ULTRASONIC FLOWMETER < M-Flow> DATA SHEET FLR, FLS, FLY This meter is a clamp-on type ultrasonic flowmeter for permanent use based on transit time measuring method. This flowmeter is designed to be suitable for machine mounting, thoroughly aimed at small size, light weight and ease of use. This flowmeter can be applied to the pipe size from 25 to 225mm, providing the best cost per performance. FEATURES Flow Transmitter (FLR) 1. Ease of use: The parameters necessary for measurement can be configured on the surface of Flow Transmitter's housing case by menu-driven software. The detector is mountable quickly and easily. 2. Compact and light weight: The adoption of the latest LSI technology and plastic housing has reduced the size and weight of the flow transmitter to one-fifth of our general use flow transmitter. 3. Superior temperature effect: The adoption of Sound Velocity Measurement System permits almost no influence from fluid temperature and pressure. 4. Quick response: With the use of fast-speed transit time processor, the system cycle is 0.2 sec that is applicable to short batch process. 5. Multilingual: The following languages are supported for display: English, Japanese, French, German and Spanish 6. Synchronization (option): Cross-talk between flowmeters located closely or acoustic interference between flowmeters installed on the same pipe line can be removed by using this synchronization function of transmission timing of ultrasonic waves. SPECIFICATIONS Operational specifications System configuration: The system is composed of a detector (Model FLS ... 1) and a flow transmitter (Model FLR...1), realizing single-path system. Application: Liquid flow without aeration that ultrasonic wave can propagate (purified water, cooling water, corrosive liquids, cooling/heating medium, etc.) Turbidity: 10000deg (mg/L) or less Fluid temperature: -20 to +100deg.C With silicon rubber for acoustic couplant 0 to +60deg.C With silicon-free grease for acoustic couplant ( ( ) ) Detector (FLS) Type of flow: Well-developed turbulent or laminar flow in a full-filled pipe Applicable flow pipe: Pipe size: 25 to 100mm (FLSE1) or 50 to 225mm(FLSE2) for plastic pipes 50 to 100mm (FLSE1) or 50 to 225mm (FLSE2) for metal pipes Material: Plastics (PVC, PVDF(Note), PEEK, PP(Note), FRP, etc.) or Metals (Carbon steel, SS, copper, aluminum, etc.) (Note)Measurement may not be made depending on diameter and thickness of the pipe. Contact us for details. Liner: Tar epoxy, mortar, rubber, and others Fundamental straight pipe: 10D for upstream and 5D for downstream (D: pipe diameter) Refer to "Conditions on straight pipe" for details. Velocity: 0 to 0.3 ... 10m/s Power supply: 100 to 120V AC 10%, 50/60Hz or 200 to 240V AC 10%, 50/60Hz or 20 to 30V DC Signal cable: RF co-axial cable up to 30m with water-proof BNC at one end and thermal stability of 100 deg.C Environment: Non-explosive environment without direct sunlight, corrosive gas and heat radiation EDS6-123e Date Dec. 1, 2003 FLR, FLS, FLY Ambient temperature: -20 to +50deg.C for flow transmitter -20 to +60deg.C for detector Ambient humidity: 90%RH or less Grounding: Class D (less than 100 ohm) Synchronization (option): Cross-talk when located closely or acoustic interference when installed on the same pipe line removable by simultaneous transmission of ultrasonic waves Number of connectable units: up to 31 Cable length: up to 15m Master/Slave selectable Arrester (option): Arrester unit for outputs available (while arrester for power supply incorporated as standard) Performance specifications Accuracy: Pipe size (inside dia.) 2m/s or more Less than 2m/s 25 to less than 50mm 3% of rate 0.06m/s 2% of rate 0.04m/s 50 to 225mm Communication interface (option): RS-232C equivalent / RS-485 Number of connectable units: one (RS-232C)/ up to 31 (RS-485) Baud rate: 2400/4800/9600/19200 bps selectable Parity: None/Odd/Even selectable Stop bit: 1 or 2 bits selectable Cable length: up to 15m (RS-232C)/up to 1km (RS-485) Data: Velocity, flow rate, +total, -total, status, etc. Display device: 2-color LED (Normal: green, Extraordinary: red) LCD with 2 lines of 16 characters and back light Display language: English, Japanese, French, German or Spanish selectable Velocity/Flow rate display: Display of velocity and/or flow rate with flow direction Number: 9 digits (decimal point be counted as 1 digit) Unit: Metric/Inch system selectable Velocity Response time: System cycle: 0.2s Dead time: less than 0.2s, Time constant: 0.1s Power consumption: 15VA or less for AC power supply 5W or less for DC power supply Permissible air volume rate: Up to 0.2% at 1 m/s (inversely proportional to velocity) Short-term thermal stability: 140deg.C, 30min 2 Inch system m/s ft/s Flow rate L/s, L/min, L/h, kL/h, ML/d, m 3/s, m 3/min, m3/h, Mm 3/d, BBL/s, BBL/min, BBL/h, MBBL/d gal/s, gal/min, gal/h, kgal/h, Mgal/d, ft3/s, ft 3 /min, ft 3 /h, Mft 3 /d, BBL/s, BBL/min,BBL/h, MBBL/d Note: The "gal" means USgal. Total display: Display of forward or reverse total Number: 7digits (decimal point be counted as 1digit) Unit: Metric/Inch system selectable Metric system Functional specifications Analog output:4 to 20 mA DC (1 point) Max. load resistance : 600 ohm Digital output:+ total, - total, alarm, acting range, flow switch or total switch arbitrarily available Transistor open collector: 1 point (DO1) Capacity: 30V DC, 0.1A Normal off/on selectable Total pulse: 1pulse/day to 100pps (Pulse width: 5, 10, 50, 100 or 200ms) Mechanical relay contact: 1point (DO2), with socket (exchangeable) Normal close/open selectable Capacity: 220V AC /30V DC, 1A (resistive load) Mechanical expected life: More than 2 x 107 operations Total pulse: 1pulse/day to 1pps (Pulse width: 50, 100 or 200ms) Metric system Total 3 3 Inch system 3 mL, L, m , km , Mm , mBBL, BBL, kBBL gal, kgal, ft3, kft3, Mft3, mBBL, BBL, kBBL, ACRE-in, ACRE-ft Configuration:Fully configurable from the 4-key pad (ESC, , , ENT) on the surface of flow transmitter's housing case by menu-driven software Zero adjustment: Set zero/Clear available Damping: 0 to 100s (every 1s) configurable for analog output and display Low flow cut off : 0 to 5m/s configurable Alarm: Hardware fault/Process fault applicable to digital output Burnout: Analog output : Hold/Over-scale/Under-scale/ Zero selectable Total: Hold/Count selectable Working timer : 0 to 100s (every 1s) configurable Bi-directional range: Forward and reverse ranges configurable independently Hysteresis: 0 to 10% of acting range configurable Acting range applicable to digital output Auto-2 ranges:Forward 2 ranges configurable independently Hysteresis:0 to 10% of acting range configurable Acting range applicable to digital output Flow switch: Lower and upper switching points configurable independently Acting point applicable to digital output Total switch: +total switching point configurable Acting point applicable to digital output Physical specifications Enclosure protection: IP65 for both flow transmitter and detector (When water-proof BNC is applied) Mounting: Flow transmitter: Wall/2B pipe mount Detector: Clamped on pipe surface Acoustic coupler: Silicon rubber or silicon-free grease Material: Flow transmitter: Plastic ABS Detector: Plastic PBT for sensor housing, 304SS for guide frame Sensor cable: 3D2V with outside diameter 5mm Dimensions: Flow transmitter: H140 x W139 x D68mm Detector: H28 x W240 x D50mm for FLSS1 H28 x W360 x D50mm for FLSS2 Mass: Flow transmitter: 0.8kg Detector: 0.3kg (FLSS1) / 0.4kg (FLSS2) 3 FLR, FLS, FLY Conditions on straight pipe ( D : Inside diameter of pipe) Classification Upstream side Downstream side 90 bend 10D or more L5D L10D 10D or more Detector Tee L10D L50D 0.5D or more 10D or more L30D D Diffuser L5D 1.5D L10D L5D Reducer L30D L10D Various Valve In case that flow control valve exists on upstream side. In case that flow control valve exists on downstream side. Stop valve Check valve L50D Pump P (Note) The source : JEMIS-032 4 MEASURING PRINCIPLE CODE SYMBOLS Sensor Upstream-side sensor 1 2 3 4 5 6 7 8 Flow transmitter Analog output D t1 Velocity V t2 1 F L RE 9 10 11 1 Y E Contact output Power Supply (5th digit) 100 to 120Vac, 50/60Hz 200 to 240Vac, 50/60Hz 20 to 30Vdc 2 3 4 Downstream-side sensor The transit-time technique uses a pair of sensors with each sensor sending and receiving ultrasonic signals obliquely through the fluid. When the fluid is flowing, transit-time in the forward direction is shorter than one in the reverse direction. As the difference between these transit-time is proportional to the velocity, the flow rate and direction can be measured properly by detecting such time difference. Communication & Synchronization (6th digit) None RS-232C RS-485 & Synchronization Synchronization Y A B C Arrester (7th digit) None With arresters for outputs Y A Modification No. (8th digit) Mark 1 1 Case structure (9th digit) IP65 1 CONFIGURATION Mounting bracket (10th digit) For 2B pipe mount For wall mount A B (1) Single-path system (V method) Y Cable Detector Flow transmitter 4 to 20mA DC Contact signals up to 2 points Cable Detector 2 F L SE 1 9 10 Y Y 4 to 20mA DC Kind of detector (5th to 6th digit) Small size detector (for 25 to 100mm) Middle size detector (for 50 to 225mm) 1 2 2 2 Contact signals Acoustic coupler (7th digit) None Silicon rubber (Fluid temperature: -20 to +100 deg.C) Silicon-free grease (Fluid temperature: 0 to +60 deg.C) Y A Synchronization B Cable Detector Flow transmitter (Slave) Description Type (4th digit) Standard E Flow transmitter (Master) Option (11th digit) None (Note) This type has not so tough endurance against aeration as Fuji's general use ultrasonic flowmeters TIME DELTA-S/F (Model: FLV/FLH) and PORTAFLOW-X (Model: FLC). For applications containing air bubbles, those general use flowmeters are recommendable to be used. 1 2 3 4 5 6 7 8 (2) When using synchronization Description Type (4th digit) Standard for exports 4 to 20mA DC Modification No. (8th digit) Mark 1 1 Contact signals Mounting method (9th digit) Standard (V-mount) Y Y Option (10th digit) None 1 2 3 4 5 6 7 8 F L Y 3 1 Description Kind of cable (4th digit) Heat resisting cable with water-proof BNC 3 0 0 0 0 0 0 1 1 2 3 Cable length (5th to 7th digit) 5m (one pair) 10m (one pair) 15m (one pair) 20m (one pair) 30m (one pair) 5 0 5 0 0 1 Modification No. (8th digit) Mark 1 5 FLR, FLS, FLY OUTLINE DIAGRAM (Unit:mm) 130 PIPE MOUNT (OPTION) Mtg. plate 2.5 67.5 Mtg. 2holes 9dia. 70 U bolt (M8) (197) 170 140 Mtg.pipe JIS 2B M-Flow 134.5 Cable gland For sensor cable (PG9) For power supply & output cable (PG13.5) External grounding terminal CONNECTION DIAGRAM RS-485 & Synchronization SYNC SHILD TXDR2 TXDR1 AC power supply 1 L 2 DC power supply RS-485 RS-232C GND HF1 GND HF2 I out DO1 DO2 Down- Downstream stream 2 20 to 30V DC 6 Synchronization N 100 to 120V AC or 200 to 240V AC 50/60Hz 1 UpUpI out DO1 DO2 stream stream (Note) DO1 : Transister open collector DO2 : Mechanical relay contact NC GND RXD TXD Saddle BNC connector L Spacing (Adustable every 3mm) Sensor Lock clip Frame H 34 (50) 28 SCOPE OF DELIVERY Flow transmitter FLR: * Flow transmitter Detector FLS: * * * * Instruction manual Sensor unit Mounting belt Silicon rubber/ Silicon-free grease (option) Signal cable FLY : Orignal cable (2 wires) Type Pipe size (mm) L H Spacing Mass. approx. (kg) FLSE1 25 to 100 240 31 21 to 120 0.3 FLSE2 50 to 225 360 30 21 to 240 0.4 The product conforms to the requirements of the Electromagnetic compatibility Directive 89/336/EEC as detailed within the technical construction file number TN513321. The applicable standards used to demonstrate compliance are : EN 61326 : 1998 Electrical equipment for measurement, control and laboratory use _____ EMC requirements 7 FLR, FLS, FLY Caution on Safety *Before using this product, be sure to read its instruction manual in advance. Head office 6-17, Sanbancho, Chiyoda-ku, Tokyo 102-0075, Japan http://www.fesys.co.jp Sales Div. International Sales Dept. No.1, Fuji-machi, Hino-city, Tokyo, 191-8502 Japan Phone: 81-42-585-6201, 6202 Fax: 81-42-585-6187 http: //www.fic-net.co.jp Information in this catalog is subject to change without notice. Printed in Japan