DATA SHEET S524C20D11/20D21/80D41/80D81 SERIAL EEPROM
3-15
Table 3-4. D.C. Electrical Characteristics (Continued)
(TA = – 25°C to + 70°C (C), – 40°C to + 85°C (I), VCC = 2.2 V to 5.5 V when reading, 2.5 V to 5.5 V when writing)
Parameter Symbol Conditions Min Typ Max Unit
Input capacitance CIN 25°C, 1MHz,
VCC = 5 V, VIN = 0 V,
A0, A1, A2, SCL and WP pin
– – 10 pF
Input/output capacitance CI/O 25°C, 1MHz,
VCC = 5 V, VI/O = 0 V,
SDA pin
– – 10
Table 3-5. A.C. Electrical Characteristics
(TA = – 25°C to + 70°C (C), – 40°C to + 85°C (I), VCC = 2.2 V to 5.5 V when reading, 2.5 V to 5.5 V when writing)
Parameter Symbol
Conditions
VCC = 2.2 to 5.5 V
(Standard Mode) VCC = 4.5 to 5.5 V
(Fast Mode) Unit
Min Max Min Max
External clock frequency FCLK – 0 100 0 400 kHz
Clock high time tHIGH – 4 – 0.6 – µs
Clock low time tLOW – 4.7 – 1.3 –
Rising time tR SDA, SCL – 1 – 0.3
Falling time tF SDA, SCL – 0.3 – 0.3
Start condition hold time tHD:STA
– 4 – 0.6 –
Start condition setup time tSU:STA
– 4.7 – 0.6 –
Data input hold time tHD:DAT
– 0 – 0 –
Data input setup time tSU:DAT
– 0.25 – 0.1 –
Stop condition setup time tSU:STO
– 4 – 0.6 –
Bus free time tBUF Before new
transmission
4.7 – 1.3 –
Data output valid from
clock low (note) tAA – 0.3 3.5 – 0.9
Noise spike width tSP – – 100 – 50 ns
Write cycle time tWR – – 10 – 10 ms
NOTE: When acting as a transmitter, the S524C20D11/20D21/80D41/80D81 must provide an internal minimum delay time
to bridge the undefined period (minimum 300 ns) of the falling edge of SCL. This is required to avoid unintended
generation of a start or stop condition.