COOLX(R)600 FANLESS, NATURAL CONVECTION-COOLED MODULAR POWER SUPPLY = Advanced Energy's CoolX(R)600 series, part of our low voltage solutions, is the world's first fanless, natural convection-cooled modular power supply. The CoolX600 delivers an incredible 600 W without fan-assisted cooling from a very compact package. The CoolX600 offers system designers best-in-class efficiency and reliability in addition to the most comprehensive feature set and specifications available. PRODUCT HIGHLIGHTS No Fan Featured 600 W with 100% natural convection cooling No base plate needed N o acoustic noise or vibrations Reliability MTBF > 400,000 hours, 25% better than today's leading solutions High input surge protection -- 4 KV line to PE for harsh environments Reverse energy protection -- no blocking diodes required 24 W always ON auxiliary power output Safety approved to 5000 m altitude > 94% efficiency F ive-year warranty Flexibility Analog and digital management -- PMBusTM monitoring and control capability Field-configurable -- plug and play power Series and parallel outputs -- higher voltages/currents Mounting options -- base/side and DIN-Rail mounting TYPICAL APPLICATIONS Medical Clinical diagnostic equipment, medical lasers, dialysis equipment, radiological imaging, clinical chemistry Industrial Test and measurement, industrial machines, automation equipment, printing, telecommunications, audio equipment Hi Rel Harsh industrial electronics, radar (navaland ground-based), communications, test and measurement AT A GLANCE CX06S CX06M Power 600 W 600 W Slots 4 4 Cooling No fan featured, convection-cooled Parameters 215.9 mm x 114.3 mm x 39.1 mm (8.5 in x 4.5 in x 1 U) Certifications Medical IEC60601-1 3rd edition, IEC60601-1-2 4th edition (EMC) 2 MOPP Dual fused Suitable for type B- and BF-rated applications ISO13485 Industrial IEC60950, IEC62368-1 ISO9000 SEMI F47 Defense/Aero MIL-STD-810G COOLX600 SERIES MODULES CoolX CoolMods Table CoolMod Vnom(V) Set Point Adjust Range (V) Imax(A) Power (W) CmA1 5 2.5-6.0 21.0 105 CmB1 12 6.0-15.0 15.0 180 CmC1 24 15.0-28.0 8.3 200 CmD 48 28.0-58.0 4.2 200 CmE 24 22.8-25.2 25.0 600 CmF 48 45.6-50.4 12.5 600 3.0-30.0 3.0 90 1 High Power Modules (3 Slot) Dual Output Modules (1 Slot) CmG2 V1 V2 24 24 3.0-30.0 3.0 90 5 3.0-6.0 6.0 36 24 3.0-30.0 3.0 90 CmM 5 1.0-6.0 21 105 CmN 12 1.0-15.0 15 180 CmP 24 1.0-28.0 8.33 200 CmQ 48 3.0-58.0 4.17 200 CmH3 V1 V2 Wide Trim Modules (1 Slot) 1 Full dynamic specifications may not be met at full load when output voltage is trimmed above 13 V. 2 For the CmG module the max combined power of both outputs is 120 W. 3 For the CmH module the max combined power of both outputs is 100 W. ELECTRICAL SPECFICATIONS Input Parameter Conditions/Description AC Operating Input Range Min Nom 264 Units 85 -- 264 VAC Nominal Input Voltage Range Universal Input 47-440 Hz 100 -- 240 VAC Extended AC Operating Range Maximum for 5 seconds -- -- 300 VAC DC Input Voltage Range 120 -- 300 VDC Input Current 90 VAC @ 420 W -- 6 -- A Inrush Current 230 VAC @ 600 W -- -- 25 A Power Factor 120 VAC @ 500 W 0.98 -- -- -- Undervoltage Lockout Shutdown 65 74 VAC Input Fuses Rating Dual Fused (Line and Neutral) 250 VAC -- 8 -- A Efficiency 230 VAC, 600 W with 3 x CmC CoolMods -- 93 -- % 230 VAC, 600 W with 1 x CmE CoolMod -- 94 -- % CX06: See derating curves -- -- 600 W 0 -- -- A For 10% change from nominal line -- -- 0.1 -- CmF, CmG, CmH -- -- 0.5 % For 25% to 75% load change -- -- 0.2 % Output Power Rating Minimum Load Line Regulation Load and Cross Regulation 2 advancedenergy.com COOLX600 SERIES ELECTRICAL SPECIFICATIONS (CONTINUED) Output (Continued) Parameter Conditions/Description Min Nom 264 Units Transient Response For 25% to 75% load change 0.5 A/uS: voltage deviation -- -- 4 (4) % *CmE and CmF, CmG, CmH Figures in () Settling Time -- -- 500 (1000) S 100 mV or 1.0% pk-pk. 20 MHz BW -- -- 1 % CmF -- -- 1.5 % Tracking OVP Level (N/A in CmE and CmF, CmG, CmH) 105 -- 125 % Ripple and Noise Overvoltage Protection Latching OVP Level 110 -- 160 % Remote Sense Max line drop compensation (N/A in CmG and CmH) -- -- 0.5 VDC Rise Time Monotonic CmG, CmH Figures in () -- -- 10 (20) ms Turn-On Delay From AC in *CmE and CmF, CmG, CmH Figures in () -- -- 800 ms From Global Enable -- -- 10 (20) ms From CoolMod Enable -- -- 10 (20) ms Hold-Up Time For nominal output voltages at full load 20 -- -- ms CoolMod Power As per CoolMod table -- -- -- -- Output Adjustment Range Manual: Multi-turn potentiometer, as per CoolMod table Vtrim: As per CoolMod table -- -- -- -- Overcurrent Protection Straight line with hiccup activation @ 35% Vo nom CmE and CmF, CmG, CmH: Current limit hiccup autorecovery CmM, CmN, CmP and CmQ: Straight line with hiccup activation at 70% of Vo min 110 130 150 % Short Circuit Protection Yes, Autorecovery -- -- -- -- Over Temperature Protection Yes, Autorecovery (CmG, CmH latch off ) -- -- -- -- Capacitive Load Nominal output voltages at full load -- -- 10 mF CmG, CmH -- -- 270 uF Auxiliary Output Parameter Conditions/Description Min Nom Max Units Nominal Output Voltage Aux voltage option A 11.76 12 12.24 V Aux voltage option B Load Regulation 4.75 5 5.25 V -- -- 2 % Line Regulation For 10% change from nominal line -- -- 0.5 % Maximum Output Current Aux voltage option A -- -- 1.96 A Aux voltage option B Maximum Output Capacitive Load -- -- 4.7 A -- -- 1000 uF 140 % -- -- -- Output Overcurrent Protection Hiccup 110 Short Circuit Protection Yes, autorecovery -- Galvanic Isolation Parameter Conditions/Description Min Nom Max Units Input to Output Reinforced (2 x MOPP); contact Advanced Energy for Hi-Pot instructions 4000 -- -- VAC Input to Case Basic (1 x MOPP) 1850 -- -- VAC Output to Case Basic (1 x MOPP) 1850 -- -- VAC Output to Output Basic (1 x MOPP) 1850 -- -- VAC Output to Output (Dual) CmG, CmH V1-V2 500 -- -- VDC advancedenergy.com 3 COOLX600 SERIES ELECTRICAL SPECIFICATIONS (CONTINUED) Reliabilty Parameter Conditions/Description Reliability and MTBF MTBF of > 400 kHours, Telecordia SR-332, Issue 1 Warranty 5 years Min CoolMod -- CoolPac -- -- Nom Max Units 0.52 -- Fpmh 1.08 -- Fpmh -- -- -- Environmental Parameter Conditions/Description Min Nom Max Units Operating Temperature Operates to specification below -20C after 10 min warmup -40 -- 85 C -40 -- 85 C See Derating Curves including note 5 -- -- -- -- Storage Temperature Derating Relative Humidity Non-condensing 5 -- 95 %RH Shock and Vibration MIL-STD-810G Method 514.6 -- -- -- -- -- -- 5000 m Altitude Leakage Currents Parameter Conditions/Description Nom Units -- AC Leakage Current Input to Earth Ground -- Normal Condition (High Line) Mains Voltage 264 VAC / 60 Hz 248 A Single Fault Condition (High Line) Mains Voltage 264 VAC / 60 Hz 393 A Touch Current Normal Condition Mains Voltage 264 VAC / 60 Hz 4.7 A Single Fault Condition Mains Voltage 264 VAC / 60 Hz 247 A EMC Parameter Conditions/Description Units Radiated Emissions4 EN 55011, EN 55022 and FCC, Class B Compliant Conducted Emissions EN 55011, EN 55022 and FCC, Class B Compliant Power Line Harmonics EN 61000-3-2, Class A Compliant Voltage Flicker EN 61000-3-3 Compliant ESD EN 61000-4-2, level 4, 8 kV contact, 15 kV air A Radiated Immunity EN 61000-4-3, level 2, 3 V/m A Electrical Fast Transient EN 61000-4-4, level 4, 4 kV B Surge Immunity EN 61000-4-5, level 4, 2 kV DM, 4 kV CM B Conducted RF Immunity EN 61000-4-6, level 3, 10 Vemf 150 KHz-80 MHz A Power Frequency Magnetic Field EN 61000-4-8, level 4, 30 A/m A 4 4 Consult AE applications for system level compliance Standards and Directives4 Parameter Safety Agency Approvals IEC/EN 60950-1, Edition 2 and All National Deviations Conditions/Description EN60601-1 3rd Edition, UL60601-1, CSA601 EN60950 2nd Edition, CSA C22.2 No. 60950-1 UL 60950-1/CSA 22.2 No 60950-1, Edition 2 5000 m (16,400 ft) altitude, 100 V to 240 10% VAC IEC 60601-1(2005), EN60601-1 (2006) IEC/EN 60601-1, Edition 3 and All National Deviations ANSI/AAMI ES 60601-1 (2005) CAN/CSA C22.2 No. 60601-1 (2008) 5,000 m (16,400 ft) altitude, 100 V to 240 VAC 10% 4 advancedenergy.com COOLX600 SERIES ELECTRICAL SPECIFICATIONS (CONTINUED) Standards and Directives (Continued)4 Parameter Conditions/Description IEC 62368 Edition 2 IEC 62368-1 (2014) Edition 2 5000 m (16,400 ft) altitude, 100 V to 240 10% VAC IEC 60601-1-2 Edition 4 IEC 60601-1-2 (2014) Protection Class Class I WEEE Waste Electrical and Electronic Equipment Directive (WEEE) 2002/96/EC ROHS EU DIRECTIVE 2011/65/EC RoHS compliancy REACH Compliant 4 Designed to support Type B and Type BF Applied Part End Product Requirements. BF rating achieved with CoolX600 configured without a cover. MECHANICAL SPECIFICATIONS Mechanica Data Parameter Description Min Dimensions (L x W x H) 215.9 mm x 114.3 mm x 39.1 mm (8.5 in x 4.5 in x 1 U) Weight Nominal Weight: CoolPac + 4 x CoolMods 1 Kg Connectors Description Mating Connectors (if applicable) AC/DC input terminal block TE 2-1437667-S, DINKLE DT-35-B07W-03 -- AC/DC IEC input (Option) IEC 320 Inlet -- Main DC output terminal block (CmA-CmF, CmM-CmQ) M4 Screws -- Main DC output terminal block (CmG, CmH) Camden - CTB9350/4A -- Output Signal Connector (CmG, CmH) Molex - 87833-0831 -- System Signal Connector J1005 Molex 87833-0831 8-way Locking Molex 51110-0860; Non Locking Molex 51110-0850; Crimp Terminal: Molex p/n 50394 or Molex 51110-0856 which includes locking tab and polarization keying Output Signal Connectors J1001-1004 Molex 87833-0631 6-way Locking Molex 51110-0660; Non Locking Molex 51110-0650; Crimp Terminal: Molex p/n 50394 or Molex 51110-0656 which includes locking tab and polarization keying Output Sense Connectors J3 JST-S2BPH-K(LF)(SN) JST PHR2. Crimp Terminal JST BPH-002T-P.0.5S or SPH-002T-P.05S Auxiliary Output Connector J1 Molex 1041880210 2pin -- Mechanical Drawings 162.00 39.10 19.55 6.00 3.00 24.25 24.25 24.25 114.30 36.15 42.00 215.90 31.50 122.00 CoolX can be mounted on its base, vertically, or on its side. CoolX can also be mounted on the DIN Rail Accessory (Z744). advancedenergy.com 5 COOLX600 SERIES INTERFACE 5 Enhanced thermal performance with system fans and base plate cooling. Contact Advanced Energy for details. Input Connectors Standard (Screw Terminal) CoolPac Connectors 6 advancedenergy.com Option 1 (IEC Terminal) COOLX600 SERIES INTERFACE (CONTINUED) CoolMod Connectors CONFIGURATION CoolMods 0 = Unpopulated # = Unavailable CoolPac CX06-600W A = CmA B = CmB C = CmC D = CmD E = CmE F = CmF G = CmG H = CmH M = CmM N = CmN P = CmP Q = CmQ Connectors & Leakage Current - = Screw Terminal, Normal Leakage 1 = IEC Terminal, Normal Leakage 4 = Screw Terminal, Low Leakage (150 uA) 5 = IEC Terminal, Low Leakage (150 uA) Open Frame / Enclosed Not used or - = Standard Model L = Cover Logistic Use Only S/M S = Standard M = Medical Settings + CoolPac Options N = Unconfigured C = Conformal Coating S = Ruggedized + Conformal Coating P = Configured X = Internal Use Only Aux Voltage A = 12 V Aux (Standard) B = 5 V Aux advancedenergy.com 7 ABOUT ADVANCED ENERGY Advanced Energy (AE) has devoted more than three decades to perfecting power for its global customers. AE designs and manufactures highly engineered, precision power conversion, measurement and control solutions for mission-critical applications and processes. AE's power solutions enable customer innovation in complex semiconductor and industrial thin film plasma manufacturing processes, demanding high and low voltage applications, and temperature-critical thermal processes. With deep applications know-how and responsive service and support across the globe, AE builds collaborative partnerships to meet rapid technological developments, propel growth for its customers and power the future of technology. Specifications are subject to change without notice. Not responsible for errors or omissions. (c)2019 Advanced Energy Industries, Inc. All rights reserved. For international contact information, visit advancedenergy.com Advanced Energy(R) and AE(R) are U.S. trademarks, and CoolX(R) is a U.S. and European trademark of Advanced Energy Industries, Inc. ENG-LV-COOLX600-235-02 8.19