2
D2TD2T
Specifications
■Ratings
Note: The ratings values apply under the following trest conditions:
Ambient temperature: 20±2°C
Ambient humidity: 65±5%
Operating frequency: 30 operations/min
■Characteristics
Note: 1. The data given above are initial values.
2. The dielectric strength shown in the table indicates a value for models with a Separator.
3. For the pin plunger models, the above values apply for use at both the free position and total travel position. For the lever models,
they apply at the total travel position. Contact opening or closing time is within 1 ms.
4. For testing conditions, consult your OMRON sales representative.
Rated voltage Resistive load
Between terminals 1 and 2 250 VAC 5 A
Between terminals 3 and 4 125 VAC 0.1 A
Operating speed 10 mm to 500 mm/s (pin plunger models)
Operating frequency Mechanical: 120 operations/min max.
Electrical: 30 operations/min max.
Insulation resistance 100 MΩ min. (at 500 VDC)
Contact resistance (initial value) Between terminals 1 and 2: 50 mΩ max.
Between terminals 3 and 4: 100 mΩ max.
Dielectric strength (see note 2) 1,000 VAC for 1 min 50/60 Hz between terminals of same polarity
1,500 VAC for 1 min 50/60 Hz between current-carrying metal part and ground (see note 1), be-
tween each terminal and non-current-carrying metal part, and between terminals of different po-
larity
Vibration resistance (see note 3) Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Shock resistance (see note 3) Destruction: 1,000 m/s2 {approx. 100G} max.
Malfunction: 300 m/s2 {approx. 30G} max.
Durability (see note 4) Mechanical: 100,000 operations min. (60 operations/min)
Electrical: 100,000 operations min. (30 operations/min)
Degree of protection IEC IP40
Degree of protection against electric
shock
Class I
Proof tracking index (PTI) 175
Ambient operating temperature –25°C to 85°C (at ambient humidity of 60% max.) (with no icing or condensation)
Ambient operating humidity 85% max. (for 5°C to 35°C)
Weight Approx. 10 g (pin plunger models)