/s] Pressure drop [Pa] 80 150 IP55 0.02 95 100 160 IP55 0.04 110 132 224 IP55 0.09 140 160 280 IP55 0.16 200 180 300 IP23 0.21 450 IP55 0.17 550 IP23 0.33 600 IP55 0.31 650 IP23 0.52 600 IP55 0.42 600 225 280 3.1.3 350 Adapter required Water cooling WARNING Defective work on the cooling circuit Defective work on the cooling circuit can cause injury and/or damage to property. * Only qualified personnel may assemble, install, and commission the cooling circuit. * Perform installation or service work on the cooling circuit only when the system is deenergized. The electrochemical processes that take place in a cooling system must be minimized by choosing the right materials. For this reason, mixed installations, i.e. a combination of different materials, such as copper, brass, iron, or halogenated plastic (PVC hoses and seals), should not be used or should be limited to the absolutely essential minimum. There are 3 types of cooling circuits: Closed cooling circuit Semi-open cooling circuit Open cooling circuit 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 67 Mechanical properties 3.1 Cooling Table 3- 7 Description of the various cooling circuits Definition Description Closed cooling circuit The pressure equalizing vessel is closed (oxygen cannot enter the system) and has a pressure relief valve. The coolant is only routed in the motors and converters as well as the components required to dissipate heat. Semi-open cooling circuit Oxygen can only enter the cooling system through the pressure equalization vessel, otherwise the same as "closed cooling circuit." Open cooling circuit (tower system) The coolant is cooled in a tower. In this case, there is intensive oxygen contact. Note Cooling circuits Only closed and semi-open cooling circuits are permissible for motors. Converter systems must be connected before the motors in the cooling circuit. 1) 1 Filter 1) 2 Flow meter 1) 3 Pressure relief valve, setting valve flow rate 4 Pump 5 Cooling water tank 1) 6 Temperature measurement cooling water 7 Compressor / cooling unit 8 Cooling unit 9 Motor These components are not absolutely necessary. Figure 3-1 Example of a semi-open cooling circuit 1PH8 main motors 68 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Mechanical properties 3.1 Cooling Equipotential bonding Provide all components in the cooling system (motor, heat exchanger, piping system, pump, pressure equalization tank, etc.) with equipotential bonding. Implement the equipotential bonding using a copper rail or finely stranded copper cable with the appropriate conductor cross-sections. Note Installation of the cooling water pipes Electrically conductive cooling water pipes must not come into contact with live components. * Ensure adequate insulation. * Securely fasten the pipe. Materials used in the motor cooling circuit The materials used in the cooling circuit must be coordinated with the materials in the motor. Table 3- 8 Materials used in the cooling circuit of the 1PH8 motor Shaft height Bearing shield Pipes in the stator (designation) 80 Cast iron (EN-GJL-200) Stainless steel 100 Cast iron (EN-GJL-200) Stainless steel 132 Cast iron (EN-GJL-200) Stainless steel 160 Cast iron (EN-GJL-200) Stainless steel 180 - Stainless steel (V4A) 225 - Stainless steel (V4A) 280 - Stainless steel (V4A) Materials and components in the cooling circuit The following table lists a wide variety of materials and components which may or may not be used in a cooling circuit. Table 3- 9 Materials and components of a cooling circuit Material Used as Description Zinc Pipes, valves and Use is not permitted. fittings Brass Pipes, valves and Can be used in closed circuits with inhibitor. fittings Copper Pipes, valves and Can be used only in closed circuits with inhibitors in which the fittings heat sink and copper component are separated (e.g. connection hose on devices). 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 69 Mechanical properties 3.1 Cooling Material Used as Description Common steel (e.g. St37) Pipes Permissible in closed circuits and semi-open circuits with inhibitors or Antifrogen N, check for oxide formation, inspection window recommended. Cast steel, cast iron Pipes, motors Closed circuit and use of strainers and flushback filters. Fe separator for stainless heat sink. High-alloy steel, Group 1 (V2A) Pipes, valves and Can be used for drinking or municipal water with a chloride confittings tent up to <250 ppm, suitable according to definition in Section "Coolant definition". High-alloy steel, Group 2 (V4A) Pipes, valves and Can be used for drinking or municipal water with a chloride confittings tent up to <500 ppm, suitable according to definition in Section "Coolant definition". ABS (AcrylnitrileButadieneStyrene) Pipes, valves and Suitable according to the definition in Section "Coolant definifittings tion". Suitable for mixing with inhibitor and/or biocide as well as Antifrogen N. Installation comprising different materials (mixed installation) Pipes, valves and Use is not permitted. fittings PVC Pipes, valves, fittings and hoses Hoses Use is not permitted. Reduce the use of hoses to a minimum (device connection). Must not be used as the main pipe for the whole system. Recommendation: EPDM hoses with an electrical resistance > 109 (e.g. Semperflex FKD supplied from Semperit or DEMITTEL; from PE/EPD, supplied from Telle). Gaskets Pipes, valves and Use of Viton, AFM34, EPDM is recommended. fittings Hose connections Transition Hose - pipe Secure with clips conforming to DIN 2817, available e.g. from the Telle company. The following recommendation applies in order to achieve an optimum motor heatsink (enclosure) lifetime: Engineer a closed cooling circuit with cooling unit manufactured out of stainless steel that dissipates the heat through a water-water heat exchanger. All other components such as cooling circuit cables and fittings manufactured out of ABS, stainless steel or general construction steel. Cooling system manufacturers BKW Kalte-Warme-Versorgungstechnik GmbH http://www.bkw-kuema.de DELTATHERM Hirmer GmbH http://www.deltatherm.de Glen Dimplex Deutschland GmbH http://www.riedel-cooling.com Helmut Schimpke und Team Industriekuhlanlagen http://www.schimpke.org GmbH + Co. KG Hydac System GmbH http://www.hydac.com Hyfra Industriekuhlanlagen GmbH http://www.hyfra.de KKT Kraus Kalte- und Klimatechnik GmbH http://www.kkt-kraus.de 1PH8 main motors 70 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Mechanical properties 3.1 Cooling Pfannenberg GmbH http://www.pfannenberg.com Rittal GmbH & Co. KG http://www.rittal.de Note Other manufacturers You can also use equivalent products from other manufacturers. Responsibility for the properties of third-party products resides with the plant manufacturer. Consider the following pressure conditions when designing the cooling circuit. Permissible pressure Define the working pressure based on the flow conditions in the supply and return pipes of the cooling circuit. Set the required cooling water flow rate per time unit as appropriate for the technical specifications of the equipment and motors. The maximum permitted pressure in the cooling circuit is 0.6 MPa (6 bar). Note If you use a pump that reaches a higher pressure, maintain a maximum pressure of 0.6 MPa by taking appropriate measures (pressure relief valve, pressure control, etc.). Design the cooling circuit to have the smallest possible pressure difference between the supply and return pipes so that pumps with a shallow characteristic curve can be used. Design the cooling circuit with a self-cleaning filter to avoid blockage and corrosion. 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 71 Mechanical properties 3.1 Cooling Pressure drop in the motor Figure 3-2 Pressure drop in the cooling pipe system, shaft heights 80 to 132 Figure 3-3 Pressure drop in the cooling pipe system, shaft height 160 1PH8 main motors 72 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Mechanical properties 3.1 Cooling Figure 3-4 Pressure drop in the cooling pipe system, shaft height 180 Figure 3-5 Pressure drop in the cooling pipe system, shaft height 225 Figure 3-6 Pressure drop in the cooling pipe system, shaft height 280 Note Ensuring adequate cooling In order to ensure adequate cooling, the flow volumes must correspond to the minimum values specified in section "Cooling data and sound pressure levels"! 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 73 Mechanical properties 3.1 Cooling Pressure equalization If various components are connected up in the cooling circuit, it may be necessary to provide pressure equalization. Note Arrangement of the reactor element Flow restrictors must be mounted on the cooling water outlet of the motor or the relevant component! Avoiding cavitation During uninterrupted duty, the pressure drop across a converter or motor must not exceed 0.2 MPa (2 bar). Otherwise, the high flow rate results in damage due to cavitation and/or abrasion. Connecting motors in series For the following reasons, Siemens only conditionally recommends connecting motors in series: The required flow rates of the motors must be approximately the same (< a factor of 2) An increase in the cooling water temperature can result in having to derate the second or third motor if the maximum cooling water inlet temperature is exceeded. Cooling water inlet temperature Note Cooling water inlet temperature Select the cooling water inlet temperature so that condensation does not form on the surface of the motor. Cooling water temperatures which are lower than the ambient temperature tend to result in increased water condensation. The difference between the cooling water inlet temperature and the ambient temperature depends on the relative air humidity. For instance, 50 % air humidity at an ambient temperature of 40 C corresponds to a temperature difference of 10 K: Tcool > Tambient - temperature difference Please note that you must also shut off the flow of cooling water when the motor is not operational for prolonged periods of time. 1PH8 main motors 74 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Mechanical properties 3.1 Cooling The motors are designed for operation up to a cooling water inlet temperature of +30 C, provided that all of the specified motor data is complied with. If the cooling water inlet temperature deviates from this, the continuous torque will change (see table "Derating factors"). Table 3- 10 Derating factors Installation altitude above sea level [m] Cooling water inlet temperature 30 C 35 C 40 C 45 C 1,000 1.00 0.95 0.90 0.84 1,500 0.97 0.92 0.87 0.81 2,000 0.93 0.88 0.84 0.78 2,500 0.91 0.86 0.82 0.76 3,000 0.89 0.85 0.80 0.75 3,500 0.87 0.83 0.78 0.73 4,000 0.85 0.81 0.77 0.71 Cooling data and sound pressure levels The specified values refer to operation at the rated speed with rated torque. The cooling water temperature must be 30 C. Table 3- 11 Cooling data and sound pressure levels Shaft height Flow volume, min [l/min] Pressure drop Sound pressure level LpA (1 m) Motor rated load, tolerance +3 dB [bar] [dB] Thread connection at NDE [inches] 80 6 0.6 G 1/8 100 8 0.4 132 12 0.9 160 15 0.2 69 180 (1PH8184) 15 0.6 70 2) 180 (1PH8186) 15 0.7 G3/8 225 (1PH822.-1) (asynchronous) 20 0.6 G 3/8 225 (1PH822.-2) (synchronous) 25 0.9 70 3) G 3/8 280 35 0.6 72 3) G 1/2 68 1) G 1/4 G 3/8 1) G1/2 G 3/8 1) at a rated pulse frequency of 4 kHz and a speed range up to 5000 rpm 2) at a rated pulse frequency of 2 kHz or 4 kHz and speed ranges for SH 180 of up to 5000 rpm SH 225 of up to 4500 rpm 3) at a rated pulse frequency of 2 kHz and speed ranges for SH 225 of up to 4500 rpm SH 280 of up to 3300 rpm 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 75 Mechanical properties 3.1 Cooling Heat loss to be dissipated The values for the heat loss to be dissipated are specified according to the rated point in Chapter "Technical tables and characteristics." Water specification Cooling water quality The values specified for the cooling water correspond to the requirements for a closed cooling circuit. Not all specified concentrations will occur in the cooling water at the same time. A filter can be used to ensure smooth operation. The grade of filtration should be no less than 100 m. Cooling water inlet temperature The maximum cooling water inlet temperature is 30 C (86 F) Cooling water specifications Table 3- 12 Cooling water specifications (SH 80 to 160) Component Quality of the water used as coolant for motors with stainless steel pipes + cast iron or steel jacket pH value 6 ... 9 Total hardness < 170 ppm Electrical conductivity < 500 S/cm Chloride ions < 40 ppm, can be achieved by adding deionized water. Sulfate ions < 50 ppm Nitrate ions < 50 ppm Dissolved solids < 340 ppm Maximum particle size < 100 m Operating pressure < max. 6 bar Pressure drop at V(N) < 1 bar Inlet temperature < 30 C Anti-freeze protection / corrosion protection 20 ... 30 % NALCO 00GE056 inhibitor 0.2 ... 0.25% Table 3- 13 Cooling water specifications (SH 180 to 280) Component Quality of the water used as coolant for motors with stainless steel pipes pH value 6 ... 9 Total hardness < 170 ppm Electrical conductivity < 2000 S/cm 1PH8 main motors 76 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Mechanical properties 3.1 Cooling Component Quality of the water used as coolant for motors with stainless steel pipes Chloride ions < 250 ppm, can be obtained by adding deionized water. Sulfate ions < 240 ppm Nitrate ions < 50 ppm Dissolved solids < 340 ppm Maximum particle size < 100 m Operating pressure < max. 6 bar Pressure drop at V(N) < 1 bar Inlet temperature < 30 C Anti-freeze protection / corrosion protection 20 ... 30 % NALCO 00GE056 inhibitor 0.2 ... 0.25% Note Deionized water (for Cooling water specifications tables) We recommend using deionized water with reduced conductivity (5 ... 10 S/cm). If necessary, ask your water utility to provide the values. According to 98/83/EC, drinking water may contain up to 2500 ppm of chloride! Manufacturers of chemical additives can provide support when analyzing the water that is available on the plant side. Note Inhibitor (for Cooling water specifications tables) The inhibitor is not required if it ensured that the concentration of Antifrogen N is > 20%. Derating is required for an anti-freeze content of > 30% Biocide Closed cooling circuits with soft water are susceptible to microbes. The risk of corrosion caused by microbes is virtually non-existent in chlorinated drinking water systems. Antifrogen N has a biocidal effect even at the minimum required concentration of > 20 %. No strain of bacteria can survive if >20 % Antifrogen N is added. The suitability of a biocide depends on the type of microbe. The following types of microbes are encountered in practice: Slime-forming bacteria Corrosive bacteria Iron-depositing bacteria 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 77 Mechanical properties 3.1 Cooling At least one water analysis per annum is recommended to determine the number of bacterial colonies. Suitable biocides are available from the manufacturer Nalco for example. The manufacturer's recommendations must be followed regarding the concentration and compatibility with any inhibitor used. Note Compatibility of coolant additives Biocides and Antifrogen N must not be mixed. There are other manufacturers of chemical additives in the market. Equivalent products from other manufacturers may be used. The suitability must be checked by testing. Other coolants (not water-based) When using other coolants (e.g. oil, cooling lubricating medium) derating may be required in order that the thermal motor limit is not exceeded. The derating can be determined using the following data at a temperature of 30 C: Density [kg/m3] Specific thermal capacitance c [J/(kg*K)] Thermal conductivity [W/(K*m)] Kinematic viscosity [m2/s] Flow rate V [rpm] Please send your enquiry to Technical support. Note Power reduction when using a different coolant Derating is required for water-oil mixtures with more than 10% oil. Manufacturers of chemical additives Tyforop Chemie GmbH http://www.tyfo.de Clariant Produkte Deutschland GmbH http://www.antifrogen.de Cimcool Industrial Products http://www.cimcool.net FUCHS PETROLUB AG http://www.fuchs-oil.com Hebro chemie GmbH http://www.hebro-chemie.de HOUGHTON Deutschland GmbH http://www.houghton.com Nalco Deutschland GmbH http://www.nalco.com Schweitzer-Chemie GmbH http://www.schweitzer-chemie.de 1PH8 main motors 78 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Mechanical properties 3.1 Cooling Information regarding third-party products Note Recommendation relating to third-party products This document contains recommendations relating to third-party products. Siemens accepts the fundamental suitability of these third-party products. You can use equivalent products from other manufacturers. Siemens does not accept any warranty for the properties of third-party products. Maintenance and service It is recommended that the filling level and discoloration or cloudiness of the cooling water is checked at least once a year. Furthermore, every year it must be checked that the cooling water still meets the permissible specification. If the cooling water level has dropped, the loss should be corrected on closed or semi-open circuits with a prepared mixture of deionized water and inhibitor or Antifrogen N. The motor is connected to the cooling circuit by means of two female threads on the rear of the motor. Which one is the inlet and which one is the outlet can be freely connected. Coolant connection: See table "Cooling data and sound pressure levels" The units should be connected with hoses to provide mechanical decoupling (refer to the table "Materials and components of a cooling circuit"). Commissioning When required, before connecting the motors and converters to the cooling circuit, the pipes should be flushed in order to avoid dirt entering the motors and converters. After the units have been installed in the plant, the coolant circuit must be commissioned before the electrical systems. 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 79 Mechanical properties 3.2 Degree of protection 3.2 Degree of protection Degree of protection designation The degree of protection designation in accordance with EN 60034-5 (IEC 60034-5) is described using the letters "IP" and two digits (e.g. IP64). IP = International Protection 1st digit = protection against ingress of foreign bodies 2nd digit = protection against harmful ingress of water When assigning motors to a specific degree of protection class, a standardized, brief test procedure is applied. This can deviate significantly from the actual ambient conditions where the motor is installed. Attention must be paid to providing suitable sealing of the motor shaft for the selected degree of protection for the motor. Note Suitability of the motor depending on the ambient conditions Depending on these ambient conditions - such as the chemical properties of dusts or the cooling media used at the installation site - it is only conditionally possible to evaluate the suitability of the motor for the particular environment using the degree of protection (e.g. electrically conductive dusts or aggressive coolant vapors or liquids). In these cases, the motor must be additionally protected using the appropriate measures. Note Liquids that have collected and/or oil jets Liquid must be prevented from collecting on the motor shaft as well as jets of oil (or are not permissible at all) - even for versions with radial shaft sealing ring. 1PH8 main motors 80 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Mechanical properties 3.2 Degree of protection Degrees of protection The degrees of protection which are available for the 1PH8 motor series are listed in the following table. Table 3- 14 Description of degrees of protection Motor Degree of protection 1st code number 2nd code number Touch protection Protection against ingress of solid foreign bodies Forced ventilation IP23 (open-circuit ventilation) Protection against finger contact Protection against mediumsized, solid foreign bodies above 12 mm Protection against spray water up to 60 from the vertical Forced ventilation (surface cooling) IP55 Full protection against contact Protection against damaging dust deposits Splashwater from any direction Water cooling IP65 Full protection against contact Protection against dust Splashwater from any direction Note Routing cables in humid/moist environments If the motor is mounted in a humid environment, the power and signal cables must be routed as shown in the following figure. Figure 3-7 Principle of cable routing in a wet/moist environment 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 81 Mechanical properties 3.3 Construction types 3.3 Construction types For correct motor selection, the following types of construction according to EN 60034-7 (IEC 60034-7) apply: 1) Fixing on the flange and feet is necessary. Figure 3-8 Types of construction You will find the available types of construction in Chapter "Selection and ordering data." 1PH8 main motors 82 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Mechanical properties 3.4 Types of bearing 3.4 Types of bearing 3.4.1 Drive output types and bearing versions 1PH8 motors are suitable for coupling output and belt coupling. The bearing versions and their applications are summarized in the following table. Table 3- 15 Drive output type with the appropriate bearing design Application * Coupling output * Planetary gearboxes, low radial forces * Belt coupling with normal radial force * Pinion output with straight teeth * Belt coupling with increased radial force Bearing version SH 80 to 160 SH 180 to 280 SH 100 to 160 SH 180 to 280 1) Deep-groove ball bearing 2) Cylindrical-roller bearings (only in versions for increased radial forces - 14th data position = E or F) 3) For the bearing version G or H as a floating bearing (as for 1PH7); all other bearing types have a location bearing at the drive end - 14th data position = A, B, C, D, F, L, M, P, Q, or N 4) Version as a location bearing 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 83 Mechanical properties 3.4 Types of bearing Bearing version, maximum speed and bearing change intervals Table 3- 16 Shaft height 80 Bearing version, maximum speed and bearing change intervals Bearing version Maximum speed Average operating speed nmax [rpm] nm [rpm] Standard with locating bearing: 10,000 Standard with locating bearing: Statistical bearing service life Recommended bearing change interval tLW [h] L10h [h] Permanent lubrication Relubrication 8000 20,000 20,000 - 12,000 8500 12,000 12,000 - Standard 10,000 6000 20,000 20,000 - Performance 15,000 11,500 12,000 12,000 - High Performance 20,000 13,000 12,000 12,000 - Advanced Lifetime 5,000 3500 40,000 40,000 - Standard with locating bearing: 9,000 7000 20,000 20,000 - Standard with locating bearing: 10,000 7300 12,000 12,000 - and option L37 100 and option L37 132 160 Standard 9,000 5000 20,000 20,000 - Performance 12,000 10,500 12,000 12,000 - High Performance 18,000 11,500 12,000 12,000 - Advanced Lifetime 5,000 3000 40,000 40,000 - Increased radial forces 7,000 2300 20,000 20,000 - Standard with locating bearing: 8,000 6500 20,000 20,000 - Standard 8,000 4500 20,000 20,000 - Performance 10,000 8500 12,000 12,000 - High Performance 15,000 10,000 12,000 12,000 - Advanced Lifetime 4,500 2500 40,000 40,000 - Increased radial forces 6,500 1800 20,000 20,000 - Standard with locating bearing: 6,500 5400 20,000 20,000 - Standard 6,500 3500 20,000 20,000 - Performance 9,000 7000 12,000 12,000 - High Performance 10,000 8000 12,000 12,000 - Advanced Lifetime 4,000 2300 40,000 40,000 - Increased radial forces 5,300 1500 16,000 16,000 - 1PH8 main motors 84 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Mechanical properties 3.4 Types of bearing Shaft height Bearing version 180 nm [rpm] Standard with locating bearing: 5000 (3000)2) 2000 Increased radial forces 5000 (3000)2) Statistical bearing service life Recommended bearing change interval tLW [h] Permanent lubrication Relubrication 40,000 (24,000)1) 20,000 40,000 (24,000)1) 2000 20,000 (12,000)1) 12,000 20,000 (12,000)1) 7,500 5000 20,000 12,000 20,000 Standard with locating bearing: 4500 (2500)2) 1800 40,000 (24,000)1) 20,000 40,000 (24,000)1) Increased radial forces 4500 (2500)2) 1800 20,000 (12,000)1) 12,000 20,000 (12,000)1) Performance 280 Average operating speed nmax [rpm] Performance 225 Maximum speed L10h [h] 6,000 4000 20,000 12,000 20,000 Standard with locating bearing: 3300 (2000)2) 1500 40,000 (24,000)1) 20,000 40,000 (24,000)1) Increased radial forces 3300 (2000)2) 1500 20,000 (12,000)1) 12,000 20,000 (12,000)1) 1) When vertically mounted 2) For types of construction IM V3, IM B5, and IM V1 You can calculate the average operating speed nm for alternating bearing load by the following formula: Formula symbol Unit Description t1 ... tn % Time percentage of the bearing load n1 ... nn min-1 Operating speed You therefore calculate an average speed from the different speeds according to their time percentages. Table 3- 17 Recommended bearing change intervals at maximum speed Shaft height 80 100 Bearing version Maximum speed Statistical bearing service life Recommended bearing change interval tLW [h] nmax [rpm] L10h [h] Permanent lubrication Relubrication Option L37 12,000 8,000 8,000 - Performance 15,000 8,000 8,000 - High Performance 20,000 8,000 8,000 - Option L37 10,000 8,000 8,000 - Performance 12,000 8,000 8,000 - High Performance 18,000 8,000 8,000 - 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 85 Mechanical properties 3.4 Types of bearing Shaft height 132 160 Table 3- 18 Bearing version Maximum speed Statistical bearing service life Recommended bearing change interval nmax [rpm] L10h [h] Permanent lubrication Relubrication Performance 10,000 8,000 8,000 - High Performance 15,000 8,000 8,000 - Performance 9,000 8,000 8,000 - High Performance 10,000 8,000 8,000 - tLW [h] "Premium Performance" bearing version, maximum speed and bearing change intervals Shaft height Maximum speed nmax [rpm] Average operating speed nm [rpm] Recommended bearing change interval tLW [h] with sealing air without sealing air (Option Q12) 80 24,000 16,000 12,000 19,200* 10,000 8,000 24,000 7,000 4,000 Speed backlash with: t1 = 10 min, n1 = 0 t2 = 30 min, n2 = 16,000 rpm t3 = 60 min, n3 = 24,000 rpm Note Difficult operating conditions in operation at nmax Under difficult operating conditions, the bearing replacement intervals tLW are reduced by up to 50 %. Difficult operating conditions include * large vibrations and shocks * frequent reversing operation 1PH8 main motors 86 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Mechanical properties 3.4 Types of bearing Note Reduced maximum motor speeds The maximum speeds might be reduced on motors with integrated encoder as a result of mechanical conditions or limitations imposed by signal conditioning capacity. The reduced maximum speeds can be found in the table "Encoder types for motors with DRIVE-CLiQ" in Chapter Encoder assignment as a function of maximum permissible speeds (Page 163). Note Permanently switching on the sealing air For the "Premium Performance" bearing version, Siemens recommends that the sealing air be permanently switched on during continuous operation at nmax. Sealing air connection and conditioning are described in Chapter "Sealing air connection (option Q12) (Page 174)." 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 87 Mechanical properties 3.4 Types of bearing 3.4.2 Bearing lifetime The bearing lifetime is limited by material fatigue (fatigue service life) and/or lubrication failure (grease service life). The fatigue lifetime (statistical bearing lifetime L10h) mainly depends the mechanical load. The correlation is shown in the radial force/axial force diagrams. The values are determined according to DIN/ISO 281. The grease lifetime is mainly dependent on the bearing size, speed, temperature as well as the vibrational load. The grease lifetime can be extended by especially favorable operating conditions (low or average speed, low bearing temperatures, low radial force or vibration load). A reduction of the grease lifetime can be expected for difficult operating conditions and when motors are mounted vertically. Lifetime lubrication (without relubrication) Note For lifetime lubrication, the grease lifetime is harmonized with the bearing lifetime L10h. Bearing change interval (tLW) The recommended bearing change intervals are obtained from the inter-dependencies mentioned above for a specific operating point such as: Coupling output or belt coupling Coolant temperature up to max. +40 C (forced ventilation) Cooling water inlet temperature up to max. +30 C (water cooling) Complying with the permissible radial and axial forces (refer to Chapter "Radial and axial forces") 1PH8 main motors 88 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Mechanical properties 3.4 Types of bearing Complying with the maximum permissible speeds (refer to Chapter "Technical data and characteristics") The bearing change intervals are reduced for unfavorable operating conditions, for example - average speed more than the value specified in Table 3-16 - continuous operation at nmax - Vibration and shock load - Frequent reversing operation Note Replacing the motor bearings When replacing the motor bearings, we also recommend that encoders with their own bearings are also replaced. The fatigue life and the grease consumption time are calculated, statistical values and cannot be warranted. Note Axial bearing loads for vertical mounting The increased axial loads imposed on the bearings on vertically mounted motors can reduce the bearing lifetime by almost 50%. This applies to shaft heights 180 to 280 due to the rotor weights. Relubrication In motors that can be relubricated, the bearing life can be extended by complying with fixed relubrication intervals. Depending on the frame size, some restrictions have to be taken into account - e.g. vertical mounting/shaft position. It is possible to relubricate motors, shaft heights 180 and 225. A lubricating nipple is optionally provided, Code K40. 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 89 Mechanical properties 3.4 Types of bearing Relubrication intervals Relubrication intervals are specified: on the lubrication plate of the motor in the table "Relubrication intervals" Note Longer time periods between delivering and commissioning the motor For longer periods of time (e.g. longer than 1 relubrication interval) between shipping and commissioning the motor, the bearings must be lubricated. When relubricating, the shaft must be rotated in order to distribute the grease around the bearings (for additional information, see the Operating Instructions). The values specified in the table below apply to the same conditions as are described above for bearing change intervals: Table 3- 19 Shaft height Relubrication intervals Bearing version Relubrication interval in operating hours4) [h] 180 225 280 Quantity of grease for each relubrication operation1) Grease chamber2) Possible number of relubrication intervals 3) [g] [g] Standard 7,000 15 80 5 Increased radial forces 4,000 20 80 4 Performance 4,000 15 80 5 Standard 7,000 30 180 6 Increased radial forces 4,000 40 180 4 Performance 4,000 30 180 6 Standard 7,000 40 400 10 Increased radial forces 4,000 50 400 8 1) Grease quantity for relubrication for normal conditions (ambient temperature up to 40C, horizontal mounting. 2) Holding capacity of the grease chamber with precise adherence to the grease quantity for each relubrication interval. 3) Calculated number of re-lubricating intervals; the bearing lifetime is specified statistically by means of the L10h definition. 4) Relubricating intervals must be halved for vertically mounted units. 1PH8 main motors 90 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Mechanical properties 3.4 Types of bearing Note Adapting relubricating intervals Unfavorable factors such as the effects of mounting/installation, speed or mechanical loads require that the relubricating intervals are appropriately adapted. Situations such as these require special consideration or must be be calculated - and must be engineered according to the limitations and constraints together with the responsible motor plant. The increased axial loads imposed on the bearings on vertically mounted motors can reduce the bearing lifetime by almost 50%. This applies to shaft heights 180 to 280 due to the rotor weights. A check which takes into account the relevant boundary conditions must be performed on SH 280 in the relevant motor factory. 3.4.3 NDE bearings, insulated version (option L27) Relevant, additional bearing currents When compared to a pure sinusoidal supply, the pulsed output voltage of a frequency converter results in additional motor bearing currents. The relevant additional bearing currents are: Circulating currents EDM currents Rotor ground currents Factors that influence bearing currents Above a certain magnitude, bearing currents result in localized melting at the bearing rings and rolling assemblies as well as lubricant wear. This reduces the bearing lifetime. Essential influencing factors include: Motor speed and associated operating time Pulse frequency of the frequency converter Grounding relationships between the motor and the connected load 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 91 Mechanical properties 3.4 Types of bearing Application for option L27 At speeds < 500 rpm, the load due to bearing currents increases significantly. Option L27 is always required if the motor is operated in the speed range between 0 ... 500 rpm for a longer period of time. Without option L27, the total operating time in the speed range 0 ... 500 rpm may be a maximum of 800 h (for an assumed bearing change interval (tLW) of the bearings of 20,000 h. Table 3- 20 Measures that are required for operation in the speed range < 500 rpm Shaft height Bearing change interval (tLW) for lifetime lubrication [h] 1) Options that are required Remarks - Due to the experience from the field (in practice) no dangers have been identified due to bearing currents 80 - 160 20000 180 L27 Insulated NDE bearings 225 _ Generally insulated NDE bearings 280 _ Generally insulated NDE bearings 1) Definition, refer to the table "Recommended bearing change intervals" Motor grounding In order to avoid rotor ground currents, the motor frame should be well grounded - e.g. by using shielded motor cables. The motor cable shield should be connected at both ends through the largest possible surface area. For specific applications, the grounding of the motor Zhg can be more unfavorable than the grounding of the connected loads Zrg, e.g. for long motor cables and when the motor is mounted in an insulated fashion. In this case, the capacitive discharge (leakage) current of the motor flows from the motor frame through the motor shaft to the connected load and from there to ground. Figure 3-9 Bearing current due to the grounding situation (=rotor ground current) The rotor ground current should be avoided by using an electrically insulating coupling. If such a coupling cannot be used for mechanical reasons, then the motor frame must be connected to the load through the largest possible surface area. The capacitive discharge (leakage) current then flows from the motor frame to the load and not through the bearings. 1PH8 main motors 92 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Mechanical properties 3.4 Types of bearing The connection between the motor frame and load is only effective if it represents an extremely low impedance for the high-frequency discharge (leakage) current. To achieve this, use several flat straps, e.g. grounding straps, metal plates. Figure 3-10 Connection between the motor frame and load to avoid rotor ground currents 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 93 Mechanical properties 3.5 Shaft end 3.5 Shaft end The DE shaft end is cylindrical in accordance with DIN 748 Part 3 (IEC 60072-1). 3.6 Mounting of rotating unions on 1PH8 hollow-shaft motors General information 1PH8 main motors with a hollow shaft (13th position in the Article No.: " 3 ") are designed as main spindle motors for machine tools and machining centers with internal tool cooling. A rotating union is required for the provision of the coolant in the rotating motor shaft. A rotorsupported or, for a motor ordered with option Y64, a bearingless, frame-supported rotating union can be mounted on the NDE shaft extension. In addition to coolant, suitable rotating unions can also transfer oil mist (minimum quantity lubrication), cutting oils or even compressed air at standstill. Rotor-supported rotating unions consist of the following components: Rotor with bearing Stator Enclosure with cable connections Floating-ring shaft seal Rotor-supported rotating unions are easy to fit and change. They are screwed into the motor shaft via the thread on the rotor. The advantage of these rotating unions is the leading off of the leakage via the housing and the integrated leakage connection. Bearingless, frame-supported rotating unions are made up of two separate parts, the rotating part with a mechanical seal and the static part with a mechanical seal and supply connection. By eliminating the bearings, higher speeds can be achieved and the rotating union is less sensitive to vibrations and lateral loads. However, an adapter such as is described in Ch. "Suggestion for an adapter for bearingless, frame-supported rotating unions" for installing the rotating union is required. Installation must be performed very carefully because the sealing surfaces of the mechanical seal are not protected. The rotating part is bolted into the NDE end of the motor shaft. The static part is mounted on the encoder cover of the motor via an adapter. The adapter must include a facility for draining leakage. The adapter must be designed in such a way that the motor is not flooded by the leakage and the degree of protection of the motor is complied with. It may be necessary to use sealing air. For use of a bearingless rotating union, the motor must be ordered with option Y64 and the interface on the encoder cover must be located concentrically with respect to the shaft. The mounting conditions stated by the manufacturer of the rotating union must be met. Depending on the type of rotating unions, the sealing rings may be permanently or temporarily in contact. Example of a closed seal: DEUBLIN series 1116 and 1108 Example of an opening seal: DEUBLIN series 902 and 1109 1PH8 main motors 94 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Mechanical properties 3.6 Mounting of rotating unions on 1PH8 hollow-shaft motors With opening seals, the sealing surfaces are separated when there is no coolant pressure, e.g. during a tool change. In this case, coolant runs out of the supply line and out of the motor shaft through the opened seal. This leakage and also the leakage due to wear of the sealing rings must be guided away via the leakage lines. NOTICE Motor failure due to incorrectly mounted leakage line If the leakage line does not lead downward, the leakage can flood the rotating union and the motor. This can result in failure of the rotating union and motor. To ensure the leakage is led away, the leakage line must always lead downward so that nothing can flow back. * When mounting, ensure that the leakage line always leads downward. NOTICE Axial forces due to coolant pressure Coolant under high pressure (usually 40 to 90 bar) flows via the mounted rotating union through the sequence of holes in the drive train: * Rotating union * Motor * Spindle * Tool. Due to the different hole diameters and the gap, different cross sections (areas) occur along the coolant flow, which can produce axial forces due to the coolant pressure. These can be 4 to 12.7 N/mm2, depending on the coolant pressure. 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 95 Mechanical properties 3.6 Mounting of rotating unions on 1PH8 hollow-shaft motors Figure 3-11 Mounting the rotating union Figure "Mounting the rotating union," illustrates how an axial force arises due to joint pressure, for example, in the gap between the motor shaft (hole bolt) and the spindle shaft. This acts upon the motor shaft against the bearing preloading force Fc. This reduces or even eliminates the preloading force of the motor bearing. For bearingless, frame-supported rotating unions, axial forces can also arise depending on the internal differing hole diameters. These act against the forces from the joint, so they have a smaller effect on the bearing preloading force. Ensure that the axial forces from the rotating union are greater than those from the joint (see case 1 in the graphic). This has the advantage that the bearing preloading force remains unchanged. The bearing preloading force is important for non-slip running of the motor bearing and must not be eliminated. 1PH8 main motors 96 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Mechanical properties 3.6 Mounting of rotating unions on 1PH8 hollow-shaft motors This advantage does not apply to rotor-supported rotating unions. It is important to ensure that the preloading force of the motor bearing is not eliminated (see figure "Mounting the rotating union" case 2). The axial force toward the motor must not be in the interval FAZ = Fc +/- 25% for horizontally mounted motors and FAZ = (Fc +/-25%) + FL for vertically mounted motors with the shaft extension pointing downward. For maximum permissible axial forces at the shaft extension, the specifications stated in Chapter "Radial and axial forces" apply. The axial forces that act in the rotating union must be requested from the manufacturer. Hollow shaft version Table 3- 21 Hollow shaft version Thread on DE 3.6.1 1PH808 1PH810 ... 1PH816 M12 x 1.25-RH M16 x 1.5-RH Centering on DE 16H7 20H7 Thread on NDE M12 x 1.25-LH M16 x 1.5-LH Centering on NDE 14 +0.008/+0.001 18 +0.007/-0.003 Through-hole 8 11.5 Key surface NDE SW19 SW27 Rotor-supported rotating union NOTICE Leaks in the rotating union If there are leaks in the rotating union and the hoses, the motor may be flooded and fail! * Avoid leaks in the rotating union. Note the following points when mounting the rotating union: When you mount the rotating union, pay attention to special aspects that differ between air-cooled and water-cooled motors. When installing the rotating union, observe the manufacturer's data. Mounting on water-cooled motors Water-cooled motors have a "2" in the 11th position in the Article No. With water-cooled motors, you can mount the rotating union directly on the motor. Use rotating unions with radial or axial connections. 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 97 Mechanical properties 3.6 Mounting of rotating unions on 1PH8 hollow-shaft motors Mounting rotor-supported rotating union on water-cooled motors Sealing cover Balancing disk Rotor-supported rotating union, e.g. DEUBLIN 1109-020-188 Leakage hose Inlet hose Mounting on air-cooled motors Air-cooled motors have a "0" or a "1" in the 11th position of the Article No. Air-cooled motors are equipped with an intermediate housing between the motor and the axially mounted fan. The intermediate housing is used to accommodate the rotating union. The intermediate housing is suitable for rotating unions with the following dimensions: Length up to 120 mm (without rotor connection thread and centering) Diameter up to 55 mm 1PH8 main motors 98 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Mechanical properties 3.6 Mounting of rotating unions on 1PH8 hollow-shaft motors Due to limitations of space, rotating unions with radial connections are advisable for aircooled motors, e.g. DEUBLIN 1109-020-188. Rotating unions with axial connections are not suitable! Mounting rotor-supported rotating unions on air-cooled motors Sealing cover Balancing disk Intermediate housing Rotor-supported rotating union, e.g. DEUBLIN 1109-020-188 Cutout Cover (openings for connections must be closed again) Leakage hose Inlet hose Fan 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 99 Mechanical properties 3.6 Mounting of rotating unions on 1PH8 hollow-shaft motors Note When air-cooled motors are connected, only rotating unions with a radial connection are used. Mounting steps Note Mounting steps for air-cooled motors The mounting steps 1, 11, 12, 13, and 14 are only required for air-cooled motors. 1. Remove the fan and intermediate housing from the motor. 2. If necessary, perform complete balancing of the motor using the exterior balancing disks. To do this, remove the sealing cover. Note Sealing cover * Remount the sealing cover after balancing. * The sealing cover is required to comply with the degree of protection. 3. Attach hoses for the inlet and leakage to the rotating union. Use angle elements if necessary. Note Rotating union to be used * Use a rotating union with radial connections. 4. Screw the rotating union into the NDE motor shaft extension. Tighten the rotating union with the correct tightening torque. For this, use the wrench grip surface on the NDE motor shaft extension to hold the other side. 5. Position the rotating union horizontally in such a way that the leakage connection is at the lowest point. 6. Always connect the hose for leakage sloping downward at least 15. 7. Also connect the hose for the inlet sloping downward. 8. If necessary, provide a ventilation hose for the leakage chamber. It equalizes the negative pressure caused by the fan. Lead the ventilation hose upward. 9. Manually check that the rotor turns easily. 10.Test the mounting under pressure for leaks. 11.Make a burr-free cutout in the intermediate housing for the inlet and leakage hoses. 1PH8 main motors 100 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Mechanical properties 3.6 Mounting of rotating unions on 1PH8 hollow-shaft motors 12.Push the intermediate housing with the cutout over the hoses. Screw the intermediate housing onto the motor. Protect the hoses from mechanical stresses. 13.Screw the fan onto the intermediate housing. 14.Seal the remaining openings between the cutout and the hoses. 3.6.2 Bearingless, frame-supported rotating union The bearingless frame-supported rotating union cannot be mounted directly on the motor. An adapter is required for the static part of the rotating union. The adapter is not included in the scope of delivery and must be made by the customer to match the rotating union to be used. Please follow the following design instructions: The adapter for holding the static part must be matched to the rotating union to be used. For this purpose, the dimensions of the manufacturer of the rotating union must be complied with. The adapter should be designed as shown in Chapter "Suggestion for an adapter for bearingless, frame-supported rotating unions". The gap between the adapter and the NDE shaft extension in the radial direction must be as small as possible (approx. 0.25mm) and be as long as possible in the axial direction so that exiting coolant cannot penetrate the motor. The leakage connections must be as large as possible and must be provided at the lowest point in the leakage chamber. The leakage connection (G3/8") located nearest the static part of the rotating union is for draining leakage away during operation. The second leakage connection (G1/4") is a backup for draining away increased leakage due to faults. NOTICE Monitoring the backup line To detect a fault in the rotating union in good time and to protect the motor from flooding, it is necessary to monitor the flow rate of the backup line. * Make sure that a signal is output in the event of leakage. * Make sure that the system (coolant supply) is switched off in case of a fault. The star-shaped drainage holes in the mounting surface with the encoder cover should be implemented as shown in Chapter "Suggestion for an adapter for bearingless, framesupported rotating unions" so that no liquid can penetrate the motor through the labyrinth seal between the encoder cover and the balancing disk. If the motor is mounted vertically, all 6 drainage holes should be opened; if the motor is mounted horizontally, it is enough to open the two lower drainage holes. 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 101 Mechanical properties 3.6 Mounting of rotating unions on 1PH8 hollow-shaft motors Note It is advantageous to provide a sealing air connection to protect the motor from penetration of coolant. The diameters and end faces of the adapter for supporting the encoder cover or the static part of the rotating union should be turned in one clamping if possible. For simpler machining, the adapter can be axially split. It is important that the finish-machining of the support diameter and end faces is performed in the assembled condition and in one clamping. Mounting on water-cooled motors Water-cooled motors have a "2" in the 11th position of Article No. together with option Y64. Rotating unions with radial or axial connections can be used. 1PH8 main motors 102 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Mechanical properties 3.6 Mounting of rotating unions on 1PH8 hollow-shaft motors Mounting a bearingless rotating union on a water-cooled motor 1 Encoder cover 2 Balancing disk 3 Adapter 4 6 x M5 bolts 5 Rotating part of the rotating union, e.g. DEUBLIN 1129-050-301 6 Static part of the rotating union, e.g. DEUBLIN 1129-050-301 7 Leakage hose (min. diam. 12mm inside) 8 Leakage hose as backup and for faults 9 Inlet hose 10 Sealing air connection 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 103 Mechanical properties 3.6 Mounting of rotating unions on 1PH8 hollow-shaft motors Mounting on air-cooled motors Air-cooled motors have a "0" or a "1" in the 11th position of Article No. together with option Y64. Air-cooled motors are equipped with an intermediate housing between the motor and the axially mounted fan. The intermediate housing is used to accommodate the rotating union. It is suitable for rotating unions up to a length (without rotor connection thread and centering) of 120mm and a diameter of up to 55mm. Due to limitations of space, rotating unions with radial connections are recommended for air-cooled motors, e.g. DEUBLIN 1129-050-301. Rotating unions with axial connections are also possible in short versions, e.g. DEUBLIN 1129-730-731. In that case, an angled element must be used on the axial connection to which the supply hose is connected. The dimension 120mm must not be exceeded with the angled element. NOTICE Sealing the remaining holes Seal the remaining holes again between the cutout and the hoses to ensure that motor cooling is still effective. 1PH8 main motors 104 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Mechanical properties 3.6 Mounting of rotating unions on 1PH8 hollow-shaft motors Mounting of bearingless rotating union on an air-cooled motor 1 Encoder cover 2 Balancing disk 3 Adapter 4 6 x M5 bolts 5 Rotating part of the rotating union, e.g. DEUBLIN 1129-050-301 6 Static part of the rotating union, e.g. DEUBLIN 1129-050-301 7 Leakage hose (min. diam. 12mm inside) 8 Leakage hose as backup and for faults 9 Inlet hose 10 Sealing air connection 11 Intermediate housing 12 Cutout 13 Cover (openings for connections must be closed again) 14 Fan 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 105 Mechanical properties 3.6 Mounting of rotating unions on 1PH8 hollow-shaft motors Mounting steps Note Mounting steps for air-cooled motors The mounting steps 1, 13, 14, 15, and 16 are only required for air-cooled motors. 1. Disassemble the fan and intermediate housing from the the motor. 2. Removing the sealing cover 3. If necessary, perform complete balancing of the motor with external balancing disks 4. Screw the rotating part of the rotating union into the NDE motor shaft extension and tighten with the appropriate torque (against the wrench grip surface on the NDE motor shaft extension). 5. Mount the adapter for the static part (not included in the scope of delivery) on the encoder cover with 6x M5 screws. Position the adapter in such a way that the leakage connection is at the lowest point (with horizontal mounting). 6. Mount the hoses for leakage and sealing air on the adapter, if necessary using angled elements 7. Mount the hose for the supply to the static part of the rotating union, if necessary using angled elements 8. Screw the static part onto the adapter 9. Always connect the hoses for leakage sloping downward (min. 15). 10.Also connect the hose for the inlet sloping downward. 11.Manually check that the rotor turns easily. 12.Perform a hydrostatic test for leaks 13.Make a cutout for the inlet and leakage hoses in the intermediate housing. 14.Push the intermediate housing with the inlet over the hoses and screw it to the motor. Protect the hoses from mechanical loads 15.Screw the fan on to the intermediate housing 16.Seal the remaining openings between the cutout and the hoses 1PH8 main motors 106 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Mechanical properties 3.6 Mounting of rotating unions on 1PH8 hollow-shaft motors 3.6.3 Mounting information and instructions Do not mount any additional anti-rotation pins on rotor-supported rotating unions Never screw pipes directly to the rotating union. Always use a hose between the rotating union and the fixed piping. To do this, route the hoses in curves and torsion-free. First screw the flexible hoses onto the rotor-supported rotating union. Then screw the rotating union onto the shaft with the specified torque. Avoid stressing due to incorrect hose lengths and unsuitable mounting material. The rotating union must be easy to turn when mounted. Keep rotating unions free of chips and burrs. Position the rotating union horizontally in such a way that the leakage connection is at the lowest point. Always route the leakage hose downward at at least 15 with a large cross-section. If the leakage hose is higher than the leakage connection and the mechanical seal is open, the rotating union and possibly also the motor will be flooded. The motor can fail. Also route the inlet hose downward. This causes the coolant to flow back in the supply line when the mechanical seal is open (e.g. tool change or standstill) and not through the motor shaft and the leakage connection. Filter the coolant so that no particles or chips can reach the mechanical seal and damage it. Note Mounting the rotating union * During assembly, screw the thread absolutely tightly into the NDE shaft extension. Ensure that no coolant can leak. Check the rotating union and hoses regularly for tightness. 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 107 Mechanical properties 3.6 Mounting of rotating unions on 1PH8 hollow-shaft motors Intermediate housing for air-cooled motors Cutout for hoses (to be made by the customer) Motor side Fan side 1PH8 main motors 108 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Mechanical properties 3.6 Mounting of rotating unions on 1PH8 hollow-shaft motors Slot dimensions for the intermediate housing 3.6.4 SH 80 SH100 SH132 SH160 A 155 196 260 314 B 99 133 183 225 C 6 6 7 7 R 16 16 19 19 D 170 185 175 180 Suggestion for an adapter for bearingless, frame-supported rotating unions Note Comply with the manufacturer's specifications Comply with the specifications and instructions provided by the manufacturer when installing the rotating union. Figure 3-12 Example of the version of an adapter for supporting the static part of a bearingless, frame-supported rotating union Diameter D1 1PH808. 1PH810.-1PH816. Diam. 22.5 H7 Diam. 30.5 H7 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 109 Mechanical properties 3.7 Radial and axial forces 3.7 Radial and axial forces 3.7.1 Radial force Specific radial forces may not be exceeded in order to guarantee perfect operation. For various shaft heights, a minimum force may not be fallen below. This minimum force is indicated in the radial force diagrams. The diagrams show the radial force FR at various operating speeds as a function of the bearing lifetime The force diagrams and tables apply to standard shaft ends at the DE. For smaller shaft diameters, only reduced radial forces may be transmitted or none at all. For force levels going beyond these, contact your local Siemens office. NOTICE Premature damage to bearings and shaft breakage due to strong radial forces Bearings can be prematurely damaged and shafts may break if force transmission elements apply too much load to the shaft end as a result of radial forces. * When using mechanical transmission elements, ensure that the maximum limit values specified in the radial force diagrams are not exceeded. NOTICE Premature damage to bearings due to insufficient radial forces Only for bearings with increased radial force (shaft height 100 to 280): Insufficiently high radial forces can cause the bearings to roll in an undefined fashion. This results in increased bearing wear. * For applications with an extremely low radial force load, ensure that the motor shaft is subject to at least the minimum radial force specified in the diagrams. Where the radial force load is less than the minimum radial force, e.g. on a coupling drive, you must not use the bearings for increased radial force. Use a motor with standard bearings for these applications. NOTICE Destruction of bearing seats The motor bearings are designed for operation with radial force. Rotating forces from the process or imbalance > Q 2.5 can destroy the bearing seats. Rotating forces and imbalance can also occur on coupling drives. * Avoid rotating forces and imbalance. 1PH8 main motors 110 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Mechanical properties 3.7 Radial and axial forces NOTICE Mechanical destruction of the motor If the motor supports the higher forces when force/torque boosting elements are used, the flange or the feet of the motor, for example, can be torn off. * Make sure that the force/torque boosting elements, e.g. gearbox or brakes, absorb the greater forces. Examples of remedies: - Choose the correct type of construction. - Pay attention to correct mechanical mounting of the force/torque boosting elements. Note Complying with the belt manufacturer's guidelines * When dimensioning the radial forces at the shaft extension, ensure that you comply with the regulations of the belt manufacturers. * Set the belt tension by means of appropriate measuring instruments. Calculating the total radial force FR for belt couplings If the belt manufacturer has not provided precise radial force data, the radial force can be determined approximately by the following formula: FR [N] = c FU Table 3- 22 FU [N] = 2 107 P / (n D) Explanation of the formula abbreviations Formula abbreviations Unit Description c -- Pre-tensioning factor: The pre-tensioning factor is an experience value provided by the belt manufacturer. It can be assumed as follows: For V belts: c = 1.5 to 2.5 for special plastic belts (flat belts), depending on the load type and belt type c = 2.0 to 2.5 FU N Circumferential force P kW Motor output n rpm Motor speed D mm Diameter of belt pulley 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 111 Mechanical properties 3.7 Radial and axial forces 3.7.2 Axial force The axial force acting on the locating bearings comprises the following components: - Axial force in operation Axial forces acting externally on the motor (e.g. gearbox with helical gearing, machining forces through the tool) Axial forces from the coolant pressure of the coolant fed through the rotating union - Force due to spring loading of the bearing - Where applicable, force exerted by the rotor weight when the motor is vertically mounted This results in a maximum axial force that is a function of the direction. CAUTION Axial force due to effective hydraulic diameter of the rotating union Pay attention to the axial force due to the effective hydraulic diameter (area) of the rotating union. Force = A x p * Force = F[N] * A = area [m] * p = coolant pressure [N/m] 1 bar = 105 N/m For axial forces in the direction of the motor, the spring-loading of the bearings can be overcome so that the rotor moves in accordance with the axial bearing play (up to 0.2mm). The permissible axial force FAZ in operation depends on the motor mounting position. When, for example, helical toothed wheels are used as the drive element, an axial force is exerted on the motor bearings in addition to the radial force. For axial forces in the direction of the motor, the spring-loading of the bearing can be overcome. This must be prevented as otherwise it could reduce the bearing and encoder service life. The permissible axial force FAZ in operation depends on the motor mounting position (see table "Calculating the permissible axial force"). 1PH8 main motors 112 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Mechanical properties 3.7 Radial and axial forces Table 3- 23 Calculating the permissible axial force Horizontal arrangement Shaft end facing downwards Shaft end facing upwards SH 80 - SH 160 with bearing version Standard with locating bearing, Performance, High Performance, Advanced Lifetime SH 80 - SH 160 with bearing version Standard SH 180 and SH 225 SH 280 FAZ Permissible axial force in operation FA Permissible axial force as a function of the average operating speed nm in each case, ignoring the preloading force and the force due to the weight of the rotor FC Pre-loading force FL Force due to weight of rotor 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 113 Mechanical properties 3.7 Radial and axial forces 3.7.3 Permissible radial and axial forces for 1PH808 Premium Performance For the Premium Performance version of the 1PH808, the following radial and axial forces of the motor shaft are permissible: Radial force = 100 N Axial force = 1400 N The axial force address comprises: Rotating union = 950 N Preloading Fc = 450 N Maximum permissible mechanical load DE shaft extension NDE shaft extension 100 N 100 N 1 Toward the motor 350 N - 2 Away from the motor 950 N - 1 Toward the motor 350 N 950 N 2 Away from the motor 950 N 350 N Maximum radial force Maximum radial force Solid shaft Hollow shaft 3.7.4 Radial and axial force diagrams Permissible radial forces for SH 80 Figure 3-13 SH 80, Standard, and Standard with locating bearing, 20000 h bearing lifetime 1PH8 main motors 114 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Mechanical properties 3.7 Radial and axial forces Figure 3-14 SH 80, Performance, High Performance, 12000 h bearing lifetime Figure 3-15 SH 80, Advanced Lifetime, 40000 h bearing lifetime Permissible radial forces for SH 100 Figure 3-16 SH 100, Standard, and Standard with locating bearing, 20,000 h bearing lifetime 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 115 Mechanical properties 3.7 Radial and axial forces Figure 3-17 SH 100, increased radial force, 20,000 h bearing lifetime, minimum radial force: 0.5 kN Note Bearing with increased radial force The roller bearings used here could sustain damage if they are operated under no load. Observe the specified minimum radial forces! Figure 3-18 SH 100, Performance, 12,000 h bearing lifetime 1PH8 main motors 116 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Mechanical properties 3.7 Radial and axial forces Figure 3-19 SH 100, High Performance, 12,000 h bearing lifetime Figure 3-20 SH 100, Advanced Lifetime, 40,000 h bearing lifetime Permissible radial forces for SH 132 Figure 3-21 SH 132, Standard, and Standard with locating bearing, 20,000 h bearing lifetime 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 117 Mechanical properties 3.7 Radial and axial forces Figure 3-22 SH 132, increased radial force, 20,000 h bearing lifetime, minimum radial force: 0.7 kN Note Bearing with increased radial force The roller bearings used here could sustain damage if they are operated under no load. Observe the specified minimum radial forces! Figure 3-23 SH 132, Performance, 12,000 h bearing lifetime 1PH8 main motors 118 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Mechanical properties 3.7 Radial and axial forces Figure 3-24 SH 132, High Performance, 12,000 h bearing lifetime Figure 3-25 SH 132, Advanced Lifetime, 40,000 h bearing lifetime Permissible radial forces for SH 160 Figure 3-26 SH 160, Standard, and Standard with locating bearing, 20,000 h bearing lifetime 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 119 Mechanical properties 3.7 Radial and axial forces Figure 3-27 SH 160, increased radial force, 16,000 h bearing lifetime, minimum radial force: 1 kN Note Bearing with increased radial force The roller bearings used here could sustain damage if they are operated under no load. Observe the specified minimum radial forces! Figure 3-28 SH 160, Performance, 12,000 h bearing lifetime 1PH8 main motors 120 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Mechanical properties 3.7 Radial and axial forces Figure 3-29 SH 160, High Performance, 12,000 h bearing lifetime Figure 3-30 SH 160, Advanced Lifetime, 40,000 h bearing lifetime Permissible radial forces for SH 180 Figure 3-31 SH 180, Standard with locating bearing, 20000 h bearing lifetime 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 121 Mechanical properties 3.7 Radial and axial forces Figure 3-32 SH 180, increased radial force, 12000 h bearing lifetime, minimum radial force: 4 kN Note Bearing with increased radial force The roller bearings used here could sustain damage if they are operated under no load. Observe the specified minimum radial forces! Figure 3-33 SH 180, Performance, 12,000 h bearing lifetime Permissible radial forces for SH 225 Figure 3-34 SH 225, Standard with locating bearing, 20,000 h bearing lifetime 1PH8 main motors 122 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Mechanical properties 3.7 Radial and axial forces Figure 3-35 SH 225, increased radial force, 12,000 h bearing lifetime, minimum radial force: 5 kN Note Bearing with increased radial force The roller bearings used here could sustain damage if they are operated under no load. Observe the specified minimum radial forces! Figure 3-36 SH 225, Performance, 12,000 h bearing lifetime 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 123 Mechanical properties 3.7 Radial and axial forces Permissible radial forces for SH 280 Figure 3-37 SH 280, Standard with locating bearing, 20000 h bearing lifetime Figure 3-38 SH 280, increased radial force, 12000 h bearing lifetime, minimum radial force: 9 kN Note Bearing with increased radial force The roller bearings used here could sustain damage if they are operated under no load. Observe the specified minimum radial forces! Axial forces Deep-groove ball bearings can absorb both radial as well as axial forces. The maximum axial forces FA as a function of the radial force are shown in the following force diagrams. 1PH8 main motors 124 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Mechanical properties 3.7 Radial and axial forces The permissible bearing forces are specified without taking into account the force due to spring-loaded bearings, the rotor weight for vertical mounting as well as the direction of the force. Note Determining the permissible axial forces The permissible axial forces at the shaft extension FA perm are dependent on the application (mounting, force direction) and must be calculated. Forces due to the rotor weight and spring-loading forces Table 3- 24 Force due to weight and spring-loading of the rotor Motor type Force due to weight FL Force due to spring-loading FC [N] [N] +/- 25% 1PH8081 65 450 1PH8083 90 1PH8087 115 1PH8101 120 1PH8103 150 1PH8105 195 1PH8107 220 1PH8131 270 1PH8133 330 1PH8135 390 1PH8137 445 550 900 1PH8138 1PH8163 600 1,200 1PH8164 1PH8165 715 1PH8166 1PH8167 655 1PH8168 1PH8184 900 1PH8184 (type of construction IM V5, V15) 1PH8186 1PH8186 (type of construction IM V5, V15) 880 2,300 1,150 880 2,300 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 125 Mechanical properties 3.7 Radial and axial forces Motor type Force due to weight FL Force due to spring-loading FC [N] [N] +/- 25% 1PH8224 1710 880 1PH8226 2,160 1PH8228 2,570 1PH8284 3,300 1PH8286 4,000 1PH8288 4,700 1,100 Permissible axial forces for shaft height 80 Figure 3-39 SH 80, Standard, and Standard with locating bearing, 20000 h bearing lifetime 1PH8 main motors 126 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Mechanical properties 3.7 Radial and axial forces Figure 3-40 SH 80, Performance, High Performance, 12000 h bearing lifetime Figure 3-41 SH 80, Advanced Lifetime, 40000 h bearing lifetime 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 127 Mechanical properties 3.7 Radial and axial forces Permissible axial forces for shaft height 100 Figure 3-42 Table 3- 25 SH 100, increased radial force, 20,000 h bearing lifetime Motor type 1PH810 SH 100, Standard, and Standard with locating bearing, 20,000 h bearing lifetime Max. permissible axial force as a function of speed Speed n (rpm) 1,500 2,000 3,000 4,000 5,000 6,000 7,000 Axial force FA (N) 2,100 2,050 1,950 1,850 1,750 1,700 1,650 Note The permissible axial force is absorbed exclusively by the deep-groove ball bearing of the duplex bearing. The cylindrical roller bearing absorbs the radial force. The axial force FAZ that is permissible during operation is calculated as stated in table "Calculating the permissible axial force (Page 112)." 1PH8 main motors 128 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Mechanical properties 3.7 Radial and axial forces Figure 3-43 SH 100, Performance, 12,000 h bearing lifetime Figure 3-44 SH 100, High Performance, 12,000 h bearing lifetime 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 129 Mechanical properties 3.7 Radial and axial forces Figure 3-45 SH 100, Advanced Lifetime, 40,000 h bearing lifetime Permissible axial forces for SH 132 Figure 3-46 SH 132, Standard, and Standard with locating bearing, 20,000 h bearing lifetime 1PH8 main motors 130 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Mechanical properties 3.7 Radial and axial forces Table 3- 26 SH 132, increased radial force, 20,000 h bearing lifetime Motor type 1PH813 Max. permissible axial force as a function of speed Speed n (rpm) 1,500 2,000 3,000 4,000 5,000 6,500 - Axial force FA (N) 2,600 2,550 2,400 2,250 2,200 2,100 - Note The permissible axial force is absorbed exclusively by the deep-groove ball bearing of the duplex bearing. The cylindrical roller bearing absorbs the radial force. The axial force FAZ that is permissible during operation is calculated as stated in table "Calculating the permissible axial force (Page 112)." Figure 3-47 SH 132, Performance, 12,000 h bearing lifetime 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 131 Mechanical properties 3.7 Radial and axial forces Figure 3-48 SH 132, High Performance, 12,000 h bearing lifetime Figure 3-49 SH 132, Advanced Lifetime, 40,000 h bearing lifetime 1PH8 main motors 132 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Mechanical properties 3.7 Radial and axial forces Permissible axial forces for SH 160 Figure 3-50 Table 3- 27 SH 160, increased radial force, 16,000 h bearing lifetime Motor type 1PH816 SH 160, Standard, and Standard with locating bearing, 20,000 h bearing lifetime Max. permissible axial force as a function of speed Speed n (rpm) 1,500 2,000 3,000 4,000 5,300 - - Axial force FA (N) 4,000 3,800 3,550 3,400 3,250 - - Note The permissible axial force is absorbed exclusively by the deep-groove ball bearing of the duplex bearing. The cylindrical roller bearing absorbs the radial force. The axial force FAZ that is permissible during operation is calculated as stated in table "Calculating the permissible axial force." 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 133 Mechanical properties 3.7 Radial and axial forces Figure 3-51 SH 160, Performance, 12,000 h bearing lifetime Figure 3-52 SH 160, High Performance, 12,000 h bearing lifetime 1PH8 main motors 134 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Mechanical properties 3.7 Radial and axial forces Figure 3-53 SH 160, Performance, 12,000 h bearing lifetime Figure 3-54 SH 160, Advanced Lifetime, 40,000 h bearing lifetime See also Axial force (Page 112) 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 135 Mechanical properties 3.7 Radial and axial forces Permissible axial forces for SH 180 Figure 3-55 SH 180, Standard/Performance, 20000/12000 h bearing lifetime Figure 3-56 SH 180, increased cantilever forces, 12000 h bearing lifetime 1PH8 main motors 136 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Mechanical properties 3.7 Radial and axial forces Permissible axial forces for SH 225 Figure 3-57 SH 225, Standard/Performance, 20000/12000 h bearing lifetime Figure 3-58 SH 225, increased cantilever forces, 12000 h bearing lifetime 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 137 Mechanical properties 3.7 Radial and axial forces Permissible axial forces for SH 280 Figure 3-59 SH 280, Standard, 20000 h bearing lifetime Figure 3-60 SH 280, increased cantilever forces, 12000 h bearing lifetime 1PH8 main motors 138 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Mechanical properties 3.8 Radial eccentricity, concentricity and axial eccentricity 3.8 Radial eccentricity, concentricity and axial eccentricity The shaft and flange accuracies are always checked in accordance with DIN 42955, IEC 60072. For shaft heights 180, 225 and 280, however, the flange accuracy is checked in accordance with DIN 50347. Data deviating from these values are indicated in the dimension drawings. Table 3- 28 Radial eccentricity tolerance of the shaft to the frame axis (in relation to the cylindrical shaft extensions) Shaft height Tolerance level N Tolerance level R Tolerance SPECIAL 80 0.05 0.025 0.01 100 0.05 0.025 0.01 132 0.05 0.025 0.01 160 0.06 0.03 0.01 180 0.06 0.03 - 225 0.06 0.03 - 280 0.07 0.035 - Figure 3-61 Checking the radial eccentricity Table 3- 29 Concentricity and axial eccentricity tolerance of the flange surface to the shaft axis (referred to the centering diameter of the mounting flange) Shaft height Tolerance level N Tolerance level R Tolerance SPECIAL 80 0.1 0.05 0.03 100 0.1 0.05 0.04 132 0.125 0.063 0.04 160 0.125 0.063 0.04 180 0.125 0.063 - 225 0.125 0.063 - 280 0.16 0.08 - 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 139 Mechanical properties 3.9 Balancing Figure 3-62 Checking the concentricity and axial eccentricity Note Acceptance test certificate The runout, concentricity and axial eccentricity are tested in the Siemens factories as standard. For 1PH8 motors, an acceptance test certificate with the values actual measured can be ordered with option B36. 3.9 Balancing 3.9.1 Requirements Requirements placed on the process when balancing mounted components - especially belt pulleys In addition to the balance quality of the motor, the vibration quality of motors with mounted belt pulleys and coupling is essentially determined by the balance quality of the mounted component. If the motor and mounted component are separately balanced before they are assembled, then the process used to balance the belt pulley or coupling must be adapted to the motor balancing type. 1PH8 main motors 140 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Mechanical properties 3.9 Balancing For asynchronous motors, a differentiation should be made between the following balancing types: Half-key balancing (an "H" is stamped on the shaft face) Full-key balancing (an "F" is stamped on the shaft face) Smooth shaft end (no keyway) The balancing type is coded in the order designation. Note Machining the feather key In the case of a half-key balanced shaft end and short output element, remove if necessary the part of the feather key which protrudes out of the output element and beyond the shaft contour. This is urgently recommended in the case of speeds above 1000 rpm and high requirements of balance quality. For the highest demands placed on the system balance quality, we recommend that motors with smooth shaft (without keyway) are used. For motors balanced with full key, we recommend belt pulleys with two keyways on opposite sides, however, with only one key in the shaft end. Table 3- 30 Requirements placed on the balancing process as a function of the motor balancing type Balancing equipment/ Motor Process step Half key balanced Auxiliary shaft to balance the mounted component Attaching the mounted component to the auxiliary shaft for balancing Motor balanced with full key Motor with plain shaft end * Auxiliary shaft with keyway * Auxiliary shaft with keyway * Auxiliary shaft without keyway * Keyway with the same dimensions as in the motor shaft end * * If required, use a tapered auxiliary shaft * Auxiliary shaft half key balanced Slot design with the exception of the slot width (as the motor) can be freely selected * Auxiliary shaft full key balanced * Balance quality of the auxiliary shaft 10 % of the required balance quality of the component to be mounted to the motor * Attached using a key * Attached using a key * Key design, dimensions and materials the same as at the motor shaft end * Key design, dimensions and material the same as used for the full key balancing of the auxiliary shaft * Attach the component as far as possible without any play, e.g. using a light press fit on the tapered shaft 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 141 Mechanical properties 3.9 Balancing Balancing equipment/ Motor Process step Half key balanced Motor balanced with full key Motor with plain shaft end Position the mounted component on the auxiliary shaft * Select a position between * the mounted component and the key of the auxiliary shaft so that it is the same when mounted on the actual motor Balance the mounted component * Two-plane balancing is recommended - i.e. balancing in two planes at both sides of the mounted components at right angles to the axis of rotation No special requirements Special requirements If special requirements are placed on the smooth running operation of the machine, we recommend that the motor together with the output components is completely balanced. In this case, balancing should be carried out in two planes of the output component. 3.9.2 Balancing 1PH8 motors with "Premium Performance" bearing version The on-site mechanical system vibration characteristics depend on factors such as the output elements, mounting situation, alignment, installation, and external vibration and can increase the level of motor vibration. Under certain circumstances, the rotor may have to be balanced completely with the output element. 1PH8 motors are supplied with "special" vibration severity. Mounting a coupling element on the shaft extension changes the rotor balancing state. As a consequence, after mounting coupling elements, the rotor must be completely balanced. The following description shows, using an example, the procedure for 1PH8 motors with "Premium Performance" bearing version. You must determine the vibration severity and the position of the imbalance by making the appropriate measurements. You can then remove the imbalance. Measuring unit required 2-channel vibration measuring unit Frequency bandwidth: 10 Hz to 1000 Hz The measuring unit must be equipped with a function to analyze orders of frequency components. Using this function, you can display the imbalance (1st order vibration component). 1PH8 main motors 142 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Mechanical properties 3.9 Balancing Typical approach 1. Prepare to make the reference measurement. Freely suspended the motor according to IEC 60034-14. The natural frequency of the motor-spring system must be less than 3 Hz. As a consequence, use springs that are adapted to the motor mass. The motor must be freely suspended so that the reference measurement can provide a correct measurement result. 2. Make a reference mark on the shaft (DE) for the speed and angle detection. 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 143 Mechanical properties 3.9 Balancing 3. Position the measuring sensors: Sensor 1 for the DE, sensor 2 for the NDE. 4. Perform the reference measurement on the freely suspended motor for the DE and the NDE. Measure the absolute value and angular position of the imbalance (1st order). 5. Attach the coupling to the shaft extension (DE). 1PH8 main motors 144 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Mechanical properties 3.9 Balancing 6. Perform the measurement on the coupled motor for the DE and the NDE. Also in this case, measure the absolute value and angular position of the imbalance (1st order). 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 145 Mechanical properties 3.9 Balancing 7. Remove the imbalance. To do this, screw one or several balancing screws into the rotor. Start at the side with the highest absolute imbalance. For instance, if you detect an imbalance at the DE at an angle of 175, then you must screw in a balancing screw on the opposite side at an angle of 355 (175 + 180 = 355). 8. It may be necessary to repeat Point 6 and Point 7 several times until the imbalance has been completely removed. 1PH8 main motors 146 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Mechanical properties 3.10 Vibration response 3.10 Vibration response 3.10.1 Mounting and mounting instructions In order to ensure smooth, vibration-free motor operation, a stable foundation design is required, the motor must be precisely aligned, and the components that are to be mounted on the shaft extension must be correctly balanced. The following mounting instructions must be carefully observed: For high-speed machines, we recommend that the complete unit is dynamically balanced after couplings or belt pulleys have been mounted. Use suitable equipment when mounting drive elements. Use the thread at the shaft extension. Do not apply any shocks or axial pressure to the shaft extension. Especially for high-speed motors with flange mounting, it is important that the mounting is stiff in order to locate any natural frequency as high as possible so that it remains above the maximum rotational frequency. Thin sheets (shims) can be placed under the motor mounting feet to align the motor and to avoid mechanically stressing the motor. The number of shims used should be kept to a minimum. In order to securely mount the motors and reliably and safely transfer the drive torque, bolts with strength class 8.8 according to ISO 898-1 should be used. Note Comply with permissible vibration values All flange-mounted motors must have a stable motor suspension assembly and for high field weakening speeds must be supported using the appropriate feet at the bearing end shield (foot/flange type of construction, also refer to Section "Vibration severity limit values"). Support using feet at the bearing end shield is not required if the following conditions are maintained: - For flange-mounted motors, there is a stable motor suspension design - The permissible vibration values according to DIN ISO 10816 are maintained - The maximum speed is limited (refer to Table "Restricting the maximum speed") Motors that are mounted, as a result of their type of construction, to the wall using the motor feet, must be fixed in place using an adequately dimensioned positive form fit (e.g. using studs or mounting rails). When commissioning the motors, it must be ensured that the permissible vibration values according to DIN ISO 10816 are maintained. 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 147 Mechanical properties 3.10 Vibration response Table 3- 31 Limiting the maximum speed Shaft height [mm] Max. permissible speed [rpm] 180 3,000 225 2,500 280 2,000 Table 3- 32 Flange mounting with threaded studs and nuts Shaft height M1 [mm] 180 32 225 45 280 45 Note Flange mounting SH 180 to SH 280 For SH 180 to SH 280, flange mounting is only possible using studs and nuts. Clearance M1 for threading the nut between the motor flange and motor frame according to DIN 42948. NOTICE Check the bearing If liquid accumulates at the flange because of vertical or horizontal mounting, the bearing and the bearing grease may be adversely affected. * Prevent liquid from collecting at the flange. Note Attaching plastic covers for SH 80 up to SH 160 * With the forced-ventilated versions of shaft heights 80 to 160, before the motor is commissioned you must replace the plastic covers that were removed so that the mounting bolts could be tightened. 1PH8 main motors 148 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Mechanical properties 3.10 Vibration response Figure 3-63 Cover for mounting foot Note Mounting air-cooled motors * Air-cooled motors must be mounted in such a way that the cooling air can enter and be discharged without any obstruction (see also Chapter "Cooling"). 3.10.2 Natural frequency when mounted The motor is a system which is capable of vibration at its natural frequency. For all motors, this natural frequency lies above the specified maximum speed. When the motor is mounted onto a machine, a new system, which is capable of vibration, is created with modified natural frequencies. These can lie within the motor speed range. This can result in undesirable vibrations in the mechanical drive transmission. Note Avoiding natural frequencies when mounting Motors must be carefully mounted on adequately stiff foundations or bedplates. Additional elasticities of the foundation/bedplates can result in resonance effects of the natural frequency at the operating speed and therefore result in inadmissibly high vibration values. The magnitude of the natural frequency when the motor is mounted depends on various factors and can be influenced by the following points: Mechanical transmission elements (gearboxes, belts, couplings, pinions, etc.) Stiffness of the machine design to which the motor is mounted Stiffness of the motor in the area around the foot or customer flange Motor weight 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 149 Mechanical properties 3.10 Vibration response Machine weight and the weight of the mechanical system in the vicinity of the motor Damping properties of the motor and the driven machine Mounting type, mounting position (IM B5, IM B3, IM B35, IM V1, etc.) Motor weight distribution, i.e. length, shaft height 3.10.3 Misalignment To avoid or minimize misalignment, a compensating coupling should be used (see the diagram). Figure 3-64 Mechanical output transmission shaft with its own bearings and compensating coupling If possible, the motor should not be directly and rigidly coupled to an output transmission shaft which has its own bearings. However, if a rigid coupling is absolutely necessary for mechanical design reasons, misalignment deviations must be avoided. In this case, a careful check must be made by making the appropriate measurements. Vertical and horizontal alignment The following measures are required to compensate for any radial offset at the coupling and to horizontally adjust the electric motor with respect to the driven load: Place shims under the motor feet to position it vertically and to prevent stress in the machine. The number of shims should be kept as low as possible, so use as few thicker shims as possible instead of several thinner shims. For horizontal positioning, push the motor sideways on the foundation Pay attention to maintaining the axial position. When positioning the motor, ensure that a uniform axial gap is maintained around the coupling. Note on alignment accuracy: Remember to take account of data concerning the alignment accuracy of the driven load and the coupling. 1PH8 main motors 150 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Mechanical properties 3.10 Vibration response Alignment accuracy 1. Align the motors with coupling output in such a manner that the center lines of the shafts are parallel with no offset. This ensures that no additional forces affect their bearings during operation. 2. Perform the fine adjustments with shims under the entire motor foot. Figure 3-65 Table 3- 33 Aligning the drive Permissible deviations when aligning the motor Permissible deviations Radial shaft offset [x] Axial shaft offset [y] Flexible coupling 0.05 mm 0.05 mm 3.10.4 Flywheels Flywheels with a high mass, which are rigidly mounted to the end of the motor shaft, modify the vibration characteristics of the motor and shift the critical rotational frequencies of the motor into the lower speed ranges. The overall system should be precision balanced in order to minimize/avoid exciting vibration, when external masses are directly mounted onto the motor shaft. Operation in the resonance range must be avoided. 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 151 Mechanical properties 3.10 Vibration response 3.10.5 Vibration stressing The on-site system vibration behavior depends on factors such as the output elements, mounting situation, alignment, installation, and external vibration and can increase the level of vibration on the motor. Under certain circumstances, the rotor may have to be completely balanced with the output element. To ensure problem-free operation and a long service life, the vibration values according to ISO 10816 must not be exceeded at the defined measuring points on the motor. Table 3- 34 Maximum permissible radial vibration values for SH 80 to 1601) Vibration frequency Vibration values < 6.3 Hz Vibration amplitude s 0.16 mm 6.3 ... 250 Hz Vibration velocity vrms 4.5 mm/s > 250 Hz Vibration acceleration a 10 m/s2 Table 3- 35 Maximum permissible radial vibration values for SH 180 to 2801) Vibration frequency Vibration values < 6.3 Hz Vibration amplitude s 0.25 mm 6.3 ... 63 Hz Vibration velocity vrms 7.1 mm/s > 63 Hz Vibration acceleration a 4.0 m/s2 Table 3- 36 Maximum permissible axial vibration values for SH 80 to 1601) Vibration velocity Vibration acceleration vrms = 4.5 mm/s apeak = 2.25 m/s2 1) Both values must be maintained simultaneously 1PH8 main motors 152 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Mechanical properties 3.10 Vibration response Figure 3-66 Maximum permissible vibration velocity including vibration amplitude and vibration acceleration for SH 80 to 160 Table 3- 37 Maximum permissible axial vibration values for SH 180 to 2801) Vibration velocity Vibration acceleration vrms = 7.1 mm/s apeak = 3.55 m/s2 1) Both values must be maintained simultaneously Figure 3-67 Maximum permissible vibration velocity including vibration amplitude and vibration acceleration for SH 180 to 280 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 153 Mechanical properties 3.10 Vibration response To measure the vibration velocity, the measuring equipment must fulfill the requirements of ISO 2954. The vibration acceleration must be measured as a peak value in the time range in a frequency band of 10 to 2000 Hz. If appreciable vibration excitation in excess of 2000 Hz (e.g. gear teeth meshing frequencies) can be expected, the measurement range must be adapted accordingly. This does not alter the maximum permissible values. Note Avoiding continuous operation at natural frequencies Uninterrupted duty in the natural frequencies of the installed/mounted system should be avoided, as this generally leads to the permissible vibration values being exceeded and the system being damaged. To reduce vibration, flanged-mounted motors can be supported at the NDE. Note Measuring vibration values according to the standard Vibration must be analyzed and measured (measuring points, etc.) according to standard ISO 10816-3. Note Increased resistance to vibration 1PH8 motors with shaft heights 180 and 225 and with the option L03 can be used in compliance with certain operating conditions for applications with increased resistance to vibration (see Chapter "Increased resistance to vibration (Page 182)"). Possible applications are, for example, applications such as servo presses. 1PH8 main motors 154 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Mechanical properties 3.11 Vibration severity grade 3.11 Vibration severity grade The 1PH8 motors conform to vibration severity level A in accordance with EN 60034-14 (IEC 600-34-14). The values indicated refer only to the motor. The system vibration response depends on the conditions at the installation location and can result in higher vibration values at the motor. Note Vibration severity limit values According to the vibration severity limit value diagrams below, the motors operate within the limit values stipulated for versions R, S, SR or SPECIAL over the specified speed range. Furthermore, within the rated speed range, they correspond to vibration severity grades A or B as defined by EN 60034-14 (IEC 600-34-14). The balance quality depending on the bearing is encoded in the Article No., see Chapter "Selection and ordering data." As a general rule, high radial force load capacity is not compatible with high speed and high vibration quality. The reason for this is that the different applications require different bearings. Figure 3-68 Vibration severity limit values for SH 80 to 132 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 155 Mechanical properties 3.11 Vibration severity grade Figure 3-69 Vibration severity limit values for SH 160 to 280 Note Acceptance test certificate Compliance with the limits, depending on the vibration severity grade ordered, is ensured in the Siemens factories as standard. For 1PH8 motors, an acceptance test certificate with the vibration velocities actually measured can be ordered with option B35. 1PH8 main motors 156 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Mechanical properties 3.12 Noise emission 3.12 Noise emission The noise emissions of the 1PH8 depend on the type of cooling and are therefore described in Chapter "Cooling." 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 157 Mechanical properties 3.12 Noise emission 1PH8 main motors 158 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 4 Motor components and options 4.1 Motor components 4.1.1 Thermal motor protection A KTY84-130 or Pt1000 temperature sensor is integrated in the stator winding to monitor the winding temperature. The exact type of temperature sensor is stated on the nameplate. Table 4- 1 Features and technical data Type KTY 84-130 Pt1000 Resistance when cold (20 C) Approx. 580 Approx. 1090 Resistance when hot (100 C) Approx. 1000 Approx. 1390 Via signal cable Via signal cable Prewarning < 150 C Alarm/trip at max. 170 C 5 C Prewarning < 150 C Alarm/trip at max. 170 C 5 C Connection Response temperature 1) 1) With SH80: Prewarning < 130 C; Alarm/trip at max. 150 C 5 C The resistance change is proportional to the winding temperature change. The temperature characteristic is taken into account in the closed-loop control. The prewarning signal from the evaluation circuit in the SINAMICS drive converter can be externally evaluated. High short-term overload conditions require additional protective measures as a result of the thermal coupling time of the temperature sensor. The conductors for the temperature sensor are routed in one cable together with the encoder conductors. NOTICE Destruction of the temperature sensor if the insulation resistance is tested improperly. If the test voltage is connected to only one temperature sensor terminal, the temperature sensor will be destroyed. * Short-circuit the ends of the temperature sensor cables before applying the test voltage. 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 159 Motor components and options 4.1 Motor components NOTICE Destruction of the motor for a thermally critical load There is no adequate protection during a thermally critical load, e.g. a high overload at motor standstill. * Take additional protective measures, e.g. an overcurrent relay. * The "thermal motor model i2t monitoring" function must be activated in the converter. Note Connector for temperature sensors The temperature sensor is connected to the signal connector together with the speed encoder signal. 1PH8 motors without an encoder can only be ordered as induction motors. For connecting the temperature sensors of these motors, an additional cable entry M16 x 1.5 is required. The spare temperature sensor (option A25 for shaft heights 80 to 160) and the chain of PTC thermistors for alarm/trip (option A12) are connected to a signal terminal block in the terminal box. The following diagram shows the resistance characteristic as a function of the temperature for KTY 84-130 and Pt1000 temperature sensors. Figure 4-1 Comparison of KTY 84-130 and Pt1000 temperature sensors 1PH8 main motors 160 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Motor components and options 4.1 Motor components 4.1.2 Encoder 4.1.2.1 Encoder overview The encoder is specified with the corresponding letter in the 9th position of the article number of the motor. Note Different encoder types for motors with or without DRIVE-CLiQ The letter code in the 9th position of the article number for the required encoder type is different for motors with and without DRIVE-CLiQ. Table 4- 2 Encoder types for motors without DRIVE-CLiQ Encoder type 9th position of the Article No. Without encoder A Absolute encoder EnDat 2048 S/R (AM2048S/R encoder) E Incremental encoder HTL 1024 S/R (encoder HTL 1024 S/R) H Incremental encoder HTL 2048 S/R (encoder HTL 2048 S/R) J Incremental encoder sin/cos 1 Vpp 2048 S/R with C and D tracks M (encoder IC 2048 S/R) Incremental encoder sin/cos 1 Vpp 512 S/R without C and D tracks T (encoder IN 512 S/R) Incremental encoder sin/cos 1 Vpp 256 S/R without C and D tracks C (encoder IN 256 S/R) Incremental encoder HTL 1024 S/R (encoder HTL1024S/R) with connection via additional terminal box W Incremental encoder HTL 2048 S/R (encoder HTL2048S/R) with connection via additional terminal box Y Table 4- 3 Encoder types for motors with DRIVE-CLiQ Encoder type 9th position of the Article No. Absolute encoder, 22-bit singleturn + 12-bit multiturn (encoder AM22DQ) F Incremental encoder, 22-bit, with commutation position (encoder IC22DQ) D Incremental encoder 20-bit without commutation position (encoder N20DQ) U Incremental encoder 19-bit without commutation position (encoder IN19DQ) S External encoder (only possible for shaft height 280 and forced ventilation) 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 161 Motor components and options 4.1 Motor components Encoder type 9th position of the Article No. Incremental encoder HTL 1024 S/R HOG 22 (Baumer-Hubner) G Mounting prepared (additional Z options must be considered) Incremental encoder HTL 1024 pulses/revolution POG 10 (BaumerHubner) K Mounting prepared (additional Z options must be considered) 4.1.2.2 Encoder connection for motors with a DRIVE-CLiQ interface WARNING Danger to life when using an incorrect encoder module The DRIVE-CLiQ encoder contains motor and encoder-specific data and an electronic type plate. If you use an incorrect DRIVE-CLiQ encoder, this can result in death, severe injury and severe material damage. * Only use the DRIVE-CLiQ encoder and the electronic type plate for the original motor. * Do not mount the DRIVE-CLiQ encoder onto other motors. * Do not replace a DRIVE-CLiQ encoder by a DRIVE-CLiQ encoder belonging to another motor. * Only appropriately trained Siemens service personnel should replace DRIVE-CLiQ encoders. NOTICE Electrostatic discharge Electronic modules contain components that can be destroyed by electrostatic discharge. These modules can be easily destroyed if they are not handled properly. * To protect your equipment against damage, follow the instructions given in the chapter ESD Guidelines. Motors with DRIVE-CLiQ interface have an internal Sensor Module. This Sensor Module includes an electronic rating plate. This simplifies commissioning for the SINAMICS S110 / S120 drive system, since all the motor parameters are set automatically. 4.1.2.3 Encoder connection for motors without DRIVE-CLiQ (12/17-pole) Motors without DRIVE-CLiQ are connected using the 12 or 17-pin flange socket by default. You can equip induction motors with an additional terminal box, see Incremental encoder HTL 1024 S/R or HTL 2048 S/R (Page 166) 1PH8 main motors 162 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Motor components and options 4.1 Motor components 4.1.2.4 Encoder assignment as a function of maximum permissible speeds The following tables show the possible assignments of encoders to the 1PH8 motor series as a function of maximum permissible speeds. Table 4- 4 Encoder types for motors without DRIVE-CLiQ Encoder type Without AM2048 an S/R encoder HTL1024 HTL1024 HTL2048 HTL2048 IC2048 S/R S/R S/R S/R S/R IN512 S/R IN256 S/R 9th data position A E H W J Y M T C Permissible nmax speeds (encoder) in rpm - 12,000 9,000 9,000 4600 4600 12,000 15,000 24,000 1PH808- 10,000 11 2) 2) 4) 4) - - 1PH808- 15,000 1L1 - - - - - 3) 1PH808- 20,000 1M1 - - - - - 3) 5) 1PH808- 24,000 1N1 - - - - - - - - 1PH808- 5,000 1Q1 4) 4) - - 1PH810- 9,000 11 4) 4) - - 1PH810- 12,000 1L1 - - - - 1PH810- 18,000 1M1 - - - - - 3) 5) 1PH810- 5,000 1Q1 4) 4) - - 1PH813- 8,000 11 4) 4) - - Motor version and bearing system nmax (motor) rpm 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 163 Motor components and options 4.1 Motor components Encoder type Without AM2048 an S/R encoder HTL1024 HTL1024 HTL2048 HTL2048 IC2048 S/R S/R S/R S/R S/R IN512 S/R IN256 S/R 9th data position A E H W J Y M T C Permissible nmax speeds (encoder) in rpm - 12,000 9,000 9,000 4600 4600 12,000 15,000 24,000 1PH813- 10,000 1L1 - - - - 1PH813- 15,000 1M1 - - - - - 3) 1PH813- 4,500 1Q1 - - 1PH813- 4,500 21 - - - - - - - 1PH816- 6,500 11 4) 4) - - 1PH816- 9,000 1L1 - - 1PH816- 10,000 1M1 - - - - - 1PH816- 4,000 1Q1 - - 1PH816- 4,000 21 - - - - - - - 1PH818- 5,000 11 4) 4) - - 1PH818- 7,500 1L1 - - - - 1PH818- 3,800 21 - - - - - - - Motor version and bearing system nmax (motor) rpm 1PH8 main motors 164 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Motor components and options 4.1 Motor components Encoder type Without AM2048 an S/R encoder HTL1024 HTL1024 HTL2048 HTL2048 IC2048 S/R S/R S/R S/R S/R IN512 S/R IN256 S/R 9th data position A E H W J Y M T C Permissible nmax speeds (encoder) in rpm - 12,000 9,000 9,000 4600 4600 12,000 15,000 24,000 1PH822- 4,500 11 - - 1PH822- 6,000 1L1 - - - - 1PH822- 3,500 21 - - - - - - - 1PH828- 3,300 11 - - Motor version and bearing system nmax (motor) rpm Assignment possible 2) Motor/encoder assignment limited to 9000 rpm 3) Motor/encoder assignment limited to 12,000 rpm 4) Motor/encoder assignment limited to 4600 rpm 5) Motor/encoder assignment limited to 15,000 rpm Table 4- 5 Encoder types for motors with DRIVE-CLiQ Encoder type AM22DQ 9th data position Permissible nmax speeds (encoder) in rpm Motor version and bearing system IC22DQ IN20DQ IN19DQ F D U S 12,000 12,000 15,000 24,000 - - - 3) 5) nmax (motor) rpm 1PH808-1-1 1PH808-1-L1 10,000 15,000 1PH808-1-M1 20,000 - 3) 1PH808-1-N1 24,000 - - - 1PH808-1-Q1 5,000 - - 1PH810-1-1 9,000 - - 1PH810-1-L1 12,000 - 3) 5) 1PH810-1-M1 18,000 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 165 Motor components and options 4.1 Motor components Encoder type AM22DQ IC22DQ IN20DQ IN19DQ F D U S 12,000 12,000 15,000 24,000 9th data position Permissible nmax speeds (encoder) in rpm Motor version and bearing system nmax (motor) rpm 1PH810-1-Q1 5,000 - - 1PH813-1-1 8,000 - - 1PH813-1-L1 10,000 1PH813-1-M1 15,000 - 3) 1PH813-1-Q1 4,500 - - 1PH813-2-1 4,500 - - 1PH816-1-1 6,500 - - 1PH816-1-L1 9,000 1PH816-1-M1 10,000 - 1PH816-1-Q1 4,000 - - 1PH816-2-1 4,000 - - 1PH818-1-1 5,000 - - 1PH818-1-L1 7,500 - - 1PH818-2-1 3,800 - - 1PH822-1-1 4,500 - - 1PH822-1-L1 6,000 - - 1PH822-2-1 3,500 - - 1PH828-1-1 3,300 - - Assignment possible 3) Motor/encoder assignment limited to 12,000 rpm 5) Motor/encoder assignment limited to 15,000 rpm 4.1.2.5 Incremental encoder HTL 1024 S/R or HTL 2048 S/R Function Speed actual value sensing Indirect incremental measuring system for the position control loop One zero pulse (reference mark) per revolution Table 4- 6 Properties and technical data Properties Incremental encoder HTL Coupling at the NDE * with SH 80 to 225: Integrated in the motor * with SH 280: Built on to the motor Operating voltage +10 ... +30 V Current consumption max. 150 mA 1PH8 main motors 166 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Motor components and options 4.1 Motor components Properties Incremental encoder HTL Incremental resolution (periods per revolution) 1024 S/R or 2048 S/R Incremental signals HTL Track A, track B, Zero pulse and inverted signals Angular error 1' Maximum permissible speeds * With 1024 S/R: 9000 rpm * With 2048 S/R: 4600 rpm Connection Table 4- 7 Connection assignment, 12-pin flange-mounted socket PIN No. Signal 1 B* 2 +1R1 3 R 4 R* 5 A 6 A* 7 CTRL TACH 8 B 9 not connected 10 M encoder 11 -1R2 12 P encoder When viewing the plug-in side (pins) Cables Mating connector: 6FX2003-0SU12 Table 4- 8 Pre-fabricated cable for SINAMICS: 6FX 002 - 2AH00 - 0 Length 5 MOTIONCONNECT500 Max. cable lengths: without transfer of inverted signals,150 m with transfer of inverted signals, 300 m 8 MOTIONCONNECT800 For other technical data and length code, refer to catalog, Chapter "MOTION-CONNECT connection system" 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 167 Motor components and options 4.1 Motor components 4.1.2.6 Incremental encoder HTL for operation on SINAMICS G Encoder connection with terminal block using an additional terminal box Induction motors can be equipped with an additional terminal box. This means that you can connect the following HTL incremental encoders for operation with a SINAMICS G via a terminal block: HTL1024 S/R and HTL2048 S/R The additional terminal box is shown in the following diagram. Figure 4-2 Encoder connection via additional terminal box The following signal assignment applies for connecting an HTL incremental encoder: Terminal Signal assignment 1 -1R2 2 +1R1 3 B* 4 R 5 R* 6 A 7 A* 8 CTRL 9 B 10 M encoder 11 P encoder 1PH8 main motors 168 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Motor components and options 4.1 Motor components Note Additionally supplied sensors Connect the following additional sensors in the terminal box according to Chapter "Terminal boxes": * Temperature sensor as a standby or * PTC thermistor circuit for warning and shutdown Note Temperature sensor The temperature sensor type is stated on the nameplate (see Chapter "Thermal motor protection (Page 159)") 4.1.2.7 Incremental encoders IC 2048 S/R, IN 512 S/R and IN 256 S/R Function Angular measuring system for the commutation Speed actual value sensing Indirect incremental measuring system for the position control loop One zero pulse (reference mark) per revolution Properties Incremental encoder sin/cos 1Vpp Coupling at the NDE * with SH 80 to 225: Integrated in the motor * with SH 280: Built on to the motor Operating voltage +5 V 5 % Current consumption max. 150 mA Incremental resolution (periods per revolution) * 2048 S/R * 512 S/R * 256 S/R Incremental signals 1 Vpp Angular error 40 '', for 256 S/R: 93 " Maximum permissible speeds * With 2048 S/R: 12000 rpm * With 512 S/R: 15000 rpm * With 256 S/R: 24000 rpm 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 169 Motor components and options 4.1 Motor components Figure 4-3 Signal sequence and assignment for a positive direction of rotation (clockwise direction of rotation when viewed from the drive end) 1PH8 main motors 170 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Motor components and options 4.1 Motor components Connection Table 4- 9 Connection assignment, 17-pin flange-mounted socket PIN No. Signal 1 A 2 A* 3 R 4 D* 5 C 6 C* 7 M encoder 8 +1R1 9 -1R2 10 P encoder 11 B 12 B* 13 R* 14 D 15 0 V sense 16 5 V sense 17 not connected When viewing the plug-in side (pins) Cables Mating connector: 6FX2003-0SU17 Table 4- 10 6FX Pre-fabricated cable for SINAMICS 002 - 2CA31 - 5 MOTIONCONNECT500 0 Length Max. cable length 100 m 8 MOTIONCONNECT800 For other technical data and length code, refer to catalog, Chapter "MOTION-CONNECT connection system" 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 171 Motor components and options 4.1 Motor components 4.1.2.8 Absolute encoder AM 2048 S/R Function Angular measuring system for the commutation Speed actual value sensing Indirect absolute measuring system for the position control loop Table 4- 11 Properties and technical data Properties Absolute encoder (EnDat) Coupling at the NDE * with SH 80 to 225: Integrated in the motor * with SH 280: Built on to the motor Operating voltage +5 V 5 % Current consumption max. 300 mA Incremental resolution (periods per revolution) 2048 S/R Absolute resolution (coded revolution) 4096 Incremental signals 1 Vpp Serial absolute position interface EnDat Angular error 40'' Maximum permissible speeds With 2048 S/R: 12000 rpm 1PH8 main motors 172 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Motor components and options 4.2 Options Connection Table 4- 12 Connection assignment, 17-pin flange-mounted socket PIN No. Signal 1 A 2 A* 3 data 4 not connected 5 clock 6 not connected 7 M encoder 8 +1R1 9 -1R2 10 P encoder 11 B 12 B* 13 data* 14 clock* 15 0 V sense 16 5 V sense 17 not connected When viewing the plug-in side (pins) Cables Mating connector: 6FX2003-0SU17 Table 4- 13 Pre-fabricated cable for SINAMICS 6FX 002 - 2EQ10 - 0 Length 5 MOTIONCONNECT500 Max. cable length 100 m 8 MOTIONCONNECT800 For other technical data and length code, refer to catalog, Chapter "MOTION-CONNECT connection system" 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 173 Motor components and options 4.2 Options 4.2 Options 4.2.1 Overview of options Chapter "Selection and ordering data" contains an overview of which options are available for which shaft heights. 4.2.2 Sealing air connection (option Q12) Cooling lubricants containing oil capable of creepage, which can also be corrosive, are mainly used for machine tools and transfer machines. For critical applications involving media with extremely high creepage rates, generally degree of protection against water (according to EN 60034-5/IEC 60034-5) alone is not sufficient. To address these particular applications, 1PH8 main motors can be ordered with sealing air connection by specifying option Q12. The sealing air connection can be implemented in conjunction with terminal boxes or power connectors. Note Improved protection against oils and media that can creep Sealing air does not increase the IP degree of protection against water. It does, however, improve protection against oils and media that can creep. Note This option is only permissible for motors without relubrication. Note Increase the pressure for "Premium Performance" bearing version For the "Premium Performance" bearing version, you must increase the supply pressure to min. 2.0 x 105 Pa up to max. 5 x 105 Pa. Conditioning: A Main drives without a shaft sealing ring Min. inlet temperature (C) Ambient temperature Max. inlet temperature (C) 40 Max. residual water content (g/m) 0.12 1PH8 main motors 174 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Motor components and options 4.2 Options Max. residual oil content (g/m) 0.01 Max. residual dust (mg/m) 0.1 Min. supply pressure (Pa) 2.0 x 105 Max. supply pressure (Pa) 3 x 105 Particle size for hollow shaft encoder (m) <8 Particle size for optical encoders (m) <3 Conditioning: B Main drives with a shaft sealing ring Min. inlet temperature (C) Ambient temperature Max. inlet temperature (C) 40 Max. residual water content (g/m) 0.12 Max. residual oil content (g/m) 0.01 Max. residual dust (mg/m) 0.1 Min. supply pressure (Pa) 0.05 x 105 Max. supply pressure (Pa) 0.1 x 105 Particle size for hollow shaft encoder (m) <8 Particle size for optical encoders (m) <3 Figure 4-4 Sealing air connection (option Q12) Necessary sealing air volume Volume (Nm/h) (Nm = standard cubic meter) Approx. 2.3 (at 2 bar) Note The volume data refers to the specified minimum supply pressure. For higher supply pressures, the flow rate increases corresponding to the motor flow resistance. 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 175 Motor components and options 4.2 Options 4.2.3 Protection against explosion (options M03 and M39) Overview The 1PH8 motors can be used in hazardous areas if certain operating conditions are met. Explosion protection zone Option Shaft heights 2 M03 SH 80 to SH 160 22 M39 SH 80 to SH 160 SH 180 and SH 225 This use as intended in an hazardous area Zone 2 or Zone 22 complies with directives 2014/34/EU and 1999/92/EC - as well as the series of IEC/EN 60079 standards. Design criteria for shaft heights 80 to 160 Descriptions (data position in Article No.) 1 2 3 4 1 P H 8 5 6 Shaft height 80 0 8 Shaft height 100 1 0 Shaft height 132 1 3 Shaft height 160 1 6 7 - 8 9 10 11 12 - 13 14 15 16 - Z Overall length (cannot be selected, determined by the choice of rated power) Induction version 1 Synchronous version (only shaft height 132 and 160) Encoder systems for motors without a DRIVE-CLiQ interface Without an encoder E Incremental encoder HTL 1024 S/R (encoder HTL1024S/R) 1) 3) H Incremental encoder HTL 2048 S/R (encoder HTL2048S/R) 1) 4) J Incremental encoder sin/cos 1 Vpp 2048 S/R with C and D tracks (encoder IC2048S/R) 2) M (380 V to 480 V 3 AC) Type of construction A Absolute encoder EnDat 2048 S/R (encoder AM2048S/R) 2) Winding version Rated speeds Cooling 2 1) 400 rpm, 500 rpm, 600 rpm B 1000 rpm, 1150 rpm, 1350 rpm D 1500 rpm, 1750 rpm, 2000 rpm F 2000 rpm, 2300 rpm, 2650 rpm G Forced ventilation NDE -> DE (degree of protection IP 55) 1 Water cooling (degree of protection IP 55) 2 IM B3 (IM V5, IM V6) 0 IM B5 (IM V1, IM V3) 2 1PH8 main motors 176 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Motor components and options 4.2 Options Descriptions (data position in Article No.) 1 2 IM B35 (IM V15, IM V35) 3 4 5 6 7 - 8 9 10 11 12 - 13 14 15 16 - Z 3 5) Shaft extension (DE) Balancing Smooth shaft (without keyway) --- 0 Fitted key Full-key 1 Fitted key Half-key 2 Bearings Vibration severi- Shaft and ty acc. to flange accuracy Siemens/EN 60034-14 Standard with R/A locating bearing R B Standard with S/A locating bearing R C Standard with location bearing1) SR/A R D Standard R/A R G Standard S/A R H Advanced Lifetime 6) S/A R Q Power connection Cable entry Signal connection Terminal box (top) right DE A Terminal box (top) left DE B Terminal box (top) NDE left C (looking onto DE) Version Version for potentially explosive atmospheres Zone 2 M 03 Version for potentially explosive atmospheres Zone 22 M 39 In the version for hazardous areas zone 2 and zone 22, the following options are not possible: Z A12, A25, G14, K80, L74, Q12, U60, U61, U62, U63, U65, U66, U67, U68, Y64, 1) Only possible if the 8th data position is "1" (induction version) 2) Limited to nmax = 12,000 rpm 3) Limited to nmax = 9000 rpm 4) Limited to nmax = 4600 rpm 5) Only possible for shaft height 100, 132, and 160. 6) Limited to nmax = 5,000 rpm, shaft height 132: nmax = 4500 rpm, shaft height 160: nmax = 4000 rpm 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 177 Motor components and options 4.2 Options The motors for these hazardous areas have been released for SINAMICS S120 or SINAMICS G120 converters/inverters (version with PM 240). The following basic conditions must be met when operating the motors with third-party converters/inverters: Converters/inverters with pulse width modulation (PWM) Pulse frequency of at least 4 kHz Converter/inverter output voltage according to the following table: Line connection voltage Line Module (line-side converter/inverter infeed type) 400 V 3 AC Smart Line Module (SLM) unregulated 380 V Active Line Module (ALM) regulated 425 V Smart Line Module (SLM) unregulated 460 V Active Line Module (ALM) regulated 500 V 480 V 3 AC Converter output voltage 1) Minimum output voltage required for motor operation in order to achieve data according to data sheet. 1) The rated powers for motors for use in hazardous zones are reduced both in S1 and S6 duty in relation to the non-explosion protected version (standard version). The deratings are taken into account in the rating plate data: Article No. Version Derating 1PH8xxx-1xx1x-xxx1-Z, M03, or M39 Induction, forced ventilation 10 % 1PH8xxx-1xx2x-xxx1-Z, M03, or M39 Induction, water cooling 20 % 1PH8xxx-2xx1x-xxx1-Z, M03, or M39 Synchronous, forced ventilation 20 % 1PH8xxx-2xx2x-xxx1-Z, M03, or M39 Synchronous, water cooling 20 % In a Zone 2 hazardous area (option M03), for the induction motor versions, the permissible maximum speed (nmax) must be reduced: Article No. Version Maximum speed nmax 1PH808x-1xxxx-xxx1-Z, M03 Induction 6100 rpm 1PH810x-1xxxx-xxx1-Z, M03 Induction 4350 rpm 1PH813x-1xxxx-xxx1-Z, M03 Induction 3000 rpm 1PH816x-1xxxx-xxx1-Z, M03 Induction 2250 rpm The motors with forced ventilation have newly developed external fans for use in hazardous areas. These are in conformance with the applicable directives and standards. The altered dimensions are provided in the dimension drawings (Tool CAD CREATOR). The supply values for the external fans are specified in the following table: Article No. Max. current consumption at 400 V 3 AC / 50 Hz (10 %) [A] 400 V 3 AC / 60 Hz (10 %) [A] 480 V 3 AC / 60 Hz (10 %) [A] 1PH808x-1xx1x-xxx1-Z, M03 or M39 0.09 0.07 0.09 1PH810x-1xx1x-xxx1-Z, M03 or M39 0.16 0.13 0.17 1PH8 main motors 178 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Motor components and options 4.2 Options 1PH813x-1xx1x-xxx1-Z, M03 or M39 1PH813x-2xx1x-xxx1-Z, M03, or M39 0.18 0.25 0.23 1PH816x-1xx1x-xxx1-Z, M03 or M39 1PH816x-2xx1x-xxx1-Z, M03 or M39 0.35 0.53 0.47 Note All of the external fans are equipped with three-phase motors. Operating conditions for shaft heights 80 to 160 The following operating conditions must be carefully taken into consideration when operating SIMOTICS M-1PH8 motors in Zone 2 or Zone 22 hazardous areas: Specific operating instructions for use in hazardous areas must be provided with the motors (see link and documentation in the Intranet/Internet). Motor versions for use in hazardous areas are not UL-approved. As a consequence, these motors do not bear the cUR marking. Zone 2 (option M03): - Marking: II 3 G Ex nA IIB T3 Gc -15 C Ta +40 C - Device group II, category 3G, temperature class T3 - Type of protection "nA" (non-sparking) - Use in ambient temperatures -15 C up to +40 C at installation altitudes up to 1000 m Zone 22 (option M39): - Marking: II 3D Ex tc IIIB T160 C Dc IP55 -15 C Ta +40 C - Device group II, category 3D - Protection afforded by the enclosure, tc - Maximum surface temperature 160 C (according to EN 60079-0: 2012 general requirements) - Use in ambient temperatures -15 C up to +40 C at installation altitudes up to 1000 m The temperature sensor embedded in the motor winding must be evaluated. The trip temperature of the temperature sensor must be set to 135 C. For overload conditions, the explosion-protected external fans must be safely shut down. PTC sensors are integrated as standard for overload protection, which must be evaluated according to EN 60079-14. Alternatively, a suitable motor circuit breaker can be used for overload protection. The explosion-protected, forced ventilated and water-cooled SIMOTICS M-1PH8 motors have degree of protection IP55. The anti-twist protection provided for the signal connector must be correctly installed. Cable glands certified for hazardous areas must be used when connecting the cables. Unused threads must be sealed using an Ex-certified screw plug. 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 179 Motor components and options 4.2 Options The connecting cables must have a temperature rating of at least 80 C. Plastic-insulated, flexible cables must have the same durability as heavy-duty, rubber-insulated cables. SIEMENS MOTION-CONNECT power and signal cables meet these requirements. The motors have a ground connection at the bearing shield/enclosure. The motors must be additionally grounded at this connection point. Belt drives are only permissible if buildup of a static charge is ruled out in the machinery. If possible, explosion-protected motors should not be repainted. However, where this is unavoidable, the following requirements must be met: - Limit the surface resistance of the paint used: Surface resistance 1 G for motors belonging to device group III - Breakdown voltage 4 kV for device group III Please contact the Siemens Service Center (see Chapter "Introduction (Page 5)") regarding correct paint system (type, thickness, etc.) Design criteria for shaft heights 180 to 225 The motors with option M39 can be selected with the following article number suffix. 1PH818x-1Ax1x-xxx1-Z, Z=M39 1PH818x-1Ex1x-xxx1-Z, Z=M39 1PH818x-1Hx1x-xxx1-Z, Z=M39 1PH818x-1Jx1x-xxx1-Z, Z=M39 1PH818x-1Mx1x-xxx1-Z, Z=M39 1PH822x-1Ax1x-xxx1-Z, Z=M39 1PH822x-1Ex1x-xxx1-Z, Z=M39 1PH822x-1Hx1x-xxx1-Z, Z=M39 1PH822x-1Jx1x-xxx1-Z, Z=M39 1PH822x-1Mx1x-xxx1-Z, Z=M39 The listed motors cannot be supplied with the Performance bearing (14th data position = "L"). The 1PH8 motors of shaft height 180 and 225 with the option M39 are implemented with insulated NDE bearings as standard. The supply values for the external fans are specified in the following table: Article No. Max. current consumption at 400 V 3 AC (10%); 400 V 3 AC (10%); 480 V 3 AC (+5% / -10%); 50 Hz 60 Hz 60 Hz [A] [A] [A] 1PH818- 0.6 0.65 0.6 1PH822- 1.6 1.3 1.5 1PH8 main motors 180 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Motor components and options 4.2 Options Note All of the external fans are equipped with three-phase motors. Operating conditions for shaft heights 180 and 225 The following operating conditions must be considered for motors operated in a Zone 22 hazardous area: Specific operating instructions for use in hazardous areas must be provided with the motors (see link and documentation in the Intranet/Internet). Zone 22 (option M39): - Marking: II 3D Ex tc IIIB T155 C Dc IP55 -15 C Ta +40 C - Device group II, category 3D - Protection afforded by the enclosure, tc - Maximum surface temperature 155 C (according to EN 60079-0: 2012 general requirements) - Use in ambient temperatures -15 C up to +40 C at installation altitudes up to 1000 m The temperature sensor embedded in the motor winding must be evaluated. For overload conditions, the explosion-protected external fans must be safely shut down. PTC sensors are integrated as standard for overload protection, which must be evaluated according to EN 60079-14. The anti-twist protection provided for the signal connector must be correctly installed. Cable glands certified for hazardous areas must be used when connecting the cables. Unused threads must be sealed using an Ex-certified screw plug. The connecting cables must have a temperature rating of at least 80 C. Plastic-insulated, flexible cables must have the same durability as heavy-duty, rubber-insulated cables. SIEMENS MOTION-CONNECT power and signal cables meet these requirements. The motors have a ground connection at the bearing shield/enclosure. The motors must be additionally grounded at this connection point. Belt drives are only permissible if buildup of a static charge is ruled out in the machinery. The motors must be kept free of dust deposits > 5 mm. The type of construction IM V5 is only permissible with a protective roof (protection from falling parts) If possible, explosion-protected motors should not be repainted. However, where this is unavoidable, the following requirements must be met: - Limit the surface resistance of the paint used: Surface resistance 1 G for motors belonging to device group III - Breakdown voltage 4 kV for device group III 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 181 Motor components and options 4.2 Options For the correct paint system, consult the Siemens Service Center (see Chapter "Introduction"). Note For further information, contact Technical Support or your Siemens branch. 4.2.4 Increased resistance to vibration (option L03) Overview 1PH8 motors with shaft heights 180 and 225 and with the option L03 can be used in compliance with certain operating conditions for applications with an increased vibration load. Possible applications are, for example, applications such as servo presses. Design criteria for shaft heights 180 and 225 In conjunction with the option L03, the following motors can be selected: 1PH818x-1Ax00-xxx1-Z, Z=L03 1PH818x-1Ax10-xxx1-Z, Z=L03 1PH818x-1Ex00-xxx1-Z, Z=L03 1PH818x-1Ex10-xxx1-Z, Z=L03 1PH818x-1Hx00-xxx1-Z, Z=L03 1PH818x-1Hx10-xxx1-Z, Z=L03 1PH818x-1Jx00-xxx1-Z, Z=L03 1PH818x-1Jx10-xxx1-Z, Z=L03 1PH818x-1Mx00-xxx1-Z, Z=L03 1PH818x-1Mx10-xxx1-Z, Z=L03 1PH818x-2Ex00-xxx1-Z, Z=L03 1PH818x-2Ex10-xxx1-Z, Z=L03 1PH818x-2Mx00-xxx1-Z, Z=L03 1PH818x-2Mx10-xxx1-Z, Z=L03 1PH822x-1Ax00-xxx1-Z, Z=L03 1PH822x-1Ax10-xxx1-Z, Z=L03 1PH822x-1Ex00-xxx1-Z, Z=L03 1PH822x-1Ex10-xxx1-Z, Z=L03 1PH822x-1Hx00-xxx1-Z, Z=L03 1PH8 main motors 182 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Motor components and options 4.2 Options 1PH822x-1Hx10-xxx1-Z, Z=L03 1PH822x-1Jx00-xxx1-Z, Z=L03 1PH822x-1Jx10-xxx1-Z, Z=L03 1PH822x-1Mx00-xxx1-Z, Z=L03 1PH822x-1Mx10-xxx1-Z, Z=L03 1PH822x-2Ex00-xxx1-Z, Z=L03 1PH822x-2Ex10-xxx1-Z, Z=L03 1PH822x-2Mx00-xxx1-Z, Z=L03 1PH822x-2Mx10-xxx1-Z, Z=L03 Operating conditions of shaft heights 180 and 225 The vibration load that is permissible by default for the 1PH8 main motors is described in Chapter "Vibration response." The maximum permissible vibration accelerations in conjunction with option L03 are given in the following table: Table 4- 14 Maximum permissible vibration accelerations Standard Option L03 Option L03 SH 180 and SH 225 SH 180 SH 225 Vertical 1.0 g 4.0 g 3.5 g Horizontal 1.0 g 3.5 g 3.2 g Axial 1.0 g 3.5 g 3.2 g The vibration acceleration rates (0 peak) in the frequency range from 0 Hz to 1 kHz at the bearings must not exceed the values stated in the table. The position of the measuring points is defined in ISO 10816-1. The 1PH8 motor must be pinned with a grooved pin according to ISO 8740 at the DE and NDE end. The motor should be standing on a metal base while you do so. For easier disassembly, no blind holes in the base must be used for the pinning (recommendation: through holes for pressing through the grooved pins). Grooved pins acc. to ISO 8740 Grooved pin diameter SH 180 SH 225 5 mm 6 mm Measures included Reinforced version of a DE bearing shield Fan unit (EC fan) with upgraded electronic components Screws locked with Loctite 270 Otherwise, the statements and regulations in this configuration manual apply. 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 183 Motor components and options 4.2 Options Note For further information, contact Technical Support or your Siemens branch. 4.2.5 Holding brake (option) 4.2.5.1 Properties Operation with holding brake on the SINAMICS S The SINAMICS S drive system has various types of brake control. A detailed description of the individual functions and corresponding parameter assignment information can be found in the following manuals: SINAMICS S120 Function Manual (6SL3097-4AB00-0AP1) Section 6.14 SINAMICS S120/S150 List Manual (6SL3097-4AP00-0AP3) Section 2.12 Information on the current carrying capacity for the brake outputs/adapters of the individual SINAMICS power units can be found in the corresponding manuals. Control of the brake via additional switching elements may be required. Make sure the parameter assignments for the brake data in the SINAMICS are correct. This is particularly important for the setting values: Maximum motor speed (reduced value for the "holding brake" option) Opening and closing times of the holding brake Moment of inertia of the holding brake The corresponding setting values are listed for the specific brakes in the "Technical data of the holding brake" table. Functional principle of the holding brake A brake can be mounted at the DE side of 1PH8 motors, shaft heights 80, 100, 132, 160, 180 and 225. These brakes are electromagnetic units for dry-running operation. An electromagnetic field is used to release the brake which is applied using spring force. They function according to the closed-circuit principle, i.e. the spring-operated brake is triggered when the current is interrupted and holds the drive. When power is applied to the brake, it is released and the drive is free to rotate. When the power fails or an Emergency Stop is issued, the drive is braked from its actual speed down to standstill. 1PH8 main motors 184 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Motor components and options 4.2 Options Connection of the brakes (must be provided by the customer) Alternating voltage 230 VAC, 50 ... 60 Hz Direct voltage 24 VDC up to shaft height 160 Ambient temperature The brake module is designed for an ambient temperature of -5 C to +40 C. At temperatures below -5 C and longer periods without power being applied to the brake, then it cannot be excluded that the friction disk freezes. In this case, special measures must be applied after first contacting the manufacturer. Note Restricted maximum motor speed for a motor equipped with brake ///start here The maximum speed of a motor with holding brake is limited to the maximum speed of the holding brake (see nmax, Br speed specified in the characteristic curves). Note Selection and ordering data The selection and ordering data is contained in the chapter of the same name. Note No UL approval for the holding brakes The holding brakes are not UL-approved. Motors with brake mounting therefore do not have the cUR marking! 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 185 Motor components and options 4.2 Options Technical data of the holding brakes Figure 4-5 Technical data of the mounted holding brake (DE) with emergency stop function Figure 4-6 Terminology (time) for holding operation Explanation of terminology in the table Holding torque [Nm]: on motors with shaft heights 100 ... 160, the holding torque can be continuously set in the specified value range using an adjusting ring. The dynamic braking torque is approximately 70% of the set holding torque. Speed nmax [rpm]: Maximum permissible speed. 1PH8 main motors 186 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Motor components and options 4.2 Options Perm. single switching energy WE [kJ]: Permissible operating energy during an emergency stop, WE = Jtotal. x n2/182.4 x 10-3 (J in kgm2, n in rpm) Lifetime switching energy Wmax [MJ]: Max. possible switching energy of the brake (for emergency stop) until the brake linings have to be replaced, Wmax = WE x z Number of emergency stops z: The specified number of emergency stops refers to the specified conditions. A conversion can be made for operation under different conditions: Number of emergency stops z = Wmax/WE Coil current [A]: Current to release the brake. Release time [ms]: Separating time until the brake releases (the specified values refer to the maximum braking torque and rated voltage). Engaging time [ms]: Connecting time until the brake engages according to the diagram "Terminology (time) for holding operation." (The values refer to the maximum braking torque and rated voltage.) Use for the intended purpose "Single-disk spring-operated brake control modules" are for mounting on induction or synchronous motors and intended for use in commercial or industrial systems. It is prohibited to use the brake in hazardous areas and zones. The integrated single-disk spring-operated brake (electromagnetically opening system) is designed as holding brake. Occasional Emergency Stop operations are possible. NOTICE Irreversible reduction of the braking effect The braking effect can be irreversibly reduced if you do not observe the permissible number of braking operations per hour and/or the maximum permissible operating energy per hour. Further, this can have a negative impact on the function of the holding brake. * When setting up machines and systems (when using the jog mode), observe the information provided in the Table "Technical data of holding brakes". * The holding brake can be equipped with a manual release to remove the holding torque. 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 187 Motor components and options 4.2 Options NOTICE Inadvertent operation of the holding brake Material damage can occur if you inadvertently apply or release the holding brake. * Secure the holding brake against inadvertent operation and misuse. The mechanical manual brake release must always be in the center position when not operated (see the diagram "Spring-applied single-disk brake module"). Only then is the brake completely engaged, and it is ensured that the spring-applied single-disk brake module can provide its full braking effect. * You can remove the manual release lever. Observe the application-specific regulations on whether manual release is permissible, e.g. in manufacturing lifting equipment. * For the rated operating conditions, see DIN VDE 0580: 1994-10. For the degree of protection see DIN VDE 0470, part 1. Coordinate possible special measures with the manufacturer if deviations are found. WARNING Danger to life if the holding brake is used incorrectly If you use the holding brake incorrectly, e.g. you use it as safety brake, this can result in severe accidents with personal injury and/or material damage. * Observe the accident prevention regulations applicable to the specific application. Note Special measures If you find references to special measures and/or it is necessary to consult the manufacturer, already obtain the manufacturer's advice when you configure the system. 4.2.5.2 Mounted holding brake for SH 80 to SH 160 Properties The holding brakes for motors, shaft heights 80, 100, 132 and 160 are brake modules (manufactured by Kendrion Binder Magnete) with their own bearings, flange and shaft extension. The dimensions of the flange and shaft extension of the brake module are identical with those of the motor. If a motor is to be equipped with a brake, then a motor version with a flange-type of construction and a smooth shaft (without keyway and key) is used. The shaft of the brake module can then be shrunk onto the motor shaft (thermal technique). It can be released using pressurized oil. The brake module is bolted to the motor flange. Note Radial and axial forces The specifications for the "standard" bearing version apply for the permissible radial and axial forces. 1PH8 main motors 188 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Motor components and options 4.2 Options See also Radial and axial force diagrams (Page 114) Method of operation The brake module is an electromagnetic component with integrated electromagnetically opening single-disk spring-operated brake for dry running, in which the braking effect is applied by the spring force and canceled electromagnetically. If required, the braking effect can also be canceled by an additional mounted manual release. The brake module is a mounted brake, preferably on the DE end shield of electric motors, as built-on unit with bearing supported driver pin shaft. Structure The solenoid housing with the cast excitation winding is used to accommodate the armature , the friction disk and the flange that is attached using cylinder head screws. The compression springs in the solenoid housing that are supported via the thrust studs (size 13) on the adjustment ring , apply a force to the friction disk via the anchor in the axial direction and thus clamp the friction disk between the rigidly mounted flange and the anchor and produce the braking effect (torque). The tangent torque support of the armature against the solenoid housing is performed by the dowel pins. When a direct voltage is applied to the excitation winding, the resulting electromagnetic force pulls the armature against the force of the compression springs, the friction disk is released and thus the braking effect canceled. As the brake module represents a self-contained system, no forces are applied externally. The braking effect of the axial moving friction disk is transmitted to the driver pin shaft fixed to the motor shaft via the keyed connection of the internal square socket (sizes 13, 19 and 24) and/or via internal gearing (size 29). The ball bearing located between the solenoid housing and the driver pin shaft is used to center the brake to the driver pin shaft and therefore to the motor shaft when mounting the brake on the motor flange and also to absorb the transverse forces acting radially on the driver pin shaft. The ball bearing comes sealed from the factory. As additional protection against pollution and to prevent grease from a defective ball bearing seal reaching the friction disk, a sealing ring is mounted that prevents dirt, grease or oil reaching the area of the friction disk from the outside and abraded particles due to the wear of the friction disk escaping. The sealing ring provides the drive-side sealing between the flange and the driver pin shaft. The single-disk spring-operated brake module can be opened mechanically by hand, e.g. in the event of a power failure, via the optional manual release . The electrical connection is made directly in the terminal box . The transmissible torque of the brake module can be set via the adjustment ring. 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 189 Motor components and options 4.2 Options Manual brake release, optional Armature Friction disk Flange Winding Housing Shaft Adjustment ring (not for 1PH808) Terminal box Figure 4-7 Single-disk spring-operated brake module 77 500...B15 1PH8 main motors 190 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Motor components and options 4.2 Options Oval head screw (2x) Bellows Cylinder head screw (2x) Bolt Figure 4-8 Bracket Dowel pin Hexagon bolt M2.5x8 (not included in the scope of delivery) Microswitch Microswitch mounting of a single-disk spring-operated brake module 77 500...B15 Electrical connection WARNING Fire hazard and risk of destroying the brake module The brake module is an electromagnetic component and a DC system. An impermissibly high connection voltage at the brake module can cause the rectifier or the winding to burn. This can block the brake module, causing it to overheat. If the connection voltage is too low, the magnetic excitation will also be too low, preventing the brake from being released. The brake goes into the brake mechanism although this is not wanted. * Make sure that the connection voltage of the brake module remains within the permissible tolerance of +10 % to -10 % of the nominal voltage. Comply with the legal standards for connection to the grid. Pay attention to the correct dimensioning of the cable lengths and conductor cross-sections in the connection cables. Check the electrical connection of the holding brake based on the following checklist. 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 191 Motor components and options 4.2 Options Table 4- 15 Checklist for checking the electrical connection of the holding brake Check OK The connection cables are suitable for the type of use and the voltages and currents that occur. The connection cables are connected correctly by means of screws, clamps or other equivalent means, so that the electrical connection is maintained permanently. Adequately dimensioned connecting cables, torsion, strain and shear relief as well as anti-kink protection are provided for the connection cables. The protective conductor (only for protection class I) is connected at the grounding point. There is no foreign matter, dirt or moisture in the terminal box. Unused cable entries and the terminal box itself are sealed so that the specified degree of protection according to EN 60529 is maintained. Terminal box 5.1 Cover 5.2 Connecting terminal or rectifier 5.3 Fixing screw for cover Figure 4-9 Holding brake terminal box optionally with terminal or rectifier Connect the spring-applied single-disk brake module to the direct voltage. Use a rectifier bridge or half-wave rectifier for electrical connection to an AC power system. For brakes with integrated rectifiers, you can connect the spring-applied single-disk brake module directly to alternating voltage. See the figure for the terminal assignment. For brakes with a connecting terminal, you must connect the brake module directly to direct voltage. Connect the customer-specific connection cable to the terminals or to the integrated rectifier. Use a screwed cable gland (M16 x 1.5) for the connection. You must remove the cover of the terminal box to connect the individual stranded wires of the connecting cable to the connecting terminals or to the terminals of the integrated rectifier. 1PH8 main motors 192 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Motor components and options 4.2 Options Table 4- 16 Rectifier for operation on single-phase AC with electrical connection via connection terminal (5.2) Type Method Rated input voltage range U1 AC (40 ... 60 Hz) 32 07332B40 Halfwave Output voltage Max. output current U2 DC I DC [V] [V] R-load [A] L-load [A] 0 ... 500 (10 %) U1 * 0.445 1.6 2.0 Brakes with integrated rectifiers are either equipped with a half-wave rectifier or with a rectifier bridge. By appropriately connecting the integrated rectifier, you switch between AC (normal interlocking time t1) or DC (short interlocking time t1). Figure 4-10 Pin assignment of the rectifier Voltage ripples caused by switched-mode power supplies can cause humming or unintended behavior of the component depending on the size and torque. The user or the system manufacturer has to ensure proper operation by means of the electrical control. 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 193 Motor components and options 4.2 Options DC connection The basic curve of the voltage when the excitation winding (coil) (1.2) is switched off is as follows. UB Operating voltage (coil voltage) U Transient voltage Figure 4-11 Basic curve of the voltage when turning off the excitation winding NOTICE Overvoltages when switching off The voltage peak UVmax when switching off can reach several 1000 V in the millisecond range without a protective circuit. The excitation winding (coil) (1.2), switching contacts and electronic components can be destroyed. Sparks form at the switch on switch-off. * When it is switched off, the current must therefore be reduced via a snubber circuit. This also limits the voltages. The maximum permissible overvoltage when switching off must not exceed 1500 V. 1PH8 main motors 194 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Motor components and options 4.2 Options If Kendrion Binder rectifiers are used, the protective circuit for the internal electronic components and for the excitation winding (coil) (1.2) is integrated. This does not apply for the external contacts required for the DC-side switching because the galvanic isolation of the external contact is then no longer achieved. NOTICE Component damage resulting from a lower voltage Sensitive electronic components (e.g. logic components) and mechanical contact elements can also be damaged by the lower voltage. * Make sure that the voltage does not fall below the specified value, e.g. due to insufficient conductor cross-sections. AC connection NOTICE Impermissible overvoltages If you operate the brake module without a snubber circuit in a circuit on the DC side, impermissible overvoltages can arise. * Use a snubber circuit. * Avoid damage, e.g. due to contact erosion or contact welding of the external contact elements by taking additional protection measures, e.g. varistors or spark suppression elements. Direct connection to an AC voltage is only possible via a rectifier. Depending on the connection method (DC or AC operation), different interlocking times can be achieved. Half-wave rectification With half-wave rectification, the coil voltage U2 is less than the input voltage on the rectifier by a factor of 0.445. Half-wave rectifiers have a high residual ripple which have somewhat shorter switching times compared to the bridge rectification, depending on the module size. The half-wave rectifier is therefore preferable (also because of the smaller coil voltages). However, humming can occur in brake modules of small size. DC operation With DC-side circuitry of the brake module, an additional auxiliary contact is plugged into the motor contactor, which interrupts the current supply to the brake module on the DC side. 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 195 Motor components and options 4.2 Options Electrical connection of brake modules with microswitches Note Use of microswitches * Observe the special regulations regarding the permissible use of microswitches, e.g. for lifting gear and crane construction. WARNING Accidental motor starting In an unsecured motor circuit, the motor can start accidentally when the microswitch is closed. This can result in injury and/or material damage. * Secure the motor circuit accordingly. In brake modules with microswitches, the microswitch monitors the operating state of the spring-applied single-disk brake module. The brake module is either open or closed. For example, integrate the microswitch into the control circuit for controlling the machine or the motor. The microswitch prevents the machine or motor from starting against a closed brake module if it is integrated correctly. When ordering, the microswitch is available as an option. It is not possible to subsequently mount a microswitch. When the brake module is supplied, the microswitch is adjusted in the factory. Manual opening of the brake module WARNING Accidental drive acceleration after manually operating the brake control module If you manually open the spring-applied single-disk brake module, the load torque will accelerate an unbalanced drive. This can result in injury and/or material damage. * Take special care when inching the brake module open or closed. Make sure that no danger is posed by the load torque. Examples of situations in which manual operation of the brake module is necessary include Maintenance on the machine or the motor Failure of the regular power supply during UPS operation The spring-applied single-disk brake module can be manually opened via an externally mounted mechanical manual brake release (accessory). 1PH8 main motors 196 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Motor components and options 4.2 Options If you use a commercially available UPS power supply, e.g. a UPS battery system, the brake module can be opened electrically during a failure of the regular power supply. Observe the voltage stated on the nameplate of the brake module when installing a UPS power supply. Setting of the transmissible torque M4 Note Torque M4 The transmissible torque must not fall below the minimum value M4 when you adjust the adjustment ring according to table "Change of the transmissible torque." Always mark the modified adjustment ring distance E in the base of the solenoid housing pocket using a punch prick. Mark the theoretically set transmissible torque M4 on the nameplate of the motor. The empty field "Optional customer information" on the nameplate is available for this. After you have set the transmissible torque M4, make sure that you secure the adjustment ring with a threaded pin. Comply with the tightening torque of MA = 3 Nm. Turn the adjustment ring in such a way that the threaded pin can be located between the thrust studs. Deviations of the transmissible torque M4 from -5% to +15% are possible. The brake module is delivered with the transmissible torque M4 set to the default value according to the data sheet. You will find the transmissible torque M4 on the nameplate of the brake module. Table 4- 17 Change of the transmissible torque M4 [%] for an axial travel path of the adjustment ring by 1 mm; transmissible torque (default value) M4 Size 19 Size 24 Size 29 Change of the transmissible torque M4/mm [%] Approx. 15 Approx. 12 Approx. 14 Transmissible torque (default value) M4 [Nm] 150 310 500 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 197 Motor components and options 4.2 Options 4.2.5.3 Mounted holding brake for SH 180 and SH 225 Properties For these motors, the brake (manufactured by Stromag) is mounted on the DE end shield. In this case, the motor shaft is extended using a shrunk-on stub shaft. The torque is transmitted through a key according to DIN 6885/1. The stub shaft can in addition be axially secured using a spring washer and a central screw (M20). The holding brake does not have its own bearings. The output forces are therefore absorbed by the motor bearings. Belt pulleys cannot be mounted due to space reasons and also due to the high associated cantilever forces. When selecting the coupling to couple to the motor - brake combination - it should be carefully noted that the shaft extension diameter is larger than the diameter of the motor shaft extension. REVOLEX bolt-type couplings 2LF6337 for shaft height 180 and 2LF6338 for shaft height 225 should be preferably used. Ordering data and dimensions, refer to catalog M 11 or D 81.1. Note Radial and axial forces The specifications for the "standard" bearing version apply for the permissible radial and axial forces. See also Radial and axial forces (Page 110) 1PH8 main motors 198 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Motor components and options 4.2 Options Design, method of operation and construction features 1 Coil form with coil 40 Screw for tacho flange 2 Friction disk with friction lining 41 Fixing screw 3 Terminal box, complete 42 Cylinder head screw 4 Manual brake release, complete 46 Fixing screw for manual release cover 10 Armature disk 47 Screw for sliding block 11 Brake flange 49 Emergency release screw 12 Tacho flange 50 Screw plug for emergency release 13 Socket 52 Screw for blockable manual release 14 Adjustment ring 60 O-ring for tacho 15 Pinion 61 O-ring for brake flange 20 Shim 63 Lock nut for microswitch 21 Compression springs 64 Grub screw (microswitch) 22 Sliding block 65 Screw plug for air gap measurement 23 Spacer for terminal box 67 Screw connection 24 Spring bolt 73 Rating plate 25 Manual release cover 74 Pin (rating plate mounting) 26 Eccentric bolt 76 Adhesive 27 Deep-groove ball bearing 78 Washer for item 52 28 Microswitch 81 Sealing ring for item 50 Figure 4-12 Mounting of holding brake SH 180 and SH 225 The NFF brake is a spring-loaded electromagnetic twin-disk brake that brakes in the deenergized state and releases electromagnetically. 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 199 Motor components and options 4.2 Options The NFF brake type satisfies the highest requirements for fatigue strength, robustness and resistance to sea water. The brakes are constructed and tested in compliance with DIN VDE 0580. The brake is attached to a motor or another machine part using cylinder head screws (fixing screws, item 41). The bobbin contains a coil that is permanently encapsulated in synthetic resin of thermal class 155 (F, max. temperature limit 155 C). When the coil is de-energized, the compression springs (21) press the armature disk (10) axially against the friction disk with friction lining (2). This is clamped between the armature disk (10) and the brake flange (11) and thus prevented from rotating. The braking effect is transmitted to the shaft from the friction disk with friction lining (2) via the pinion (15) and a feather key. If the coil is connected to a rated DC voltage according to the specifications on the rating plate (73), the armature disk (10) is pulled against the spring pressure to the coil form (1) through the electromagnetic force. The friction disk with friction lining (2) is therefore freed and the braking effect is canceled. The brake is released. Mechanical release using the manual release bar By pulling the manual release bar (4) through approx. 30 against the rear side of the brake, the armature disk (10) is pulled axially against the coil form (1) and the friction disk with friction lining (2) is then free. WARNING Incorrect use of the emergency release If you use the emergency release to maintain operation temporarily, you may damage the brake. This can result in personal injury and damage to property. * Only ever use the emergency release in an emergency. Power supply line and electrical connection of the brake The electrical connection must be made in compliance with the installation regulations (e.g. DIN 92). The power connection provided by the customer is 230 V AC +/- 10%. The coil is dimensioned for the DC voltage specified on the rating plate (residual ripple < 0.5) and 100% cyclic duration. The continuously permissible voltage change is +6% to -10% of the rated voltage. To protect the coil or the power supply, a varistor of the appropriate operating voltage range and the required power should be connected to the coil input. 1PH8 main motors 200 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Motor components and options 4.2 Options Figure 4-13 Circuit configurations Figure 4-14 Circuit configurations Version with microswitch If monitoring of the switching state is required for a brake, a microswitch (28) can be used. If the armature disk (10) is moved against the coil form (1) through the electromagnetic force of the coil or through the mechanical emergency release, it actuates the microswitch (28) via the grub screw (64). The microswitch (28) can be integrated as an NC or NO contact in an electrical control or monitoring circuit. 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 201 Motor components and options 4.2 Options 4.2.6 Anti-condensation heating (option K45) Larger motors are prone to more frequent condensation on the winding caused by the climatic conditions because of the larger surfaces. Condensation can occur, for example, on non-rotating motors in a humid environment or on motors that are exposed to severe temperature fluctuations. Anti-condensation heaters heat the air in the motor by a few Kelvin above the ambient temperature and thus prevent precipitation inside the motor. On the 1PH8 motors, an anti-condensation heater can be ordered with option K45 for shaft heights 180, 225, and 280. Option K45 comprises a strip heater mounted on the winding overhang with a heating power of 100 W for a supply voltage of 230 V AC (50/60 Hz). The two terminals are routed into the main terminal box of the motor and can be connected via the auxiliary terminal strip. The terminals are identified as "1HE1" and "1HE2." Note: For shaft heights 180, 225, 280, the same strip heater is used. The anti-condensation heating must not be switched on while the motor is running. The anti-condensation heaters for 1PH8 motors are UL-approved. In addition to the anti-condensation heating, motors with degree of protection IP55 should also have condensation drain holes (see Chapter "Condensation drain hole (option L12)"). 4.2.7 Condensation drain hole (option L12) In larger motors, there is a risk of condensation or accumulation of condensed water inside the motor due to the climatic conditions. Condensation drain holes prevent the accumulation of a damaging quantity of water in the motor and are often used as the primary measure against condensed water as they are easy to implement in the design. In 1PH8 motors, the condensation drain holes are located at the lowest point in the NDE and DE bearing shields and are therefore only suitable for horizontal installation (type of construction IM B3, IM B5, and IM B35). The condensation drain holes for shaft height 180 and 225 are provided with a special insert (drainage plug); this insert is not required for shaft height 280. 1PH8 main motors 202 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Motor components and options 4.2 Options Water drainage hole Figure 4-15 1PH8 motor with condensation drain holes Table 4- 18 1PH8 motors that can be equipped with condensation drain holes Article No. Cooling Degree of protection Required option Comment 1PH818x-xxx0 1PH818x-xxx1 Forced ventilation IP 55 L12 Bearing shield NDE and DE Water cooling IP 55 - NDE and DE bearing shield (condensation drain hole always included as standard) 1PH822x-xxx0 1PH822x-xxx1 1PH828x-xxx1 1PH818x-xxx2 1PH822x-xxx2 1PH828x-xxx2 Note: Condensation drain holes are only used in motors with degree of protection IP 55. In motors with degree of protection IP 23 (open-circuit ventilation), the open design does not require condensation drain holes. (A harmful quantity of condensed water cannot accumulate.) Anti-condensation heating (see Chapter "Anti-condensation heaters") can be used in addition to the condensed water holes for a greater anti-condensation effect. 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 203 Motor components and options 4.2 Options 4.2.8 Extra grounding terminals in terminal box (Q00) For option Q00 (higher number of ground terminals in the terminal box), symmetrical power cables with a grounding conductor split into 3 can be connected more easily in the terminal box for large transmission powers. The grounding bar in the terminal box has a larger number of terminals in option Q00. Table 4- 19 Definition of Q00 according to the type of terminal box: Shaft height SH Terminal box type Number of terminals (grounding) standard Number of terminals (grounding) option Q00 280 1XB7712-P.. 4 x M16 12 x M6 Option Q00 has no influence on the dimension drawings, 3D drawings, and electrical configuration. For this reason, this option has not been included in CAD Creator or in SIZER. Figure 4-16 Grounding bar with option Q00 1PH8 main motors 204 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Motor components and options 4.2 Options 4.2.9 Three-phase external fan (option L75) Technical data and connection The external fan has a terminal box that is mounted on the external fan motor. Air flow direction 3 AC 400 V 3 AC 400 V 3 AC 480 V Sound pressure level LpA Air flow / 50 Hz / 60 Hz (1) / 60 Hz (1) (1 m) rate at 50 Hz, ap( 10 %) ( 10 %) (+5 %, Motor + external fan unit prox. 10 %) 50 Hz operation Tolerance + 3 dB Rated pulse frequency 2 kHz [A] [A] [A] [dB] [m3/s] 2.4 2.4 2.3 76 (2) 0.17 2.4 2.4 2.3 76 (2) 0.31 2.4 2.4 2.3 76 (3) 0.21 2.4 2.4 2.3 76 (3) 0.33 1PH8 forced ventilation, degree of protection IP55, L75 1PH818.-...0.-...1-Z DE NDE 1PH818.-...1.-...1-Z NDE DE 1PH822.-...0.-...1-Z DE NDE 1PH822.-...1.-...1-Z NDE DE 1PH8 open-circuit ventilation, degree of protection IP23, L75 1PH818.-...3.-...1-Z DE NDE 1PH818.-...4.-...1-Z NDE DE 1PH822.-...3.-...1-Z DE NDE 1PH822.-...4.-...1-Z NDE DE (1) 60 Hz operation only permissible with throttle plate (2) Speed ranges: 1PH818. up to 5000 rpm, 1PH822. up to 3500 rpm (3) Speed ranges: 1PH818. up to 3000 rpm, 1PH822. up to 2000 rpm 1. Connect the power supply in the terminal box. The terminal diagram is in the terminal box cover. Terminal box of the external fan Cable entry 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 205 Motor components and options 4.2 Options NOTICE Incorrect direction of rotation The external fan is only suitable for one direction of rotation. Operation with the wrong direction of rotation can destroy the motor. * If necessary, change the direction of rotation by interchanging two phase conductors in the terminal box. The direction of rotation arrow and the direction of rotation of the fan impeller can be seen at the rear of the fan. Throttle plate for operation at 60 Hz When operated from a 60 Hz line supply, you require the air discharge throttle plate provided in the terminal box. NOTICE Operation at 60 Hz The external fan motor can be damaged if it is operated on a 60 Hz line supply without an air discharge throttle plate. * Screw the air discharge throttle plate to the air discharge mesh. 4.2.10 Chain of PTC thermistors for alarm and trip (option A12) Overview In the 1PH8 motors, in addition to the standard temperature sensor in the stator winding (see Ch. "Thermal motor protection"), a chain of PTC thermistors for alarm and trip can be ordered with option A12. The chain of PTC thermistors can also monitor the winding temperature. PTC thermistors are thermistors that exhibit a sudden increase in resistance at a certain trigger temperature. The trip units detect this resistance change and signal the trigger temperature. PTC thermistors are standardized in DIN 44081. Circuit design Option A12 consists of two chains of PTC thermistors, each with 3 PTC thermistors for alarm and trip. The chain of PTC thermistors is installed in the phase elements on the winding overhang. The temperature difference between alarm and trip is 10 K. The terminal designations for the two connection ends of the chain of PTC thermistors for alarm are 1TP1 and 1TP2; the terminal designations for the two connection ends of the PTC thermistor circuit for tripping are 2TP1 and 2TP2. 1PH8 main motors 206 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Motor components and options 4.2 Options The circuit diagram and the terminal assignments are provided in the terminal box of the 1PH8 motor. Figure 4-17 Chains of PTC thermistors option A12 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 207 Motor components and options 4.2 Options 1PH8 main motors 208 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 5 Configuration 5.1 Configuring software 5.1.1 SIZER configuration tool Overview The SIZER calculation tool supports you in the technical dimensioning of the hardware and firmware components required for a drive task. SIZER supports the following configuration steps: Configuring the power supply Designing the motor and gearbox, including calculation of mechanical transmission elements Configuring the drive components Compiling the required accessories Selection of the line-side and motor-side power options The configuration process produces the following results: A parts list of components required (Export to Excel) Technical specifications of the system Characteristic curves Comments on system reactions Installation information of the drive and control components Energy considerations of the configured drive systems You will find further information on the Internet at: SIZER (https://support.industry.siemens.com/cs/document/54992004/sizer-for-siemensdrives?dti=0&pnid=13434&lc=en-WW) Table 5- 1 Article number for SIZER for SIEMENS Drives Configuration tool Article no. of the DVD SIZER for SIEMENS Drives 6SL3070-0AA00-0AG0 German/English 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 209 Configuration 5.1 Configuring software Minimum system requirements PG or PC with PentiumTM III 800 MHz (recommended > 1 GHz) 512 MB RAM (1 GB recommended) At least 4.1 GB free hard disk space In addition, 100 MB free hard disk space on the Windows system drive Screen resolution 1024 x 768 pixels (1280 x 1024 pixels recommended) WindowsTM 7 Professional (32/64-bit), 7 Enterprise (32/64-bit), 7 Ultimate (32/64-bit), 7 Home (32/64-bit), Vista Business, XP Professional SP2, XP Home SP2, XP 64-bit SP2 Microsoft Internet Explorer 5.5 SP2 1PH8 main motors 210 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Configuration 5.2 Procedure when engineering 5.2 Procedure when engineering 5.2.1 SINAMICS configuring procedure Motion Control 1PH8 motors are optimized for motion control applications. They execute linear or rotary movements within a defined movement cycle. All movements must be performed in a timeoptimized manner. As a result of these considerations, 1PH8 motors must meet the following requirements: High dynamic response, e.g. short rise times Capable of overload, i.e. high acceleration margin Wide control range, i.e. high resolution for precise positioning. The following table "Configuring procedure" is valid for synchronous and induction motors. General procedure when engineering The function description of the machine provides the basis when engineering the drive application. The components are selected according to physical interdependencies and the selection process is usually carried out in the following sequence of steps: Table 5- 2 Planning Step Description of configuration activity 1. Clarification of type of drive 2. Definition of supplementary conditions and integration into an automation system 3. Definition of the load, calculation of the maximum load torque and selection of the motor 4. Selection of the SINAMICS Motor Module 5. Repetition of steps 3 and 4 for additional axes 6. Calculation of the required DC link power and selection of the SINAMICS Line Module 7. Selection of the line-side options (main switch, fuses, line filters, etc.) 8. Specification of the required control performance and selection of the Control Unit, definition of component cabling 9. Definition of other system components (e.g. braking resistors) 10. Calculation of the current demand of the 24 V DC supply for the components and specification of the power supplies (SITOP devices, Control Supply Modules) 11. Selection of the components for the connection system 12. Configuration of drive line-up components 13. Calculation of the required cable cross sections for power supply and motor connections 14. Inclusion of mandatory installation clearances See the next chapter See catalog 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 211 Configuration 5.2 Procedure when engineering Clarification of the type of drive The motor is selected on the basis of the required torque, which is defined by the application, e.g. traveling drives, hoisting drives, test stands, centrifuges, paper and rolling mill drives, feed drives or main spindle drives. Gearboxes to convert motion or to adapt the motor speed and motor torque to the load conditions must also be considered. As well as the load torque, which is determined by the application, the following mechanical data is among those required to calculate the torque to be provided by the motor: Masses to be moved Diameter of the drive wheel Leadscrew pitch, gear ratios Frictional resistance Mechanical efficiency Traversing paths Maximum velocity Maximum acceleration and maximum deceleration Cycle time You must decide whether synchronous or asynchronous motors (induction motors) are to be used. Synchronous motors are the best choice if it is important to have low envelope dimensions, low rotor moment of inertia and therefore maximum dynamic response ("Servo" control type). Asynchronous motors can be used to increase maximum speeds in the field-weakening range. Asynchronous motors for higher power ratings are also available. The following factors are especially important when engineering a drive application: The ambient temperatures and the installation altitude of the motors and drive components. Heat dissipation from the motors through forced ventilation or water cooling The motor-specific limiting characteristics provide the basis for defining the motors. These define the torque or power characteristic versus the speed and take into account the motor limits based on the DC-link voltage of the Power Module or Motor Module. The DC-link voltage is in turn dependent on the supply voltage and, in the case of torque drives, on the type of Line Module. Other constraints apply when integrating the drives into an automation environment such as SINUMERIK or SIMOTION. The motor is selected based on the load which is specified by the application. Different characteristic curves must be used for different load events. The following operating scenarios have been defined: Duty cycle with constant ON period. Duty cycles with varying ON period. Free duty cycle. 1PH8 main motors 212 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Configuration 5.2 Procedure when engineering The objective is to identify characteristic torque and speed operating points that can be used as a basis for selecting the motor depending on the load. 5.2.2 Specifying the duty cycle Duty cycles with constant ON period For duty cycles with constant ON period, there are specific requirements for the torque characteristic curve as a function of the speed, for example: M = constant, M ~ n2, M ~ n or P = constant. Figure 5-1 S1 duty (continuous operation) These drives typically operate at a specific operating point. Drives such as these are dimensioned for a base load. The base load torque must lie below the S1 characteristic curve. An overload rating is provided for transient overloads (e.g. during acceleration). The overload current must be calculated relative to the required overload torque. The peak torque must lie below the voltage limiting characteristic. 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 213 Configuration 5.2 Procedure when engineering Duty cycles with varying ON period As well as continuous duty (S1), standard intermittent duty types (S6) are also defined for duty cycles with varying ON periods. This is a mode of operation consisting of a series of similar cycles, each one comprising one time period with a constant load and one idle time. There is no pause. Figure 5-2 S6 duty (continuous duty with intermittent load) Fixed variables (overload factors) are usually applied for the relative ON period: S6 - 60% S6 - 40% S6 - 25% The overload factors for the corresponding intermittent duty types (S6) referred to the S1 characteristic (continuous duty) can be found in Chapter "Technical data and characteristics." For the induction motors, the S6 characteristics are shown in addition to the S1 characteristic (see Chapter "Technical data and characteristics"). Note S3 duty The overload factors for continuous duty with intermittent load (S6) can also be applied for the S3 intermittent duty types (S3-60%, S3-40% or S3-25%) for 1PH8 motors with forced ventilation or water cooling. 1PH8 main motors 214 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Configuration 5.2 Procedure when engineering Free duty cycle A load duty cycle defines the characteristics of the motor speed and the torque with respect to time. Figure 5-3 Example of a duty cycle A load torque is specified for each time period. In addition to the load torque, the average load moment of inertia and motor moment of inertia must be taken into account for acceleration. It may be necessary to take into account a frictional torque that opposes the direction of motion. For gearbox mounting: In determining the load and acceleration torque required by the motor, the gear ratio and the gear efficiency must be considered. A higher gear ratio increases positioning accuracy in terms of encoder resolution. For any given motor encoder resolution, as the gear ratio increases, so does the resolution of the machine position to be detected. Note Duty cycles in the field weakening range For duty cycles in the field weakening range, the drive system must be engineered using the SIZER engineering tool. Permissible motor torque Once the application has been defined and specified, the maximum motor torque is calculated. Generally, the maximum motor torque is required when accelerating. The load torque and the torque required to accelerate the motor are added. The maximum motor torque is then verified with the limiting characteristic curves of the motors. 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 215 Configuration 5.2 Procedure when engineering The following criteria must be taken into account when selecting the motor: The dynamic limits must be adhered to, i.e. all speed-torque points of the relevant load event must lie below the relevant limiting characteristic curve. The thermal limits must be adhered to, i.e. the rms motor torque at the average motor speed resulting from the duty cycle must lie below the S1 characteristic curve (continuous duty). The rms value of the motor current within a duty cycle must be less than the rated motor current. In the field-weakening range, the permissible motor torque is restricted by the voltage limit characteristic (stability limit). Note Rated pulse frequencies The rated motor data is valid only for 4 kHz (booksize or blocksize motor modules) or 2 kHz (chassis motor module). Operation of the motors with rated pulse frequencies < 2 kHz is not permitted! 5.2.3 Selecting induction motors Characteristic curves for asynchronous motors The speed-power diagrams P = f(n) and the speed-torque diagrams M = f(n) for operation with the SINAMICS converter system are described in the motor characteristics (see Chapter "Technical data and characteristics"). Depending on the motor variant, the S1 characteristic (continuous operation) is available from standstill to rated point with maximum possible thermal torque, or passes through the constant-torque range. The power increases in proportion to speed depending on the available torque. This is then followed by a constant-power range where the field is weakened (fieldweakening range). The field-weakening range is limited by the voltage limit. For the induction motors, the S6 characteristics are shown in addition to the S1 characteristic (see Chapter "Technical data and characteristics"). 1PH8 main motors 216 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Configuration 5.2 Procedure when engineering Figure 5-4 Typical speed/power diagram for 1PH8 asynchronous motors In order that safe, reliable operation is guaranteed even when the line supply voltage fluctuates and the motor parameters vary, a safety margin of at least 10% should always be maintained to the voltage limit at every operating point depending on the type of supply voltage of the Motor Module (inverter) and Infeed Module. Note For the configuring of main spindle applications for machine tools, the characteristics for the supply voltage "ALM 400 V" include up to two additional ancillary rated points with which extended field-weakening operation can be configured. In this case, the range of constant power starts at the ancillary rated point and ends at the associated point n2. The rest of the characteristic is the same as the S1 characteristic in the diagram. Asynchronous motors have a high overload capacity in the constant power range. The theoretical curve of the maximum permissible overload capacity is shown as a limit in the characteristic diagrams and corresponds to value Pmax. 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 217 Configuration 5.2 Procedure when engineering 5.2.4 Selecting synchronous motors Characteristic curves for synchronous motors The S1 characteristic (continuous operation) up to rated point for synchronous motors is similar to the S1 characteristic for asynchronous motors. The S1 characteristic represents the thermally maximum possible continuous torque that can be produced. The S1 power increases with the speed depending on the available torque up to approximately the rated speed. This is followed by an area with reduced power characterized by increasing iron and friction losses, as well as the increase of negative field voltage with increasing speed due to the constant field of the synchronous rotor. Figure 5-5 Typical speed/power diagram for 1PH8 three-phase synchronous motors Note Like those for induction motors, the data sheets for the supply voltage "ALM 400V" include additional ancillary rated points for the configuring of main spindle applications for machine tools. These allow an extended speed range to be configured. The theoretical curve of the maximum permissible overload capacity is shown as a limit in the characteristic diagrams and corresponds to value Pmax. Note Voltage limitation A SINAMICS Voltage Protection Module (VPM) is required for operation at speeds of nmax,Inv and above. Voltage Protection Modules are available for rated currents up to 200 A. For further information, please refer to the SINAMICS S120 configuration manuals. 1PH8 main motors 218 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Configuration 5.3 Different rated points for induction motors 5.3 Different rated points for induction motors Basically, all 1PH8 induction motors can be configured based on a total of 4 characteristics and therefore also 4 rated points (operating points). The rated points are also stamped on the motor nameplate. For correct configuration, the line voltage and the line infeed are relevant for choosing the characteristics and rated points. Table 5- 3 Definition of the characteristics and rated points: Characteristics order Converter system Line voltage Supply infeed Remarks 1 SINAMICS 400 V 3 AC Smart/Basic Line Module (SLM/BLM) Infeed with Smart/Basic Mode nonregulated (converter output voltages up to 380 V) 2 SINAMICS 400 V 3 AC Active Line Module (ALM) Infeed with Active Mode regulated (converter output voltages up to 425 V) 3 SINAMICS 480 V 3 AC Smart/Basic Line Module (SLM/BLM) Infeed with Smart/Basic Mode nonregulated (converter output voltages up to 460 V) 4 SINAMICS 480 V 3 AC Active Line Module (ALM) Infeed with Active Mode regulated (converter output voltages up to 500 V) Note For water-cooled induction motors with shaft heights 180, 225, and 280, the characteristic order "4" is not shown. These motors therefore do not have a 4th rated point for "ALM 480V" on the motor nameplate. For configuration of the line infeed "ALM 480V," the data of the characteristic order "3" must be accepted. 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 219 Configuration 5.3 Different rated points for induction motors Within the characteristic for SINAMICS, 400V 3 AC, ALM (2nd order, see table), two (sometimes also three) different rated speeds are stated. The rated speeds that are additional to the first rated speed stated are termed ancillary rated points and enable configuration for extended field weakening operation. This type of configuration is often used for main-spindle applications on machine tools. It is especially important for the migration from old products, such as 1PH4, 1PH7, 1PM4/6, and 1PL6. Table 5- 4 SINAMICS, 3-ph. 400 V AC, Active Line Module, (ALM), 1PH8135-G2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,300 31.0 129 61 8,000 10,000 15,000 4,500 4,500 320 148 170 73 2,000 29.0 138 64 5,250 1,500 23.1 147 63 7,300 1) 1) 1PH8 main motors 220 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Configuration 5.3 Different rated points for induction motors 1) Ancillary rated point that permits configuration for extended field-weakening operation (e.g. main-spindle application for machine tools). In this case, the range of constant power starts at the ancillary rated point and ends at the associated point n2. The rest of the characteristic is the same as the S1 characteristic in the diagram. The ancillary rated points have the following advantages for configuration: Direct comparability of the power and torque at a rated speed with the old products such as 1PH4, 1PH7, 1PM4/6, and 1PL6. (For the old products, lower rated speeds than for 1PH8 are usually specified.) Configuration for an extended field-weakening operation. Note For the motor data for SINAMICS, only the rated point is stored. The ancillary rated points cannot be entered; they are only required for better configuration. Example of migration from 1PH7 to 1PH8: Motor 1PH7226-__F Rated point for SINAMICS, 400 V 3 AC, ALM 130 kW, 1500 rpm, 828 Nm Motor 1PH8226-1_F Rated point for SINAMICS, 400 V 3 AC, ALM 135 kW, 1750 rpm, 737 Nm Ancillary rated point for SINAMICS, 400 V 3 AC, ALM 130 kW, 1500 rpm, 828 Nm (comparable with 1PH7226-__F) 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 221 Configuration 5.4 Configuration for SINAMICS G 5.4 Configuration for SINAMICS G Configuration conditions The 1PH8 induction motors can also be configured for operation on SINAMICS G120, G130, and G150 if certain configuration conditions are met: 1PH8 in induction version SINAMICS G120 with PM240 or PM240-2 and CU modules CU240B-2 and CU240E-2 with firmware version 4.5 or CU250, vector control (encoderless) SINAMICS G130/G150 and CU module CU320-2 with firmware version 4.5, vector control (encoderless or with incremental encoder HTL) System restrictions: 1PH8 SH 80 to SH 160 Pulse frequency 4 kHz 1PH8 SH 180 to SH 280 Pulse frequency 2 kHz Maximum permissible output frequency for PM240 or PM240-2: 240 Hz (means n_max = 7000 rpm) System classification - characteristics: Only the characteristics of 1PH8 can be used for the non-regulated infeed. Characteristics order Converter system Line voltage Supply infeed Remarks 1 SINAMICS 400 V 3 AC Smart/Basic Line Module (SLM/BLM) Infeed with Smart/Basic Mode non-regulated (converter output voltages up to 380 V) 3 SINAMICS 480 V 3 AC Smart/Basic Line Module (SLM/BLM) Infeed with Smart/Basic Mode non-regulated (converter output voltages up to 460 V) 1PH8 main motors 222 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Configuration 5.5 Configuration for 1PH808 Premium Performance 5.5 Configuration for 1PH808 Premium Performance The 1PH8 motors in the "Premium Performance" variant have been developed specially for spindle drives for modern "drilling & tapping centers" and are characterized by higher performance data, such as: High maximum speeds (24,000 rpm) Low intrinsic moment of inertia High overload capability Due to the higher performance data, the 1PH8 motors have been designed for better configuration, in particular, for the SINAMICS S120 Motor Module Booksize, Booksize Combi, and the new Booksize Combi Module. In the characteristics (Chapter "Technical data and characteristics"), in addition to the rated point and the necessary pulse frequency, the maximum torques, maximum currents, and maximum powers permissible for the specific Motor Module are specified. In this way, different overload requirements can be simply configured. The typical intermittent duties S610%, S6-25%, and S6-40% for a "Drilling & Tapping Center" are also stated in the characteristics. Table 5- 5 Abbreviation Explanation of the symbols in the characteristic curves Unit Description nN rpm Rated speed PN kW Rated power MN Nm Rated torque IN A Rated current n2 rpm Maximum operating speed in field-weakening range (limits range of constant power) nmax rpm Maximum permissible speed with version "Premium Performance" Imax1 A Maximum permissible short-time current at Mmax1 for Motor Module Booksize Imax2 A Maximum permissible short-time current at Mmax2 for Motor Module Booksize Combi Imax3 A Maximum permissible short-time current at Mmax3 for Motor Module Booksize Combi (upgrade) Mmax1 Nm Maximum permissible short-time torque for Motor Module Booksize Mmax2 Nm Maximum permissible short-time torque for Motor Module Booksize Combi Mmax3 Nm Maximum permissible short-time torque for Motor Module Booksize Combi (upgrade) Pmax1 Nm Maximum permissible short-time power for Motor Module Booksize Pmax2 Nm Maximum permissible short-time power for Motor Module Booksize Combi 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 223 Configuration 5.5 Configuration for 1PH808 Premium Performance Pmax3 Nm Maximum permissible short-time power for Motor Module Booksize Combi (upgrade) fcycle kHz Rated pulse frequency Note Parameters must be adapted when commissioning Motors with the "Premium Performance" bearing version are presently not plug & play components. Even after automatically commissioning the motors with DRIVE-CLiQ, the commissioning engineer must adapt the appropriate parameters. Example: Motors with V and W winding versions (10th position of the Article No.) require a 8 kHz pulse frequency. Presently, this value is not automatically set. Further, for these motors, the current controller must be adapted. These parameters are currently not saved in the DRIVE-CLiQ interface data and must be modified manually by the commissioning engineer. These motors may only be operated with a fast current controller (p1810.11=yes) when connected to the SINAMICS S120 drive system. In order that you can proceed precisely when commissioning the motors, please request the commissioning regulations from your Siemens Service Center. The contact data is provided in the introduction under Technical support. 1PH8 main motors 224 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors 6.1.1 Technical data 6 The technical data of the relevant motor version are defined by four rated operating points in the tables. These four rated points also correspond to the data stamped on the rating plate of the motor and to the data listed in the selection and ordering data sections of catalog NC 62 and D21.4. Table 6- 1 Explanation of the abbreviations used Abbreviation Unit Description Prated kW Rated power Mrated Nm Rated torque Irated A Rated current Urated V Rated voltage frated Hz Rated frequency nrated rpm Rated speed cos - Power factor - Efficiency (rated point sine-wave operation or 1st order fundamental wave) J kgm2 Moment of inertia Tth min Thermal time constant I A Magnetizing current P_cool kW Heat loss to be dissipated on water-cooled motors m kg Weight nmax1 *) rpm Maximum permissible speed with bearing type "Standard or Increased Speed" nmax2 rpm Maximum permissible speed with bearing type "Performance" nmax3 rpm Maximum permissible speed with bearing type "High Performance" nmax,Br rpm Maximum permissible speed with bearing type "Advanced Lifetime" or built-on holding brake n2 rpm Maximum operating speed in field-weakening range (borders range of constant power) Mmax Nm Maximum permissible short-time torque for dynamic processes Imax A Maximum permissible short-time current at Mmax 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 225 Technical data and characteristics 6.1 Induction motors Abbreviation Unit Description M0 Nm Torque (S1) at zero speed I0 A Current (S1) at M0 *) With the bearing for increased radial forces (14th data position = F), the maximum permissible speed for shaft heights 100, 132, and 160 is smaller than the maximum permissible speed stated in the characteristics for the bearings for Standard or increased speed. Maximum permissible speed with the bearing for increased radial forces: Shaft height 100: nmax1 = 7,000 rpm Shaft height 132: nmax1 = 6,500 rpm Shaft height 160: nmax1 = 5,300 rpm 6.1.1.1 Table 6- 2 Shaft height 80 - forced ventilation 1PH8 shaft height 80, forced ventilation (basic data) Motor type Supply voltage Prated Mrate Irated Urated frated nrated [kW] d [A] [V] [Hz] [rpm] [Nm] cos J Tth I m [kgm2] [min] [A] [kg] 0.0064 10 3.8 32 1PH8083-1F SLM/BLM 400 V 2.8 18 7.5 346 53.3 1,500 0.80 0.809 Y connection ALM 400 V 3.3 18 7.5 398 61.9 1,750 0.80 0.831 3.8 SLM/BLM 480 V 3.7 18 7.6 447 70.0 2,000 0.79 0.850 3.7 ALM 480 V 4.1 18 7.6 480 76.2 2,200 0.82 0.850 3.6 1PH8083-1G SLM/BLM 400 V 3.7 18 11.6 293 70.2 2,000 0.79 0.832 5.7 Y connection ALM 400 V 4.1 17 11.3 332 80.0 2,300 0.78 0.852 5.7 SLM/BLM 480 V 4.6 17 11.2 376 91.6 2,650 0.78 0.862 5.7 ALM 480 V 4.8 16 11.3 400 96.4 2,800 0.76 0.868 5.8 1PH8083-1M SLM/BLM 400 V 4.1 13 13.6 298 102.6 3,000 0.74 0.869 7.3 Y connection ALM 400 V 4.5 13 13.5 327 113.8 3,300 0.74 0.875 7.3 SLM/BLM 480 V 4.9 13 14 355 122.6 3,600 0.74 0.881 7.3 ALM 480 V 5.3 13 14 372 132.8 3,900 0.76 0.870 7.2 1PH8083-1N SLM/BLM 400 V 4.8 10 17 300 152.3 4,500 0.70 0.860 9.5 Y connection ALM 400 V 5.3 10 17 335 168.9 5,000 0.69 0.870 9.7 SLM/BLM 480 V 5.5 10 16.5 350 185.7 5,500 0.71 0.870 9.0 ALM 480 V 5.0 8 15.9 382 202.1 6,000 0.66 0.850 9.1 1PH8087-1F SLM/BLM 400 V 3.7 24 10 336 53.2 1,500 0.81 0.817 Y connection ALM 400 V 4.3 23 10 396 61.4 1,750 0.78 0.838 5.3 SLM/BLM 480 V 4.9 23 10 435 69.9 2,000 0.80 0.864 4.9 0.0089 10 4.9 ALM 480 V 5.3 23 10 480 76.3 2,200 0.78 0.870 5.1 1PH8087-1G SLM/BLM 400 V 4.9 23 14.1 320 69.8 2,000 0.78 0.853 7.3 Y connection ALM 400 V 5.4 22 13.7 353 79.8 2,300 0.78 0.859 6.8 SLM/BLM 480 V 6.0 22 13.6 390 91.6 2,650 0.79 0.884 6.5 ALM 480 V 6.3 21 13.5 425 96.5 2,800 0.77 0.870 6.8 1PH8087-1M SLM/BLM 400 V 4.8 15 17.3 284 102.2 3,000 0.72 0.871 9.6 Y connection ALM 400 V 5.2 15 17.1 303 112.4 3,300 0.73 0.878 9.2 SLM/BLM 480 V 5.7 15 17.1 329 122.4 3,600 0.73 0.878 9.2 39 1PH8 main motors 226 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Motor type Supply voltage Prated Mrate Irated Urated frated nrated [kW] d [A] [V] [Hz] [rpm] [Nm] cos J Tth I m [kgm2] [min] [A] [kg] ALM 480 V 6.0 15 17.1 357 132.4 3,900 0.73 0.890 9.2 1PH8087-1N SLM/BLM 400 V 5.8 12 19.5 315 152.1 4,500 0.70 0.871 11.0 Y connection ALM 400 V 6.5 12 19.5 335 169.0 5,000 0.73 0.878 10.4 SLM/BLM 480 V 6.9 12 19 370 185.6 5,500 0.71 0.878 10.5 ALM 480 V 7.0 11 19 415 202.1 6,000 0.68 0.860 10.5 Table 6- 3 1PH8 shaft height 80 forced ventilation - Premium Performance (supplementary basic data) Motor type 6.1.1.2 Table 6- 4 J [kgm2] Tth [min] 1PH8081-1U Y connection 0.0045 10 1PH8081-1W Y connection 0.0045 10 1PH8081-1V Y connection 0.0045 10 1PH8083-1W Y connection 0.0064 10 1PH8083-1V Y connection 0.0064 10 1PH8087-1V Y connection 0.0089 10 Shaft height 100 - forced ventilation 1PH8 shaft height 100, forced ventilation (basic data) Motor type Supply voltage Prated Mrated Irated Urated frated nrated [kW] [Nm] [A] [V] [Hz] [rpm] cos J Tth I m [kgm2] [min] [A] [kg] 0.0138 20 6.0 42 1PH8101-1F SLM/BLM 400 V 3.7 24 12.5 265 52.4 1,500 0.80 0.835 Y connection ALM 400 V 4.3 23 12.5 304 60.9 1,750 0.80 0.852 6.0 SLM/BLM 480 V 4.7 22 12.5 343 69.0 2,000 0.79 0.871 6.0 ALM 480 V 5.1 22 12.5 363 76.0 2,200 0.82 0.870 6.0 1PH8101-1S SLM/BLM 400 V 3.7 24 13.2 253 52.4 1,500 0.80 0.830 6.3 Y connection ALM 400 V 4.9 23 13.2 328 69.2 2,000 0.80 0.870 6.3 SLM/BLM 480 V 6.2 24 13.2 404 85.9 2,500 0.80 0.890 6.2 ALM 480 V 7.4 24 13.2 480 102.5 3,000 0.79 0.900 6.3 1PH8101-1S SLM/BLM 400 V 3.7 9 13.5 289 134.6 4,000 0.69 0.890 7.8 connection ALM 400 V 4.9 9 13.5 360 168.0 5,000 0.70 0.900 7.8 SLM/BLM 480 V 6.2 10 13 460 201.3 6,000 0.68 0.910 8.5 ALM 480 V 7.2 10 13 503 234.8 7,000 0.72 0.910 7.8 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 227 Technical data and characteristics 6.1 Induction motors Motor type Supply voltage Prated Mrated Irated Urated frated nrated [kW] [Nm] [A] [V] [Hz] [rpm] cos J Tth I m [kgm2] [min] [A] [kg] 0.0172 20 4.6 51 1PH8103-1D SLM/BLM 400 V 3.7 35 10 333 35.8 1,000 0.82 0.814 Y connection ALM 400 V 4.3 36 10 380 40.9 1,150 0.81 0.824 4.8 SLM/BLM 480 V 4.7 33 9.7 423 47.3 1,350 0.82 0.848 4.4 ALM 480 V 5.2 33 9.7 470 52.2 1,500 0.81 0.850 4.6 1PH8103-1F SLM/BLM 400 V 5.5 35 13.5 368 52.4 1,500 0.80 0.852 6.5 Y connection ALM 400 V 6.3 34 13.1 412 60.8 1,750 0.81 0.859 6.0 SLM/BLM 480 V 7.0 33 12.7 460 69.1 2,000 0.81 0.894 5.8 ALM 480 V 7.7 33 12.7 480 76.1 2,200 0.83 0.880 5.8 1PH8103-1G SLM/BLM 400 V 7.0 33 17.5 345 69.0 2,000 0.79 0.877 8.7 Y connection ALM 400 V 7.5 31 17 382 78.9 2,300 0.79 0.891 8.1 SLM/BLM 480 V 8.0 29 16 434 90.4 2,650 0.78 0.913 8.1 ALM 480 V 8.5 29 16 455 95.3 2,800 0.78 0.900 8.1 1PH8103-1M SLM/BLM 400 V 8.4 27 25.7 297 102.1 3,000 0.78 0.900 12.2 Y connection ALM 400 V 9.3 27 25.7 326 112.1 3,300 0.78 0.900 12.2 SLM/BLM 480 V 10.0 27 25.4 355 122.1 3,600 0.77 0.910 12.3 ALM 480V 10.8 26 25 132.1 3,900 0.77 0.900 12.2 1PH8105-1F SLM/BLM 400 V 7.0 45 17.5 348 51.9 1,500 0.79 0.867 Y connection ALM 400 V 8.0 44 17.5 400 60.2 1,750 0.78 0.878 8.8 SLM/BLM 480 V 9.0 43 17 453 68.5 2,000 0.78 0.911 8.7 ALM 480 V 9.9 43 17 485 75.3 2,200 0.79 0.900 8.7 1PH8105-1S SLM/BLM 400 V 7.5 18 24 308 134.6 4,000 0.73 0.907 12.7 connection ALM 400 V 9.3 18 24 398 168.0 5,000 0.71 0.914 13.2 SLM/BLM 480 V 11.2 18 22 460 201.3 6,000 0.73 0.932 12.7 383 0.0252 20 8.8 ALM 480 V 13.0 18 22 500 234.9 7,000 0.76 0.920 12.7 1PH8105-1S SLM/BLM 400 V 7.5 48 23 285 52.1 1,500 0.79 0.864 11.5 Y connection ALM 400 V 10.0 48 23 366 68.9 2,000 0.80 0.891 10.9 SLM/BLM 480 V 12.5 48 23 451 85.5 2,500 0.80 0.922 10.9 ALM 480 V 14.5 46 22.8 495 102.7 3,000 0.83 0.910 SLM/BLM 400 V 2.5 60 8.8 290 15.5 400 0.85 0.690 ALM 400 V 3.2 61 8.8 347 19.0 500 0.85 0.730 4.3 SLM/BLM 480 V 3.8 60 8.8 406 22.0 600 0.82 0.760 4.4 ALM 480 V 4.4 60 8.7 452 25.5 700 0.83 0.790 4.0 1PH8107-1D SLM/BLM 400 V 6.3 60 17.5 307 35.5 1,000 0.82 0.834 8.2 Y connection ALM 400 V 7.2 60 17.5 348 40.6 1,150 0.82 0.852 8.2 SLM/BLM 480 V 8.0 57 17 400 47.1 1,350 0.80 0.867 8.2 ALM 480 V 8.8 56 17 440 52.0 1,500 0.80 0.860 8.2 1PH8107-1F SLM/BLM 400 V 9.0 57 23.5 330 52.2 1,500 0.81 0.869 10.8 Y connection ALM 400 V 10.0 55 22 380 60.4 1,750 0.80 0.878 10.9 SLM/BLM 480 V 11.0 53 21.5 428 68.6 2,000 0.79 0.901 10.8 1PH8107-1B Y connection 65 10.0 0.0289 20 4.1 ALM 480 V 12.1 53 21.5 470 75.2 2,200 0.78 0.900 10.9 1PH8107-1G SLM/BLM 400 V 10.5 50 26 355 68.6 2,000 0.78 0.897 12.9 Y connection ALM 400 V 12.0 50 26 406 78.6 2,300 0.78 0.909 13.0 SLM/BLM 480 V 13.0 47 24 460 90.0 2,650 0.77 0.932 12.8 ALM 480 V 13.7 47 24 480 95.1 2,800 0.77 0.920 12.8 73 1PH8 main motors 228 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Motor type Supply voltage Prated Mrated Irated Urated frated nrated [kW] [Nm] [A] [V] [Hz] [rpm] cos J Tth I m [kgm2] [min] [A] [kg] 1PH8107-1M SLM/BLM 400 V 12.0 38 38 294 101.6 3,000 0.76 0.900 19.2 Y connection ALM 400 V 13.0 38 38 314 111.7 3,300 0.77 0.900 18.3 SLM/BLM 480 V 14.0 37 37.5 350 121.6 3,600 0.77 0.910 19.1 ALM 480 V 14.0 34 35 380 131.5 3,900 0.73 0.900 19.4 1PH8107-1S SLM/BLM 400 V 8.5 20 28 323 134.4 4,000 0.68 0.898 16.4 connection ALM 400 V 11.0 21 28 410 167.8 5,000 0.68 0.909 16.7 SLM/BLM 480 V 12.8 20 28 460 201.3 6,000 0.73 0.931 15.5 ALM 480 V 15.0 20 28 500 234.8 7,000 0.75 0.920 16 1PH8107-1S SLM/BLM 400 V 8.5 54 27 275 52.0 1,500 0.80 0.861 13.1 Y connection ALM 400 V 11.0 53 26.7 368 68.5 2,000 0.76 0.894 14.2 SLM/BLM 480 V 14.0 53 26.5 454 85.2 2,500 0.77 0.923 14.1 ALM 480 V 16.0 51 26 102.2 3,000 0.81 0.910 14.0 6.1.1.3 Table 6- 5 500 Shaft height 132 - forced ventilation 1PH8 shaft height 132, forced ventilation (basic data) Motor type Prated Mrated Irated Urat- frated nrated [kW] [Nm] [A] ed [Hz] [rpm] SLM/BLM 400 V 2.9 69 9 272 14.7 400 0.88 0.770 0.059 ALM 400 V 3.6 69 9 328 18.0 500 0.88 0.810 3.5 SLM/BLM 480 V 4.3 68 9 384 21.3 600 0.88 0.830 3.5 ALM 480 V 4.9 67 9 450 24.6 700 0.85 0.834 3.5 SML/BLM 400 V 7.9 75 20 316 34.8 1,000 0.86 0.870 8.0 ALM 400 V 9.0 75 20 360 39.8 1,150 0.85 0.880 8.1 SML/BLM 480 V 10.6 75 20 416 46.5 1,350 0.86 0.900 7.9 ALM 480 V 11.7 74 20 460 51.5 1,500 0.85 0.910 8.0 1PH8131-1F SLM/BLM 400 V 11.0 70 24 360 51.4 1,500 0.84 0.899 10.4 Y connection ALM 400 V 13.0 71 24 416 59.9 1,750 0.85 0.914 10.3 SLM/BLM 480 V 15.0 72 24 460 68.2 2,000 0.86 0.931 9.2 ALM 480 V 16.5 72 24 500 75.0 2,200 0.87 0.920 10.0 1PH8131-1S SLM/BLM 400 V 11.0 26 40 285 134.1 4,000 0.75 0.893 18.1 connection ALM 400 V 14.6 28 40 360 167.5 5,000 0.78 0.897 18.5 SLM/BLM 480 V 18.0 29 35 453 200.8 6,000 0.75 0.908 20.2 1PH8131-1B Y connection 1PH8131-1D Y connection Supply voltage [V] cos J Tth I m [kgm2] [min] [A] [kg] 30 3.5 89 ALM 480 V 19.8 27 34 500 234.2 7,000 0.78 0.880 18.3 1PH8131-1S SLM/BLM 400 V 11.0 70 39 227 51.5 1,500 0.85 0.884 15.1 Y connection ALM 400 V 14.6 70 39 302 68.2 2,000 0.85 0.908 15.9 SLM/BLM 480 V 18.0 69 38 372 84.8 2,500 0.84 0.922 15.6 ALM 480 V 19.8 63 36.5 446 101.4 3,000 0.82 0.920 SLM/BLM 400 V 5.2 124 15.5 309 15.0 400 0.88 0.750 0.076 ALM 400 V 6.5 124 15.5 363 18.5 500 0.89 0.780 5.4 SLM/BLM 480 V 7.8 124 15.5 421 21.8 600 0.89 0.810 5.3 ALM 480 V 9.1 124 15.5 480 25.2 700 0.89 0.830 5.0 1PH8133-1B Y connection 16 30 6.2 106 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 229 Technical data and characteristics 6.1 Induction motors Motor type Supply voltage Prated Mrated Irated Urat- frated nrated [kW] [Nm] [A] ed [Hz] [rpm] [V] cos J Tth I m [kgm2] [min] [A] [kg] 1PH8133-1D SLM/BLM 400 V 12.0 115 30 319 35.0 1,000 0.88 0.871 10.1 Y connection ALM 400 V 13.5 112 29 361 40.1 1,150 0.88 0.884 10.7 SLM/BLM 480 V 15.0 106 28 417 46.5 1,350 0.86 0.904 10.7 ALM 480 V 16.6 106 28 459 51.5 1,500 0.86 0.900 10.6 1PH8133-1F SLM/BLM 400 V 15.0 96 34 342 51.3 1,500 0.85 0.899 14.2 Y connection ALM 400 V 17.5 96 34 392 59.8 1,750 0.85 0.913 13.6 SLM/BLM 480 V 20.0 96 34 445 68.2 2,000 0.85 0.933 13.5 ALM 480 V 22.0 96 34 480 74.8 2,200 0.87 0.930 13.6 1PH8133-1G SLM/BLM 400 V 20.0 96 45 350 68.1 2,000 0.85 0.919 18.1 Y connection ALM 400 V 22.5 93 44 400 78.1 2,300 0.84 0.933 18.1 SLM/BLM 480 V 24.0 86 41 456 89.6 2,650 0.83 0.949 18.1 ALM 480 V 25.0 85 41 480 94.7 2,800 0.83 0.920 18.1 SLM/BLM 400 V 6.4 153 18 320 15.2 400 0.90 0.740 0.094 ALM 400 V 8.0 153 18 405 18.5 500 0.90 0.780 5.6 SLM/BLM 480 V 9.6 153 18 443 21.9 600 0.90 0.810 5.6 1PH8135-1B Y connection 30 5.2 ALM 480 V 11.2 153 18 500 25.3 700 0.90 0.830 5.3 1PH8135-1F SLM/BLM 400 V 18.5 118 43 330 51.3 1,500 0.85 0.898 18.1 Y connection ALM 400 V 21.5 117 43 383 59.7 1,750 0.85 0.909 18.3 SLM/BLM 480 V 24.0 115 43 434 67.9 2,000 0.84 0.929 18.1 ALM 480 V 26.4 115 43 468 74.7 2,200 0.84 0.920 18.3 1PH8135-1G Y SML/BLM 400 V connection ALM 400 V 21.5 103 51 323 68.0 2,000 0.85 0.912 20.9 24.0 100 50 370 77.9 2,300 0.85 0.919 20.6 SML/BLM 480 V 26.0 94 48 424 89.6 2,650 0.84 0.923 20.6 ALM 480 V 26.0 89 47 440 94.6 2,800 0.84 0.924 20.0 1PH8135-1S SLM/BLM 400 V 18.5 44 51 364 134.0 4,000 0.76 0.912 23.3 connection ALM 400 V 24.5 47 52 425 167.5 5,000 0.81 0.939 22.8 SLM/BLM 480 V 30.5 49 50 460 201.0 6,000 0.86 0.941 20.0 ALM 480 V 32.0 44 51 510 235.0 7,000 0.85 0.910 20.0 1PH8135-1S SLM/BLM 400 V 18.5 118 51 283 51.3 1,500 0.85 0.901 21.1 Y connection ALM 400 V 24.5 117 51 372 68.0 2,000 0.85 0.917 20.9 SLM/BLM 480 V 30.5 117 50 460 84.6 2,500 0.85 0.949 20.8 ALM 480 V 35.0 111 51 510 102.0 3,000 0.88 0.940 SLM/BLM 400 V 6.9 165 18 323 14.7 400 0.88 0.790 0.109 ALM 400 V 8.6 165 18 391 18.1 500 0.88 0.820 6.7 SLM/BLM 480 V 10.3 165 18 458 21.4 600 0.88 0.850 6.8 ALM 480 V 11.5 157 17.5 500 24.9 700 0.89 0.860 5.5 1PH8137-1D SLM/BLM 400 V 17.0 162 43 307 34.8 1,000 0.88 0.881 15.1 Y connection ALM 400 V 19.5 162 43 350 39.9 1,150 0.88 0.891 16.1 SLM/BLM 480 V 22.0 156 42 404 46.4 1,350 0.86 0.902 15.9 ALM 480 V 24.0 153 41 447 51.5 1,500 0.86 0.890 15.9 1PH8137-1F SLM/BLM 400 V 22.0 140 56 308 51.3 1,500 0.84 0.904 24.2 Y connection ALM 400 V 25.0 136 56 352 59.6 1,750 0.85 0.907 23.1 SLM/BLM 480 V 28.0 134 55 401 67.9 2,000 0.84 0.931 23.1 ALM 480 V 30.0 130 53 440 74.6 2,200 0.83 0.920 23.2 1PH8137-1B Y connection 125 20.0 30 6.7 141 1PH8 main motors 230 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Motor type Supply voltage Prated Mrated Irated Urat- frated nrated [kW] [Nm] [A] ed [Hz] [rpm] [V] cos J Tth I m [kgm2] [min] [A] [kg] 1PH8137-1G SLM/BLM 400 V 28.0 134 60 350 68.1 2,000 0.87 0.924 21.5 Y connection ALM 400 V 29.0 120 56 398 77.9 2,300 0.86 0.929 21.9 SLM/BLM 480 V 30.0 108 52 460 89.4 2,650 0.83 0.941 22.4 ALM 480 V 31.0 106 52 494 94.4 2,800 0.82 0.920 22.0 1PH8137-1S SLM/BLM 400 V 22.0 53 55 383 134.0 4,000 0.76 0.907 27.6 connection ALM 400 V 27.5 53 56 425 167.5 5,000 0.83 0.919 22.5 SLM/BLM 480 V 33.0 53 55 460 201.0 6,000 0.87 0.942 20.0 ALM 480 V 37.0 50 53 510 235.0 7,000 0.87 0.920 20.0 1PH8137-1S SLM/BLM 400 V 22.0 140 56 308 51.3 1,500 0.84 0.902 24.2 Y connection ALM 400 V 29.0 138 56 400 68.0 2,000 0.85 0.931 22.7 SLM/BLM 480 V 36.0 138 56 460 84.9 2,500 0.89 0.951 17.4 ALM 480 V 37.0 118 54 510 101.5 3,000 0.89 0.940 16.0 nrated cos 6.1.1.4 Table 6- 6 Shaft height 160 - forced ventilation 1PH8 shaft height 160, forced ventilation (basic data) Motor Module Prated Mrated Irated Urated frated J [kgm2] Tth I m [min] [A] [kg] 35 8.1 196 [kW] [Nm] [A] [V] [Hz] [rpm] 1PH8163-1B SLM/BLM 400 V 9.5 227 30 260 14.3 400 0.91 0.828 0.216 Y connection ALM 400 V 12 229 30 325 17.6 500 0.89 0.819 8.9 SLM/BLM 480 V 14.5 231 30 370 21.0 600 0.90 0.851 8.1 ALM 480 V 16.9 231 30 427 24.4 700 0.90 0.880 8.1 1PH8163-1D SLM/BLM 400 V 22 210 55 300 34.2 1,000 0.89 0.909 17.3 Y connection ALM 400 V 25 208 55 343 39.2 1,150 0.88 0.915 17.5 SLM/BLM 480 V 28 198 52 400 45.8 1,350 0.88 0.924 17.7 ALM 480 V 31.0 197 52 442 50.9 1,500 0.88 0.930 17.5 1PH8163-1F SLM/BLM 400 V 30 191 71 319 50.8 1,500 0.87 0.923 25.6 Y connection ALM 400 V 34 186 70 366 59.2 1,750 0.87 0.926 24.6 SLM/BLM 480 V 37 177 68 416 67.4 2,000 0.86 0.932 24.6 ALM 480 V 40.7 177 68 456 74.2 2,200 0.88 0.940 24.5 1PH8163-1G SLM/BLM 400 V 36 172 83 324 67.5 2,000 0.88 0.929 28.1 Y connection ALM 400 V 38 158 78 370 77.4 2,300 0.86 0.935 28.2 SLM/BLM 480 V 40 144 76 390 89.2 2,650 0.89 0.936 23.1 ALM 480 V 42.0 143 75 447 94.1 2,800 0.85 0.930 1PH8165-1B SLM/BLM 400 V 13 310 36 300 14.1 400 0.86 0.826 0.232 28.1 Y connection ALM 400 V 16 306 36 365 17.5 500 0.85 0.830 14.8 SLM/BLM 480 V 19 302 35 420 20.8 600 0.88 0.850 12.0 ALM 480 V 22.0 300 35 475 24.3 700 0.88 0.900 14.5 1PH8165-1D SLM/BLM 400 V 28 267 71 292 34.2 1,000 0.89 0.914 22.2 Y connection ALM 400 V 31 257 69 333 39.2 1,150 0.88 0.921 20.9 SLM/BLM 480 V 34 241 66 387 45.8 1,350 0.86 0.928 22.5 ALM 480 V 37.7 240 65 430 50.8 1,500 0.88 0.930 22.5 35 14.9 230 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 231 Technical data and characteristics 6.1 Induction motors Motor Module Prated Mrated Irated Urated frated nrated [kW] [Nm] [A] [V] [Hz] [rpm] cos J Tth I m [kgm2] [min] [A] [kg] 1PH8165-1F SLM/BLM 400 V 37 236 78 350 50.8 1,500 0.88 0.926 27.0 Y connection ALM 400 V 41 224 76 400 59.1 1,750 0.88 0.934 25.8 SLM/BLM 480 V 45 215 75 440 67.5 2,000 0.89 0.936 23.6 ALM 480 V 49.5 215 75 493 74.2 2,200 0.88 0.950 25.1 1PH8165-1G SLM/BLM 400 V 41 196 88 350 67.4 2,000 0.87 0.927 32.4 Y connection ALM 400 V 44 183 85 394 77.4 2,300 0.86 0.932 31.0 SLM/BLM 480 V 50 180 85 440 89.0 2,650 0.87 0.932 28.9 ALM 480 V 50.0 171 81 483 94.1 2,800 0.87 0.940 31.9 6.1.1.5 Table 6- 7 Shaft height 180 - forced ventilation 1PH8 shaft height 180, degree of protection IP55, forced ventilation (basic data) Motor Module Prated Mrated Irated Urated frated nrated [kW] [Nm] [A] [V] [Hz] [rpm] cos J Tth I m [kgm2] [min] [A] [kg] 22 23 350 1PH8184-1B SLM/BLM 400 V 16.3 389 49 271 14.1 400 0.85 0.834 0.489 Y connection ALM 400 V 20.5 392 49 335 17.4 500 0.84 0.861 23 SLM/BLM 480 V 25 398 49 410 20.7 600 0.81 0.882 26 ALM 480 V 29 396 49 475 24.0 700 0.81 0.895 26 1PH8184-1C SLM/BLM 400 V 27 368 65 320 24.0 700 0.84 0.889 30 Y connection ALM 400 V 31 370 65 365 27.4 800 0.84 0.901 30 SLM/BLM 480 V 39 372 65 460 34.0 1,000 0.82 0.917 32 ALM 480 V 42 365 64 500 37.3 1,100 0.82 0.923 32 1PH8184-1D SLM/BLM 400 V 39 372 87 340 34.0 1,000 0.83 0.920 42 Y connection ALM 400 V 44 365 86 390 39.0 1,150 0.82 0.928 42 SLM/BLM 480 V 50 354 84 450 45.7 1,350 0.82 0.936 41 ALM 480 V 53 337 80 500 50.6 1,500 0.81 0.940 42 1PH8184-1F SLM/BLM 400 V 51 325 116 335 50.6 1,500 0.80 0.940 63 Y connection ALM 400 V 60 327 120 390 58.9 1,750 0.79 0.944 64 SLM/BLM 480 V 68 325 118 450 67.2 2,000 0.78 0.947 65 ALM 480 V 68 295 110 500 73.8 2,200 0.75 0.948 68 1PH81841L SLM/BLM 400 V 78 298 166 340 84.0 2,500 0.84 0.952 75 Y connection ALM 400 V 81 267 152 395 97.3 2,900 0.82 0.952 76 SLM/BLM/ALM 480 V 65 183 120 460 113.7 3,400 0.72 0.944 1PH8186-1B SLM/BLM 400 V 21.2 506 65 268 13.9 400 0.83 0.850 0.652 Y connection ALM 400 V 26.5 506 65 335 17.2 500 0.80 0.875 36 SLM/BLM 480 V 32 509 66 400 20.6 600 0.79 0.892 37 77 25 34 ALM 480 V 37 505 65 470 23.9 700 0.77 0.904 39 1PH8186-1C SLM/BLM 400 V 35 478 83 330 23.9 700 0.81 0.909 44 Y connection ALM 400 V 40 478 83 360 27.3 800 0.84 0.916 41 SLM/BLM 480 V 50 478 83 450 33.9 1,000 0.83 0.929 42 ALM 480 V 55 478 83 500 37.3 1,100 0.82 0.934 43 422 1PH8 main motors 232 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Motor Module Prated Mrated Irated Urated frated nrated [kW] [Nm] [A] [V] [Hz] [rpm] cos J Tth I m [kgm2] [min] [A] [kg] 1PH8186-1D SLM/BLM 400 V 51 487 112 340 34.0 1,000 0.83 0.926 56 Y connection ALM 400 V 58 482 112 390 38.9 1,150 0.82 0.933 57 SLM/BLM 480 V 67 474 112 450 45.6 1,350 0.82 0.939 55 ALM 480 V 73 465 110 500 50.6 1,500 0.82 0.943 56 1PH8186-1F SLM/BLM 400 V 74 471 166 330 50.6 1,500 0.83 0.945 82 Y connection ALM 400 V 85 464 164 385 58.9 1,750 0.82 0.949 83 SLM/BLM 480 V 94 449 160 445 67.2 2,000 0.80 0.952 86 ALM 480 V 94 408 140 490 74.1 2,200 0.84 0.948 63 1PH81861L SLM/BLM 400 V 106 405 230 335 83.9 2,500 0.84 0.955 107 Y connection ALM 400 V 101 333 198 385 97.2 2,900 0.80 0.954 106 SLM/BLM/ALM 480 V 81 228 158 455 113.7 3,400 0.69 0.943 109 6.1.1.6 Table 6- 8 Shaft height 180 - forced ventilation (open-circuit ventilation) 1PH8 shaft height 180, degree of protection IP23, forced ventilation, open-circuit ventilation (basic data) Motor Module Prated Mrated Irated Urated frated nrated [kW] [Nm] [A] [V] [Hz] [rpm] cos J Tth I m [kgm2] [min] [A] [kg] 26 25 350 1PH8184-1B SLM/BLM 400 V 24.5 585 67 300 14.3 400 0.88 0.801 0.489 Y connection ALM 400 V 30 573 65 370 17.6 500 0.86 0.840 27 SLM/BLM 480 V 36 573 64 440 20.9 600 0.85 0.863 28 ALM 480 V 42 573 65 500 24.2 700 0.85 0.877 27 1PH8184-1C SLM/BLM 400 V 40 546 94 320 24.5 700 0.90 0.852 27 Y connection ALM 400 V 45 537 91 365 27.8 800 0.90 0.872 28 SLM/BLM 480 V 57 544 90 460 34.4 1,000 0.89 0.896 30 ALM 480 V 62 538 89 500 37.7 1,100 0.88 0.921 30 1PH8184-1D SLM/BLM 400 V 57 544 120 340 34.4 1,000 0.89 0.899 39 Y connection ALM 400 V 65 540 120 390 39.4 1,150 0.88 0.911 39 SLM/BLM 480 V 74 523 118 450 46.0 1,350 0.88 0.922 39 ALM 480 V 76 484 108 500 50.9 1,500 0.87 0.931 40 1PH8184-1F SLM/BLM 400 V 76 484 162 335 50.9 1,500 0.87 0.931 61 Y connection ALM 400 V 89 486 162 390 59.3 1,750 0.87 0.937 61 SLM/BLM 480 V 98 468 156 450 67.5 2,000 0.85 0.943 63 ALM 480 V 98 425 144 500 74.1 2,200 0.83 0.947 66 1PH81841L SLM/BLM 400 V 100 382 205 340 84.2 2,500 0.87 0.949 74 Y connection ALM 400 V 113 372 200 395 97.5 2,900 0.87 0.952 75 SLM/BLM/ALM 480 V 113 317 176 460 114.1 3,400 0.85 0.953 75 1PH8186-1B SLM/BLM 400 V 31.5 752 88 290 14.2 400 0.87 0.822 0.652 Y connection ALM 400 V 40 764 88 355 17.5 500 0.87 0.850 38 SLM/BLM 480 V 48 764 88 430 20.8 600 0.84 0.874 41 29 37 ALM 480 V 56 764 88 500 24.1 700 0.83 0.889 43 1PH8186-1C SLM/BLM 400 V 52 709 116 330 24.3 700 0.89 0.885 41 Y connection ALM 400 V 60 716 120 360 27.7 800 0.90 0.891 38 SLM/BLM 480 V 74 707 116 450 34.3 1,000 0.89 0.912 39 ALM 480 V 80 695 114 500 37.6 1,100 0.88 0.921 41 422 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 233 Technical data and characteristics 6.1 Induction motors Motor Module Prated Mrated Irated Urated frated nrated [kW] [Nm] [A] [V] [Hz] [rpm] cos J Tth I m [kgm2] [min] [A] [kg] 1PH8186-1D SLM/BLM 400 V 74 707 156 340 34.3 1,000 0.89 0.908 53 Y connection ALM 400 V 85 706 154 390 39.3 1,150 0.89 0.918 54 SLM/BLM 480 V 98 693 152 450 45.9 1,350 0.89 0.928 53 ALM 480 V 105 669 148 500 50.9 1,500 0.88 0.935 54 1PH8186-1F SLM/BLM 400 V 108 688 225 330 50.9 1,500 0.89 0.936 79 Y connection ALM 400 V 125 682 225 385 59.2 1,750 0.88 0.942 80 SLM/BLM 480 V 135 645 210 445 67.5 2,000 0.87 0.948 83 ALM 480 V 135 586 196 490 74.1 2,200 0.85 0.952 85 1PH81861L SLM/BLM 400 V 130 497 270 335 84.1 2,500 0.87 0.954 105 Y connection ALM 400 V 150 494 270 385 97.4 2,900 0.87 0.955 105 SLM/BLM/ALM 480 V 130 365 210 455 113.9 3,400 0.82 0.954 108 6.1.1.7 Table 6- 9 Shaft height 225 - forced ventilation 1PH8 shaft height 225, degree of protection IP55, forced ventilation (basic data) Motor Module Prated Mrated Irated Urated frated nrated [kW] [Nm] [A] [V] [Hz] [rpm] cos J Tth I m [kgm2] [min] [A] [kg] 49 34 610 1PH8224-1B SLM/BLM 400 V 30.4 726 86 268 13.9 400 0.87 0.872 1.48 Y connection ALM 400 V 38 726 85 335 17.2 500 0.86 0.896 36 SLM/BLM 480 V 45 716 83 405 20.5 600 0.85 0.912 37 ALM 480 V 52 709 82 470 23.9 700 0.84 0.923 37 1PH8224-1C SLM/BLM 400 V 55 750 136 310 23.8 700 0.82 0.925 67 Y connection ALM 400 V 57 681 126 350 27.1 800 0.80 0.934 67 SLM/BLM 480 V 71 678 126 425 33.8 1,000 0.81 0.943 64 ALM 480 V 78 677 126 470 37.1 1,100 0.80 0.946 65 1PH8224-1D SLM/BLM 400 V 71 678 158 335 33.8 1,000 0.82 0.942 77 Y connection ALM 400 V 81 673 156 385 38.8 1,150 0.82 0.946 78 SLM/BLM 480 V 92 651 154 450 45.5 1,350 0.81 0.951 78 ALM 480 V 92 586 142 500 50.4 1,500 0.78 0.953 79 1PH8224-1F SLM/BLM 400 V 95 605 200 340 50.5 1,500 0.85 0.953 87 Y connection ALM 400 V 110 600 198 395 58.9 1,750 0.85 0.956 87 SLM/BLM 480 V 124 592 196 460 67.2 2,000 0.83 0.957 90 ALM 480 V 110 478 168 500 73.7 2,200 0.79 0.957 90 1PH82241L SLM/BLM 400 V 142 542 295 340 83.9 2,500 0.86 0.958 113 Y connection ALM 400 V 149 491 270 395 97.2 2,900 0.85 0.957 115 SLM/BLM/ALM 480 V 85 239 168 460 113.6 3,400 0.68 0.934 115 1PH8226-1B SLM/BLM 400 V 39.2 936 112 264 13.9 400 0.87 0.887 1.93 Y connection ALM 400 V 49 936 110 330 17.2 500 0.86 0.908 48 SLM/BLM 480 V 59 939 110 395 20.5 600 0.85 0.921 49 52 46 ALM 480 V 68 928 108 465 23.8 700 0.84 0.931 51 1PH8226-1C SLM/BLM 400 V 68 928 162 310 23.8 700 0.84 0.932 76 Y connection ALM 400 V 73 872 154 350 27.1 800 0.83 0.940 75 SLM/BLM 480 V 92 879 156 440 33.8 1,000 0.82 0.948 77 ALM 480 V 101 877 154 500 37.1 1,100 0.80 0.951 83 740 1PH8 main motors 234 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Motor Module Prated Mrated Irated Urated frated nrated [kW] [Nm] [A] [V] [Hz] [rpm] cos J Tth I m [kgm2] [min] [A] [kg] 1PH8226-1D SLM/BLM 400 V 92 879 194 340 33.8 1,000 0.85 0.944 86 Y connection ALM 400 V 105 872 192 390 38.8 1,150 0.85 0.949 86 SLM/BLM 480 V 120 849 188 460 45.5 1,350 0.84 0.954 88 ALM 480 V 120 764 174 500 50.4 1,500 0.83 0.957 85 1PH8226-1F SLM/BLM 400 V 130 828 270 340 50.5 1,500 0.85 0.957 119 Y connection ALM 400 V 135 737 250 395 58.8 1,750 0.83 0.960 119 SLM/BLM 480 V 153 731 245 450 67.1 2,000 0.83 0.961 119 ALM 480 V 130 564 205 500 73.7 2,200 0.76 0.958 123 1PH82261L SLM/BLM 400 V 168 642 350 335 83.8 2,500 0.86 0.961 151 Y connection ALM 400 V 185 609 335 390 97.1 2,900 0.85 0.960 152 SLM/BLM/ALM 480 V 90 253 205 460 113.5 3,400 0.60 0.926 1PH8228-1B SLM/BLM 400 V 48 1146 132 272 13.8 400 0.86 0.896 2.33 156 Y connection ALM 400 V 60 1146 132 340 17.2 500 0.85 0.914 59 SLM/BLM 480 V 72 1146 130 410 20.5 600 0.84 0.927 62 ALM 480 V 84 1146 130 480 23.8 700 0.83 0.935 63 1PH8228-1C SLM/BLM 400 V 82 1119 188 315 23.8 700 0.86 0.933 80 Y connection ALM 400 V 92 1098 182 360 27.2 800 0.86 0.941 80 SLM/BLM V 115 1098 182 450 33.8 1,000 0.85 0.949 82 ALM 480 V 126 1094 182 500 37.1 1,100 0.84 0.952 84 1PH8228-1D SLM/BLM 400 V 113 1079 235 340 33.9 1,000 0.87 0.948 97 Y connection ALM 400 V 129 1071 235 390 38.8 1,150 0.86 0.953 97 SLM/BLM 480 V 147 1040 225 460 45.5 1,350 0.86 0.957 99 ALM 480 V 147 936 210 500 50.5 1,500 0.85 0.960 96 1PH8228-1F SLM/BLM 400 V 160 1019 340 340 50.4 1,500 0.83 0.959 170 Y connection ALM 400 V 179 977 330 395 58.7 1,750 0.82 0.961 170 SLM/BLM 480 V 196 936 325 450 67.1 2,000 0.81 0.962 169 55 58 ALM 480 V 170 738 275 500 73.6 2,200 0.74 0.959 174 1PH82281L SLM/BLM 400 V 205 783 420 340 83.8 2,500 0.86 0.963 181 Y connection ALM 400 V 215 708 390 395 97.1 2,900 0.84 0.961 183 SLM/BLM/ALM 480 V 95 267 225 460 113.5 3,400 0.57 0.922 183 6.1.1.8 Table 6- 10 870 Shaft height 225 - forced ventilation (open-circuit ventilation) 1PH8 shaft height 225, degree of protection IP23, forced ventilation, open-circuit ventilation (basic data) Motor Module Prated Mrated Irated Urated frated nrated [kW] [Nm] [V] [Hz] [rpm] [A] cos J Tth I m [kgm2] [min] [A] [kg] 21 39 610 1PH8224-1B SLM/BLM 400 V 45 1074 114 300 14.1 400 0.89 0.849 1.48 Y connection ALM 400 V 55 1051 112 370 17.4 500 0.88 0.878 41 SLM/BLM 480 V 67 1066 118 410 20.9 600 0.90 0.883 35 ALM 480 V 67 914 500 24.0 700 0.86 0.914 41 1PH8224-1C SLM/BLM 400 V 80 1091 188 98 310 24.1 700 0.88 0.904 63 Y connection ALM 400 V 90 1074 184 350 27.4 800 0.88 0.914 63 SLM/BLM 480 V 105 1003 174 425 34.1 1,000 0.88 0.929 61 ALM 480 V 105 912 470 37.3 1,100 0.86 0.938 63 160 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 235 Technical data and characteristics 6.1 Induction motors Motor Module Prated Mrated Irated Urated frated nrated [kW] [Nm] [V] [Hz] [rpm] [A] cos J Tth I m [kgm2] [min] [A] [kg] 1PH8224-1D SLM/BLM 400 V 105 1003 220 335 34.1 1,000 0.88 0.926 73 Y connection ALM 400 V 120 997 220 385 39.1 1,150 0.88 0.934 74 SLM/BLM 480 V 137 969 215 450 45.7 1,350 0.87 0.941 75 ALM 480 V 137 872 194 500 50.6 1,500 0.86 0.947 77 1PH8224-1F SLM/BLM 400 V 142 904 290 340 50.8 1,500 0.89 0.942 84 Y connection ALM 400 V 165 900 285 395 59.2 1,750 0.89 0.946 84 SLM/BLM 480 V 178 850 265 460 67.4 2,000 0.88 0.952 88 ALM 480 V 178 773 250 500 74.0 2,200 0.87 0.954 88 1PH82241L SLM/BLM 400 V 178 680 355 340 84.1 2,500 0.89 0.954 112 Y connection ALM 400 V 205 675 355 395 97.4 2,900 0.89 0.955 113 SLM/BLM/ALM 480 V 205 576 310 460 114.0 3,400 0.87 0.954 1PH8226-1B SLM/BLM 400 V 57 1361 144 305 13.9 400 0.86 0.875 1.93 113 Y connection ALM 400 V 72 1375 144 375 17.3 500 0.86 0.895 60 SLM/BLM 480 V 87 1385 152 410 20.8 600 0.90 0.899 49 ALM 480 V 87 1187 128 500 23.9 700 0.85 0.924 58 1PH8226-1C SLM/BLM 400 V 106 1446 240 310 24.2 700 0.90 0.907 71 Y connection ALM 400 V 118 1409 235 350 27.5 800 0.90 0.918 71 SLM/BLM 480 V 146 1394 230 440 34.1 1,000 0.89 0.932 74 ALM 480 V 146 1268 205 500 37.3 1,100 0.87 0.942 81 1PH8226-1D SLM/BLM 400 V 135 1289 275 340 34.1 1,000 0.90 0.929 82 Y connection ALM 400 V 155 1287 270 390 39.1 1,150 0.90 0.936 83 SLM/BLM 480 V 172 1217 255 460 45.7 1,350 0.89 0.945 85 ALM 480 V 172 1095 240 500 50.7 1,500 0.88 0.950 83 1PH8226-1F SLM/BLM 400 V 175 1114 350 340 50.7 1,500 0.89 0.950 117 Y connection ALM 400 V 200 1091 350 390 59.0 1,750 0.89 0.954 114 SLM/BLM 480 V 220 1051 335 450 67.3 2,000 0.88 0.957 117 23 61 ALM 480 V 220 955 305 500 73.9 2,200 0.87 0.959 120 1PH82261L SLM/BLM 400 V 235 898 475 335 84.0 2,500 0.89 0.957 149 Y connection ALM 400 V 270 889 470 390 97.3 2,900 0.89 0.958 150 SLM/BLM/ALM 480 V 270 758 405 460 113.9 3,400 0.87 0.957 1PH8228-1B SLM/BLM 400 V 72 1719 176 305 14.0 400 0.88 0.878 2.33 Y connection ALM 400 V 90 1719 174 380 17.3 500 0.87 0.899 73 SLM/BLM 480 V 108 1719 188 410 20.8 600 0.90 0.902 57 ALM 480 V 108 1473 156 500 23.9 700 0.86 0.926 67 1PH8228-1C SLM/BLM 400 V 120 1637 265 315 24.1 700 0.91 0.91 75 Y connection ALM 400 V 135 1612 260 360 27.4 800 0.91 0.922 77 SLM/BLM 480 V 165 1576 250 450 34.1 1,000 0.90 0.936 79 ALM 480 V 165 1433 225 500 37.3 1,100 0.89 0.944 82 1PH8228-1D SLM/BLM 400 V 165 1576 330 340 34.1 1,000 0.91 0.933 93 Y connection ALM 400 V 190 1578 330 390 39.1 1,150 0.91 0.940 94 SLM/BLM 480 V 218 1542 320 460 45.7 1,350 0.90 0.947 96 ALM 480 V 218 1388 295 500 50.7 1,500 0.90 0.952 94 1PH8228-1F SLM/BLM 400 V 230 1464 465 340 50.6 1,500 0.88 0.953 166 Y connection ALM 400 V 265 1446 460 390 59.0 1,750 0.89 0.956 162 SLM/BLM 480 V 288 1375 440 450 67.3 2,000 0.88 0.959 166 740 153 25 69 870 1PH8 main motors 236 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Motor Module Prated Mrated Irated Urated frated nrated [kW] [Nm] [V] [Hz] [rpm] ALM 480 V 288 1250 405 500 73.9 2,200 0.86 0.960 171 1PH82281L SLM/BLM 400 V 265 1012 530 340 83.9 2,500 0.89 0.960 180 Y connection ALM 400 V 300 988 510 395 97.3 2,900 0.89 0.960 182 SLM/BLM/ALM 480 V 300 843 450 460 113.8 3,400 0.87 0.958 181 6.1.1.9 Table 6- 11 [A] cos J Tth I m [kgm2] [min] [A] [kg] Shaft height 280 - forced ventilation 1PH8 shaft height 280, degree of protection IP55, forced ventilation (basic data) Motor Module Prated Mrated Irated Urated frated nrated [kW] [Nm] [V] [Hz] [rpm] [A] cos J Tth I [kgm2] [min] [A] 1PH8284-1B1 SLM/BLM 400 V 63 1504 154 325 13.6 400 0.79 0.924 4.20 connection ALM 400 V 80 1529 154 395 17.0 500 0.81 0.935 47 86 81 SLM/BLM 480 V 95 1519 154 460 20.3 600 0.82 0.943 77 ALM 480 V 105 1433 150 500 23.7 700 0.85 0.948 66 1PH8284-1C1 SLM/BLM 400 V 110 1501 240 330 23.7 700 0.85 0.947 106 connection ALM 400 V 125 1492 235 400 27.0 800 0.81 0.952 124 SLM/BLM 480 V 150 1433 230 455 33.7 1,000 0.86 0.957 101 ALM 480 V 155 1346 220 500 37.0 1,100 0.84 0.959 102 1PH8284-1D1 SLM/BLM 400 V 150 1433 315 335 33.7 1,000 0.85 0.958 143 connection ALM 400 V 170 1414 310 400 38.6 1,150 0.82 0.960 157 SLM/BLM 480 V 200 1416 315 460 45.3 1,350 0.83 0.962 151 ALM 480 V 200 1273 290 500 50.3 1,500 0.82 0.963 145 1PH8284-1F1 SLM/BLM 400 V 196 1248 390 345 50.4 1,500 0.87 0.963 162 connection ALM 400 V 225 1228 390 400 58.7 1,750 0.86 96.4 162 SLM/BLM 480 V 255 1218 390 455 67.0 2,000 0.86 0.965 162 ALM 480 V 230 998 500 73.6 2,200 0.83 0.963 163 1PH8284-1H1 BLM 690 V 61 1456 82 555 13.7 400 0.84 0.920 39 Y connection ALM 690 V 77 1471 82 690 17.0 500 0.84 0.932 39 1PH8284-1K1 BLM 690 V 100 1364 118 605 23.7 700 0.85 0.945 53 Y connection ALM 690 V 115 1373 120 690 27.0 800 0.85 0.950 53 1PH8284-1U1 BLM 690 V 143 1366 176 600 33.6 1,000 0.82 0.956 89 Y connection ALM 690 V 164 1362 174 690 38.6 1,150 0.82 0.959 90 1PH8284-1W1 BLM 690 V 186 1184 220 590 50.3 1,500 0.86 0.962 92 Y connection ALM 690 V 217 1184 220 690 58.7 1,750 0.86 0.963 1PH8286-1B1 SLM/BLM 400 V 80 1910 186 325 13.6 400 0.82 0.928 5.20 connection ALM 400 V 100 1909 188 400 17.0 500 0.82 0.939 96 SLM/BLM 480 V 120 1916 188 460 20.3 600 0.85 0.945 88 ALM 480 V 132 1801 184 500 23.7 700 0.87 0.950 76 1PH8286-1C1 SLM/BLM 400 V 138 1883 295 325 23.7 700 0.87 0.949 121 connection ALM 400 V 155 1850 285 385 27.0 800 0.85 0.955 133 SLM/BLM 480 V 185 1767 280 460 33.7 1,000 0.86 0.960 122 ALM 480 V 191 1658 270 500 37.0 1,100 0.85 0.962 120 1PH8286-1D1 SLM/BLM 400 V 182 1738 410 330 33.6 1,000 0.81 0.960 215 connection ALM 400 V 210 1745 410 380 38.6 1,150 0.81 0.962 217 330 m [kg] 1,200 93 50 98 1,400 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 237 Technical data and characteristics 6.1 Induction motors Motor Module Prated Mrated Irated Urated frated nrated [kW] [Nm] [V] [Hz] [rpm] SLM/BLM 480 V 245 1733 410 445 45.3 1,350 0.81 0.963 217 [A] cos J Tth I [kgm2] [min] [A] ALM 480 V 245 1560 380 495 50.3 1,500 0.78 0.963 219 1PH8286-1F1 SLM/BLM 400 V 250 1592 490 345 50.4 1,500 0.89 0.965 182 connection ALM 400 V 270 1474 460 400 58.7 1,750 0.88 0.966 183 SLM/BLM 480 V 310 1481 460 455 67.0 2,000 0.88 0.967 182 ALM 480 V 279 1211 395 500 73.6 2,200 0.85 0.965 183 1PH8286-1H1 BLM 690 V 77 1838 100 555 13.7 400 0.87 0.921 43 Y connection ALM 690 V 96 1834 100 690 17.0 500 0.86 0.934 43 1PH8286-1K1 BLM 690 V 127 1733 158 605 23.6 700 0.81 0.951 83 Y connection ALM 690 V 145 1731 158 690 26.9 800 0.81 0.954 83 1PH8286-1U1 BLM 690 V 176 1681 230 570 33.6 1,000 0.81 0.959 124 Y connection ALM 690 V 203 1686 230 655 38.6 1,150 0.81 0.961 124 1PH8286-1W1 BLM 690 V 224 1426 260 590 50.3 1,500 0.88 0.965 104 Y connection ALM 690 V 261 1424 260 690 58.7 1,750 0.87 0.966 1PH8288-1B1 SLM/BLM 400 V 103 2459 245 325 13.6 400 0.80 0.931 6.30 connection ALM 400 V 130 2481 245 395 17.0 500 0.82 0.941 127 SLM/BLM 480 V 155 2474 245 460 20.3 600 0.84 0.948 121 ALM 480 V 165 2251 230 500 23.7 700 0.86 0.953 104 1PH8288-1C1 SLM/BLM 400 V 166 2265 365 325 23.6 700 0.85 0.953 171 connection ALM 400 V 190 2268 365 370 27.0 800 0.85 0.957 171 SLM/BLM 480 V 230 2197 355 460 33.6 1,000 0.84 0.962 172 ALM 480 V 238 2066 345 500 37.0 1,100 0.83 0.963 168 1PH8288-1D1 SLM/BLM 400 V 226 2158 495 335 33.6 1,000 0.82 0.962 252 connection ALM 400 V 260 2160 495 385 38.6 1,150 0.82 0.964 253 SLM/BLM 480 V 305 2158 495 450 45.3 1,350 0.82 0.965 251 ALM 480 V 305 1942 455 500 50.3 1,500 0.80 0.965 253 1PH8288-1F1 SLM/BLM 400 V 320 2037 620 345 50.4 1,500 0.89 0.966 233 connection ALM 400 V 340 1856 580 400 58.7 1,750 0.88 0.967 233 SLM/BLM 480 V 385 1838 570 455 67.0 2,000 0.88 0.967 232 m [kg] 105 53 136 ALM 480 V 347 1506 495 500 73.6 2,200 0.84 0.966 233 1PH8288-1H1 BLM 690 V 100 2388 130 555 13.7 400 0.87 0.924 55 Y connection ALM 690 V 125 2388 128 690 17.0 500 0.87 0.937 56 1PH8288-1K1 BLM 690 V 162 2210 186 605 23.7 700 0.88 0.949 75 Y connection ALM 690 V 185 2208 184 690 27.0 800 0.88 0.953 76 1PH8288-1U1 BLM 690 V 218 2082 275 580 33.6 1,000 0.82 0.961 145 Y connection ALM 690 V 251 2084 275 665 38.6 1,150 0.82 0.963 145 1PH8288-1W1 BLM 690 V 282 1795 325 590 50.3 1,500 0.88 0.966 133 Y connection ALM 690 V 329 1795 325 690 58.7 1,750 0.87 0.967 134 1,650 1PH8 main motors 238 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors 6.1.1.10 Table 6- 12 Shaft height 280 - forced ventilation (open-circuit ventilation) 1PH8 shaft height 280, degree of protection IP23, forced ventilation, open-circuit ventilation (basic data) Motor Module Prated Mrated Irated Urated frated nrated [kW] [Nm] [V] [Hz] [rpm] [A] cos J Tth I m [kgm2] [min] [A] [kg] 18 101 1,200 1PH8284-1C4 SLM/BLM 400 V 171 2333 355 330 23.9 700 0.91 0.930 4.20 connection ALM 400 V 195 2328 335 400 27.2 800 0.89 0.942 117 SLM/BLM 480 V 235 2244 345 455 33.9 1,000 0.91 0.946 97 ALM 480 V 250 2170 335 500 37.2 1,100 0.90 0.951 98 1PH8284-1D4 SLM/BLM 400 V 243 2321 490 335 33.9 1,000 0.90 0.947 137 connection ALM 400 V 280 2325 475 400 38.9 1,150 0.89 0.953 150 SLM/BLM 480 V 325 2299 475 460 45.5 1,350 0.90 0.957 146 ALM 480 V 325 2069 440 500 50.5 1,500 0.89 0.960 140 1PH8284-1F4 SLM/BLM 400 V 319 2031 620 345 50.6 1,500 0.91 0.957 157 connection ALM 400 V 370 2019 610 400 58.9 1,750 0.91 0.960 158 SLM/BLM 480 V 415 1981 600 455 67.3 2,000 0.91 0.962 157 ALM 480 V 394 1710 520 500 73.8 2,200 0.90 0.964 159 BLM 690 V 162 2210 184 605 23.9 700 0.91 0.927 50 ALM 690 V 185 2208 182 690 27.2 800 0.91 0.934 51 BLM 690 V 236 2254 265 600 33.9 1,000 0.90 0.947 85 ALM 690 V 272 2255 270 690 38.9 1,150 0.89 0.951 86 BLM 690 V 307 1955 345 590 50.6 1,500 0.91 0.956 89 ALM 690 V 359 1959 345 690 58.9 1,750 0.91 0.959 91 1PH8286-1C4 SLM/BLM 400 V 219 2988 455 325 23.9 700 0.92 0.931 5.20 connection ALM 400 V 250 2984 435 385 27.2 800 0.91 0.942 126 SLM/BLM 480 V 310 2961 450 460 33.9 1,000 0.91 0.948 117 ALM 480 V 330 2865 440 500 37.2 1,100 0.91 0.952 115 1PH8286-1D4 SLM/BLM 400 V 309 2951 630 330 33.8 1,000 0.90 0.952 207 connection ALM 400 V 355 2944 630 380 38.8 1,150 0.89 0.956 209 SLM/BLM 480 V 410 2901 620 445 45.5 1,350 0.89 0.960 210 1PH82841K4 Y connection 1PH82841U4 Y connection 1PH82841W4 Y connection 20 115 ALM 480 V 410 2610 560 495 50.4 1,500 0.88 0.963 214 1PH8286-1F4 SLM/BLM 400 V 382 2432 730 345 50.6 1,500 0.92 0.959 177 connection ALM 400 V 445 2429 730 400 58.9 1,750 0.92 0.962 178 SLM/BLM 480 V 500 2387 720 455 67.2 2,000 0.92 0.963 178 ALM 480 V 475 2062 620 500 73.8 2,200 0.91 0.966 180 BLM 690 V 210 2865 235 605 23.8 700 0.90 0.938 79 ALM 690 V 240 2865 235 690 27.2 800 0.90 0.944 79 BLM 690 V 299 2855 355 570 33.8 1,000 0.89 0.952 119 ALM 690 V 344 2860 355 655 38.8 1,150 0.89 0.956 119 BLM 690 V 370 2356 410 590 50.6 1,500 0.92 0.958 101 ALM 690 V 432 2356 410 690 58.9 1,750 0.92 0.961 102 1PH82861K4 Y connection 1PH82861U4 Y connection 1PH82861W4 Y connection 1,400 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 239 Technical data and characteristics 6.1 Induction motors Motor Module Prated Mrated Irated Urated frated nrated [kW] [Nm] [V] [Hz] [rpm] [A] cos J Tth I m [kgm2] [min] [A] [kg] 22 161 1,650 1PH8288-1C4 SLM/BLM 400 V 272 3711 570 325 23.9 700 0.91 0.939 6.30 connection ALM 400 V 310 3701 560 370 27.2 800 0.91 0.945 164 SLM/BLM 480 V 385 3677 560 460 33.9 1,000 0.91 0.953 164 ALM 480 V 405 3516 540 500 37.2 1,100 0.91 0.956 162 1PH8288-1D4 SLM/BLM 400 V 379 3619 760 335 33.8 1,000 0.90 0.955 242 connection ALM 400 V 435 3607 760 385 38.8 1,150 0.90 0.958 244 SLM/BLM 480 V 505 3573 750 450 45.5 1,350 0.90 0.962 243 ALM 480 V 505 3215 680 500 50.4 1,500 0.89 0.965 247 1PH8288-1F4 SLM/BLM 400 V 480 3056 910 345 50.6 1,500 0.92 0.961 229 connection ALM 400 V 560 3055 910 400 58.9 1,750 0.92 0.963 228 SLM/BLM 480 V 630 3009 900 455 67.2 2,000 0.92 0.965 230 ALM 480 V 599 2600 790 500 73.8 2,200 0.91 0.967 230 BLM 690 V 263 3588 295 605 23.9 700 0.92 0.929 71 ALM 690 V 300 3581 290 690 27.3 800 0.92 0.936 72 BLM 690 V 367 3505 425 580 33.8 1,000 0.90 0.954 140 ALM 690 V 422 3504 425 665 38.8 1,150 0.90 0.958 140 BLM 690 V 465 2961 520 590 50.5 1,500 0.92 0.960 130 ALM 690 V 543 2964 510 690 58.9 1,750 0.92 0.963 131 1PH82881K4 Y connection 1PH82881U4 Y connection 1PH82881W4 Y connection 6.1.1.11 Overload factors for intermittent duty types (S6) and short-time duty (S2) The specified overload factors for intermittent duty types (S6) and for short-time duty (S2) are based on the S1 characteristic (continuous operation) of the relevant motor. Table 6- 13 S6/S2 overload factors for forced-ventilated asynchronous motors (IP55) Motor type Overload factors S6 - 60% S6 - 40% S6 - 25% S2 - 30 min 1PH808-10/1 1.20 1.50 1.90 1.20 1PH810-10/1 1.20 1.50 1.90 1.20 1PH813-10/1 1.20 1.50 1.90 1.20 1PH816-10/1 1.20 1.50 1.90 1.20 1PH8184-10/1 1.23 1.47 1.74 1.16 1PH8186-10/1 1.25 1.49 1.79 1.20 1PH8224-10/1 1.23 1.47 1.70 1.48 1PH8226-10/1 1.23 1.47 1.70 1.51 1PH8228-10/1 1.23 1.47 1.70 1.54 1PH8284-10/1 1.23 1.47 1.76 1.46 1PH8286-10/1 1.23 1.47 1.76 1.49 1PH8288-10/1 1.23 1.47 1.76 1.52 1PH8 main motors 240 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 14 S6/S2 overload factors for forced-ventilated asynchronous motors, open-circuit ventilation (IP23) Motor type 6.1.1.12 Table 6- 15 Motor type Overload factors S6 - 60% S6 - 40% S6 - 25% S2 - 30 min 1PH8184-13/4 1.23 1.47 1.74 1.21 1PH8186-13/4 1.25 1.49 1.79 1.25 1PH8224-13/4 1.23 1.47 1.70 1.15 1PH8226-13/4 1.23 1.47 1.70 1.17 1PH8228-13/4 1.23 1.47 1.70 1.20 1PH8284 -14 1.23 1.47 1.76 1.11 1PH8286 -14 1.23 1.47 1.76 1.14 1PH8288 -14 1.23 1.47 1.76 1.16 Shaft height 80 - water-cooled 1PH8 shaft height 80, water cooling (basic data) Supply voltage Prat- Mrate Irated Urat frated nrated ed d [A] ed [Hz] [rpm] [kW] [Nm] [V] cos J Tth I P_cool m [kgm2] [min] [A] [kW] [kg] 0.0064 8 3.6 0.7 36 1.2 44 1PH80831F2 SLM/BLM 400 V 3.5 22 8.9 357 54.5 1,500 0.84 0.784 Y connection ALM 400 V 4.0 22 8.7 416 62.4 1,750 0.82 0.808 4.0 SLM/BLM 480 V 4.6 22 8.7 457 71.0 2,000 0.83 0.839 3.8 ALM 480 V 5.0 22 8.7 500 77.4 2,200 0.82 0.850 3.8 1PH80831G2 SLM/BLM 400 V 4.3 21 12.0 322 70.4 2,000 0.80 0.833 5.9 Y connection ALM 400 V 4.9 20 12.0 362 80.4 2,300 0.80 0.846 5.8 SLM/BLM 480 V 5.6 20 12.0 425 91.8 2,650 0.76 0.862 6.5 ALM 480 V 6.0 20 12.0 450 96.4 2,800 0.75 0.870 6.6 SLM/BLM 400 V 6.7 14 18.0 347 152.9 4,500 0.76 0.877 9.2 ALM 400 V 7.5 14 18.0 383 169.7 5,000 0.76 0.891 9.2 SLM/BLM 480 V 8.2 14 18.0 430 186.1 5,500 0.74 0.909 9.6 ALM 480 V 8.9 14 18.0 460 203.0 6,000 0.75 0.880 SLM/BLM 400 V 4.6 29 13.7 316 53.3 1,500 0.78 0.814 ALM 400 V 5.4 29 13.7 358 61.2 1,750 0.77 0.831 6.8 SLM/BLM 480 V 6.1 29 13.7 402 70.0 2,000 0.79 0.868 6.8 ALM 480 V 6.7 29 13.7 435 76.4 2,200 0.78 0.860 6.7 1PH80871G2 SLM/BLM 400 V 6.1 29 17.5 312 70.3 2,000 0.80 0.843 8.4 Y connection ALM 400 V 7.0 29 17.7 355 80.3 2,300 0.79 0.860 8.6 SLM/BLM 480 V 8.1 29 17.8 400 91.9 2,650 0.80 0.871 8.4 ALM 480 V 8.5 29 17.8 420 97.0 2,800 0.80 0.870 8.5 1PH80871N2 SLM/BLM 400 V 8.5 18 24.0 345 152.5 4,500 0.74 0.891 12.4 Y connection ALM 400 V 9.5 18 24.0 380 169.3 5,000 0.75 0.894 12.3 SLM/BLM 480 V 10.5 18 24.0 420 186.0 5,500 0.74 0.898 12.4 ALM 480 V 11.4 18 24.0 450 202.3 6,000 0.75 0.890 12.3 1PH80831N2 Y connection 1PH80871F2 Y connection 9.3 0.0089 8 7.2 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 241 Technical data and characteristics 6.1 Induction motors Table 6- 16 1PH8 shaft height 80 forced ventilation - Premium Performance (supplementary basic data) Motor type 6.1.1.13 Table 6- 17 Motor type J [kgm2] Tth [min] P_cool [kW] 1PH8081-1T2 Y connection 0.0045 8 1.2 1PH8081-1U2 Y connection 0.0045 8 1.2 1PH8081-1W2 Y connection 0.0045 8 1.2 1PH8081-1V2 Y connection 0.0045 8 1.2 1PH8083-1T2 Y connection 0.0064 8 1.2 1PH8083-1U2 Y connection 0.0064 8 1.2 1PH8087-1U2 Y connection 0.0089 8 1.3 Shaft height 100 - water-cooled 1PH8 shaft height 100, water cooling (basic data) Supply voltage Prat- Mrate Irated Urat frated nrated ed d [A] ed [Hz] [rpm] [kW] [Nm] [V] cos J Tth I P_cool m [kgm2] [min] [A] [kW] [kg] 0.0138 10 6.0 1.3 51 1.8 60 13.3 2.7 74 1PH81011F2 SLM/BLM 400 V 5.0 32 12.8 357 53.1 1500 0.81 0.813 Y connection ALM 400 V 5.8 32 12.8 400 61.7 1750 0.82 0.834 5.4 SLM/BLM 480 V 6.6 32 12.5 450 69.9 2000 0.82 0.858 4.4 ALM 480 V 7.2 31 12.5 480 76.6 2,200 0.80 0.860 6.0 1PH81011G2 SLM/BLM 400 V 6.4 31 16.8 335 69.8 2000 0.81 0.857 7.6 Y connection ALM 400 V 7.3 30 16.8 382 79.7 2300 0.80 0.874 7.8 SLM/BLM 480 V 8.4 30 16.8 435 91.4 2650 0.80 0.888 7.7 ALM 480 V 8.3 28 16.5 448 96.1 2,800 0.76 0.890 7.8 SLM/BLM 400 V 7.1 45 19.7 317 53.0 1500 0.82 0.827 ALM 400 V 8.2 45 19.7 364 61.3 1750 0.82 0.851 8.6 SLM/BLM 480 V 9.4 45 19.7 411 69.7 2000 0.82 0.869 8.5 ALM 480 V 10.3 45 19.7 430 76.8 2,200 0.84 0.860 8.6 SLM/BLM 400 V 9.5 45 23.8 343 69.8 2000 0.82 0.857 10.3 ALM 400 V 10.9 45 23.8 392 79.8 2300 0.82 0.883 10.3 SLM/BLM 480 V 12.5 45 23.5 454 91.2 2650 0.79 0.904 11.3 ALM 480 V 12.8 44 22.5 470 96.2 2,800 0.80 0.890 10.7 SLM/BLM 400 V 10.6 34 30.0 309 102.4 3000 0.80 0.900 13.0 ALM 400 V 11.7 34 30.0 340 112.4 3300 0.80 0.900 13.2 SLM/BLM 480 V 12.7 34 29.7 368 122.5 3600 0.80 0.910 13.0 ALM 480 V 13.0 32 29.0 397 132.4 3,900 0.79 0.900 SLM/BLM 400 V 11.0 70 28.5 340 52.8 1500 0.81 0.843 ALM 400 V 12.5 68 28.5 380 60.6 1750 0.81 0.862 1PH81031F2 Y connection 1PH81031G2 Y connection 1PH81031M2 Y connection 1PH81051F2 0.0172 10 8.6 13.0 0.0252 10 12.1 1PH8 main motors 242 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Motor type Supply voltage Prat- Mrate Irated Urat frated nrated ed d [A] ed [Hz] [rpm] [kW] [Nm] Y connection [V] cos J Tth I P_cool m [kgm2] [min] [A] [kW] SLM/BLM 480 V 14.0 67 27.5 426 69.5 2000 0.82 0.894 11.7 ALM 480 V 15.4 67 27.5 458 76.3 2,200 0.83 0.880 12.0 SLM/BLM 400 V 13.0 62 34.5 326 69.3 2000 0.81 0.879 15.6 ALM 400 V 15.0 62 34.0 370 79.3 2300 0.81 0.891 15.1 SLM/BLM 480 V 17.0 61 33.5 424 90.9 2650 0.81 0.911 15.3 ALM 480 V 18.0 61 33.5 450 96.0 2,800 0.80 0.890 15.6 1PH81051M2 SLM/BLM 400 V 16.8 53 45.0 324 102.3 3000 0.80 0.900 20.3 Y connection ALM 400 V 18.5 54 45.0 355 112.4 3300 0.80 0.910 20.2 SLM/BLM 480 V 20.0 53 45.0 375 122.5 3600 0.81 0.920 18.6 1PH81051G2 Y connection ALM 480 V 21.0 51 43.5 405 132.5 3,900 0.81 0.910 1PH81071F2 SLM/BLM 400 V 14.0 89 43.7 277 53.3 1500 0.83 0.829 Y connection ALM 400 V 15.5 85 42.0 314 61.4 1750 0.83 0.847 17.5 SLM/BLM 480 V 18.0 86 42.6 363 69.7 2000 0.81 0.873 19.1 ALM 480 V 19.8 86 42.6 381 76.3 2,200 0.84 0.880 17.0 1PH81071M2 SLM/BLM 400 V 18.0 57 60.0 264 102.2 3000 0.80 0.900 26.0 Y connection ALM 400 V 20.0 58 60.0 290 112.2 3300 0.80 0.900 26.1 SLM/BLM 480 V 21.0 56 59.0 315 122.1 3600 0.79 0.910 26.1 ALM 480 V 21.6 53 58.0 329 131.9 3,900 0.80 0.900 24.5 cos 6.1.1.14 Table 6- 18 Motor type 18.6 0.0289 10 17.8 3.0 1PH8 shaft height 132, water cooling (basic data) Supply voltage Prat- Mrate Irated Urat frated nrated ed d [A] ed [Hz] [rpm] [V] J Tth I P_cool m [kgm2] [min] [A] [kW] [kg] 0.059 12 9.2 2.6 105 14.2 2.8 123 1PH81311F2 SLM/BLM 400 V 15.0 96 30 380 52.3 1500 0.89 0.883 Y connection ALM 400 V 17.0 93 30 425 60.6 1750 0.89 0.897 8.2 SLM/BLM 480 V 18.5 88 30 460 68.7 2000 0.90 0.912 7.2 ALM 480 V 20.0 87 29 500 75.9 2,200 0.90 0.910 7.2 1PH81311G2 SLM/BLM 400 V 18.0 86 40 352 69.1 2000 0.85 0.908 15.5 Y connection ALM 400 V 20.0 83 39 400 78.4 2300 0.85 0.920 15.4 SLM/BLM 480 V 23.0 83 39 458 90.1 2650 0.85 0.938 15.4 ALM 480 V 24.0 82 39 472 95.2 2,800 0.86 0.920 15.0 1PH81331F2 SLM/BLM 400 V 17.0 108 38 345 51.5 1500 0.86 0.883 Y connection ALM 400 V 19.5 106 38 403 59.9 1750 0.85 0.913 14.9 SLM/BLM 480 V 22.5 107 38 452 68.2 2000 0.86 0.938 14.4 ALM 480 V 24.0 104 37 495 74.8 2,200 0.86 0.930 14.1 SLM/BLM 400 V 22.0 105 52 336 68.2 2000 0.84 0.909 22.2 ALM 400 V 25.0 104 52 373 78.3 2300 0.86 0.923 19.4 SLM/BLM 480 V 28.0 101 50 427 89.9 2650 0.85 0.933 19.5 ALM 480 V 29.0 99 50 450 94.9 2,800 0.85 0.920 19.5 Y connection 83 Shaft height 132 - water-cooled [kW] [Nm] 1PH81331G2 [kg] 0.076 12 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 243 Technical data and characteristics 6.1 Induction motors Motor type Supply voltage Prat- Mrate Irated Urat frated nrated ed d [A] ed [Hz] [rpm] [kW] [Nm] 1PH81351F2 [V] cos J Tth I P_cool m [kgm2] [min] [A] [kW] 0.094 12 20.3 3.3 SLM/BLM 400 V 22.0 140 51 342 51.5 1500 0.85 0.901 ALM 400 V 25.5 139 51 395 59.9 1750 0.85 0.914 20.1 SLM/BLM 480 V 29.0 138 52 448 68.2 2000 0.85 0.931 19.9 ALM 480 V 31.0 135 50 480 74.9 2,200 0.85 0.920 20.0 SLM/BLM 400 V 29.0 138 64 348 68.3 2000 0.86 0.924 23.9 ALM 400 V 31.0 129 61 381 78.3 2300 0.88 0.933 23.3 SLM/BLM 480 V 32.0 115 58 448 89.6 2650 0.84 0.942 23.0 ALM 480 V 33.0 113 57 462 94.7 2,800 0.84 0.920 1PH81371F2 SLM/BLM 400 V 27.0 172 67 315 51.6 1500 0.86 0.900 Y connection ALM 400 V 31.5 172 67 364 59.9 1750 0.86 0.911 24.8 SLM/BLM 480 V 36.0 172 67 415 68.3 2000 0.86 0.928 25.4 ALM 480 V 39.0 169 66 456 74.9 2,200 0.85 0.920 25.5 1PH81381F2 SLM/BLM 400 V 30.0 191 80 289 51.9 1500 0.88 0.882 Y connection ALM 400 V 33.0 180 77 332 60.1 1750 0.87 0.898 27.1 4.2 SLM/BLM 480 V 37.0 177 76 380 68.4 2000 0.86 0.920 28.4 4.2 ALM 480 V 39.0 169 72 410 75.0 2,200 0.86 0.910 27.0 4.2 cos Y connection 1PH81351G2 Y connection 6.1.1.15 Table 6- 19 Motor 23.1 0.109 0.109 12 12 25.3 3.8 27.1 4.2 Module Prat- Mrate Irated Urat frated nrated ed d [A] ed [Hz] [rpm] [V] Tth I P_cool m [kgm2] [min] [A] [kW] [kg] 14 27.4 3.8 37 236 84 328 51.1 1500 0.88 0.916 0.216 Y connection ALM 400 V 43 235 84 380 59.4 1750 0.88 0.924 27.3 4.1 SLM/BLM 480 V 49 234 84 430 67.7 2000 0.88 0.925 26.9 3.6 ALM 480 V 53 230 83 460 74.4 2,200 0.88 0.920 26.5 3.6 1PH81631G2 SLM/BLM 400 V 42 201 93 335 67.6 2000 0.88 0.937 30.8 4.0 Y connection ALM 400 V 48 199 93 382 77.6 2300 0.88 0.939 30.2 4.2 SLM/BLM 480 V 55 198 90 450 89.2 2650 0.86 0.940 33.6 4.1 ALM 480 V 56 191 89 462 94.3 2,800 0.88 0.940 1PH81651F2 SLM/BLM 400 V 46 293 104 330 50.9 1500 0.87 0.930 0.232 Y connection ALM 400 V 53 289 104 374 59.3 1750 0.88 0.935 33.8 4.8 SLM/BLM 480 V 60 287 103 426 67.6 2000 0.88 0.940 34.0 4.8 ALM 480 V 66 287 103 457 74.4 2,200 0.89 0.940 33.0 4.8 SLM/BLM 400 V 53 253 110 352 67.6 2000 0.89 0.938 32.1 4.7 ALM 400 V 60 249 107 410 77.6 2300 0.88 0.946 33.7 4.9 SLM/BLM 480 V 65 234 100 460 89.2 2650 0.89 0.948 31.9 4.8 ALM 480 V 68 232 100 494 94.2 2,800 0.88 0.940 33.5 4.8 SLM/BLM 400 V 52 331 116 332 51.2 1500 0.88 0.936 0.232 ALM 400 V 61 333 116 381 59.5 1750 0.89 0.940 35.2 5.7 SLM/BLM 480 V 68 325 116 426 67.9 2000 0.89 0.941 32.8 5.8 Y connection 160 J SLM/BLM 400 V 1PH81661F2 157 1PH8 SH 160, water cooling (basic data) 1PH81631F2 Y connection 141 Shaft height 160 - water cooling [kW] [Nm] 1PH81651G2 [kg] 229 30.2 4.1 14 14 37.2 4.6 36.7 5.5 264 269 1PH8 main motors 244 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Motor Module Prat- Mrate Irated Urat frated nrated ed d [A] ed [Hz] [rpm] [kW] [Nm] [V] cos J Tth I P_cool m [kgm2] [min] [A] [kW] [kg] ALM 480 V 75 326 116 470 74.5 2,200 0.89 0.940 34.4 5.8 1PH81661G2 SLM/BLM 400 V 64 306 125 376 67.8 2000 0.88 0.937 39.3 5.9 Y connection ALM 400 V 72 299 124 420 77.8 2300 0.89 0.946 35.5 5.9 SLM/BLM 480 V 83 299 125 460 89.6 2650 0.90 0.948 35.7 5.9 ALM 480 V 87 297 124 500 94.5 2,800 0.90 0.950 35.5 5.9 nrated cos 6.1.1.16 Table 6- 20 Motor type Shaft height 180 - water-cooled 1PH8 shaft height 180, water-cooled (basic data) Supply voltage Prat- Mrate Irated Urat ed d [A] ed [kW] [Nm] [V] frated [Hz] [rpm] J Tth I P_cool m [kgm2] [min] [A] [kW] [kg] 0.489 25 28 4.1 340 1PH81841B2 SLM/BLM 400 V 17.0 406 50 271 14.0 400 0.87 0.831 Y connection ALM 400 V 23.0 439 54 335 17.4 500 0.86 0.850 27 5.4 SLM/BLM/ALM 480 V 29.0 462 55 405 20.8 600 0.86 0.869 28 5.5 1PH81841C2 SLM/BLM 400 V 33.0 450 77 320 24.2 700 0.89 0.872 33 6.1 Y connection ALM 400 V 38.0 454 77 365 27.5 800 0.88 0.885 33 6.2 SLM/BLM/ALM 480 V 48.0 458 77 460 34.1 1000 0.86 0.905 34 6.8 1PH81841D2 SLM/BLM 400 V 47.0 449 114 300 34.2 1000 0.88 0.904 45 6.9 Y connection ALM 400 V 54.0 448 112 350 39.2 1150 0.87 0.915 46 6.6 SLM/BLM/ALM 480 V 64.0 453 112 410 45.8 1350 0.87 0.924 46 7.3 1PH81841F2 SLM/BLM 400 V 70.0 446 150 335 51.0 1500 0.87 0.928 66 7.3 Y connection ALM 400 V 82.0 447 150 390 59.3 1750 0.87 0.933 65 8.0 SLM/BLM/ALM 480 V 95.0 454 152 450 67.3 2000 0.85 0.938 68 8.6 SLM/BLM 400 V 95.0 363 196 340 85.2 2500 0.87 0.945 75 7.6 ALM 400 V 102 336 182 395 97.5 2900 0.87 0.945 77 8.3 281 76 8.4 42 5.6 1PH81841L2 Y connection SLM/BLM/ALM 480 V 100 158 460 114.0 3400 0.84 0.944 1PH81861B2 SLM/BLM 400 V 23.0 549 68 268 13.9 400 0.86 0.845 Y connection ALM 400 V 30.0 573 70 335 17.3 500 0.85 0.868 43 5.5 0.652 28 SLM/BLM/ALM 480 V 38.0 605 73 405 20.6 600 0.84 0.883 44 6.3 1PH81861C2 SLM/BLM 400 V 43.0 587 97 330 23.9 700 0.86 0.898 49 6.7 Y connection ALM 400 V 49.0 585 99 360 27.4 800 0.88 0.904 44 6.9 SLM/BLM/ALM 480 V 61.0 583 98 450 34.0 1000 0.87 0.920 44 7.2 1PH81861D2 SLM/BLM 400 V 64.0 611 148 320 34.0 1000 0.85 0.920 78 7.7 Y connection ALM 400 V 74.0 615 148 370 38.9 1150 0.84 0.927 80 7.9 SLM/BLM/ALM 480 V 86.0 608 148 420 45.7 1350 0.86 0.933 73 8.4 1PH81861F2 SLM/BLM 400 V 93.0 592 198 330 51.0 1500 0.87 0.935 85 9.0 Y connection ALM 400 V 111 606 200 385 59.3 1750 0.89 0.939 85 9.9 SLM/BLM/ALM 480 V 126 602 200 445 67.3 2000 0.87 0.943 89 10.6 SLM/BLM 400 V 120 458 250 335 83.9 2500 0.88 0.948 109 9.4 ALM 400 V 135 445 245 385 97.3 2900 0.87 0.948 108 10.3 SLM/BLM/ALM 480 V 121 340 200 455 114 3400 0.81 0.942 110 10.4 1PH81861L2 Y connection 410 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 245 Technical data and characteristics 6.1 Induction motors 6.1.1.17 Table 6- 21 Motor type Shaft height 225 - water-cooled 1PH8 shaft height 225, water cooling (basic data) Supply voltage Prat- Mrated Irated Urat- frated nrated ed [Nm] [A] ed [Hz] [rpm] [kW] [V] cos J Tth I P_cool m [kgm2] [min] [A] [kW] [kg] 1.452 30 610 1PH82241B2 SLM/BLM 400 V 36.0 859 100 268 14.0 400 0.91 0.858 37 6.1 Y connection ALM 400 V 46.0 879 100 335 17.3 500 0.90 0.883 38 6.5 SLM/BLM/ALM 480 V 53.0 844 94 410 20.6 600 0.87 0.908 40 5.9 1PH82241C2 SLM/BLM 400 V 61.0 832 128 340 24.0 700 0.89 0.914 48 6.3 Y connection ALM 400 V 70.0 836 130 380 27.3 800 0.89 0.920 46 6.7 SLM/BLM/ALM 480 V 87.0 831 132 460 34.0 1,000 0.89 0.931 44 7.2 SLM/BLM 400 V 89.0 850 188 335 33.9 1000 0.87 0.937 79 6.7 ALM 400 V 101 839 186 385 38.9 1150 0.86 0.944 79 6.8 SLM/BLM/ALM 480 V 115 813 180 450 45.5 1350 0.86 0.950 79 6.9 1PH82241F2 SLM/BLM 400 V 119 758 240 340 50.6 1500 0.89 0.951 87 7.0 Y connection ALM 400 V 138 753 240 395 58.9 1750 0.88 0.954 87 7.6 SLM/BLM/ALM 480 V 155 740 235 460 67.2 2000 0.86 0.958 90 7.8 SLM/BLM 400 V 153 584 310 340 83.8 2500 0.87 0.961 113 7.2 ALM 400 V 164 540 285 395 97.1 2900 0.88 0.961 114 7.7 SLM/BLM/ALM 480 V 164 461 255 460 114.0 3400 0.84 0.959 113 8.1 1PH82261B2 SLM/BLM 400 V 47.0 1122 130 264 14.0 400 0.90 0.875 49 7.1 Y connection ALM 400 V 59.0 1127 128 330 17.3 500 0.90 0.899 50 7.2 SLM/BLM/ALM 480 V 70.0 1114 122 410 20.5 600 0.88 0.919 55 6.8 1PH82261C2 SLM/BLM 400 V 81.0 1105 184 310 23.9 700 0.88 0.928 79 7.0 Y connection ALM 400 V 93.0 1110 186 350 27.2 800 0.88 0.934 77 7.4 SLM/BLM/ALM 480 V 116 1108 184 440 33.9 1000 0.88 0.944 79 7.8 SLM/BLM 400 V 115 1098 235 340 33.9 1000 0.89 0.938 87 8.6 ALM 400 V 131 1088 230 390 38.9 1150 0.89 0.945 87 8.6 SLM/BLM/ALM 480 V 150 1061 225 460 45.5 1350 0.88 0.951 88 8.8 1PH82261F2 SLM/BLM 400 V 145 923 295 340 50.5 1500 0.87 0.957 119 7.5 Y connection ALM 400 V 169 922 295 390 58.8 1750 0.88 0.895 116 8.3 SLM/BLM/ALM 480 V 191 912 290 450 67.1 2000 0.88 0.961 118 8.9 1PH82261L2 SLM/BLM 400 V 185 707 380 335 83.8 2500 0.87 0.963 151 8.2 Y connection ALM 400 V 204 672 360 390 97.1 2900 0.87 0.960 152 9.3 SLM/BLM/ALM 480 V 199 559 310 460 114.0 3400 0.84 0.958 153 10.0 SLM/BLM 400 V 58.0 1385 154 272 13.9 400 0.90 0.886 62 7.9 ALM 400 V 72.0 1375 150 340 17.2 500 0.90 0.908 63 7.9 SLM/BLM/ALM 480 V 85.0 1353 148 410 20.5 600 0.88 0.923 64 7.9 SLM/BLM 400 V 96.0 1310 210 315 23.9 700 0.90 0.930 82 8.1 ALM 400 V 110 210 360 27.2 800 0.90 0.937 82 8.3 1PH82241D2 Y connection 1PH82241L2 Y connection 1PH82261D2 Y connection 1PH82281B2 Y connection 1PH82281C2 1313 1.895 2.354 32 34 615 740 745 870 1PH8 main motors 246 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Motor type Supply voltage Prat- Mrated Irated Urat- frated nrated ed [Nm] [A] ed [Hz] [rpm] [kW] [V] cos J Tth I P_cool m [kgm2] [min] [A] [kW] Y connection SLM/BLM/ALM 480 V 138 1318 210 450 33.9 1000 0.89 0.946 83 8.9 1PH82281D2 SLM/BLM 400 V 141 1346 280 340 33.9 1000 0.91 0.943 98 9.6 Y connection ALM 400 V 161 1337 280 390 38.9 1150 0.90 0.948 98 10.0 SLM/BLM/ALM 480 V 184 1302 270 460 45.5 1350 0.90 0.954 99 10.2 SLM/BLM 400 V 192 1222 390 340 50.5 1500 0.87 0.959 169 9.4 ALM 400 V 221 1206 390 390 58.8 1750 0.87 0.961 165 10.3 SLM/BLM/ALM 480 V 245 1170 380 450 67.1 2000 0.86 0.963 169 10.9 1PH82281L2 SLM/BLM 400 V 226 863 455 340 83.7 2500 0.87 0.964 181 9.8 Y connection ALM 400 V 237 780 415 395 97.0 2900 0.87 0.963 182 10.5 SLM/BLM/ALM 480 V 237 666 370 460 114.0 3400 0.84 0.959 180 11.7 1PH82281F2 Y connection 6.1.1.18 Table 6- 22 Motor type connection 1PH8 shaft height 280, water-cooled (basic data) Supply voltage Prat- Mrated Irated Urat- frated nrated [Nm] ed [Hz] [rpm] cos ed [A] [V] J Tth I P_cool m [kgm2] [min] [A] [kW] [kg] 30 1280 SLM/BLM 400 V 71.0 1695 170 295 13.8 400 0.89 0.914 4.2 70 7.0 ALM 400 V 89.0 1700 172 365 17.1 500 0.88 0.929 69 7.0 SLM/BLM/ALM 480 V 107 1703 170 440 20.4 600 0.88 0.939 71 7.0 1PH82841C2 SLM/BLM 400 V 123 1678 260 330 23.7 700 0.87 0.945 108 7.0 connection ALM 400 V 141 1683 260 375 27.0 800 0.88 0.950 108 8.0 SLM/BLM/ALM 480 V 176 1681 265 455 33.7 1000 0.88 0.956 102 8.0 1PH82841D2 SLM/BLM 400 V 172 1643 350 335 33.7 1000 0.88 0.957 144 8.0 connection ALM 400 V 198 1644 355 385 38.7 1150 0.87 0.960 144 9.0 SLM/BLM/ALM 480 V 232 1641 355 450 45.4 1350 0.87 0.963 143 9.0 SLM/BLM 400 V 227 1445 445 343 50.4 1500 0.89 0.964 161 9.0 ALM 400 V 265 1446 445 400 58.7 1750 0.89 0.966 161 10.0 SLM/BLM/ALM 480 V 303 1447 445 455 67.0 2000 0.89 0.967 160 11.0 BLM 690 V 68.0 1624 89 555 13.7 400 0.87 0.917 4.2 41 6.0 ALM 690 V 85.0 1624 89 690 17.0 500 0.86 0.931 41 6.0 BLM 690 V 119 1624 136 605 23.7 700 0.88 0.942 54 8.0 ALM 690 V 137 1635 138 690 27.0 800 0.88 0.947 54 8.0 1PH82841F2 connection 1PH82841H2 Y connection 1PH82841K2 Y connection 1PH82841U2 Y connection 1PH82841W2 Y connection 875 Shaft height 280 - water-cooled [kW] 1PH82841B2 [kg] 30 BLM 690 V 167 1595 196 600 33.6 1000 0.86 0.956 89 8.0 ALM 690 V 192 1594 198 690 38.6 1150 0.85 0.959 90 8.0 BLM 690 V 220 1401 250 590 50.4 1500 0.89 0.963 92 9.0 ALM 690 V 257 1401 250 690 58.7 1750 0.89 0.965 92 10.0 1280 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 247 Technical data and characteristics 6.1 Induction motors Motor type Supply voltage Prat- Mrated Irated Urat- frated nrated [Nm] [A] ed [Hz] [rpm] cos ed [kW] 1PH82861B2 connection [V] J Tth I P_cool m [kgm2] [min] [A] [kW] [kg] 33 1490 SLM/BLM 400 V 89.0 2125 210 300 13.7 400 0.89 0.916 5.2 83 9.0 ALM 400 V 111 2120 205 375 17.0 500 0.89 0.931 84 9.0 SLM/BLM/ALM 480 V 133 2117 205 445 20.4 600 0.89 0.940 83 9.0 1PH82861C2 SLM/BLM 400 V 153 2087 320 325 23.7 700 0.89 0.948 123 9.0 connection ALM 400 V 175 2089 320 375 27.0 800 0.88 0.953 126 9.0 SLM/BLM/ALM 480 V 219 2091 325 455 33.7 1000 0.89 0.958 120 10.0 1PH82861D2 SLM/BLM 400 V 214 2044 460 330 33.6 1000 0.85 0.960 215 9.0 connection ALM 400 V 246 2043 455 380 38.6 1150 0.85 0.962 216 10.0 SLM/BLM/ALM 480 V 289 2044 460 445 45.3 1350 0.85 0.964 216 11.0 1PH82861F2 SLM/BLM 400 V 281 1789 540 343 50.4 1500 0.90 0.966 181 11.0 connection ALM 400 V 328 1790 540 400 58.7 1750 0.90 0.967 182 12.0 SLM/BLM/ALM 480 V 375 1791 550 455 67.0 2000 0.90 0.968 180 13.0 1PH82861H2 Y connection 1PH82861K2 Y connection 1PH82861U2 Y connection 1PH82861W2 BLM 690 V 85.0 2029 108 555 13.7 400 0.89 0.917 5.2 ALM 690 V 106 108 690 17.0 500 0.88 0.931 2025 33 45 8.0 45 8.0 BLM 690 V 148 2019 174 605 23.6 700 0.85 0.950 84 8.0 ALM 690 V 170 2029 176 690 27.0 800 0.85 0.954 84 8.0 BLM 690 V 208 1986 260 570 33.6 1000 0.85 0.959 123 9.0 ALM 690 V 239 1985 260 655 38.6 1150 0.85 0.962 123 10.0 BLM 690 V 273 1738 310 590 50.4 1500 0.90 0.965 104 11.0 ALM 690 V 318 1735 305 690 58.7 1750 0.90 0.967 104 12.0 SLM/BLM 400 V 109 2602 260 295 13.7 400 0.89 0.925 6.3 110 9.0 ALM 400 V 136 2598 260 365 17.0 500 0.88 0.938 109 9.0 SLM/BLM/ALM 480 V 164 2610 260 440 20.3 600 0.88 0.946 111 10.0 1PH82881C2 SLM/BLM 400 V 188 2565 400 324 23.6 700 0.88 0.952 172 10.0 connection ALM 400 V 215 2567 405 370 27.0 800 0.87 0.956 172 10.0 SLM/BLM/ALM 480 V 269 2569 405 460 33.6 1000 0.87 0.961 171 11.0 1PH82881D2 SLM/BLM 400 V 264 2521 550 335 33.6 1000 0.86 0.962 251 11.0 connection ALM 400 V 304 2525 550 385 38.6 1150 0.86 0.964 251 12.0 SLM/BLM/ALM 480 V 357 2525 550 450 45.3 1350 0.86 0.966 249 13.0 1PH82881F2 SLM/BLM 400 V 345 2197 660 345 50.3 1500 0.90 0.967 234 13.0 connection ALM 400 V 403 2199 670 400 58.7 1750 0.90 0.968 232 14.0 SLM/BLM/ALM 480 V 460 2197 670 455 67.0 2000 0.90 0.969 230 16.0 BLM 690 V 105 2507 134 555 13.7 400 0.88 0.923 6.3 58 9.0 ALM 690 V 131 2502 134 690 17.0 500 0.88 0.936 58 9.0 Y connection 1PH82881B2 connection 1PH82881H2 Y connection 1PH82881K2 Y connection 1PH82881U2 Y connection 35 35 BLM 690 V 182 2483 205 605 23.7 700 0.90 0.946 77 11.0 ALM 690 V 209 2495 205 690 27.0 800 0.90 0.951 77 12.0 BLM 690 V 256 2445 310 580 33.6 1000 0.86 0.961 145 11.0 ALM 690 V 295 2450 310 665 38.6 1150 0.86 0.963 144 12.0 1490 1750 1750 1PH8 main motors 248 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Motor type Supply voltage Prat- Mrated Irated Urat- frated nrated ed [Nm] ed [Hz] [rpm] [kW] 1PH82881W2 Y connection [A] [V] cos J Tth I P_cool m [kgm2] [min] [A] [kW] BLM 690 V 335 2133 375 590 50.3 1500 0.90 0.966 132 13.0 ALM 690 V 391 2134 375 690 58.7 1750 0.90 0.968 133 14.0 6.1.1.19 [kg] Overload factors for intermittent duty types (S6) and short-time duty (S2) The specified overload factors for intermittent duty types (S6) and for short-time duty (S2) are based on the S1 characteristic (continuous operation) of the relevant motor. Table 6- 23 S6/S2 overload factors for water-cooled asynchronous motors Motor type Overload factors S6 - 60% S6 - 40% S6 - 25% S2 - 30 min 1PH808-12 1.20 1.40 1.70 1.00 1PH810-12 1.20 1.40 1.70 1.00 1PH813-12 1.20 1.40 1.70 1.00 1PH816-12 1.20 1.47 1.70 1.00 1PH8184-12 1.23 1.47 1.70 1.20 1PH8186-12 1.23 1.47 1.70 1.23 1PH8224-12 1.23 1.47 1.70 1.26 1PH8226-12 1.23 1.47 1.70 1.28 1PH8228-12 1.23 1.47 1.70 1.30 1PH8284 -12 1.23 1.47 1.70 1.26 1PH8286 -12 1.23 1.47 1.70 1.29 1PH8288 -12 1.23 1.47 1.70 1.31 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 249 Technical data and characteristics 6.1 Induction motors 6.1.2 Characteristics forced ventilation 6.1.2.1 Shaft height 80 - forced ventilation Table 6- 24 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8083-F nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,500 2.8 18 7.5 10,000 12,000 - 5,000 4,700 34 18 21 8 1PH8 main motors 250 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 25 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8083-F nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 3.3 18 7.5 10,000 12,000 - 5,000 5,200 34 1,500 2.8 18 7.5 10,000 Imax [A] M0 [Nm] I0 [A] 18 21 8 6,200 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 251 Technical data and characteristics 6.1 Induction motors Table 6- 26 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8083-F nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 2,000 3.7 18 7.6 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 10,000 12,000 - 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 5,550 34 18 21 8 1PH8 main motors 252 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 27 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8083-F nN PN MN IN [rpm] [kW] [Nm] [A] 2,200 4.1 18 7.6 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 10,000 12,000 -- 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 6,300 34 18 21 8 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 253 Technical data and characteristics 6.1 Induction motors Table 6- 28 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8083-G, nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,000 3.7 18 11.6 10,000 15,000 17,000 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 9,200 45 24 21 12 1PH8 main motors 254 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 29 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8083-G, nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 2,300 4.1 17 11.3 10,000 15,000 17,000 5,000 10,550 45 2,000 3.7 18 11.6 Imax [A] M0 [Nm] I0 [A] 24 21 12 11,350 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 255 Technical data and characteristics 6.1 Induction motors Table 6- 30 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8083-G, nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,650 4.6 17 11.2 10,000 15,000 17,000 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 11,150 45 24 21 12 1PH8 main motors 256 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 31 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8083-G, nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,800 4.8 16 11.3 10,000 15,000 17,000 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 12,950 45 24 21 12 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 257 Technical data and characteristics 6.1 Induction motors Table 6- 32 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8083-M, nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 3,000 4.1 13 13.6 10,000 15,000 20,000 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 14,650 45 36 21 17 1PH8 main motors 258 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 33 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8083-M, nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 3,300 4.5 13 13.5 10,000 15,000 20,000 5,000 16,500 45 3,000 4.1 13 13.6 Imax [A] M0 [Nm] I0 [A] 36 21 17 17,300 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 259 Technical data and characteristics 6.1 Induction motors Table 6- 34 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8083-M, nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 3,600 4.9 13 14 10,000 15,000 20,000 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 17,650 45 36 21 17 1PH8 main motors 260 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 35 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8083-M, nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 3,900 5.3 13 14 10,000 15,000 20,000 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 19,650 45 36 21 17 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 261 Technical data and characteristics 6.1 Induction motors Table 6- 36 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8083-N, nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 4,500 4.8 10 17 10,000 15,000 20,000 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 20,000 45 46 19 23 1PH8 main motors 262 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 37 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8083-N, nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 5,000 5.3 10 17 10,000 15,000 20,000 5,000 20,000 45 4,500 4.8 10 17 Imax [A] M0 [Nm] I0 [A] 46 19 23 20,000 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 263 Technical data and characteristics 6.1 Induction motors Table 6- 38 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8083-N, nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 5,500 5.5 10 16.5 10,000 15,000 20,000 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 20,000 45 46 19 23 1PH8 main motors 264 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 39 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8083-N, nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 6,000 5 8 15.9 10,000 15,000 20,000 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 20,000 45 46 19 23 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 265 Technical data and characteristics 6.1 Induction motors Table 6- 40 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8087-F nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 1,500 3.7 24 10 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 10,000 14,000 - 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 5,200 49 20 27 11 1PH8 main motors 266 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 41 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8087-F nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 4.3 23 10 10,000 14,000 - 5,000 5,850 49 1,500 3.7 24 10 Imax [A] M0 [Nm] I0 [A] 20 27 11 6,750 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 267 Technical data and characteristics 6.1 Induction motors Table 6- 42 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8087-F nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 2,000 4.9 23 10 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 10,000 14,000 - 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 6,100 49 20 27 11 1PH8 main motors 268 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 43 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8087-F nN PN MN IN [rpm] [kW] [Nm] [A] 2,200 5.3 23 10 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 10,000 14,000 -- 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 7,100 49 20 27 11 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 269 Technical data and characteristics 6.1 Induction motors Table 6- 44 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8087-G, nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,000 4.9 23 14.1 10,000 15,000 18,000 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 8,400 63 31 27 15 1PH8 main motors 270 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 45 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8087-G, nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 2,300 5.4 22 13.7 10,000 15,000 18,000 5,000 9,650 63 2,000 4.9 23 14.1 Imax [A] M0 [Nm] I0 [A] 31 27 15 10,450 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 271 Technical data and characteristics 6.1 Induction motors Table 6- 46 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8087-G, nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,650 6 22 13.6 10,000 15,000 18,000 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 10,300 63 31 27 15 1PH8 main motors 272 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 47 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8087-G, nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,800 6.3 21 13.5 10,000 15,000 18,000 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 12,000 63 31 27 15 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 273 Technical data and characteristics 6.1 Induction motors Table 6- 48 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8087-M, nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 3,000 4.8 15 17.3 10,000 15,000 20,000 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 17,200 65 46 27 23 1PH8 main motors 274 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 49 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8087-M, nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 3,300 5.2 15 17.1 10,000 15,000 20,000 5,000 19,400 65 3,000 4.8 15 17.3 Imax [A] M0 [Nm] I0 [A] 46 27 23 20,000 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 275 Technical data and characteristics 6.1 Induction motors Table 6- 50 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8087-M, nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 3,600 5.7 15 17.1 10,000 15,000 20,000 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 20,000 65 46 27 23 1PH8 main motors 276 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 51 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8087-M, nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 3,900 6 15 17.1 10,000 15,000 20,000 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 20,000 65 46 27 23 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 277 Technical data and characteristics 6.1 Induction motors Table 6- 52 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8087-N, nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 4,500 5.8 12 19.5 10,000 15,000 20,000 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 20,000 65 66 25 28 1PH8 main motors 278 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 53 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8087-N, nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 5,000 6.5 12 19.5 10,000 15,000 20,000 5,000 20,000 65 4,500 5.8 12 19.5 Imax [A] M0 [Nm] I0 [A] 66 25 28 20,000 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 279 Technical data and characteristics 6.1 Induction motors Table 6- 54 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8087-N, nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 5,500 6.9 12 19 10,000 15,000 20,000 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 20,000 65 66 25 28 1PH8 main motors 280 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 55 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8087-N, nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 6,000 7 11 19 10,000 15,000 20,000 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 20,000 65 66 25 28 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 281 Technical data and characteristics 6.1 Induction motors 6.1.2.2 Shaft height 80 - forced ventilation - Premium Performance Note on symbols in the characteristic curves Note Symbols of the characteristic curves for 1PH808 Premium Performance You will find the explanation of the symbols for these motors in Chapter "Configuration for 1PH808 Premium Performance (Page 223)." 1PH8 main motors 282 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 56 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8081-U nN PN MN IN [rpm] [kW] [Nm] [A] 9,000 2.8 3 12.2 n2 nmax Imax1 Imax2 Imax3 Mmax1 Mmax2 Mmax3 fcycle [rpm] [rpm] [A] [A] [A] [Nm] [Nm] [Nm] [kHz] 15,000 24,000 43 54 60 16 19 20 4 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 283 Technical data and characteristics 6.1 Induction motors Table 6- 57 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8081-U nN PN MN IN [rpm] [kW] [Nm] [A] 9,000 2.8 3 12.2 n2 nmax Imax1 Imax2 Imax3 Mmax1 Mmax2 Mmax3 fcycle [rpm] [rpm] [A] [A] [A] [Nm] [Nm] [Nm] [kHz] 15,000 24,000 43 54 60 16 19 20 4 1PH8 main motors 284 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 58 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8081-U nN PN MN IN [rpm] [kW] [Nm] [A] 10,000 3 2.9 12.2 n2 nmax Imax1 Imax2 Imax3 Mmax1 Mmax2 Mmax3 fcycle [rpm] [rpm] [A] [A] [A] [Nm] [Nm] [Nm] [kHz] 16,000 24,000 43 54 60 16 19 20 4 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 285 Technical data and characteristics 6.1 Induction motors Table 6- 59 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8081-U nN PN MN IN [rpm] [kW] [Nm] [A] 10,000 3 2.9 12.2 n2 nmax Imax1 Imax2 Imax3 Mmax1 Mmax2 Mmax3 fcycle [rpm] [rpm] [A] [A] [A] [Nm] [Nm] [Nm] [kHz] 16,000 24,000 43 54 60 16 19 20 4 1PH8 main motors 286 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 60 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8081-V nN PN MN IN [rpm] [kW] [Nm] [A] 9,000 3.5 3.7 15.5 n2 nmax Imax1 Imax2 Imax3 Mmax1 Mmax2 Mmax3 fcycle [rpm] [rpm] [A] [A] [A] [Nm] [Nm] [Nm] [kHz] 15,000 24,000 33 51 60 13 20 24 8 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 287 Technical data and characteristics 6.1 Induction motors Table 6- 61 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8081-V nN PN MN IN [rpm] [kW] [Nm] [A] 9,000 3.5 3.7 15.5 n2 nmax Imax1 Imax2 Imax3 Mmax1 Mmax2 Mmax3 fcycle [rpm] [rpm] [A] [A] [A] [Nm] [Nm] [Nm] [kHz] 15,000 24,000 33 51 60 13 20 24 8 1PH8 main motors 288 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 62 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8081-V nN PN MN IN [rpm] [kW] [Nm] [A] 10,000 3.8 3.6 15.5 n2 nmax Imax1 Imax2 Imax3 Mmax1 Mmax2 Mmax3 fcycle [rpm] [rpm] [A] [A] [A] [Nm] [Nm] [Nm] [kHz] 16,000 24,000 33 51 60 13 20 24 8 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 289 Technical data and characteristics 6.1 Induction motors Table 6- 63 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8081-V nN PN MN IN [rpm] [kW] [Nm] [A] 10,000 3.8 3.6 15.5 n2 nmax Imax1 Imax2 Imax3 Mmax1 Mmax2 Mmax3 fcycle [rpm] [rpm] [A] [A] [A] [Nm] [Nm] [Nm] [kHz] 16,000 24,000 33 51 60 13 20 24 8 1PH8 main motors 290 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 64 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8081-W nN PN MN IN [rpm] [kW] [Nm] [A] 9,000 2.8 3 12.2 n2 nmax Imax1 Imax2 Imax3 Mmax1 Mmax2 Mmax3 fcycle [rpm] [rpm] [A] [A] [A] [Nm] [Nm] [Nm] [kHz] 15,000 24,000 33 51 60 11 18 20 8 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 291 Technical data and characteristics 6.1 Induction motors Table 6- 65 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8081-W nN PN MN IN [rpm] [kW] [Nm] [A] 9,000 2.8 3 12.2 n2 nmax Imax1 Imax2 Imax3 Mmax1 Mmax2 Mmax3 fcycle [rpm] [rpm] [A] [A] [A] [Nm] [Nm] [Nm] [kHz] 15,000 24,000 33 51 60 11 18 20 8 1PH8 main motors 292 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 66 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8081-W nN PN MN IN [rpm] [kW] [Nm] [A] 10,000 3.0 2.9 12.2 n2 nmax Imax1 Imax2 Imax3 Mmax1 Mmax2 Mmax3 fcycle [rpm] [rpm] [A] [A] [A] [Nm] [Nm] [Nm] [kHz] 16,000 24,000 33 51 60 11 18 20 8 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 293 Technical data and characteristics 6.1 Induction motors Table 6- 67 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8081-W nN PN MN IN [rpm] [kW] [Nm] [A] 10,000 3.0 2.9 12.2 n2 nmax Imax1 Imax2 Imax3 Mmax1 Mmax2 Mmax3 fcycle [rpm] [rpm] [A] [A] [A] [Nm] [Nm] [Nm] [kHz] 16,000 24,000 33 51 60 11 18 20 8 1PH8 main motors 294 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 68 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8083-V nN PN MN IN [rpm] [kW] [Nm] [A] 12,000 4.5 3.6 15.2 n2 nmax Imax1 Imax2 Imax3 Mmax1 Mmax2 Mmax3 fcycle [rpm] [rpm] [A] [A] [A] [Nm] [Nm] [Nm] [kHz] 15,000 24,000 60 68 -- 18 20 -- 8 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 295 Technical data and characteristics 6.1 Induction motors Table 6- 69 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8083-V nN PN MN IN [rpm] [kW] [Nm] [A] 12,000 4.5 3.6 15.2 n2 nmax Imax1 Imax2 Imax3 Mmax1 Mmax2 Mmax3 fcycle [rpm] [rpm] [A] [A] [A] [Nm] [Nm] [Nm] [kHz] 15,000 24,000 60 68 -- 18 20 -- 8 1PH8 main motors 296 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 70 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8083-V nN PN MN IN [rpm] [kW] [Nm] [A] 13,000 4.8 3.5 15.2 n2 nmax Imax1 Imax2 Imax3 Mmax1 Mmax2 Mmax3 fcycle [rpm] [rpm] [A] [A] [A] [Nm] [Nm] [Nm] [kHz] 16,000 24,000 60 68 -- 18 20 -- 8 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 297 Technical data and characteristics 6.1 Induction motors Table 6- 71 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8083-V nN PN MN IN [rpm] [kW] [Nm] [A] 13,000 4.8 3.5 15.2 n2 nmax Imax1 Imax2 Imax3 Mmax1 Mmax2 Mmax3 fcycle [rpm] [rpm] [A] [A] [A] [Nm] [Nm] [Nm] [kHz] 16,000 24,000 60 68 -- 18 20 -- 8 1PH8 main motors 298 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 72 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8083-W nN PN MN IN [rpm] [kW] [Nm] [A] 5,200 4.5 8.3 15.2 n2 nmax Imax1 Imax2 Imax3 Mmax1 Mmax2 Mmax3 fcycle [rpm] [rpm] [A] [A] [A] [Nm] [Nm] [Nm] [kHz] 15,000 24,000 60 68 -- 44 50 -- 8 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 299 Technical data and characteristics 6.1 Induction motors Table 6- 73 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8083-W nN PN MN IN [rpm] [kW] [Nm] [A] 5,200 4.5 8.3 15.2 n2 nmax Imax1 Imax2 Imax3 Mmax1 Mmax2 Mmax3 fcycle [rpm] [rpm] [A] [A] [A] [Nm] [Nm] [Nm] [kHz] 15,000 24,000 60 68 -- 44 50 -- 8 1PH8 main motors 300 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 74 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8083-W nN PN MN IN [rpm] [kW] [Nm] [A] 5,600 4.8 8.2 15.2 n2 nmax Imax1 Imax2 Imax3 Mmax1 Mmax2 Mmax3 fcycle [rpm] [rpm] [A] [A] [A] [Nm] [Nm] [Nm] [kHz] 16,000 24,000 60 68 -- 44 50 -- 8 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 301 Technical data and characteristics 6.1 Induction motors Table 6- 75 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8083-W nN PN MN IN [rpm] [kW] [Nm] [A] 5,600 4.8 8.2 15.2 n2 nmax Imax1 Imax2 Imax3 Mmax1 Mmax2 Mmax3 fcycle [rpm] [rpm] [A] [A] [A] [Nm] [Nm] [Nm] [kHz] 16,000 24,000 60 68 -- 44 50 -- 8 1PH8 main motors 302 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 76 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8087-V nN PN MN IN [rpm] [kW] [Nm] [A] 12,000 6.5 5.2 19.0 n2 nmax Imax1 Imax2 Imax3 Mmax1 Mmax2 Mmax3 fcycle [rpm] [rpm] [A] [A] [A] [Nm] [Nm] [Nm] [kHz] 18,000 24,000 60 68 -- 18 19 -- 8 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 303 Technical data and characteristics 6.1 Induction motors Table 6- 77 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8087-V nN PN MN IN [rpm] [kW] [Nm] [A] 12,000 6.5 5.2 19.0 n2 nmax Imax1 Imax2 Imax3 Mmax1 Mmax2 Mmax3 fcycle [rpm] [rpm] [A] [A] [A] [Nm] [Nm] [Nm] [kHz] 18,000 24,000 60 68 -- 18 19 -- 8 1PH8 main motors 304 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 78 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8087-V nN PN MN IN [rpm] [kW] [Nm] [A] 13,000 7.0 5.1 19.0 n2 nmax Imax1 Imax2 Imax3 Mmax1 Mmax2 Mmax3 fcycle [rpm] [rpm] [A] [A] [A] [Nm] [Nm] [Nm] [kHz] 19,000 24,000 60 68 -- 18 19 -- 8 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 305 Technical data and characteristics 6.1 Induction motors Table 6- 79 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8087-V nN PN MN IN [rpm] [kW] [Nm] [A] 13,000 7.0 5.1 19.0 n2 nmax Imax1 Imax2 Imax3 Mmax1 Mmax2 Mmax3 fcycle [rpm] [rpm] [A] [A] [A] [Nm] [Nm] [Nm] [kHz] 16,000 24,000 60 68 -- 18 19 -- 8 1PH8 main motors 306 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors 6.1.2.3 Table 6- 80 Shaft height 100 - forced ventilation SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8101-F nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 1,500 3.7 24 12.5 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 9,000 12,000 - 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 5,000 60 32 29 14 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 307 Technical data and characteristics 6.1 Induction motors Table 6- 81 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8101-F nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 4.3 23 12.5 9,000 12,000 - 5,000 5,000 60 1,500 3.7 24 12.5 Imax [A] M0 [Nm] I0 [A] 32 29 14 8,350 1PH8 main motors 308 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 82 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8101-F nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 2,000 4.7 22 12.5 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 9,000 12,000 - 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 7,500 60 32 29 14 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 309 Technical data and characteristics 6.1 Induction motors Table 6- 83 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8101-F nN PN MN IN [rpm] [kW] [Nm] [A] 2,200 5.1 22 12.5 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 9,000 12,000 -- 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 7,500 60 32 29 14 1PH8 main motors 310 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 84 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8101-S, connection nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 4,000 3.7 9 13.5 9,000 12,000 18,000 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 10,500 40 60 19 20 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 311 Technical data and characteristics 6.1 Induction motors Table 6- 85 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8101-S, connection nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 5,000 4.9 9 13.5 9,000 12,000 18,000 5,000 10,000 40 4,000 3.7 9 13.5 Imax [A] M0 [Nm] I0 [A] 60 19 20 13,000 1PH8 main motors 312 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 86 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8101-S, connection nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 6,000 6.2 10 13 9,000 12,000 18,000 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 9,500 40 60 19 20 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 313 Technical data and characteristics 6.1 Induction motors Table 6- 87 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8101-S, connection nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 7,000 7.2 10 13 9,000 12,000 18,000 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 10,000 40 60 19 20 1PH8 main motors 314 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 88 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8101-S, Y connection nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 1,500 3.7 24 13.2 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 9,000 12,000 - 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 9,100 60 34 29 15 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 315 Technical data and characteristics 6.1 Induction motors Table 6- 89 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8101-S, Y connection nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 2,000 4.9 23 13.2 9,000 12,000 - 5,000 8,950 60 1,500 3.7 24 13.2 Imax [A] M0 [Nm] I0 [A] 34 29 15 11,000 1PH8 main motors 316 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 90 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8101-S, Y connection nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 2,500 6.2 24 13.2 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 9,000 12,000 - 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 8,500 60 34 29 15 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 317 Technical data and characteristics 6.1 Induction motors Table 6- 91 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8101-S, Y connection nN PN MN IN [rpm] [kW] [Nm] [A] 3,000 7.4 24 13.2 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 9,000 12,000 -- 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 8,900 60 34 29 15 1PH8 main motors 318 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 92 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8103-D nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 1,000 3.7 35 10 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 9,000 12,000 - 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,550 60 34 38 11 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 319 Technical data and characteristics 6.1 Induction motors Table 6- 93 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8103-D nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,150 4.3 36 10 9,000 12,000 - 5,000 2,450 60 1,000 3.7 35 10 Imax [A] M0 [Nm] I0 [A] 34 38 11 3,800 1PH8 main motors 320 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 94 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8103-D nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 1,350 4.7 33 9.7 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 9,000 12,000 - 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,500 60 34 38 11 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 321 Technical data and characteristics 6.1 Induction motors Table 6- 95 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8103-D nN PN MN IN [rpm] [kW] [Nm] [A] 1,500 5.2 33 9.7 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 9,000 12,000 -- 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,500 60 34 38 11 1PH8 main motors 322 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 96 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8103-F nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 1,500 5.5 35 13.5 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 9,000 12,000 - 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,200 60 23 38 14 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 323 Technical data and characteristics 6.1 Induction motors Table 6- 97 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8103-F nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 6.3 34 13.1 9,000 12,000 - 5,000 4,000 60 1,500 5.5 35 13.5 Imax [A] M0 [Nm] I0 [A] 23 38 14 5,200 1PH8 main motors 324 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 98 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8103-F nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 2,000 7 33 12.7 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 9,000 12,000 - 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,100 60 23 38 14 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 325 Technical data and characteristics 6.1 Induction motors Table 6- 99 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8103-F nN PN MN IN [rpm] [kW] [Nm] [A] 2,200 7.7 33 12.7 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 9,000 12,000 -- 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,100 60 23 38 14 1PH8 main motors 326 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 100 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8103-G nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 2,000 7.0 33 17.5 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 9,000 12,000 - 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 6,000 77 42 38 19 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 327 Technical data and characteristics 6.1 Induction motors Table 6- 101 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8103-G nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 2,300 7.5 31 17 9,000 12,000 - 5,000 6,000 77 2,000 7 33 17.5 Imax [A] M0 [Nm] I0 [A] 42 38 19 7,200 1PH8 main motors 328 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 102 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8103-G nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 2,650 8 29 16 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 9,000 12,000 - 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 7,500 77 42 38 19 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 329 Technical data and characteristics 6.1 Induction motors Table 6- 103 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8103-G nN PN MN IN [rpm] [kW] [Nm] [A] 2,800 8.5 29 16 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 9,000 12,000 -- 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 7,000 77 42 38 19 1PH8 main motors 330 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 104 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8103-M nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 3,000 8.4 27 25.7 9,000 12,000 18,000 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 14,250 100 93 38 31 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 331 Technical data and characteristics 6.1 Induction motors Table 6- 105 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8103-M nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 3,300 9.3 27 25.7 9,000 12,000 18,000 5,000 16,000 100 3,000 8.4 27 25.7 Imax [A] M0 [Nm] I0 [A] 93 38 31 17,100 1PH8 main motors 332 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 106 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8103-M nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 3,600 10 27 25.4 9,000 12,000 18,000 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 17,650 100 93 38 31 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 333 Technical data and characteristics 6.1 Induction motors Table 6- 107 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8103-M nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 3,900 10.8 26 25 9,000 12,000 18,000 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 13,000 100 93 38 31 1PH8 main motors 334 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 108 SINAMICS, 3-ph. 400 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8105-F nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 1,500 7 45 17.5 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 9,000 12,000 - 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 5,250 103 41 52 20 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 335 Technical data and characteristics 6.1 Induction motors Table 6- 109 SINAMICS, 3-ph. 400 V AC, Active Line Module, (ALM), 1PH8105-F nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 8 44 17.5 9,000 12,000 - 5,000 5,900 103 1,500 7 45 17.5 Imax [A] M0 [Nm] I0 [A] 41 52 20 6,700 1PH8 main motors 336 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 110 SINAMICS, 3-ph. 480 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8105-F nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 2,000 9 43 17 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 9,000 12,000 - 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 6,250 103 41 52 20 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 337 Technical data and characteristics 6.1 Induction motors Table 6- 111 SINAMICS, 3-ph. 480 V AC, Active Line Module, (ALM), 1PH8105-F nN PN MN IN [rpm] [kW] [Nm] [A] 2,200 9.9 43 17 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 9,000 12,000 -- 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 7,000 103 41 52 20 1PH8 main motors 338 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 112 SINAMICS, 3-ph. 400 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8105-S, connection nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 4,000 7.5 18 24 9,000 12,000 18,000 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 10,000 65 86 36 35 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 339 Technical data and characteristics 6.1 Induction motors Table 6- 113 SINAMICS, 3-ph. 400 V AC, Active Line Module, (ALM), 1PH8105-S, connection nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 5,000 9.3 18 24 9,000 12,000 18,000 5,000 10,000 65 4,000 7.5 18 24 Imax [A] M0 [Nm] I0 [A] 86 36 34 11,500 1PH8 main motors 340 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 114 SINAMICS, 3-ph. 480 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8105-S, connection nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 6,000 11.2 18 22 9,000 12,000 18,000 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 10,000 65 86 36 35 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 341 Technical data and characteristics 6.1 Induction motors Table 6- 115 SINAMICS, 3-ph. 480 V AC, Active Line Module, (ALM), 1PH8105-S, connection nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 7,000 13 18 22 9,000 12,000 18,000 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 10,000 65 86 36 35 1PH8 main motors 342 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 116 SINAMICS, 3-ph. 400 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8105-S, Y connection nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 1,500 7.5 48 23 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 9,000 12,000 - 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 7,900 100 46 55 25 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 343 Technical data and characteristics 6.1 Induction motors Table 6- 117 SINAMICS, 3-ph. 400 V AC, Active Line Module, (ALM), 1PH8105-S, Y connection nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 2,000 10 48 23 9,000 12,000 - 5,000 7,650 100 1,500 7.5 48 23 Imax [A] M0 [Nm] I0 [A] 46 55 25 9,800 1PH8 main motors 344 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 118 SINAMICS, 3-ph. 480 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8105-S, Y connection nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 2,500 12.5 48 23 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 9,000 12,000 - 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 7,300 100 46 55 25 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 345 Technical data and characteristics 6.1 Induction motors Table 6- 119 SINAMICS, 3-ph. 480 V AC, Active Line Module, (ALM), 1PH8105-S, Y connection nN PN MN IN [rpm] [kW] [Nm] [A] 3,000 14.5 46 22.8 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 9,000 12,000 -- 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 7,400 100 46 55 25 1PH8 main motors 346 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 120 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8107-B nN PN MN IN nmax1 nmax2 nmax3 [rpm] [kW] 400 2.5 nmax, Br [Nm] [A] [rpm] [rpm] [rpm] [rpm] 60 8.8 - - - 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,500 100 15 62 9 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 347 Technical data and characteristics 6.1 Induction motors Table 6- 121 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8107-B nN PN MN IN nmax1 nmax2 nmax3 [rpm] [kW] 500 3.2 400 2.5 nmax, Br [Nm] [A] [rpm] [rpm] [rpm] [rpm] 61 8.8 - - - 5,000 60 8.8 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,500 100 15 62 9 2,000 1PH8 main motors 348 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 122 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8107-B nN PN MN IN nmax1 nmax2 nmax3 [rpm] [kW] 600 3.8 nmax, Br [Nm] [A] [rpm] [rpm] [rpm] [rpm] 60 8.8 - - - 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,500 100 15 62 9 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 349 Technical data and characteristics 6.1 Induction motors Table 6- 123 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8107-B nN PN MN IN nmax1 nmax2 nmax3 [rpm] [kW] 700 4.4 nmax, Br [Nm] [A] [rpm] [rpm] [rpm] [rpm] 60 8.7 -- -- -- 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,500 100 15 62 9 1PH8 main motors 350 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 124 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8107-D nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 1,000 6.3 60 17.5 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 9,000 12,000 - 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,300 135 40 63 25 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 351 Technical data and characteristics 6.1 Induction motors Table 6- 125 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8107-D nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,150 7.2 60 17.5 9,000 12,000 - 5,000 4,750 135 1,000 6.3 60 17.5 Imax [A] M0 [Nm] I0 [A] 40 63 25 5,450 1PH8 main motors 352 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 126 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8107-D nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 1,350 8 57 17 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 9,000 12,000 - 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 5,045 135 40 63 25 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 353 Technical data and characteristics 6.1 Induction motors Table 6- 127 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8107-D nN PN MN IN [rpm] [kW] [Nm] [A] 1,500 8.8 56 17 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 9,000 12,000 -- 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 5,750 135 40 63 25 1PH8 main motors 354 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 128 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8107-F nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 1,500 9 57 23.5 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 9,000 12,000 - 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,500 135 54 63 25 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 355 Technical data and characteristics 6.1 Induction motors Table 6- 129 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8107-F nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 10 55 22 9,000 12,000 - 5,000 5,000 135 1,500 9 57 23.5 Imax [A] M0 [Nm] I0 [A] 54 63 25 6,250 1PH8 main motors 356 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 130 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8107-F nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 2,000 11 53 21.5 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 9,000 12,000 - 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 5,500 135 54 63 25 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 357 Technical data and characteristics 6.1 Induction motors Table 6- 131 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8107-F nN PN MN IN [rpm] [kW] [Nm] [A] 2,200 12.1 53 21.5 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 9,000 12,000 -- 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 6,000 135 54 63 25 1PH8 main motors 358 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 132 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8107-G nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 2,000 10.5 50 26 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 9,000 12,000 - 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,000 126 63 63 29 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 359 Technical data and characteristics 6.1 Induction motors Table 6- 133 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8107-G nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 2,300 12 50 26 9,000 12,000 - 5,000 4,600 126 2,000 10.5 50 26 Imax [A] M0 [Nm] I0 [A] 63 63 29 7,000 1PH8 main motors 360 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 134 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8107-G nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 2,650 13 47 24 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 9,000 12,000 - 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 7,000 126 63 63 29 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 361 Technical data and characteristics 6.1 Induction motors Table 6- 135 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8107-G nN PN MN IN [rpm] [kW] [Nm] [A] 2,800 13.7 47 24 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 9,000 12,000 -- 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 7,000 126 63 63 29 1PH8 main motors 362 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 136 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8107-M nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 3,000 12 38 38 9,000 12,000 18,000 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 16,500 170 166 59 48 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 363 Technical data and characteristics 6.1 Induction motors Table 6- 137 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8107-M nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 3,300 13 38 38 9,000 12,000 18,000 5,000 18,000 170 3,000 12 38 38 Imax [A] M0 [Nm] I0 [A] 166 59 48 18,000 1PH8 main motors 364 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 138 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8107-M nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 3,600 14 37 37.5 9,000 12,000 18,000 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 18,000 170 166 59 48 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 365 Technical data and characteristics 6.1 Induction motors Table 6- 139 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8107-M nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 3,900 14 34 35 9,000 12,000 18,000 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 18,000 170 166 59 48 1PH8 main motors 366 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 140 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8107-S, connection nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 4,000 8.5 20 28 9,000 12,000 18,000 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 10,000 80 100 42 40 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 367 Technical data and characteristics 6.1 Induction motors Table 6- 141 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8107-S, connection nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 5,000 11 21 28 9,000 12,000 18,000 5,000 10,000 80 4,000 8.5 20 28 Imax [A] M0 [Nm] I0 [A] 100 42 40 12,000 1PH8 main motors 368 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 142 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8107-S, connection nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 6,000 12.8 20 28 9,000 12,000 18,000 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 10,000 80 100 42 40 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 369 Technical data and characteristics 6.1 Induction motors Table 6- 143 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8107-S, connection nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 7,000 15 20 28 9,000 12,000 18,000 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 11,000 80 100 42 40 1PH8 main motors 370 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 144 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8107-S, Y connection nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 1,500 8.5 54 27 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 9,000 12,000 - 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 8,550 135 66 63 30 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 371 Technical data and characteristics 6.1 Induction motors Table 6- 145 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8107-S, Y connection nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 2,000 11 53 26.7 9,000 12,000 - 5,000 8,550 135 1,500 8.5 54 27 Imax [A] M0 [Nm] I0 [A] 66 63 30 10,600 1PH8 main motors 372 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 146 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8107-S, Y connection nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 2,500 14 53 26.5 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 9,000 12,000 - 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 8,050 135 66 63 30 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 373 Technical data and characteristics 6.1 Induction motors Table 6- 147 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8107-S, Y connection nN PN MN IN [rpm] [kW] [Nm] [A] 3,000 16 51 26 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 9,000 12,000 -- 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 7,000 135 66 63 30 1PH8 main motors 374 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors 6.1.2.4 Shaft height 132 - forced ventilation Table 6- 148 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8131-B nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 400 2.9 69 9 - - - 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,500 134 22 76 10 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 375 Technical data and characteristics 6.1 Induction motors Table 6- 149 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8131-B nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 500 3.6 69 9 400 2.9 69 9 - - - 4,500 n2 [rpm] 1,500 2,000 Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 134 22 76 10 1PH8 main motors 376 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 150 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8131-B nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 600 4.3 68 9 - - - 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,500 134 22 76 10 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 377 Technical data and characteristics 6.1 Induction motors Table 6- 151 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8131-B nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 700 4.9 67 9 -- -- -- 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,700 134 22 76 10 1PH8 main motors 378 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 152 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8131-D, Y connection nN PN MN IN [rpm] [kW] [Nm] [A] 1,000 7.9 75 20 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 8,000 10,000 -- 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,000 170 44 84 21 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 379 Technical data and characteristics 6.1 Induction motors Table 6- 153 SINAMICS, 3-ph. 400 V AC, Active Line Module, (ALM), 1PH8131-D, Y connection nN PN MN IN nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,150 9 75 20 8,000 10,000 -- 4,500 3,000 170 1,000 7.9 75 20 Imax [A] M0 [Nm] I0 [A] 44 84 21 3,550 1PH8 main motors 380 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 154 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8131-D, Y connection nN PN MN IN [rpm] [kW] [Nm] [A] 1,350 10.6 75 20 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 8,000 10,000 -- 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,000 170 44 84 21 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 381 Technical data and characteristics 6.1 Induction motors Table 6- 155 SINAMICS, 3-ph. 480 V AC, Active Line Module, (ALM), 1PH8131-D, Y connection nN PN MN IN [rpm] [kW] [Nm] [A] 1,500 11.7 74 20 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 8,000 10,000 -- 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,000 170 44 84 21 1PH8 main motors 382 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 156 SINAMICS, 3-ph. 400 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8131-F nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 1,500 11 70 24 8,000 10,000 11,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,800 148 50 96 30 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 383 Technical data and characteristics 6.1 Induction motors Table 6- 157 SINAMICS, 3-ph. 400 V AC, Active Line Module, (ALM), 1PH8131-F nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] [rpm] [kW] [Nm] [A] 1,750 13 71 24 1,500 11 70 24 8,000 10,000 11,000 4,500 n2 [rpm] 5,150 6,050 Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 148 50 96 30 1PH8 main motors 384 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 158 SINAMICS, 3-ph. 480 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8131-F nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,000 15 72 24 8,000 10,000 11,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 5,300 148 50 96 30 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 385 Technical data and characteristics 6.1 Induction motors Table 6- 159 SINAMICS, 3-ph. 480 V AC, Active Line Module, (ALM), 1PH8131-F nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,200 16.5 72 24 8,000 10,000 11,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,500 148 50 96 30 1PH8 main motors 386 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 160 SINAMICS, 3-ph. 400 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8131-S, connection nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 4,000 11 26 40 8,000 10,000 15,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 10,000 80 114 55 56 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 387 Technical data and characteristics 6.1 Induction motors Table 6- 161 SINAMICS, 3-ph. 400 V AC, Active Line Module, (ALM), 1PH8131-S, connection nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 5,000 14.6 28 40 8,000 10,000 15,000 4,500 10,000 80 4,000 11 28 40 Imax [A] M0 [Nm] I0 [A] 114 55 56 13,000 1PH8 main motors 388 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 162 SINAMICS, 3-ph. 480 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8131-S, connection nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 6,000 18 29 35 8,000 10,000 15,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 10,000 80 114 55 56 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 389 Technical data and characteristics 6.1 Induction motors Table 6- 163 SINAMICS, 3-ph. 480 V AC, Active Line Module, (ALM), 1PH8131-S, connection nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 7,000 19.8 27 34 8,000 10,000 15,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 10,000 80 114 55 56 1PH8 main motors 390 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 164 SINAMICS, 3-ph. 400 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8131-S, Y connection nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 1,500 11 70 39 8,000 10,000 14,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 8,000 200 111 94 47 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 391 Technical data and characteristics 6.1 Induction motors Table 6- 165 SINAMICS, 3-ph. 400 V AC, Active Line Module, (ALM), 1PH8131-S, Y connection nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 2,000 14.6 70 39 8,000 10,000 14,000 4,500 8,000 200 1,500 11 70 39 Imax [A] M0 [Nm] I0 [A] 111 94 47 10,000 1PH8 main motors 392 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 166 SINAMICS, 3-ph. 480 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8131-S, Y connection nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,500 18 69 38 8,000 10,000 14,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 7,500 200 111 94 47 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 393 Technical data and characteristics 6.1 Induction motors Table 6- 167 SINAMICS, 3-ph. 480 V AC, Active Line Module, (ALM), 1PH8131-S, Y connection nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 3,000 19.8 63 36.5 8,000 10,000 14,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 8,000 200 111 94 47 1PH8 main motors 394 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 168 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8133-B nN PN MN IN nmax1 nmax2 nmax3 [rpm] [kW] 400 5.2 nmax, Br [Nm] [A] [rpm] [rpm] [rpm] [rpm] 124 15.5 - - - 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,000 155 19 124 16 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 395 Technical data and characteristics 6.1 Induction motors Table 6- 169 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8133-B nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] 500 6.5 [Nm] [A] [rpm] [rpm] [rpm] [rpm] 124 15.5 400 5.2 124 15.5 - - - 4,500 n2 [rpm] 1,200 1,650 Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 155 19 124 16 1PH8 main motors 396 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 170 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8133-B nN PN MN IN nmax1 nmax2 nmax3 [rpm] [kW] 600 7.8 nmax, Br [Nm] [A] [rpm] [rpm] [rpm] [rpm] 124 15.5 - - - 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,200 155 19 124 16 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 397 Technical data and characteristics 6.1 Induction motors Table 6- 171 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8133-B nN PN MN IN nmax1 nmax2 nmax3 [rpm] [kW] 700 9.1 nmax, Br [Nm] [A] [rpm] [rpm] [rpm] [rpm] 124 15.5 -- -- -- 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,200 155 19 124 16 1PH8 main motors 398 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 172 SINAMICS, 3-ph. 400 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8133-D nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 1,000 12 115 30 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 8,000 10,000 - 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,000 250 65 126 32 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 399 Technical data and characteristics 6.1 Induction motors Table 6- 173 SINAMICS, 3-ph. 400 V AC, Active Line Module, (ALM), 1PH8133-D nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] [rpm] [kW] [Nm] [A] 1,150 13.5 112 29 1,000 12 115 30 8,000 10,000 - 4,500 n2 [rpm] 3,000 4,600 Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 250 65 126 32 1PH8 main motors 400 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 174 SINAMICS, 3-ph. 480 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8133-D nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 1,350 15 106 28 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 8,000 10,000 - 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,500 250 65 126 32 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 401 Technical data and characteristics 6.1 Induction motors Table 6- 175 SINAMICS, 3-ph. 480 V AC, Active Line Module, (ALM), 1PH8133-D nN PN MN IN [rpm] [kW] [Nm] [A] 1,500 16.6 106 28 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 8,000 10,000 -- 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,000 250 65 126 32 1PH8 main motors 402 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 176 SINAMICS, 3-ph. 400 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8133-F nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 1,500 15 96 34 8,000 10,000 13,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 5,500 240 85 126 42 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 403 Technical data and characteristics 6.1 Induction motors Table 6- 177 SINAMICS, 3-ph. 400 V AC, Active Line Module, (ALM), 1PH8133-F nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 17.5 96 34 8,000 10,000 13,000 4,500 5,000 240 1,500 15 96 34 Imax [A] M0 [Nm] I0 [A] 85 126 42 6,900 1PH8 main motors 404 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 178 SINAMICS, 3-ph. 480 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8133-F nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,000 20 96 34 8,000 10,000 13,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 6,200 240 85 126 42 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 405 Technical data and characteristics 6.1 Induction motors Table 6- 179 SINAMICS, 3-ph. 480 V AC, Active Line Module, (ALM), 1PH8133-F nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,200 22 96 34 8,000 10,000 13,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 6,000 240 85 126 42 1PH8 main motors 406 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 180 SINAMICS, 3-ph. 400 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8133-G nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,000 20 96 45 8,000 10,000 15,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,000 250 117 126 54 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 407 Technical data and characteristics 6.1 Induction motors Table 6- 181 SINAMICS, 3-ph. 400 V AC, Active Line Module, (ALM), 1PH8133-G nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 2,300 22.5 93 44 8,000 10,000 15,000 4,500 5,000 250 2,000 20 96 45 Imax [A] M0 [Nm] I0 [A] 117 126 54 6,500 1PH8 main motors 408 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 182 SINAMICS, 3-ph. 480 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8133-G nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,650 24 86 41 8,000 10,000 15,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 7,000 250 117 126 54 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 409 Technical data and characteristics 6.1 Induction motors Table 6- 183 SINAMICS, 3-ph. 480 V AC, Active Line Module, (ALM), 1PH8133-G nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,800 25 85 41 8,000 10,000 15,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 7,000 250 117 126 54 1PH8 main motors 410 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 184 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8135-B nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 400 6.4 153 18 - - - 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,000 200 23 162 19 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 411 Technical data and characteristics 6.1 Induction motors Table 6- 185 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8135-B nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 500 8 153 18 400 6.4 153 18 - - - 4,500 n2 [rpm] 1,000 1,900 Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 200 23 162 19 1PH8 main motors 412 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 186 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8135-B nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 600 9.6 153 18 - - - 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,000 200 23 153 19 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 413 Technical data and characteristics 6.1 Induction motors Table 6- 187 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8135-B nN [rpm] 700 PN [kW] 11.2 MN IN [Nm] 153 [A] 18 nmax1 [rpm] -- nmax2 [rpm] -- nmax3 [rpm] -- nmax, Br [rpm] 4,500 n2 [rpm] 1,000 Mmax [Nm] 200 Imax [A] 23 M0 [Nm] 162 I0 [A] 19 1PH8 main motors 414 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 188 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8135-F nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 1,500 18.5 118 43 8,000 10,000 14,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 6,150 313 117 157 53 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 415 Technical data and characteristics 6.1 Induction motors Table 6- 189 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8135-F nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 21.5 117 43 8,000 10,000 14,000 4,500 5,500 313 1,500 18.5 118 43 Imax [A] M0 [Nm] I0 [A] 117 157 53 7,500 1PH8 main motors 416 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 190 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8135-F nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,000 24 115 43 8,000 10,000 14,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 7,100 313 117 157 53 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 417 Technical data and characteristics 6.1 Induction motors Table 6- 191 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8135-F nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,200 26.4 115 43 8,000 10,000 14,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 6,000 313 117 157 53 1PH8 main motors 418 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 192 SINAMICS, 3-ph. 400 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8135-G, Y connection nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,000 21.5 103 51 8,000 10,000 15,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,000 340 168 136 63 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 419 Technical data and characteristics 6.1 Induction motors Table 6- 193 SINAMICS, 3-ph. 400 V AC, Active Line Module, (ALM), 1PH8135-G, Y connection nN PN MN IN nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 2,300 24 100 50 8,000 10,000 15,000 4,500 5,000 340 2,000 21.5 103 51 Imax [A] M0 [Nm] I0 [A] 168 136 63 5,500 1PH8 main motors 420 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 194 SINAMICS, 3-ph. 480 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8135-G, Y connection nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,650 26 94 48 8,000 10,000 15,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 6,000 340 168 136 63 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 421 Technical data and characteristics 6.1 Induction motors Table 6- 195 SINAMICS, 3-ph. 480 V AC, Active Line Module, (ALM), 1PH8135-G, Y connection nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,800 26 89 47 8,000 10,000 15,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 6,000 340 168 136 63 1PH8 main motors 422 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 196 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8135-S, connection nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 4,000 18.5 44 51 8,000 10,000 15,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 10,500 131 145 94 78 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 423 Technical data and characteristics 6.1 Induction motors Table 6- 197 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8135-S, connection nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 5,000 24.5 47 52 8,000 10,000 15,000 4,500 10,000 131 4,000 18.5 44 51 Imax [A] M0 [Nm] I0 [A] 145 94 78 13,000 1PH8 main motors 424 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 198 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8135-S, connection nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 6,000 30.5 49 50 8,000 10,000 15,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 9,500 131 145 94 78 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 425 Technical data and characteristics 6.1 Induction motors Table 6- 199 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8135-S, connection nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 7,000 32 44 51 8,000 10,000 15,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 9,500 131 145 94 78 1PH8 main motors 426 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 200 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8135-S, Y connection nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 1,500 18.5 118 51 8,000 10,000 15,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 6,500 300 132 157 62 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 427 Technical data and characteristics 6.1 Induction motors Table 6- 201 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8135-S, Y connection nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 2,000 24.5 117 51 8,000 10,000 15,000 4,500 6,500 300 1,500 18.5 118 51 Imax [A] M0 [Nm] I0 [A] 132 157 62 8,000 1PH8 main motors 428 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 202 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8135-S, Y connection nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,500 30.5 117 50 8,000 10,000 15,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 6,000 300 132 157 62 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 429 Technical data and characteristics 6.1 Induction motors Table 6- 203 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8135-S, Y connection nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 3,000 35 111 51 8,000 10,000 15,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 6,000 300 132 157 62 1PH8 main motors 430 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 204 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8137-B nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 400 6.9 165 18 - - - 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,300 264 28 171 19 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 431 Technical data and characteristics 6.1 Induction motors Table 6- 205 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8137-B nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 500 8.6 165 18 400 6.9 165 18 - - - 4,500 n2 [rpm] 1,400 1,900 Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 264 28 171 19 1PH8 main motors 432 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 206 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8137-B nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 600 10.3 165 18 - - - 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,300 264 28 171 19 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 433 Technical data and characteristics 6.1 Induction motors Table 6- 207 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8137-B nN PN MN IN nmax1 nmax2 nmax3 [rpm] [kW] 700 11.5 nmax, Br [Nm] [A] [rpm] [rpm] [rpm] [rpm] 157 17.5 -- -- -- 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,300 264 28 171 19 1PH8 main motors 434 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 208 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8137-D nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 1,000 17 162 43 8,000 10,000 12,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,300 405 108 176 45 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 435 Technical data and characteristics 6.1 Induction motors Table 6- 209 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8137-D nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] [rpm] [kW] [Nm] [A] 1,150 19.5 162 43 1,000 17 162 43 8,000 10,000 12,000 4,500 n2 [rpm] 4,000 5,400 Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 405 108 176 45 1PH8 main motors 436 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 210 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8137-D nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 1,350 22 156 42 8,000 10,000 12,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,000 405 108 176 45 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 437 Technical data and characteristics 6.1 Induction motors Table 6- 211 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8137-D nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 1,500 24 153 41 8,000 10,000 12,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,500 405 108 176 45 1PH8 main motors 438 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 212 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8137-F nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 1,500 22 140 56 8,000 10,000 15,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 5,000 380 151 172 68 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 439 Technical data and characteristics 6.1 Induction motors Table 6- 213 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8137-F nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 25 136 56 8,000 10,000 15,000 4,500 5,000 380 1,500 22 140 56 Imax [A] M0 [Nm] I0 [A] 151 172 68 7,000 1PH8 main motors 440 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 214 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8137-F nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,000 28 134 55 8,000 10,000 15,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,000 380 151 172 68 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 441 Technical data and characteristics 6.1 Induction motors Table 6- 215 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8137-F nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,200 30 130 53 8,000 10,000 15,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,500 380 151 172 68 1PH8 main motors 442 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 216 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8137-G nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,000 28 134 60 8,000 10,000 15,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,000 340 152 176 73 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 443 Technical data and characteristics 6.1 Induction motors Table 6- 217 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8137-G nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 2,300 29 120 56 8,000 10,000 15,000 4,500 5,000 340 2,000 28 134 60 Imax [A] M0 [Nm] I0 [A] 152 176 73 5,500 1PH8 main motors 444 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 218 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8137-G nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,650 30 108 52 8,000 10,000 15,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,250 340 152 176 73 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 445 Technical data and characteristics 6.1 Induction motors Table 6- 219 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8137-G nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,800 31 106 52 8,000 10,000 15,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,000 340 152 176 73 1PH8 main motors 446 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 220 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8137-S, connection nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 4,000 22 53 55 8,000 10,000 15,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 6,500 160 160 105 87 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 447 Technical data and characteristics 6.1 Induction motors Table 6- 221 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8137-S, connection nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 5,000 27.5 53 56 8,000 10,000 15,000 4,500 6,000 160 4,000 22 53 55 Imax [A] M0 [Nm] I0 [A] 160 105 87 8,000 1PH8 main motors 448 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 222 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8137-S, connection nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 6,000 33 53 55 8,000 10,000 15,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 6,000 160 160 105 87 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 449 Technical data and characteristics 6.1 Induction motors Table 6- 223 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8137-S, connection nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 7,000 37 50 53 8,000 10,000 15,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 8,000 160 160 105 87 1PH8 main motors 450 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 224 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8137-S, Y connection nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 1,500 22 140 56 8,000 10,000 15,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,500 320 130 185 68 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 451 Technical data and characteristics 6.1 Induction motors Table 6- 225 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8137-S, Y connection nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 2,000 29 138 56 8,000 10,000 15,000 4,500 3,000 320 1,500 22 140 56 Imax [A] M0 [Nm] I0 [A] 130 185 68 5,700 1PH8 main motors 452 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 226 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8137-S, Y connection nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,500 36 138 50 8,000 10,000 15,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,000 320 130 185 68 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 453 Technical data and characteristics 6.1 Induction motors Table 6- 227 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8137-S, Y connection nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 3,000 37 118 54 8,000 10,000 15,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,000 320 130 185 68 1PH8 main motors 454 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors 6.1.2.5 Shaft height 160 - forced ventilation Table 6- 228 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8163-B nrated Prated Mrated Irated nmax1 nmax2 nmax3 [rpm] [kW] [Nm] 400 9.5 227 nmax, Br [A] [kW] [rpm] [rpm] [rpm] 30 6,500 - - 4,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,150 570 70 253 32 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 455 Technical data and characteristics 6.1 Induction motors Table 6- 229 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8163-B, nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 500 12 229 30 400 9.5 227 30 6,500 - - 4,000 n2 [rpm] 2,200 2,750 Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 570 70 253 32 1PH8 main motors 456 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 230 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8163-B nrated Prated Mrated Irated nmax1 nmax2 nmax3 [rpm] [kW] [Nm] 600 14.5 231 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 30 6,500 - - 4,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,150 570 70 253 32 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 457 Technical data and characteristics 6.1 Induction motors Table 6- 231 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8163-B nN PN MN IN nmax1 nmax2 nmax3 [rpm] [kW] [Nm] 700 16.9 231 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 30 6,500 -- -- 4,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,250 570 70 253 32 1PH8 main motors 458 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 232 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8163-D nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] 1,000 22 210 55 6,500 9,000 10,000 4,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,800 600 151 248 61 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 459 Technical data and characteristics 6.1 Induction motors Table 6- 233 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8163-D nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] [rpm] [kW] [Nm] [A] 1,150 25 208 55 1,000 22 210 55 6,500 9,000 10,000 4,000 n2 [rpm] 3,550 4,550 Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 600 151 248 61 1PH8 main motors 460 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 234 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8163-D nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 1,350 28 198 52 6,500 9,000 10,000 4,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,000 600 151 248 61 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 461 Technical data and characteristics 6.1 Induction motors Table 6- 235 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8163-D nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 1,500 31 197 52 6,500 9,000 10,000 4,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,000 600 151 248 61 1PH8 main motors 462 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 236 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8163-F nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] 1,500 30 191 71 6,500 9,000 10,000 4,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,500 600 217 252 87 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 463 Technical data and characteristics 6.1 Induction motors Table 6- 237 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8163-F nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] [rpm] [kW] [Nm] [A] 1,750 34 186 70 1,500 30 191 71 6,500 9,000 10,000 4,000 n2 [rpm] 3,050 5,000 Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 600 217 252 87 1PH8 main motors 464 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 238 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8163-F nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,000 37 177 68 6,500 9,000 10,000 4,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,550 600 217 252 87 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 465 Technical data and characteristics 6.1 Induction motors Table 6- 239 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8163-F nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,200 40.7 177 68 6,500 9,000 10,000 4,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,500 600 217 252 87 1PH8 main motors 466 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 240 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8163-G nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] 2,000 36 172 83 6,500 9,000 10,000 4,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,000 570 272 254 111 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 467 Technical data and characteristics 6.1 Induction motors Table 6- 241 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8163-G nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] [rpm] [kW] [Nm] [A] 2,300 38 158 78 2,000 36 172 83 6,500 9,000 10,000 4,000 n2 [rpm] 3,200 3,500 Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 570 272 245 111 1PH8 main motors 468 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 242 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8163-G nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,650 40 144 76 6,500 9,000 10,000 4,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,500 570 272 254 111 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 469 Technical data and characteristics 6.1 Induction motors Table 6- 243 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8163-G nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,800 42 143 75 6,500 9,000 10,000 4,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,500 570 272 254 111 1PH8 main motors 470 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 244 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8165-B nrated Prated Mrated Irated nmax1 nmax2 nmax3 [rpm] [kW] [Nm] 400 13 310 nmax, Br [A] [kW] [rpm] [rpm] [rpm] 36 6,500 - - 4,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,750 610 75 329 37 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 471 Technical data and characteristics 6.1 Induction motors Table 6- 245 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8165-B nrated Prated Mrated Irated nmax1 nmax2 nmax3 [rpm] [kW] [Nm] 500 16 306 400 13 310 36 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 36 6,500 - - 4,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,850 610 75 329 37 2,300 1PH8 main motors 472 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 246 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8165-B nrated Prated Mrated Irated nmax1 nmax2 nmax3 [rpm] [kW] [Nm] 600 19 302 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 35 6,500 - - 4,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,800 610 75 329 37 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 473 Technical data and characteristics 6.1 Induction motors Table 6- 247 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8165-B nN PN MN IN nmax1 nmax2 nmax3 [rpm] [kW] [Nm] 700 22 300 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 35 6,500 -- -- 4,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,900 610 75 329 37 1PH8 main motors 474 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 248 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8165-D nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] 1,000 28 267 71 6,500 9,000 10,000 4,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,600 740 192 302 77 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 475 Technical data and characteristics 6.1 Induction motors Table 6- 249 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8165-D nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,150 31 257 69 6,500 9,000 10,000 4,000 4,850 740 1,000 28 267 71 Imax [A] M0 [Nm] I0 [A] 192 302 77 5,550 1PH8 main motors 476 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 250 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8165-D nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 1,350 34 241 66 6,500 9,000 10,000 4,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 5,600 740 192 302 77 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 477 Technical data and characteristics 6.1 Induction motors Table 6- 251 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8165-D nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 1,500 37.7 240 65 6,500 9,000 10,000 4,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 5,000 740 192 302 77 1PH8 main motors 478 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 252 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8165-F nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] 1,500 37 236 78 6,500 9,000 10,000 4,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,800 630 206 304 95 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 479 Technical data and characteristics 6.1 Induction motors Table 6- 253 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8165-F nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 41 224 76 6,500 9,000 10,000 4,000 2,650 630 1,500 37 236 78 Imax [A] M0 [Nm] I0 [A] 206 304 95 4,550 1PH8 main motors 480 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 254 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8165-F nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,000 45 215 75 6,500 9,000 10,000 4,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,300 630 206 304 95 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 481 Technical data and characteristics 6.1 Induction motors Table 6- 255 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8165-F nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,200 49.5 215 75 6,500 9,000 10,000 4,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,500 630 206 304 95 1PH8 main motors 482 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 256 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8165-G nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] 2,000 41 196 88 6,500 9,000 10,000 4,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,750 620 278 302 122 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 483 Technical data and characteristics 6.1 Induction motors Table 6- 257 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8165-G nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 2,300 44 183 85 6,500 9,000 10,000 4,000 3,000 620 2,000 41 196 88 Imax [A] M0 [Nm] I0 [A] 278 302 122 3,200 1PH8 main motors 484 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 258 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8165-G nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,650 50 180 85 6,500 9,000 10,000 4,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,250 620 278 302 122 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 485 Technical data and characteristics 6.1 Induction motors Table 6- 259 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8165-G nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,800 50 171 81 6,500 9,000 10,000 4,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,500 620 278 302 122 1PH8 main motors 486 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors 6.1.2.6 Shaft height 180 - forced ventilation Table 6- 260 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8184-B, (IP55) nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 400 16.3 389 49 nmax1 nmax2 nmax3 nmax, Br [kW] [rpm] [rpm] [rpm] 5,000 7,500 - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,800 925 124 389 49 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 487 Technical data and characteristics 6.1 Induction motors Table 6- 261 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8184-B, (IP55) nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 500 20.5 392 49 400 16.3 389 49 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 5,000 7,500 - 3,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,900 925 124 392 49 3,700 1PH8 main motors 488 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 262 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8184-B, (IP55) nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 600 25 398 49 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 5,000 7,500 - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,000 925 124 398 49 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 489 Technical data and characteristics 6.1 Induction motors Table 6- 263 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8184-B, (IP55) nN PN MN IN [rpm] [kW] [Nm] [A] 700 29 396 49 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 5,000 7,500 - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,100 925 124 389 49 1PH8 main motors 490 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 264 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8184-C, (IP55) nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 700 27 368 65 nmax1 nmax2 nmax3 nmax, Br [kW] [rpm] [rpm] [rpm] 5,000 7,500 - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,300 925 164 368 65 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 491 Technical data and characteristics 6.1 Induction motors Table 6- 265 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8184-C, (IP55) nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 800 31 370 65 700 27 368 65 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 5,000 7,500 - 3,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,800 925 164 370 65 4,300 1PH8 main motors 492 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 266 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8184-C, (IP55) nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 1,000 39 372 65 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 5,000 7,500 - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,700 925 164 372 65 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 493 Technical data and characteristics 6.1 Induction motors Table 6- 267 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8184-C, (IP55) nN PN MN IN [rpm] [kW] [Nm] [A] 1,100 42 365 64 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 5,000 7,500 - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,800 925 164 368 64 1PH8 main motors 494 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 268 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8184-D, (IP55) nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 1,000 39 372 87 nmax1 nmax2 nmax3 nmax, Br [kW] [rpm] [rpm] [rpm] 5,000 7,500 - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,200 925 205 372 87 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 495 Technical data and characteristics 6.1 Induction motors Table 6- 269 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8184-D, (IP55) nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,150 44 365 86 5,000 7,500 - 3,500 4,800 925 1,000 39 372 87 Imax [A] M0 [Nm] I0 [A] 205 365 86 5,100 1PH8 main motors 496 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 270 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8184-D, (IP55) nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 1,350 50 354 84 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 5,000 7,500 - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 5,000 925 205 354 84 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 497 Technical data and characteristics 6.1 Induction motors Table 6- 271 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8184-D, (IP55) nN PN MN IN [rpm] [kW] [Nm] [A] 1,500 53 337 80 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 5,000 7,500 - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 5,000 925 205 372 80 1PH8 main motors 498 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 272 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8184-F, (IP55) nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 1,500 51 325 116 nmax1 nmax2 nmax3 nmax, Br [kW] [rpm] [rpm] [rpm] 5,000 7,500 - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 5,000 925 300 325 116 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 499 Technical data and characteristics 6.1 Induction motors Table 6- 273 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8184-F, (IP55) nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 60 327 120 5,000 7,500 - 3,500 5,000 925 1,500 51 325 116 Imax [A] M0 [Nm] I0 [A] 300 327 120 5,600 1PH8 main motors 500 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 274 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8184-F, (IP55) nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 2,000 68 325 118 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 5,000 7,500 - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 5,000 925 300 325 118 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 501 Technical data and characteristics 6.1 Induction motors Table 6- 275 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8184-F, (IP55) nN PN MN IN [rpm] [kW] [Nm] [A] 2,200 68 295 110 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 5,000 7,500 - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 5,000 925 300 325 110 1PH8 main motors 502 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 276 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8184-L, (IP55) nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 2,500 78 298 166 nmax1 nmax2 nmax3 nmax, Br [kW] [rpm] [rpm] [rpm] 5,000 7,500 - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 5,000 730 380 298 166 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 503 Technical data and characteristics 6.1 Induction motors Table 6- 277 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8184-L, (IP55) nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 2,900 81 267 152 5,000 7,500 - 3,500 5,000 730 2,500 78 298 166 Imax [A] M0 [Nm] I0 [A] 380 267 152 5,100 1PH8 main motors 504 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 278 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8184-L, (IP55) nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 3,400 65 183 120 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 5,000 7,500 - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 5,000 730 380 183 120 Note: In this electrical version (L winding), supplementary losses that are disproportionately high relative to the speed occur at high connection voltages (480 V 3AC), depending on the modulation depth of the converter. To comply with the permissible motor temperature, a power reduction must be considered in the configuration. 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 505 Technical data and characteristics 6.1 Induction motors Table 6- 279 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8186-B, (IP55) nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 400 21.2 506 65 nmax1 nmax2 nmax3 nmax, Br [kW] [rpm] [rpm] [rpm] 5,000 7,500 - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,000 1,230 156 506 65 1PH8 main motors 506 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 280 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8186-B, (IP55) nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 500 26.5 506 65 400 21.2 506 65 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 5,000 7,500 - 3,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,100 1,230 156 506 65 4,100 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 507 Technical data and characteristics 6.1 Induction motors Table 6- 281 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8186-B, (IP55) nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 600 32 509 66 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 5,000 7,500 - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,200 1,230 156 509 66 1PH8 main motors 508 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 282 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8186-B, (IP55) nN PN MN IN [rpm] [kW] [Nm] [A] 700 37 505 65 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 5,000 7,500 - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,400 1,230 156 506 65 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 509 Technical data and characteristics 6.1 Induction motors Table 6- 283 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8186-C, (IP55) nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 700 35 478 83 nmax1 nmax2 nmax3 nmax, Br [kW] [rpm] [rpm] [rpm] 5,000 7,500 - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,700 1,230 205 478 83 1PH8 main motors 510 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 284 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8186-C, (IP55) nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 800 40 478 83 700 35 478 83 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 5,000 7,500 - 3,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,100 1,230 205 478 83 4,700 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 511 Technical data and characteristics 6.1 Induction motors Table 6- 285 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8186-C, (IP55) nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 1,000 50 478 83 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 5,000 7,500 - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,000 1,230 205 478 83 1PH8 main motors 512 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 286 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8186-C, (IP55) nN PN MN IN [rpm] [kW] [Nm] [A] 1,100 55 478 83 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 5,000 7,500 - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,100 1,230 205 478 83 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 513 Technical data and characteristics 6.1 Induction motors Table 6- 287 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8186-D, (IP55) nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 1,000 51 487 112 nmax1 nmax2 nmax3 nmax, Br [kW] [rpm] [rpm] [rpm] 5,000 7,500 - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,400 1,230 265 487 112 1PH8 main motors 514 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 288 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8186-D, (IP55) nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,150 58 482 112 5,000 7,500 - 3,500 5,000 1,230 1,000 51 487 112 Imax [A] M0 [Nm] I0 [A] 265 482 112 5,400 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 515 Technical data and characteristics 6.1 Induction motors Table 6- 289 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8186-D, (IP55) nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 1,350 67 474 112 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 5,000 7,500 - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 5,000 1,230 265 474 112 1PH8 main motors 516 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 290 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8186-D, (IP55) nN PN MN IN [rpm] [kW] [Nm] [A] 1,500 73 465 110 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 5,000 7,500 - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 5,000 1,230 265 487 110 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 517 Technical data and characteristics 6.1 Induction motors Table 6- 291 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8186-F, (IP55) nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 1,500 74 471 166 nmax1 nmax2 nmax3 nmax, Br [kW] [rpm] [rpm] [rpm] 5,000 7,500 - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 5,000 1,230 400 471 166 1PH8 main motors 518 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 292 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8186-F, (IP55) nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 85 464 164 5,000 7,500 - 3,500 5,000 1,230 1,500 74 471 166 Imax [A] M0 [Nm] I0 [A] 400 464 164 5,400 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 519 Technical data and characteristics 6.1 Induction motors Table 6- 293 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8186-F, (IP55) nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 2,000 94 449 160 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 5,000 7,500 - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 5,000 1,230 400 449 160 1PH8 main motors 520 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 294 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8186-F, (IP55) nN PN MN IN [rpm] [kW] [Nm] [A] 2,200 94 408 140 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 5,000 7,500 - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 5,000 1,230 400 471 140 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 521 Technical data and characteristics 6.1 Induction motors Table 6- 295 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8186-L, (IP55) nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 2,500 106 405 230 nmax1 nmax2 nmax3 nmax, Br [kW] [rpm] [rpm] [rpm] 5,000 7,500 - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 5,000 920 480 405 230 1PH8 main motors 522 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 296 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8186-L, (IP55) nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 2,900 101 333 198 5,000 75,000 - 3,500 5,000 920 - - - - Imax [A] M0 [Nm] I0 [A] 480 333 198 - 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 523 Technical data and characteristics 6.1 Induction motors Table 6- 297 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8186-L, (IP55) nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 3,400 81 228 158 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 5,000 7,500 - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 5,000 920 480 228 158 Note: In this electrical version (L winding), supplementary losses that are disproportionately high relative to the speed occur at high connection voltages (480 V 3AC), depending on the modulation depth of the converter. To comply with the permissible motor temperature, a power reduction must be considered in the configuration. 1PH8 main motors 524 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors 6.1.2.7 Shaft height 180 - forced ventilation (open-circuit ventilation) Table 6- 298 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8184-B, (IP23) nrated Prated Mrated Irated nmax1 nmax2 nmax3 [rpm] [kW] [Nm] 400 24.5 585 nmax, Br [A] [kW] [rpm] [rpm] [rpm] 67 5,000 - - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,900 925 108 585 67 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 525 Technical data and characteristics 6.1 Induction motors Table 6- 299 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8184-B, (IP23) nrated Prated Mrated Irated nmax1 nmax2 nmax3 [rpm] [kW] [Nm] 500 30 573 400 24.5 585 67 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 65 5,000 - - 3,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,000 925 108 573 65 2,600 1PH8 main motors 526 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 300 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8184-B, (IP23) nrated Prated Mrated Irated nmax1 nmax2 nmax3 [rpm] [kW] [Nm] 600 36 573 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 64 5,000 - - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,100 925 108 573 64 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 527 Technical data and characteristics 6.1 Induction motors Table 6- 301 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8184-B, (IP23) nN PN MN IN nmax1 nmax2 nmax3 [rpm] [kW] [Nm] 700 42 573 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 65 5,000 - - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 925 108 585 65 1PH8 main motors 528 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 302 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8184-C, (IP23) nrated Prated Mrated Irated nmax1 nmax2 nmax3 [rpm] [kW] [Nm] 700 40 546 nmax, Br [A] [kW] [rpm] [rpm] [rpm] 94 5,000 - - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 925 168 546 94 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 529 Technical data and characteristics 6.1 Induction motors Table 6- 303 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8184-C, (IP23) nrated Prated Mrated Irated nmax1 nmax2 nmax3 [rpm] [kW] [Nm] 800 45 537 700 40 546 94 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 91 5,000 - - 3,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,300 925 168 537 91 2,800 1PH8 main motors 530 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 304 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8184-C, (IP23) nrated Prated Mrated Irated nmax1 nmax2 nmax3 [rpm] [kW] [Nm] 1,000 57 544 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 90 5,000 - - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,400 925 168 544 90 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 531 Technical data and characteristics 6.1 Induction motors Table 6- 305 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8184-C, (IP23) nN PN MN IN nmax1 nmax2 nmax3 [rpm] [kW] [Nm] 1,100 62 538 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 89 5,000 - - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,500 925 168 546 89 1PH8 main motors 532 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 306 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8184-D, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 1,000 57 544 Irated nmax1 nmax2 nmax3 nmax, Br [A] [kW] [rpm] [rpm] [rpm] 120 5,000 - - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,800 925 205 544 120 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 533 Technical data and characteristics 6.1 Induction motors Table 6- 307 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8184-D, (IP23) nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,150 65 540 120 5,000 - - 3,500 3,000 925 1,000 57 544 120 Imax [A] M0 [Nm] I0 [A] 205 540 120 3,400 1PH8 main motors 534 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 308 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8184-D, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 1,350 74 523 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 118 5,000 - - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,100 925 205 523 118 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 535 Technical data and characteristics 6.1 Induction motors Table 6- 309 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8184-D, (IP23) nN PN MN [rpm] [kW] [Nm] 1,500 76 484 IN nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 108 5,000 - - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,600 925 205 544 108 1PH8 main motors 536 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 310 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8184-F, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 1,500 76 484 Irated nmax1 nmax2 nmax3 nmax, Br [A] [kW] [rpm] [rpm] [rpm] 162 5,000 - - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,300 925 300 484 162 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 537 Technical data and characteristics 6.1 Induction motors Table 6- 311 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8184-F, (IP23) nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 89 486 162 5,000 - - 3,500 4,300 925 1,500 76 484 162 Imax [A] M0 [Nm] I0 [A] 300 486 162 5,000 1PH8 main motors 538 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 312 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8184-F, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 2,000 98 468 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 156 5,000 - - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,300 925 300 468 156 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 539 Technical data and characteristics 6.1 Induction motors Table 6- 313 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8184-F, (IP23) nN PN MN [rpm] [kW] [Nm] 2,200 98 425 IN nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 144 5,000 - - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,300 925 300 484 144 1PH8 main motors 540 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 314 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8184-L, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 2,500 100 382 Irated nmax1 nmax2 nmax3 nmax, Br [A] [kW] [rpm] [rpm] [rpm] 205 5,000 - - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 5,000 730 380 382 205 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 541 Technical data and characteristics 6.1 Induction motors Table 6- 315 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8184-L, (IP23) nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 2,900 113 372 200 5,000 - - 3,500 5,000 730 2,500 100 382 205 Imax [A] M0 [Nm] I0 [A] 380 372 200 5,000 1PH8 main motors 542 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 316 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8184-L, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 3,400 113 317 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 176 5,000 - - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,500 730 380 317 176 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 543 Technical data and characteristics 6.1 Induction motors Table 6- 317 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8186-B, (IP23) nrated Prated Mrated Irated nmax1 nmax2 nmax3 [rpm] [kW] [Nm] 400 31.5 752 nmax, Br [A] [kW] [rpm] [rpm] [rpm] 88 5,000 - - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,100 1,230 144 752 88 1PH8 main motors 544 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 318 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8186-B, (IP23) nrated Prated Mrated Irated nmax1 nmax2 nmax3 [rpm] [kW] [Nm] 500 40 764 400 31.5 752 88 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 88 5,000 - - 3,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 1,230 144 764 88 3,100 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 545 Technical data and characteristics 6.1 Induction motors Table 6- 319 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8186-B, (IP23) nrated Prated Mrated Irated nmax1 nmax2 nmax3 [rpm] [kW] [Nm] 600 48 764 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 88 5,000 - - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,300 1,230 144 764 88 1PH8 main motors 546 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 320 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8186-B, (IP23) nN PN MN IN nmax1 nmax2 nmax3 [rpm] [kW] [Nm] 700 56 764 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 88 5,000 - - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,400 1,230 144 752 88 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 547 Technical data and characteristics 6.1 Induction motors Table 6- 321 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8186-C, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 700 52 709 Irated nmax1 nmax2 nmax3 nmax, Br [A] [kW] [rpm] [rpm] [rpm] 116 5,000 - - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,400 1,230 210 709 116 1PH8 main motors 548 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 322 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8186-C, (IP23) nrated Prated Mrated Irated nmax1 nmax2 nmax3 [rpm] [kW] [Nm] 800 60 716 700 52 709 116 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 120 5,000 - - 3,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,500 1,230 210 716 120 3,200 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 549 Technical data and characteristics 6.1 Induction motors Table 6- 323 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8186-C, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 1,000 74 707 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 116 5,000 - - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,600 1,230 210 707 116 1PH8 main motors 550 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 324 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8186-C, (IP23) nN PN MN [rpm] [kW] [Nm] 1,100 80 695 IN nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 114 5,000 - - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,800 1,230 210 709 114 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 551 Technical data and characteristics 6.1 Induction motors Table 6- 325 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8186-D, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 1,000 74 707 Irated nmax1 nmax2 nmax3 nmax, Br [A] [kW] [rpm] [rpm] [rpm] 156 5,000 - - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,000 1,230 265 707 156 1PH8 main motors 552 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 326 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8186-D, (IP23) nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,150 85 706 154 5,000 - - 3,500 3,200 1,230 1,000 74 707 156 Imax [A] M0 [Nm] I0 [A] 265 706 154 3,800 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 553 Technical data and characteristics 6.1 Induction motors Table 6- 327 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8186-D, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 1,350 98 693 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 152 5,000 - - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,300 1,230 265 693 152 1PH8 main motors 554 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 328 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8186-D, (IP23) nN PN MN [rpm] [kW] [Nm] 1,500 105 669 IN nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 148 5,000 - - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,800 1,230 265 707 148 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 555 Technical data and characteristics 6.1 Induction motors Table 6- 329 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8186-F, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 1,500 108 688 Irated nmax1 nmax2 nmax3 nmax, Br [A] [kW] [rpm] [rpm] [rpm] 225 5,000 - - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,300 1,230 400 688 225 1PH8 main motors 556 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 330 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8186-F, (IP23) nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 125 682 225 5,000 - - 3,500 4,300 1,230 1,500 108 688 225 Imax [A] M0 [Nm] I0 [A] 400 682 225 5,000 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 557 Technical data and characteristics 6.1 Induction motors Table 6- 331 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8186-F, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 2,000 135 645 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 210 5,000 - - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,300 1,230 400 645 210 1PH8 main motors 558 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 332 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8186-F, (IP23) nN PN MN [rpm] [kW] [Nm] 2,200 135 586 IN nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 196 5,000 - - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,300 1,230 400 688 196 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 559 Technical data and characteristics 6.1 Induction motors Table 6- 333 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8186-L, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 2,500 130 497 Irated nmax1 nmax2 nmax3 nmax, Br [A] [kW] [rpm] [rpm] [rpm] 270 5,000 - - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 5,000 920 480 497 270 1PH8 main motors 560 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 334 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8186-L, (IP23) nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 2,900 150 494 270 5,000 - - 3,500 5,000 920 2,500 130 497 270 Imax [A] M0 [Nm] I0 [A] 480 494 270 5,000 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 561 Technical data and characteristics 6.1 Induction motors Table 6- 335 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8186-L, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 3,400 130 365 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 210 5,000 - - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,500 920 480 365 210 1PH8 main motors 562 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors 6.1.2.8 Shaft height 225 - forced ventilation Table 6- 336 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8224-B, (IP55) nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 400 30.4 726 86 nmax1 nmax2 nmax3 nmax, Br [kW] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,400 1,760 225 726 86 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 563 Technical data and characteristics 6.1 Induction motors Table 6- 337 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8224-B, (IP55) nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 500 38 726 85 400 30 726 86 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,500 1,760 225 726 85 3,100 1PH8 main motors 564 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 338 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8224-B, (IP55) nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 600 45 716 83 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,600 1,760 225 716 83 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 565 Technical data and characteristics 6.1 Induction motors Table 6- 339 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8224-B, (IP55) nN PN MN IN [rpm] [kW] [Nm] [A] 700 52 709 82 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,700 1,760 225 726 82 1PH8 main motors 566 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 340 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8224-C, (IP55) nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 700 55 750 136 nmax1 nmax2 nmax3 nmax, Br [kW] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,900 1,760 285 750 136 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 567 Technical data and characteristics 6.1 Induction motors Table 6- 341 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8224-C, (IP55) nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 800 57 681 126 700 55 750 136 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,400 1,760 285 681 126 3,900 1PH8 main motors 568 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 342 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8224-C, (IP55) nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 1,000 71 678 126 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,700 1,760 185 678 126 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 569 Technical data and characteristics 6.1 Induction motors Table 6- 343 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8224-C, (IP55) nN PN MN IN [rpm] [kW] [Nm] [A] 1,100 78 677 126 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,700 1,760 285 750 126 1PH8 main motors 570 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 344 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8224-D, (IP55) nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 1,000 71 678 158 nmax1 nmax2 nmax3 nmax, Br [kW] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,300 1,760 380 678 158 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 571 Technical data and characteristics 6.1 Induction motors Table 6- 345 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8224-D, (IP55) nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,150 81 673 156 4,500 6,000 - 3,100 3,400 1,760 1,000 71 678 158 Imax [A] M0 [Nm] I0 [A] 380 673 156 4,400 1PH8 main motors 572 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 346 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8224-D, (IP55) nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 1,350 92 651 154 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,400 1,760 380 651 154 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 573 Technical data and characteristics 6.1 Induction motors Table 6- 347 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8224-D, (IP55) nN PN MN IN [rpm] [kW] [Nm] [A] 1,500 92 586 142 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,600 1,760 380 678 142 1PH8 main motors 574 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 348 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8224-F, (IP55) nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 1,500 95 605 200 nmax1 nmax2 nmax3 nmax, Br [kW] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,300 1,550 485 605 200 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 575 Technical data and characteristics 6.1 Induction motors Table 6- 349 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8224-F, (IP55) nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 110 600 198 4,500 6,000 - 3,100 3,200 1,550 1,500 95 605 200 Imax [A] M0 [Nm] I0 [A] 485 600 198 4,400 1PH8 main motors 576 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 350 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8224-F, (IP55) nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 2,000 124 592 196 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,900 1,550 485 592 196 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 577 Technical data and characteristics 6.1 Induction motors Table 6- 351 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8224-F, (IP55) nN PN MN IN [rpm] [kW] [Nm] [A] 2,200 110 478 168 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,900 1,550 485 605 168 1PH8 main motors 578 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 352 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8224-L, (IP55) nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 2,500 142 542 295 nmax1 nmax2 nmax3 nmax, Br [kW] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,200 1,170 600 542 295 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 579 Technical data and characteristics 6.1 Induction motors Table 6- 353 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8224-L, (IP55) nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 2,900 149 491 270 4,500 6,000 - 3,100 3,300 1,170 2,500 142 542 295 Imax [A] M0 [Nm] I0 [A] 600 491 270 3,400 1PH8 main motors 580 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 354 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8224-L, (IP55) nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 3,400 85 239 168 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,600 1,170 600 239 168 Note: In this electrical version (L winding), supplementary losses that are disproportionately high relative to the speed occur at high connection voltages (480 V 3AC), depending on the modulation depth of the converter. To comply with the permissible motor temperature, a power reduction must be considered in the configuration. 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 581 Technical data and characteristics 6.1 Induction motors Table 6- 355 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8226-B, (IP55) nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 400 39.2 936 112 nmax1 nmax2 nmax3 nmax, Br [kW] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,500 2,300 280 936 112 1PH8 main motors 582 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 356 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8226-B, (IP55) nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 500 49 936 110 400 39 936 112 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,600 2,300 280 936 110 3,500 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 583 Technical data and characteristics 6.1 Induction motors Table 6- 357 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8226-B, (IP55) nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 600 59 939 110 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,700 2,300 280 939 110 1PH8 main motors 584 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 358 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8226-B, (IP55) nN PN MN IN [rpm] [kW] [Nm] [A] 700 68 928 108 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,800 2,300 280 936 108 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 585 Technical data and characteristics 6.1 Induction motors Table 6- 359 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8226-C, (IP55) nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 700 68 928 162 nmax1 nmax2 nmax3 nmax, Br [kW] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,100 2,300 380 928 162 1PH8 main motors 586 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 360 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8226-C, (IP55) nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 800 73 872 154 700 68 928 162 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,600 2,300 380 872 154 4,300 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 587 Technical data and characteristics 6.1 Induction motors Table 6- 361 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8226-C, (IP55) nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 1,000 92 879 156 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,900 2,300 380 879 156 1PH8 main motors 588 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 362 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8226-C, (IP55) nN PN MN IN [rpm] [kW] [Nm] [A] 1,100 101 877 154 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,900 2,300 380 928 154 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 589 Technical data and characteristics 6.1 Induction motors Table 6- 363 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8226-D, (IP55) nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 1,000 92 879 194 nmax1 nmax2 nmax3 nmax, Br [kW] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,300 2,300 485 879 194 1PH8 main motors 590 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 364 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8226-D, (IP55) nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,150 105 872 192 4,500 6,000 - 3,100 3,400 2,300 1,000 92 879 194 Imax [A] M0 [Nm] I0 [A] 485 872 192 5,800 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 591 Technical data and characteristics 6.1 Induction motors Table 6- 365 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8226-D, (IP55) nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 1,350 120 849 188 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,400 2,300 485 849 188 1PH8 main motors 592 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 366 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8226-D, (IP55) nN PN MN IN [rpm] [kW] [Nm] [A] 1,500 120 764 174 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,600 2,300 485 879 174 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 593 Technical data and characteristics 6.1 Induction motors Table 6- 367 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8226-F, (IP55) nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 1,500 130 828 270 nmax1 nmax2 nmax3 nmax, Br [kW] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,300 1,850 570 828 270 1PH8 main motors 594 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 368 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8226-F, (IP55) nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 135 737 250 4,500 6,000 - 3,100 3,300 1,850 1,500 130 828 270 Imax [A] M0 [Nm] I0 [A] 570 737 250 3,500 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 595 Technical data and characteristics 6.1 Induction motors Table 6- 369 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8226-F, (IP55) nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 2,000 153 731 245 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,100 1,850 570 731 245 1PH8 main motors 596 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 370 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8226-F, (IP55) nN PN MN IN [rpm] [kW] [Nm] [A] 2,200 130 564 205 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,100 1,850 570 828 205 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 597 Technical data and characteristics 6.1 Induction motors Table 6- 371 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8226-L, (IP55) nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 2,500 168 642 350 nmax1 nmax2 nmax3 nmax, Br [kW] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,200 1,450 740 642 350 1PH8 main motors 598 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 372 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8226-L, (IP55) nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 2,900 185 609 335 4,500 6,000 - 3,100 3,300 1,450 2,500 168 642 350 Imax [A] M0 [Nm] I0 [A] 740 609 335 3,500 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 599 Technical data and characteristics 6.1 Induction motors Table 6- 373 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8226-L, (IP55) nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 3,400 90 253 205 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,600 1,450 740 253 205 Note: In this electrical version (L winding), supplementary losses that are disproportionately high relative to the speed occur at high connection voltages (480 V 3AC), depending on the modulation depth of the converter. To comply with the permissible motor temperature, a power reduction must be considered in the configuration. 1PH8 main motors 600 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 374 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8228-B, (IP55) nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 400 48 1,146 132 nmax1 nmax2 nmax3 nmax, Br [kW] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,600 2,750 315 1,146 132 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 601 Technical data and characteristics 6.1 Induction motors Table 6- 375 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8228-B, (IP55) nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 500 60 1,146 132 400 48 1,146 132 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,700 2,750 315 1,146 132 3,600 1PH8 main motors 602 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 376 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8228-B, (IP55) nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 600 72 1,146 130 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,800 2,750 315 1,146 130 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 603 Technical data and characteristics 6.1 Induction motors Table 6- 377 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8228-B, (IP55) nN PN MN IN [rpm] [kW] [Nm] [A] 700 84 1,146 130 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,900 2,750 315 1,146 130 1PH8 main motors 604 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 378 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8228-C, (IP55) nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 700 82 1,119 188 nmax1 nmax2 nmax3 nmax, Br [kW] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,300 2,750 445 1,119 188 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 605 Technical data and characteristics 6.1 Induction motors Table 6- 379 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8228-C, (IP55) nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 800 92 1,098 182 700 82 1,119 188 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,800 2,750 445 1,098 182 4,300 1PH8 main motors 606 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 380 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8228-C, (IP55) nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 1,000 115 1,098 182 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,000 2,750 445 1,098 182 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 607 Technical data and characteristics 6.1 Induction motors Table 6- 381 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8228-C, (IP55) nN PN MN IN [rpm] [kW] [Nm] [A] 1,100 126 1,094 182 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,000 2,750 445 1,119 182 1PH8 main motors 608 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 382 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8228-D, (IP55) nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 1,000 113 1,079 235 nmax1 nmax2 nmax3 nmax, Br [kW] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,300 2,750 570 1,079 235 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 609 Technical data and characteristics 6.1 Induction motors Table 6- 383 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8228-D, (IP55) nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,150 129 1,071 235 4,500 6,000 - 3,100 3,400 2,750 1,000 113 1,079 235 Imax [A] M0 [Nm] I0 [A] 570 1,071 235 4,200 1PH8 main motors 610 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 384 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8228-D, (IP55) nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 1,350 147 1,040 225 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,400 2,750 570 1,040 225 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 611 Technical data and characteristics 6.1 Induction motors Table 6- 385 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8228-D, (IP55) nN PN MN IN [rpm] [kW] [Nm] [A] 1,500 147 936 210 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,600 2,750 570 1,079 210 1PH8 main motors 612 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 386 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8228-F, (IP55) nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 1,500 160 1,019 340 nmax1 nmax2 nmax3 nmax, Br [kW] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,300 2,450 750 1,019 340 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 613 Technical data and characteristics 6.1 Induction motors Table 6- 387 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8228-F, (IP55) nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 179 977 330 4,500 6,000 - 3,100 3,400 2,450 1,500 160 1,019 340 Imax [A] M0 [Nm] I0 [A] 750 977 330 4,200 1PH8 main motors 614 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 388 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8228-F, (IP55) nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 2,000 196 936 325 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,200 2,450 750 936 325 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 615 Technical data and characteristics 6.1 Induction motors Table 6- 389 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8228-F, (IP55) nN PN MN IN [rpm] [kW] [Nm] [A] 2,200 170 738 275 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,200 2,450 750 1,019 275 1PH8 main motors 616 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 390 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8228-L, (IP55) nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 2,500 205 783 420 nmax1 nmax2 nmax3 nmax, Br [kW] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,200 1,750 880 783 420 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 617 Technical data and characteristics 6.1 Induction motors Table 6- 391 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8228-L, (IP55) nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 2,900 215 708 390 4,500 6,000 - 3,100 3,300 1,750 2,500 205 783 420 Imax [A] M0 [Nm] I0 [A] 880 708 390 3,400 1PH8 main motors 618 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 392 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8228-L, (IP55) nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 3,400 95 267 225 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,600 1,750 880 267 225 Note: In this electrical version (L winding), supplementary losses that are disproportionately high relative to the speed occur at high connection voltages (480 V 3AC), depending on the modulation depth of the converter. To comply with the permissible motor temperature, a power reduction must be considered in the configuration. 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 619 Technical data and characteristics 6.1 Induction motors 6.1.2.9 Shaft height 225 - forced ventilation (open-circuit ventilation) Table 6- 393 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8224-B, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 400 45 1,074 Irated nmax1 nmax2 nmax3 nmax, Br [A] [kW] [rpm] [rpm] [rpm] 114 4,500 - - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,800 1,760 200 1,074 114 1PH8 main motors 620 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 394 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8224-B, (IP23) nrated Prated Mrated Irated nmax1 nmax2 nmax3 [rpm] [kW] [Nm] 500 55 1,051 400 45 1,074 114 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 112 4,500 - - 3,100 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,800 1,760 200 1,051 112 2,200 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 621 Technical data and characteristics 6.1 Induction motors Table 6- 395 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8224-B, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 600 67 1,066 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 118 4,500 - - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,800 1,760 200 1,066 118 1PH8 main motors 622 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 396 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8224-B, (IP23) nN PN MN IN nmax1 nmax2 nmax3 [rpm] [kW] [Nm] 700 67 914 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 98 4,500 - - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,300 1,760 200 1,074 98 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 623 Technical data and characteristics 6.1 Induction motors Table 6- 397 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8224-C, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 700 80 1,091 Irated nmax1 nmax2 nmax3 nmax, Br [A] [kW] [rpm] [rpm] [rpm] 188 4,500 - - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 1,760 300 1,091 188 1PH8 main motors 624 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 398 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8224-C, (IP23) nrated Prated Mrated Irated nmax1 nmax2 nmax3 [rpm] [kW] [Nm] 800 90 1,074 700 80 1,091 188 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 184 4,500 - - 3,100 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,300 1,760 300 1,074 184 3,000 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 625 Technical data and characteristics 6.1 Induction motors Table 6- 399 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8224-C, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 1,000 105 1,003 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 174 4,500 - - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,300 1,760 300 1,003 174 1PH8 main motors 626 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 400 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8224-C, (IP23) nN PN MN [rpm] [kW] [Nm] 1,100 105 912 IN nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 160 4,500 - - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,500 1,760 300 1,091 160 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 627 Technical data and characteristics 6.1 Induction motors Table 6- 401 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8224-D, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 1,000 105 1,003 Irated nmax1 nmax2 nmax3 nmax, Br [A] [kW] [rpm] [rpm] [rpm] 220 4,500 - - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,700 1,760 385 1,003 2,200 1PH8 main motors 628 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 402 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8224-D, (IP23) nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,150 120 997 220 4,500 - - 3,100 2,900 1,760 1,000 105 1,003 220 Imax [A] M0 [Nm] I0 [A] 385 997 220 3,700 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 629 Technical data and characteristics 6.1 Induction motors Table 6- 403 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8224-D, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 1,350 137 969 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 215 4,500 - - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,000 1,760 385 969 215 1PH8 main motors 630 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 404 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8224-D, (IP23) nN PN MN [rpm] [kW] [Nm] 1,500 137 872 IN nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 194 4,500 - - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,400 1,760 385 1,003 194 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 631 Technical data and characteristics 6.1 Induction motors Table 6- 405 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8224-F, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 1,500 142 904 Irated nmax1 nmax2 nmax3 nmax, Br [A] [kW] [rpm] [rpm] [rpm] 290 4,500 - - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,000 1,550 490 904 290 1PH8 main motors 632 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 406 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8224-F, (IP23) nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 165 900 285 4,500 - - 3,100 2,900 1,550 1,500 142 904 290 Imax [A] M0 [Nm] I0 [A] 490 900 285 4,500 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 633 Technical data and characteristics 6.1 Induction motors Table 6- 407 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8224-F, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 2,000 178 850 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 265 4,500 - - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,900 1,550 490 850 265 1PH8 main motors 634 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 408 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8224-F, (IP23) nN PN MN [rpm] [kW] [Nm] 2,200 178 773 IN nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 250 4,500 - - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,900 1,550 490 904 250 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 635 Technical data and characteristics 6.1 Induction motors Table 6- 409 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8224-L, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 2,500 178 680 Irated nmax1 nmax2 nmax3 nmax, Br [A] [kW] [rpm] [rpm] [rpm] 355 4,500 - - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,500 1,170 600 680 355 1PH8 main motors 636 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 410 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8224-L, (IP23) nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 2,900 205 675 355 4,500 - - 3,100 3,500 1,170 2,500 178 680 355 Imax [A] M0 [Nm] I0 [A] 600 675 355 3,900 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 637 Technical data and characteristics 6.1 Induction motors Table 6- 411 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8224-L, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 3,400 205 576 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 310 4,500 - - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,500 1,170 600 576 310 1PH8 main motors 638 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 412 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8226-B, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 400 57 1,361 Irated nmax1 nmax2 nmax3 nmax, Br [A] [kW] [rpm] [rpm] [rpm] 144 4,500 - - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,100 2,300 255 1,361 144 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 639 Technical data and characteristics 6.1 Induction motors Table 6- 413 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8226-B, (IP23) nrated Prated Mrated Irated nmax1 nmax2 nmax3 [rpm] [kW] [Nm] 500 72 1,375 400 57 1,361 144 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 144 4,500 - - 3,100 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 2,300 255 1,375 144 2,800 1PH8 main motors 640 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 414 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8226-B, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 600 87 1,385 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 152 4,500 - - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,300 2,300 255 1,385 152 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 641 Technical data and characteristics 6.1 Induction motors Table 6- 415 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8226-B, (IP23) nN PN MN [rpm] [kW] [Nm] 700 87 1,187 IN nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 128 4,500 - - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,400 2,300 255 1,361 128 1PH8 main motors 642 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 416 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8226-C, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 700 106 1,446 Irated nmax1 nmax2 nmax3 nmax, Br [A] [kW] [rpm] [rpm] [rpm] 240 4,500 - - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 2,300 395 1,446 240 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 643 Technical data and characteristics 6.1 Induction motors Table 6- 417 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8226-C, (IP23) nrated Prated Mrated Irated nmax1 nmax2 nmax3 [rpm] [kW] [Nm] 800 118 1,409 700 106 1,446 240 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 235 4,500 - - 3,100 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,300 2,300 395 1,409 235 2,900 1PH8 main motors 644 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 418 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8226-C, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 1,000 146 1,394 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 230 4,500 - - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,300 2,300 395 1,394 230 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 645 Technical data and characteristics 6.1 Induction motors Table 6- 419 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8226-C, (IP23) nN PN MN [rpm] [kW] [Nm] 1,100 146 1,268 IN nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 205 4,500 - - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,500 2,300 395 1,446 205 1PH8 main motors 646 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 420 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8226-D, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 1,000 135 1,289 Irated nmax1 nmax2 nmax3 nmax, Br [A] [kW] [rpm] [rpm] [rpm] 275 4,500 - - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,700 2,300 490 1,289 275 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 647 Technical data and characteristics 6.1 Induction motors Table 6- 421 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8226-D, (IP23) nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,150 155 1,287 270 4,500 - - 3,100 2,800 2,300 1,000 135 1,289 275 Imax [A] M0 [Nm] I0 [A] 490 1,287 270 3,600 1PH8 main motors 648 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 422 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8226-D, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 1,350 172 1,217 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 255 4,500 - - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,900 2,300 490 1,217 255 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 649 Technical data and characteristics 6.1 Induction motors Table 6- 423 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8226-D, (IP23) nN PN MN [rpm] [kW] [Nm] 1,500 172 1,095 IN nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 240 4,500 - - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,100 2,300 490 1,289 240 1PH8 main motors 650 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 424 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8226-F, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 1,500 175 1,114 Irated nmax1 nmax2 nmax3 nmax, Br [A] [kW] [rpm] [rpm] [rpm] 350 4,500 - - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,000 1,850 580 1,114 350 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 651 Technical data and characteristics 6.1 Induction motors Table 6- 425 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8226-F, (IP23) nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 200 1,091 350 4,500 - - 3,100 2,900 1,850 1,500 175 1,114 350 Imax [A] M0 [Nm] I0 [A] 580 1,091 350 4,500 1PH8 main motors 652 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 426 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8226-F, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 2,000 220 1,051 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 335 4,500 - - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,900 1,850 580 1,051 335 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 653 Technical data and characteristics 6.1 Induction motors Table 6- 427 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8226-F, (IP23) nN PN MN [rpm] [kW] [Nm] 2,200 220 955 IN nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 305 4,500 - - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,900 1,850 580 1,114 305 1PH8 main motors 654 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 428 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8226-L, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 2,500 235 898 Irated nmax1 nmax2 nmax3 nmax, Br [A] [kW] [rpm] [rpm] [rpm] 475 4,500 - - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,500 1,450 750 898 475 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 655 Technical data and characteristics 6.1 Induction motors Table 6- 429 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8226-L, (IP23) nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 2,900 270 889 470 4,500 - - 3,100 3,500 1,450 2,500 235 898 475 Imax [A] M0 [Nm] I0 [A] 750 889 470 3,900 1PH8 main motors 656 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 430 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8226-L, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 3,400 270 758 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 405 4,500 - - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,500 1,450 750 758 405 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 657 Technical data and characteristics 6.1 Induction motors Table 6- 431 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8228-B, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 400 72 1,719 Irated nmax1 nmax2 nmax3 nmax, Br [A] [kW] [rpm] [rpm] [rpm] 176 4,500 - - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 2,750 300 1,719 176 1PH8 main motors 658 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 432 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8228-B, (IP23) nrated Prated Mrated Irated nmax1 nmax2 nmax3 [rpm] [kW] [Nm] 500 90 1,719 400 72 1,719 176 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 174 4,500 - - 3,100 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 2,750 300 1,719 174 2,900 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 659 Technical data and characteristics 6.1 Induction motors Table 6- 433 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8228-B, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 600 108 1,719 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 188 4,500 - - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 2,750 300 1,719 188 1PH8 main motors 660 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 434 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8228-B, (IP23) nN PN MN [rpm] [kW] [Nm] 700 108 1,473 IN nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 156 4,500 - - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,500 2,750 300 1,719 156 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 661 Technical data and characteristics 6.1 Induction motors Table 6- 435 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8228-C, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 700 120 1,637 Irated nmax1 nmax2 nmax3 nmax, Br [A] [kW] [rpm] [rpm] [rpm] 265 4,500 - - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,300 2,750 450 1,637 265 1PH8 main motors 662 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 436 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8228-C, (IP23) nrated Prated Mrated Irated nmax1 nmax2 nmax3 [rpm] [kW] [Nm] 800 135 1,612 700 120 1,637 265 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 260 4,500 - - 3,100 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,400 2,750 450 1,612 260 3,100 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 663 Technical data and characteristics 6.1 Induction motors Table 6- 437 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8228-C, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 1,000 165 1,576 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 250 4,500 - - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,400 2,750 450 1,576 250 1PH8 main motors 664 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 438 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8228-C, (IP23) nN PN MN [rpm] [kW] [Nm] 1,100 165 1,433 IN nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 225 4,500 - - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,700 2,750 450 1,637 225 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 665 Technical data and characteristics 6.1 Induction motors Table 6- 439 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8228-D, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 1,000 165 1,576 Irated nmax1 nmax2 nmax3 nmax, Br [A] [kW] [rpm] [rpm] [rpm] 330 4,500 - - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,700 2,750 580 1,576 330 1PH8 main motors 666 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 440 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8228-D, (IP23) nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,150 190 1,578 330 4,500 - - 3,100 2,800 2,750 1,000 165 1,576 330 Imax [A] M0 [Nm] I0 [A] 580 1,578 330 3,600 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 667 Technical data and characteristics 6.1 Induction motors Table 6- 441 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8228-D, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 1,350 218 1,542 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 320 4,500 - - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,800 2,750 580 1,542 320 1PH8 main motors 668 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 442 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8228-D, (IP23) nN PN MN [rpm] [kW] [Nm] 1,500 218 1,388 IN nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 295 4,500 - - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,000 2,750 580 1,576 295 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 669 Technical data and characteristics 6.1 Induction motors Table 6- 443 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8228-F, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 1,500 230 1,464 Irated nmax1 nmax2 nmax3 nmax, Br [A] [kW] [rpm] [rpm] [rpm] 465 4,500 - - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,000 2,450 760 1,464 465 1PH8 main motors 670 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 444 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8228-F, (IP23) nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 265 1,446 460 4,500 - - 3,100 2,900 2,450 1,500 230 1,464 465 Imax [A] M0 [Nm] I0 [A] 760 1,446 460 4,000 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 671 Technical data and characteristics 6.1 Induction motors Table 6- 445 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8228-F, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 2,000 288 1,375 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 440 4,500 - - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,900 2,450 760 1,375 440 1PH8 main motors 672 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 446 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8228-F, (IP23) nN PN MN [rpm] [kW] [Nm] 2,200 288 1,250 IN nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 405 4,500 - - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,900 2,450 760 1,464 405 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 673 Technical data and characteristics 6.1 Induction motors Table 6- 447 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8228-L, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 2,500 265 1,012 Irated nmax1 nmax2 nmax3 nmax, Br [A] [kW] [rpm] [rpm] [rpm] 530 4,500 - - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,500 1,750 880 1,012 530 1PH8 main motors 674 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 448 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8228-L, (IP23) nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 2,900 300 988 510 4,500 - - 3,100 3,500 1,750 2,500 265 1,012 530 Imax [A] M0 [Nm] I0 [A] 880 988 510 3,800 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 675 Technical data and characteristics 6.1 Induction motors Table 6- 449 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8228-L, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 3,400 300 843 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 450 4,500 - - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,500 1,750 880 843 450 1PH8 main motors 676 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors 6.1.2.10 Shaft height 280 - forced ventilation Table 6- 450 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8284-B1, (IP55) nrated Prated Mrated [rpm] [kW] [Nm] 400 63 1,504 Irated nmax1 nmax2 nmax3 nmax, Br [A] [kW] [rpm] [rpm] [rpm] 154 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,100 4,250 435 1,504 154 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 677 Technical data and characteristics 6.1 Induction motors Table 6- 451 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8284-B1, (IP55) nrated Prated Mrated Irated nmax1 nmax2 nmax3 [rpm] [kW] [Nm] 500 80 1,529 400 63 1,504 154 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 154 3,300 - - 2,300 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,600 4,250 435 1,529 154 2,100 1PH8 main motors 678 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 452 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8284-B1, (IP55) nrated Prated Mrated [rpm] [kW] [Nm] 600 95 1,519 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 154 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,800 4,250 435 1,519 154 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 679 Technical data and characteristics 6.1 Induction motors Table 6- 453 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8284-B1, (IP55) nN PN MN [rpm] [kW] [Nm] 700 105 1,433 IN nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 150 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,400 4,250 435 1,504 150 1PH8 main motors 680 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 454 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8284-C1, (IP55) nrated Prated Mrated [rpm] [kW] [Nm] 700 110 1,501 Irated nmax1 nmax2 nmax3 nmax, Br [A] [kW] [rpm] [rpm] [rpm] 240 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,100 4,250 660 1,501 240 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 681 Technical data and characteristics 6.1 Induction motors Table 6- 455 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8284-C1, (IP55) nrated Prated Mrated Irated nmax1 nmax2 nmax3 [rpm] [kW] [Nm] 800 125 1,492 700 110 1,501 240 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 235 3,300 - - 2,300 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,300 4,250 660 1,492 235 3,000 1PH8 main motors 682 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 456 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8284-C1, (IP55) nrated Prated Mrated [rpm] [kW] [Nm] 1,000 150 1,433 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 230 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,300 4,250 660 1,433 230 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 683 Technical data and characteristics 6.1 Induction motors Table 6- 457 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8284-C1, (IP55) nN PN MN [rpm] [kW] [Nm] 1,100 155 1,346 IN nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 220 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,400 4,250 660 1,501 220 1PH8 main motors 684 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 458 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8284-D1, (IP55) nrated Prated Mrated [rpm] [kW] [Nm] 1,000 150 1,433 Irated nmax1 nmax2 nmax3 nmax, Br [A] [kW] [rpm] [rpm] [rpm] 315 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,100 4,150 870 1,433 315 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 685 Technical data and characteristics 6.1 Induction motors Table 6- 459 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8284-D1, (IP55) nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,150 170 1,414 310 3,300 - - 2,300 2,200 4,150 1,000 150 1,433 315 Imax [A] M0 [Nm] I0 [A] 870 1,414 310 3,300 1PH8 main motors 686 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 460 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8284-D1, (IP55) nrated Prated Mrated [rpm] [kW] [Nm] 1,350 200 1,416 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 315 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 4,150 870 1,416 315 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 687 Technical data and characteristics 6.1 Induction motors Table 6- 461 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8284-D1, (IP55) nN PN MN [rpm] [kW] [Nm] 1,500 200 1,273 IN nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 290 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 4,150 870 1,433 290 1PH8 main motors 688 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 462 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8284-F1, (IP55) nrated Prated Mrated [rpm] [kW] [Nm] 1,500 196 1,248 Irated nmax1 nmax2 nmax3 nmax, Br [A] [kW] [rpm] [rpm] [rpm] 390 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,900 3,650 1,100 1,248 390 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 689 Technical data and characteristics 6.1 Induction motors Table 6- 463 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8284-F1, (IP55) nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 225 1,228 390 3,300 - - 2,300 2,200 3,650 1,500 196 1,248 390 Imax [A] M0 [Nm] I0 [A] 1,100 1,228 390 3,100 1PH8 main motors 690 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 464 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8284-F1, (IP55) nrated Prated Mrated [rpm] [kW] [Nm] 2,000 255 1,218 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 390 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 3,650 1,100 1,218 390 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 691 Technical data and characteristics 6.1 Induction motors Table 6- 465 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8284-F1, (IP55) nN PN MN [rpm] [kW] [Nm] 2,200 230 998 IN nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 330 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,400 3,650 1,100 1,248 330 1PH8 main motors 692 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 466 SINAMICS, 3-ph. 690 VAC, Basic Line Module, (BLM), 1PH8284-H1, (IP55) nrated Prated Mrated [rpm] [kW] [Nm] 400 61 1,456 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 82 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,100 4,100 220 1,456 82 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 693 Technical data and characteristics 6.1 Induction motors Table 6- 467 SINAMICS, 3-ph. 690 VAC, Active Line Module, (ALM), 1PH8284-H1, (IP55) nrated Prated Mrated Irated nmax1 nmax2 nmax3 [rpm] [kW] [Nm] 500 77 1,471 400 61 1,456 82 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 82 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,600 4,100 220 1,471 82 2,200 1PH8 main motors 694 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 468 SINAMICS, 3-ph. 690 VAC, Basic Line Module, (BLM), 1PH8284-K1, (IP55) nrated Prated Mrated [rpm] [kW] [Nm] 700 100 1,364 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 118 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,100 4,100 340 1,364 118 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 695 Technical data and characteristics 6.1 Induction motors Table 6- 469 SINAMICS, 3-ph. 690 VAC, Active Line Module, (ALM), 1PH8284-K1, (IP55) nrated Prated Mrated Irated nmax1 nmax2 nmax3 [rpm] [kW] [Nm] 800 115 1,373 700 100 1,364 118 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 120 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,300 4,100 340 1,373 120 3,000 1PH8 main motors 696 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 470 SINAMICS, 3-ph. 690 VAC, Basic Line Module, (BLM), 1PH8284-U1, (IP55) nrated Prated Mrated [rpm] [kW] [Nm] 1,000 143 1,366 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 176 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,100 4,000 465 1,366 176 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 697 Technical data and characteristics 6.1 Induction motors Table 6- 471 SINAMICS, 3-ph. 690 VAC, Active Line Module, (ALM), 1PH8284-U1, (IP55) nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,150 164 1,362 174 3,300 - - 2,300 2,200 4,000 1,000 143 1,366 176 Imax [A] M0 [Nm] I0 [A] 465 1,362 174 3,100 1PH8 main motors 698 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 472 SINAMICS, 3-ph. 690 VAC, Basic Line Module, (BLM), 1PH8284-W1, (IP55) nrated Prated Mrated [rpm] [kW] [Nm] 1,500 186 1,184 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 220 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,900 3,550 620 1,184 220 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 699 Technical data and characteristics 6.1 Induction motors Table 6- 473 SINAMICS, 3-ph. 690 VAC, Active Line Module, (ALM), 1PH8284-W1, (IP55) nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 217 1,184 220 3,300 - - 2,300 2,200 3,550 1,500 186 1,184 220 Imax [A] M0 [Nm] I0 [A] 620 1,184 220 3,300 1PH8 main motors 700 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 474 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8286-B1, (IP55) nrated Prated Mrated [rpm] [kW] [Nm] 400 80 1,910 Irated nmax1 nmax2 nmax3 nmax, Br [A] [kW] [rpm] [rpm] [rpm] 186 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,200 5,350 530 1,910 186 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 701 Technical data and characteristics 6.1 Induction motors Table 6- 475 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8286-B1, (IP55) nrated Prated Mrated Irated nmax1 nmax2 nmax3 [rpm] [kW] [Nm] 500 100 1,909 400 80 1,910 186 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 188 3,300 - - 2,300 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,600 5,350 530 1,909 188 2,100 1PH8 main motors 702 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 476 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8286-B1, (IP55) nrated Prated Mrated [rpm] [kW] [Nm] 600 120 1,916 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 188 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,800 5,350 530 1,916 188 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 703 Technical data and characteristics 6.1 Induction motors Table 6- 477 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8286-B1, (IP55) nN PN MN [rpm] [kW] [Nm] 700 132 1,801 IN nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 184 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,500 5,350 530 1,910 184 1PH8 main motors 704 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 478 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8286-C1, (IP55) nrated Prated Mrated [rpm] [kW] [Nm] 700 138 1,883 Irated nmax1 nmax2 nmax3 nmax, Br [A] [kW] [rpm] [rpm] [rpm] 295 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,100 5,250 800 1,883 295 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 705 Technical data and characteristics 6.1 Induction motors Table 6- 479 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8286-C1, (IP55) nrated Prated Mrated Irated nmax1 nmax2 nmax3 [rpm] [kW] [Nm] 800 155 1,850 700 138 1,883 295 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 285 3,300 - - 2,300 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,300 5,250 800 1,850 285 3,000 1PH8 main motors 706 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 480 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8286-C1, (IP55) nrated Prated Mrated [rpm] [kW] [Nm] 1,000 185 1,767 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 280 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,300 5,250 800 1,767 280 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 707 Technical data and characteristics 6.1 Induction motors Table 6- 481 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8286-C1, (IP55) nN PN MN [rpm] [kW] [Nm] 1,100 191 1,658 IN nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 270 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,400 5,250 800 1,883 270 1PH8 main motors 708 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 482 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8286-D1, (IP55) nrated Prated Mrated [rpm] [kW] [Nm] 1,000 182 1,738 Irated nmax1 nmax2 nmax3 nmax, Br [A] [kW] [rpm] [rpm] [rpm] 410 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,100 5,150 1,080 1,738 410 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 709 Technical data and characteristics 6.1 Induction motors Table 6- 483 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8286-D1, (IP55) nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,150 210 1,745 410 3,300 - - 2,300 2,200 5,150 1,000 182 1,738 410 Imax [A] M0 [Nm] I0 [A] 1,080 1,745 410 3,300 1PH8 main motors 710 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 484 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8286-D1, (IP55) nrated Prated Mrated [rpm] [kW] [Nm] 1,350 245 1,733 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 410 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 5,150 1,080 1,733 410 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 711 Technical data and characteristics 6.1 Induction motors Table 6- 485 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8286-D1, (IP55) nN PN MN [rpm] [kW] [Nm] 1,500 245 1,560 IN nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 380 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 5,150 1,080 1,738 380 1PH8 main motors 712 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 486 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8286-F1, (IP55) nrated Prated Mrated [rpm] [kW] [Nm] 1,500 250 1,592 Irated nmax1 nmax2 nmax3 nmax, Br [A] [kW] [rpm] [rpm] [rpm] 490 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,000 4,500 1,360 1,592 490 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 713 Technical data and characteristics 6.1 Induction motors Table 6- 487 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8286-F1, (IP55) nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 270 1,474 460 3,300 - - 2,300 2,200 4,500 1,500 250 1,592 490 Imax [A] M0 [Nm] I0 [A] 1,360 1,474 460 2,700 1PH8 main motors 714 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 488 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8286-F1, (IP55) nrated Prated Mrated [rpm] [kW] [Nm] 2,000 310 1,481 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 460 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 4,500 1,360 1,481 460 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 715 Technical data and characteristics 6.1 Induction motors Table 6- 489 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8286-F1, (IP55) nN PN MN [rpm] [kW] [Nm] 2,200 279 1,211 IN nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 395 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,400 4,500 1,360 1,592 395 1PH8 main motors 716 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 490 SINAMICS, 3-ph. 690 VAC, Basic Line Module, (BLM), 1PH8286-H1, (IP55) nrated Prated Mrated [rpm] [kW] [Nm] 400 77 1,838 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 100 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,200 5,100 275 1,838 100 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 717 Technical data and characteristics 6.1 Induction motors Table 6- 491 SINAMICS, 3-ph. 690 VAC, Active Line Module, (ALM), 1PH8286-H1, (IP55) nrated Prated Mrated Irated nmax1 nmax2 nmax3 [rpm] [kW] [Nm] 500 96 1,834 400 77 1,838 100 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 100 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,600 5,100 275 1,834 100 2,200 1PH8 main motors 718 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 492 SINAMICS, 3-ph. 690 VAC, Basic Line Module, (BLM), 1PH8286-K1, (IP55) nrated Prated Mrated [rpm] [kW] [Nm] 700 127 1,733 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 158 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,100 5,100 410 1,733 158 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 719 Technical data and characteristics 6.1 Induction motors Table 6- 493 SINAMICS, 3-ph. 690 VAC, Active Line Module, (ALM), 1PH8286-K1, (IP55) nrated Prated Mrated Irated nmax1 nmax2 nmax3 [rpm] [kW] [Nm] 800 145 1,731 700 127 1,733 158 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 158 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,300 5,100 410 1,731 158 3,200 1PH8 main motors 720 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 494 SINAMICS, 3-ph. 690 VAC, Basic Line Module, (BLM), 1PH8286-U1, (IP55) nrated Prated Mrated [rpm] [kW] [Nm] 1,000 176 1,681 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 230 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,100 5,000 610 1,681 230 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 721 Technical data and characteristics 6.1 Induction motors Table 6- 495 SINAMICS, 3-ph. 690 VAC, Active Line Module, (ALM), 1PH8286-U1, (IP55) nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,150 203 1,686 230 3,300 - - 2,300 2,200 5,000 1,000 176 1,681 230 Imax [A] M0 [Nm] I0 [A] 610 1,686 230 3,300 1PH8 main motors 722 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 496 SINAMICS, 3-ph. 690 VAC, Basic Line Module, (BLM), 1PH8286-W1, (IP55) nrated Prated Mrated [rpm] [kW] [Nm] 1,500 224 1,426 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 260 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,000 4,350 760 1,426 260 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 723 Technical data and characteristics 6.1 Induction motors Table 6- 497 SINAMICS, 3-ph. 690 VAC, Active Line Module, (ALM), 1PH8286-W1, (IP55) nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 261 1,424 260 3,300 - - 2,300 2,200 4,350 1,500 224 1,426 260 Imax [A] M0 [Nm] I0 [A] 760 1,424 260 3,300 1PH8 main motors 724 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 498 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8288-B1, (IP55) nrated Prated Mrated [rpm] [kW] [Nm] 400 103 2,459 Irated nmax1 nmax2 nmax3 nmax, Br [A] [kW] [rpm] [rpm] [rpm] 245 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,300 6,550 650 2,459 245 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 725 Technical data and characteristics 6.1 Induction motors Table 6- 499 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8288-B1, (IP55) nrated Prated Mrated Irated nmax1 nmax2 nmax3 [rpm] [kW] [Nm] 500 130 2,481 400 104 2,481 245 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 245 3,300 - - 2,300 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,600 6,550 650 2,481 245 2,100 1PH8 main motors 726 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 500 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8288-B1, (IP55) nrated Prated Mrated [rpm] [kW] [Nm] 600 155 2,474 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 245 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,800 6,550 650 2,474 245 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 727 Technical data and characteristics 6.1 Induction motors Table 6- 501 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8288-B1, (IP55) nN PN MN [rpm] [kW] [Nm] 700 165 2,251 IN nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 230 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,600 6,550 650 2,459 230 1PH8 main motors 728 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 502 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8288-C1, (IP55) nrated Prated Mrated [rpm] [kW] [Nm] 700 166 2,265 Irated nmax1 nmax2 nmax3 nmax, Br [A] [kW] [rpm] [rpm] [rpm] 365 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,100 6,450 970 2,265 365 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 729 Technical data and characteristics 6.1 Induction motors Table 6- 503 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8288-C1, (IP55) nrated Prated Mrated Irated nmax1 nmax2 nmax3 [rpm] [kW] [Nm] 800 190 2,268 700 166 2,268 365 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 365 3,300 - - 2,300 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,300 6,450 970 2,268 365 3,100 1PH8 main motors 730 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 504 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8288-C1, (IP55) nrated Prated Mrated [rpm] [kW] [Nm] 1,000 230 2,197 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 355 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,300 6,450 970 2,197 355 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 731 Technical data and characteristics 6.1 Induction motors Table 6- 505 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8288-C1, (IP55) nN PN MN [rpm] [kW] [Nm] 1,100 238 2,066 IN nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 345 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,400 6,450 970 2,265 345 1PH8 main motors 732 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 506 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8288-D1, (IP55) nrated Prated Mrated [rpm] [kW] [Nm] 1,000 226 2,158 Irated nmax1 nmax2 nmax3 nmax, Br [A] [kW] [rpm] [rpm] [rpm] 495 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,100 6,350 1,300 2,158 495 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 733 Technical data and characteristics 6.1 Induction motors Table 6- 507 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8288-D1, (IP55) nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,150 260 2,160 495 3,300 - - 2,300 2,200 6,350 1,000 226 2,160 495 Imax [A] M0 [Nm] I0 [A] 1,300 2,160 495 3,300 1PH8 main motors 734 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 508 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8288-D1, (IP55) nrated Prated Mrated [rpm] [kW] [Nm] 1,350 305 2,158 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 495 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 6,350 1,300 2,158 495 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 735 Technical data and characteristics 6.1 Induction motors Table 6- 509 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8288-D1, (IP55) nN PN MN [rpm] [kW] [Nm] 1,500 305 1,942 IN nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 455 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 6,350 1,300 2,158 455 1PH8 main motors 736 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 510 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8288-F1, (IP55) nrated Prated Mrated [rpm] [kW] [Nm] 1,500 320 2,037 Irated nmax1 nmax2 nmax3 nmax, Br [A] [kW] [rpm] [rpm] [rpm] 620 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,100 5,500 1,640 2,037 1,640 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 737 Technical data and characteristics 6.1 Induction motors Table 6- 511 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8288-F1, (IP55) nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 340 1,856 580 3,300 - - 2,300 2,200 5,500 1,500 292 1,856 580 Imax [A] M0 [Nm] I0 [A] 1,640 1,856 1,640 3,300 1PH8 main motors 738 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 512 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8288-F1, (IP55) nrated Prated Mrated [rpm] [kW] [Nm] 2,000 385 1,838 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 570 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 5,500 1,640 1,838 1,640 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 739 Technical data and characteristics 6.1 Induction motors Table 6- 513 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8288-F1, (IP55) nN PN MN [rpm] [kW] [Nm] 2,200 347 1,506 IN nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 495 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,400 5,500 1,640 2,037 1,640 1PH8 main motors 740 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 514 SINAMICS, 3-ph. 690 VAC, Basic Line Module, (BLM), 1PH8288-H1, (IP55) nrated Prated Mrated [rpm] [kW] [Nm] 400 100 2,388 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 130 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,300 6,300 335 2,388 130 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 741 Technical data and characteristics 6.1 Induction motors Table 6- 515 SINAMICS, 3-ph. 690 VAC, Active Line Module, (ALM), 1PH8288-H1, (IP55) nrated Prated Mrated Irated nmax1 nmax2 nmax3 [rpm] [kW] [Nm] 500 125 2,388 400 100 2,388 128 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 128 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,600 6,300 335 2,388 128 2,000 1PH8 main motors 742 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 516 SINAMICS, 3-ph. 690 VAC, Basic Line Module, (BLM), 1PH8288-K1, (IP55) nrated Prated Mrated [rpm] [kW] [Nm] 700 162 2,210 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 186 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,100 6,300 520 2,210 186 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 743 Technical data and characteristics 6.1 Induction motors Table 6- 517 SINAMICS, 3-ph. 690 VAC, Active Line Module, (ALM), 1PH8288-K1, (IP55) nrated Prated Mrated Irated nmax1 nmax2 nmax3 [rpm] [kW] [Nm] 800 185 2,208 700 162 2,208 184 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 184 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,300 6,300 520 2,208 184 3,100 1PH8 main motors 744 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 518 SINAMICS, 3-ph. 690 VAC, Basic Line Module, (BLM), 1PH8288-U1, (IP55) nrated Prated Mrated [rpm] [kW] [Nm] 1,000 218 2,082 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 275 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,100 6,250 740 2,082 275 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 745 Technical data and characteristics 6.1 Induction motors Table 6- 519 SINAMICS, 3-ph. 690 VAC, Active Line Module, (ALM), 1PH8288-U1, (IP55) nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,150 251 2,084 275 3,300 - - 2,300 2,200 6,250 1,000 218 2,084 275 Imax [A] M0 [Nm] I0 [A] 740 2,084 275 3,300 1PH8 main motors 746 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 520 SINAMICS, 3-ph. 690 VAC, Basic Line Module, (BLM), 1PH8288-W1, (IP55) nrated Prated Mrated [rpm] [kW] [Nm] 1,500 282 1,795 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 325 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,100 5,350 920 1,795 325 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 747 Technical data and characteristics 6.1 Induction motors Table 6- 521 SINAMICS, 3-ph. 690 VAC, Active Line Module, (ALM), 1PH8288-W1, (IP55) nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 329 1,795 325 3,300 - - 2,300 2,200 5,350 1,500 282 1,795 325 Imax [A] M0 [Nm] I0 [A] 920 1,795 325 3,300 1PH8 main motors 748 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors 6.1.2.11 Shaft height 280 - forced ventilation (open-circuit ventilation) Table 6- 522 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8284-C4, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 700 171 2,333 Irated nmax1 nmax2 nmax3 nmax, Br [A] [kW] [rpm] [rpm] [rpm] 355 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,200 4,250 660 2,333 355 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 749 Technical data and characteristics 6.1 Induction motors Table 6- 523 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8284-C4, (IP23) nrated Prated Mrated Irated nmax1 nmax2 nmax3 [rpm] [kW] [Nm] 800 195 2,328 700 171 2,333 355 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 335 3,300 - - 2,300 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,350 4,250 660 2,328 335 2,000 1PH8 main motors 750 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 524 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8284-C4, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 1,000 235 2,244 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 345 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,700 4,250 660 2,244 345 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 751 Technical data and characteristics 6.1 Induction motors Table 6- 525 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8284-C4, (IP23) nN PN MN [rpm] [kW] [Nm] 1,100 250 2,170 IN nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 335 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,700 4,250 660 2,333 335 1PH8 main motors 752 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 526 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8284-D4, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 1,000 243 2,321 Irated nmax1 nmax2 nmax3 nmax, Br [A] [kW] [rpm] [rpm] [rpm] 490 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,900 4,150 870 2,321 490 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 753 Technical data and characteristics 6.1 Induction motors Table 6- 527 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8284-D4, (IP23) nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,150 280 2,325 475 3,300 - - 2,300 2,200 4,150 1,000 243 2,321 490 Imax [A] M0 [Nm] I0 [A] 870 2,325 475 2,800 1PH8 main motors 754 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 528 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8284-D4, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 1,350 325 2,299 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 475 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 4,150 870 2,299 475 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 755 Technical data and characteristics 6.1 Induction motors Table 6- 529 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8284-D4, (IP23) nN PN MN [rpm] [kW] [Nm] 1,500 325 2,069 IN nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 440 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 4,150 870 2,321 440 1PH8 main motors 756 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 530 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8284-F4, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 1,500 319 2,031 Irated nmax1 nmax2 nmax3 nmax, Br [A] [kW] [rpm] [rpm] [rpm] 620 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,900 3,650 1,100 2,031 620 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 757 Technical data and characteristics 6.1 Induction motors Table 6- 531 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8284-F4, (IP23) nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 370 2,019 610 3,300 - - 2,300 2,200 3,650 1,500 319 2,031 620 Imax [A] M0 [Nm] I0 [A] 1,100 2,019 610 3,300 1PH8 main motors 758 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 532 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8284-F4, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 2,000 415 1,981 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 600 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 3,650 1,100 1,981 600 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 759 Technical data and characteristics 6.1 Induction motors Table 6- 533 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8284-F4, (IP23) nN PN MN [rpm] [kW] [Nm] 2,200 394 1710 IN nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 520 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,400 3,650 1,100 2,031 520 1PH8 main motors 760 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 534 SINAMICS, 3-ph. 690 VAC, Basic Line Module, (BLM), 1PH8284-K4, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 700 162 2,210 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 184 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,200 4,100 340 2,210 184 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 761 Technical data and characteristics 6.1 Induction motors Table 6- 535 SINAMICS, 3-ph. 690 VAC, Active Line Module, (ALM), 1PH8284-K4, (IP23) nrated Prated Mrated Irated nmax1 nmax2 nmax3 [rpm] [kW] [Nm] 800 185 2,208 700 162 2,210 184 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 182 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,500 4,100 340 2,208 182 1,800 1PH8 main motors 762 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 536 SINAMICS, 3-ph. 690 VAC, Basic Line Module, (BLM), 1PH8284-U4, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 1,000 236 2,254 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 265 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,900 4,000 465 2,254 265 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 763 Technical data and characteristics 6.1 Induction motors Table 6- 537 SINAMICS, 3-ph. 690 VAC, Active Line Module, (ALM), 1PH8284-U4, (IP23) nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,150 272 2,255 270 3,300 - - 2,300 2,200 4,000 1,000 236 2,254 265 Imax [A] M0 [Nm] I0 [A] 465 2,255 270 2,500 1PH8 main motors 764 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 538 SINAMICS, 3-ph. 690 VAC, Basic Line Module, (BLM), 1PH8284-W4, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 1,500 307 1,955 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 345 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,900 3,550 620 1,955 345 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 765 Technical data and characteristics 6.1 Induction motors Table 6- 539 SINAMICS, 3-ph. 690 VAC, Active Line Module, (ALM), 1PH8284-W4, (IP23) nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 359 1,959 345 3,300 - - 2,300 2,200 3,550 1,500 307 1,955 345 Imax [A] M0 [Nm] I0 [A] 620 1,959 345 2,600 1PH8 main motors 766 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 540 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8286-C4, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 700 219 2,988 Irated nmax1 nmax2 nmax3 nmax, Br [A] [kW] [rpm] [rpm] [rpm] 455 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,300 5,250 800 2,988 455 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 767 Technical data and characteristics 6.1 Induction motors Table 6- 541 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8286-C4, (IP23) nrated Prated Mrated Irated nmax1 nmax2 nmax3 [rpm] [kW] [Nm] 800 250 2,984 700 219 2,988 455 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 435 3,300 - - 2,300 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,500 5,250 800 2,984 435 2,100 1PH8 main motors 768 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 542 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8286-C4, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 1,000 310 2,961 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 450 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,000 5,250 800 2,961 450 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 769 Technical data and characteristics 6.1 Induction motors Table 6- 543 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8286-C4, (IP23) nN PN MN [rpm] [kW] [Nm] 1,100 330 2,865 IN nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 440 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,000 5,250 800 2,988 440 1PH8 main motors 770 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 544 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8286-D4, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 1,000 309 2,951 Irated nmax1 nmax2 nmax3 nmax, Br [A] [kW] [rpm] [rpm] [rpm] 630 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,000 5,150 1,080 2,951 630 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 771 Technical data and characteristics 6.1 Induction motors Table 6- 545 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8286-D4, (IP23) nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,150 355 2,944 630 3,300 - - 2,300 2,200 5,150 1,000 309 2,951 630 Imax [A] M0 [Nm] I0 [A] 1,080 2,944 630 3,300 1PH8 main motors 772 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 546 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8286-D4, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 1,350 410 2,901 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 620 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 5,150 1,080 2,901 620 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 773 Technical data and characteristics 6.1 Induction motors Table 6- 547 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8286-D4, (IP23) nN PN MN [rpm] [kW] [Nm] 1,500 410 2,610 IN nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 560 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 5,150 1,080 2,951 560 1PH8 main motors 774 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 548 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8286-F4, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 1,500 382 2,432 Irated nmax1 nmax2 nmax3 nmax, Br [A] [kW] [rpm] [rpm] [rpm] 730 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,000 4,500 1,360 2,432 730 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 775 Technical data and characteristics 6.1 Induction motors Table 6- 549 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8286-F4, (IP23) nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 445 2,429 730 3,300 - - 2,300 2,200 4,500 1,500 382 2,432 730 Imax [A] M0 [Nm] I0 [A] 1,360 2,429 730 3,300 1PH8 main motors 776 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 550 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8286-F4, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 2,000 500 2,387 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 720 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 4,500 1,360 2,387 720 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 777 Technical data and characteristics 6.1 Induction motors Table 6- 551 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8286-F4, (IP23) nN PN MN [rpm] [kW] [Nm] 2,200 475 2,062 IN nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 620 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,400 4,500 1,360 2,432 620 1PH8 main motors 778 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 552 SINAMICS, 3-ph. 690 VAC, Basic Line Module, (BLM), 1PH8286-K4, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 700 210 2,865 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 235 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,300 5,100 410 2,865 235 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 779 Technical data and characteristics 6.1 Induction motors Table 6- 553 SINAMICS, 3-ph. 690 VAC, Active Line Module, (ALM), 1PH8286-K4, (IP23) nrated Prated Mrated Irated nmax1 nmax2 nmax3 [rpm] [kW] [Nm] 800 240 2,865 700 210 2,865 235 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 235 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,600 5,100 410 2,865 235 2,000 1PH8 main motors 780 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 554 SINAMICS, 3-ph. 690 VAC, Basic Line Module, (BLM), 1PH8286-U4, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 1,000 299 2,855 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 355 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,000 5,000 610 2,855 355 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 781 Technical data and characteristics 6.1 Induction motors Table 6- 555 SINAMICS, 3-ph. 690 VAC, Active Line Module, (ALM), 1PH8286-U4, (IP23) nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,150 344 2,860 355 3,300 - - 2,300 2,200 5,000 1,000 299 2,855 355 Imax [A] M0 [Nm] I0 [A] 610 2,860 355 2,700 1PH8 main motors 782 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 556 SINAMICS, 3-ph. 690 VAC, Basic Line Module, (BLM), 1PH8286-W4, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 1,500 370 2,356 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 410 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,000 4,350 760 2,356 410 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 783 Technical data and characteristics 6.1 Induction motors Table 6- 557 SINAMICS, 3-ph. 690 VAC, Active Line Module, (ALM), 1PH8286-W4, (IP23) nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 432 2,356 410 3,300 - - 2,300 2,200 4,350 1,500 370 2,356 410 Imax [A] M0 [Nm] I0 [A] 760 2,356 410 2,600 1PH8 main motors 784 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 558 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8288-C4, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 700 272 3,711 Irated nmax1 nmax2 nmax3 nmax, Br [A] [kW] [rpm] [rpm] [rpm] 570 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,400 6,450 970 3,711 570 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 785 Technical data and characteristics 6.1 Induction motors Table 6- 559 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8288-C4, (IP23) nrated Prated Mrated Irated nmax1 nmax2 nmax3 [rpm] [kW] [Nm] 800 310 3,701 700 271 3,701 560 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 560 3,300 - - 2,300 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,550 6,450 970 3,701 560 2,800 1PH8 main motors 786 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 560 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8288-C4, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 1,000 385 3,677 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 560 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,050 6,450 970 3,677 560 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 787 Technical data and characteristics 6.1 Induction motors Table 6- 561 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8288-C4, (IP23) nN PN MN [rpm] [kW] [Nm] 1,100 405 3,516 IN nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 540 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,050 6,450 970 3,711 540 1PH8 main motors 788 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 562 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8288-D4, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 1,000 379 3,619 Irated nmax1 nmax2 nmax3 nmax, Br [A] [kW] [rpm] [rpm] [rpm] 760 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,100 6,350 1,300 3,619 760 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 789 Technical data and characteristics 6.1 Induction motors Table 6- 563 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8288-D4, (IP23) nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,150 435 3,607 760 3,300 - - 2,300 2,200 6,350 1,000 378 3,607 760 Imax [A] M0 [Nm] I0 [A] 1,300 3,607 760 3,300 1PH8 main motors 790 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 564 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8288-D4, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 1,350 505 3,573 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 750 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 6,350 1,300 3,573 750 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 791 Technical data and characteristics 6.1 Induction motors Table 6- 565 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8288-D4, (IP23) nN PN MN [rpm] [kW] [Nm] 1,500 505 3,215 IN nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 680 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 6,350 1,300 3,619 680 1PH8 main motors 792 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 566 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8288-F4, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 1,500 480 3,056 Irated nmax1 nmax2 nmax3 nmax, Br [A] [kW] [rpm] [rpm] [rpm] 910 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,100 5,500 1,640 3,056 910 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 793 Technical data and characteristics 6.1 Induction motors Table 6- 567 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8288-F4, (IP23) nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 560 3,055 910 3,300 - - 2,300 2,200 5,500 1,500 480 3,055 910 Imax [A] M0 [Nm] I0 [A] 1,640 3,055 910 3,300 1PH8 main motors 794 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 568 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8288-F4, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 2,000 630 3,009 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 900 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 5,500 1,640 3,009 900 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 795 Technical data and characteristics 6.1 Induction motors Table 6- 569 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8288-F4, (IP23) nN PN MN [rpm] [kW] [Nm] 2,200 599 2,600 IN nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 790 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,400 5,500 1,640 3,056 790 1PH8 main motors 796 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 570 SINAMICS, 3-ph. 690 VAC, Basic Line Module, (BLM), 1PH8288-K4, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 700 263 3,588 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 295 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,400 6,300 520 3,588 295 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 797 Technical data and characteristics 6.1 Induction motors Table 6- 571 SINAMICS, 3-ph. 690 VAC, Active Line Module, (ALM), 1PH8288-K4, (IP23) nrated Prated Mrated Irated nmax1 nmax2 nmax3 [rpm] [kW] [Nm] 800 300 3,581 700 263 3,581 290 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 290 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,600 6,300 520 3,581 290 1,900 1PH8 main motors 798 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 572 SINAMICS, 3-ph. 690 VAC, Basic Line Module, (BLM), 1PH8288-U4, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 1,000 367 3,505 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 425 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,100 6,250 740 3,505 425 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 799 Technical data and characteristics 6.1 Induction motors Table 6- 573 SINAMICS, 3-ph. 690 VAC, Active Line Module, (ALM), 1PH8288-U4, (IP23) nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,150 422 3,504 425 3,300 - - 2,300 2,200 6,250 1,000 367 3,504 425 Imax [A] M0 [Nm] I0 [A] 740 3,504 425 2,600 1PH8 main motors 800 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 574 SINAMICS, 3-ph. 690 VAC, Basic Line Module, (BLM), 1PH8288-W4, (IP23) nrated Prated Mrated [rpm] [kW] [Nm] 1,500 465 2,961 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 520 3,300 - - 2,300 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,100 5,350 920 2,961 520 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 801 Technical data and characteristics 6.1 Induction motors Table 6- 575 SINAMICS, 3-ph. 690 VAC, Active Line Module, (ALM), 1PH8288-W4, (IP23) nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 543 2,964 510 3,300 - - 2,300 2,200 5,350 1,500 466 2,964 510 Imax [A] M0 [Nm] I0 [A] 920 2,964 510 2,600 1PH8 main motors 802 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors 6.1.3 Characteristics water cooling 6.1.3.1 Shaft height 80 - water-cooled Table 6- 576 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8083-F2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,500 3.5 22 8.9 10,000 12,000 - 5,000 3,550 32 13 23 9 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 803 Technical data and characteristics 6.1 Induction motors Table 6- 577 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8083-F2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 4 22 8.7 10,000 12,000 - 5,000 4,100 32 1,500 3.5 22 8.9 Imax [A] M0 [Nm] I0 [A] 13 23 9 4,850 1PH8 main motors 804 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 578 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8083-F2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 2,000 4.6 22 8.7 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 10,000 12,000 - 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,250 32 13 23 9 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 805 Technical data and characteristics 6.1 Induction motors Table 6- 579 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8083-F2 nN PN MN IN [rpm] [kW] [Nm] [A] 2,200 5 22 8.7 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 10,000 12,000 -- 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 5,050 32 13 23 9 1PH8 main motors 806 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 580 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8083-G2, nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,000 4.3 21 12 10,000 15,000 16,000 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 7,200 45 26 23 13 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 807 Technical data and characteristics 6.1 Induction motors Table 6- 581 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8083-G2, nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 2,300 4.9 20 12 10,000 15,000 16,000 5,000 8,150 45 2,000 4.3 21 12 Imax [A] M0 [Nm] I0 [A] 26 23 13 9,150 1PH8 main motors 808 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 582 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8083-G2, nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,650 5.6 20 12 10,000 15,000 16,000 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 8,500 45 26 23 13 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 809 Technical data and characteristics 6.1 Induction motors Table 6- 583 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8083-G2, nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,800 6 20 12 10,000 15,000 16,000 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 8,900 45 26 23 13 1PH8 main motors 810 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 584 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8083-N2, nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 4,500 6.7 14 18 10,000 15,000 20,000 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 15,850 45 45 23 23 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 811 Technical data and characteristics 6.1 Induction motors Table 6- 585 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8083-N2, nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 5,000 7.5 14 18 10,000 15,000 20,000 5,000 17,700 45 4,500 6.7 14 18 Imax [A] M0 [Nm] I0 [A] 45 23 23 18,950 1PH8 main motors 812 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 586 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Line Module, (SLM/BLM), 1PH8083-N2, nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 5,500 8.2 14 18 10,000 15,000 20,000 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 19,500 45 45 23 23 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 813 Technical data and characteristics 6.1 Induction motors Table 6- 587 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8083-N2, nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 6,000 8.9 14 18 10,000 15,000 20,000 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 19,450 45 45 23 23 1PH8 main motors 814 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 588 SINAMICS, 3-ph. 400 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8087-F2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 1,500 4.6 29 13.7 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 10,000 15,000 - 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 6,000 65 29 34 15 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 815 Technical data and characteristics 6.1 Induction motors Table 6- 589 SINAMICS, 3-ph. 400 V AC, Active Line Module, (ALM), 1PH8087-F2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 5.4 29 13.7 10,000 15,000 - 5,000 6,600 65 1,500 4.6 29 13.7 Imax [A] M0 [Nm] I0 [A] 29 34 15 7,700 1PH8 main motors 816 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 590 SINAMICS, 3-ph. 480 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8087-F2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 2,000 6.1 29 13.7 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 10,000 15,000 - 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 6,950 65 29 34 15 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 817 Technical data and characteristics 6.1 Induction motors Table 6- 591 SINAMICS, 3-ph. 480 V AC, Active Line Module, (ALM), 1PH8087-F2 nN PN MN IN [rpm] [kW] [Nm] [A] 2,200 6.7 29 13.7 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 10,000 15,000 -- 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 7,100 65 29 34 15 1PH8 main motors 818 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 592 SINAMICS, 3-ph. 400 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8087-G2, nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,000 6.1 29 17.5 10,000 15,000 19,000 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 7,950 65 38 34 19 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 819 Technical data and characteristics 6.1 Induction motors Table 6- 593 SINAMICS, 3-ph. 400 V AC, Active Line Module, (ALM), 1PH8087-G2, nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 2,300 7 29 17.7 10,000 15,000 19,000 5,000 8,850 65 2,000 6.1 29 17.5 Imax [A] M0 [Nm] I0 [A] 38 34 19 10,000 1PH8 main motors 820 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 594 SINAMICS, 3-ph. 480 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8087-G2, nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,650 8.1 29 17.8 10,000 15,000 19,000 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 9,150 65 38 34 19 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 821 Technical data and characteristics 6.1 Induction motors Table 6- 595 SINAMICS, 3-ph. 480 V AC, Active Line Module, (ALM), 1PH8087-G2 nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,800 8.5 29 17.8 10,000 15,000 19,000 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 9,700 65 38 34 19 1PH8 main motors 822 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 596 SINAMICS, 3-ph. 400 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8087-N2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 4,500 8.5 18 24 10,000 15,000 20,000 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 16,750 65 69 27 31 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 823 Technical data and characteristics 6.1 Induction motors Table 6- 597 SINAMICS, 3-ph. 400 V AC, Active Line Module, (ALM), 1PH8087-N2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 5,000 9.5 18 24 10,000 15,000 20,000 5,000 18,700 65 4,500 8.5 18 24 Imax [A] M0 [Nm] I0 [A] 69 27 31 20,000 1PH8 main motors 824 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 598 SINAMICS, 3-ph. 480 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8087-N2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 5,500 10.5 18 24 10,000 15,000 20,000 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 19,900 65 69 27 31 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 825 Technical data and characteristics 6.1 Induction motors Table 6- 599 SINAMICS, 3-ph. 480 V AC, Active Line Module, (ALM), 1PH8087-N2 nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 6,000 11.4 18 24 10,000 15,000 20,000 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 20,000 65 69 27 31 1PH8 main motors 826 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors 6.1.3.2 Shaft height 80 - Water cooling - Premium Performance Note Symbols of the characteristic curves for 1PH808 Premium Performance You will find the explanation of the symbols for these motors in Chapter "Configuration for 1PH808 Premium Performance." See also Configuration for 1PH808 Premium Performance (Page 223) 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 827 Technical data and characteristics 6.1 Induction motors Table 6- 600 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8081-U nN PN MN IN [rpm] [kW] [Nm] [A] 9,000 7.5 8 25 n2 nmax Imax1 Imax2 Imax3 Mmax1 Mmax2 Mmax3 fcycle [rpm] [rpm] [A] [A] [A] [Nm] [Nm] [Nm] [kHz] 24,000 24,000 77 -- -- 27 -- -- 4 1PH8 main motors 828 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 601 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8081-U nN PN MN IN [rpm] [kW] [Nm] [A] 9,000 7.5 8 25 n2 nmax Imax1 Imax2 Imax3 Mmax1 Mmax2 Mmax3 fcycle [rpm] [rpm] [A] [A] [A] [Nm] [Nm] [Nm] [kHz] 15,000 24,000 77 -- -- 27 -- -- 4 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 829 Technical data and characteristics 6.1 Induction motors Table 6- 602 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8081-U nN PN MN IN [rpm] [kW] [Nm] [A] 10,000 8.4 8 25 n2 nmax Imax1 Imax2 Imax3 Mmax1 Mmax2 Mmax3 fcycle [rpm] [rpm] [A] [A] [A] [Nm] [Nm] [Nm] [kHz] 24,000 24,000 77 -- -- 27 -- -- 4 1PH8 main motors 830 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 603 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8081-U nN PN MN IN [rpm] [kW] [Nm] [A] 10,000 8.4 8 25 n2 nmax Imax1 Imax2 Imax3 Mmax1 Mmax2 Mmax3 fcycle [rpm] [rpm] [A] [A] [A] [Nm] [Nm] [Nm] [kHz] 16,000 24,000 77 -- -- 27 -- -- 4 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 831 Technical data and characteristics 6.1 Induction motors Table 6- 604 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8081-T nN PN MN IN [rpm] [kW] [Nm] [A] 9,000 8 8.5 25.6 n2 nmax Imax1 Imax2 Imax3 Mmax1 Mmax2 Mmax3 fcycle [rpm] [rpm] [A] [A] [A] [Nm] [Nm] [Nm] [kHz] 24,000 24,000 77 -- -- 32 -- -- 4 1PH8 main motors 832 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 605 SINAMICS, 3-ph. 400 V AC, Active Line Module, (ALM), 1PH8081-T nN PN MN IN [rpm] [kW] [Nm] [A] 9,000 8 8.5 25.6 n2 nmax Imax1 Imax2 Imax3 Mmax1 Mmax2 Mmax3 fcycle [rpm] [rpm] [A] [A] [A] [Nm] [Nm] [Nm] [kHz] 24,000 24,000 77 -- -- 32 -- -- 4 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 833 Technical data and characteristics 6.1 Induction motors Table 6- 606 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8081-T nN PN MN IN [rpm] [kW] [Nm] [A] 10,000 8.9 8.5 25.6 n2 nmax Imax1 Imax2 Imax3 Mmax1 Mmax2 Mmax3 fcycle [rpm] [rpm] [A] [A] [A] [Nm] [Nm] [Nm] [kHz] 18,000 24,000 77 -- -- 32 -- -- 4 1PH8 main motors 834 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 607 SINAMICS, 3-ph. 480 V AC, Active Line Module, (ALM), 1PH8081-T nN PN MN IN [rpm] [kW] [Nm] [A] 10,000 8.9 8.5 25.6 n2 nmax Imax1 Imax2 Imax3 Mmax1 Mmax2 Mmax3 fcycle [rpm] [rpm] [A] [A] [A] [Nm] [Nm] [Nm] [kHz] 18,000 24,000 77 -- -- 32 -- -- 4 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 835 Technical data and characteristics 6.1 Induction motors Table 6- 608 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8081-V nN PN MN IN [rpm] [kW] [Nm] [A] 9,000 7.7 8.2 23.8 n2 nmax Imax1 Imax2 Imax3 Mmax1 Mmax2 Mmax3 fcycle [rpm] [rpm] [A] [A] [A] [Nm] [Nm] [Nm] [kHz] 24,000 24,000 54 -- -- 21 -- -- 8 1PH8 main motors 836 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 609 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8081-V nN PN MN IN [rpm] [kW] [Nm] [A] 9,000 7.7 8.2 23.8 n2 nmax Imax1 Imax2 Imax3 Mmax1 Mmax2 Mmax3 fcycle [rpm] [rpm] [A] [A] [A] [Nm] [Nm] [Nm] [kHz] 18,000 24,000 54 -- -- 21 -- -- 8 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 837 Technical data and characteristics 6.1 Induction motors Table 6- 610 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8081-V nN PN MN IN [rpm] [kW] [Nm] [A] 10,000 8.6 8.2 23.8 n2 nmax Imax1 Imax2 Imax3 Mmax1 Mmax2 Mmax3 fcycle [rpm] [rpm] [A] [A] [A] [Nm] [Nm] [Nm] [kHz] 24,000 24,000 54 -- -- 21 -- -- 8 1PH8 main motors 838 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 611 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8081-V nN PN MN IN [rpm] [kW] [Nm] [A] 10,000 8.6 8.2 23.8 n2 nmax Imax1 Imax2 Imax3 Mmax1 Mmax2 Mmax3 fcycle [rpm] [rpm] [A] [A] [A] [Nm] [Nm] [Nm] [kHz] 16,000 24,000 54 -- -- 21 -- -- 8 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 839 Technical data and characteristics 6.1 Induction motors Table 6- 612 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8081-W nN PN MN IN [rpm] [kW] [Nm] [A] 9,000 7.3 7.7 23.9 n2 nmax Imax1 Imax2 Imax3 Mmax1 Mmax2 Mmax3 fcycle [rpm] [rpm] [A] [A] [A] [Nm] [Nm] [Nm] [kHz] 24,000 24,000 54 -- -- 18 -- -- 8 1PH8 main motors 840 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 613 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8081-W nN PN MN IN [rpm] [kW] [Nm] [A] 9,000 7.3 7.7 23.9 n2 nmax Imax1 Imax2 Imax3 Mmax1 Mmax2 Mmax3 fcycle [rpm] [rpm] [A] [A] [A] [Nm] [Nm] [Nm] [kHz] 24,000 24,000 54 -- -- 18 -- -- 8 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 841 Technical data and characteristics 6.1 Induction motors Table 6- 614 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8081-W nN PN MN IN [rpm] [kW] [Nm] [A] 10,000 8.1 7.7 23.9 n2 nmax Imax1 Imax2 Imax3 Mmax1 Mmax2 Mmax3 fcycle [rpm] [rpm] [A] [A] [A] [Nm] [Nm] [Nm] [kHz] 24,000 24,000 54 -- -- 18 -- -- 8 1PH8 main motors 842 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 615 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8081-W nN PN MN IN [rpm] [kW] [Nm] [A] 10,000 8.1 7.7 23.9 n2 nmax Imax1 Imax2 Imax3 Mmax1 Mmax2 Mmax3 fcycle [rpm] [rpm] [A] [A] [A] [Nm] [Nm] [Nm] [kHz] 16,000 24,000 54 -- -- 18 -- -- 8 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 843 Technical data and characteristics 6.1 Induction motors Table 6- 616 SINAMICS, 3-ph. 400 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8083-T nN PN MN IN [rpm] [kW] [Nm] [A] 12,000 9 7.2 24 n2 nmax Imax1 Imax2 Imax3 Mmax1 Mmax2 Mmax3 fcycle [rpm] [rpm] [A] [A] [A] [Nm] [Nm] [Nm] [kHz] 24,000 24,000 78 -- -- 24 -- -- 4 1PH8 main motors 844 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 617 SINAMICS, 3-ph. 400 V AC, Active Line Module, (ALM), 1PH8083-T nN PN MN IN [rpm] [kW] [Nm] [A] 12,000 9 7.2 24 n2 nmax Imax1 Imax2 Imax3 Mmax1 Mmax2 Mmax3 fcycle [rpm] [rpm] [A] [A] [A] [Nm] [Nm] [Nm] [kHz] 24,000 24,000 78 -- -- 24 -- -- 4 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 845 Technical data and characteristics 6.1 Induction motors Table 6- 618 SINAMICS, 3-ph. 480 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8083-T nN PN MN IN [rpm] [kW] [Nm] [A] 13,000 9.8 7.2 24 n2 nmax Imax1 Imax2 Imax3 Mmax1 Mmax2 Mmax3 fcycle [rpm] [rpm] [A] [A] [A] [Nm] [Nm] [Nm] [kHz] 24,000 24,000 78 -- -- 24 -- -- 4 1PH8 main motors 846 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 619 SINAMICS, 3-ph. 480 V AC, Active Line Module, (ALM), 1PH8083-T nN PN MN IN [rpm] [kW] [Nm] [A] 13,000 9.8 7.2 24 n2 nmax Imax1 Imax2 Imax3 Mmax1 Mmax2 Mmax3 fcycle [rpm] [rpm] [A] [A] [A] [Nm] [Nm] [Nm] [kHz] 24,000 24,000 78 -- -- 24 -- -- 4 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 847 Technical data and characteristics 6.1 Induction motors Table 6- 620 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8083-U nN PN MN IN [rpm] [kW] [Nm] [A] 5,200 10 18.4 26.4 n2 nmax Imax1 Imax2 Imax3 Mmax1 Mmax2 Mmax3 fcycle [rpm] [rpm] [A] [A] [A] [Nm] [Nm] [Nm] [kHz] 10,000 24,000 81 -- -- 64 -- -- 4 1PH8 main motors 848 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 621 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8083-U nN PN MN IN [rpm] [kW] [Nm] [A] 5,200 10 18.4 26.4 n2 nmax Imax1 Imax2 Imax3 Mmax1 Mmax2 Mmax3 fcycle [rpm] [rpm] [A] [A] [A] [Nm] [Nm] [Nm] [kHz] 12,000 24,000 81 -- -- 64 -- -- 4 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 849 Technical data and characteristics 6.1 Induction motors Table 6- 622 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8083-U nN PN MN IN [rpm] [kW] [Nm] [A] 5,600 10.7 18.2 26.4 n2 nmax Imax1 Imax2 Imax3 Mmax1 Mmax2 Mmax3 fcycle [rpm] [rpm] [A] [A] [A] [Nm] [Nm] [Nm] [kHz] 12,000 24,000 81 -- -- 64 -- -- 4 1PH8 main motors 850 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 623 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8083-U nN PN MN IN [rpm] [kW] [Nm] [A] 5,600 10.7 18.2 26.4 n2 nmax Imax1 Imax2 Imax3 Mmax1 Mmax2 Mmax3 fcycle [rpm] [rpm] [A] [A] [A] [Nm] [Nm] [Nm] [kHz] 12,000 24,000 81 -- -- 64 -- -- 4 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 851 Technical data and characteristics 6.1 Induction motors Table 6- 624 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8087-U nN PN MN IN [rpm] [kW] [Nm] [A] 5,000 11 21 25.1 n2 nmax Imax1 Imax2 Imax3 Mmax1 Mmax2 Mmax3 fcycle [rpm] [rpm] [A] [A] [A] [Nm] [Nm] [Nm] [kHz] 10,000 24,000 56 -- -- 54 -- -- 4 1PH8 main motors 852 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 625 SINAMICS, 3-ph. 400 V AC, Active Line Module, (ALM), 1PH8087-U nN PN MN IN [rpm] [kW] [Nm] [A] 5,000 11 21 25.1 n2 nmax Imax1 Imax2 Imax3 Mmax1 Mmax2 Mmax3 fcycle [rpm] [rpm] [A] [A] [A] [Nm] [Nm] [Nm] [kHz] 12,000 24,000 71 -- -- 67 -- -- 4 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 853 Technical data and characteristics 6.1 Induction motors Table 6- 626 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8087-U nN PN MN IN [rpm] [kW] [Nm] [A] 5,500 12.1 21 25.1 n2 nmax Imax1 Imax2 Imax3 Mmax1 Mmax2 Mmax3 fcycle [rpm] [rpm] [A] [A] [A] [Nm] [Nm] [Nm] [kHz] 13,000 24,000 71 -- -- 67 -- -- 4 1PH8 main motors 854 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 627 SINAMICS, 3-ph. 480 V AC, Active Line Module, (ALM), 1PH8087-U nN PN MN IN [rpm] [kW] [Nm] [A] 5,500 12.1 21 25.1 n2 nmax Imax1 Imax2 Imax3 Mmax1 Mmax2 Mmax3 fcycle [rpm] [rpm] [A] [A] [A] [Nm] [Nm] [Nm] [kHz] 15,000 24,000 71 -- -- 67 -- -- 4 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 855 Technical data and characteristics 6.1 Induction motors 6.1.3.3 Shaft height 100 - water-cooled Table 6- 628 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8101-F2 nrated Prated Mrated [rpm] [kW] [Nm] 1,500 5 32 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 12.8 9,000 - - 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,500 50 25 34 13 1PH8 main motors 856 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 629 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8101-F2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 5.8 32 12.8 9,000 - - 5,000 2,500 50 1,500 5 32 12.8 Imax [A] M0 [Nm] I0 [A] 25 34 13 4,200 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 857 Technical data and characteristics 6.1 Induction motors Table 6- 630 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8101-F2 nrated Prated Mrated [rpm] [kW] [Nm] 2,000 6.6 32 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 12.5 9,000 - - 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,500 50 25 34 13 1PH8 main motors 858 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 631 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8101-F2 nN PN MN [rpm] [kW] [Nm] 2,200 7.2 31 IN nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 12.5 9,000 - - 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,000 50 25 34 13 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 859 Technical data and characteristics 6.1 Induction motors Table 6- 632 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8101-G2, nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 2,000 6.4 31 16.8 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 9,000 12,000 - 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,000 60 33 34 18 1PH8 main motors 860 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 633 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8101-G2, nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 2,300 7.3 30 16.8 9,000 12,000 - 5,000 5,000 60 2,000 6.4 31 16.8 6,800 1,500 5 32 17.3 9,600 Imax [A] M0 [Nm] I0 [A] 33 34 18 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 861 Technical data and characteristics 6.1 Induction motors Table 6- 634 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8101-G2, nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 2,650 8.4 30 16.8 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 9,000 12,000 - 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,000 60 33 34 18 1PH8 main motors 862 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 635 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8101-G2, nN PN MN IN [rpm] [kW] [Nm] [A] 2,800 8.3 28 16.5 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 9,000 12,000 - 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 5,000 60 33 34 18 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 863 Technical data and characteristics 6.1 Induction motors Table 6- 636 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8103-F2 nrated Prated Mrated [rpm] [kW] [Nm] 1,500 7.1 45 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 19.7 9,000 - - 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,000 85 33 48 20 1PH8 main motors 864 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 637 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8103-F2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 8.2 45 19.7 9,000 - - 5,000 5,000 85 1,500 7.1 45 19.7 Imax [A] M0 [Nm] I0 [A] 33 48 20 6,400 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 865 Technical data and characteristics 6.1 Induction motors Table 6- 638 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8103-F2 nrated Prated Mrated [rpm] [kW] [Nm] 2,000 9.4 45 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 19.7 9,000 - - 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 5,000 85 33 48 20 1PH8 main motors 866 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 639 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8103-F2 nN PN MN [rpm] [kW] [Nm] 2,200 10.3 45 IN nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 19.7 9,000 -- -- 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 5,000 85 37 48 20 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 867 Technical data and characteristics 6.1 Induction motors Table 6- 640 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8103-G2, nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 2,000 9.5 45 23.8 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 9,000 12,000 - 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,000 85 46 48 24 1PH8 main motors 868 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 641 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8103-G2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 2,300 10.9 45 23.8 9,000 12,000 - 5,000 3,000 85 2,000 9.5 45 23.8 5,300 1,500 7 45 23.7 8,900 Imax [A] M0 [Nm] I0 [A] 46 48 24 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 869 Technical data and characteristics 6.1 Induction motors Table 6- 642 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8103-G2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 2,650 12.5 45 23.5 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 9,000 12,000 - 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,000 85 46 48 24 1PH8 main motors 870 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 643 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8103-G2 nN PN MN IN [rpm] [kW] [Nm] [A] 2,800 12.8 44 22.5 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 9,000 12,000 - 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,500 85 46 48 24 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 871 Technical data and characteristics 6.1 Induction motors Table 6- 644 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8103-M2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 3,000 10.6 34 30 9,000 12,000 18,000 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 11,900 95 82 46 35 1PH8 main motors 872 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 645 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8103-M2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 3,300 11.7 34 30 9,000 12,000 18,000 5,000 13,550 95 3,000 10.6 34 30 Imax [A] M0 [Nm] I0 [A] 82 46 35 14,600 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 873 Technical data and characteristics 6.1 Induction motors Table 6- 646 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8103-M2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 3,600 12.7 34 29.7 9,000 12,000 18,000 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 14,650 95 82 46 35 1PH8 main motors 874 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 647 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8103-M2 nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 3,900 13 32 29 9,000 12,000 18,000 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 13,000 95 82 46 35 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 875 Technical data and characteristics 6.1 Induction motors Table 6- 648 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8105-F2 nrated Prated Mrated [rpm] [kW] [Nm] 1,500 11.0 70 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 28.5 9,000 - - 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,500 130 54 74 29 1PH8 main motors 876 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 649 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8105-F2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 12.5 68 28.5 9,000 - - 5,000 3,400 130 1,500 11.0 70 28.5 Imax [A] M0 [Nm] I0 [A] 54 74 29 5,000 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 877 Technical data and characteristics 6.1 Induction motors Table 6- 650 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8105-F2 nrated Prated Mrated [rpm] [kW] [Nm] 2,000 14 67 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 27.5 9,000 - - 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,000 130 54 74 29 1PH8 main motors 878 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 651 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8105-F2 nN PN MN [rpm] [kW] [Nm] 2,200 15.4 67 IN nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 27.5 9,000 -- -- 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,500 130 54 74 29 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 879 Technical data and characteristics 6.1 Induction motors Table 6- 652 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8105-G2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 2,000 13.0 62 34.5 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 9,000 12,000 - 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,000 140 75 74 38 1PH8 main motors 880 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 653 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8105-G2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 2,300 15 62 34 9,000 12,000 - 5,000 3,500 140 2,000 13 62 34.5 6,750 1,500 11 70 35.2 10,000 Imax [A] M0 [Nm] I0 [A] 75 74 38 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 881 Technical data and characteristics 6.1 Induction motors Table 6- 654 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8105-G2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 2,650 17 61 33.5 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 9,000 12,000 - 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,500 140 75 74 38 1PH8 main motors 882 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 655 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8105-G2 nN PN MN IN [rpm] [kW] [Nm] [A] 2,800 18 61 33.5 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 9,000 12,000 -- 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,500 140 75 74 38 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 883 Technical data and characteristics 6.1 Induction motors Table 6- 656 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8105-M2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 3,000 16.8 53 45 9,000 12,000 18,000 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 8,050 145 119 71 52 1PH8 main motors 884 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 657 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8105-M2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 3,300 18.5 54 45 9,000 12,000 18,000 5,000 9,050 145 3,000 16.8 53 45 Imax [A] M0 [Nm] I0 [A] 119 71 52 11,700 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 885 Technical data and characteristics 6.1 Induction motors Table 6- 658 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8105-M2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 3,600 20 53 45 9,000 12,000 18,000 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 10,000 145 119 71 42 1PH8 main motors 886 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 659 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8105-M2 nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 3,900 21 51 43.5 9,000 12,000 18,000 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 10,000 145 119 71 52 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 887 Technical data and characteristics 6.1 Induction motors Table 6- 660 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8107-F2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 1,500 14 89 43.7 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 9,000 12,000 - 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 5,600 180 89 94 44 1PH8 main motors 888 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 661 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8107-F2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 15.5 85 42 9,000 12,000 - 5,000 4,500 180 1,500 14 89 43.7 Imax [A] M0 [Nm] I0 [A] 89 94 44 6,400 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 889 Technical data and characteristics 6.1 Induction motors Table 6- 662 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8107-F2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 2,000 18 86 42.6 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 9,000 12,000 - 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,000 180 89 94 44 1PH8 main motors 890 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 663 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8107-F2 nN PN MN IN [rpm] [kW] [Nm] [A] 2,200 19.8 86 42.6 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 9,000 12,000 -- 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,500 180 89 94 44 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 891 Technical data and characteristics 6.1 Induction motors Table 6- 664 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8107-M2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 3,000 18 57 60 9,000 12,000 18,000 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 17,000 180 183 82 73 1PH8 main motors 892 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 665 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8107-M2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 3,300 20 58 60 9,000 12,000 18,000 5,000 18,050 180 3,000 18 57 60 Imax [A] M0 [Nm] I0 [A] 183 82 73 18,050 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 893 Technical data and characteristics 6.1 Induction motors Table 6- 666 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8107-M2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 3,600 21 56 59 9,000 12,000 18,000 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 17,650 180 183 82 73 1PH8 main motors 894 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 667 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8107-M2 nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 3,900 21.6 53 58 9,000 12,000 18,000 5,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 18,000 180 183 82 73 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 895 Technical data and characteristics 6.1 Induction motors 6.1.3.4 Shaft height 132 - water-cooled Table 6- 668 SINAMICS, 3-ph. 400 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8131-F2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 1,500 15 96 30 8,000 10,000 11,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,500 145 46 101 31 1PH8 main motors 896 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 669 SINAMICS, 3-ph. 400 V AC, Active Line Module, (ALM), 1PH8131-F2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 17 93 30 8,000 10,000 11,000 4,500 2,500 145 1,500 15 96 30 Imax [A] M0 [Nm] I0 [A] 46 101 31 3,200 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 897 Technical data and characteristics 6.1 Induction motors Table 6- 670 SINAMICS, 3-ph. 480 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8131-F2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,000 18.5 88 30 8,000 10,000 11,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,500 145 46 101 31 1PH8 main motors 898 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 671 SINAMICS, 3-ph. 480 V AC, Active Line Module, (ALM), 1PH8131-F2 nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,200 20 87 29 8,000 10,000 11,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,000 145 46 101 31 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 899 Technical data and characteristics 6.1 Induction motors Table 6- 672 SINAMICS, 3-ph. 400 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8131-G2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,000 18 86 40 8,000 10,000 14,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,000 200 93 101 44 1PH8 main motors 900 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 673 SINAMICS, 3-ph. 400 V AC, Active Line Module, (ALM), 1PH8131-G2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 2,300 20 83 39 8,000 10,000 14,000 4,500 4,000 200 2,000 18 86 40 5,500 1,500 14.3 91 41 7,800 Imax [A] M0 [Nm] I0 [A] 93 101 44 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 901 Technical data and characteristics 6.1 Induction motors Table 6- 674 SINAMICS, 3-ph. 480 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8131-G2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,650 23 83 39 8,000 10,000 14,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,500 200 93 101 44 1PH8 main motors 902 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 675 SINAMICS, 3-ph. 480 V AC, Active Line Module, (ALM), 1PH8131-G2 nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,800 24 82 39 8,000 10,000 14,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 6,000 200 93 101 44 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 903 Technical data and characteristics 6.1 Induction motors Table 6- 676 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8133-F2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 1,500 17 108 38 8,000 10,000 13,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,500 240 85 136 45 1PH8 main motors 904 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 677 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8133-F2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 19.5 106 38 8,000 10,000 13,000 4,500 3,500 240 1,500 17 108 38 Imax [A] M0 [Nm] I0 [A] 85 136 45 4,500 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 905 Technical data and characteristics 6.1 Induction motors Table 6- 678 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8133-F2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,000 22.5 107 38 8,000 10,000 13,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,000 240 85 136 45 1PH8 main motors 906 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 679 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8133-F2 nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,200 24 104 37 8,000 10,000 13,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,500 240 85 136 45 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 907 Technical data and characteristics 6.1 Induction motors Table 6- 680 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8133-G2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,000 22 105 52 8,000 10,000 15,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 5,000 260 129 134 61 1PH8 main motors 908 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 681 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8133-G2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 2,300 25 104 52 8,000 10,000 15,000 4,500 6,000 260 2,000 22 105 52 7,000 1,500 18.4 117 54 8,000 Imax [A] M0 [Nm] I0 [A] 129 134 61 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 909 Technical data and characteristics 6.1 Induction motors Table 6- 682 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8133-G2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,650 28 101 50 8,000 10,000 15,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 6,000 260 129 134 61 1PH8 main motors 910 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 683 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8133-G2 nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,800 29 99 50 8,000 10,000 15,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 6,000 260 129 134 61 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 911 Technical data and characteristics 6.1 Induction motors Table 6- 684 SINAMICS, 3-ph. 400 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8135-F2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 1,500 22 140 51 8,000 10,000 14,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,000 320 117 172 58 1PH8 main motors 912 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 685 SINAMICS, 3-ph. 400 V AC, Active Line Module, (ALM), 1PH8135-F2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 25.5 139 51 8,000 10,000 14,000 4,500 4,000 320 1,500 22 140 51 Imax [A] M0 [Nm] I0 [A] 117 172 58 5,250 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 913 Technical data and characteristics 6.1 Induction motors Table 6- 686 SINAMICS, 3-ph. 480 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8135-F2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,000 29 138 52 8,000 10,000 14,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,500 320 117 172 58 1PH8 main motors 914 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 687 SINAMICS, 3-ph. 480 V AC, Active Line Module, (ALM), 1PH8135-F2 nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,200 31 135 50 8,000 10,000 14,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,500 320 117 172 58 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 915 Technical data and characteristics 6.1 Induction motors Table 6- 688 SINAMICS, 3-ph. 400 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8135-G2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,000 29 138 64 8,000 10,000 15,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,500 320 148 170 73 1PH8 main motors 916 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 689 SINAMICS, 3-ph. 400 V AC, Active Line Module, (ALM), 1PH8135-G2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 2,300 31 129 61 8,000 10,000 15,000 4,500 4,500 320 2,000 29 138 64 5,250 1,500 23.1 147 63 7,300 Imax [A] M0 [Nm] I0 [A] 148 170 73 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 917 Technical data and characteristics 6.1 Induction motors Table 6- 690 SINAMICS, 3-ph. 480 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8135-G2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,650 32 115 58 8,000 10,000 15,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 5,500 320 148 170 73 1PH8 main motors 918 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 691 SINAMICS, 3-ph. 480 V AC, Active Line Module, (ALM), 1PH8135-G2 nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,800 33 113 57 8,000 10,000 15,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 6,000 320 148 170 73 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 919 Technical data and characteristics 6.1 Induction motors Table 6- 692 SINAMICS, 3-ph. 400 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8137-F2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 1,500 27 172 67 8,000 10,000 15,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,000 400 156 202 73 1PH8 main motors 920 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 693 SINAMICS, 3-ph. 400 V AC, Active Line Module, (ALM), 1PH8137-F2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 31.5 172 67 8,000 10,000 15,000 4,500 4,500 400 1,500 27 172 67 Imax [A] M0 [Nm] I0 [A] 156 202 73 6,500 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 921 Technical data and characteristics 6.1 Induction motors Table 6- 694 SINAMICS, 3-ph. 480 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8137-F2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,000 36 172 67 8,000 10,000 15,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,000 400 156 202 73 1PH8 main motors 922 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 695 SINAMICS, 3-ph. 480 V AC, Active Line Module, (ALM), 1PH8137-F2 nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,200 39 169 66 8,000 10,000 15,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,500 400 156 202 73 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 923 Technical data and characteristics 6.1 Induction motors Table 6- 696 SINAMICS, 3-ph. 400 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8138-F2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 1,500 30 191 80 8,000 10,000 15,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 5,000 400 168 223 88 1PH8 main motors 924 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 697 SINAMICS, 3-ph. 400 V AC, Active Line Module, (ALM), 1PH8138-F2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 33 180 77 8,000 10,000 15,000 4,500 5,000 400 1,500 30 191 80 Imax [A] M0 [Nm] I0 [A] 168 223 88 7,000 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 925 Technical data and characteristics 6.1 Induction motors Table 6- 698 SINAMICS, 3-ph. 480 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8138-F2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,000 37 177 76 8,000 10,000 15,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,000 400 168 223 88 1PH8 main motors 926 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 699 SINAMICS, 3-ph. 480 V AC, Active Line Module, (ALM), 1PH8138-F2 nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,200 39 169 72 8,000 10,000 15,000 4,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 5,000 400 168 223 88 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 927 Technical data and characteristics 6.1 Induction motors 6.1.3.5 Shaft height 160 - water cooling Table 6- 700 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8163-F2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] 1,500 37 236 84 6,500 9,000 10,000 4,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,000 600 208 288 96 1PH8 main motors 928 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 701 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8163-F2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 43 235 84 6,500 9,000 10,000 4,000 3,500 600 1,500 37 236 84 Imax [A] M0 [Nm] I0 [A] 208 288 96 5,000 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 929 Technical data and characteristics 6.1 Induction motors Table 6- 702 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8163-F2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,000 49 234 80 6,500 9,000 10,000 4,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,500 600 208 288 96 1PH8 main motors 930 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 703 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8163-F2 nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,200 53 230 83 6,500 9,000 10,000 4,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,500 600 208 288 96 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 931 Technical data and characteristics 6.1 Induction motors Table 6- 704 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8163-G2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] 2,000 42 201 93 6,500 9,000 10,000 4,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 5,000 560 253 281 120 1PH8 main motors 932 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 705 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8163-G2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 2,300 48 199 93 6,500 9,000 10,000 4,000 4,000 560 2,000 42 201 93 5,800 1,500 37 236 98 6,600 Imax [A] M0 [Nm] I0 [A] 253 281 120 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 933 Technical data and characteristics 6.1 Induction motors Table 6- 706 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8163-G2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,650 55 198 90 6,500 9,000 10,000 4,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 5,000 560 253 281 120 1PH8 main motors 934 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 707 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8163-G2 nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,800 56 191 89 6,500 9,000 10,000 4,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 5,500 560 253 281 120 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 935 Technical data and characteristics 6.1 Induction motors Table 6- 708 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8165-F2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] 1,500 46.0 293 104.0 6,500 9,000 10,000 4,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,050 700 245 334 112 1PH8 main motors 936 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 709 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8165-F2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 53.0 289 104.0 6,500 9,000 10,000 4,000 3,050 700 1,500 46.0 293 104.0 Imax [A] M0 [Nm] I0 [A] 245 334 112 4,150 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 937 Technical data and characteristics 6.1 Induction motors Table 6- 710 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8165-F2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,000 60.0 287 103.0 6,500 9,000 10,000 4,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,050 700 245 334 112 1PH8 main motors 938 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 711 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8165-F2 nN [rpm] 2,200 PN [kW] 66.0 MN [Nm] 287 IN [A] 103.0 nmax1 nmax2 [rpm] 6,500 [rpm] 9,000 nmax3 [rpm] 10,000 nmax, Br [rpm] 4,000 n2 [rpm] 3,500 Mmax [Nm] 700 Imax [A] 245 M0 [Nm] 334 I0 [A] 112 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 939 Technical data and characteristics 6.1 Induction motors Table 6- 712 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8165-G2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] 2,000 53.0 253 110.0 6,500 9,000 10,000 4,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,500 600 250 334 140 1PH8 main motors 940 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 713 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8165-G2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] [rpm] [kW] [Nm] [A] 2,300 60.0 249 107.0 2,000 53.0 253 110.0 1,500 45.1 287 112.0 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 600 250 334 140 3,000 6,500 9,000 10,000 4,000 4,000 5,150 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 941 Technical data and characteristics 6.1 Induction motors Table 6- 714 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8165-G2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,650 65.0 234 100.0 6,500 9,000 10,000 4,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,000 600 250 334 140 1PH8 main motors 942 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 715 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8165-G2 nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,800 68.0 232 100.0 6,500 9,000 10,000 4,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,500 600 250 334 140 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 943 Technical data and characteristics 6.1 Induction motors Table 6- 716 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8166-F2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] 1,500 52 331 116 6,500 9,000 10,000 4,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,000 730 250 353 127 1PH8 main motors 944 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 717 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8166-F2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 61 333 116 6,500 9,000 10,000 4,000 3,000 730 1,500 52 331 116 Imax [A] M0 [Nm] I0 [A] 250 353 127 4,050 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 945 Technical data and characteristics 6.1 Induction motors Table 6- 718 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8166-F2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,000 68 325 116 6,500 9,000 10,000 4,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,000 730 250 353 127 1PH8 main motors 946 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 719 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8166-F2 nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,200 75 326 116 6,500 9,000 10,000 4,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,500 730 250 353 127 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 947 Technical data and characteristics 6.1 Induction motors Table 6- 720 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8166-G2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] 2,000 64 306 125 6,500 9,000 10,000 4,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,000 600 241 353 147 1PH8 main motors 948 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 721 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8166-G2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 2,300 72 299 124 6,500 9,000 10,000 4,000 3,000 600 2,000 64 306 125 4,000 1,500 52 323 126 5,200 Imax [A] M0 [Nm] I0 [A] 241 353 147 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 949 Technical data and characteristics 6.1 Induction motors Table 6- 722 SINAMICS, 3-ph. 480 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8166-G2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,650 83 299 125 6,500 9,000 10,000 4,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,000 600 241 353 147 1PH8 main motors 950 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 723 SINAMICS, 3-ph. 480 VAC, Active Line Module, (ALM), 1PH8166-G2 nN PN MN IN nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] 2,800 87 297 124 6,500 9,000 10,000 4,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,500 600 241 353 147 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 951 Technical data and characteristics 6.1 Induction motors 6.1.3.6 Shaft height 180 - water-cooled Table 6- 724 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8184-B2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 400 17 406 50 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 5,000 7,500 - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,500 812 100 406 50 1PH8 main motors 952 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 725 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8184-B2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 500 23 439 54 400 18 439 54 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 5,000 7,500 - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,800 879 108 439 54 2,500 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 953 Technical data and characteristics 6.1 Induction motors Table 6- 726 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8184-B2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 600 29 462 55 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 5,000 7,500 - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,800 923 110 462 55 1PH8 main motors 954 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 727 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8184-C2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 700 33 450 77 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 5,000 7,500 - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,500 900 154 450 77 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 955 Technical data and characteristics 6.1 Induction motors Table 6- 728 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8184-C2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 800 38 454 77 700 33 454 77 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 5,000 7,500 - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,900 907 154 454 77 3,300 1PH8 main motors 956 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 729 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8184-C2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 1,000 48 458 77 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 5,000 7,500 - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,100 917 154 458 77 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 957 Technical data and characteristics 6.1 Induction motors Table 6- 730 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8184-D2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 1,000 47 449 114 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 5,000 7,500 - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 5,000 898 228 449 114 1PH8 main motors 958 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 731 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8184-D2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,150 54 448 112 5,000 7,500 - 3,500 5,000 897 1,000 47 448 112 Imax [A] M0 [Nm] I0 [A] 224 448 112 5,500 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 959 Technical data and characteristics 6.1 Induction motors Table 6- 732 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8184-D2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 1,350 64 453 112 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 5,000 7,500 - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 5,000 905 224 453 112 1PH8 main motors 960 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 733 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8184-F2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 1,500 70 446 150 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 5,000 7,500 - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 5,000 891 300 446 150 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 961 Technical data and characteristics 6.1 Induction motors Table 6- 734 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8184-F2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 82 447 150 5,000 7,500 - 3,500 5,000 895 1,500 70 447 150 Imax [A] M0 [Nm] I0 [A] 300 447 150 4,000 1PH8 main motors 962 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 735 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8184-F2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 2,000 95 454 152 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 5,000 7,500 - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 5,000 907 304 454 152 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 963 Technical data and characteristics 6.1 Induction motors Table 6- 736 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8184-L2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 2,500 95 363 196 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 5,000 7,500 - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 5,000 726 392 363 196 1PH8 main motors 964 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 737 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8184-L2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 2,900 102 336 182 5,000 7,500 - 3,500 5,000 672 2,500 88 336 182 Imax [A] M0 [Nm] I0 [A] 364 336 182 5,700 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 965 Technical data and characteristics 6.1 Induction motors Table 6- 738 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8184-L2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 3,400 100 281 158 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 5,000 7,500 - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 5,000 562 316 281 158 1PH8 main motors 966 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 739 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8186-B2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 400 23 549 68 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 5,000 7,500 - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,800 1,098 136 549 68 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 967 Technical data and characteristics 6.1 Induction motors Table 6- 740 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8186-B2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 500 30 573 70 400 24 573 70 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 5,000 7,500 - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 1,146 140 573 70 2,900 1PH8 main motors 968 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 741 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8186-B2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 600 38 605 73 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 5,000 7,500 - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,500 1,210 146 605 73 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 969 Technical data and characteristics 6.1 Induction motors Table 6- 742 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8186-C2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 700 43 587 97 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 5,000 7,500 - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,000 1,173 194 587 97 1PH8 main motors 970 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 743 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8186-C2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 800 49 585 99 700 43 585 99 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 5,000 7,500 - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,500 1,170 198 585 99 3,900 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 971 Technical data and characteristics 6.1 Induction motors Table 6- 744 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8186-C2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 1,000 61 583 98 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 5,000 7,500 - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,700 1,165 196 583 98 1PH8 main motors 972 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 745 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8186-D2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 1,000 64 611 148 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 5,000 7,500 - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 5,000 1,222 296 611 148 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 973 Technical data and characteristics 6.1 Induction motors Table 6- 746 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8186-D2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,150 74 615 148 5,000 7,500 - 3,500 5,000 1,229 1,000 64 615 148 Imax [A] M0 [Nm] I0 [A] 296 615 148 6,000 1PH8 main motors 974 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 747 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8186-D2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 1,350 86 608 148 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 5,000 7,500 - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 5,000 1,217 296 608 148 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 975 Technical data and characteristics 6.1 Induction motors Table 6- 748 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8186-F2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 1,500 93 592 198 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 5,000 7,500 - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 5,000 1,184 396 592 198 1PH8 main motors 976 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 749 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8186-F2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 111 606 200 5,000 7,500 - 3,500 5,000 1,211 1,500 95 606 200 Imax [A] M0 [Nm] I0 [A] 400 606 200 6,000 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 977 Technical data and characteristics 6.1 Induction motors Table 6- 750 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8186-F2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 2,000 126 602 200 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 5,000 7,500 - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 5,000 1,203 400 602 200 1PH8 main motors 978 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 751 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8186-L2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 2,500 120 458 250 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 5,000 7,500 - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 5,000 917 500 458 250 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 979 Technical data and characteristics 6.1 Induction motors Table 6- 752 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8186-L2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 2,900 135 445 245 5,000 7,500 - 3,500 5,000 889 2,500 116 445 245 Imax [A] M0 [Nm] I0 [A] 490 445 245 5,800 1PH8 main motors 980 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 753 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8186-L2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 3,400 121 340 200 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 5,000 7,500 - 3,500 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 5,000 680 400 340 200 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 981 Technical data and characteristics 6.1 Induction motors 6.1.3.7 Shaft height 225 - water-cooled Table 6- 754 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8224-B2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 400 36 859 100 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,400 1,719 200 859 100 1PH8 main motors 982 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 755 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8224-B2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 500 46 879 100 400 37 879 100 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,500 1,757 200 879 100 1,800 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 983 Technical data and characteristics 6.1 Induction motors Table 6- 756 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8224-B2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 600 53 844 94 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,900 1,687 188 844 94 1PH8 main motors 984 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 757 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8224-C2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 700 61 832 128 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,100 1,664 256 832 128 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 985 Technical data and characteristics 6.1 Induction motors Table 6- 758 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8224-C2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 800 70 836 130 700 61 836 130 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,300 1,671 260 836 130 2,500 1PH8 main motors 986 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 759 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8224-C2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 1,000 87 831 132 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,500 1,662 264 831 132 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 987 Technical data and characteristics 6.1 Induction motors Table 6- 760 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8224-D2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 1,000 89 850 188 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,800 1,700 376 850 188 1PH8 main motors 988 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 761 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8224-D2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,150 101 839 186 4,500 6,000 - 3,100 3,000 1,677 1,000 88 839 186 Imax [A] M0 [Nm] I0 [A] 372 839 186 3,600 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 989 Technical data and characteristics 6.1 Induction motors Table 6- 762 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8224-D2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 1,350 115 813 180 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,400 1,627 360 814 180 1PH8 main motors 990 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 763 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8224-F2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 1,500 119 758 240 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,500 1,515 480 758 240 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 991 Technical data and characteristics 6.1 Induction motors Table 6- 764 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8224-F2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 138 753 240 4,500 6,000 - 3,100 3,800 1,506 1,500 118 753 240 Imax [A] M0 [Nm] I0 [A] 480 753 240 4,500 1PH8 main motors 992 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 765 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8224-F2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 2,000 155 740 235 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,200 1,480 470 740 235 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 993 Technical data and characteristics 6.1 Induction motors Table 6- 766 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8224-L2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 2,500 153 584 310 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,200 1,169 620 584 310 1PH8 main motors 994 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 767 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8224-L2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 2,900 164 540 285 4,500 6,000 - 3,100 3,600 1,080 2,500 141 540 285 Imax [A] M0 [Nm] I0 [A] 570 540 285 4,500 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 995 Technical data and characteristics 6.1 Induction motors Table 6- 768 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8224-L2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 3,400 164 461 255 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,100 921 510 461 255 1PH8 main motors 996 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 769 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8226-B2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 400 47 1,122 130 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,600 2,244 260 1,122 130 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 997 Technical data and characteristics 6.1 Induction motors Table 6- 770 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8226-B2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 500 59 1,127 128 400 47 1,127 128 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,700 2,254 256 1,127 128 2,000 1PH8 main motors 998 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 771 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8226-B2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 600 70 1,114 122 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,000 2,228 244 1,114 122 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 999 Technical data and characteristics 6.1 Induction motors Table 6- 772 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8226-C2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 700 81 1,105 184 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,300 2,210 368 1,105 184 1PH8 main motors 1000 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 773 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8226-C2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 800 93 1,110 186 700 81 1,110 186 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,500 2,220 372 1,110 186 2,700 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1001 Technical data and characteristics 6.1 Induction motors Table 6- 774 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8226-C2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 1,000 116 1,108 184 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,700 2,216 368 1,108 184 1PH8 main motors 1002 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 775 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8226-D2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 1,000 115 1,098 235 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,400 2,197 470 1,098 235 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1003 Technical data and characteristics 6.1 Induction motors Table 6- 776 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8226-D2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,150 131 1,088 230 4,500 6,000 - 3,100 2,700 2,176 1,000 114 1,088 230 Imax [A] M0 [Nm] I0 [A] 460 1,088 230 3,300 1PH8 main motors 1004 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 777 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8226-D2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 1,350 150 1,061 225 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,200 2,122 450 1,061 225 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1005 Technical data and characteristics 6.1 Induction motors Table 6- 778 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8226-F2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 1,500 145 923 295 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,700 1,846 590 923 295 1PH8 main motors 1006 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 779 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8226-F2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 169 922 295 4,500 6,000 - 3,100 3,900 1,845 1,500 145 922 295 Imax [A] M0 [Nm] I0 [A] 590 922 295 4,500 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1007 Technical data and characteristics 6.1 Induction motors Table 6- 780 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8226-F2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 2,000 191 912 290 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,100 1,824 580 912 290 1PH8 main motors 1008 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 781 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8226-L2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 2,500 185 707 380 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,200 1,413 760 707 380 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1009 Technical data and characteristics 6.1 Induction motors Table 6- 782 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8226-L2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 2,900 204 672 360 4,500 6,000 - 3,100 3,600 1,343 2,500 176 672 360 Imax [A] M0 [Nm] I0 [A] 720 672 360 4,500 1PH8 main motors 1010 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 783 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8226-L2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 3,400 199 559 310 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,100 1,118 620 559 310 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1011 Technical data and characteristics 6.1 Induction motors Table 6- 784 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8228-B2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 400 58 1,385 154 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,700 2,769 308 1,385 154 1PH8 main motors 1012 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 785 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8228-B2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 500 72 1,375 150 400 58 1,375 150 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,800 2,750 300 1,375 150 2,100 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1013 Technical data and characteristics 6.1 Induction motors Table 6- 786 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8228-B2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 600 85 1,353 148 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,100 2,706 296 1,353 148 1PH8 main motors 1014 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 787 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8228-C2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 700 96 1,310 210 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,500 2,619 420 1,310 210 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1015 Technical data and characteristics 6.1 Induction motors Table 6- 788 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8228-C2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 800 110 1,313 210 700 96 1,313 210 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,700 2,626 420 1,313 210 2,900 1PH8 main motors 1016 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 789 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8228-C2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 1,000 138 1,318 210 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,900 2,636 420 1,318 210 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1017 Technical data and characteristics 6.1 Induction motors Table 6- 790 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8228-D2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 1,000 141 1,346 280 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,300 2,693 560 1,346 280 1PH8 main motors 1018 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 791 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8228-D2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,150 161 1,337 280 4,500 6,000 - 3,100 2,500 2,674 1,000 140 1,337 280 Imax [A] M0 [Nm] I0 [A] 560 1,337 280 3,200 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1019 Technical data and characteristics 6.1 Induction motors Table 6- 792 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8228-D2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 1,350 184 1,302 270 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,000 2,603 540 1,302 270 1PH8 main motors 1020 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 793 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8228-F2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 1,500 192 1,222 390 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,700 2,445 780 1,222 390 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1021 Technical data and characteristics 6.1 Induction motors Table 6- 794 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8228-F2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 221 1,206 390 4,500 6,000 - 3,100 3,900 2,412 1,500 189 1,206 390 Imax [A] M0 [Nm] I0 [A] 780 1,206 390 5,100 1PH8 main motors 1022 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 795 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8228-F2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 2,000 245 1,170 380 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,100 2,340 760 1,170 380 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1023 Technical data and characteristics 6.1 Induction motors Table 6- 796 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8228-L2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 2,500 226 863 455 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,200 1,727 910 863 455 1PH8 main motors 1024 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 797 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8228-L2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 2,900 237 780 415 4,500 6,000 - 3,100 3,600 1,561 2,500 204 780 415 Imax [A] M0 [Nm] I0 [A] 830 780 415 4,500 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1025 Technical data and characteristics 6.1 Induction motors Table 6- 798 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8228-L2 nrated Prated Mrated Irated [rpm] [kW] [Nm] [A] 3,400 237 666 370 nmax1 nmax2 nmax3 nmax, Br [rpm] [rpm] [rpm] [rpm] 4,500 6,000 - 3,100 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,100 1,331 740 666 370 1PH8 main motors 1026 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors 6.1.3.8 Shaft height 280 - water-cooled Table 6- 799 SINAMICS, 3-ph. 400 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8284-B2 nrated Prated Mrated [rpm] [kW] [Nm] 400 71 1,695 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 170 3,300 - - - n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 4,238 425 1,695 170 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1027 Technical data and characteristics 6.1 Induction motors Table 6- 800 SINAMICS, 3-ph. 400 V AC, Active Line Module, (ALM), 1PH8284-B2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] 500 89 1,700 [A] [rpm] [rpm] [rpm] [rpm] 172 3,300 - - - 400 71 1,700 172 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 4,250 430 1,700 172 3,100 1PH8 main motors 1028 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 801 SINAMICS, 3-ph. 480 V AC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8284-B2 nrated Prated Mrated [rpm] [kW] [Nm] 600 107 1,703 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 170 3,300 - - - n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 4,258 425 1,703 170 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1029 Technical data and characteristics 6.1 Induction motors Table 6- 802 SINAMICS, 3-ph. 400 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8284-C2 nrated Prated Mrated [rpm] [kW] [Nm] 700 123 1,678 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 260 3,300 - - - n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 4,195 650 1,678 260 1PH8 main motors 1030 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 803 SINAMICS, 3-ph. 400 V AC, Active Line Module, (ALM), 1PH8284-C2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] 800 141 1,683 [A] [rpm] [rpm] [rpm] [rpm] 260 3,300 - - - 700 123 1,683 260 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 4,208 650 1,683 260 3,100 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1031 Technical data and characteristics 6.1 Induction motors Table 6- 804 SINAMICS, 3-ph. 480 V AC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8284-C2 nrated Prated Mrated [rpm] [kW] [Nm] 1,000 176 1,681 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 265 3,300 - - - n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 4,202 663 1,681 265 1PH8 main motors 1032 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 805 SINAMICS, 3-ph. 400 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8284-D2 nrated Prated Mrated [rpm] [kW] [Nm] 1,000 172 1,643 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 350 3,300 - - - n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 4,107 875 1,643 350 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1033 Technical data and characteristics 6.1 Induction motors Table 6- 806 SINAMICS, 3-ph. 400 V AC, Active Line Module, (ALM), 1PH8284-D2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,150 198 1,644 355 3,300 - - - 2,200 4,111 1,000 172 1,644 355 Imax [A] M0 [Nm] I0 [A] 888 1,644 355 2,800 1PH8 main motors 1034 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 807 SINAMICS, 3-ph. 480 V AC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8284-D2 nrated Prated Mrated [rpm] [kW] [Nm] 1,350 232 1,641 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 355 3,300 - - - n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 4,103 888 1,641 355 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1035 Technical data and characteristics 6.1 Induction motors Table 6- 808 SINAMICS, 3-ph. 400 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8284-F2 nrated Prated Mrated [rpm] [kW] [Nm] 1,500 227 1,445 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 445 3,300 - - - n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 3,613 1,113 1,445 445 1PH8 main motors 1036 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 809 SINAMICS, 3-ph. 400 V AC, Active Line Module, (ALM), 1PH8284-F2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 265 1,446 445 3,300 - - - 2,200 3,615 1,500 227 1,446 445 Imax [A] M0 [Nm] I0 [A] 1,113 1,446 445 2,700 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1037 Technical data and characteristics 6.1 Induction motors Table 6- 810 SINAMICS, 3-ph. 480 V AC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8284-F2 nrated Prated Mrated [rpm] [kW] [Nm] 2,000 303 1,447 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 445 3,300 - - - n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,300 3,617 1,113 1,447 445 1PH8 main motors 1038 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 811 SINAMICS, 3-ph. 690 V AC, Basic Line Module, (BLM), 1PH8284-H2 nrated Prated Mrated [rpm] [kW] [Nm] 400 68 1,624 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 89 3,300 - - - n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,000 4,059 223 1,624 89 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1039 Technical data and characteristics 6.1 Induction motors Table 6- 812 SINAMICS, 3-ph. 690 V AC, Active Line Module, (ALM), 1PH8284-H2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] 500 85 1,624 [A] [rpm] [rpm] [rpm] [rpm] 89 3,300 - - - 400 68 1,624 89 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,000 4,059 223 1,624 89 2,600 1PH8 main motors 1040 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 813 SINAMICS, 3-ph. 690 V AC, Basic Line Module, (BLM), 1PH8284-K2 nrated Prated Mrated [rpm] [kW] [Nm] 700 119 1,624 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 136 3,300 - - - n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 4,059 340 1,624 136 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1041 Technical data and characteristics 6.1 Induction motors Table 6- 814 SINAMICS, 3-ph. 690 V AC, Active Line Module, (ALM), 1PH8284-K2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] 800 137 1,635 [A] [rpm] [rpm] [rpm] [rpm] 138 3,300 - - - 700 120 1,635 138 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 4,089 345 1,635 138 2,900 1PH8 main motors 1042 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 815 SINAMICS, 3-ph. 690 V AC, Basic Line Module, (BLM), 1PH8284-U2 nrated Prated Mrated [rpm] [kW] [Nm] 1,000 167 1,595 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 196 3,300 - - - n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 3,987 490 1,595 196 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1043 Technical data and characteristics 6.1 Induction motors Table 6- 816 SINAMICS, 3-ph. 690 V AC, Active Line Module, (ALM), 1PH8284-U2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,150 192 1,594 198 3,300 - - - 2,200 3,986 1,000 167 1,594 198 Imax [A] M0 [Nm] I0 [A] 495 1,594 198 2,800 1PH8 main motors 1044 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 817 SINAMICS, 3-ph. 690 V AC, Basic Line Module, (BLM), 1PH8284-W2 nrated Prated Mrated [rpm] [kW] [Nm] 1,500 220 1,401 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 250 3,300 - - - n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 3,502 625 1,401 250 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1045 Technical data and characteristics 6.1 Induction motors Table 6- 818 SINAMICS, 3-ph. 690 V AC, Active Line Module, (ALM), 1PH8284-W2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 257 1,402 250 3,300 - - - 2,200 3,506 1,500 220 1,402 250 Imax [A] M0 [Nm] I0 [A] 625 1,402 250 2,700 1PH8 main motors 1046 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 819 SINAMICS, 3-ph. 400 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8286-B2 nrated Prated Mrated [rpm] [kW] [Nm] 400 89 2,125 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 210 3,300 - - - n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 5,312 525 2,125 210 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1047 Technical data and characteristics 6.1 Induction motors Table 6- 820 SINAMICS, 3-ph. 400 V AC, Active Line Module, (ALM), 1PH8286-B2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] 500 111 2,120 [A] [rpm] [rpm] [rpm] [rpm] 205 3,300 - - - 400 89 2,120 205 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 5,300 513 2,120 205 3,300 1PH8 main motors 1048 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 821 SINAMICS, 3-ph. 480 V AC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8286-B2 nrated Prated Mrated [rpm] [kW] [Nm] 600 133 2,117 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 205 3,300 - - - n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 5,292 513 2,117 205 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1049 Technical data and characteristics 6.1 Induction motors Table 6- 822 SINAMICS, 3-ph. 400 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8286-C2 nrated Prated Mrated [rpm] [kW] [Nm] 700 153 2,087 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 320 3,300 - - - n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 5,218 800 2,087 320 1PH8 main motors 1050 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 823 SINAMICS, 3-ph. 400 V AC, Active Line Module, (ALM), 1PH8286-C2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] 800 175 2,089 [A] [rpm] [rpm] [rpm] [rpm] 320 3,300 - - - 700 153 2,089 320 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 5,223 800 2,089 320 3,100 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1051 Technical data and characteristics 6.1 Induction motors Table 6- 824 SINAMICS, 3-ph. 480 V AC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8286-C2 nrated Prated Mrated [rpm] [kW] [Nm] 1,000 219 2,091 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 325 3,300 - - - n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 5,229 813 2,091 325 1PH8 main motors 1052 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 825 SINAMICS, 3-ph. 400 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8286-D2 nrated Prated Mrated [rpm] [kW] [Nm] 1,000 214 2,044 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 460 3,300 - - - n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 5,109 1,150 2,044 460 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1053 Technical data and characteristics 6.1 Induction motors Table 6- 826 SINAMICS, 3-ph. 400 V AC, Active Line Module, (ALM), 1PH8286-D2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,150 246 2,043 455 3,300 - - - 2,200 5,107 1,000 214 2,043 455 Imax [A] M0 [Nm] I0 [A] 1,138 2,043 455 2,800 1PH8 main motors 1054 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 827 SINAMICS, 3-ph. 480 V AC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8286-D2 nrated Prated Mrated [rpm] [kW] [Nm] 1,350 289 2,044 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 460 3,300 - - - n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,300 5,111 1,150 2,044 460 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1055 Technical data and characteristics 6.1 Induction motors Table 6- 828 SINAMICS, 3-ph. 400 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8286-F2 nrated Prated Mrated [rpm] [kW] [Nm] 1,500 281 1,789 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 540 3,300 - - - n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 4,473 1,350 1,789 540 1PH8 main motors 1056 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 829 SINAMICS, 3-ph. 400 V AC, Active Line Module, (ALM), 1PH8286-F2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 328 1,790 540 3,300 - - - 2,300 4,475 1,500 281 1,790 540 Imax [A] M0 [Nm] I0 [A] 1,350 1,790 540 2,800 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1057 Technical data and characteristics 6.1 Induction motors Table 6- 830 SINAMICS, 3-ph. 480 V AC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8286-F2 nrated Prated Mrated [rpm] [kW] [Nm] 2,000 375 1,791 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 550 3,300 - - - n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,400 4,477 1,375 1,791 550 1PH8 main motors 1058 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 831 SINAMICS, 3-ph. 690 V AC, Basic Line Module, (BLM), 1PH8286-H2 nrated Prated Mrated [rpm] [kW] [Nm] 400 85 2,029 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 108 3,300 - - 2,000 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,000 5,073 270 2,029 108 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1059 Technical data and characteristics 6.1 Induction motors Table 6- 832 SINAMICS, 3-ph. 690 V AC, Active Line Module, (ALM), 1PH8286-H2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] 500 106 2,025 [A] [rpm] [rpm] [rpm] [rpm] 108 3,300 - - - 400 85 2,025 108 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,000 5,062 270 2,025 108 2,600 1PH8 main motors 1060 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 833 SINAMICS, 3-ph. 690 V AC, Basic Line Module, (BLM), 1PH8286-K2 nrated Prated Mrated [rpm] [kW] [Nm] 700 148 2,019 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 174 3,300 - - - n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 5,048 435 2,019 174 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1061 Technical data and characteristics 6.1 Induction motors Table 6- 834 SINAMICS, 3-ph. 690 V AC, Active Line Module, (ALM), 1PH8286-K2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] 800 170 2,029 [A] [rpm] [rpm] [rpm] [rpm] 176 3,300 - - - 700 149 2,029 176 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 5,073 440 2,029 176 3,100 1PH8 main motors 1062 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 835 SINAMICS, 3-ph. 690 V AC, Basic Line Module, (BLM), 1PH8286-U2 nrated Prated Mrated [rpm] [kW] [Nm] 1,000 208 1,986 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 260 3,300 - - - n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 4,966 650 1,986 260 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1063 Technical data and characteristics 6.1 Induction motors Table 6- 836 SINAMICS, 3-ph. 690 V AC, Active Line Module, (ALM), 1PH8286-U2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,150 239 1,985 260 3,300 - - - 2,200 4,962 1,000 208 1,985 260 Imax [A] M0 [Nm] I0 [A] 650 1,985 260 2,800 1PH8 main motors 1064 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 837 SINAMICS, 3-ph. 690 V AC, Basic Line Module, (BLM), 1PH8286-W2 nrated Prated Mrated [rpm] [kW] [Nm] 1,500 273 1,738 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 310 3,300 - - - n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 4,345 775 1,738 310 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1065 Technical data and characteristics 6.1 Induction motors Table 6- 838 SINAMICS, 3-ph. 690 V AC, Active Line Module, (ALM), 1PH8286-W2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 318 1,735 305 3,300 - - - 2,300 4,338 1,500 273 1,735 305 Imax [A] M0 [Nm] I0 [A] 763 1,735 305 2,800 1PH8 main motors 1066 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 839 SINAMICS, 3-ph. 400 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8288-B2 nrated Prated Mrated [rpm] [kW] [Nm] 400 109 2,602 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 260 3,300 - - - n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 6,506 650 2,602 260 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1067 Technical data and characteristics 6.1 Induction motors Table 6- 840 SINAMICS, 3-ph. 400 V AC, Active Line Module, (ALM), 1PH8288-B2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] 500 136 2,598 [A] [rpm] [rpm] [rpm] [rpm] 260 3,300 - - - 400 109 2,598 260 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 6,494 650 2,598 260 3,300 1PH8 main motors 1068 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 841 SINAMICS, 3-ph. 480 V AC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8288-B2 nrated Prated Mrated [rpm] [kW] [Nm] 600 164 2,610 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 260 3,300 - - - n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 6,526 650 2,610 260 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1069 Technical data and characteristics 6.1 Induction motors Table 6- 842 SINAMICS, 3-ph. 400 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8288-C2 nrated Prated Mrated [rpm] [kW] [Nm] 700 188 2,565 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 400 3,300 - - - n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 6,412 1,000 2,565 400 1PH8 main motors 1070 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 843 SINAMICS, 3-ph. 400 V AC, Active Line Module, (ALM), 1PH8288-C2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] 800 215 2,567 [A] [rpm] [rpm] [rpm] [rpm] 405 3,300 - - - 700 188 2,567 405 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 6,416 1,013 2,567 405 3,100 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1071 Technical data and characteristics 6.1 Induction motors Table 6- 844 SINAMICS, 3-ph. 480 V AC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8288-C2 nrated Prated Mrated [rpm] [kW] [Nm] 1,000 269 2,569 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 405 3,300 - - - n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 6,422 1,013 2,569 405 1PH8 main motors 1072 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 845 SINAMICS, 3-ph. 400 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8288-D2 nrated Prated Mrated [rpm] [kW] [Nm] 1,000 264 2,521 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 550 3,300 - - - n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 6,303 1,375 2,521 550 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1073 Technical data and characteristics 6.1 Induction motors Table 6- 846 SINAMICS, 3-ph. 400 V AC, Active Line Module, (ALM), 1PH8288-D2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,150 304 2,525 550 3,300 - - - 2,300 6,311 1,000 264 2,525 550 Imax [A] M0 [Nm] I0 [A] 1,375 2,525 550 2,900 1PH8 main motors 1074 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 847 SINAMICS, 3-ph. 480 V AC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8288-D2 nrated Prated Mrated [rpm] [kW] [Nm] 1,350 357 2,525 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 550 3,300 - - - n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,400 6,314 1,375 2,525 550 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1075 Technical data and characteristics 6.1 Induction motors Table 6- 848 SINAMICS, 3-ph. 400 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8288-F2 nrated Prated Mrated [rpm] [kW] [Nm] 1,500 345 2,197 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 660 3,300 - - - n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 5,491 1,650 2,197 660 1PH8 main motors 1076 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 849 SINAMICS, 3-ph. 400 V AC, Active Line Module, (ALM), 1PH8288-F2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 403 2,199 670 3,300 - - - 2,400 5,498 1,500 345 2,199 670 Imax [A] M0 [Nm] I0 [A] 1,675 2,199 670 2,800 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1077 Technical data and characteristics 6.1 Induction motors Table 6- 850 SINAMICS, 3-ph. 480 V AC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8288-F2 nrated Prated Mrated [rpm] [kW] [Nm] 2,000 460 2,197 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 670 3,300 - - - n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,500 5,491 1,675 2,197 670 1PH8 main motors 1078 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 851 SINAMICS, 3-ph. 690 V AC, Basic Line Module, (BLM), 1PH8288-H2 nrated Prated Mrated [rpm] [kW] [Nm] 400 105 2,507 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 134 3,300 - - - n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,000 6,267 335 2,507 134 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1079 Technical data and characteristics 6.1 Induction motors Table 6- 852 SINAMICS, 3-ph. 690 V AC, Active Line Module, (ALM), 1PH8288-H2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] 500 131 2,502 [A] [rpm] [rpm] [rpm] [rpm] 134 3,300 - - - 400 105 2,502 134 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,000 6,255 335 2,502 134 2,700 1PH8 main motors 1080 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 853 SINAMICS, 3-ph. 690 V AC, Basic Line Module, (BLM), 1PH8288-K2 nrated Prated Mrated [rpm] [kW] [Nm] 700 182 2,483 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 205 3,300 - - - n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 6,208 513 2,483 205 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1081 Technical data and characteristics 6.1 Induction motors Table 6- 854 SINAMICS, 3-ph. 690 V AC, Active Line Module, (ALM), 1PH8288-K2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br [rpm] [kW] [Nm] 800 209 2,495 [A] [rpm] [rpm] [rpm] [rpm] 205 3,300 - - - 700 183 2,495 205 n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 6,237 513 2,495 205 3,100 1PH8 main motors 1082 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 855 SINAMICS, 3-ph. 690 V AC, Basic Line Module, (BLM), 1PH8288-U2 nrated Prated Mrated [rpm] [kW] [Nm] 1,000 256 2,445 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 310 3,300 - - - n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 6,112 775 2,445 310 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1083 Technical data and characteristics 6.1 Induction motors Table 6- 856 SINAMICS, 3-ph. 690 V AC, Active Line Module, (ALM), 1PH8288-U2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,150 295 2,450 310 3,300 - - - 2,300 6,124 1,000 257 2,450 310 Imax [A] M0 [Nm] I0 [A] 775 2,450 310 2,900 1PH8 main motors 1084 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.1 Induction motors Table 6- 857 SINAMICS, 3-ph. 690 V AC, Basic Line Module, (BLM), 1PH8288-W2 nrated Prated Mrated [rpm] [kW] [Nm] 1,500 335 2,133 Irated nmax1 nmax2 nmax3 nmax, Br [A] [rpm] [rpm] [rpm] [rpm] 375 3,300 - - - n2 [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,200 5,332 938 2,133 375 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1085 Technical data and characteristics 6.1 Induction motors Table 6- 858 SINAMICS, 3-ph. 690 V AC, Active Line Module, (ALM), 1PH8288-W2 nrated Prated Mrated Irated nmax1 nmax2 nmax3 nmax, Br n2 [rpm] [kW] [Nm] [A] [rpm] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 391 2,134 375 3,300 - - - 2,400 5,334 1,500 335 2,134 375 Imax [A] M0 [Nm] I0 [A] 938 2,134 375 2,800 1PH8 main motors 1086 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors 6.2 Synchronous motors 6.2.1 Technical data The technical data of the relevant motor version are defined by four rated operating points in the tables. These four rated points also correspond to the data stamped on the rating plate of the motor and to the data listed in the selection and ordering data sections of catalog NC 62 and D21.4. Table 6- 859 Explanation of the abbreviations used Abbreviation Unit Description Prated kW Rated power Mrated Nm Rated torque Irated A Rated current Urated V Rated voltage frated Hz Rated frequency nrated rpm Rated speed M0 Nm Torque (S1) at zero speed I0 A Current (S1) at M0 - Maximum efficiency in S1 speed range (in range nopt) J kgm2 Moment of inertia Tth min Thermal time constant P_cool kW Heat loss to be dissipated on water-cooled motors m kg Weight nmax rpm Maximum permissible speed with bearing type "standard or increased speed" nmax,Br rpm Maximum permissible speed with bearing type "Advanced Lifetime" or built-on holding brake nmax,Inv rpm Maximum permissible operating speed based on the induced voltage in the motor and the voltage strength of the Motor Module (borders range without VPM (Voltage Protection Module) nopt rpm Speed at optimum operating point Popt kW Maximum possible power (S1) at the optimum operating point at speed nopt Mmax Nm Maximum permissible short-time torque for dynamic processes Imax A Maximum permissible short-time current at Mmax 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1087 Technical data and characteristics 6.2 Synchronous motors 6.2.1.1 Shaft height 132 - forced ventilation Table 6- 860 1PH8 shaft height 132, forced ventilation (basic data) Motor Module Prated Mrated Irated Urated frated nrated Mo Io J [kW] [Nm] [A] [V] [Hz] [rpm] [Nm] [A] [kgm2] 0.0446 1PH8131-2F SLM/BLM 400 V 15.7 100 29 388 50.0 1500 105 30 Y connection ALM 400 V 18.0 98 29 415 58.3 1750 105 30 0.947 SLM/BLM/ALM 480 V 19.9 95 29 449 66.7 2000 105 30 0.948 1PH8131-2L SLM/BLM 400 V 25.0 96 44 371 83.3 2500 105 48 0.948 Y connection ALM 400 V 27.7 95 44 415 93.3 2800 105 48 0.949 SLM/BLM/ALM 480 V 29.5 94 43 449 100 3000 105 48 0.951 1PH8133-2F SLM/BLM 400 V 19.9 127 44 316 50.0 1500 131 45 Y connection ALM 400 V 23.1 126 43 366 58.3 1750 131 45 0.950 SLM/BLM/ALM 480 V 26.2 125 43 415 66.7 2000 131 45 0.951 1PH8133-2L SLM/BLM 400 V 31.7 121 55 371 83, 3 2500 131 59 0.948 Y connection ALM 400 V 35.2 120 54 415 93, 3 2800 131 59 0.952 SLM/BLM/ALM 480 V 37.4 119 54 449 100 3000 131 59 1PH8135-2F SLM/BLM 400 V 23.7 151 43 383 50.0 1500 158 44 Y connection ALM 400 V 27.2 149 42 415 58.3 1750 158 44 0.952 SLM/BLM/ALM 480 V 30.2 144 42 449 66.7 2000 158 44 0.953 1PH8135-2G SLM/BLM 400 V 31.4 150 59 356 66.7 2000 158 63 0.953 Y connection ALM 400 V 35.6 148 59 407 76, 7 2300 158 63 0.953 SLM/BLM/ALM 480 V 40.2 145 58 449 88.3 2650 158 63 1PH8137-2F SLM/BLM 400 V 30.6 195 60 356 50.0 1500 203 62 Y connection ALM 400 V 35.6 194 59 412 58.3 1750 203 62 0.953 SLM/BLM/ALM 480 V 40.0 191 59 449 66.7 2000 203 62 0.954 1PH8137-2L SLM/BLM 400 V 48.4 185 83 371 83.3 2500 203 89 0.954 Y connection ALM 400 V 53.4 182 82 415 93.3 2800 203 89 0.953 SLM/BLM/ALM 480 V 56.9 181 81 449 100 3000 203 89 0.953 1PH8137-2M SLM/BLM 400 V 57.5 183 104 370 100 3000 203 115 0.953 Y connection ALM 400 V 62.2 180 102 405 110 3300 203 115 0.952 SLM/BLM/ALM 480 V 66.7 177 100 440 120 3600 203 115 0.950 6.2.1.2 0.0600 Tth m [min] [kg] 0.944 10 0.948 85 103 0.952 0.0750 0.952 120 0.952 0.0885 0.952 136 Shaft height 160 - forced ventilation Table 6- 861 1PH8 shaft height 160, forced ventilation (basic data) Motor Module Prated Mrated Irated Urated frated nrated Mo Io J [kW] [Nm] [A] [V] [Hz] [rpm] [Nm] [A] [kgm2] 0.216 Tth [min] 1PH8165-2F SLM/BLM 400 V 61 390 119 340 100 1500 440 126 0.940 10 Y connection ALM 400 V 69 375 115 395 117 1750 440 126 0.943 SLM/BLM/ALM 480 V 74 355 110 445 133 2000 440 126 0.946 1PH8165-2L SLM/BLM 400 V 84 320 148 370 167 2500 440 188 0.955 Y connection ALM 400 V 87 300 138 410 187 2800 440 188 0.959 SLM/BLM/ALM 480 V 89 285 131 440 200 3000 440 188 0.960 m [kg] 218 1PH8 main motors 1088 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Motor Module Prated Mrated Irated Urated frated nrated Mo Io J [kW] [Nm] [A] [V] [Hz] [rpm] [Nm] [A] [kgm2] 0.244 1PH8167-2F SLM/BLM 400 V 69 435 133 345 100 1500 500 143 Y connection ALM 400 V 77 420 128 400 117 1750 500 143 0.943 SLM/BLM/ALM 480 V 82 395 123 450 133 2000 500 143 0.946 1PH8167-2L SLM/BLM 400 V 95 360 177 350 167 2500 500 230 0.955 Y connection ALM 400 V 98 335 164 385 187 2800 500 230 0.959 SLM/BLM/ALM 480 V 99 315 155 410 200 3000 500 230 0.960 6.2.1.3 Tth m [min] [kg] 0.940 240 Shaft height 180 - forced ventilation Table 6- 862 1PH8 SH 180, forced ventilation (basic data) Motor Module Prated Mrated Irated Urated frated nrated Mo Io J [kW] [Nm] [A] [V] [Hz] [rpm] [Nm] [A] [kgm2] 0.460 1PH8184-2C SLM/BLM 400 V 33 450 80 278 47.0 700 480 84 Y connection ALM 400 V m [min] [kg] 0.932 38 454 80 316 53.0 800 480 84 0.926 SLM/BLM/ALM 480 V 46 439 78 390 67.0 1000 480 84 0.937 1PH8184-2D SLM/BLM 400 V 46 439 106 285 67.0 1000 480 115 0.937 Y connection ALM 400 V 53 440 106 327 77.0 1150 480 115 0.942 SLM/BLM/ALM 480 V 62 439 106 382 90.0 1350 480 115 0.946 1PH8184-2F SLM/BLM 400 V 70 446 148 308 100 1500 480 157 0.951 Y connection ALM 400 V 82 447 150 359 117 1750 480 157 0.954 SLM/BLM/ALM 480 V 86 411 138 404 133 2000 480 157 1PH8186-2C SLM/BLM 400 V 44 600 108 269 47.0 700 640 115 Y connection ALM 400 V 50 597 108 306 53.0 800 640 115 0.931 18 330 330 330 0.957 0.600 0.924 SLM/BLM/ALM 480 V 62 592 108 379 67.0 1000 640 115 0.941 1PH8186-2D SLM/BLM 400 V 62 592 148 275 67.0 1000 640 157 0.943 Y connection ALM 400 V 71 590 148 315 77.0 1150 640 157 0.948 SLM/BLM/ALM 480 V 83 587 146 368 90.0 1350 640 157 0.952 1PH8186-2F SLM/BLM 400 V 93 592 215 282 100 1500 640 229 0.952 Y connection ALM 400 V 109 595 215 328 117 1750 640 229 0.955 SLM/BLM/ALM 480 V 115 549 200 370 133 2000 640 229 0.956 6.2.1.4 Tth 21 400 400 405 Shaft height 225 - forced ventilation Table 6- 863 1PH8 SH 225, forced ventilation (basic data) Motor Module Prated Mrated Irated Urated frated nrated Mo Io J [kW] [Nm] [A] [V] [Hz] [rpm] [Nm] [A] [kgm2] 1.28 Tth m [min] [kg] 1PH8224-2C SLM/BLM 400 V 48 655 120 256 47.0 700 708 128 Y connection ALM 400 V 55 657 120 292 53.0 800 708 128 0.961 0.962 SLM/BLM/ALM 480 V 68 649 118 363 67.0 1000 708 128 0.965 1PH8224-2D SLM/BLM 400 V 68 649 170 254 67.0 1000 708 183 0.964 Y connection ALM 400 V 78 648 170 292 77.0 1150 708 183 0.965 23 580 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1089 Technical data and characteristics 6.2 Synchronous motors Motor Module Prated Mrated Irated Urated frated nrated Mo Io J [kW] [Nm] [A] [V] [Hz] [rpm] [Nm] [A] [kgm2] SLM/BLM/ALM 480 V 91 644 168 342 90.0 1350 708 183 0.965 1PH8224-2F SLM/BLM 400 V 101 643 235 271 100 1500 708 256 0.965 Y connection ALM 400 V 117 638 235 315 117 1750 708 256 0.965 SLM/BLM/ALM 480 V 118 563 210 355 133 2000 708 256 0.963 1PH8226-2C SLM/BLM 400 V 64 873 170 238 47.0 700 944 183 Y connection ALM 400 V 73 871 170 271 53.0 800 944 183 0.965 SLM/BLM/ALM 480 V 91 869 170 338 67.0 1000 944 183 0.967 1PH8226-2D SLM/BLM 400 V 91 869 215 265 67.0 1000 944 233 0.967 Y connection ALM 400 V 104 864 215 304 77.0 1150 944 233 0.967 SLM/BLM/ALM 480 V 121 856 215 356 90.0 1350 944 233 0.968 1PH8226-2F SLM/BLM 400 V 134 853 295 288 100 1500 944 320 0.967 Y connection ALM 400 V 156 851 295 335 117 1750 944 320 0.966 SLM/BLM/ALM 480 V 157 750 260 378 133 2000 944 320 0.964 1PH8228-2C SLM/BLM 400 V 80 1091 200 254 47.0 700 1180 213 Y connection ALM 400 V 91 1086 198 290 53.0 800 1180 213 0.967 SLM/BLM/ALM 480 V 113 1079 198 361 67.0 1000 1180 213 0.968 1PH8228-2D SLM/BLM 400 V 113 1079 265 271 67.0 1000 1180 284 0.968 Y connection ALM 400 V 129 1071 260 311 77.0 1150 1180 284 0.969 SLM/BLM/ALM 480 V 151 1068 260 364 90.0 1350 1180 284 0.968 1PH8228-2F SLM/BLM 400 V 168 1070 395 270 100 1500 1180 427 0.967 Y connection ALM 400 V 195 1064 390 314 117 1750 1180 427 0.966 936 345 355 133 2000 1180 427 0.964 SLM/BLM/ALM 480 V 196 6.2.1.5 1.66 2.02 Tth m [min] [kg] 0.963 0.965 26 700 28 810 Overload factors for intermittent duty types (S6) and short-time duty (S2) The specified overload factors for intermittent duty types (S6) and for short-time duty (S2) are based on the S1 characteristic (continuous operation) of the relevant motor. Table 6- 864 S6/S2 overload factors for forced-ventilated synchronous motors Motor type Overload factors S6 - 60% S6 - 40% S6 - 25% S2 - 30 min 1PH813-20/1 1.20 1.35 1.40 1.15 1PH816-20/1 1.20 1.35 1.40 1.15 1PH818-20/1 1.10 1.20 1.25 1.07 1PH822-20/1 1.10 1.25 1.30 1.30 1PH8 main motors 1090 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors 6.2.1.6 Shaft height 132 - water-cooled Table 6- 865 1PH8 shaft height 132, water cooling (basic data) Motor Module Prat- Mrate Irated Urat- frated nrated Mo Io ed d [A] ed [Hz] [rpm] [Nm] [A] [kW] [Nm] [V] J Tth P_cool m [kgm2] [min] [kW] [kg] 1.6 102 1PH81312F2 SLM/BLM 400 V 17.6 112 40 326 50.0 1,500 115 41 0.946 Y connection ALM 400 V 20.4 112 40 377 58.3 1,750 115 41 0.947 1.8 SLM/BLM/ALM 480 V 23.2 111 39 427 66.7 2,000 115 41 0.948 1.9 1PH81312L2 SLM/BLM 400 V 28.5 109 57 359 83.3 2,500 115 60 0.948 2.3 Y connection ALM 400 V 31.7 108 56 400 93.3 2,800 115 60 0.949 2.5 SLM/BLM/ALM 480 V 33.6 107 56 427 100 3,000 115 60 0.950 2.7 SLM/BLM 400 V 23.1 147 42 371 50.0 1,500 155 43 0.947 ALM 400 V 26.4 144 42 415 58.3 1,750 155 43 0.948 2.4 SLM/BLM/ALM 480 V 29.0 139 41 449 66.7 2,000 155 43 0.949 2.5 1PH81332G2 SLM/BLM 400 V 30.6 146 57 383 66.7 2,000 155 61 0.950 2.5 Y connection ALM 400 V 34.9 145 57 415 76.7 2,300 155 61 0.951 2.8 SLM/BLM/ALM 480 V 39.1 141 57 449 88.3 2,650 155 61 0.952 3.1 SLM/BLM 400 V 29.7 189 57 384 50.0 1,500 196 59 0.950 2.7 ALM 400 V 34.1 186 56 395 58.3 1,750 196 59 0.951 3.1 SLM/BLM/ALM 480 V 37.9 181 56 449 66.7 2,000 196 59 0.952 3.2 1PH81352G2 SLM/BLM 400 V 39.0 186 81 346 66.7 2,000 196 85 0.952 Y connection ALM 400 V 44.3 184 80 395 76.7 2,300 196 85 0.953 3.5 SLM/BLM/ALM 480 V 50.5 182 79 452 88.3 2,650 196 85 0.954 4.0 1PH81372F2 SLM/BLM 400 V 32.7 208 58 371 50.0 1,500 226 60 0.951 Y connection ALM 400 V 37.0 202 57 415 58.3 1,750 226 60 0.952 3.3 SLM/BLM/ALM 480 V 40.6 194 57 449 66.7 2,000 226 60 0.953 3.4 SLM/BLM 400 V 44.4 212 85 371 66.7 2,000 226 90 0.954 3.6 ALM 400 V 50.8 210 84 424 76.7 2,300 226 90 0.956 4.1 SLM/BLM/ALM 480 V 56.8 205 83 449 88.3 2,650 226 90 0.954 4.5 1PH81382F2 SLM/BLM 400 V 44.9 286 118 316 50.0 1,500 290 120 0.958 4.0 Y connection ALM 400 V 52.4 286 118 366 58.3 1,750 290 120 0.959 4.7 SLM/BLM/ALM 480 V 59.7 285 118 416 66.7 2,000 290 120 0.960 4.8 1PH81382G2 SLM/BLM 400 V 59.3 283 131 374 66.7 2,000 290 133 0.960 4.7 Y connection ALM 400 V 67.7 281 130 415 76.7 2,300 290 133 0.961 5.4 SLM/BLM/ALM 480 V 76.3 275 130 449 88.3 2,650 290 133 0.962 6.1 1PH81332F2 Y connection 1PH81352F2 Y connection 1PH81372G2 Y connection 0.0446 5 0.0600 0.0750 0.0885 2.1 120 138 3.1 2.9 153 156 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1091 Technical data and characteristics 6.2 Synchronous motors 6.2.1.7 Shaft height 160 - water cooling Table 6- 866 1PH8 shaft height 160, water cooling (basic data) Motor Module Prat- Mrate Irated Urat- frated nrated Mo Io ed d [A] ed [Hz] [rpm] [Nm] [A] [kW] [Nm] [V] J Tth P_cool m [kgm2] 4.7 224 SLM/BLM 400 V 59 375 111 380 100 1500 440 118 0.940 Y connection ALM 400 V 67 365 108 440 117 1750 440 118 0.943 5.3 SLM/BLM/ALM 480 V 70 330 105 500 133 2000 440 118 0.946 5.6 1PH81642L2 SLM/BLM 400 V 88 335 165 355 167 2500 440 205 0.955 6.2 Y connection ALM 400 V 93 315 156 395 187 2800 440 205 0.959 6.5 SLM/BLM/ALM 480 V 96 305 150 420 200 3000 440 205 0.960 6.7 SLM/BLM 400 V 74 475 148 355 100 1500 550 159 0.940 ALM 400 V 85 460 143 410 117 1750 550 159 0.943 6.6 SLM/BLM/ALM 480 V 89 425 138 465 133 2000 550 159 0.946 7.2 1PH81662L2 SLM/BLM 400 V 102 390 188 380 167 2500 550 240 0.955 7.1 Y connection ALM 400 V 109 375 177 420 187 2800 550 240 0.959 7.5 SLM/BLM/ALM 480 V 110 350 169 450 200 3000 550 240 0.960 7.7 SLM/BLM 400 V 84 530 169 355 100 1500 620 179 0.940 ALM 400 V 94 510 164 410 117 1750 620 179 0.943 7.5 SLM/BLM/ALM 480 V 100 480 157 465 133 2000 620 179 0.946 8.0 1PH81682L2 SLM/BLM 400 V 119 455 225 355 167 2500 520 240 0.955 8.3 Y connection ALM 400 V 123 420 210 395 187 2800 520 240 0.959 8.6 SLM/BLM/ALM 480 V 125 395 197 420 200 3000 520 240 0.960 8.8 Y connection 1PH81682F2 Y connection 6.2.1.8 5 [kg] 1PH81642F2 1PH81662F2 0.175 [kW] 0.216 0.244 6.0 5 6.7 257 279 Shaft height 180 - water-cooled Table 6- 867 1PH8 shaft height 180, water cooling (basic data) Motor Module Prat- Mrate Irated Urat- frated nrated Mo Io ed d [A] ed [Hz] [rpm] [Nm] [A] [kW] [Nm] [V] J Tth P_cool m [kgm2] [min] [kW] [kg] 0.45 13 3.8 330 1PH81842C2 SLM/BLM 400 V 42 573 100 303 47.0 700 590 103 0.919 Y connection ALM 400 V 48 573 102 342 53.0 800 590 103 0.926 4.4 SLM/BLM/ALM 480 V 60 573 102 423 67.0 1000 590 103 0.937 5.6 1PH81842D2 SLM/BLM 400 V 61 583 140 313 67.0 1000 600 143 0.937 5.7 Y connection ALM 400 V 70 581 140 386 77.0 1150 600 143 0.942 6.5 SLM/BLM/ALM 480 V 82 580 140 417 90.0 1350 600 143 0.946 7.7 SLM/BLM 400 V 90 573 190 334 100 1500 600 196 0.951 8.5 ALM 400 V 103 562 186 386 117 1750 600 196 0.954 9.7 SLM/BLM/ALM 480 V 110 525 176 434 133 2000 600 196 0.957 10.4 SLM/BLM 400 V 127 485 260 328 167 2500 530 278 0.957 12.0 ALM 400 V 140 461 250 375 193 2900 530 278 0.956 13.2 1PH81842F2 Y connection 1PH81842L2 330 330 332 1PH8 main motors 1092 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Motor Module Prat- Mrate Irated Urat- frated nrated Mo Io ed d [A] ed [Hz] [rpm] [Nm] [A] [kW] [Nm] [V] J Tth P_cool m [kgm2] [min] [kW] Y connection SLM/BLM/ALM 480 V 142 424 230 405 213 3200 530 278 0.954 1PH81862C2 SLM/BLM 400 V 58 791 142 295 47.0 700 800 143 0.924 Y connection ALM 400 V 66 788 142 335 53.0 800 800 143 0.931 6.1 SLM/BLM/ALM 480 V 82 783 140 415 67.0 1000 800 143 0.941 7.6 SLM/BLM 400 V 80 764 190 300 67.0 1000 800 196 0.943 7.5 ALM 400 V 92 764 190 345 77.0 1150 800 196 0.948 8.6 SLM/BLM/ALM 480 V 107 757 190 400 90.0 1350 800 196 0.952 10.1 1PH81862F2 SLM/BLM 400 V 119 758 275 305 100 1500 800 285 0.952 11.2 Y connection ALM 400 V 138 753 275 355 117 1750 800 285 0.955 13.0 SLM/BLM/ALM 480 V 154 735 265 400 133 2000 800 285 0.956 14.6 SLM/BLM 400 V 168 642 370 305 167 2500 720 405 0.957 15.9 ALM 400 V 178 586 340 345 193 2900 720 405 0.955 16.8 SLM/BLM/ALM 480 V 183 546 315 375 213 3200 720 405 0.953 17.3 1PH81862D2 Y connection 1PH81862L2 Y connection 6.2.1.9 [kg] 13.4 0.60 14 5.3 400 400 405 405 Shaft height 225 - water-cooled Table 6- 868 1PH8 shaft height 225, water cooling (basic data) Motor Module Prat- Mrated Irated Urat- frated nrated Mo Io ed [Nm] [A] ed [Hz] [rpm] [Nm] [A] [kW] [V] J Tth P_cool m [kgm2] [min] [kW] [kg] 1.28 16 6.7 580 1PH82242C2 SLM/BLM 400 V 72 982 180 275 47 700 1,007 183 0.947 Y connection ALM 400 V 81 967 178 310 53 800 1,007 183 0.952 7.6 SLM/BLM/ALM 480 V 101 964 178 385 67 1,000 1,007 183 0.957 9.6 1PH82242D2 SLM/BLM 400 V 101 964 255 275 67 1,000 1,007 262 0.956 9.6 Y connection ALM 400 V 115 955 250 310 77 1,150 1,007 262 0.959 10.9 SLM/BLM/ALM 480 V 135 955 250 365 90 1,350 1,007 262 0.961 12.8 SLM/BLM 400 V 151 961 355 290 100 1,500 1,007 367 0.962 14.4 ALM 400 V 175 955 355 335 117 1,750 1,007 367 0.963 16.7 SLM/BLM/ALM 480 V 186 888 330 380 133 1,350 1,007 367 0.964 17.7 1PH82242L2 SLM/BLM 400 V 182 695 365 320 167 2,500 885 460 0.961 17.3 Y connection ALM 400 V 191 629 335 370 193 2,900 885 460 0.958 18.1 SLM/BLM/ALM 480 V 196 585 310 400 213 3,200 885 460 0.954 18.5 1PH82262C2 SLM/BLM 400 V 95 1296 255 255 47 700 1,330 260 0.952 Y connection ALM 400 V 108 1289 255 287 53 800 1,330 260 0.956 10.2 SLM/BLM/ALM 480 V 134 1280 255 357 67 1,000 1,330 260 0.960 12.7 SLM/BLM 400 V 135 1289 325 285 67 1,000 1,330 330 0.960 12.8 ALM 400 V 155 1287 325 325 77 1,150 1,330 330 0.962 14.8 1PH82242F2 Y connection 1PH82262D2 1.66 18 8.9 700 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1093 Technical data and characteristics 6.2 Synchronous motors Motor Module Prat- Mrated Irated Urat- frated nrated Mo Io ed [Nm] [A] ed [Hz] [rpm] [Nm] [A] [kW] [V] J Tth P_cool m [kgm2] [min] [kW] Y connection SLM/BLM/ALM 480 V 180 1273 320 380 90 1,350 1,330 330 0.964 17.2 1PH82262F2 SLM/BLM 400 V 201 1280 445 305 100 1,500 1,330 454 0.965 19.2 Y connection ALM 400 V 233 1271 440 355 117 1,750 1,330 454 0.965 22.3 SLM/BLM/ALM 480 V 248 1184 410 390 133 2,000 1,330 454 0.965 23.7 SLM/BLM 400 V 228 871 400 360 167 2,500 1,170 532 0.962 21.7 ALM 400 V 238 784 365 413 193 2,900 1,170 532 0.958 22.6 SLM/BLM/ALM 480 V 245 731 340 460 213 3,200 1,170 532 0.954 23.1 1PH82282C2 SLM/BLM 400 V 121 1651 305 270 47 700 1,680 306 0.955 Y connection ALM 400 V 138 1647 305 315 53 800 1,680 306 0.958 13.1 SLM/BLM/ALM 480 V 172 1642 300 390 67 1,000 1,680 306 0.961 16.4 SLM/BLM 400 V 169 1614 395 290 67 1,000 1,680 408 0.962 16.1 ALM 400 V 194 1611 395 330 77 1,150 1,660 408 0.964 18.5 SLM/BLM/ALM 480 V 226 1599 395 395 90 1,350 1,660 408 0.965 21.6 1PH82262L2 Y connection 1PH82282D2 Y connection 2.02 19 11.4 1PH82282F2 SLM/BLM 400 V 251 1598 590 285 100 1,500 1,680 612 0.964 23.9 Y connection ALM 400 V 289 1577 580 335 117 1,750 1,680 612 0.965 27.6 SLM/BLM/ALM 480 V 310 1480 550 380 133 2,000 1,680 612 0.964 29.6 1PH82282L2 SLM/BLM 400 V 270 1031 570 300 167 2,500 1,400 762 0.963 25.7 Y connection ALM 400 V 283 932 520 345 193 2,900 1,400 762 0.958 26.8 SLM/BLM/ALM 480 V 291 868 485 380 213 3,200 1,400 762 0.958 27.5 6.2.1.10 [kg] 810 Overload factors for intermittent duty types (S6) and short-time duty (S2) The specified overload factors for intermittent duty types (S6) and for short-time duty (S2) are based on the S1 characteristic (continuous operation) of the relevant motor. Table 6- 869 S6/S2 overload factors for water-cooled synchronous motors Motor type Overload factors S6 - 60% S6 - 40% S6 - 25% S2 - 30 min 1PH813-22 1.10 1.20 1.50 1.07 1PH816-22 1.10 1.20 1.50 1.07 1PH818-22 1.10 1.20 1.50 1.07 1PH822-22 1.10 1.20 1.50 1.07 1PH8 main motors 1094 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors 6.2.2 Characteristics forced ventilation 6.2.2.1 Shaft height 132 - forced ventilation Table 6- 870 SINAMICS, 3-ph. 400 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8131-F nrated Prated Mrated Irated Popt nopt nmax nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,500 15.7 100 29 17 2,000 4,500 4,500 2,550 220 74 105 30 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1095 Technical data and characteristics 6.2 Synchronous motors Table 6- 871 SINAMICS, 3-ph. 400 V AC, Active Line Module, (ALM), 1PH8131-F nrated Prated Mrated Irated Popt nopt nmax nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 18.0 98 29 19 2,250 4,500 4,500 2,550 220 1,500 15.7 100 29 Imax [A] M0 [Nm] I0 [A] 74 105 30 1PH8 main motors 1096 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 872 SINAMICS, 3-ph. 480 V AC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8131-F nrated Prated Mrated Irated Popt [rpm] [kW] 2,000 19.9 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 95 29 21 2,400 4,500 4,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,550 220 74 105 30 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1097 Technical data and characteristics 6.2 Synchronous motors Table 6- 873 SINAMICS, 3-ph. 400 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8131-L nrated Prated Mrated Irated Popt [rpm] [kW] 2,500 25.0 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 96 44 26 3,050 4,500 4,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,050 220 117 105 48 1PH8 main motors 1098 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 874 SINAMICS, 3-ph. 400 V AC, Active Line Module, (ALM), 1PH8131-L nrated Prated Mrated Irated Popt nopt nmax nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 2,800 27.7 95 44 29 3,400 4,500 4,500 4,050 220 2,500 25.0 96 44 Imax [A] M0 [Nm] I0 [A] 117 105 48 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1099 Technical data and characteristics 6.2 Synchronous motors Table 6- 875 SINAMICS, 3-ph. 480 V AC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8131-L nrated Prated Mrated Irated Popt [rpm] [kW] 3,000 29.5 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 94 43 31 3,600 4,500 4,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 4,050 220 117 105 48 1PH8 main motors 1100 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 876 SINAMICS, 3-ph. 400 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8133-F nrated Prated Mrated Irated Popt [rpm] [kW] 1,500 19.9 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 127 44 26 2,300 4,500 4,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,050 310 124 131 45 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1101 Technical data and characteristics 6.2 Synchronous motors Table 6- 877 SINAMICS, 3-ph. 400 V AC, Active Line Module, (ALM), 1PH8133-F nrated Prated Mrated Irated Popt nopt nmax nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 23.1 126 43 29 2,550 4,500 4,500 3,050 310 1,500 19.9 127 44 Imax [A] M0 [Nm] I0 [A] 124 131 45 1PH8 main motors 1102 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 878 SINAMICS, 3-ph. 480 V AC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8133-F nrated Prated Mrated Irated Popt [rpm] [kW] 2,000 26.2 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 125 43 31 2,750 4,500 4,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,050 310 124 131 45 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1103 Technical data and characteristics 6.2 Synchronous motors Table 6- 879 SINAMICS, 3-ph. 400 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8133-L nrated Prated Mrated Irated Popt [rpm] [kW] 2,500 31.7 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 121 55 33 2,950 4,500 4,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,950 310 162 131 59 1PH8 main motors 1104 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 880 SINAMICS, 3-ph. 400 V AC, Active Line Module, (ALM), 1PH8133-L nrated Prated Mrated Irated Popt nopt nmax nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 2,800 35.2 120 54 37 3,300 4,500 4,500 3,950 310 2,500 31.7 121 55 Imax [A] M0 [Nm] I0 [A] 162 131 59 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1105 Technical data and characteristics 6.2 Synchronous motors Table 6- 881 SINAMICS, 3-ph. 480 V AC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8133-L nrated Prated Mrated Irated Popt [rpm] [kW] 3,000 37.4 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 119 54 39 3,550 4,500 4,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,950 310 162 131 59 1PH8 main motors 1106 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 882 SINAMICS, 3-ph. 400 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8135-F nrated Prated Mrated Irated Popt [rpm] [kW] 1,500 23.7 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 151 43 26 1,900 4,500 4,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,450 390 127 158 44 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1107 Technical data and characteristics 6.2 Synchronous motors Table 6- 883 SINAMICS, 3-ph. 400 V AC, Active Line Module, (ALM), 1PH8135-F nrated Prated Mrated Irated Popt nopt nmax nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 27.2 149 42 29 2,100 4,500 4,500 2,450 390 1,500 23.7 151 43 Imax [A] M0 [Nm] I0 [A] 127 158 44 1PH8 main motors 1108 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 884 SINAMICS, 3-ph. 480 V AC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8135-F nrated Prated Mrated Irated Popt [rpm] [kW] 2,000 30.2 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 144 42 31 2,300 4,500 4,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,450 390 127 158 44 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1109 Technical data and characteristics 6.2 Synchronous motors Table 6- 885 SINAMICS, 3-ph. 400 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8135-G nrated Prated Mrated Irated Popt [rpm] [kW] 2,000 31.4 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 150 59 36 2,650 4,500 4,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,500 390 179 158 63 1PH8 main motors 1110 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 886 SINAMICS, 3-ph. 400 V AC, Active Line Module, (ALM), 1PH8135-G nrated Prated Mrated Irated Popt nopt nmax nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 2,300 35.6 148 59 40 2,950 4,500 4,500 3,500 390 2,000 31.4 150 59 Imax [A] M0 [Nm] I0 [A] 179 158 63 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1111 Technical data and characteristics 6.2 Synchronous motors Table 6- 887 SINAMICS, 3-ph. 480 V AC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8135-G nrated Prated Mrated Irated Popt [rpm] [kW] 2,650 40.2 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 145 58 42 3,150 4,500 4,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,500 390 179 158 63 1PH8 main motors 1112 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 888 SINAMICS, 3-ph. 400 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8137-F nrated Prated Mrated Irated Popt [rpm] [kW] 1,500 30.6 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 195 60 36 2,100 4,500 4,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,700 460 163 203 62 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1113 Technical data and characteristics 6.2 Synchronous motors Table 6- 889 SINAMICS, 3-ph. 400 V AC, Active Line Module, (ALM), 1PH8137-F nrated Prated Mrated Irated Popt nopt nmax nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 35.6 194 59 40 2,300 4,500 4,500 2,700 460 1,500 30.6 195 60 Imax [A] M0 [Nm] I0 [A] 163 203 62 1PH8 main motors 1114 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 890 SINAMICS, 3-ph. 480 V AC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8137-F nrated Prated Mrated Irated Popt [rpm] [kW] 2,000 40.0 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 191 59 43 2,500 4,500 4,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,700 460 163 203 62 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1115 Technical data and characteristics 6.2 Synchronous motors Table 6- 891 SINAMICS, 3-ph. 400 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8137-L nrated Prated Mrated Irated Popt [rpm] [kW] 2,500 48.4 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 185 83 50 2,950 4,500 4,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,900 460 235 203 89 1PH8 main motors 1116 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 892 SINAMICS, 3-ph. 400 V AC, Active Line Module, (ALM), 1PH8137-L nrated Prated Mrated Irated Popt nopt nmax nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 2,800 53.4 182 82 55 3,250 4,500 4,500 3,900 460 2,500 48.4 185 83 Imax [A] M0 [Nm] I0 [A] 235 203 89 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1117 Technical data and characteristics 6.2 Synchronous motors Table 6- 893 SINAMICS, 3-ph. 480 V AC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8137-L nrated Prated Mrated Irated Popt [rpm] [kW] 3,000 56.9 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 181 81 59 3,500 4,500 4,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,900 460 235 203 89 1PH8 main motors 1118 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 894 SINAMICS, 3-ph. 400 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8137-M nrated Prated Mrated Irated Popt [rpm] [kW] 3,000 57.5 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 183 104 62 3,650 4,500 4,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] > 4,500 460 303 203 115 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1119 Technical data and characteristics 6.2 Synchronous motors Table 6- 895 SINAMICS, 3-ph. 400 V AC, Active Line Module, (ALM), 1PH8137-M nrated Prated Mrated Irated Popt nopt nmax nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 3,300 62.2 180 102 68 4,000 4,500 4,500 > 4,500 460 3,000 57.5 183 104 Imax [A] M0 [Nm] I0 [A] 303 203 115 1PH8 main motors 1120 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 896 SINAMICS, 3-ph. 480 V AC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8137-M nrated Prated Mrated Irated Popt [rpm] [kW] 3,600 66.7 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 177 100 72 4,300 4,500 4,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] > 4,500 460 303 203 115 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1121 Technical data and characteristics 6.2 Synchronous motors 6.2.2.2 Shaft height 160 - forced ventilation Table 6- 897 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8165-F nrated Prated Mrated Irated Popt [rpm] [kW] 1,500 61.0 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 390 119 64.4 1,690 4,000 4,000 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,600 1,135 367 440 126 1PH8 main motors 1122 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 898 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8165-F nrated Prated Mrated Irated Popt nopt nmax nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 69.0 375 115 70.1 1,890 4,000 4,000 2,600 1,135 1,500 61.0 390 119 Imax [A] M0 [Nm] I0 [A] 367 440 126 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1123 Technical data and characteristics 6.2 Synchronous motors Table 6- 899 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8165-F nrated Prated Mrated Irated Popt [rpm] [kW] 2,000 74.0 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 355 110 74 2,015 4,000 4,000 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,600 1,135 367 440 126 1PH8 main motors 1124 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 900 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8165-L nrated Prated Mrated Irated Popt [rpm] [kW] 2,500 84.0 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 320 148 84 2,450 4,000 4,000 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,900 1,135 551 440 188 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1125 Technical data and characteristics 6.2 Synchronous motors Table 6- 901 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8165-L nrated Prated Mrated Irated Popt nopt nmax nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 2,800 87.0 300 138 87.8 2,720 4,000 4,000 3,900 1,135 2,500 84.0 320 148 Imax [A] M0 [Nm] I0 [A] 551 440 188 1PH8 main motors 1126 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 902 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8165-L nrated Prated Mrated Irated Popt [rpm] [kW] 3,000 89.0 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 285 131 89.6 2,915 4,000 4,000 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,900 1,135 551 440 188 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1127 Technical data and characteristics 6.2 Synchronous motors Table 6- 903 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8167-F nrated Prated Mrated Irated Popt [rpm] [kW] 1,500 69.0 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 435 133 72.0 1,690 4,000 4,000 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,600 1,280 413 500 143 1PH8 main motors 1128 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 904 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8167-F nrated Prated Mrated Irated Popt nopt nmax nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 77.0 420 128 78.3 1,865 4,000 4,000 2,600 1,280 1,500 69.0 435 133 Imax [A] M0 [Nm] I0 [A] 413 500 143 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1129 Technical data and characteristics 6.2 Synchronous motors Table 6- 905 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8167-F nrated Prated Mrated Irated Popt [rpm] [kW] 2,000 82.0 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 395 123 82.5 2,015 4,000 4,000 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,600 1,280 413 500 143 1PH8 main motors 1130 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 906 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8167-L nrated Prated Mrated Irated Popt [rpm] [kW] 2,500 95.0 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 360 177 95.5 2,580 4,000 4,000 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] >4,000 1,280 661 500 230 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1131 Technical data and characteristics 6.2 Synchronous motors Table 6- 907 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8167-L nrated Prated Mrated Irated Popt nopt nmax nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 2,800 98.0 335 164 98.6 2,880 4,000 4,000 >4,000 1,280 2,500 95.0 360 177 Imax [A] M0 [Nm] I0 [A] 661 500 230 1PH8 main motors 1132 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 908 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8167-L nrated Prated Mrated Irated Popt [rpm] [kW] 3,000 99.0 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 315 155 99.3 3,000 4,000 4,000 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] >4,000 1,280 661 500 230 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1133 Technical data and characteristics 6.2 Synchronous motors 6.2.2.3 Shaft height 180 - forced ventilation Table 6- 909 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8184-2C nrated Prated Mrated Irated Popt nopt nmax nmax, Br [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] 700 33 450 80 37 1,050 3,800 3,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,450 1,450 260 480 84 1PH8 main motors 1134 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 910 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8184-2C nrated Prated Mrated Irated Popt nopt nmax nmax, Br [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] 800 38 454 80 42 1,150 3,800 3,500 700 33 450 80 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,450 1,450 260 480 84 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1135 Technical data and characteristics 6.2 Synchronous motors Table 6- 911 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8184-2C nrated Prated Mrated Irated Popt nopt nmax nmax, Br [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] 1,000 46 439 78 49 1,300 3,800 3,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,450 1,450 260 480 84 1PH8 main motors 1136 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 912 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8184-2D nrated Prated Mrated Irated Popt [rpm] [kW] 1,000 46 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 439 106 50 1,400 3,800 3,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,950 1,450 355 480 115 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1137 Technical data and characteristics 6.2 Synchronous motors Table 6- 913 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8184-2D nrated Prated Mrated Irated Popt nopt nmax nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,150 53 440 106 57 1,550 3,800 3,500 1,950 1,450 1,000 46 439 106 Imax [A] M0 [Nm] I0 [A] 355 480 115 1PH8 main motors 1138 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 914 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8184-2D nrated Prated Mrated Irated Popt [rpm] [kW] 1,350 62 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 439 106 65 1,700 3,800 3,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,950 1,450 355 480 115 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1139 Technical data and characteristics 6.2 Synchronous motors Table 6- 915 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8184-2F nrated Prated Mrated Irated Popt [rpm] [kW] 1,500 70 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 446 148 73 1,900 3,800 3,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,700 1,450 490 480 157 1PH8 main motors 1140 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 916 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8184-2F nrated Prated Mrated Irated Popt nopt nmax nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 82 447 150 84 2,050 3,800 3,500 2,700 1,450 1,500 70 446 148 Imax [A] M0 [Nm] I0 [A] 490 480 157 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1141 Technical data and characteristics 6.2 Synchronous motors Table 6- 917 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8184-2F nrated Prated Mrated Irated Popt [rpm] [kW] 2,000 86 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 411 138 87 2,250 3,800 3,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,700 1,450 490 480 157 1PH8 main motors 1142 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 918 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8186-2C nrated Prated Mrated Irated Popt [rpm] [kW] 700 44 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 600 108 49 1,050 3,800 3,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,450 1,950 358 640 115 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1143 Technical data and characteristics 6.2 Synchronous motors Table 6- 919 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8186-2C nrated Prated Mrated Irated Popt [rpm] [kW] 800 50 700 44 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 597 108 55 1,150 3,800 3,500 600 108 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,450 1,950 358 640 115 1PH8 main motors 1144 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 920 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8186-2C nrated Prated Mrated Irated Popt [rpm] [kW] 1,000 62 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 592 108 65 1,300 3,800 3,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,450 1,950 358 640 115 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1145 Technical data and characteristics 6.2 Synchronous motors Table 6- 921 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8186-2D nrated Prated Mrated Irated Popt [rpm] [kW] 1,000 62 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 592 148 69 1,450 3,800 3,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,050 1,950 490 640 157 1PH8 main motors 1146 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 922 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8186-2D nrated Prated Mrated Irated Popt nopt nmax nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,150 71 590 148 77 1,600 3,800 3,500 2,050 1,950 1,000 62 592 148 Imax [A] M0 [Nm] I0 [A] 490 640 157 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1147 Technical data and characteristics 6.2 Synchronous motors Table 6- 923 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8186-2D nrated Prated Mrated Irated Popt [rpm] [kW] 1,350 83 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 587 146 87 1,750 3,800 3,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,050 1,950 490 640 157 1PH8 main motors 1148 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 924 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8186-2F nrated Prated Mrated Irated Popt [rpm] [kW] 1,500 93 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 592 215 98 1,900 3,800 3,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,950 1,950 720 640 229 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1149 Technical data and characteristics 6.2 Synchronous motors Table 6- 925 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8186-2F nrated Prated Mrated Irated Popt nopt nmax nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 109 595 215 112 2,150 3,800 3,500 2,950 1,950 1,500 93 592 215 Imax [A] M0 [Nm] I0 [A] 720 640 229 1PH8 main motors 1150 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 926 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8186-2F nrated Prated Mrated Irated Popt [rpm] [kW] 2,000 115 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 549 200 117 2,350 3,800 3,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,950 1,950 720 640 229 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1151 Technical data and characteristics 6.2 Synchronous motors 6.2.2.4 Shaft height 225 - forced ventilation Table 6- 927 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8224-2C nrated Prated Mrated Irated Popt nopt [rpm] [kW] 700 48 nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 655 120 52 950 3,500 3,100 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,450 2,400 450 708 128 1PH8 main motors 1152 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 928 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8224-2C nrated Prated Mrated Irated Popt [rpm] [kW] 800 55 700 48 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 657 120 59 1,100 3,500 3,100 655 120 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,450 2,400 450 708 128 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1153 Technical data and characteristics 6.2 Synchronous motors Table 6- 929 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8224-2C nrated Prated Mrated Irated Popt [rpm] [kW] 1,000 68 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 649 118 70 1,250 3,500 3,100 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,450 2,400 450 708 128 1PH8 main motors 1154 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 930 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8224-2D nrated Prated Mrated Irated Popt [rpm] [kW] 1,000 68 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 649 170 73 1,350 3,500 3,100 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,050 2,400 640 708 183 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1155 Technical data and characteristics 6.2 Synchronous motors Table 6- 931 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8224-2D nrated Prated Mrated Irated Popt nopt nmax nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,150 78 648 170 83 1,550 3,500 3,100 2,050 2,400 1,000 68 649 170 Imax [A] M0 [Nm] I0 [A] 640 708 183 1PH8 main motors 1156 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 932 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8224-2D nrated Prated Mrated Irated Popt [rpm] [kW] 1,350 91 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 643 168 94 1,700 3,500 3,100 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,050 2,400 640 708 183 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1157 Technical data and characteristics 6.2 Synchronous motors Table 6- 933 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8224-2F nrated Prated Mrated Irated Popt [rpm] [kW] 1,500 101 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 643 235 105 1,850 3,500 3,100 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,900 2,400 900 708 256 1PH8 main motors 1158 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 934 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8224-2F nrated Prated Mrated Irated Popt nopt nmax nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 117 638 235 120 2,050 3,500 3,100 2,900 2,400 1,500 101 643 235 Imax [A] M0 [Nm] I0 [A] 900 708 256 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1159 Technical data and characteristics 6.2 Synchronous motors Table 6- 935 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8224-2F nrated Prated Mrated Irated Popt [rpm] [kW] 2,000 118 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 563 210 119 2,250 3,500 3,100 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,900 2,400 900 708 256 1PH8 main motors 1160 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 936 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8226-2C nrated Prated Mrated Irated Popt [rpm] [kW] 700 64 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 873 170 70 1,000 3,500 3,100 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,550 3,200 640 944 183 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1161 Technical data and characteristics 6.2 Synchronous motors Table 6- 937 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8226-2C nrated Prated Mrated Irated Popt [rpm] [kW] 800 73 700 64 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 872 170 80 1,100 3,500 3,100 873 170 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,550 3,200 640 944 183 1PH8 main motors 1162 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 938 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8226-2C nrated Prated Mrated Irated Popt [rpm] [kW] 1,000 91 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 869 170 95 1,300 3,500 3,100 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,550 3,200 640 944 183 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1163 Technical data and characteristics 6.2 Synchronous motors Table 6- 939 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8226-2D nrated Prated Mrated Irated Popt [rpm] [kW] 1,000 91 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 869 215 97 1,350 3,500 3,100 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,950 3,200 820 944 233 1PH8 main motors 1164 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 940 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8226-2D nrated Prated Mrated Irated Popt nopt nmax nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,150 104 863 215 109 1,500 3,500 3,100 1,950 3,200 1,000 91 869 215 Imax [A] M0 [Nm] I0 [A] 820 944 233 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1165 Technical data and characteristics 6.2 Synchronous motors Table 6- 941 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8226-2D nrated Prated Mrated Irated Popt [rpm] [kW] 1,350 121 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 855 215 124 1,650 3,500 3,100 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,950 3,200 820 944 233 1PH8 main motors 1166 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 942 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8226-2F nrated Prated Mrated Irated Popt [rpm] [kW] 1,500 134 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 853 295 138 1,800 3,500 3,100 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,700 3,200 1,120 944 320 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1167 Technical data and characteristics 6.2 Synchronous motors Table 6- 943 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8226-2F nrated Prated Mrated Irated Popt nopt nmax nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 156 851 295 158 2,000 3,500 3,100 2,700 3,200 1,500 134 853 295 Imax [A] M0 [Nm] I0 [A] 1,120 944 320 1PH8 main motors 1168 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 944 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8226-2F nrated Prated Mrated Irated Popt [rpm] [kW] 2,000 157 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 750 260 158 2,200 3,500 3,100 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,700 3,200 1,120 944 320 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1169 Technical data and characteristics 6.2 Synchronous motors Table 6- 945 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8228-2C nrated Prated [rpm] [kW] 700 80 Mrated Irated Popt nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 1,092 200 86 950 3,500 3,100 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,450 4,000 750 1,180 213 1PH8 main motors 1170 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 946 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8228-2C nrated Prated Mrated Irated Popt [rpm] [kW] 800 91 700 80 1,092 200 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 1,086 198 96 1,050 3,500 3,100 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,450 4,000 750 1,180 213 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1171 Technical data and characteristics 6.2 Synchronous motors Table 6- 947 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8228-2C nrated Prated [rpm] [kW] 1,000 113 Mrated Irated Popt nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 1,079 198 116 1,200 3,500 3,100 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,450 4,000 750 1,180 213 1PH8 main motors 1172 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 948 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8228-2D nrated Prated [rpm] [kW] 1,000 113 Mrated Irated Popt nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 1,079 265 119 1,300 3,500 3,100 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,950 4,000 1,000 1,180 284 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1173 Technical data and characteristics 6.2 Synchronous motors Table 6- 949 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8228-2D nrated Prated Mrated Irated Popt nopt nmax nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,150 129 1,071 260 135 1,450 3,500 3,100 1,950 4,000 1,000 113 1,079 265 Imax [A] M0 [Nm] I0 [A] 1,000 1,180 284 1PH8 main motors 1174 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 950 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8228-2D nrated Prated [rpm] [kW] 1,350 151 Mrated Irated Popt nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 1,068 260 155 1,600 3,500 3,100 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,950 4,000 1,000 1,180 284 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1175 Technical data and characteristics 6.2 Synchronous motors Table 6- 951 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8228-2F nrated Prated [rpm] [kW] 1,500 168 Mrated Irated Popt nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 1,070 395 174 1,850 3,500 3,100 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,900 4,000 1,500 1,180 427 1PH8 main motors 1176 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 952 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8228-2F nrated Prated Mrated Irated Popt nopt nmax nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 195 1,064 390 199 2,050 3,500 3,100 2,900 4,000 1,500 168 1,070 395 Imax [A] M0 [Nm] I0 [A] 1,500 1,180 427 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1177 Technical data and characteristics 6.2 Synchronous motors Table 6- 953 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8228-2F nrated Prated Mrated Irated Popt [rpm] [kW] 2,000 196 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 936 345 198 2,200 3,500 3,100 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,900 4,000 1,500 1,180 427 1PH8 main motors 1178 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors 6.2.3 Characteristics water cooling 6.2.3.1 Shaft height 132 - water-cooled Table 6- 954 SINAMICS, 3-ph. 400 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8131-F2 nrated Prated Mrated Irated Popt nopt nmax nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,500 17.6 112 40 23 2,500 4,500 4,500 3,150 220 90 115 41 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1179 Technical data and characteristics 6.2 Synchronous motors Table 6- 955 SINAMICS, 3-ph. 400 V AC, Active Line Module, (ALM), 1PH8131-F2 nrated Prated Mrated Irated Popt nopt nmax nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 20.4 112 40 26 2,750 4,500 4,500 3,150 220 1,500 17.6 112 40 Imax [A] M0 [Nm] I0 [A] 90 115 41 1PH8 main motors 1180 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 956 SINAMICS, 3-ph. 480 V AC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8131-F2 nrated Prated Mrated Irated Popt [rpm] [kW] 2,000 23.2 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 111 39 28 2,950 4,500 4,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,150 220 90 115 41 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1181 Technical data and characteristics 6.2 Synchronous motors Table 6- 957 SINAMICS, 3-ph. 400 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8131-L2 nrated Prated Mrated Irated Popt [rpm] [kW] 2,500 28.5 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 109 57 34 3,550 4,500 4,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] > 4,500 220 133 115 60 1PH8 main motors 1182 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 958 SINAMICS, 3-ph. 400 V AC, Active Line Module, (ALM), 1PH8131-L2 nrated Prated Mrated Irated Popt nopt nmax nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 2,800 31.7 108 56 37 3,900 4,500 4,500 > 4,500 220 2,500 28.5 109 57 Imax [A] M0 [Nm] I0 [A] 133 115 60 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1183 Technical data and characteristics 6.2 Synchronous motors Table 6- 959 SINAMICS, 3-ph. 480 V AC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8131-L2 nrated Prated Mrated Irated Popt [rpm] [kW] 3,000 33.6 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 107 56 39 4,150 4,500 4,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] > 4,500 220 133 115 60 1PH8 main motors 1184 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 960 SINAMICS, 3-ph. 400 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8133-F2 nrated Prated Mrated Irated Popt [rpm] [kW] 1,500 23.1 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 147 42 25 2,000 4,500 4,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,450 310 100 155 43 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1185 Technical data and characteristics 6.2 Synchronous motors Table 6- 961 SINAMICS, 3-ph. 400 V AC, Active Line Module, (ALM), 1PH8133-F2 nrated Prated Mrated Irated Popt nopt nmax nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 26.4 144 42 28 2,250 4,500 4,500 2,450 310 1,500 23.1 147 42 Imax [A] M0 [Nm] I0 [A] 100 155 43 1PH8 main motors 1186 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 962 SINAMICS, 3-ph. 480 V AC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8133-F2 nrated Prated Mrated Irated Popt [rpm] [kW] 2,000 29.0 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 139 41 30 2,400 4,500 4,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,450 310 100 155 43 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1187 Technical data and characteristics 6.2 Synchronous motors Table 6- 963 SINAMICS, 3-ph. 400 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8133-G2 nrated Prated Mrated Irated Popt [rpm] [kW] 2,000 30.6 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 146 57 34 2,750 4,500 4,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,450 310 140 155 61 1PH8 main motors 1188 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 964 SINAMICS, 3-ph. 400 V AC, Active Line Module, (ALM), 1PH8133-G2 nrated Prated Mrated Irated Popt nopt nmax nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 2,300 34.9 145 57 38 3,050 4,500 4,500 3,450 310 2,000 30.6 146 57 Imax [A] M0 [Nm] I0 [A] 140 155 61 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1189 Technical data and characteristics 6.2 Synchronous motors Table 6- 965 SINAMICS, 3-ph. 480 V AC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8133-G2 nrated Prated Mrated Irated Popt [rpm] [kW] 2,650 39.1 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 141 57 41 3,250 4,500 4,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,450 310 140 155 61 1PH8 main motors 1190 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 966 SINAMICS, 3-ph. 400 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8135-F2 nrated Prated Mrated Irated Popt [rpm] [kW] 1,500 29.7 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 189 57 34 2,150 4,500 4,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,650 390 135 196 59 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1191 Technical data and characteristics 6.2 Synchronous motors Table 6- 967 SINAMICS, 3-ph. 400 V AC, Active Line Module, (ALM), 1PH8135-F2 nrated Prated Mrated Irated Popt nopt nmax nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 34.1 186 56 37 2,400 4,500 4,500 2,650 390 1,500 29.7 189 57 Imax [A] M0 [Nm] I0 [A] 135 196 59 1PH8 main motors 1192 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 968 SINAMICS, 3-ph. 480 V AC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8135-F2 nrated Prated Mrated Irated Popt [rpm] [kW] 2,000 37.9 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 181 56 40 2,550 4,500 4,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,650 390 135 196 59 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1193 Technical data and characteristics 6.2 Synchronous motors Table 6- 969 SINAMICS, 3-ph. 400 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8135-G2 nrated Prated Mrated Irated Popt [rpm] [kW] 2,000 39.0 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 186 81 48 3,000 4,500 4,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,800 390 196 196 85 1PH8 main motors 1194 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 970 SINAMICS, 3-ph. 400 V AC, Active Line Module, (ALM), 1PH8135-G2 nrated Prated Mrated Irated Popt nopt nmax nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 2,300 44.3 184 80 53 3,300 4,500 4,500 3,800 390 2,000 39.0 186 81 Imax [A] M0 [Nm] I0 [A] 196 196 85 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1195 Technical data and characteristics 6.2 Synchronous motors Table 6- 971 SINAMICS, 3-ph. 480 V AC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8135-G2 nrated Prated Mrated Irated Popt [rpm] [kW] 2,650 50.5 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 182 79 56 3,550 4,500 4,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,800 390 196 196 85 1PH8 main motors 1196 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 972 SINAMICS, 3-ph. 400 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8137-F2 nrated Prated Mrated Irated Popt [rpm] [kW] 1,500 32.7 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 208 58 35 1,950 4,500 4,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,350 460 141 226 60 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1197 Technical data and characteristics 6.2 Synchronous motors Table 6- 973 SINAMICS, 3-ph. 400 V AC, Active Line Module, (ALM), 1PH8137-F2 nrated Prated Mrated Irated Popt nopt nmax nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 37.0 202 58 38 2,150 4,500 4,500 2,350 460 1,500 34.1 217 58 Imax [A] M0 [Nm] I0 [A] 141 226 60 1PH8 main motors 1198 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 974 SINAMICS, 3-ph. 480 V AC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8137-F2 nrated Prated Mrated Irated Popt [rpm] [kW] 2,000 40.6 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 194 57 41 2,350 4,500 4,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,350 460 141 226 60 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1199 Technical data and characteristics 6.2 Synchronous motors Table 6- 975 SINAMICS, 3-ph. 400 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8137-G2 nrated Prated Mrated Irated Popt [rpm] [kW] 2,000 44.4 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 212 85 50 2,800 4,500 4,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,500 460 212 226 90 1PH8 main motors 1200 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 976 SINAMICS, 3-ph. 400 V AC, Active Line Module, (ALM), 1PH8137-G2 nrated Prated Mrated Irated Popt nopt nmax nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 2,300 50.5 210 84 56 3,100 4,500 4,500 3,500 460 2,000 44.4 212 85 Imax [A] M0 [Nm] I0 [A] 212 226 90 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1201 Technical data and characteristics 6.2 Synchronous motors Table 6- 977 SINAMICS, 3-ph. 480 V AC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8137-G2 nrated Prated Mrated Irated Popt [rpm] [kW] 2,650 56.8 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 205 83 60 3,300 4,500 4,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,500 460 212 226 90 1PH8 main motors 1202 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 978 SINAMICS, 3-ph. 400 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8138-F2 nrated Prated Mrated Irated Popt [rpm] [kW] 1,500 44.9 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 286 118 68 4,200 4,500 4,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,500 460 212 290 120 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1203 Technical data and characteristics 6.2 Synchronous motors Table 6- 979 SINAMICS, 3-ph. 400 V AC, Active Line Module, (ALM), 1PH8138-F2 nrated Prated Mrated Irated Popt nopt nmax nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 52.4 286 118 76 4,500 4,500 4,500 3,500 460 1,500 44.9 286 118 Imax [A] M0 [Nm] I0 [A] 212 290 120 1PH8 main motors 1204 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 980 SINAMICS, 3-ph. 480 V AC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8138-F2 nrated Prated Mrated Irated Popt [rpm] [kW] 2,000 59.7 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 285 118 82 4,500 4,500 4,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,500 460 212 290 120 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1205 Technical data and characteristics 6.2 Synchronous motors Table 6- 981 SINAMICS, 3-ph. 400 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8138-G2 nrated Prated Mrated Irated Popt [rpm] [kW] 2,000 59.3 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 283 131 76 4,500 4,500 4,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,900 460 235 290 133 1PH8 main motors 1206 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 982 SINAMICS, 3-ph. 400 V AC, Active Line Module, (ALM), 1PH8138-G2 nrated Prated Mrated Irated Popt nopt nmax nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 2,300 67.7 281 130 84 4,500 4,500 4,500 3,900 460 2,000 59.7 285 131 Imax [A] M0 [Nm] I0 [A] 235 290 133 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1207 Technical data and characteristics 6.2 Synchronous motors Table 6- 983 SINAMICS, 3-ph. 480 V AC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8138-G2 nrated Prated Mrated Irated Popt [rpm] [kW] 2,650 76.3 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 275 130 91 4,500 4,500 4,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,900 460 235 290 133 1PH8 main motors 1208 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors 6.2.3.2 Shaft height 160 - water cooling Table 6- 984 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8164-2F2 nrated Prated Mrated Irated Popt [rpm] [kW] 1,500 59.0 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 375 111 59.5 1,615 4,000 4,000 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,400 915 276 440 118 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1209 Technical data and characteristics 6.2 Synchronous motors Table 6- 985 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8164-2F2 nrated Prated Mrated Irated Popt nopt nmax nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 67.0 365 108 67 1,790 4,000 4,000 2,400 915 1,500 59.0 375 111 Imax [A] M0 [Nm] I0 [A] 276 440 118 1PH8 main motors 1210 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 986 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8164-2F2 nrated Prated Mrated Irated Popt [rpm] [kW] 2,000 70.0 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 330 105 70 1,940 4,000 4,000 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,400 915 276 440 118 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1211 Technical data and characteristics 6.2 Synchronous motors Table 6- 987 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8164-2L2 nrated Prated Mrated Irated Popt [rpm] [kW] 2,500 88.0 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 335 165 88.7 2,615 4,000 4,000 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] >4,000 915 472 440 205 1PH8 main motors 1212 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 988 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8164-2L2 nrated Prated Mrated Irated Popt nopt nmax nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 2,800 93.0 315 156 93.5 2,885 4,000 4,000 >4,000 915 2,500 88.0 335 165 Imax [A] M0 [Nm] I0 [A] 472 440 205 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1213 Technical data and characteristics 6.2 Synchronous motors Table 6- 989 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8164-2L2 nrated Prated Mrated Irated Popt [rpm] [kW] 3,000 96.0 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 305 150 96 3,065 4,000 4,000 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] >4,000 915 472 440 205 1PH8 main motors 1214 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 990 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8166-2F2 nrated Prated Mrated Irated Popt [rpm] [kW] 1,500 74.0 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 475 148 77.8 1,715 4,000 4,000 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,600 1,135 367 550 159 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1215 Technical data and characteristics 6.2 Synchronous motors Table 6- 991 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8166-2F2 nrated Prated Mrated Irated Popt nopt nmax nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 85.0 460 143 85 1,915 4,000 4,000 2,600 1,135 1,500 74.0 475 148 Imax [A] M0 [Nm] I0 [A] 367 550 159 1PH8 main motors 1216 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 992 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8166-2F2 nrated Prated Mrated Irated Popt [rpm] [kW] 2,000 89.0 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 425 138 89.5 2,040 4,000 4,000 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,600 1,135 367 550 159 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1217 Technical data and characteristics 6.2 Synchronous motors Table 6- 993 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8166-2L2 nrated Prated Mrated Irated Popt nopt nmax nmax, Br [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] 2,500 102.0 390 188 102.0 2,450 4,000 4,000 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,900 1,135 551 550 240 1PH8 main motors 1218 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 994 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8166-2L2 nrated Prated Mrated Irated Popt nopt nmax nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 2,800 109.0 375 177 109 2,720 4,000 4,000 3,900 1,135 2,500 102.0 390 188 Imax [A] M0 [Nm] I0 [A] 551 550 240 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1219 Technical data and characteristics 6.2 Synchronous motors Table 6- 995 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8166-2L2 nrated Prated Mrated Irated Popt nopt nmax nmax, Br [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] 3,000 110.0 350 169 110.4 2,900 4,000 4,000 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 3,900 1,135 551 550 240 1PH8 main motors 1220 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 996 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8168-2F2 nrated Prated Mrated Irated Popt [rpm] [kW] 1,500 84.0 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 530 169 87.4 1,715 4,000 4,000 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,600 1,280 413 620 179 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1221 Technical data and characteristics 6.2 Synchronous motors Table 6- 997 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8168-2F2 nrated Prated Mrated Irated Popt nopt nmax nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 94.0 510 164 95.1 1,890 4,000 4,000 2,600 1,280 1,500 84.0 530 169 Imax [A] M0 [Nm] I0 [A] 413 620 179 1PH8 main motors 1222 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 998 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8168-2F2 nrated Prated Mrated Irated Popt nopt nmax nmax, Br [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] 2,000 100.0 480 157 100.2 2,015 4,000 4,000 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,600 1,280 413 620 179 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1223 Technical data and characteristics 6.2 Synchronous motors Table 6- 999 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8168-2L2 nrated Prated Mrated Irated Popt nopt nmax nmax, Br [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] 2,500 118.0 450 225 118.1 2,570 4,000 4,000 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] >4,000 1,280 661 520 240 1PH8 main motors 1224 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 1000 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8168-2L2 nrated Prated Mrated Irated Popt nopt nmax nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 2,800 123.0 420 210 123.5 2,840 4,000 4,000 >4,000 1,280 2,500 118.0 450 225 Imax [A] M0 [Nm] I0 [A] 661 520 240 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1225 Technical data and characteristics 6.2 Synchronous motors Table 6- 1001 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8168-2L2 nrated Prated Mrated Irated Popt [rpm] [kW] 3,000 125.0 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 395 197 125 3,020 4,000 4,000 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] >4,000 1,280 661 520 240 1PH8 main motors 1226 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors 6.2.3.3 Shaft height 180 - water-cooled Table 6- 1002 SINAMICS, 3-ph. 400 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8184-2C2 nrated Prated Mrated Irated Popt [rpm] [kW] 700 42 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 573 100 61 1,150 3,800 3,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,450 1,450 260 590 103 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1227 Technical data and characteristics 6.2 Synchronous motors Table 6- 1003 SINAMICS, 3-ph. 400 V AC, Active Line Module, (ALM), 1PH8184-2C2 nrated Prated Mrated Irated Popt [rpm] [kW] 800 48 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 573 102 68 1,250 3,800 3,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,450 1,450 260 590 103 1PH8 main motors 1228 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 1004 SINAMICS, 3-ph. 480 V AC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8184-2C2 nrated Prated Mrated Irated Popt [rpm] [kW] 1,000 60 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 573 102 74 1,400 3,800 3,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,450 1,450 260 590 103 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1229 Technical data and characteristics 6.2 Synchronous motors Table 6- 1005 SINAMICS, 3-ph. 400 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8184-2D2 nrated Prated Mrated Irated Popt [rpm] [kW] 1,000 61 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 583 140 84 1,500 3,800 3,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,950 1,450 355 600 143 1PH8 main motors 1230 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 1006 SINAMICS, 3-ph. 400 V AC, Active Line Module, (ALM), 1PH8184-2D2 nrated Prated Mrated Irated Popt [rpm] [kW] 1,150 70 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 581 140 94 1,700 3,800 3,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,950 1,450 355 600 143 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1231 Technical data and characteristics 6.2 Synchronous motors Table 6- 1007 SINAMICS, 3-ph. 480 V AC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8184-2D2 nrated Prated Mrated Irated Popt [rpm] [kW] 1,350 82 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 580 140 100 1,800 3,800 3,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,950 1,450 355 600 143 1PH8 main motors 1232 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 1008 SINAMICS, 3-ph. 400 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8184-2F2 nrated Prated Mrated Irated Popt [rpm] [kW] 1,500 90 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 573 190 111 2,000 3,800 3,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,700 1,450 490 600 196 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1233 Technical data and characteristics 6.2 Synchronous motors Table 6- 1009 SINAMICS, 3-ph. 400 V AC, Active Line Module, (ALM), 1PH8184-2F2 nrated Prated Mrated Irated Popt [rpm] [kW] 1,750 103 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 562 186 120 2,150 3,800 3,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,700 1,450 490 600 196 1PH8 main motors 1234 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 1010 SINAMICS, 3-ph. 480 V AC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8184-2F2 nrated Prated Mrated Irated Popt [rpm] [kW] 2,000 110 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 525 176 125 2,250 3,800 3,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,700 1,450 490 600 196 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1235 Technical data and characteristics 6.2 Synchronous motors Table 6- 1011 SINAMICS, 3-ph. 400 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8184-2L2 nrated Prated Mrated Irated Popt [rpm] [kW] 2,500 127 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 485 260 127 3,800 3,800 3,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] >3,800 1,450 780 530 278 1PH8 main motors 1236 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 1012 SINAMICS, 3-ph. 400 V AC, Active Line Module, (ALM), 1PH8184-2L2 nrated Prated Mrated Irated Popt [rpm] [kW] 2,900 140 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 461 250 140 3,800 3,800 3,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] >3,800 1,450 780 530 278 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1237 Technical data and characteristics 6.2 Synchronous motors Table 6- 1013 SINAMICS, 3-ph. 480 V AC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8184-2L2 nrated Prated Mrated Irated Popt [rpm] [kW] 3,200 142 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 424 230 142 3,800 3,800 3,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] >3,800 1,450 780 530 278 1PH8 main motors 1238 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 1014 SINAMICS, 3-ph. 400 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8186-2C2 nrated Prated Mrated Irated Popt [rpm] [kW] 700 58 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 791 142 84 1,150 3,800 3,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,450 1,950 358 800 143 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1239 Technical data and characteristics 6.2 Synchronous motors Table 6- 1015 SINAMICS, 3-ph. 400 V AC, Servo Control, (Active Line Module), 1PH8186-2C2 nrated Prated Mrated Irated Popt [rpm] [kW] 800 66 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 788 142 95 1,250 3,800 3,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,450 1,950 358 800 143 1PH8 main motors 1240 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 1016 SINAMICS, 3-ph. 480 V AC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8186-2C2 nrated Prated Mrated Irated Popt [rpm] [kW] 1,000 82 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 783 141 102 1,400 3,800 3,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,450 1,950 358 800 143 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1241 Technical data and characteristics 6.2 Synchronous motors Table 6- 1017 SINAMICS, 3-ph. 400 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8186-2D2 nrated Prated Mrated Irated Popt [rpm] [kW] 1,000 80 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 764 190 114 1,550 3,800 3,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,050 1,950 490 800 196 1PH8 main motors 1242 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 1018 SINAMICS, 3-ph. 400 V AC, Servo Control, (Active Line Module), 1PH8186-2D2 nrated Prated Mrated Irated Popt [rpm] [kW] 1,150 92 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 764 190 128 1,700 3,800 3,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,050 1,950 490 800 196 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1243 Technical data and characteristics 6.2 Synchronous motors Table 6- 1019 SINAMICS, 3-ph. 480 V AC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8186-2D2 nrated Prated Mrated Irated Popt [rpm] [kW] 1,350 107 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 757 190 136 1,850 3,800 3,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,050 1,950 490 800 196 1PH8 main motors 1244 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 1020 SINAMICS, 3-ph. 400 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8186-2F2 nrated Prated Mrated Irated Popt [rpm] [kW] 1,500 119 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 758 275 155 2,150 3,800 3,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,950 1,950 720 800 285 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1245 Technical data and characteristics 6.2 Synchronous motors Table 6- 1021 SINAMICS, 3-ph. 400 V AC, Servo Control, (Active Line Module), 1PH8186-2F2 nrated Prated Mrated Irated Popt [rpm] [kW] 1,750 138 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 753 275 165 2,400 3,800 3,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,950 1,950 720 800 285 1PH8 main motors 1246 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 1022 SINAMICS, 3-ph. 480 V AC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8186-2F2 nrated Prated Mrated Irated Popt [rpm] [kW] 2,000 154 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 735 265 172 2,550 3,800 3,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,950 1,950 720 800 285 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1247 Technical data and characteristics 6.2 Synchronous motors Table 6- 1023 SINAMICS, 3-ph. 400 V AC, Smart/Basic Line Module, (SLM/BLM), 1PH8186-2L2 nrated Prated Mrated Irated Popt [rpm] [kW] 2,500 168 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 642 370 168 3,800 3,800 3,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] >3,800 1,950 1,125 720 405 1PH8 main motors 1248 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 1024 SINAMICS, 3-ph. 400 V AC, Servo Control, (Active Line Module), 1PH8186-2L2 nrated Prated Mrated Irated Popt [rpm] [kW] 2,900 178 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 586 340 178 3,800 3,800 3,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] >3,800 1,950 1,125 720 405 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1249 Technical data and characteristics 6.2 Synchronous motors Table 6- 1025 SINAMICS, 3-ph. 480 V AC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8186-2L2 nrated Prated Mrated Irated Popt [rpm] [kW] 3,200 183 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 546 315 183 3,800 3,800 3,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] >3,800 1,950 1,125 720 405 1PH8 main motors 1250 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors 6.2.3.4 Shaft height 225 - water-cooled Table 6- 1026 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8224-2C2 nrated Prated Mrated Irated Popt [rpm] [kW] 700 72 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 982 180 84 1,150 3,500 3,500 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,450 2,400 450 1,007 183 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1251 Technical data and characteristics 6.2 Synchronous motors Table 6- 1027 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8224-2C2 nrated Prated Mrated Irated Popt [rpm] [kW] 800 81 700 72 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 967 178 91 1,200 3,500 3,100 982 180 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,450 2,400 450 1,007 183 1PH8 main motors 1252 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 1028 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8224-2C2 nrated Prated Mrated Irated Popt [rpm] [kW] 1,000 101 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 964 178 107 1,300 3,500 3,100 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,450 2,400 450 1,007 183 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1253 Technical data and characteristics 6.2 Synchronous motors Table 6- 1029 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8224-2D2 nrated Prated Mrated Irated Popt [rpm] [kW] 1,000 101 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 964 255 111 1,400 3,500 3,100 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,050 2,400 640 1,007 262 1PH8 main motors 1254 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 1030 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8224-2D2 nrated Prated Mrated Irated Popt nopt nmax nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,150 115 955 250 123 1,550 3,500 3,100 2,050 2,400 1,000 101 964 255 Imax [A] M0 [Nm] I0 [A] 640 1,007 262 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1255 Technical data and characteristics 6.2 Synchronous motors Table 6- 1031 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8224-2D2 nrated Prated Mrated Irated Popt [rpm] [kW] 1,350 135 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 955 250 140 1,700 3,500 3,100 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,050 2,400 640 1,007 262 1PH8 main motors 1256 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 1032 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8224-2F2 nrated Prated Mrated Irated Popt [rpm] [kW] 1,500 151 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 961 355 159 1,950 3,500 3,100 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,900 2,400 900 1,007 367 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1257 Technical data and characteristics 6.2 Synchronous motors Table 6- 1033 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8224-2F2 nrated Prated Mrated Irated Popt nopt nmax nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 175 955 355 181 2,150 3,500 3,100 2,900 2,400 1,500 151 961 355 Imax [A] M0 [Nm] I0 [A] 900 1,007 367 1PH8 main motors 1258 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 1034 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8224-2F2 nrated Prated Mrated Irated Popt [rpm] [kW] 2,000 186 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 888 330 190 2,350 3,500 3,100 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,900 2,400 900 1,007 367 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1259 Technical data and characteristics 6.2 Synchronous motors Table 6- 1035 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8224-2L2 nrated Prated Mrated Irated Popt [rpm] [kW] 2,500 182 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 695 365 187 3,000 3,500 3,100 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] >3,500 2,400 1,280 885 460 1PH8 main motors 1260 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 1036 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8224-2L2 nrated Prated Mrated Irated Popt nopt nmax nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 2,900 191 629 335 193 3,200 3,500 3,100 >3,500 2,400 2,500 182 695 365 Imax [A] M0 [Nm] I0 [A] 1,280 885 460 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1261 Technical data and characteristics 6.2 Synchronous motors Table 6- 1037 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8224-2L2 nrated Prated Mrated Irated Popt [rpm] [kW] 3,200 196 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 585 310 196 3,350 3,500 3,100 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] >3,500 2,400 1,280 885 460 1PH8 main motors 1262 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 1038 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8226-2C2 nrated Prated [rpm] [kW] 700 95 Mrated Irated Popt nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 1,296 255 114 1,200 3,500 3,100 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,550 3,200 640 1,330 260 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1263 Technical data and characteristics 6.2 Synchronous motors Table 6- 1039 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8226-2C2 nrated Prated Mrated Irated Popt [rpm] [kW] 800 108 700 95 1,296 255 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 1,289 255 125 1,250 3,500 3,100 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,550 3,200 640 1,330 260 1PH8 main motors 1264 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 1040 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8226-2C2 nrated Prated [rpm] [kW] 1,000 134 Mrated Irated Popt nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 1,280 255 145 1,400 3,500 3,100 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,550 3,200 640 1,330 260 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1265 Technical data and characteristics 6.2 Synchronous motors Table 6- 1041 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8226-2D2 nrated Prated [rpm] [kW] 1,000 135 Mrated Irated Popt nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 1,289 325 148 1,450 3,500 3,100 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,950 3,200 820 1,330 330 1PH8 main motors 1266 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 1042 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8226-2D2 nrated Prated Mrated Irated Popt nopt nmax nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,150 155 1,287 325 165 1,550 3,500 3,100 1,950 3,200 1,000 135 1,289 325 Imax [A] M0 [Nm] I0 [A] 820 1,330 330 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1267 Technical data and characteristics 6.2 Synchronous motors Table 6- 1043 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8226-2D2 nrated Prated [rpm] [kW] 1,350 180 Mrated Irated Popt nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 1,273 320 187 1,650 3,500 3,100 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,950 3,200 820 1,330 330 1PH8 main motors 1268 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 1044 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8226-2F2 nrated Prated [rpm] [kW] 1,500 201 Mrated Irated Popt nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 1,280 445 209 1,850 3,500 3,100 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,700 3,200 1,120 1,330 454 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1269 Technical data and characteristics 6.2 Synchronous motors Table 6- 1045 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8226-2F2 nrated Prated Mrated Irated Popt nopt nmax nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 233 1,271 440 239 2,100 3,500 3,100 2,700 3,200 1,500 201 1,280 445 Imax [A] M0 [Nm] I0 [A] 1,120 1,330 454 1PH8 main motors 1270 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 1046 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8226-2F2 nrated Prated [rpm] [kW] 2,000 248 Mrated Irated Popt nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 1,184 410 252 2,300 3,500 3,100 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,700 3,200 1,120 1,330 454 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1271 Technical data and characteristics 6.2 Synchronous motors Table 6- 1047 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8226-2L2 nrated Prated Mrated Irated Popt [rpm] [kW] 2,500 228 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 871 400 235 3,000 3,500 3,100 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] >3,500 3,200 1,500 1,170 532 1PH8 main motors 1272 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 1048 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8226-2L2 nrated Prated Mrated Irated Popt nopt nmax nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 2,900 238 784 365 240 3,200 3,500 3,100 >3,500 3,200 2,500 228 871 400 Imax [A] M0 [Nm] I0 [A] 1,500 1,170 532 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1273 Technical data and characteristics 6.2 Synchronous motors Table 6- 1049 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8226-2L2 nrated Prated Mrated Irated Popt [rpm] [kW] 3,200 245 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 731 340 245 3,350 3,500 3,100 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] >3,500 3,200 1,500 1,170 532 1PH8 main motors 1274 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 1050 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8228-2C2 nrated Prated [rpm] [kW] 700 121 Mrated Irated Popt nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 1,651 305 141 1,150 3,500 3,100 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,450 4,000 750 1,680 306 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1275 Technical data and characteristics 6.2 Synchronous motors Table 6- 1051 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8228-2C2 nrated Prated Mrated Irated Popt [rpm] [kW] 800 138 700 121 1,651 305 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 1,647 305 157 1,250 3,500 3,100 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,450 4,000 750 1,680 306 1PH8 main motors 1276 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 1052 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8228-2C2 nrated Prated [rpm] [kW] 1,000 172 Mrated Irated Popt nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 1,642 300 184 1,350 3,500 3,100 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,450 4,000 750 1,680 306 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1277 Technical data and characteristics 6.2 Synchronous motors Table 6- 1053 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8228-2D2 nrated Prated [rpm] [kW] 1,000 169 Mrated Irated Popt nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 1,614 395 184 1,400 3,500 3,100 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,950 4,000 1,000 1,680 408 1PH8 main motors 1278 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 1054 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8228-2D2 nrated Prated Mrated Irated Popt nopt nmax nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,150 194 1,611 395 205 1,500 3,500 3,100 1,950 4,000 1,000 169 1,614 395 Imax [A] M0 [Nm] I0 [A] 1,000 1,680 408 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1279 Technical data and characteristics 6.2 Synchronous motors Table 6- 1055 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8228-2D2 nrated Prated [rpm] [kW] 1,350 226 Mrated Irated Popt nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 1,599 395 235 1,700 3,500 3,100 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 1,950 4,000 1,000 1,680 408 1PH8 main motors 1280 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 1056 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8228-2F2 nrated Prated [rpm] [kW] 1,500 251 Mrated Irated Popt nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 1,598 590 264 1,900 3,500 3,100 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,900 4,000 1,500 1,680 612 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1281 Technical data and characteristics 6.2 Synchronous motors Table 6- 1057 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8228-2F2 nrated Prated Mrated Irated Popt nopt nmax nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 1,750 289 1,577 580 299 2,150 3,500 3,100 2,900 4,000 1,500 251 1,598 590 Imax [A] M0 [Nm] I0 [A] 1,500 1,680 612 1PH8 main motors 1282 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 1058 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8228-2F2 nrated Prated [rpm] [kW] 2,000 310 Mrated Irated Popt nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 1,480 550 318 2,400 3,500 3,100 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] 2,900 4,000 1,500 1,680 612 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1283 Technical data and characteristics 6.2 Synchronous motors Table 6- 1059 SINAMICS, 3-ph. 400 VAC, Smart/Basic Line Module, (SLM/BLM), 1PH8228-2L2 nrated Prated [rpm] [kW] 2,500 270 Mrated Irated Popt nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 1,031 570 278 3,000 3,500 3,100 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] >3,500 4,000 2,250 1,400 762 1PH8 main motors 1284 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Technical data and characteristics 6.2 Synchronous motors Table 6- 1060 SINAMICS, 3-ph. 400 VAC, Active Line Module, (ALM), 1PH8228-2L2 nrated Prated Mrated Irated Popt nopt nmax nmax, Br nmax, Inv [rpm] [kW] [Nm] [A] [kW] [rpm] [rpm] [rpm] [rpm] Mmax [Nm] 2,900 283 932 520 286 3,200 3,500 3,100 >3,500 4,000 2,500 270 1,031 570 Imax [A] M0 [Nm] I0 [A] 2,250 1,400 762 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1285 Technical data and characteristics 6.2 Synchronous motors Table 6- 1061 SINAMICS, 3-ph. 480 VAC, Smart/Basic/Active Line Module, (SLM/BLM/ALM), 1PH8228-2L2 nrated Prated Mrated Irated Popt [rpm] [kW] 3,200 291 nopt nmax nmax, Br [Nm] [A] [kW] [rpm] [rpm] [rpm] 868 485 291 3,350 3,500 3,100 nmax, Inv [rpm] Mmax [Nm] Imax [A] M0 [Nm] I0 [A] >3,500 4,000 2,250 1,400 762 1PH8 main motors 1286 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Preparing for use 7 Transportation Note Transportation conditions Comply with the local national regulations for the transportation of motors. Note Observing the notes Observe the information on the original packaging and in the operating instructions when transporting and setting down the motor. NOTICE Bearing damage during transport If the customer has already mounted parts, for example coupling, belt pulley, etc., the bearing can be damaged during transport. * In this case, make sure that the customer uses a rotor locking device. Storage Note Storage If possible, store the motor in its original packaging. 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1287 Preparing for use NOTICE Frost damage to water-cooled motors Water-cooled motors can be damaged by frost * Remove the liquid coolant before storage and blow out the cooling ducts with compressed air. Preserve the free shaft ends, sealing elements, and flange surfaces with a protective coating. NOTICE Seizure damage to bearings If the motors are stored incorrectly, bearing seizure damage can occur, e.g. brineling, as a result of vibration. * Comply with the storage conditions. Storage conditions Please observe the warning instructions on the packaging and labels. Store the motor in a dry, dust-free, and vibration-free indoor storage facility. Adhere to the following values: vrms < 0.2 mm/s Max. temperatures: -15 C to 55 C Mean relative humidity < 60 % Note Replacing roller bearings * Even if the motor was stored for more than two years under favorable conditions (i.e. in a dry, dust-free room that is not susceptible to vibration), you must replace the bearings. * If the motor was stored under unfavorable conditions, you must replace the bearings after approx. 18 months. 1PH8 main motors 1288 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Preparing for use Note Observing the notes Observe the information in the operating instructions when storing the motor. 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1289 Preparing for use 1PH8 main motors 1290 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Electrical connection 8.1 8 Permissible line system configurations In combination with the drive system, the motors are generally approved for operation on TN and TT systems with grounded neutral and on IT systems. In operation on IT systems, the occurrence of a first fault between an active part and ground must be signaled by a monitoring device. In accordance with IEC 60364-4-41 it is recommended that the first fault should be eliminated as quickly as practically possible. In systems with a grounded external conductor, an isolating transformer with grounded neutral (secondary side) must be connected between the line supply and the drive system to protect the motor insulation from excessive stress. The majority of TT systems have a grounded external conductor, so in this case an isolating transformer must be used. 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1291 Electrical connection 8.2 Circuit diagram of the motor 8.2 Circuit diagram of the motor You will find information on the circuit and on connecting the motor winding and the auxiliary equipment (e. g. temperature sensor, anti-condensation heating, etc.) in the circuit diagram. The circuit diagram is in the terminal box for the cable connection. 1PH8 main motors 1292 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Electrical connection 8.3 System integration 8.3 System integration 8.3.1 SINAMICS drive I/O Figure 8-1 SINAMICS S120 system overview 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1293 Electrical connection 8.3 System integration 8.3.2 Connecting-up information Please observe the rating plate data (type plate) and circuit diagram in the terminal box. Use sufficiently dimensioned connection cables. Note System compatibility for connection System compatibility is guaranteed only if shielded power cables are used and the shield is conductively bonded over a large area to the metal motor terminal box (using metal EMC cable gland) or by a power connector. Shields must be incorporated in the protective grounding concept. Protective ground should be connected to conductors that are open-circuit and that are not being used and also electrical cables that can be touched. If the brake feeder cables in the SIEMENS cable accessories are not used, then the brake conductor cores and shields must be connected to the cabinet ground (open-circuit cables result in capacitive charges!) Use EMC cable glands for fixed cable entries. The cable glands are screwed into the threaded holes of the terminal box. Openings that are not used must be closed using an appropriate metal cap. Note Connection with aluminum conductors Aluminum conductors can also be used on motors with a greater power and current (e.g. SH 280). If you are using aluminum conductors, additionally comply with the following: * Use only cable lugs that are suitable for connecting aluminum conductors. * Immediately before inserting the aluminum conductor, remove the oxide layer from the contact areas on the conductor and/or the mating piece, by brushing or filing. * Then grease the contact areas immediately using neutral vaseline in order to avoid reoxidation. Note Terminal boxes with aluminum connection bars In the terminal boxes with aluminum connection bars (type 1XB7), copper (Cu) cables with copper (Cu) cable lugs can also be connected. 1PH8 main motors 1294 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Electrical connection 8.3 System integration Internal equipotential bonding The potential bonding between the grounding terminal in the box enclosure and the motor housing is established through the terminal box fixing screws. The contact locations underneath the screw/bolt heads are bare and are protected against corrosion. Equipotential bonding between the terminal box cover and the terminal box enclosure can be provided using the normal fixing screws of the cover. Note Extra grounding terminals in terminal box for SH 280 (option Q00) For large transmission powers, symmetrical power cables with a grounding conductor split into 3 are used in some cases. To be able to connect this large number of grounding conductors in the terminal box, a grounding bar with a larger number of terminals can also be mounted on the SH 280 with option Q00 (see Increased number of grounding terminals in the terminal box (Page 204)). Shaft height Terminal box Quantity Quantity Connecting terminals Connecting terminals (grounding) (Grounding) SH Type Standard Option Q00 280 1XB7712-P... 4 x M16 12 x M6 Motor and connecting cables Twisted or three-core cables with additional ground conductor should be used as motor feeder cables. The insulation should be removed from the ends of the conductors so that the remaining insulation extends up to the cable lug or terminal. The connecting cables should be freely arranged in the terminal box so that the protective conductor has an overlength and the cable conductor insulation cannot be damaged. Connecting cables should be appropriately strain relieved. Take special care that the required air clearances are actually maintained: - Up to SH 160, a minimum of 4.5 mm - From SH 180 and above, at least 10 mm After connecting up, the following should be checked/tested The inside of the terminal box must be clean and free of any cable pieces All of the terminal screws must be tight The minimum air distances must be maintained The cable glands must be reliably sealed 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1295 Electrical connection 8.3 System integration Unused cable glands must be closed and the plugs must be tightly screwed in place All of the sealing surfaces must be in a perfect condition Connecting the ground conductor The ground conductor cross-section must be in full conformance with the installation regulations, e.g. acc. to IEC/EN 60204-1. For shaft heights 225 and 280, the ground conductor must be additionally connected to the motor bearing end shield. There is a clamping lug for the ground conductor at the designated connection point. This is suitable for connecting multi-conductor cables with cable lugs or ribbon cables with the appropriate conductor terminations. Figure 8-2 Clamping lug for grounding conductors (SH225 and SH280) Please note the following when connecting-up: The connecting surface must be bare and must be protected against corrosion using a suitable medium, e.g. with acid-free Vaseline There is a spring washer and normal washer underneath the screw head The minimum necessary screw-in depth and the tightening torque for the clamping bolts must be maintained Table 8- 1 8.3.3 Screw-in depth and tightening torque Screw Penetration depth: Tightening torque M8 x 30 > 8 mm 20 Nm Routing cables in a damp environment Note Routing cables in humid/moist environments If the motor is mounted in a humid environment, the power and signal cables must be routed as shown in the following figure. 1PH8 main motors 1296 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Electrical connection 8.3 System integration Figure 8-3 8.3.4 Principle of cable routing in a wet/moist environment Power connection WARNING Thermally damaged connecting cables If connection cables have a conductor cross section that is too small for the application, the connection cables can be thermally damaged. This can result in personal injury and damage to property due to electric shock and fire hazard. * Carefully observe the current which the motor draws for your particular application! Adequately dimension the connecting cables according to IEC 60204-1 or IEC 60364-552. Figure 8-4 Power cable 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1297 Electrical connection 8.3 System integration Terminal box connection The designation of the mounted terminal box as well as the details on the power connection for the line supply cables can be taken from the following table. A circuit diagram to connectup the motor winding is provided in the terminal box when the motors are shipped. Figure 8-5 Circuit diagram Note Connecting temperature sensors and PTC thermistors The spare temperature sensor (option A25 for shaft heights 80 to 160, standard for shaft height 180 and more) and the chain of PTC thermistors for alarm/trip (option A12) are connected to a signal terminal block in the terminal box. Star/delta connection in the terminal box (SH80 to SH160) The star/delta connection can be implemented via an external contactor circuit or as permanent setting in the terminal box. Figure 8-6 Fixed star/delta connection in the terminal box 1PH8 main motors 1298 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Electrical connection 8.3 System integration Current-carrying capacity for power and signal cables The current carrying capacity of PVC/PUR-insulated copper cables is specified for routing types B1, B2, C and E under continuous operating conditions in the table with reference to an ambient air temperature of 40 C. For other ambient temperatures, the values must be corrected by the factors from the table of derating factors. Table 8- 2 Cable cross section and current-carrying capacity Cross section Current-carrying capacity rms; AC 50/60 Hz or DC for routing type [mm2] B1 [A] B2 [A] C [A] E [A] 4.4 Electronics (according to EN 60204-1) 0.20 - 4.3 4.4 0.50 - 7.5 7.5 7.8 0.75 - 9 9.5 10 Power (according to EN 60204-1) 0.75 8.6 8.5 9.8 10.4 1.00 10.3 10.1 11.7 12.4 1.50 13.5 13.1 15.2 16.1 2.50 18.3 17.4 21 22 4 24 23 28 30 6 31 30 36 37 10 44 40 50 52 16 59 54 66 70 25 77 70 84 88 35 96 86 104 110 50 117 103 125 133 70 149 130 160 171 95 180 165 194 207 120 208 179 225 240 Power (according to IEC 60364-5-52) 150 2391) 2061) 2591) 2761) 185 2741) 2351) 2961) 3151) > 185 Values must be taken from the standard 1) Extrapolated values Table 8- 3 Derating factors for power and signal cables Ambient air temperature [C] Derating factor according to EN 60204-1, Table D1 30 1.15 35 1.08 40 1.00 45 0.91 50 0.82 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1299 Electrical connection 8.3 System integration Ambient air temperature [C] Derating factor according to EN 60204-1, Table D1 55 0.71 60 0.58 Assignment, terminal boxes and max. cross-sections Table 8- 4 Terminal box type Data for terminal box Shaft height Cable entry (power) Cable entry (external signals) Max. external cable diameter Number of main terminals 2) [mm] Max. crosssection per terminal [mm2] Max. current per terminal [A]3) gk803 SH80 1 x M25 x 1.5 1 x M16 x 1.5 20 Phases: 3 x M5 Grounding: 2 x M5 1 x 10 52 gk806 SH80 1 x M25 x 1.5 1 x M16 x 1.5 1) 20 Phases: 6 x M5 Grounding: 2 x M5 1 x 10 52 gk813 SH100 1 x M32 x 1.5 1 x M16 x 1.5 1) 24.2 Phases: 3 x M5 Grounding: 2 x M5 1 x 16 70 gk823 SH100 1 x M32 x 1.5 1 x M16 x 1.5 1) 24.2 Phases: 3 x M5 Grounding: 2 x M5 1 x 16 70 gk826 SH100 1 x M32 x 1.5 1 x M16 x 1.5 1) 24.2 Phases: 6 x M5 Grounding: 2 x M5 1 x 10 52 gk833 SH132 1 x M40 x 1.5 1 x M16 x 1.5 1) 32 Phases: 3 x M6 Grounding: 2 x M6 1 x 35 110 gk843 SH132 1 x M50 x 1.5 1 x M16 x 1.5 1) 38 Phases: 3 x M6 Grounding: 2 x M6 1 x 50 133 gk846 SH132 1 x M50 x 1.5 1 x M16 x 1.5 1) 38 Phases: 6 x M6 Grounding: 2 x M6 1 x 25 88 gk863 SH160 1 x M50 x 1.5 1 x M16 x 1.5 1) 38 Phases: 3 x M6 Grounding: 2 x M6 1 x 50 133 gk873 SH160 1 x M63 x 1.5 1 x M16 x 1.5 1) 42.6 Phases: 3 x M6 Grounding: 2 x M6 1 x 50 133 gk874 SH160 1 x M63 x 1.5 1 x M16 x 1.5 1) 42.6 Phases: 3 x M10 Grounding: 2 x M6 2 x 70 240 1XB7322- SH180 2 x M50 x 1.5 P05 to SH280 1 x M16 x 1.5 4) 38 Phases: 3 x M12 Grounding: 4 X M6e 2 x 50 210 1XB7422- SH180 2 x M63 x 1.5 P06 to SH280 1 x M16 x 1.5 4) 53 Phases: 3 x M12 Grounding: 4 x M8 2 x 70 270 1) 1PH8 main motors 1300 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Electrical connection 8.3 System integration Terminal box type Shaft height Cable entry (power) Cable entry (external signals) Max. external cable diameter Number of main terminals 2) [mm] Max. crosssection per terminal [mm2] Max. current per terminal [A]3) 1XB7700- SH225 3 x M75 x 1.5 P02 and SH280 1 x M16 x 1.5 68 Phases: 3 x 2 x M12 Grounding: 3 x clamping plate 3 x 150 700 1XB7712- SH225 4 x M75 x 1.5 P03 and SH280 1 x M16 x 1.5 4) 68 Phases: 3 x 4 x M16 Grounding: 4 x M16 4 x 185 1,150 4) 1) M16 x 1.5 thread arranged at 90 angle to signal connection; thread only with options A12, A25 and encoder version A (without encoder) 2) Depending on the version of metric cable gland (based on the MOTION-CONNECT cable type and cable glands from HUGRO or from AGRO) 3) Current-carrying capacity based on EN 60204-1 and IEC 60364-5-52, routing type E 4) M16 x 1.5 thread arranged opposite to the signal connection (lateral to the cable entry plate); thread only for option A12 and encoder version A (without encoder) Note Terminal box type 1XB7700-P02 For cable entry, 3 cable glands can only be fit in if cable glands from AGRO or HUGRO are used. Cable glands from Pflitsch or Lapp, for example, are larger and it is not possible to fit 3 of them into the available space. Terminal box version Terminal screw M5 Grounding screw M5 Insulation strips Figure 8-7 Terminal box gk803, 3-pole (SH 80) 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1301 Electrical connection 8.3 System integration M5 connecting studs Grounding screw M5 Insulation strips Jumper Figure 8-8 Terminal box gk806, 6-pole (SH 80) (can be switched between star and delta) Terminal screw M5 Grounding screw M5 Insulation strips Figure 8-9 Terminal box gk813, 3-pole (SH 100) 1PH8 main motors 1302 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Electrical connection 8.3 System integration Terminal screw M5 Grounding screw M5 Insulation strips Figure 8-10 Terminal box gk823, 3-pole (SH 100) Terminal screw M5 Grounding screw M5 Insulation strips Jumper Figure 8-11 Terminal box gk826, 6-pole (SH 100) (can be switched between star and delta) Note Star/delta connection A star/delta connection is implemented by means of an external contactor circuit or as a fixed configuration in terminal box gk806 for SH 80 and in terminal box gk826 for SH 100. Standard configuration: Star connection via jumpers 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1303 Electrical connection 8.3 System integration Terminal screw M6 M6 grounding screw Insulation strips Figure 8-12 Terminal box gk833 (SH 132) and gk863 (SH 160), 3-pole Terminal screw M6 M6 grounding screw Insulation strips Figure 8-13 Terminal box gk843 (SH 132) and gk873 (SH 160), 3-pole 1PH8 main motors 1304 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Electrical connection 8.3 System integration Terminal stud M6 Jumper M6 grounding screw Insulation strips Figure 8-14 Terminal box gk846 (SH 132) and gk876 (SH 160), 6-pole (can be switched between star and delta) Terminal screw M10 M6 grounding screw Insulation strips Figure 8-15 Terminal box gk874 (SH 160), 3-pole (only for synchronous motors) 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1305 Electrical connection 8.3 System integration Connection screw M5 for SH80/100 Connection screw M6 for SH132/160 Grounding screw M5 for SH80/100 Grounding screw M6 for SH132/160 Insulation strips Figure 8-16 Terminal boxes gk803 (SH 80), gk823 (SH 100), gk843 (SH 132), gk873 (SH 160), 3pole, cable entry DE (drive end) Note Cable exit direction DE The motor with the cable exit direction DE has a "D" in the 15th position of the Article No. Note The internal motor cables are mounted on the NDE side on the 3-pole terminal board. The terminal box gk874 (SH 160), 3-pole (only for synchronous motors) is not possible. 1PH8 main motors 1306 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Electrical connection 8.3 System integration Main terminal Ground terminal Signal connection terminal Signal connection Figure 8-17 Terminal box 1XB7322-P05 (SH 180 to SH 280) Main terminal Ground terminal Signal connection terminal Signal connection Figure 8-18 Terminal box 1XB7422-P06 (SH 180 to SH 280) 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1307 Electrical connection 8.3 System integration Main terminal Ground terminal Signal connection terminal Signal connection Figure 8-19 Terminal box 1XB7700-P02 (SH 225 and SH 280) Main terminal Ground terminal Signal connection terminal Figure 8-20 Terminal box 1XB7712-P03 (SH 225 and SH 280) 1PH8 main motors 1308 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Electrical connection 8.3 System integration Note Signal connection for special orders The signal connection may differ from the standard layout in the case of special orders. In the version without speed encoder, there is a connection thread M16 x 1.5 . Power connector connection Use connector size 1.5. Assign the connector as shown in the "Power connector 1.5" diagram. Connect the protective conductor. Figure 8-21 Power connector, size 1.5 (view of connector pins) Connector Connector size 1.5 Rotation range Maximum torque 270 20 Nm Note Rotating the connectors * The permissible rotation range must not be exceeded. * In order to guarantee the degree of protection, max. 10 revolutions are permissible. * Connectors should be rotated using the matching mating connector located on the connector thread. Only rotate Sensor Modules by hand. The use of pipe wrenches, hammers, or similar is not permitted. 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1309 Electrical connection 8.3 System integration Use connector size 3. Assign the connector as shown in the "Power connector 3" diagram. Connect the protective conductor. Figure 8-22 Power connector, size 3 (looking onto the connector pins) Star/delta connection via an external contactor circuit When induction motors (SH 80 to SH 160) are used, it is possible to select one of the following operating modes: Star connection Delta connection Circuit to implement star-delta switchover For induction motors, all six connection leads of the three winding phases are fed out to be able to select the various operating modes. The changeover is carried out outside the spindle using switching devices and equipment that are not included with the motor spindle (i.e. these devices are not included in the scope of delivery). Note Star/delta connection When changing over the circuit configuration (star-delta), the appropriate data set for the closed-loop motor control must also be changed-over. A changeover may only be made when the spindle is in a no-load condition and with the power module pulses inhibited. For information about the circuit to implement the star-delta changeover, refer to the following diagram and SINAMICS S120 Function Manual (FH1). 1PH8 main motors 1310 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Electrical connection 8.3 System integration Using the star connection The star connection offers some advantages at low speeds. The maximum torque in the star connection is approximately twice as high as in the delta connection. However, due to the higher reactive power requirement of the star connection, the available torque in the uppermost speed range is significantly restricted. This means that the star connection should only be activated when machining which requires a high torque in the lower speed range. An example of such a machining operation is roughing. Using the delta connection Although the delta connection provides, in the lower speed range, a lower maximum torque than the star connection, the torque remains available up to high speeds. This means that the delta connection should be activated for all machining operations which are carried out in the medium and high speed ranges. 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1311 Electrical connection 8.3 System integration Connection diagram for Y/D changeover Figure 8-23 Connection diagram for Y/D changeover with SINAMICS 1) Safe operating stop cannot be guaranteed by simply opening K1 and K2. Therefore, for safety reasons there should be electrical isolation provided by contactor Kx. This contactor may only be switched-in the no-current condition, i.e. the pulse enable must be withdrawn 40 ms before the contactor is opened (de-energized). 2) Terminal X3 of the voltage limiting module VPM should be wired to a digital input of the control unit on which the assigned 1PH8 motor spindle is also controlled. For the case that several VPMs are used, each terminal must be wired to a separate digital input of the relevant Control Unit. If an armature short-circuit occurs (terminal X3 has opened), the pulses of the relevant axis must be inhibited. To achieve this, the digital input used is interconnected to the control bit OFF2 (pulse inhibit) via p0845 = r0722.XX. Further information can be found in the SINAMICS S120 Function Manual. 1PH8 main motors 1312 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Electrical connection 8.3 System integration 8.3.5 External fan Table 8- 5 Connected loads for external fans Shaft height SH Fan motor: Max. current consumption [A] Forced ventilation 230 V 1 AC/50 Hz (10 %) 80 0.33 0.25 0.32 NDE --> DE 0.20 0.16 0.19 DE --> NDE Forced ventilation 3-ph. 400 VAC / 50 Hz (10 %) 400 V 3 AC/60 Hz (10 %) 480 V 3 AC/60 Hz (10 %) 100 0.12 0.09 0.12 NDE --> DE 0.13 0.09 0.13 DE --> NDE 0.13 0.16 0.17 NDE --> DE 0.21 0.19 0.23 DE --> NDE 0.17 0.22 0.22 NDE --> DE 0.26 0.32 0.33 DE --> NDE 132 160 230 V 1 AC/60 Hz (10 %) Air flow direction 265 V 1 AC/60 Hz (10 %) Forced ventilation (EC fan) 1-ph. 200 ... 277 VAC / 50 Hz, 60 Hz (10 %) 180 1.2 ... 0.88 NDE --> DE DE --> NDE 225 1.9 ... 1.35 NDE --> DE DE --> NDE Forced ventilation 3-ph. 400 VAC / 50 Hz (10 %) 3-ph. 400 VAC / 60 Hz (+5 %, -10 %) 3-ph. 480 VAC / 60 Hz (+5 %, -10 %) 280 2.55 2.5 2.5 NDE --> DE DE --> NDE Note For EC fans for SH 180 and SH 225, as a result of the electronic input circuitry the current drawn can briefly reach four times the specified current. 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1313 Electrical connection 8.3 System integration Recommended connection Connect the external fan via the terminal box of the external fan or optionally via the power connector. Implement operation of the fans via the motor circuit breaker. A simple conductor protection is sufficient for the EC fans. Figure 8-24 Recommended connection Note Single-phase fan connection If a three-pole motor circuit breaker is used for a single-phase fan connection (SH 80), the three current paths must be connected in series (see Fig.). If only one current path were used, many circuit breakers would trip too early because they often also monitor balanced load or voltage on the three phase conductors. Whether this circuit is permissible with electronic motor circuit breakers must be determined on a case-bycase basis from the product data sheets of the manufacturer. 1PH8 main motors 1314 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Electrical connection 8.3 System integration Figure 8-25 Single-phase connection Connection through terminal box Figure 8-26 Connection external fan terminal box Connection by power connector Figure 8-27 Connecting an external fan, SH 80 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1315 Electrical connection 8.3 System integration Figure 8-28 Connecting an external fan, SH 100 to SH 132 Note Rotating the connectors * The permissible rotation range must not be exceeded. * In order to guarantee the degree of protection, max. 10 revolutions are permissible. * Connectors should be rotated using the matching mating connector located on the connector thread. Only rotate Sensor Modules by hand. The use of pipe wrenches, hammers, or similar is not permitted. Connector Connector size 1.0 Rotation range Maximum torque 270 12 Nm Note Scope of delivery The mating connector is not included in the scope of delivery. Article number mating connector size 1 (with full thread) 6FX2003-0LU00 Note Prefabricated cables Prefabricated cables can be ordered with the following article number: 6FX002-5CG01-0 1PH8 main motors 1316 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Electrical connection 8.3 System integration EC external fan for shaft heights 180 to 280 EC external fans are installed in forced ventilated motors of the 1PH8 series. These are especially designed fan units for this motor series, with a permanently set operating speed. EC external fans contain high-efficiency electronically commutated motors with permanent magnets. They are speed-controlled by an integrated controller. The EC external fans meet the general requirements of EN 61800-2 for variable-speed electrical drives and are designed for single-quadrant operation. Figure 8-29 EC external fans with the air flow direction DE NDE and air flow direction NDE DE External fans with filter unit (option G14) The version for the air flow direction NDE DE can be optionally expanded with a filter unit (option G14). The filter corresponds to DIN EN 779 of filter class G3. Figure 8-30 EC external fans with air flow direction NDE DE and filter unit 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1317 Electrical connection 8.3 System integration Connecting an external fan (type 1PH818, 1PH822) The external fan is connected in the external fan terminal box. If necessary, you can rotate the external fan through 90. Figure 8-31 External fan terminal box (schematic representation) WARNING Short circuit due to standing water If you rotate the external fan through 90, the cable outlet must not face upward. Water that accumulates at the cable glands can result in a short circuit. * Rotate the terminal box cover of the external fan through 180. 1PH8 main motors 1318 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Electrical connection 8.3 System integration Connection on the terminal box 1 M20 cable entry for line power connection 2 M20 cable entry for control (optional) Figure 8-32 Connection cover of the terminal box In the delivery condition, the two cable entries are sealed. Cable entry with a plug. is intended for the line power connection and is therefore only sealed Cable entry is intended for the optional control connection and is fitted with a screw plug. Note Cable gland The cable glands are not included in the scope of supply. Suitable cable glands must be chosen for connecting the cable. The general connection instructions must be observed. The continuous sealing of the cable gland toward the terminal box and the cable must be ensured. 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1319 Electrical connection 8.3 System integration Wiring diagram 1PH8 main motors 1320 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Electrical connection 8.3 System integration 1 Line voltage (see Chapter "Connection for terminal box") 2 Relay output (K1) for alarm 3 MODBUS (RS-485) interface (only accessible for Siemens Service) 4 Factory-mounted jumper between 10V and E1 for 100 % operating speed 5 Input for speed setting via 0...10V signal or potentiometer (Ri > 100 k) 6 Power supply 10V DC (Imax 50 mA) Note Terminal block The terminal block is led out with spring-loaded terminals. A conductor cross section 0.08 to 1.5 mm2 can be connected to the terminals. A conductor cross section of 1.5 mm2 is recommended. Note Relay output (K1) An external alarm can be issued via the isolated contact of the integrated relay. During operation, the relay picks up, i.e. connections "11" and "14" are jumpered. If a fault occurs, the relay drops out (contact load max. 250 V AC 2 A). Note Factory-mounted jumper between 10V and E1 In the delivery condition, a jumper is fitted between the voltage supply "10 V" and the analog input "E1." 100 % of the speed is achieved during operation in this way. After the line voltage has been switched on and after a startup time of approx. 20 seconds, the fan is operated at a constant speed of 100 % (rated speed). Note Speed control via setting signal Ventilation can be adjusted to the duty cycle and the load of the 1PH8 motor. The factorymounted jumper between 10V and E1 must be removed in this case. The speed of the fan can be set in the range 50 ...100% via a setting signal (0...10V). Contact Siemens Technical Support for more information and support. 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1321 Electrical connection 8.3 System integration Diagram of control via an external setting signal NOTICE Removing the factory-mounted jumper The 1PH8 motor can overheat if the external EC fan is operated at low fan speeds as a result of the setpoint signal it receives. * Monitor the motor using the integrated temperature sensors. * Integrate the temperature monitoring into the interlocking circuit. If the company operating the plant or system removes the jumper (which was inserted in the factory), that company becomes responsible for the functional safety of the drive, especially if the safety instructions are not heeded. Line connection: Fuse protection The EC external fans have integrated overload protection, making an external motor protection device (e.g. motor circuit breaker) unnecessary. A simple conductor protection is sufficient. Simple conductor protection with a fuse or MCB: Fuse MCB Conductor cross section Conductor cross section *AWG 16 VDE UL VDE mm2 16 A 15 A C16A 1.5 1PH8 main motors 1322 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Electrical connection 8.3 System integration (* AWG = American Wire Gauge) Residual-current protective device Only RCDs that are sensitive to universal current (type B or B+) are permissible. Personal protection is not possible if the device is operated with RCDs, as is also the case for frequency converters. When the power supply of the device is switched on, charging current pulses can occur due to the capacitors. In the integrated EMC filter, this can cause the RCDs to trip instantaneously. We recommend residual-current operated circuit breakers with a tripping threshold of 300 mA and delayed tripping (super-resistant, characteristic K). Use in IT systems WARNING Risk of electric current In an IT system, the neutral point of the voltage supply is not grounded. If a short-circuit occurs between a phase (e.g. "L1") and the protective conductor "PE," the protective conductor is at phase potential. A voltage higher than the line voltage of the device must never be applied between the line connection and the protective conductor "PE"! The single-phase EC external fans can be used in an IT system. In three-phase IT systems, the following must be considered for use. During a ground fault of an unused line phase, the potential relative to "PE" must not be higher than the specified line voltage of the device (at either of the two supply connections). To ensure fault-free operation on the IT system, the "GND" potential of the control connections must be connected to the protective conductor potential. The following consequences of this connection must be observed for the control connections (except for relay contacts): 1. Only connect using cables that are suitable for the line voltage and environment. 2. Only connect via separate isolation amplifiers. Three-phase external fan for shaft heights 180 and 225 Instead of the standard EC external fans for shaft heights 180 and 225, the motors can also be implemented with a three-phase conventional external fan. These fans can be ordered with the option L75. 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1323 Electrical connection 8.3 System integration Connecting an external fan The external fan has a terminal box that is mounted on the external fan motor. Air flow direction 400 V 3 AC 400 V 3 AC 480 V 3 AC / 50 Hz / 60 Hz (1) / 60 Hz (1) ( 10 %) ( 10 %) (+5 %, 10 %) Sound pressure level LpA (1 m) Motor + external fan unit 50 Hz operation Air flow rate at 50 Hz, approx. Tolerance + 3 dB Rated pulse frequency 2 kHz [A] [A] [A] [dB] [m3/s] 2.4 2.4 2.3 76 (2) 0.17 2.4 2.4 2.3 76 (2) 0.31 2.4 2.4 2.3 76 (3) 0.21 2.4 2.4 2.3 76 (3) 0.33 1PH8 forced ventilation, degree of protection IP55, L75 1PH818.-...0.-...1-Z DE NDE 1PH818.-...1.-...1-Z NDE DE 1PH822.-...0.-...1-Z DE NDE 1PH822.-...1.-...1-Z NDE DE 1PH8 open-circuit ventilation, degree of protection IP23, L75 1PH818.-...3.-...1-Z DE NDE 1PH818.-...4.-...1-Z NDE DE 1PH822.-...3.-...1-Z DE NDE 1PH822.-...4.-...1-Z NDE DE (1) 60 Hz operation only permissible with throttle plate (2) Speed ranges: 1PH818. up to 5000 rpm, 1PH822. up to 3500 rpm (3) Speed ranges: 1PH818. up to 3000 rpm, 1PH822. up to 2000 rpm NOTICE Incorrect direction of rotation The external fan is only suitable for one direction of rotation. Operation with the wrong direction of rotation can destroy the motor. * If necessary, change the direction of rotation by interchanging two phase conductors in the terminal box. The direction of rotation arrow and the direction of rotation of the fan impeller can be seen at the rear of the fan. 1PH8 main motors 1324 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Electrical connection 8.3 System integration Throttle sheet for operation at 60 Hz When operated from a 60 Hz line supply, you require the air discharge throttle plate provided in the terminal box. NOTICE Operation at 60 Hz The external fan motor can be damaged if it is operated on a 60 Hz line supply. * Use the air discharge throttle plate for operation on a 60 Hz line supply. Screw the air discharge throttle plate to the air discharge mesh. Fixing screws for air discharge throttle metal plate Air discharge throttle metal plate Figure 8-33 Throttle plate for suction-type ventilation (DE to NDE) Fixing screws for air discharge throttle metal plate Air discharge throttle metal plate Figure 8-34 Throttle plate for forced-draft ventilation (NDE to DE) 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1325 Electrical connection 8.3 System integration Note Filter unit (option Q14) If an additional filter unit is required for the three-phase external fan (option L75), the filter unit must be ordered with option Q14 (can only be ordered if the 11th data position is "1" or "4"). 8.3.6 Signal connection DRIVE-CLiQ is the preferred method for connecting the encoder systems to SINAMICS. Motors with a DRIVE-CLiQ interface can be ordered for this purpose. Motors with a DRIVECLiQ interface can be directly connected to the associated motor module via the available MOTION-CONNECT DRIVE-CLiQ cables. The MOTION-CONNECT DRIVE-CLiQ cable is connected to the motor in degree of protection IP67. The DRIVE-CLiQ interface supplies power to the motor encoder via the integrated 24 VDC supply and transfers the motor encoder and temperature signals and the electronic type plate data, e.g. a unique identification number, rating data (voltage, current, torque) to the control unit. The MOTIONCONNECT DRIVE-CLiQ cable is used universally for connecting the various encoder types. These motors simplify commissioning and diagnostics, as the motor and encoder type are identified automatically. Encoder connection on motors with DRIVE-CLiQ Motors with DRIVE-CLiQ interfaces can be directly connected to the corresponding Motor Module via the available MOTION-CONNECT DRIVE-CLiQ cables. This data is transferred directly to the Control Unit. Figure 8-35 Encoder connection on motors with DRIVE-CLiQ 1PH8 main motors 1326 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Electrical connection 8.3 System integration Cables on motors with DRIVE-CLiQ With DRIVE-CLiQ, the same cable is used for all encoder types. Only pre-assembled cables from Siemens (MOTION-CONNECT) may be used. Table 8- 6 6FX Pre-assembled cable 002 - DC - 0 Length 5 MOTIONCONNECT500 max. cable length 100 m 8 MOTIONCONNECT800 max. cable length 50 m For other technical data and length code, refer to Catalog, Chapter "MOTION-CONNECT connection system" Encoder connection on motors without DRIVE-CLiQ If a motor is not equipped with a DRIVE-CLiQ interface, the speed encoder and temperature sensor are connected via a signal connector. Motors that are not equipped with DRIVE-CLiQ require a Sensor Module Cabinet-Mounted (SMC) or a Sensor Module External (SME) when operated with SINAMICS S120. The motor is connected to the SMC or the SME via the signal cable. The SMC or SME is connected to the Motor Module via a MOTION-CONNECT DRIVE-CLiQ cable. Figure 8-36 Encoder connection on motors without DRIVE-CLiQ Cables on motors without DRIVE-CLiQ Prefabricated cables from Siemens (MOTION-CONNECT) must be used. These offer many advantages over self-assembled cables in terms of operational reliability, quality and availability. 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1327 Electrical connection 8.3 System integration For technical data and length code, refer to Chapter "MOTION-CONNECT connection system" in catalog PM 21N or NC 61. 1PH8 main motors 1328 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Dimension drawings 9 CAD CREATOR Thanks to its easy to understand interface, the CAD CREATOR allows you to find the following quickly dimension drawings 2D/3D CAD data and supports you in the creation of plant/system documentation regarding project-specific information. The data for motors, drives and CNC controls is currently available in the online version. You can find further information on the Internet at: http://www.siemens.com/cadcreator Motors 1FK7, 1FT7, 1FT6 synchronous motors 1FE1 built-in synchronous motors 1FW3 complete torque motors 1FW6 built-in torque motors 1FK7, 1FT7, 1FT6 geared motors 1PH8 synchronous/induction motors 1PH7, 1PH4, 1PL6, 1PM4, 1PM6 induction motors 2SP1 motor spindles 1FN3 linear motors SINAMICS S120 Control Units Power Modules (blocksize, chassis) Line Modules (booksize, chassis) Line-side components Motor Modules (booksize, chassis) DC link components Additional system components Load-side power components Encoder system connection MOTION-CONNECT connection system 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1329 Dimension drawings SIMOTION SIMOTION D SIMOTION C SINUMERIK solution line Control systems Operator components for CNC controls Recency of dimension drawings Note Changing motor dimensions Siemens AG reserves the right to change the dimensions of the motors as part of mechanical design improvements without prior notice. This means that dimension drawings can become out of date. Up-to-date dimension drawings can be requested at no charge from your local SIEMENS representative. 1PH8 main motors 1330 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 A Appendix A.1 Description of terms Rated torque MN The rated torque is the torque that is mechanically available at the shaft and can be thermally provided corresponding to the specified operating mode (duty type) according to IEC 60034-1. Rated speed nN This is the speed for which the rated power and the rated torque are defined corresponding to the specified operating mode (duty type) according to IEC 60034-1. Rated voltage VN Voltage between two motor phases for which the rating data (PN, nN, etc.) is defined. The rated voltage definition takes into account magnetic (iron saturation) and thermal factors. Rated current IN This is the current (rms phase value) that flows at the rated speed and rated torque and can be thermally provided according to the specified operating mode (duty type) according to IEC 60034-1. Rated frequency fN Frequency required to obtain the performance ratings (PN, nN, etc.). Rated power PN The rated power is the power that is mechanically available at the shaft and can be thermally provided corresponding to the specified operating mode (duty type) according to IEC 600341. Speed for field weakening with constant power n2 Maximum achievable speed at rated power corresponding to the specified operating mode (duty type) according to IEC 60034-1. 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1331 Appendix A.1 Description of terms No-load current I This is the current (rms phase current) that is required in order to operate the motor under no-load conditions at rated speed without load torque. The no-load current defines the motor magnetization in the base speed range (low speed at the start of field weakening). Maximum speed nmax The maximum permissible speed nmax is determined by mechanical factors. The maximum speed nmax must not be exceeded. NOTICE Motor damage when the maximum speed is exceeded The maximum speed nmax is the highest permissible operating speed. The maximum speed nmax is stamped on the rating plate (nameplate). The motor can be damaged if operated at inadmissible speeds. * Ensure that the maximum permissible speed is not exceeded. Realize this using a suitable control system or activate the speed monitoring function in the drive. If nS1 < nmax, the motor must not be operated at nmax continuously. Unless a different duty cycle (duty cycle duration 10 minutes) is specified, the speed must be reduced as stated below: t1: 1 min---n1= 0 min-1; t2: 6 min---n2= 2/3 nmax ; t3: 3 min---n3= nmax Maximum torque Mmax Torque which is briefly available for dynamic operations (e.g. when accelerating). Max. current Imax This is the current (rms phase value) produced at rated speed (nrated) and maximum torque (Mmax). S1 duty (continuous operation) Operation with a constant load, the duration of which is sufficient that the motor goes into a thermal steady-state condition. S6 duty (intermittent operation) Operation which comprises a sequence of identical duty cycles; each of these duty cycles comprises a time with constant motor load and a no-load time. Unless otherwise specified, the load period refers to a duty cycle of 10 min. 1PH8 main motors 1332 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Appendix A.1 Description of terms E. g. S6-40 % = 4 min load operation, 6 min no-load operation S6-60 % = 6 min load operation, 4 min no-load operation Thermal time constant Tth The thermal time constant defines the temperature rise of the motor winding when the motor load is suddenly increased (step increase) up to the permissible S1 torque. The motor has reached 63% of its S1 final temperature after Tth. 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1333 Appendix A.2 Environmental compatibility A.2 Environmental compatibility Environmental compatibility Environmental aspects during development When selecting supplier parts, environmental compatibility was an essential criteria. Special emphasis was placed on reducing the envelope dimensions, mass and type variety of metal and plastic parts. Effects of paint-wetting impairment substances can be excluded (PWIS test) Environmental aspects during production Supplier parts and the products are predominantly transported in re-usable packing. Transport for hazardous materials is not required. The packing materials themselves essentially comprises paperboard containers that are in compliance with the Packaging Directive 94/62/EC. Energy consumption during production was optimized. Production has low emission levels. Environmental aspects for disposal Motors must be disposed of carefully taking into account domestic and local regulations in the normal recycling process or by returning to the manufacturer. The following must be taken into account when disposing of the motor: Oil according to the regulations for disposing of old oil (e.g. gear oil when a gearbox is mounted) Not mixed with solvents, cold cleaning agents of remains of paint Components that are to be recycled should be separated according to: - Electronics scrap (e.g. encoder electronics, sensor modules) - Iron to be recycled - Aluminum - Non-ferrous metal (gearwheels, motor windings) 1PH8 main motors 1334 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Index A E Absolute encoder AM 2048 S/R, 172 Air discharge throttle metal plate, 1325 Anti-condensation heating, 202 Applications, 25 Axial eccentricity, 139 Axial force, 112 Axial force diagrams SH 100, 128 SH 132, 130 SH 160, 133 SH 180, 136 SH 225, 137 SH 280, 138 SH 80, 126 EC external fan, 1317 EC external fan connected load, 1317 Efficiency, 225, 1087 Encoder, 161 Environmental compatibility, 1334 Explanation of the symbols in the characteristic curves Premium Performance, 223 External fan, 1313 F Fan mounting, 64 Flywheels, 151 Forces due to the rotor weight and spring-loading forces, 125 B Balancing instruction (example), 143 Balancing process, 140 Bearing change interval, 88 Bearing lifetime, 88 Bearing version, 83 C CAD CREATOR, 1329 Certificates EAC, 28 EC Declaration of Conformity, 28 UL and cUL, 28 Compensating coupling, 150 Concentricity, 139 Condensation drain hole, 202 Connecting-up notes, 1295, 1295 Connection value, external fan, 1313 Cooling, 63 D Degree of protection, 80, 81 Disposal, 1334 DRIVE-CLIQ interface, 162 G Ground conductor, 1296 H Heat loss to be dissipated on water-cooled motors, 225, 1087 Holding brake, 184 Holding brakes, 184 Hotline, 7 I I0, 226 Imax, 225 Increased resistance to vibration, 182 Incremental encoder HTL 1024 S/R, 166 Incremental encoder HTL 2048 S/R, 166 Incremental encoder IC 2048 S/R, 169 Incremental encoder IN 256 S/R, 169 Incremental encoder IN 512 S/R, 169 Incremental encoder sin/cos 1Vpp, 169 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1335 Index K P KTY, 159 Popt, 1087 Power factor, 225 Protection against explosion, 176 Pt1000, 159 L Lubrication Permanent lubrication, 88 Relubrication, 89 Relubrication intervals, 90 R Radial eccentricity, 139 Radial force, 110 Radial force diagrams M SH 100, 115 SH 132, 117 M0, 226 SH 160, 119 Magnetizing current, 225 SH 180, 121 Maximum continuous speed, 1087 SH 225, 122 Maximum current, 225, 1087 SH 280, 124 Maximum permissible operating speed, nmax,Inv, 1087 SH 80, 114 Maximum torque, 225, 1087 Rated current, 225, 1087 Misalignment, 150 Rated frequency, 225, 1087 Mmax, 225 Rated power, 225, 1087 Moment of inertia, 225, 1087 Rated speed, 225, 1087 Mounted holding brake Rated torque, 225, 1087 SH 180 and SH 225:Design, 199 Rated voltage, 225, 1087 SH 180 and SH 225:Method of operation, 199 Rating plate, 60 SH 180 to SH 225, 198 Recommended connection, external fan, 1314 SH 80 to SH 160, 188 Replacing the DRIVE-CLiQ interface, 162 SH 80 to SH 160:Construction, 189 SH 80 to SH 160:Method of operation, 189 SH 80 to SH 160:structure:Electrical S connection, 191 Sealing air connection, 174 Mounting and mounting instructions, 147 Siemens Service Center, 7 Star-delta mode, 1310 N Application, 1311 Switchover, 1310 n2, 225 Static current, 1087 Nameplate, 60 Static torque, 1087 Natural frequency when mounted, 149 Storage, 1287 NDE bearing, 91 nmax,Br, 225 nmax1, 225 T nmax2, 225 Technical Support, 7 nmax3, 225 Terminal box connection, 1298 nopt, 1087 Thermal motor protection, 159 Thermal time constant, 225, 1087 O Third-party products, 7, 79 Three-phase external fan, 205 Operation at 60 Hz, 206, 1325 Training, 7 Transportation, 1287 Types of construction, 82 1PH8 main motors 1336 Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 Index U Use for the intended purpose, 25 V Vibration severity limit values, 155 Vibration stressing, 152 Vibration values, 152 W Water cooling, 67 Weight, 225, 1087 1PH8 main motors Configuration Manual, 12/2016, 6SN1197-0AD74-0BP2 1337