Cool CoolX600 NFF Series 600 TM NFF Series Patented Resonant Technology NFF Series; No Fan Featured * * * 100% natural convection cooled No internal or external fans needed No base-plate needed No Acoustic Noise or Vibrations & Breakthrough Level Reliability * * * * * * - No fans required - 600W with natural convection - MTBF >400000 hours - 25% better, than todays leading solutions High Input Surge Protection - 4KV Line to PE for harsh environments Reverse Energy Protection - No blocking diodes required 24W Standby Power Safety Approved to 5000m Altitude >93% Efficiency 5 Year Warranty Flexibility * * * * Analog and Digital Management - PMBus monitoring and control capability Field Configurable - Plug and Play Power Series and Parallel Outputs - Higher voltages/currents Mounting Options - Base/Side and DIN-Rail mounting Certifications * * Medical - IEC60601-1 3rd Edition compliant - IEC60601-1-2 4th edition EMC compliant - 2 MOPP - Dual Fused - BF rated - ISO13485 Industrial - IEC60950, IEC62368-1 - ISO9000 - SEMI F47 Defence/Aero - MIL810G certified - MIL461G, CE101, CE102 TYPICAL APPLICATIONS * Medical; Clinical diagnostic equipment, Medical lasers, Dialysis equipment, Radiological Imaging, Clinical Chemistry * Industrial; Test and Measurement, * Hi Rel; Harsh Industrial Electronics, Radar (Naval, Ground Based), Communications Test & Measurement Industrial Machines, Automation equipment, Printing, Telecommunications, Audio equipment www.excelsys.com The World's Only Fanless modular power supply, the CoolX600 NFF Series is the revolutionary new Convection-Cooled modular power supply from Excelsys. It provides an incredible 600W in a compact 4.5 x 8.5 x 1U package with no fan. The silent CoolX600 generates no acoustic noise and offers system designers best in class performance in efficiency (>93%) and unrivalled reliability in addition to the most comprehensive feature set and specifications. The series comprises two base models. The CX06S is certified to IEC60950 2nd edition for industrial applications whereas the CX06M carries IEC60601-1 3rd edition & IEC60601-1-2 4th edition (EMC) for medical applications. The CoolX600 can be populated with up to 4 CoolMods, providing up to 4 isolated DC outputs ranging from 2.5V to 58.0V. Continuing the Excelsys tradition of flexibility, the CoolX600 is completely user and field configurable. Outputs can be adjusted to the required set point voltages and can be configured in parallel or series for higher current and/or higher voltages. CoolPacs can be paralleled for higher power and N+1 Redundancy applications. Stand-out features for medical applications include BF rating (Body Floating), input dual fusing, 2 x MOPP isolation and <300uA leakage current. Other features include 4KV input surge immunity, SEMI F47 compliance, MIL810G compliance and the ability to withstand input voltages of up to 300VAC making it ideal for use in remote locations and those subject to input voltage disturbances. No fans make it ideal for acoustic and vibration sensitive applications. With Digital Communications available, the CoolX600 provides the most flexible, highest specification modular power supply in the market, all backed up by the Excelsys 5 Year Warranty ensuring quality and the lowest total cost of ownership CoolX CoolPac CoolPac Slots Power CX06S CX06M 4 4 600W 600W Medical Approval IEC60601-1 3rd edition & IEC60601-1-2 4th edition (EMC) Industrial Approval IEC60950 2nd edition Yes Yes - CoolX CoolMod Model Vnom (V) CmA CmB CmC CmD 5 12 24 48 Set Point Adjust Range (V) 2.5-6.0 6.0-15.0 15.0-28.0 28.0-58.0 Imax (A) Power (W) 21 15 8.33 4.17 105 180 200 200 1 CoolX600 NFF Series INPUT Parameter AC Operating Input Range Nominal Input Voltage Range Extended AC Operating Range DC Input voltage range Input Current Inrush Current Power Factor Undervoltage Lockout Input Fuses Rating Efficiency Conditions/Description Universal Input 47-440Hz Maximum for 5 seconds Min Nom 85 100 120 90VAC @ 420W 230VAC @ 600W 120VAC@ 500W Shutdown Dual Fused (Line and Neutral) 250VAC 230VAC, 600W with 3 x CmC CoolMods 0.98 65 Parameter Conditions/Description Min Power Rating Minimum Load Line Regulation Load & Cross Regulation Transient Response CX06: See derating curves Ripple and Noise Overvoltage Protection 100mV or 1.0% pk-pk. 20MHz BW Tracking OVP Level Latching OVP Level Max. line drop compensation Max Units 264 240 300 300 VAC VAC VAC VDC A A 6.0 25 74 VAC A % Max Unit 600 W A % % % S % % % VDC % ms ms ms ms ms 8 93 COOLMOD OUTPUT Remote Sense Overshoot Rise Time Turn-on Delay Hold-up Time CoolMod Power Output Adjustment Range Overcurrent Protection Short Circuit Protection OverTemperature Protection Capacitive Load AUXILIARY OUTPUT Parameter Nominal Output Voltage Load Regulation Line Regulation Maximum Output Current Maximum Output Capacitive Load Output Overcurrent Protection Short Circuit Protection Nom 0 For 10% change from nominal line For 25% to 75% load change For 25% to 75% load change 0.5A/uS: Voltage Deviation Settling Time Monotonic From AC in From Global Enable From CoolMod Enable For nominal output voltages at full load As per CoolMod table Manual: Multi-turn potentiometer. As per CoolMod table Vtrim: As per CoolMod table Straight line with hiccup activation @ 35% Vo nom Yes, Autorecovery Yes, Autorecovery 0.1 0.2 4 500 1 125 160 0.5 1 10 800 10 10 105 125 20 110 130 150 % 10 mF Conditions/Description Min Nom Max Units Aux Voltage Option A Aux Voltage Option B 11.76 4.75 12 5 12.24 5.25 2 0.5 1.96 4.7 1000 V V % % A A uF 140 % Max Units For 10% change from nominal line Aux Voltage Option A Aux Voltage Option B Hiccup Yes, Autorecovery 110 Parameter Conditions/Description Min Input to Output Input to Case Output to Case Output to Output Reinforced (2 x MOPP) Basic (1 x MOPP) Basic (1 x MOPP) Basic (1 x MOPP) 4000 1850 1850 1850 GALVANIC ISOLATION 2 Nom VAC VAC VAC VAC www.excelsys.com CoolX600 NFF Series RELIABILITY Parameter Conditions/Description Reliability and MTBF MTBF of >400 kHours, Telecordia SR-332, Issue 1 Warranty 5 Years Min CoolMod CoolPac Nom Max 0.52 1.08 Units Fpmh Fpmh ENVIRONMENTAL Parameter Conditions/Description Min Max Units Operating Temperature Storage Temperature Derating Relative Humidity Shock & Vibration Altitude Operates to specification below -20C after 10 min warm-up -40 -40 +70 +85 C C 5 95 %RH 5000 m See Derating Curves including note 2 Non-condensing MIL-STD810G Method 514.6 Nom LEAKAGE CURRENTS Parameter Conditions/Description AC Leakage Current Normal condition (high line) Single fault condition (high line) Touch Current Normal Condition Single Fault Condition Input to earth ground Mains Voltage 264VAC/60Hz Mains Voltage 264VAC/60Hz 44 231 Units A A Mains Voltage 264VAC/60Hz Mains Voltage 264VAC/60Hz 83 87 A A EMC Parameter Conditions/Description Criteria Radiated Emissions Conducted emissions Power line harmonics Voltage flicker ESD Radiated immunity Electrical fast transient Surge immunity Conducted RF immunity Power frequency magnetic field EN 55011, EN 55022 and FCC, Class B EN 55011, EN 55022 and FCC, Class B EN 61000-3-2, Class A EN 61000-3-3 EN 61000-4-2, level 4, 8 kV contact, 15 kV air EN 61000-4-3, level 2, 3 V/m EN 61000-4-4, level 4, 4 kV EN 61000-4-5, level 4, 2 kV DM, 4 kV CM EN 61000-4-6, level 2, 3 Vrms EN 61000-4-8, level 2, 3 A/m A A B B A A STANDARDS & DIRECTIVES 1) Parameter Conditions/Description Safety Agency Approvals EN60601-1 3rd Edition, UL60601-1, CSA601, EN60950 2nd Edition, CSA C22.2 No. 60950-1, IEC/EN 60950-1, Edition 2 and UL 60950-1/CSA 22.2 No 60950-1, Edition 2; all national deviations 5000 m (16,400 ft) altitude, 100 V to 240 10% Vac IEC/EN 60601-1, Edition 3 and IEC 60601-1(2005), EN60601-1(2006) all national deviations ANSI/AAMI ES 60601-1(2005) CAN/CSA C22.2 No. 60601-1 (2008); 5,000 m (16,400 ft) altitude, 100 V to 240 Vac 10% IEC 62368 Edition 2 IEC 62368-1 (2014) Edition 2 5000 m (16,400 ft) altitude,100 V to 240 10% Vac IEC 60601-1-2 Edition 4 IEC 60601-1-2 (2014) Protection class Class I WEEE Waste Electrical and Electronic Equipment Directive (WEEE) 2002/96/EC ROHS EU DIRECTIVE 2011/65/EC RoHS compliancy REACH Compliant 1) Designed to support Type B and Type BF Applied Part End Product Requirements www.excelsys.com 3 CoolX600 NFF Series MECHANICAL DATA Parameter Description Dimensions (L x W x H) Weight Connectors AC/DC input terminal block AC/DC IEC input (Option) Main DC output terminal block System Signal Connector J1005 LxWxH Nominal Weight: CoolPac + 4 x CoolMods Description TE 2-1437667-S, DINKLE DT-35-B07W-03 IEC 320 Inlet M4 Screws Molex 87833-0831 8-way Output Signal Connectors J1001-1004 Molex 87833-0631 6-way Output Sense Connectors J3 JST-S2BPH-K(LF)(SN) Auxiliary Output Connector J1 Molex 1041880210 2pin 215.9mm x 114.3mm x 39.1mm 4.5" x 8.5" x 1U 1Kg Mating Connectors (if applicable) Locking Molex 51110-0860; Non Locking Molex 511100850; Crimp Terminal: Molex p/n 50394 or Molex 51110-0856 which includes Locking Tab & Polarization Keying Locking Molex 51110-0660; Non Locking Molex 51110-0650; Crimp Terminal: Molex p/n 50394 or Molex 51110-0656 which includes Locking Tab & Polarization Keying JST PHR2. Crimp Terminal JST BPH-002T-P.0.5S or SPH-002T-P.05S CoolX Mechanical Drawings 162.00 162.00 39.10 39.10 19.55 19.55 6.00 6.00 3.00 3.00 24.25 24.25 114.30 114.30 36.15 36.15 42.00 42.00 215.90 215.90 24.25 24.25 24.25 24.25 31.50 31.50 122.00 122 CoolX can be mounted on its base, vertically or on its side. CoolX can also be mounted on the Excelsys DIN Rail accessory (Z744). 4 www.excelsys.com CoolX600 NFF Series CoolX 600 Efficiency, Derating and Power Limit Curves 115V 230V CoolX Derating 2) Enhanced thermal performance with system fans & base plate cooling. Consult Excelsys for details. Configuring Your CoolX www.excelsys.com 5 CoolX600 NFF Series CoolX Connectors Input Connectors Standard (Screw Terminal) Option 1 (IEC Terminal) CoolPac Connectors CoolMod Connectors Specifications are subject to change REVJUNE16 6 www.excelsys.com