363
Selection
Guide
Amplier
Built-in
Power Supply
Built-in
Amplier-
separated
CX-400
CY-100
EX-10
EX-20
EX-30
EX-40
CX-440
EQ-30
EQ-500
MQ-W
RX-LS200
RX
RT-610
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN MACHINE
INTERFACES
ENERGY CONSUMPTION
VISUALIZATION
COMPONENTS
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
Related Information
Adjustable Range Reective Photoelectric Sensor
Amplier Built-in
Multi-voltage
EQ-500 SERIES
General terms and conditions ............. F-7
Glossary of terms / General precautions
.......
P.1455~ / P.1458~
Long range sensing capability to 2.5 m 8.202 ft
Stable sensing unaffected by color or material
Recognition
Long sensing range
An adjustable range to 2.5 m 8.202 ft allows plenty of
space for installation.
1 m 3.281 ft sensing range type also available. Adjust
the volume easily to suit your needs when using at close
range.
Hardly affected by background objects
Because the sensor doesn’t detect objects outside the
preset sensing eld by using the 2-segment photodiode
adjustable range system, it will not malfunction even if
someone walks behind the sensing object or machines
or conveyors are in the background.
Note: Please note that malfunction may occur when there are specular
objects or objects with a mirror-like surface in the background.
Impervious to variations color or angle
The optical system has been optimized. Since the
sensor is hardly inuenced at all by angles or the gloss
of objects compared to the previous model, it is possible
to detect both white objects and black objects at almost
a constant distance.
Convenient terminal block type
Cabling enabled
by way of a
terminal block
that eliminates
waste.
MOUNTING
Conduit connector
Terminal block
Sensor selection guide
.................. P.271~
Certified
(Multi-voltege type only)
China’s CCC mark ........................ P.1505
Conforming to Low Voltage
and EMC Directive
DC-voltage type conforms
to EMC directive only
An easy to set adjuster with indicator
Equipped with a 2-turn adjuster with indicator, making it
easy to set for short or long distances.
OPERABILITY
Adjuster
indicator
ON-delay timer
adjuster (Note)
OFF-delay timer
adjuster (Note)
Distance adjuster
(2-turn)
Note: For EQ-5□T only.
(
)
The difference in sensing range between white non-glossy
paper and gray non-glossy paper (lightness: 5) is approx 5%
when set at a distance of 2 m 6.562 ft.
Refer to p.368 “Mounting” of “PRECAUTIONS FOR PROPER
USE” section.
panasonic.net/id/pidsx/global
Adjustable Range Reective Photoelectric Sensor EQ-500 SERIES
364
Selection
Guide
Amplier
Built-in
Power Supply
Built-in
Amplier-
separated
CX-400
CY-100
EX-10
EX-20
EX-30
EX-40
CX-440
EQ-30
EQ-500
MQ-W
RX-LS200
RX
RT-610
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN MACHINE
INTERFACES
ENERGY CONSUMPTION
VISUALIZATION
COMPONENTS
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
APPLICATIONS
Level check within the hopper
The distance to the object can be set
to enable residual amount sensing in
the hopper regardless of color.
Conrmation of the passage of
packages on a conveyor belt
Can accurately detect packages even
if they vary in
size and color.
Equipped with both NPN and PNP outputs
EQ-51
We’ve added a DC-voltage type
with NPN and PNP transistor
outputs all in one sensor. Its
BGS / FGS function controls
any background effects for more
stable sensing.
VARIETIES
Multi-voltage
EQ-50
Because it can function with 24 to 240 V AC and 12 to
240 V DC, almost any power supply anywhere in the
world will do.
Convenient timer function models
Types with an ON-delay / OFF-delay timer available.
OFF-delay, e.g. useful when the response of the
connected device is slow, ON-delay, e.g. useful to detect
objects that take a long time to move.
BGS / FGS functions make even the most challenging settings possible!
FUNCTIONS
When object and background are separated
BGS (Background suppression) function
The sensor judges that an object is
present when light is received at position
A of the light-receiving element (2-segment
element).
This is useful if the object and background
are far apart.
Not affected if the background color changes
or someone passes behind the conveyor.
When object and background are close
together
When the object is glossy or uneven
FGS (Foreground suppression) function
The sensor judges that no object is present
when light is received at position B of the light
receiving element (2-segment element) (The
conveyor is detected). This function is useful
if the object and the background are close
together or if the object is glossy or uneven.
However, sensing is impossible if there is no
background (conveyor, etc.).
Setting distance
Light received at
element A
Element A
ObjectMoving object
in the back
Background
Element B
Light received at element
B or light not received
ONOFF
OFF in this condition only ON in all other conditions
Conveyor
A conveyor or other
background must be present.
Element A
Lens
Emitting
element
Object absent
OFF
Element B
Light received at element B
Conveyor Conveyor
Light is not received at
element B, so an object
is judged to be present
For glossy
object
Object present
ON ON
Setting
distance
Light received
at element A
Note: Refer to “BGS / FGS function (p.369)” of “PRECAUTIONS FOR PROPER USE” for operation of BGS / FGS function.
EQ-51
The BGS function is best suited for background not present
The FGS function is best suited for background present
• Operation: ON-delay, OFF-delay
• Timer period: 0.1 to 5 sec.
(individual setting possible)
365
Adjustable Range Reective Photoelectric Sensor EQ-500 SERIES
Selection
Guide
Amplier
Built-in
Power Supply
Built-in
Amplier-
separated
CX-400
CY-100
EX-10
EX-20
EX-30
EX-40
CX-440
EQ-30
EQ-500
MQ-W
RX-LS200
RX
RT-610
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
ORDER GUIDE
Type Appearance Sensing range Model No. Supply voltage Output Timer function
Multi-voltage
0.1 to 2.5 m
0.328 to 8.202 ft
EQ-501
24 to 240 V AC
±10 %
or
12 to 240 V DC
±10 %
Relay contact 1a
With timer
EQ-501T ON-delay / OFF-delay timer
(Timer period: 0.1 to 5 sec.)
0.1 to 1.0 m
0.328 to 3.281 ft
EQ-502
With timer
EQ-502T ON-delay / OFF-delay timer
(Timer period: 0.1 to 5 sec.)
DC-voltage
0.1 to 2.5 m
0.328 to 8.202 ft
EQ-511
12 to 24 V DC
±10 %
NPN
open-collector
transistor
PNP
open-collector
transistor
Equipped with
2 outputs
With timer
EQ-511T ON-delay / OFF-delay timer
(Timer period: 0.1 to 5 sec.)
0.1 to 1.0 m
0.328 to 3.281 ft
EQ-512
With timer
EQ-512T ON-delay / OFF-delay timer
(Timer period: 0.1 to 5 sec.)
OPTION
Designation Model No. Description
Sensor mounting
bracket MS-EQ5-01 Foot / back angled mounting bracket
Two M5 (length 30 mm 1.181 in)
screws with washers and two
nuts are attached.
Sensor mounting bracket
MS-EQ5-01
Little affected by contamination on lens
Even if the lens surface gets
somewhat dirty from dust
particles, there is very little
change in the operation eld,
by usage adjustable range
system.
ENVIRONMENTAL RESISTANCE
Waterproof
IP67 protection
permits use in
environments where
water may splash.
Note: Sensor may detect a
water drop itself, if it
is exposed to water
splashes during
operation.
Adjustable Range Reective Photoelectric Sensor EQ-500 SERIES
366
Selection
Guide
Amplier
Built-in
Power Supply
Built-in
Amplier-
separated
CX-400
CY-100
EX-10
EX-20
EX-30
EX-40
CX-440
EQ-30
EQ-500
MQ-W
RX-LS200
RX
RT-610
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Type Multi-voltage DC-voltage
With timer With timer With timer With timer
Item Model No. EQ-501 EQ-501T EQ-502 EQ-502T EQ-511 EQ-511T EQ-512 EQ-512T
Adjustable range (Note 2,3) 0.2 to 2.5 m 0.656 to 8.202 ft 0.2 to 1.0 m 0.656 to 3.281 ft 0.2 to 2.5 m 0.656 to 8.202 ft 0.2 to 1.0 m 0.656 to 3.281 ft
Sensing range (at max. setting distance) (Note 3)
0.1 to 2.5 m 0.328 to 8.202 ft 0.1 to 1.0 m 0.328 to 3.281 ft 0.1 to 2.5 m 0.328 to 8.202 ft 0.1 to 1.0 m 0.328 to 3.281 ft
Hysteresis (Note 3) 10 % or less of operation distance
Supply voltage 24 to 240 V AC ±10 % or 12 to 240 V DC ±10 %
Ripple P-P 10 % or less 12 to 24 V DC ±10 % Ripple P-P 10 % or less
Power / Current consumption
AC: 4 VA or less
DC: 3 W or less
AC: 5 VA or less
DC: 4 W or less
AC: 4 VA or less
DC: 3 W or less
AC: 5 VA or less
DC: 4 W or less
45 mA or less
Output
Relay contact 1a
Switching capacity: 2 50 V AC 3 A (resistive load)
30 V DC 3 A (resistive load)
Electrical life: 100,000 or more switching operations
(switching frequency 1,200 operations/hour)
Mechanical life: 50 million or more switching operations
(switching frequency 18,000 operations/hour)
NPN open-collector transistor
Maximum sink current: 100 mA
Applied voltage: 30 V DC or less (between output and 0 V)
Residual voltage: 1 V or less (at 100 mA sink current)
0.4 V or less (at 16 mA sink current)
PNP open-collector transistor
Maximum source current: 100 mA
Applied voltage: 30 V DC or less (between output and +V)
Residual voltage: 1 V or less (at 100 mA source current)
0.4 V or less (at 16 mA source current)
Output operation Switchable either Detection-ON or Detection-OFF
Short-circuit protection
Incorporated
Response time
20 ms or less (For EQ-50□T depends on the setting timer period)
2 ms or less (For EQ-51□T depends on the setting timer period)
Operation indicator Orange LED (lights up when the output is ON)
Stability indicator Green LED (lights up under stable operating condition)
Distance adjuster 2-turn mechanical adjuster with indicator
Sensing mode
Switchable either BGS or FGS function
Timer function
Incorporated with
variable
(0.1 to 5 sec.)
ON-delay /
OFF-delay timer
Incorporated with
variable
(0.1 to 5 sec.)
ON-delay /
OFF-delay timer
Incorporated with
variable
(0.1 to 5 sec.)
ON-delay /
OFF-delay timer
Incorporated with
variable
(0.1 to 5 sec.)
ON-delay /
OFF-delay timer
Automatic interference prevention function
Incorporated (Note 4)
Environmental resistance
Protection IP67 (IEC)
Ambient temperature –20 to +55 °C –4 to +131 °F (No dew condensation or icing allowed), Storage: –30 to +70 °C –22 to +158 °F
Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH
Ambient illuminance Incandescent light: 3,000 ℓx at the light-receiving face
Voltage withstandability
2,000 V AC for one min. among supply terminals, non-supply
metal parts and relay contact output terminals, 1,000 V AC for
one min. between relay contacts
1,000 V AC for one min. between all supply terminals
connected together and enclosure
Insulation resistance
100 MΩ, or more, with 500 V DC megger among supply
terminals, non-supply metal parts and relay contact output
terminals as well as between relay contacts
20 MΩ, or more, with 250 V DC megger between all supply
terminals connected together and enclosure
Vibration resistance 10 to 55 Hz frequency, 1.5 mm 0.059 in amplitude in X, Y and Z directions for two hours each
Shock resistance 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions for three times each
Emitting element Infrared LED (Peak emission wavelength: 855 nm 0.034 mil, modulated)
Receiving element 2-segment photodiode
Material Enclosure: ABS, Front cover: Polycarbonate, Display cover: Polycarbonate
Connection method Screw-on terminal connection
Cable Suitable for round cable ø9 to ø11 mm ø0.354 to ø0.433 in
Cable length Total length up to 100 m 328.084 ft is possible with 0.3 mm2, or more, cabtyre cable.
Weight Net weight: 100 g approx. Net weight: 85 g approx.
Accessory Adjusting screwdriver: 1 pc.
Notes: 1) Where measurement conditions have not been specied precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F.
2) The adjustable range stands for the maximum sensing range which can be set with the distance adjuster. The sensor can also detect an object 0.1 m
0.328 ft, or more, away.
3) The adjustable range, sensing range and hysteresis are specied for white non-glossy paper (200 × 200 mm 7.874 × 7.874 in) as the object.
4) Note that the detection may be unstable depending on the mounting conditions or the sensing object. In the state that this product is mounted, be sure
to check the operation with the actual sensing object. Refer to “Automatic interference function (p.368)” of “PRECAUTIONS FOR PROPER USE” for
details.
SPECIFICATIONS
367
Adjustable Range Reective Photoelectric Sensor EQ-500 SERIES
Selection
Guide
Amplier
Built-in
Power Supply
Built-in
Amplier-
separated
CX-400
CY-100
EX-10
EX-20
EX-30
EX-40
CX-440
EQ-30
EQ-500
MQ-W
RX-LS200
RX
RT-610
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
I/O CIRCUIT AND WIRING DIAGRAMS
EQ-501(T) EQ-502(T)
I/O circuit diagram
Output relay
Sensor circuit
Multi-voltage
circuit
Relay contact output
(1a)
Terminal No.
Supply voltage
24 to 240 V AC ±10 %
or
12 to 240 V DC ±10 %
Internal circuit
4
3
2
1
4
3
2
1
I/O circuit diagram
EQ-511(T) EQ-512(T)
4
3
2
1
Terminal arrangement diagram
SENSING CHARACTERISTICS (TYPICAL)
EQ-501(T) EQ-511(T)
Sensing elds Correlation between material
(200 × 200 mm 7.874 × 7.874 in) and sensing range
Setting distance: 1 m 3.281 ft
20
0.787
10
0.394
010
0.394
20
0.787
0
0.5
1.640
1
3.281
200 × 200 mm
7.874 × 7.874 in
Non-glossy
paper
L
Sensor
Setting distance L (m ft)
White non-
glossy paper
Left Right
Center
Operating point ℓ (mm in)
Gray non-glossy paper
Lightness: 5
Setting distance: 2.5 m 8.202 ft
0
1
3.281
2
6.562
3
9.843
4
13.123
20
0.787
10
0.394
010
0.394
20
0.787
Sensor
L
Setting distance L (m ft)
200 × 200 mm
7.874 × 7.874 in
Non-glossy paper
Gray non-glossy paper
Lightness: 5
White non-
glossy paper
Left Right
Center
Operating point ℓ (mm in)
0
1
3.281
2.5
8.202
•••
•••
These bars indicate
the sensing range
with the respective
objects when the
distance adjuster is
set to a sensing range
of 2.5 m 8.202 ft / 1 m
3.281 ft long,
respectively, with
white non-glossy
paper.
2.5 m
8.202 ft
1 m
3.281 ft
White non-
glossy paper
Cardboard
Plywood
Black rubber
Gray non-grossy
paper (Lightness: 5)
Sensing range L (m ft)
Correlation between color
(200 × 200 mm 7.874 × 7.874 in non-glossy paper) and sensing range
Emitted beam
Correlation between sensing object size
and sensing range
0
1
3.281
2.5
8.202
•••
•••
2.5 m
8.202 ft
1 m
3.281 ft
These bars indicate
the sensing range with
the respective colors
when the distance
adjuster is set to a
sensing range of 2.5 m
8.202 ft / 1 m 3.281 ft
long, respectively, with
white non-glossy
paper.
The sensing range
also varies depending
on material.
White
Yellow
Orange
Red
Brown
Blue
Green
Gray
(Lightness: 8)
Gray
(Lightness: 5)
Sensing range L (m ft)
0
2
6.562
1.5
4.921
1
3.281
0.5
1.640
2.5
8.202
Distance L (m ft)
ø42 mm
ø1.654 in
ø26 mm
ø1.024 in
ø20 mm
ø0.787 in
ø56 mm
ø2.205 in
ø70 mm
ø2.756 in
White non-glossy paper
side length a (mm in)
Sensing range L (m ft)
L
Sensor
White
non-glossy paper
050
1.969 100
3.937 150
5.906 200
7.874
1
3.281
2.5
8.202
2
6.562
Setting distance: 2.5 m 8.202 ft
This curve shows
the characteristics
with the maximum
sensing range set
to 2.5 m 8.202 ft,
with white
non-glossy paper
(200 × 200 mm
7.874 × 7.874 in).
D
Tr1
12 to 24 V DC
±10 %
Sensor circuit
ZD1
Load
Load
Output (NPN)
0 V
+V
+
Tr2 ZD2
Output (PNP)
100 mA max.
100 mA max.
Internal circuit Users’ circuit
4
3
2
1
Terminal arrangement diagram
Symbols ... D: Reverse supply polarity protection diode
ZD1, ZD2: Surge absorption zener diode
Tr1: NPN output transistor
Tr2: PNP output transistor
Adjustable Range Reective Photoelectric Sensor EQ-500 SERIES
368
Selection
Guide
Amplier
Built-in
Power Supply
Built-in
Amplier-
separated
CX-400
CY-100
EX-10
EX-20
EX-30
EX-40
CX-440
EQ-30
EQ-500
MQ-W
RX-LS200
RX
RT-610
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
SENSING CHARACTERISTICS (TYPICAL)
EQ-502 (T) EQ-512 (T)
Sensing elds Correlation between material
(200 × 200 mm 7.874 × 7.874 in) and sensing range
Setting distance: 0.5 m 1.640 ft Setting distance: 1 m 3.281 ft
0
0.5
1.640
1
3.281
These bars indicate
the sensing range with
the respective objects
when the distance
adjuster is set to a
sensing range of 1 m
3.281 ft / 0.5 m 1.640 ft
long, respectively, with
white non-glossy
paper.
•••
•••
Sensing range L (m ft)
1 m
3.281 ft
0.5 m
1.640 ft
White non-
glossy paper
Cardboard
Plywood
Black rubber
Gray non-grossy
paper (Lightness: 5)
0
0
0.2
0.656
0.4
1.312
0.6
1.969
0.8
2.625
L
Gray non-glossy paper
Lightness: 5
20
0.787
10
0.394
10
0.394
20
0.787
200 × 200 mm
7.874 × 7.874 in
Non-glossy paper
Sensor
White non-
glossy paper
Left Right
Center
Operating point ℓ (mm in)
Setting distance L (m ft)
20 1001
02
0
0
0.5
1.640
1
3.281
L
Sensor
Gray non-glossy paper
Lightness: 5
020
0.787
10
0.394
10
0.394
20
0.787
200 × 200 mm
7.874 × 7.874 in
Non-glossy paper
White non-
glossy paper
Left Right
Center
Operating point ℓ (mm in)
Setting distance L (m ft)
Correlation between color (200 × 200 mm 7.874 × 7.874 in non-glossy paper) and sensing range
Emitted beam
Correlation between sensing object size and sensing range
These bars indicate
the sensing range with
the respective colors
when the distance
adjuster is set to a
sensing range of 1 m
3.281 ft / 0.5 m 1.640 ft
long, respectively, with
white non-glossy
paper.
The sensing range
also varies depending
on material.
0.5
1.640
1
3.281
•••
•••
Sensing range L (m ft)
White
Yellow
Orange
Red
Brown
Blue
Green
Gray
(Lightness: 8)
Gray
(Lightness: 5)
1 m
3.281 ft
0.5 m
1.640 ft
0
1
3.281
0.5
1.640
Distance L (m ft)
ø26 mm
ø1.024 in
ø20 mm
ø0.787 in
This curve shows the
characteristics with
the maximum
sensing range set to
1 m 3.281 ft, with
white non-glossy
paper
(200 × 200 mm
7.874 × 7.874 in).
0.5
1.640
1
3.281
White non-
glossy paper
Sensor
L
White non-glossy paper
side length a (mm in)
Sensing range L (m ft)
050
1.969 100
3.937 150
5.906 200
7.874
Setting distance: 1 m 3.281 ft
PRECAUTIONS FOR PROPER USE Refer to p.1458~ for general precautions.
M5 nut
M5 (length 30 mm 1.181 in)
screw with washers
Sensor
mounting
blacket
MS-EQ5-01
(Optional)
Mounting
The tightening torque
should be 0.8 N·m or less.
Care must be taken
regarding the sensor
mounting direction with
respect to the object’s
direction of movement.
Sensing object Sensing object
Do not make the sensor
detect an object in this
direction because it may
cause unstable operation.
Sensing object
When detecting a specular object (aluminum or copper foil,
etc.) or an object having a glossy surface or coating, please
note that there are cases when the object may not be detected
due to a change in angle, wrinkles on the object surface, etc.
If a specular body is present in the background, faulty operation may
be caused due to a small change in the angle of the background
body. In that case, install the sensor at an inclination and conrm the
operation with the actual sensing object.
When a specular body is present below the sensor, use the
sensor by tilting it slightly upwards to avoid faulty operation.
Specular
face Specular
face
Tilt
This product is not easily affected by the reected light
intensity since this sensor is the adjustable range reective
type. When the reected light intensity is remarkably low,
the sensing range may be affected. In that case, mount the
sensor, while checking light-up of the stable indicator (green).
The mounting screws of the terminal cover and display cover
should certainly be tightened to maintain water-resistance;
the tightening torque of the screws should be 0.3 to 0.5 N·m.
Automatic interference prevention function
When the sensors are mounted closely, use them in the
interference prevented area, as shown below.
L mm in
or more L mm in
or more
L mm in
or more
0 150
5.906
50
1.969
250
9.843
200
7.874
100
3.937
Mounting interval L (mm in)
1
3.281
2
6.562
3
9.843
Setting distance (m ft)
Interference
prevented area
Note that the detection may be unstable depending on
the mounting conditions or the sensing object to be used.
In the state that this product is mounted, be sure to check
the operation with the actual sensing object to be used.
1
3.281
2
6.562
3
9.843
06
0
2.362
20
0.787
80
3.15
40
1.575
Setting distance (m ft)
Mounting interval L (mm in)
Interference
prevented area
L mm in
or more
Never use this product as a sensing device
for personnel protection.
In case of using sensing devices for
personnel protection, use products which
meet laws and standards, such as OSHA,
ANSI or IEC etc., for personnel protection
applicable in each region or country.
Correct Correct Incorrect
Incorrect Correct
369
Adjustable Range Reective Photoelectric Sensor EQ-500 SERIES
Selection
Guide
Amplier
Built-in
Power Supply
Built-in
Amplier-
separated
CX-400
CY-100
EX-10
EX-20
EX-30
EX-40
CX-440
EQ-30
EQ-500
MQ-W
RX-LS200
RX
RT-610
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
BGS
L-ON
D-ON
FGS
L-ON
D-ON
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Setting distance
Non-detectable area
Detectable range
PRECAUTIONS FOR PROPER USE Refer to p.1458~ for general precautions.
Wiring Part description
Operation mode switch
BGS / FGS function (DC-voltage type only)
DC-voltage type sensor incorporates BGS / FGS function.
Select either the BGS or FGS function depending on the
positions of the background and sensing object.
BGS / FGS function is set with the operation mode
switch.
FGS function is used when the sensing object contacts
the background (conveyor, etc).
Depends on a selection of either BGS or FGS function,
the output operation changes as follows.
Check all wiring before applying power since incorrect
wiring may damage the internal circuit. Also, carefully
tighten the terminal screws so that the wires of adjacent
terminals do not touch.
The mounting hole for the terminal cover xing screws
inclines 70 degrees to the terminal cover, as shown in the
gure below.
To avoid damaging this product or screw, take care when
tightening or loosening a screw.
Notes: 1)
The operation mode switch of the DC-voltage type is the DIP switch.
Refer to ‘DC-voltage type’ of ‘Operation mode switch’ for details.
2) Incorporated on EQ-5□T only.
Note: Turn the operation mode switch gradually and lightly with the attached
screwdriver. Turning with excessive strength will cause damage to the
adjuster.
Multi-voltage type (L-ON / D-ON mode only)
DC-voltage type
Operation mode switch
Description
Detection-ON mode is obtained when the switch
is turned fully clockwise (L side).
Detection-OFF mode is obtained when the switch
is turned fully counterclockwise (D side).
Distance adjuster (2-turn)
Adjuster indicator
Stability indicator (Green)
Operation indicator (Orange)
OFF-delay timer adjuster (Note 2)
ON-delay timer adjuster (Note 2)
Operation mode switch (Note 1)
L D
BGS FGS
Timer ONOFF
N.C.N.C.
L-ON / D-ON mode
BGS / FGS mode
Timer mode
Not used
To maintain water-resistance, the cable should have
an outer diameter between ø9 to ø11 mm ø0.354 to
ø0.433 in with a smooth covering material that allows the
attached conduit connector to be securely tightened; the
tightening torque of the screw should be of 1.5 to 2.0 N·m.
If an external surge voltage exceeding 4 kV is impressed
(DC-voltage type: 1 kV), the internal circuit will be
damaged, and a surge suppressing element should be
used.
Prepare the cable end as shown below.
Dimensions of the suitable crimp terminals
Round type Y-shaped type
(After crimping)
7.5 0.295
or less
22 0.866
or less
17 0.669
or less
7 0.276
or less
10 0.394
or less
ø
3.6
ø0.142
or more
(After crimping)
7.5 0.295
or less
22 0.866
or less
17 0.669
or less
7 0.276
or less
10 0.394
or less
3.6 0.142
or more
(Unit: mm in)
Screw for terminal cover fixing
Screwdriver
The size of conduit is M20 × 1.5 mm 0.787 in.
If pressure terminals are to be used, afx the connected
pressure terminals to a terminal (M3.5 screw).
Conduit connector construction and cabling
Note: When assembling the conduit connector, pay attention to the direction
of the gland packing.
Furthermore, in order to maintain water-resistance, t the gland
packing such that the seating surface of the gland packing contacts
the packing holder part of the terminal cover evenly.
Gland packing (Note) Gland
Power supply
Conduit connector
Output
37 mm
1.457 in
25 mm
0.984 in
The tightening torque for the terminal screws should be
0.3 to 0.5 N·m.
Note: Use crimp terminals with insulating sleeves.
Recommended crimp terminal: Nominal size 1.25 × 3.5 0.049 × 0.138.
Adjustable Range Reective Photoelectric Sensor EQ-500 SERIES
370
Selection
Guide
Amplier
Built-in
Power Supply
Built-in
Amplier-
separated
CX-400
CY-100
EX-10
EX-20
EX-30
EX-40
CX-440
EQ-30
EQ-500
MQ-W
RX-LS200
RX
RT-610
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
PRECAUTIONS FOR PROPER USE
Stability indicatorTimer function (EQ-5□T only)
Since the EQ-500 series uses a 2-segment photodiode
as its receiving element, and sensing is done based
on the difference in the incident beam angle of the
reected beam from the sensing object, the output and
the operation indicator (orange) operate according to
the object distance.
Furthermore, the stability indicator (green) shows the
margin of the setting distance.
EQ-5□T incorporates an OFF-delay timer, which is
useful when the response of the connected device is
slow, etc., and an ON-delay timer, which is useful for
detecting objects that move slowly, for example.
The OFF-delay and ON-delay timers can be used
simultaneously.
For DC-voltage type, set the DIP switch for the timer
mode to ‘Timer ON’ side.
Unstable
operating condition
Setting distance
Output (Operation indicator)
(In case of Detection-ON)
Stability indicator
Stable operating
condition
Stable operating
condition
Sensing object
ON (Lights up)
OFF (Lights off)
Lights up
Lights off
Others
Do not use during the initial transient time (50 ms) after
the power supply is switched on.
Its distance adjuster is mechanically operated. Do not
drop; avoid other shocks.
DIMENSIONS (Unit: mm in)The CAD data in the dimensions can be downloaded from our website.
EQ-501(T) EQ-502(T) EQ-511(T) EQ-512(T)Sensor
26
1.024
68
2.677
68
2.677
2
0.079
58
2.283
22
0.866
30
1.181
58
2.283
5
0.197
5
0.197
OFF-delay timer adjuster (Note 2)
ON-delay timer adjuster (Note 2)
Stability indicator (Green) Operation mode switch (Note 1)
Distance adjuster (2-turn)
Adjuster indicator
Operation indicator (Orange)
Beam-
receiving part
Center of beam-
emitting
(Center of sensing)
3-M5 nut seats
(on both sides) 3-ø5.1 ø0.201
mounting holes
Notes: 1) The operation mode switch of the DC-voltage type is the DIP
switch.
2) For EQ-5□T only.
Assembly dimensions with sensor mounting bracket
MS-EQ5-01 (Optional) (Foot angled mounting)
6.5
0.256
58
2.283
58
2.283
5
0.197
Center of beam-
emitting
(Center of sensing)
2-M5 (length 30 1.181) screws
t 2
t 0.079
4
0.157
(10)
(0.394)
(10)
(0.394)
37
1.457
26
1.024
78
3.071
18
0.709
88
3.465
58
2.283
29
1.142
29
1.142
6.5
0.256
ø6.5
ø0.256
17.5
0.689
(30.5)
(1.201)
Material: Cold rolled carbon steel (SPCC)
Two M5 (length 30 mm 1.181 in) screws with washers and two nuts are attached.
Refer to p.1458~ for general precautions.
Time chart
Timer period: T = 0.1 to 5 sec. (variable)
Sensing
condition
Operation
Detection
normal operation
Detection ON-delay
Detection OFF-delay
Detection ON / OFF-delay
Non-detection
normal operation
Non-detection ON-delay
Non-detection OFF-delay
Non-detection
ON / OFF-delay
ON
OFF
ON
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
OFF
ON
OFF
T
T
T T T
T
T T T
TT
T
Detection
Non-
detection