For more Information
please call
1-800-Belden1
General Description:
M17/151 type, 29 AWG solid .011" silver-plated copper-covered steel conductor, TFE Teflon® insulation,
copper-tin composite shield (100% coverage), unjacketed.
Physical Characteristics (Overall)
Conductor
AWG:
# Coax AWG Stranding Conductor Material Dia. (mm)
129 Solid SPCCS - Silver Plated Copper Covered Steel 0.2794
Total Number of Conductors: 1
Insulation
Insulation Material:
Insulation Trade Name Insulation Material Dia. (mm)
Teflon® TFE - Tetrafluoroethylene 0.8636
Outer Shield
Outer Shield Material:
Layer # Type Outer Shield Material Coverage (%)
1Tape Copper Foil 100
2Braid Tin-Filled Composite 100
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
Unjacketed
Overall Cable
Overall Nominal Diameter: 1.194 mm
Mechanical Characteristics (Overall)
Operating Temperature Range: -70°C To +200°C
UL Temperature Rating: 105°C (UL AWM Style 10245)
Non-UL Temperature Rating: 200°C
Bulk Cable Weight: 4.465 Kg/Km
Max. Recommended Pulling Tension: 88.964 N
Min. Bend/Installation: 3.175 mm
Min. Flexing Radius: 0.953 cm
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
AWM Specification: UL Style 10245 (30 V 105°C)
EU Directive 2011/65/EU (ROHS II): Yes
EU CE Mark: No
EU Directive 2000/53/EC (ELV): Yes
Page 1 of 3 01-16-2014
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
1674A Coax - 50 Ohm Microwave Cable
EU Directive 2002/95/EC (RoHS): Yes
EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2005
EU Directive 2002/96/EC (WEEE): Yes
EU Directive 2003/11/EC (BFR): Yes
CA Prop 65 (CJ for Wire & Cable): Yes
MII Order #39 (China RoHS): Yes
RG Type: M17/151
Flame Test
Other Flame Test: Horizontal Wire
Suitability
Suitability - Indoor: Yes
Suitability - Outdoor: Yes
Plenum/Non-Plenum
Plenum (Y/N): No
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Impedance (Ohm)
50
Nom. Inductance:
Inductance (µH/m)
0.22967
Nom. Capacitance Conductor to Shield:
Capacitance (pF/m)
96.7895
Nominal Velocity of Propagation:
VP (%)
69.5
Nominal Delay:
Delay (ns/m)
4.79026
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/km)
672.605
Nominal Outer Shield DC Resistance:
DCR @ 20°C (Ohm/km)
26.248
Maximum VSWR:
Freq. (MHz) Max. VSWR
500 1.16:1
1000 1.17:1
3000 1.20:1
5000 1.24:1
10000 1.33:1
15000 1.41:1
18000 1.50:1
20000 1.50:1
Nom. Attenuation:
Freq. (MHz) Attenuation (dB/100m)
500 82.025
1000 120.413
Page 2 of 3 01-16-2014
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
1674A Coax - 50 Ohm Microwave Cable
2000 176.518
3000 220.811
5000 292.665
7000 352.708
10000 429.483
15000 537.428
18000 594.189
20000 629.952
Max. Power Rating:
Freq. (MHz) Rating (W)
500 45
1000 31
2000 22
3000 18
5000 13
7000 11
10000 9.3
15000 7.6
18000 6.9
20000 6.5
Max. Operating Voltage - UL:
Voltage
30 V RMS (UL AWM Style 10245)
Max. Operating Voltage - Non-UL:
Voltage
1000 V RMS
Notes (Overall)
Notes: Teflon® is a registered trademark of E. I. duPont de Nemours and Co. used under license by Belden, Inc.
Put Ups and Colors:
Item # Putup Ship Weight Color Notes Item Desc
1674A TIN100 30 MT 0.091 KG TIN - COLOR #29 TFE BRD TINNED COAX
1674A TIN1000 305 MT 1.814 KG TIN - COLOR #29 TFE BRD TINNED COAX
1674A TIN50 15 MT 0.045 KG TIN - COLOR #29 TFE BRD TINNED COAX
1674A TIN500 152 MT 0.907 KG TIN - COLOR #29 TFE BRD TINNED COAX
Revision Number: 4 Revision Date: 01-15-2014
© 2014 Belden, Inc
All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications
described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not
ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express,
statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or
exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the
compliance date may be in stock at Belden facilities and in our Distributor’s inventory. The information provided in this Product Disclosure, and
the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden’s knowledge,
information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide
for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not
to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for
determining the applicability of legislation and regulations based on their individual usage of the product.
Page 3 of 3 01-16-2014
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
1674A Coax - 50 Ohm Microwave Cable