01/11/07
www.irf.com 1
ASA28XXD SERIES
Description
Up To 5.0W Output Power
±5V, ±12V, ±15V Outputs
High Reliability
Wide Input Voltage Range -16V To 40V
Indefinite Short Circuit and Overload Protection
Popular Industry Standard Pin-Out
Military Screening
Parallel Seam Welded Package
No External Capacitors Required
Input Voltage Surge Protected to MIL-STD-704
Under Voltage Lockout
Standard Microcircuit Drawings Available
Features
28V Input, Dual Output
The ASA28XXD Series of DC/DC converters are high
reliability thick film hybrid converters that use flyback
topology operating at a nominal frequency of 550KHz.
High input to output isolation is achieved through the
use of transformers in the flyback power and feed back
circuits.
The advanced feedback design provides fast loop
response for superior line and load transient
characteristics and offers greater reliability than devices
incorporating optical feedback circuits.
This device is designed to meet MIL-STD-704 input
requirements offering full performance over a 16V to
40V input range. Output Power of up to 5W is available
for either balanced or unbalanced loads.
Connecting the inhibit pin (pin 5) to the input common
(pin 7) will cause the converter to shut down. It is
recommended that the inhibit pin be driven by an open
collector device capable of sinking at least 400µA. The
open circuit voltage of the inhibit pin is 11.5 ± 0.5V.
Manufactured in a facility fully qualified to MIL-PRF-
38534, these converters are fabricated utilizing DSCC
qualified processes. For available screening options,
refer to device screening table in the data sheet.
Variations in electrical, mechanical and screening can
be accommodated. Extensive computer simulation
using complex modeling enables rapid design
modification to be provided. Contact IR Santa Clara
with specific requirements.
HYBRID-HIGH RELIABILITY
DC/DC CONVERTER
ASA
PD-94540A
2www.irf.com
ASA28XXD Series
Specifications
For Notes to Specifications, refer to page 3
ASA2805D/XX
ASA2812D/XX
ASA2815D/XX
TEST
Conditions
-55° TC +125°C
VIN = 28V dc ±5% CL = 0
unless otherwise sp ecified
Group A
Subgroups Min Max Min Max Min Max Unit
1 ±4.95 ±5.05 ±11.88 ±12.12 ±14.85 ±15.15
Output voltage IOUT = 0 2, 3 ±4.90 ±5.10 ±11.76 ±12.24 ±14.70 ±15.30
V
Output current 1, 2 V
IN = 16, 28, and 40 V dc
either output
1, 2, 3 200 1000 84 333 67 267 mA
Output ripple voltage 3, 4 V
IN = 16, 28 and 40 V dc 1, 2, 3 470 200 290
mV PP
Line regulation 4 V
IN = 16, 28, and 40 V dc
IOUT = 0, 50%, 100% IMAX
1, 2, 3 50 50 50 mV
Load regulation 4 V
IN = 16, 28, and 40 V dc
IOUT = 0, 50%, 100% IMAX
1, 2, 3 50 50 50 mV
Cross regulation 5 20% to 80% load change 1, 2, 3 15 8.0 8.0 %
IOUT = 0
Pin 5 connected to pin 7
12 12 12
Input current
IOUT = 0 Pin5 open
1, 2, 3
60
60
60
mA
Input ripple current 3, 4 I
OUT = IMAX 1, 2, 3 100 100 100
mA PP
1, 3 70 71 71
Efficiency 4 I
OUT = IMAX
2 66
68
68
%
Isolation Input to output or any pin to
case (except pin 8) at 500 V
dc, Tc = +25° C
1 100 100 100 M
Capacitive load 6, 7 No effect on dc performance,
total for both outputs 4 200 200 200
µF
Overload 8 4.0 4.0 4.0
Power dissipation load fault
Short circuit
1, 2, 3
2.0
2.0
2.0
W
Switching frequency 4 I
OUT = IMAX 4, 5, 6 500 600 500 600 500 600 KHz
IOUT = 50% 100% IMAX -400 +400 -400 +400 -400 +400
Output response to step
transient load changes 4, 9
IOUT = 0 50% IMAX
4, 5, 6
-800 +800 -800 +800 -800 +800
mV pk
IOUT = 50% 100% IMAX 100 100 100
Recovery time, step
transient load changes
4, 9, 10 IOUT = 0 50% IMAX
4, 5, 6
2000 2000 2000
µs
Output response transient
step line changes 4, 7, 11 VIN =16 40Vdc,IOUT= IMAX 4, 5, 6 -750 +750 - 750 +750 -750 +750 mV pk
Recovery time transient step
line changes
4, 7, 10, 11
VIN=16 40Vdc, IOUT= IMAX 4, 5, 6 1200 1200 1200
µs
Turn on overshoot 4 I
OUT = 0 and IMAX 4, 5, 6 600 600 600 mV pk
Turn on delay 4, 12 I
OUT = 0 and IMAX 4, 5, 6 25 25 25 ms
Load fault recovery 7 4, 5, 6 25 25 25 ms
Input voltage -0.5V to +50VDC Continous, 80V, 100 msec
Power output Internally limited ( 6.5W typical )
Soldering temperature 300°C for 10 seconds
Operating case temperature -55°C to +125°C
Storage case temperature -65°C to +135°C
Absolute Maximum Ratings
www.irf.com 3
ASA28XXD Series
Notes to Specifications
1. Parameter guaranteed by line, load, and cross regulation tests.
2. Up to 80% of full power is available from either output provided the total output does not exceed 5W.
3. Bandwidth of DC to 20MHz is guaranteed by design. Tested for 20KHz to 2MHz.
4. Load current split equally between +VOUT and -VOUT.
5. 1.0W load on output under test, 1.0W to 4.0W load change on other output.
6. Capacitive load may be any value from 0 to the maximum limit without compromising DC performance. A capacitive load in excess
of the maximum limit will not disturb loop stability but may interfere with the operation of the load fault detection circuitry,
appearing as a short circuit during turn-on.
7. Parameter shall be tested as part of design characterization and after design or process changes. Thereafter, parameters shall
be guaranteed to the limits specified.
8. An overload is a condition with a load in excess of rated but less than that necessary to trigger the short circuit protection and is
the condition of maximum power dissipation.
9. Load step transition time between 2µs and 10µs.
10. Recovery time is measured from the initiation of the transient to where VOUT has returned to within ±1% of VOUT at 50% load.
11. Input step transition time between 2µs and 10µs.
12. Turn-on delay time measurements is for either a step application of power at the input or the removal of ground connection from
enable pin (pin 5) with power applied to the input.
Block Diagram
Controller
Error
Amplifier
1
2
8
6
7
5
Case
Output
Return
+Output
Inhibit
Input
Return
+Input
3
-Output
4www.irf.com
ASA28XXD Series
0.800
±.005
1.075
0.220
0.270
1.075
0.800
0.025 ± .003 Dia Pins
12345
687
Mechanical Outline
Pin Designation
Standard Microcircuit Drawing Equivalence Table
Standard Microcircuit IR Standard
Drawin
g
Number Part Number
5962-94649 ASA2815D
5962-95648 ASA2812D
Pin # Designation
1 + Output
2 Output Return
3 - Output
4NC
5 Inhibit
6 + Input
7 Input Return
8 Case Ground
www.irf.com 5
ASA28XXD Series
Part Numbering
WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, Tel: (310) 252-7105
IR SANTA CLARA: 2270 Martin Av., Santa Clara, California 95050, Tel: (408) 727-0500
Visit us at www.irf.com for sales contact information.
Data and specifications subject to change without notice. 01/2007
Notes:
Best commercial practice
Sample tests at low and high temperatures
-55°C to +105°C for AHE, ATO, ATW
Device Screening
Requirement MIL-STD-883 Method No Suffix ES HB CH
Temperature Range -2C to +85°C -5C to +125°C -5C to +125°C -55°C to +125°C
Element Evaluation MIL-PRF-38534 N/A N/A N/A Class H
Non-Destructive
Bond Pull
Internal Visual 2017 Yes Yes Yes
Temperature Cycle 1010 N/A Cond B Cond C Cond C
Constant Acceleration 2001, Y1 Axis N/A 500 Gs 3000 Gs 3000 Gs
PIND 2020 N/A N/A N/A N/A
Burn-In 1015 N/A 48 hrs@hi temp 160 hrs@12C 160 hrs@125°C
Final Electrical MIL-PRF-38534 25°C 25°C -55°C, +25°C, -55°C, +25°C,
( Group A ) & Specification +125°C +12C
PDA MIL-PRF-38534 N/A N/A N/A 10%
Seal, Fine and Gross 1014 Cond A Cond A, C Cond A, C Cond A, C
Radiographic 2012 N/A N/A N/A N/A
External Visual 2009 Yes Yes Yes
N/A N/A2023 N/A N/A
ASA 28 05 D /CH
Model
Input Voltage
28 = 28V
Output Voltage
05 = ±5V
12 = ±12V
15 = ±15V
Output
D = Dual
Screening Level
(Please refer to Screening Table)
No Suffix, ES, HB, CH