Philips Components Electrolytic Capacitors General Introduction TRANSLATION OF TECHNICAL TERMS SOME IMPORTANT TERMS DES TERMES IMPORTANTES EINIGE WICHTIGE BEGRIFFE Ambient temperature (Tamb) temperature ambiante Umgebungstemperatur Assessment level niveau d'assurance Gutebestatigungsstufe Axial terminations sorties axiales axiale Anschludrahte Capacitance capacite Kapazitat Charge charge laden Climatic category categorie climatique Klimakategorie Dimensions dimensions Mae Discharge decharge entladen Dissipation factor (tan ) tangente de langle de pertes Verlustfaktor Endurance endurance Dauerspannungsprufung Equivalent series resistance (ESR) resistance serie equivalente aquivalenter Serienwiderstand Equivalent series inductance (ESL) inductance serie equivalente aquivalente Serieninduktivitat Failure rate taux de fiabilite Ausfallrate Frequency (f) frequence Frequenz General purpose grade usage general allgemeine Anforderungen Impedance (Z) impedance Scheinwiderstand, Impedanz Leadless sans fils unbedrahtet Leakage current (Il) courant de fuite Reststrom Long life grade longue duree de vie erhohte Anforderungen Method methode Verfahren Mounting montage Montage No visible damage aucun dommage keine sichtbaren Schaden Open circuit circuit ouvert Unterbrechung Piercing diagram dessin de montage Bohrungsraster Rated capacitance (CR) capacite nominale Nennkapazitat Rated voltage (UR) tension nominale Nennspannung Recovery reprise Nachbehandlung Forming voltage (UF) tension de formation Formierspannung Requirements exigences Anforderungen Reverse voltage (Urev) tension inverse Umpolspannung Ripple current (IR) courant ondule uberlagerter Wechselstrom Short circuit court-circuit Kurzschlu Surface mounting device (SMD) composant pour montage en surface oberflachenmontierbares Bauelement Surge voltage (US) surtension Spitzenspannung Terminations sorties Anschlusse Useful life duree de vie Brauchbarkeitsdauer Visual examination examen visuel Sichtkontrolle 1996 Dec 03 1 Philips Components Electrolytic Capacitors General Introduction CAPACITOR PRINCIPLES Energy content of a capacitor The essential property of a capacitor is to store electrical charge. The amount of electrical charge (Q) in the capacitor (C) is proportional to the applied voltage (U). The relationship of these parameters is: The energy content of a capacitor is given by: 2 1 W E = --- x C x U 2 Q=CxU where: dielectric handbook, halfpage Q = charge in coulombs (C) C = capacitance in farads (F) cathode anode U = voltage in volts (V). The value of capacitance is directly proportional to the (anode) surface area and inversely proportional to the thickness of the dieletric layer, thus: A A C = O x r x ---d d r where: O = absolute permittivity (8.85 x 10-12 F/m) C r = relative dielectric constant (dimensionless) A = surface area MBC552 (m2) NON-POLAR d = thickness of the dielectric (oxide layer in electrolytic capacitors) (m). Fig.1 Equivalent circuit of an ideal capacitor. dielectric layer handbook, full pagewidth cathode current supply anode electrolyte dbook, halfpage aluminium foil (highly etched) R ins C R ESR L ESL aluminium foil MBC551 Al2O3 electrolyte absorbing paper (spacer) POLAR Anode electrode: valve effect metal: aluminium Dielectric: Al2O3 Cathode electrode, solid or non-solid electrolyte depending on technology non-solid: wet electrolyte, spacer and aluminium foil solid: solid electrolyte (e.g. manganese dioxide), graphite and silver epoxy. Fig.2 Equivalent circuit of an electrolytic capacitor. 1996 Dec 03 Al2O3 2 CCA422 Philips Components Electrolytic Capacitors General Introduction ELECTRICAL BEHAVIOUR CHARACTERISTICS OF ELECTROLYTIC CAPACITORS VARY WITH TEMPERATURE, TIME AND APPLIED VOLTAGE. handbook, full pagewidth ripple current capability C frequency frequency leakage current Tan frequency temperature Z leakage current Z ESR ESR load time frequency C/C 0 Z/Z 0 ESR/ ESR0 ESR leakage current C Z 25 oC C Tan ESR Z temperature voltage C failure rate Tan ESR/Z life time temperature ripple current capability failure rate MBC545 - 1 temperature % rated voltage Fig.3 Typical variation of electrical parameters as a function of frequency, ambient temperature, voltage and time. 1996 Dec 03 3 Philips Components Electrolytic Capacitors General Introduction CONSTRUCTION Examples Aluminium can dth Wound cell, consisting of: Insulating sleeve - Aluminium foil anode with aluminium oxide dielectric - Paper spacer impregnated with electrolyte - Aluminium foil cathode Rubber sealing Aluminium connection part Anode and cathode lead, tin plated MSB819 Fig.4 Non-solid Aluminium, radial. handbook, full pagewidth Aluminium can Cathode lead Paper spacer impregnated with electrolyte Sealing disc Blue insulating sleeve Cathode tab foil welded to the bottom of the can Aluminium foil anode with aluminium oxide dielectric Anode lead Aluminium foil cathode Fig.5 Non-solid Aluminium, axial. 1996 Dec 03 4 CCA419 Philips Components Electrolytic Capacitors General Introduction handbook, full pagewidth Aluminium can Wound cell: Aluminium foil anode with aluminium oxide dielectric Paper space impregnated with electrolyte Solvent-resistant shrink sleeve gives high insulation resistance Aluminium foil cathode High-quality low-resistance laser weld between connections and anode/cathode. This means low ESR and ESL Non-porous, teflon-coated hard paper disc and rubber insert for optimum seal Special design so that insertion forces on the connections do not stress the windings mechanically Snap-in connections for fast assembly CCA420 Fig.6 Power non-solid Aluminium, snap-in. andbook, full pagewidth Epoxy resin Cone-shaped flange Cathode lead CCA421 Cathode connection: Silver epoxy on graphite and manganese dioxide Etched aluminium covered with Al2O3 (dielectric) Anode lead Fig.7 Solid Aluminium (SAL), radial. 1996 Dec 03 5 Philips Components Electrolytic Capacitors General Introduction DEFINITIONS OF ELECTRICAL PARAMETERS RATED CAPACITANCE (CR) Capacitance The capacitance value for which the capacitor has been designed and which is usually indicated upon it. AC CAPACITANCE OF AN ELECTROLYTIC CAPACITOR Preferred values of rated capacitance and their decimal multiples are preferably chosen from the E3 series of "IEC Publication 63". The capacitance of an equivalent circuit, having capacitance, resistance and inductance in series, measured with alternating current of approximately sinusoidal waveform at a specified frequency; refer to Fig.8. TOLERANCE ON RATED CAPACITANCE Preferred values of tolerances on rated capacitance are: Standard measuring frequencies for electrolytic capacitors are 100 or 120 Hz. -20/+20%, -10/+50%, -10/+30% and -10/+10%. These values depend on the relevant series. Voltage RATED VOLTAGE (UR) C handbook, halfpage ESR ESL The maximum direct voltage, or peak value of pulse voltage which may be applied continuously to a capacitor at any temperature between the lower category temperature and the rated temperature. VAC MBC549 CATEGORY VOLTAGE (UC) The maximum voltage which may be applied continuously to a capacitor at its upper category temperature. Fig.8 AC equivalent circuit of an electrolytic capacitor. DC CAPACITANCE OF AN ELECTROLYTIC CAPACITOR (FOR TIMING CIRCUITS) TEMPERATURE DERATED VOLTAGE The temperature derated voltage is the maximum voltage that may be applied continuously to a capacitor, for any temperature between the rated temperature and the upper category temperature. DC capacitance is given by the amount of charge which is stored in the capacitor at the rated voltage (UR). DC capacitance is measured by a single discharge of the capacitor under defined conditions. Measuring procedures are described in "DIN 41328, sheet 4" (withdrawn). RIPPLE VOLTAGE (URPL) At any given time, the DC capacitance is higher than the AC capacitance. handbook, halfpage C DC R leak An alternating voltage may be applied, provided that the peak voltage resulting from the alternating voltage, when superimposed on the direct voltage, does not exceed the value of rated direct voltage or fall under 0 V and that the ripple current is not exceeded. REVERSE VOLTAGE (UREV) ESR The maximum voltage applied in the reverse polarity direction to the capacitor terminations. MBC578 SURGE VOLTAGE (US) The maximum instantaneous voltage which may be applied to the terminations of the capacitor for a specified time at any temperature within the category temperature range. Fig.9 DC equivalent circuit of an electrolytic capacitor. 1996 Dec 03 6 Philips Components Electrolytic Capacitors General Introduction Temperature Current CATEGORY TEMPERATURE RANGE LEAKAGE CURRENT (IL) The range of ambient temperatures for which the capacitor has been designed to operate continuously: this is defined by the temperature limits of the appropriate category. Leakage current flows through a capacitor when a DC voltage is applied in correct polarity. It is dependent on voltage, temperature and time. RATED TEMPERATURE Leakage current for acceptance test (IL5) The maximum ambient temperature at which the rated voltage may be continuously applied. MINIMUM STORAGE TEMPERATURE In accordance with international standards ("IEC 384-4", and "CECC 30300") the leakage current (IL5) after 5 minutes application of rated voltage at 20 C, is considered as an acceptance requirement. The minimum permissible ambient temperature which the capacitor shall withstand in the non-operating condition, without damage. The leakage current requirements for the majority of Philips electrolytic capacitors, are lower than specified in "IEC 384-4" or "CECC 30300". If, for example, after prolonged storage and/or storage at excessive temperature (>40 C), the leakage current at the first measurement does not meet the requirements, pre-conditioning shall be carried out in accordance with "CECC 30300 subclause 4.1". Resistance/Reactance EQUIVALENT SERIES RESISTANCE (ESR) The ESR of an equivalent circuit having capacitance, inductance and resistance in series measured with alternating current of approximately sinusoidal waveform at a specified frequency; refer to Fig.8. Leakage current at delivery (IL1 or IL2) In addition to IL5, the leakage current after 1 minute application of rated voltage (IL1) is specified in most of the detail specifications. EQUIVALENT SERIES INDUCTANCE (ESL) The ESL of an equivalent circuit having capacitance, resistance and inductance in series measured with alternating current of approximately sinusoidal waveform at a specified frequency; refer to Fig.8. For some series this value is specified after 2 minutes (IL2). Operational leakage current (IOP) DISSIPATION FACTOR, (TANGENT OF LOSS ANGLE; tan ) After continuous operation (1 hour or longer) the leakage current will normally decrease to less than 20% of the 5 minute value (IL5). The power loss of the capacitor divided by the reactive power of the capacitor at a sinusoidal voltage of specified frequency: The operational leakage current depends on applied voltage and ambient temperature; see Tables 1 and 2. tan = ESR x 2 fC (approximation formula). IMPEDANCE (Z) Leakage current after storage with no voltage applied (shelf life) The impedance () of an electrolytic capacitor is given by capacitance, ESR and ESL in accordance with the following equation (see Fig.10): Z = If non-solid electrolytic capacitors are stored above room temperature for long periods of time, the oxide layer may react with the electrolyte, causing increased leakage current when switched on for the first time after storage. 2 1 2 ESR + 2 f ESL - -------------- 2 f C 1996 Dec 03 7 Philips Components Electrolytic Capacitors Table 1 General Introduction Typical multiplier of operational leakage current as a function of ambient temperature (as far as allowed for the corresponding series) SYMBOL MULTIPLIER Tamb (C) -55 -40 -25 0 20 45 65 85 105 125 IOP/IL <0.5 0.5 0.6 0.8 1 1.5 2.5 4 7 10 Table 2 Typical multiplier of operational leakage current as a function of applied voltage SYMBOL MULTIPLIER U/UR <0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 IOP/IL 0.1 0.15 0.2 0.3 0.4 0.5 0.65 0.8 1 This temperature rise is the result of the balance between heat generated by electric losses: MBC550 handbook, halfpage 2 f L P = IR2 ESR ESR and the carried off heat by radiation, convection and conduction: P = x x 1 2 fC IR can be determined by the equation: Z IR = Fig.10 Vector diagram showing the AC parameters of a capacitor. where: = difference of temperature between ambient and case surface Ripple current (IR) A = geometric surface area of the capacitor Any pulsating voltage (or ripple voltage superimposed on DC bias) across a capacitor results in an alternating current through the capacitor. = specific heat conductivity. The heat, generated by ripple current, is an important factor of influence for non-solid electrolytic capacitors for calculating the useful life under certain circumstances. Because of ohmic and dielectric losses in the capacitor, this alternating current produces an increase of temperature in the capacitor cell. In the detail specifications this factor is considered in the so-called `life-time nomograms' (`Multiplier of useful life' graph) as a ratio between actual ripple current (IA) and rated ripple current (IR), drawn on the vertical axis. The heat generation depends on frequency and waveform of the alternating current. The maximum RMS value of this alternating current, which is permitted to pass through the capacitor during its entire specified useful life (at defined frequency and defined ambient temperature), is called rated ripple current (IR). Care should be taken to ensure that the actual ripple current remains inside the graph at any time of the entire useful life. If this cannot be realized, it is more appropriate to choose a capacitor with a higher rated voltage or higher capacitance, than originally required by the application. The rated ripple current is specified in the relevant detail specifications at 100 or 120 Hz (in special cases at 100 kHz) and at upper category temperature. The internal losses and the resultant ripple current capability of electrolytic capacitors are frequency dependent. Therefore, a relevant frequency conversion table (`Multiplier of ripple current as a function of frequency') is stated in the detail specifications. Usually the rated ripple current will cause a temperature increase of the capacitor's surface of approximately 3 or 5 K (dependent on series) compared with ambient temperature. A further temperature increase of 3 or 5 K will be found in the core of the capacitor. 1996 Dec 03 T x A x --------------------------ESR 8 Philips Components Electrolytic Capacitors General Introduction After these periods, the leakage current for acceptance test shall not exceed twice the specified IL5 requirement. CALCULATION OF THE APPLICABLE RMS RIPPLE CURRENT Non-sinusoidal ripple currents (if not accessible by direct measurement) have to be analyzed into a number of sinusoidal ripple currents by means of Fourier-analysis; the vectorial sum of the currents thus found may not exceed the applicable ripple current. To ensure good solderability and quality of taping, for all types and prior to mounting, the storage time shall not exceed 2-3 years. This means for example: 2 years storage time between manufacture and arrival at the customer, plus 1 year in customer storage. For some frequently occurring waveforms, approximation formulae are stated in Fig.11 for calculating the corresponding RMS value. OPERATIONAL CONDITIONS Charge-discharge proof handbook, halfpage WAVE FORM A t0 This term means the capability of capacitors to withstand frequent switching operations without significant change of capacitance. RMS VALUE Philips Al-electrolytic capacitors are charge-discharge proof in accordance with "IEC 384-4" and "CECC 30300 subclause 4.20": unless otherwise specified, 106 switching operations (RC = 0.1 s) shall not cause a capacitance change of more than 10%. t0 t A T T A t1 t2 t1 t A Non-frequent charging and discharging, without a series resistor, will not damage the capacitor. t2 3T If a capacitor is charged and discharged continuously several times per minute, the charge and discharge currents have to be considered as ripple currents flowing through the capacitor. The RMS value of these currents should be determined and the resultant value must not exceed the applicable limit. T A t2 t1 t2 3 t1 2 t2 t A 3T T Endurance test A t0 In "IEC 384-4" or "CECC 30300" the criteria for the acceptable drift of electrical parameters after the endurance test at UR and upper category temperature are defined. t0 t A 2T T Test duration and conditions per series are stated in the relevant detail specification. CCA416 Fig.11 Approximation formulae for RMS values of non-sinusoidal ripple currents. The endurance test does not provide information about the useful life of a capacitor, as no failure percentage is defined for this investigation. STORAGE Useful life No pre-condition will be necessary for Philips electrolytic capacitors, when stored under standard atmospheric conditions ("IEC 68-1, clause 5.3.1") for the following periods of time: Useful life (other names: load life, life time or typical life time) is that period of time, during which a given failure percentage may occur, under well defined conditions and requirements. Useful life data are usually calculated with a confidence level of 60%. 2 to 3 years for non-solid 85 C types 4 years for non-solid 105 C types 10 years for non-solid 125 C types 20 years for solid types. 1996 Dec 03 9 Philips Components Electrolytic Capacitors General Introduction High quality of materials and controlled manufacturing processes provided, the useful life of non-solid electrolytic capacitors is solely determined by evaporation of electrolyte through the sealing. decrease; this principle is derived from the well known law of Arrhenius about acceleration of reaction processes. Figure 12 shows the principal electrical consequences of this electrolyte loss: increasing impedance and decreasing capacitance at the end of useful life, for different non-solid (general purpose, long life and 125 C types) and solid (SAL-) electrolytic capacitors. The exact temperature dependence of useful life for a particular range is given in the corresponding detail specification in the `life-time nomogram' (`Multiplier of useful life' graph in the detail specifications). Detailed performance requirements, on which the definition `useful life' is based, are also stated in the relevant detail specifications. The influence of temperature on useful life is indicated by the so-called `10 K-rule' under the horizontal axis of the graph. The `10 K-rule' means approximately, that double the life time can be expected per 10 K temperature Exceeding those requirements shall not necessarily induce a malfunction of the equipment involved. The performance requirements offer advice on the choice of components and design of the circuitry. typ. useful life of general purpose types handbook, full pagewidth C/C 0 typ. useful life of long - life types typ. useful life of 125 oC - types (extra long - life types) CCA417 SAL - capacitors 100 (%) 125 oC types LL - types GP - types Z/Z D (%) GP - types LL - types 125 oC types SAL - capacitors 100 10K - rule 2000 h/85 oC 4000 h/75 oC 8000 h/65 o C 8000 h/85 oC 16000 h/75 oC 32000 h/65 oC 30000 h/85 oC 60000 h/75 oC 120000 h/65 oC 5 years / 40 oC 20 years / 40 o C 50 years / 40 oC life time at specified ambient temperature C0 = initial value of capacitance. ZD = specified limit of impedance. Fig.12 Principal trend of electrical parameters during useful life of different electrolytic capacitors. 1996 Dec 03 10 Philips Components Electrolytic Capacitors General Introduction CALCULATION OF USEFUL LIFE BY MEANS OF `LIFE-TIME NOMOGRAMS' At the intersection of these two operational conditions the appropriate multiplier (correction factor) for useful life can be read. The useful life under certain conditions shall be calculated by multiplying (or dividing respectively) the specified useful life, with the resultant correction factor. Based on the Arrhenius law and on experience for some decades, a nomogram is specified in the detail specification for each range, where the influence of ambient temperature and ripple current on the expected useful life is shown. Ripple currents at other frequencies than specified must be corrected using the frequency conversion tables in the relevant detail specification. The useful life determined by this procedure is normally valid for applications without forced cooling. Under certain conditions and with additional cooling, the useful life may be considerably extended. The ratio of ripple current (IA/IR) is plotted on the vertical axis and the ambient temperature (Tamb) on the horizontal. handbook, full pagewidth MBC579 I A 3.3 Axial and radial 85 oC - types. I A = actual ripple current at specified conditions. IR = rated ripple current, multiplied with the frequency correction factor (see relevant tables in the detail specifications). I R 3.2 3.1 3.0 2.8 2.6 2.4 lifetime multiplier 2.2 0 1. 5 1. 2.0 0 2. 0 3. 1.8 0 4. 0 6. 1.6 15 20 30 50 70 1.2 1.0 0.8 0.5 0.0 10 1.4 40 50 60 70 80 90 100 Tamb ( oC) Axial and radial 85 C types. Fig.13 Typical example of a life-time nomogram: useful life as a function of ambient temperature and ripple current load. 1996 Dec 03 11 Philips Components Electrolytic Capacitors handbook, full pagewidth IA 3.8 IR 3.7 General Introduction MBC580 Axial and radial 105 oC - types. I A = actual ripple current at specified conditions. IR = rated ripple current, multiplied with the frequency correction factor (see relevant tables in the detail specifications). 3.6 3.5 3.4 3.3 3.2 3.1 3.0 2.8 lifetime multiplier 2.6 1. 0 2.4 5 1. 0 2. 2.2 0 3. 0 4. 2.0 0 6. 0 8. 1.8 12 1.6 20 60 0 10 0 15 0 20 1.2 1.0 0.8 0.5 0.0 30 1.4 40 50 60 70 80 90 100 110 Tamb ( oC) Axial and radial 105 C types. Fig.14 Typical example of a life-time nomogram: useful life as a function of ambient temperature and ripple current load. 1996 Dec 03 12 Philips Components Electrolytic Capacitors General Introduction EXAMPLES FOR THE USE OF `LIFE-TIME NOMOGRAMS' Solution: Example 1 The mentioned life-times shall be converted to specified 85 C or 105 C life-times, i.e. they have to be divided through the correction factors found at the intersection of the respective operational conditions (see Table 4). Temperature in (operating) equipment is 45 C. Ripple current load is exactly the rated value (thus: IA/IR = 1). The required life-time can be fulfilled by types with a specified useful life of: Which useful life can be expected (without pause and storage times): 1. >2970 hours at 85 C i.e. a 3000 hours/85 C type, or 1. for a capacitor with a specified useful life of 2000 hours at 85 C? 2. >935 hours at 105 C i.e. a 1000 hours/105 C type. 2. for a capacitor with a specified useful life of 2000 hours at 105 C? Example 3 Which internal temperature may occur in the equipment, if the actual ripple current at 10 kHz is 3 times higher than specified for a 16 V-type and the load limit may not be exceeded? Solution: The corresponding life-time multiplier may be found at the intersection between the vertical `45 C'-line and the horizontal `1'-line. For the 85 C type this is `30' (see Fig.13) and for the 105 C type it is `90' (see Fig.14). Solution: 1. for 85 C type: 30 x 2000 hours = 60000 hours or about 7 years The ripple current must first be converted from 10 kHz to 100 Hz by using the conversion table (see typical example, Table 3). This shows that the conversion factor for a 16 V-type is 1.2. 2. for 105 C type: 90 x 2000 hours = 180000 hours or about 20 years. IA/IR = 3 at 10 kHz and must be divided by 1.2, resulting in IA/IR = 2.5 at 100 Hz. Example 2 The load limit is defined by the diagonal line `multiplier 1' in the relevant nomogram. Resulting useful life is thus: Which life time requirement has to be fulfilled by the capacitors, if the equipment life shall be 10 years (approx. 100000 hours), consisting of 1000 hours at 75 C + 9000 hours at 65 C + 90000 hours at 40 C? No ripple current applied (thus: IA/IR = 0). This means here: the vertical line on the intersection of IA/IR = 2.5 and the multiplier 1-line shows the maximum permitted internal temperature: 1. for 85 C types this is max. 59 C 2. for 105 C types this is max. 79 C. The corresponding life-time in this case is equal to the specified useful life. Table 3 Typical example of a frequency conversion table (IR/IRO) as a function of frequency; IRO = ripple current at 100 Hz FREQUENCY (Hz) IR MULTIPLIER UR = 6.3 to 25 V UR = 35 and 40 V UR = 50 and 63 V 50 0.95 0.85 0.80 100 1.00 1.00 1.00 300 1.07 1.20 1.25 1000 1.12 1.30 1.40 3000 1.15 1.35 1.50 10000 1.20 1.40 1.60 1996 Dec 03 13 Philips Components Electrolytic Capacitors Table 4 General Introduction Life-time calculation in "Example 2" LIFE CONDITIONS 1000 hours at 75 C 85 C TYPES (see Fig.13) 105 C TYPES (see Fig.14) 1000/2.9 = 345 hours 1000/8 = 125 hours 9000 hours at 65 C 9000/6 = 1500 hours 9000/20 = 450 hours 90000 hours at 40 C 90000/80 = 1125 hours 90000/250 = 360 hours sum for 85 C = 2970 hours sum for 105 C = 935 hours FAILURE RATE () 1 MTBF = --- however, for an individual component it is not longer than the specified useful life. The failure rate is defined by the number of components failing within a unit of time, related to the total quantity of components observed: number of failures (statistical upper limit 60%) = ------------------------------------------------------------------------------------------------------------------------total number of components x duration or The failure rate () is generally expressed in so-called `fit' (failure in time) = 10-9/hours with an upper confidence level (UCL) of 60%. It is calculated from results of periodical tests in the quality laboratories or derived from field observations respectively. failure percentage (%) = ----------------------------------------------------------100 x duration Usually the failure rate during time shows the well known `bathtub' curve (see Fig.15). MBC547 handbook, full pagewidth failure rate factory customer () (a) (b) (c) time (t) a) Initial failure period (`infant mortality'). b) Random failure period (= useful life period). c) Wear-out failure period. Fig.15 Failure rate () as a function of time (`bathtub' curve). 1996 Dec 03 14 Philips Components Electrolytic Capacitors General Introduction There are 3 periods in a typical capacitor life cycle: Since the failure rate mainly depends on two stress factors (temperature and applied voltage), it is usually specified under reference conditions, which are: Tamb = 40 C and U = 0.5 UR. 1. Initial failure period, showing a rapidly decreasing failure rate. During production of Philips electrolytic capacitors, initial failures are removed after re-forming (which is a short burn-in); all capacitors shipped, have passed burn-in. For other operational conditions, has to be converted correspondingly with the aid of Figs 16 and 17, failure rates as a function of stress factors (T and U/UR) for non-solid and SAL electrolytic capacitors. 2. Random failure period, showing a low and constant failure rate. This period is identical with `useful life'. The sum total of all (drift and accident) failures during this period, related to the total number of observed capacitors, is called `failure percentage'. Both are specified in the detail specification of the relevant series. CLIMATIC CATEGORY For each capacitor range the climatic category in accordance with "IEC 68-1" is stated in the relevant detail specification. The climatic category consists of three digit groups; example given in Table 5. 3. Wear-out failure period, showing an increasing failure rate due to gradual deterioration. CCA418 4.102 U/UR = 1 0.9 0.8 handbook, 4 columns failure rate multiplying factor 0.7 0.6 0.5 0.4 0.3 102 0.2/0.1 10 1 10-2 0 20 40 60 80 100 120 140 Tamb (C) Fig.16 Conversion factors for failure rate () as a function of ambient temperature (Tamb) and voltage ratio (U/UR) for non-solid electrolytic capacitors. 1996 Dec 03 15 Philips Components Electrolytic Capacitors General Introduction CCA425 102 handbook, full pagewidth failure rate multiplying factor U/UR = 1 10 0.9 0.8 0.7 0.6 0.5 0.4 1 10-1 0.3 0.2/0.1 0 50 100 150 Tamb (C) Fig.17 Conversion factors for failure rate () as a function of ambient temperature (Tamb) and voltage ratio (U/UR) for SAL electrolytic capacitors. Table 5 Example of climatic categories Example: 40 / 085 / 56 lower category temperature (here: -40 C) 40 upper category temperature (here: +85 C) 085 56 1996 Dec 03 duration of test `damp heat, steady state' (here: 56 days) 16 Philips Components Electrolytic Capacitors Table 6 General Introduction Maximum humidity condition indication for the application class RELATIVE AIR HUMIDITY CODE LETTER YEARLY AVERAGE 30 DAYS PER YEAR OCCASIONALLY DEWING C 95% 100% 100% permitted D 80% 100% 90% permitted E 75% 95% 85% slightly/rarely F 75% 95% 85% not permitted allow sufficient air circulation and to prevent mutual radiation. APPLICATION CLASS Although the German standard "DIN 40040" has been withdrawn, it is still widely used in industrial specifications for the definition of climatic working conditions. The application class consists of 3 code letters which have the following meanings. Likewise, if axial or radial types are subject to high ripple load, they shall be mounted with sufficient distance (e.g. 10 mm) from each other for good convection. ELECTRICAL Code letter meanings 1st letter: lower category temperature F: -55 C; G: -40 C; H: -25 C 2nd letter: upper category temperature P: +85 C; M: +100 (+105) C; K: +125 C 3rd letter: maximum humidity conditions (see Table 6) Parallel connection Al-electrolytic capacitors may be connected in parallel, but for safety reasons, large sizes should be individually guarded against sudden energy discharge of the whole battery due to a defective specimen. With smaller batteries, this safeguarding is sufficiently ensured by current limiting resistors. MOUNTING Series connection Mounting position of non-solid Al-electrolytic capacitors Al-electrolytic capacitors may be connected in series, but when doing so it should be noted that the voltage distribution will be according to their leakage currents. This phenomenon may induce irregularities in voltage load and cause maximum ratings to be exceeded; this could have drastic consequences, especially with high voltage capacitors. Snap-in and printed wiring (PW) as well as solder lug (SL) power electrolytic capacitors, in addition to the larger case sizes of axial and radial types, are normally equipped with pressure relief in the aluminium case. These and all smaller case size types, may be mounted in any position. Screw-terminal power electrolytic capacitors have a pressure relief in the sealing disc. These types shall be mounted so that no emissions of electrolyte or vapour may reach either the conductors under voltage, or other parts of the printed circuit board. Vertical (pressure relief up) or horizontal (pressure relief on the upper side) mounting position is recommended. Series-connected electrolytic capacitors should therefore be, either supplied by galvanically separated voltage sources or the voltages shall be proportionally distributed by balancing resistors. The balancing resistors can be dimensioned in accordance with the following approximation formula: Rsym (in k) = 10000/CR (in F) Design rules for `capacitor batteries' MECHANICAL Combined series/parallel connection Philips power electrolytic capacitors are mainly used in power supply applications under high ripple current load. In these circumstances, the capacitors must be mounted with a distance of 15 mm from each other, in order to The above mentioned rules for both series and parallel connection are accordingly valid for any combination of these two cases. 1996 Dec 03 17 Philips Components Electrolytic Capacitors General Introduction MARKING Philips electrolytic capacitors are identified in accordance with "IEC" rules. When sufficient space is available, capacitors are marked with the following details: Rated capacitance in F (the `' sign represents the position of the decimal point) Rated voltage in V Tolerance on rated capacitance if necessary, as a letter code in accordance with "IEC 62", e.g. T for -10/+50% M for 20% K for 10% Q for -10/+30% A for tolerance according to detail specification Group number 3-digit part of the catalogue number, e.g. 036 for RSP series Name of manufacturer PHILIPS or PH or P Date code abbreviation in 2 digits (("IEC 62") , e.g. 1st digit 2nd digit C = 1992 1 = January D = 1993 2 E = 1994 F = 1995 9 = September H = 1996 O = October J = 1997 N = November K = 1998 D = December = February ... example: F5 = produced in 1995, May production date may also be stated as year/week code example: 9525 = produced in 1995, 25th week Date code may also be stamped in the case. Factory code indicating the factory of origin Polarity identification strip, band or negative symbol ("-" sign) to indicate the negative terminal and/or a "+" sign to identify the positive terminal. 1996 Dec 03 18