R Digital Temperature Controllers E5EN Compact, Intelligent Temperature Controller H Reduced panel depth of only 78 mm H Accepts thermocouple, platinum RTD, non-contact temperature sensor, and analog temperature inputs H Auto-tuning and self-tuning available; functions can be used simultaneously H Heating or heating/cooling control H Event input option allows multiple set point selection and Run/Stop function H Water-resistant construction (NEMA 4X, uC equivalent to IP66) H Conforms to UL, CSA, and IEC safety standards as well as CE marking H 3-year warranty Ordering Information J TEMPERATURE CONTROLLERS Optional communications and event input boards are shown on the following page. Size 1/8 DIN 48(W) x 96(H) x 78(D) mm Heater burnout alarm Part number Thermocouple input Platinum RTD input No E5EN-R3MTC-500 AC100-240 E5EN-R3MP-500 AC100-240 Yes E5EN-R3HMTC-500 AC100-240 E5EN-R3HMP-500 AC100-240 Voltage (for driving SSR) No E5EN-Q3MTC-500 AC100-240 E5EN-Q3MP-500 AC100-240 Yes E5EN-Q3HMTC-500 AC100-240 E5EN-Q3HMP-500 AC100-240 Current No E5EN-C3MTC-500 AC100-240 E5EN-C3MP-500 AC100-240 Relay No E5EN-R3MTC-500 AC/DC24 E5EN-R3MP-500 AC/DC24 Yes E5EN-R3HMTC-500 AC/DC24 E5EN-R3HMP-500 AC/DC24 Voltage (for driving SSR) No E5EN-Q3MTC-500 AC/DC24 E5EN-Q3MP-500 AC/DC24 Yes E5EN-Q3HMTC-500 AC/DC24 E5EN-Q3HMP-500 AC/DC24 Current No E5EN-C3MTC-500 AC/DC24 E5EN-C3MP-500 AC/DC24 Power supply voltage Alarm points Output 100 to 240 VAC 3 Relay 24 V AC/DC 3 Note: 1. When the heating and cooling function is used, the number of alarm outputs will be reduced to 2. 2. The heating and cooling function and the heater burnout alarm will disable one of the alarm outputs for each function used. 53 E5EN E5EN J ACCESSORIES (ORDER SEPARATELY) Description Specifications Part number Computer communications boards RS-232C E53-AK01 RS-485 E53-AK03 Event input board For remote set point and Run/Stop functionality E53-AKB Current transformer; order only if using heater burnout alarm function 50 A load, 5.8 mm hole dia. E54-CT1 120 A load, 12 mm hole dia. E54-CT3 Terminal cover (supplied with controller) Provides finger protection from terminals (VDE0106 part 100) E53-COV11 Software For setup and monitoring; requires optional computer communications board SYS-CONFIG V2.0 J INPUT RANGES Input type Platinum resistance thermometer Name 1800 1700 1600 1500 1400 1300 1200 1100 1000 900 800 700 600 500 400 300 200 100 0 -100 -200 Set value Pt100 JPt100 Note: Lightly shaded ranges indicate default settings. 850 500.0 -200 -199.9 0 1 500.0 100.0 100.0 0.0 0.0 -199.9 2 3 4 Input type Name 1800 1700 1600 1500 1400 1300 1200 1100 1000 900 800 700 600 500 400 300 200 100 0 -100 -200 K J T E U N R 1700 S B K60 to 120C Analog input K115 to K160 to 165C 260C 0 to 50 mV Usable in the following ranges by scaling: -1999 to 9999 or -199.9 to 999.9 1700 1300 1300 850 850 600 500.0 400.0 400 400.0 400 400.0 260 120 165 0 0 0 0 12 13 14 15 70 100 -20.0 0 -100 0 1 2 -200 -199.9 4 17 3 Applicable standards by input type are as follows: K, J, T, E, N, R, S, B: JIS C1602-1995 L: Fe-CuNi, DIN 43710-1985 U: Cu-CuNi, DIN 43710-1985 JPt100: JIS C1604-1989, JIS C1606-1989 Pt100: JIS C1604-1997, IEC751 0 0 9 10 -100 -200 54 L K10 to 70C 1800 -20.0 Set value ES1A Non-contact Temperature Sensor Thermocouple -200 5 6 7 -199.9 -200 18 8 11 16 E5EN E5EN Specifications J RATINGS Supply voltage 100 to 240 VAC, 50/60 Hz Operating voltage range 85% to 110% of rated supply voltage Power consumption 9 VA Sensor input Thermocouple: K, J, T, E, L, U, N, R, S, B Platinum resistance thermometer: Pt100, JPt100 Non-contact temperature sensor: 10 to 70_C, 60 to 120_C, 115 to 165_C, 160 to 260_C Voltage input: 0 to 50 mV Control output 24 VAC, 50/60 Hz/24 VDC 5 VA/4 W Relay output SPST-NO, 250 VAC, 5 A (resistive load), electrical life: 100,000 operations Voltage output 12 VDC +15%/-20% (PNP), max. load current: 40 mA, with short-circuit protection circuit Current output 4 to 20 mA DC, load: 600 max., resolution: approx. 2,600 Alarm output SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations Control method PID or ON/OFF control Setting method Digital setting using front panel keys Indication method 7-segment digital display and single-lighting indicator Character height: PV: 14.0 mm; SV: 9.5 mm Ambient operating temperature -10_C to 55_C (14F to 131F) with no condensation or icing Storage temperature -25_C to 65_C (-13F to 149F) with no condensation or icing Ambient humidity 25% to 85% RH J CHARACTERISTICS Indication accuracy Thermocouple: 0.5% of indicated value or 1_C, whichever greater, 1 digit max. (See Note) Platinum resistance thermometer: 0.5% of indicated value or 1_C, whichever greater, 1 digit max. Analog input: 0.5% FS1 digit max. CT input: 5% FS1 digit max. Hysteresis 0.1 to 999.9 EU (in units of 0.1 EU) Proportional band (P) 0.1 to 999.9 EU (in units of 0.1 EU) Integral time (I) 0 to 3999 s (in units of 1 s) Derivative time (D) 0 to 3999 s (in units of 1 s) Control period 1 to 99 s (in units of 1 s) Manual reset value 0.0% to 100.0% (in units of 0.1%) Alarm setting range -1999 to 9999 (decimal point position depends on input type) Sampling period 500 ms Insulation resistance 20 M min. at 500 VDC Dielectric strength 2000 VAC, 50 or 60 Hz for 1 min between different charging terminals Vibration resistance 10 to 55 Hz, 10 m/s2 for 2 hours each in X, Y and Z directions Shock resistance 300 m/s2, 3 times each in 3 axes, 6 directions (relay: 100 m/s2) Weight Approx. 310 g; mounting bracket: Approx. 100 g Protective structure Front panel: NEMA 4X for indoor use (equivalent to IP66), rear case: IP20, terminals: IP00 Memory protection EEPROM non-volatile memory (number of writes: 100,000) Note: The indication of K thermocouples in the -200 to 1300C range, and T and N thermocouples at a temperature of -100C or less, and U and L thermocouples at any temperature is 2C1 digit maximum. The indication of B thermocouples at a temperature of 400C or less is unrestricted. The indication of R and S thermocouples at a temperature of 200C or less is 3C1 digit maximum. (This table continues on the next page.) 55 E5EN E5EN Specifications Table - continued from previous page EMC Emission Enclosure: Emission AC Mains: Immunity ESD: Immunity RF-interference: Immunity Conducted Disturbance: Immunity Burst: Approved standards EN55011 Group 1 class A EN55011 Group 1 class A EN61000-4-2: 4 kV contact discharge (level 2) 8 kV air discharge (level 3) ENV50140: 10 V/m (amplitude modulated, 80 MHz to 1 GHz) (level 3) 10 V/m (pulse modulated, 900 MHz) ENV50141: 10 V (0.15 to 80 MHz) (level 3) EN61000-4-4: 2 kV power-line (level 3) 2 kV I/O signal-line (level 4) UL3121-1, CSA22.2 No. 14, E.B.1402C Conforms to EN50081-2, EN50082-2, EN61010-1 (IEC61010-1) Conforms to VDE0106/part 100 (Finger Protection) when the terminal cover is mounted. J COMMUNICATIONS SPECIFICATIONS Transmission path connection Multiple points Communications method (See Note 1) RS-485 (two-wire, half duplex)/RS-232C Synchronization method Start-stop synchronization Baud rate 1,200/2,400/4,800/9,600/19,200 bps Transmission code ASCII Data bit length (See Note 2) 7 or 8 bits Stop bit length (See Note 2) 1 or 2 bits Error detection Vertical parity (none, even, odd) Frame check sequence (FCS): with SYSMAC WAY Block check character (BCC): with CompoWay/F Flow control Not available Interface (See Note 1) RS-485/RS-232C Retry function Not available Communications buffer 40 bytes Note: 1. RS-232C communications are only supported for the E5AN and E5EN models. 2. The baud rate, data bit length, stop bit length, or vertical parity can be individually set using the communications setting level. J CURRENT TRANSFORMER RATINGS Part number E54-CT1 E54-CT3 Max. continuous heater current 50 amps 120 amps Dielectric strength 1,000 VAC (for 1 min) Vibration resistance 50 Hz, 98 m/s2 (10G) Weight Approx. 11.5 g Approx. 50 g Accessories -- Armature: 2; Plug: 2 J HEATER BURNOUT ALARM Max. heater current Single-phase 50 A VAC (See Note 1) Heater current value display accuracy 5% FS1 digit max. Heater burnout alarm setting range 0.1 to 49.9 A (in units of 0.1 A) (See Note 2) Min. detection ON time 190 ms (See Note 3.) Note: 1. Use the K2CU-FjjA-jGS (with gate input terminals) for the detection of three-phase heater burnout. 2. The heater burnout alarm is always OFF if the alarm is set to 0.0 A and always ON if the alarm is set to 50.0 A. 3. No heater burnout detection or heater current value measurement is possible if the control output (heat) is ON for less than 190 ms. 56 E5EN E5EN Nomenclature Operation indicators Temperature unit No.1 display No.2 display Operation indicators Mode key Up key Level key Down key Dimensions Unit: mm (inch) 11.5 (0.45) 99.4 (3.91) 78 (3.07) 48 (1.89) 112 (4.41) 96 (3.78) 93.3 (3.67) Panel Cutouts Mounted Separately +0.8 92 0 (3.62) Group Mounted +1.0 48 number of units - 3.5 0 (1.89 number of units - 0.14) +0.8 92 0 (3.62) 120 (4.72) min. +0.8 0 92 (3.62) Group mounting does not allow waterproofing. * Recommended panel thickness is 1 to 8 mm (0.04 to 0.31 inch). * Group mounting is not possible in the vertical direction. (Maintain the specified mounting space between Controllers when they are group mounted.) * To mount the E5EN so that it is waterproof, apply the waterproof packing to the E5EN. * When two or more E5ENs are mounted, make sure that the surrounding temperature does not exceed the allowable operating temperature range in the specifications. 57 E5EN E5EN J CURRENT TRANSFORMER (SOLD SEPARATELY) E54-CT1 E54-CT3 2.36 (0.09) dia. 2.8 (0.11) dia. 21 (0.83) 30 (1.18) 12 dia. 5.8 (0.23) dia. 15 9 (0.35) 7.5 (0.30) 25 (0.98) 40 (1.57) x 40 (1.57) 10.5 (0.41) 3 40 (1.57) Two, M3 (depth: 4) Two, 3.5 dia. 15 (0.59) 10 (0.39) 30 (1.18) 30 (1.18) J TERMINAL COVER E53-COV11 13 (0.51) 6.5 (0.26) dia. 92.3 (3.63) 6.5 (0.26) 10.5 (0.41) 8 (0.31) Wiring Terminals The voltage output (control output) is not electrically isolated from the internal circuits. When using a grounded thermocouple, do not connect the control output terminals to ground. If the control output terminals are connected to the ground, errors will occur in the measured temperature values as a result of leakage current. Standard insulation is applied to the power supply I/O sections. If reinforced insulation is required, connect the input and output terminals to a device without any exposed current-carrying parts or to a device with standard insulation suitable for the maximum operating voltage of the power supply I/O section. Event input Contact inputs Current output Voltage output Relay output Non-contact input Input power supply Control output 1 Heater burnout detection input Alarm output ALM3/Control output 2 Alarm output ALM2 ALM1/Heater burnout 58 Analog input E5EN E5EN R OMRON ELECTRONICS, INC. OMRON CANADA, INC. One East Commerce Drive Schaumburg, IL 60173 885 Milner Avenue Scarborough, Ontario M1B 5V8 1-800-55-OMRON 416-286-6465 Cat. No. GCTC13 8/00 Specifications subject to change without notice. Printed in U.S.A.