P O W E R T R A N S F O R M E R
P C M O U N T : SPLIT PACK
Web: www.TriadMagnetics.com
Phone 951-277-0757
Fax 951-277-2757
22520B Temescal Canyon Road
Corona, California
92883 Publish Date: April 11, 2008
F120-050
Description:
The F120-050 is a single p rimary and dual secondary, split bobbin design which
operates with an input of 115V. The output voltage will be either 120.0V with a
center-t ap under a 0.05A load with the secondaries wired in series, or 60.0V
under a 0.1A load with the secondaries wired in parallel. The split bobbin design
eliminates the need for costly electrostatic shielding.
Electrical Specifications (@25C)
1. Maximum Power: 6.0VA
2. Primary: 115V
3. Secondary: Series: 120.0V CT@ 0.05A
Parallel: 60.0V @ 0.1A
4. Voltage Re gulation: 25% TYP @ full load to no load
5. Temperature Rise: 25C TYP
6. Hipot tested 100% at 2500 VRMS
Construction:
Three flange bobbin construction with primaries and secondaries wound side by
side for low capacitive coupling.
Agency File:
UL: File E53148, UL 5085-2 (506), Class B General Purpose Transformer,
cUL: File E53148, UL 5085-2 (506), Class B General Purpose Transformer,
Canadian Use (CSA 22.2, No.66.2-06)
Dimensions: Units in inches.
H W L A B C D E F
1.312 1.312 1.625 0.250 0.350 1.280 0.041 0.020 0.234
Weight: 0.44 lbs
Schematic:
1
4
8
7
6
5
115V
50/60Hz
RoHS Compliance:
As of manufacturing date February 2005, all standard products meet the
requirements of 2002/95/EC, known as the RoHS initiative.
As of April 7, 2008, UL standards 506 a nd 1585 will be migrated to UL 5085-2
and 5085-3, respectably.
* Upon printing, this document is considered ”uncontro lled”. Please contact
Triad Magnetics’ website for the most current version.
14
L
H
W
E
A
B
A
C
0.06" DIAMETER
HOLE
DF
1
58
4
Board Layout