Catalogue
SICK
Sensors for Automation
Inductive Proximity Sensors Capacitive Proximity Sensors
Magnetic Proximity Sensors Magnetic Cylinder Sensors
6SICK 8 007 755.0300
Glossary General.................................................................................................... 8
Electrical ................................................................................................ 11
Standards .............................................................................................. 13
Inductive proximity sensors Operating principle ................................................................................. 14
Glossary ................................................................................................ 15
Installation notes..................................................................................... 16
Selection table........................................................................................ 18
Type code.............................................................................................. 19
Series .........................DC 3/4-wire......IM 0 4 ........................................20
IM 0 5 ........................................22
IM 0 8 ........................................24
IM 1 2 ........................................30
IM 1 8 ........................................40
IM 3 0 ........................................50
IH 0 3.........................................56
IH 0 4.........................................58
IH 0 6.........................................60
IQ 0 5 ........................................64
IQ 0 8 ........................................66
IQ 1 0 ........................................68
IQ 1 2 ........................................70
IQ 4 0 ........................................72
IQ 8 0 ........................................76
Series ...................... DC 2-wire ..........IM 1 2 ........................................78
IM 1 8 ........................................80
IM 3 0 ........................................82
Series ........................AC, AC/DC.......IM 1 2 ........................................8 4
IM 1 8 ........................................86
IM 3 0 ........................................88
IH 2 0.........................................90
IH 3 4.........................................92
IQ 4 0 ........................................94
IQ 8 0 ........................................96
Series ........................NA MUR............I M 0 8 ........................................98
IM 1 2 ......................................100
IM 1 8 ......................................102
IM 3 0 ......................................104
Capacitive proximity sensors Operating principle ............................................................................... 106
Selection table...................................................................................... 107
Type code............................................................................................ 107
Series .........................DC ...................CM 1 8 ....................................108
CM 3 0 ....................................110
CQ 3 5.....................................112
Contents
7
SICK8 007 755.0300
Magnetic Operating principle ............................................................................... 114
proximity sensors Glossary .............................................................................................. 115
Installation notes................................................................................... 118
Selection table...................................................................................... 119
Type code............................................................................................ 119
Series .........................D C ...................MM 0 8....................................120
MM 1 2....................................122
MM 1 8....................................124
MQ 1 0 ....................................126
Series ........................N A M U R............MM 1 2....................................128
MM 1 8....................................130
Magnetic cylinder sensors Operating principle ............................................................................... 132
Product overview.................................................................................. 133
Type code............................................................................................ 135
Series .........................D C ...................MZ R 1.....................................136
MZ R 2.....................................1 3 8
MZ Z 1.....................................140
MZ Z 2.....................................142
MZ P 3.....................................144
MZ P 4.....................................146
MZ K 1.....................................1 4 8
MZ K 3.....................................1 5 0
MZ F 1 .....................................152
MZ T 1.....................................15 4
RZ T 1 .....................................156
MZ U 2 ....................................158
Series .........................NAMUR............MZR2 .....................................160
MZ Z 1.....................................162
MZ P 3.....................................164
MZ P 4.....................................166
Accessories, control units Control unit EN 2.................................................................................. 168
Isolating Control unit EN 2 Ex ................................................................ 172
Round connectors................................................................................ 174
Magnets .............................................................................................. 176
Mounting brackets................................................................................ 177
Index Type designation .................................................................................. 178
Order number ...................................................................................... 182
Sensors from SICK .....................................................................................................................................187
Inductive proximity sensors
Magnetic proximity sensors Capactive proximity sensors
Accessories, control units Magnetic cylinder sensors
8SICK 8 007 755.0300
Active switching zone
Area above the sensing face in which
a proximity sensor responds by a
change in switching status when
attenuating material is brought nearer.
Cables
PUR cable
oil-resistant cable
not resistant to hydrolysis
PVC cable
not suitable for continuous use in
environments containing oil
not ozone- or UV-resistant
PUR-PVC cable
PVC cable coated with PUR
The cables must not be moved in
temperatures below -5 °C otherwise
they may rupture.
Complementary output
A DC 4-wire with one NO and NC
output that can be used at the same
time.
Continuous current Ia
Current at which the proximity sensor
can function reliably.
Enclosure rating
The conditions for the enclosure
rating IP 68 are the following at the
SICK AG:
-1 m water depth
-temperature of 20° C
-permanent immersion
EMC
Electromagnetic compatibility
Glossary
General
Flush installation
A proximity sensor can be embedded
in an attenuating
material so that it is flush with
the active surface.
NPN output
Proximity sensors with NPN output
switch the negative potential to the
load. They are also described as
negative-switching or current-sinking.
Load
+
-Output
Output function
Normally open: A proximity sensor
with make function is disabled in the
unattenuated state (high resistance)
and is switched in the attenuated
state (low resistance).
Operating voltage Ub
Voltage range in which the proximity
sensor can function reliably.
Overload resistance
See also short-circuit protection.
The response threshold for overload
protection is greater than the value for
continuous current-carrying capacity.
Normally closed: A proximity sensor
with brake function is switched in the
unattenuated state (low resistance)
and disabled in the attenuated state
(high resistance).
Housing material
Brass, nickel-plated
Stainless steel
Aluminium
Plastic ( PA12, PBT, PPE )
If the sensors are to be frequently or
continuously exposed to chemicals,
an application test must be
performed. Contact SICK AG for
further information.
Hysteresis H
The hysteresis is the positional
difference between the activation and
deactivation point for attenuating
material as it is brought closer or
moved away. It is required to ensure
a smooth, stable switching action. It
is given as a percentage of the real
sensing range or in mm.
Minimum load current
Smallest load current that must flow
with connected output in order to
ensure the reliable operation of
2-wire proximity sensors.
Non-flush installation
A proximity sensor must be installed
in such a way that a free-zone is
maintained.
9
SICK8 007 755.0300
Peak current Ik
Current that may flow for a specified
period at a defined switching
frequency without destroying the
proximity sensor.
PNP output
Proximity sensors with PNP output
switch the positive potential to the
load. They are also described as
positive-switching or current-
sourcing.
+
-
Load
Output
Power-up pulse suppression
The power-up pulse suppression
ensures that no incorrect switching
signal is sent to the output between
the time when the operating voltage
is applied and when the oscillator
begins to oscillate.
Repeatability R
Switching point difference for the
useful sensing range between two
consecutive measurements under
identical conditions.
Residual current Ir
The residual current is used to supply
power to the 2-wire sensors and also
flows across the load if the output is
disabled.
Reverse polarity protected
(with NAMUR sensor to EN 50227)
The connections of the proximity
sensor can be connected to the
wrong terminals without the sensor
being damaged.
Reverse polarity protection
An internal protection circuit prevents
the DC 3/4-wire proximity sensors
from being destroyed if the supply
voltage connections are incorrectly
connected, and also ensures that no
misoperation can occur which would
result in an undesired signal being
issued.
Ripple Upp
The DC operating voltage of the
ripple voltage content (maximum
permissible peak value, given in %
of Ub).
U
U
b
U
pp
t
Sensing face
Surface of a proximity sensor to
which the sensing range relates.
Sensing range
The sensing range of a proximity
sensor is the distance at which one of
the measuring plates being moved
axially towards the active surface
triggers a signal change.
su min.
sn
sr min.
sr max.
su max.
sr
1.1sn
0.9sn
su
0.81sn
1.21sn
sa
Measuring plate
Sensing face
Proximity
sensor
Rated sensing range sn:
Device characteristics
Real sensing range sr:
0.9 sn sr 1.1 sn
Useful sensing range su:
0.9 sr su 1.1 sr
Actuation distance sa:
The actuation distance is the distance
at which a proximity sensor reacts
under specified temperature and
voltage conditions.
It is between 0% and 81% of the
rated sensing range.
10 SICK 8 007 755.0300
Glossary
General
Shock stress
Pulse shape: semi-sinoidal
Acceleration: 30 gn
Pulse length: 11 ms
Short-circuit protection
Proximity sensors with short-circuit
protection cannot be destroyed by
either overloading or a direct short-
circuit. When the triggering threshold
is exceeded, the output is disabled
and then periodically (in cycles) polled
to establish whether the short-circuit
still exists. An automatic reset is
performed once the short-circuit has
been eliminated.
Short-circuit protection (with
NAMUR sensor to EN 50227)
The proximity sensor is not destroyed
if the load short-circuits or in the case
of a short-cirtcuit to ground at the
output.
Status indicator
The forced triggering of the output
(low-resistance) is indicated by an
LED. With some sensors, standby is
indicated by a second LED.
Switching frequency f
Maximum number of switching
actions per second.
Disk
2a
s
n
2
aMeasuring
plate
Proximity
sensor
Temperature drift
Shifting of the switching point caused
by a change in ambient temperature.
Time delay before availability tv
Time required by the proximity sensor
to become operational after the
operating voltage is applied.
Vibration stress
Frequency range: 10 to 55 Hz
Amplitude: 1 mm
Vibration length: 5 min
Endurance at
resonance frequency
or at 55 Hz: 30 min. in
each axis
Voltage drop Ud (at Ia max)
Reduction in voltage occurring at
maximum load current across the
switching module of the proximity
sensor. Special attention must be
paid to this in the case of serial
connections.
Wire-break protection
If one of the supply lines is broken,
the output remains disabled (no
misoperation).
11
SICK8 007 755.0300
DC 3/4-wire sensors
Apart from the oscillator, direct-
current sensors also have an output
amplifier. They are supplied as 3/4-
wire sensors with NO, NC,
complementary or programmable
outputs. Sensors of this type have
short-circuit, reverse-polarity
protection, and power-up pulse
suppression. The residual current is
negligable. A capacitive load of up to
0.15 µF can be connected. These
sensors are supplied as:
- NC, negative-switching (NPN)
- NC, positive-switching (PNP)
- NO, negative-switching (NPN)
- NO, positive-switching (PNP)
- programmable NO/NC,
negative-switching (NPN)
- programmable NO/NC,
positive-switching (PNP)
- complementary NO and NC
negative-switching (NPN)
- complementary NO and NC
positive-switching (PNP)
- free configurable as
NO, negative-switching (NPN)
NO, positive-switching (PNP)
NC, negative-switching (NPN)
NC, positive-switching (PNP)
These points are particularly relevant
in the case of parallel and serial
connections. These sensors are
supplied as:
-normally open
-normally closed
-programmable NO/NC
Serial connection
of 2-wire sensors:
Not recommended
Parallel connection of 2-wire sensors:
In the case of parallel connection, the
residual currents of all proximity
sensors are added together.
Glossary
Electrical
Serial connection of 3-wire sensors:
With series connection, the voltage
drops and the standby delay times of
the individual proximity sensors are
added together.
That is the reason for a reduced load
voltage.
PNP-connection:
Sensor n
Sensor 1
0V
+Ub
Parallel connection of 3-wire sensors:
The LEDs of all proximity sensors light
up if only one sensor is active. It is
therefore advisable to install blocking
diodes in the switching output.
PNP-connection:
+Ub
0V
Sensor 1 Sensor n
AC/DC 2-wire sensors
Apart from the oscillator, alternating
current 2-wire sensors also have a
transistor as an output amplifier.
These sensors are directly operated
in series with the load. As a result, a
small residual current flows across
the load when the sensors are
disabled. In forced-tripping mode, a
drop in voltage also occurs at the
sensor.
Protection class
Sensors not bearing the symbol
must be operated at power sources
which comply with the safety require-
ments for extra-low voltage as per
VDE 100.
L1/+
Sensor 1 Sensor n
N/-
12 SICK 8 007 755.0300
NAMUR sensor to EN 50227
These sensors are 2-wire electric
position encoders which are usually
connected to the control input of a
switching amplifier.
The direct-current source of the
switching amplifier provides the
sensors with power. If metal or
magnets are positioned close to the
sensors, the internal resistance of the
NAMUR sensor changes (constant
distance/current curve, see graph).
The change in internal resistance is
evaluated by the switching amplifier
and converted into a digital signal.
All NAMUR sensors have a
classification for division 1 areas.
They can be used in combination
with Isolating units.
Typical standard operating values for
a control circuit with intrinsic safety
protection:
UN= 8.2 V
Ri=1 KW
Iattenuated < 1.2 mA
Iunattenuated > 2.1 mA
The falling curve from right to left only
applies to inductive sensors. The
curve for magnetic sensors has
exactly the same characteristics, but
ascends from right to left:
Iattenuated > 2.1 mA
Iunattenuated < 1.2 mA
Glossary
Electrical
4.0 mA Magnetic
proximity sensors
3.0 mA
2.1 mA
2.0 mA
1.75 mA
1.55 mA
1.2 mA
1.0 mA
snsns [mm]
Switching current difference
Inductive
proximity sensors
Ds = Switching travel difference
^
DsDs
I [mA]
13
SICK8 007 755.0300
Glossary
Standar ds and conformities
Standards
EN 60 947-1 - IEC 947-1 Low-voltage switchgear; part 1:
DIN VDE 0660 Part 100 General specifications
EN 60 947-5-1 - IEC 947-5-1 Low-voltage switchgear; part 5:
DIN VDE 0660 Part 200 Controllers and switching elements
Section 1: Electromechanical controllers
EN 60 947-5-2 - IEC 947-5-2 Switchgear; low-voltage switchgear;
DIN VDE 0660 Part 208 auxiliary circuit switch; additional specifications for inductive proximity switches
IEC 664 Specification for measuring air and
DIN VDE 0110 creepage distances of electric equipment
EN 60 204-1 - IEC 204-1 Electric components in industrial machines;
DIN VDE 113 Part 1 Part 1: General requirements
DIN VDE 0160 Components in power systems with electronic equipment
EN 60 529 - IEC 529 Enclosure ratings provided by housing (IP code)
EN 50 227 NAMUR - electric position encoder -
direct-current interface for position encoder and switching amplifier
Conformities
Directives for consumer and capital goods enetering the European market
have been established by the EU commission to standardise the European
single market. To indicate fulfilment of these directives, manufacturers attach
the "CE-symbol" to their products.
This symbol also issued by the Underwriters Laboratories bears the letter "L"
("listed". This means that the machine has been granted an individual approval '
with an approval number. This symbol permits the checking of product´s mass
production at any time and without prior notice.
The Canadian operating regulations for electrical plants and components are
subject to the CEC /Canadian Electrical Code) whicg descibes CSA conformity
for all machines. The Canadian Standard Assiciation issues the CSA symbol
after the testing of individual components.
14 SICK 8 007 755.0300
Response curve for inductive
proximity sensors
The specified sensing ranges are
determined in the case of axial
approach along the reference axis of
the sensor.
Radial approach results in a reduction
of the sensing range. The edge of the
switching trigger has only a small
surface area. As a result, less eddy-
current losses occur. The sensor
therefore only reacts if the switching
trigger laterally enters the alternating
field relatively close to the sensing
face. In the case of axial approach,
the full surface of the switching trigger
is exposed to the scattered
electromagnetic field. Axial alignment
therefore provides the maximum sen-
sing range.
Operating Principle
Inductive proximity sensors
Alternating field
Sensing face
Switching amplifierLC oscillating circuit Signal evaluator
Attenuating
material
LC
An inductive proximity sensor
comprises an LC oscillating circuit, a
signal evaluator, and a switching
amplifier.
The coil of this oscillating circuit
generates a high-frequency
electromagnetic alternating field. This
field is emitted at the sensing face of
the sensor.
If attenuating material nears the sen-
sing face, eddy currents are gene-
rated in the case of non-ferrite metals.
In the case of ferromagnetic metals,
hysteresis and eddy-current loss also
occurs.
These losses draw energy from the
oscillating circuit and reduce
oscillation. The signal evaluator
detects this reduction and converts it
into a switching signal.
The terms "attenuated" and
"unattenuated" are used to describe
the two switching states of the
inductive proximity sensors.
Switching trigger
attenuated
unattenuated
U
I
sn
Axial approach direction
Hysteresis
Radial approach
direction
Proximity
sensor
Reliable
operating
range
15
SICK8 007 755.0300
Rated switching trigger
All sensing range measurements
must be performed by axially moving
a standard square measuring plate
made of St37 (1 mm thick) through
the alternating field. The length of the
switching trigger sides is equal to the
diameter of the response area or is
3 sn. The larger value should be
taken.
Reduction factor RM
The specified sensing ranges all relate
to St37. Considerable reductions in
distance sometimes occur in the case
of other materials.
Approximate reference values, which
can vary from type to type:
St37 ( Fe ) 1
Stainless steel ( V2A ) 0.8
Aluminium (solid) 0.45
Copper ( Cu ) 0.4
These correction factors must be
taken into consideration when
selecting actuation elements or when
calibrating to objects made of the
respective alloys.
Glossary
Inductive proximity sensors
When proximity sensors are installed,
the reliable sensing range ( 8 1 % o f sn)
should always be used as the basis.
The exact switching point must be
set by means of fine adjustment.
1.0
0.8
0.4
0
V2A
Fe
Al
Cu
0.45
16 SICK 8 007 755.0300
Flush installation in metal
Proximity sensors for flush installation
are shielded internally around the
ferrite core. As a result, the sensor
can be embedded in the metal up to
the sensing face.
Proximity sensors for flush installation
have a smaller sensing range
compared to proximity sensors for
non-flush installation with the same
shape and design.
Exceeding zone
These sensors with enhanced sen-
sing range are not flush installable in
metal:
Installation Notes
Inductive proximity sensors
Cylindrical design
General installation notes for
cylindrical design for flush and non-
flush installation in metal:
Non-flush installation in metal
With proximity sensors for non-flush
installation, a metal-free zone must be
maintained owing to the scattered
field distribution.
dd
2d
3S
n
2S
n
d
d
Non-flush installation:
Type Exceeding zone
IM12-04B ... 0,1 x d
IM18-08B ... 0,1 x d
IM30-15B ... 0,1 x d
IH06-02B ... 2 mm
Flush installation:
d
d
d
3 Sn
Opposite installation:
8 S
n
17
SICK8 007 755.0300
Cuboidal design
General installation notes for cuboidal
design in metal:
8 x Sn
design X Y Z
IQ40-15B 0 40 0
IQ40-20B 0 40 0
IQ40-20N 0 80 80
IQ40-35N 40 80 80
888
Ø16
Ø24
Ø24
8
design Y
IQ08-02B ... 8
IQ08-04N ... 16
IQ10-03B ... 10
IQ10-06N ... 20
IQ12-03B ... 12
IQ12-06N ... 24
10
12
Z
Z
X
40
Y
in mm
in mm
18 SICK 8 007 755.0300
Selection Table
Inductive proximity sensors
Terminals
Cable
NO
NO/NC
progr./compl.
NC
Housing Page
Connection
type Electr.
config.
Output
function
Switching-
output
Sensing range
sn in mm
PNP
NPN
Connector
Series
IM04
IM05
IM08
IM12
IM18
IM30
IH03
IH04
IH06
IQ05
IQ08
IQ10
IQ12
IQ40
IQ40
IQ80
IM12
IM18
IM30
IM12
IM18
IM30
IH20
IH34
IQ40
IQ80
IM08
IM12
IM18
IM30
Size in mm
M4
M5
M8
M12
M18
M30
Ø3
Ø4
Ø6,5
5x5x25
8x40/8x49
10x28/16x37
12x40/26x49
41x41x121
40x40x66
80x40x105
M12
M18
M30
M12
M18
M30
Ø20
Ø34
41x41x121
80x40x105
M8
M12
M18
M30
Material
Brass
Brass
Brass
Brass
Brass
Brass
Stainless steel
Stainless steel
Stainless steel
Brass
Plastic
Plastic
Plastic
Plastic
Plastic
Plastic
Brass
Brass
Brass
Brass
Brass
Brass
Plastic
Plastic
Plastic
Plastic
Brass
Brass
Brass
Brass
Non flush
2,5/4
4/8
8/12
15/20
4
4
6
6
20
35
60
4
8
15
4
8
15
10
30
20
60
4
8
15
DC 3-w.
DC 3-w.
DC 3-w.
DC 3/4-w.
DC 3/4-w.
DC 3-w.
DC 3-w.
DC 3-w.
DC 3-w.
DC 3-w.
DC 3-w.
DC 3-w.
DC 3-w.
DC 3-w.
DC 3/4-w.
DC 3-w.
DC 2-w.
DC 2-w.
DC 2-w.
AC
AC/DC
AC/DC
AC/DC
AC/DC
AC/DC
AC/DC
NAMUR
NAMUR
NAMUR
NAMUR
20
22
24
30
40
50
56
58
60
64
66
68
70
72
74
76
78
80
82
84
86
88
90
92
94
96
98
100
102
104
Design
Cylinder
with
thread
Barrel,
smooth
Cuboid
Cylinder
with
thread
Cylinder
with
thread
Barrel,
smooth
Cuboid
Cylinder
with
thread
Flush
0,6
0,8
1,5/2
2/4
5/8
10/15
0,6
0,8
1,5/2
0,8
2
3
3
15
15/20
2
5
10
2
5
10
15
1
2
5
10
19
SICK8 007 755.0300
Type Code
Inductive proximity sensors
Character 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Character
1Sensor technology
I Inductive
3/4 Housing shape
03
04
05
06
08
10
12 Diameter
18 or
2 0 edge length of
30 sensing face
34
40
80
2Design
H Barrel
M Cylinder with thread
Q Cuboid
I M 12 - O 2B P S - Z U O
other codes 14
K Short body housing
6/7/8 Sensing range/
installation
B Flush
N Non-flush
02 B 2 mm; flush
04N 4 mm; non-flush
1B5 1.5 mm; flush
2N 5 2.5 mm; non-flush
Connection 13
W Cable, PVC
U Cable, PUR-PVC
P Cable with connector, M8x1
T Connector, M8x1
C Connector, M12x1
K Terminals
Housing material 12
Z Ms, nickel-plated
V Stainless steel
K Plastic
Output 10
SNO
ONC
P Programmable/complementary
N NAMUR
Interface 9
P DC (3/4-wire) PNP
N DC (3/4-wire) NPN
C DC (4-wire) PNP or NPN
D DC (2-wire)
A AC 2-wire
U AC/DC 2-wire
- NAMUR
20 SICK 8 007 755.0300
Features
Can be installed flush
PNP or NPN output
Normally open function
High switching frequency
Short-circuit protection
(pulsed)
Robust brass housing,
nickel-plated with fine thread
M4 x 0.5 mm
Cable
Enclosure rating IP 67
LED status indicator
Connection diagram
Inductive proximity sensors
IM 04 series, sensing range 0.6 mm
DC 3-wir e, miniature metal housing
Dimensions in mm
bn
bk
bu
PNP
-
DC
+
Wire colour Assignement
bn brown + V DC
bk black NO
bu blue - V DC
LED Ø 2.6
M4x0.5
16
19
22
6
bn
bk
bu
NPN
-
DC
+
Miniature series
21
SICK8 007 755.0300
Electrical and mechanical data
Selection table
Operating voltage Ub
Ripple Upp
Voltage drop Ud
(at Ia = 50 mA)
Power consumption
(without load)
Continuous current Ia
Time delay before
availability tv
Hysteresis H typ.
Repeatability R
(Ub and Ta constant)
Temperature drift
EMC
10 ... 30 V DC
20% of Ub
0.6 V max.
10 mA
100 mA
10 ms
10% of sr
2%
± 10% of sr
to EN 60 947-5-2
Short-circuit protection
(pulsed)
Reverse polarity protection
Power-up pulse suppression
Enclosure rating to EN 60529
Shock and vibration
stress
Ambient temperature Ta
Housing material
Tightening torque
Connection cable
yes
yes
yes
IP 67
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 70 °C
Brass, nickel-plated,
plastic
0.8 Nm
PUR, 3 x 0.055 mm2
0,6
0,6
Sensing
range sn
mm
Installation
in metal Connection Order number
PNP
NPN
Switching
output TypeOutput
function Switching
frequency f
in Hz
2000
2000 Cable 2 m
Cable 2 m IM04-0B6PS-ZU1
IM04-0B6NS-ZU1 6020145
6020146
Normaly closed function available on request
Inductive proximity sensors, IM 04 series, DC
22 SICK 8 007 755.0300
Features
Can be installed flush
PNP or NPN output
Normally open function
High switching frequency
Short-circuit protection
(pulsed)
Robust brass housing,
nickel-plated with fine thread
M5 x 0.5 mm
Cable or Connector
Enclosure rating IP 67
LED status indicator
Accessories
Round connectors Connection diagram
Inductive proximity sensors
IM 05 series, sensing range 0.8 mm
DC 3-wir e, miniature metal housing
Dimensions in mm
1
4
3
bn
bk
bu
PNP
-
DC
+
3
4
1
Wire colour Contact Assignment
bn brown 1 + V DC
bk black 4 NO
bu blue 3 - V DC
1
4
3
bn
bk
bu
NPN
-
DC
+
25
M5x0.5
LED
7
18
20
Ø 3.5
LED
7
M5x0.5
Ø 6.5
M8x1
18
23 38
Miniature series
23
SICK8 007 755.0300
Electrical and mechanical data
Selection table
Operating voltage Ub
Ripple Upp
Voltage drop Ud
(at Ia = 200 mA)
Power consumption
(without load)
Continuous current Ia
Time delay before
availability tv
Hysteresis H typ.
Repeatability R
(Ub and Ta constant)
Temperature drift
EMC
10 ... 30 V DC
20% of Ub
2.0 V max.
10 mA
200 mA
10 ms
10% of sr
1,5%
± 10% of sr
to EN 60 947-5-2
Short-circuit protection
(pulsed)
Reverse polarity protection
Power-up pulse suppression
Enclosure rating to EN 60529
Shock and vibration
stress
Ambient temperature Ta
Housing material
Tightening torque
Connection cable
yes
yes
yes
IP 67
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 70 °C
Brass, nickel-plated,
plastic
1.5 Nm
PVC, 3 x 0.14 mm2
0.8
0.8
0.8
0.8
Sensing
range sn
mm
Installation
in metall Connection Order number
PNP
NPN
PNP
NPN
Switching
output TypeOutput
function Switching
frequency f
in Hz
5000
5000
5000
5000
Cable 2 m
Cable 2 m
Connector M8 x 1
Connector M8 x 1
IM05-0B8PS-ZW1
IM05-0B8NS-ZW1
IM05-0B8PS-ZT1
IM05-0B8NS-ZT1
6011591
6020155
6020110
6020158
Normaly closed function available on request
Inductive proximity sensors, IM 05 series, DC
24 SICK 8 007 755.0300
Connection diagram
Inductive proximity sensors
IM 08 series, sensing range 1.5 / 2.5 mm
DC 3-wir e, metal housing
Features
Can be installed flush or
non-flush in metal
PNP or NPN output
Normally open/
normally closed function
High switching frequency
Short-circuit protection
(pulsed)
Robust brass housing,
nickel-plated with fine thread
M8 x 1 mm
Cable or connector
Enclosure rating IP 67
LED status indicator
Accessories
Round connectors
Dimensions in mm
1
4
3
bn
bk
bu
PNP
-
DC
+1
4
3
bn
bk
bu
NPN
-
DC
+
1
2/4
3
bn
bk
bu
+
DC
-
1
2/4
3
bn
bk
bu
+
DC
-
PNP NPN
1
3
4
2
3
4
1
M8
M12
Wire colour Contact M8 Contact M12 Assignment
bn brown 1 1 + V DC
bk black 4 2/4 NC/NO
bu blue 3 3 - V DC
Standard series
13
M8x1
M8x1
M8x1
M8x1
M8x1
M8x1
4.8
4.8
LED, 4x90°
50
35.3
M8x1
13 LED, 4x90°
50
31.3
M8x1
4
13
13
13 M12x1
38 60
M12x1
13
434 60
40.2
36.2
40.2
LED, 4x90°
LED, 4x90°
LED
LED
25
SICK8 007 755.0300
Electrical and mechanical data
Operating voltage Ub
Ripple Upp
Voltage drop Ud
(at Ia max.)
Power consumption
(without load)
Continuous current Ia
Time delay before
availability tv
Hysteresis H
Repeatability R
(Ub and Ta constant)
Temperature drift
EMC
10 ... 30 V DC
10%
1.2 V
20 mA
200 mA
100 ms
2% - 10% of sr
2% of sr
± 10% of sr
to EN 60 947-5-2
Short-circuit protection
(pulsed)
Reverse polarity protection
Power-up pulse suppression
Enclosure rating to EN 60529
Shock and vibration
stress
Ambient temperature Ta
Housing material
Tightening torque
Connection cable
yes
yes
yes
IP 67
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 70 °C
Brass, nickel-plated,
plastic
4 Nm
PVC, 3 x 0.14 mm2
Selection table
1.5
1.5
1.5
1.5
Sensing
range sr
mm
Installation
in metal Connection Order number
PNP
NPN
PNP
NPN
Switching
output TypeOutput
function Switching
frequency f
in Hz
3000
3000
3000
3000
Cable 2 m
Cable 2 m
Cable 2 m
Cable 2 m
IM08-1B5PS-ZW1
IM08-1B5NS-ZW1
IM08-1B5PO-ZW1
IM08-1B5NO-ZW1
6020215
6020216
6020217
6020218
1.5
1.5
1.5
PNP
NPN
PNP
3000
3000
3000
Connector M8 x 1 mm
Connector M8 x 1 mm
Connector M8 x 1 mm
IM08-1B5PS-ZT1
IM08-1B5NS-ZT1
IM08-1B5PO-ZT1
6020219
6020220
6020221
1.5
1.5 PNP
NPN 3000
3000
Connector M12 x 1 mm
Connector M12 x 1 mm
IM08-1B5PS-ZC1
IM08-1B5NS-ZC1 6020223
6020224
2.5
2.5 PNP
NPN 2500
2500 Cable 2 m
Cable 2 m IM08-2N5PS-ZW1
IM08-2N5NS-ZW1 6020227
6020228
2.5
2.5 PNP
NPN 2500
2500
Connector M8 x 1 mm
Connector M8 x 1 mm
IM08-2N5PS-ZT1
IM08-2N5NS-ZT1 6020231
6020232
2.5
2.5 PNP
NPN 2500
2500
Connector M12 x 1 mm
Connector M12 x 1 mm
IM08-2N5PS-ZC1
IM08-2N5NS-ZC1 6020235
6020236
Inductive proximity sensors, IM 08 series, DC
26 SICK 8 007 755.0300
Features
Can be installed flush
PNP or NPN output
Normally open function
High switching frequency
Short-circuit protection
(pulsed)
Robust brass housing,
nickel-plated with fine thread
M8 x 1 mm
Cable or Connector
Enclosure rating IP 67
LED status indicator
Accessories
Round connectors Connection diagram
Inductive proximity sensors
IM 08 series, sensing range 1.5 mm
DC 3-wire, metal housing
Dimensions in mm
1
4
3
bn
bk
bu
PNP
-
DC
+
3
4
1
Wire colour Contact Assignment
bn brown 1 + V DC
bk black 4 NO
bu blue 3 - V DC
Miniature series
1
4
3
bn
bk
bu
NPN
-
DC
+
M8x1
M8x1
LED
Ø 3,5
16
M8x1
12 29
13
13 LED, 4x90°
27
SICK8 007 755.0300
Electrical and mechanical data
Selection table
Operating voltage Ub
Ripple Upp
Voltage drop Ud
(at Ia= 200 mA)
Power consumption
(without load)
Continuous current Ia
Time delay before
availability tv
Hysteresis H
Repeatability R
(Ub and Ta constant)
Temperature drift
EMC
10 ... 30 V DC
20% of Ub
2.0 V max.
10 mA
200 mA
10 ms
10% of sr
5% of sr
± 10% of sr
to EN 60 947-5-2
Short-circuit protection
(pulsed)
Reverse polarity protection
Power-up pulse suppression
Enclosure rating to EN 60529
Shock and vibration
stress
Ambient temperature Ta
Housing material
Tightening torque
Connection cable
yes
yes
yes
IP 67
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 70 °C
Brass, nickel-plated,
plastic
4 Nm
PVC, 3 x 0.14 mm2
Sensing
range sn
mm
Installation
in metal Connection Order numberSwitching
output TypeOutput
function Switching
frequency f
in Hz
1.5
1.5
1.5
1.5
PNP
NPN
PNP
NPN
5000
5000
5000
5000
Cable 2 m
Cable 2 m
Connector M8 x 1 mm
Connector M8 x 1 mm
IM08-1B5PS-ZWK
IM08-1B5NS-ZWK
IM08-1B5PS-ZTK
IM08-1B5NS-ZTK
6020111
6020173
6020112
6020176
Normaly closed function available on request
Inductive proximity sensors, IM 08 series, DC
28 SICK 8 007 755.0300
Features
Enhanced sensing range
Can be installed flush or
non-flush in metal
PNP or NPN output
Normally open/
normally closed function
High switching frequency
Short-circuit protection
(pulsed)
Robust brass housing,
nickel-plated with fine thread
M8 x 1 mm
Cable or connector
Enclosure rating IP 67
LED status indicator
Accessories
Round connectors
Connection diagram
Inductive proximity sensors
IM 08 series, sensing range 2 / 4 mm
DC 3-wire, metal housing
1
4
3
bn
bk
bu
1
4
3
bn
bk
bu
PNP
PNP +
DC
-
-
DC
+1
4
3
bn
bk
bu
1
4
3
bn
bk
bu
NPN
NPN +
DC
-
-
DC
+
Wire colour Contact Assignment
bn brown 1 + V DC
bk black 4 NC/NO
bu blue 3 - V DC
Dimensions in mm
4
3
1
Advanced series
M8x1
M8x1
M8x1
M8x1
13
4
40.2 4.8
13
36.2
40.2
13
4.8
LED, 4x90°
M8x1
LED, 4x90°
M8x1
50
35.3
50
31.3
13
LED
LED
29
SICK8 007 755.0300
Electrical and mechanical data
Selection table
Operating voltage Ub
Ripple Upp
Voltage drop Ud
(at Ia max.)
Power consumption
(without load)
Continuous current Ia
Time delay before
availability tv
Hysteresis H
Repeatability R
(Ub and Ta constant)
Temperature drift
EMC
10 ... 30 V DC
10% of Ub
1.2 V
20 mA
200 mA
100 ms
2% - 15% of sr
5% of sr
± 10% of sr
to EN 60 947-5-2
Short-circuit protection
(pulsed)
Reverse polarity protection
Power-up pulse suppression
Enclosure rating to EN 60529
Shock and vibration
stress
Ambient temperature Ta
Housing material
Tightening torque
Connection cable
yes
yes
yes
IP 67
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 70 °C
Brass, nickel-plated,
plastic
4 Nm
PVC, 3 x 0.14 mm2
2
2
2
Sensing
range sn
mm
Installation
in metal Connection Order number
PNP
NPN
PNP
Switching
output TypeOutput
function Switching
frequency f
in Hz
3000
3000
3000
Cable 2 m
Cable 2 m
Cable 2 m
IM08-02BPS-ZW1
IM08-02BNS-ZW1
IM08-02BPO-ZW1
7900001
7900002
7900003
2
2
2
2
PNP
NPN
PNP
NPN
3000
3000
3000
3000
Connector M8 x 1 mm
Connector M8 x 1 mm
Connector M8 x 1 mm
Connector M8 x 1 mm
IM08-02BPS-ZT1
IM08-02BNS-ZT1
IM08-02BPO-ZT1
IM08-02BNO-ZT1
7900005
7900006
7900007
7900008
4
4
4
PNP
NPN
PNP
3000
3000
3000
Cable 2 m
Cable 2 m
Cable 2 m
IM08-04NPS-ZW1
IM08-04NNS-ZW1
IM08-04NPO-ZW1
7900009
7900010
7900011
4
4
4
4
PNP
NPN
PNP
NPN
3000
3000
3000
3000
Connector M8 x 1 mm
Connector M8 x 1 mm
Connector M8 x 1 mm
Connector M8 x 1 mm
IM08-04NPS-ZT1
IM08-04NNS-ZT1
IM08-04NPO-ZT1
IM08-04NNO-ZT1
7900013
7900014
7900015
7900016
Inductive proximity sensors, IM 08 series, DC
30 SICK 8 007 755.0300
Inductive proximity sensors
IM 12 series, sensing range 2 / 4 mm
DC 3-wir e, metal housing
Features
Can be installed flush or
non-flush in metal
PNP or NPN output
Normally open/
normally closed function
Short-circuit protection
(pulsed)
Robust brass housing,
nickel-plated with fine thread
M12 x 1 mm
Cable or connector
Enclosure rating IP 67
LED status indicator
Accessories
Round connectors
Mounting bracket Connection diagram
Dimensions in mm
1
4
3
bn
bk
bu
PNP
-
DC
+1
4
3
bn
bk
bu
NPN
-
DC
+
1
2/4
3
bn
bk
bu
PNP +
DC
-
1
2/4
3
bn
bk
bu
NPN +
DC
-
2
1
3
3
1
4
4
M12
M8
Wire colour Contact M8 Contact M12 Assignment
bn brown 1 1 + V DC
bk black 4 2/4 NC/NO
bu blue 3 3 - V DC
Standard series
M12x1
17
535
50
M12x1
17
40
M12x1
17
LED, 4x90°
50
38 65
5
17
65
43
M12x1
LED, 4x90°
5
M12x1
M12x1
17
17
LED, 4x90°
LED, 4x90°
M12x1
M12x1
10
60.5
60.5
43
38
LED
LED
31
SICK8 007 755.0300
Operating voltage Ub
Ripple Upp
Voltage drop Ud
(at Ia max.)
Power consumption
(without load)
Continuous current Ia
Time delay before
availability tv
Hysteresis H
Repeatability R
(Ub and Ta constant)
Temperature drift
EMC
10 ... 30 V DC
10%
1.2 V
20 mA
200 mA
100 ms
2% - 10% of sr
2% of sr
± 10% of sr
to prEN 60 947-5-2
Short-circuit protection
(pulsed)
Reverse polarity protection
Power-up pulse suppression
Enclosure rating to EN 60529
Shock and vibration
stress
Ambient temperature Ta
Housing material
Tightening torque
Connection cable
yes
yes
yes
IP 67
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 70 °C
Brass, nickel-plated,
plastic
10 Nm
PVC, 3 x 0.22 mm2
Electrical and mechanical data
2
2
2
2
PNP
NPN
PNP
NPN
2000
2000
2000
2000
Cable 2 m
Cable 2 m
Cable 2 m
Cable 2 m
IM12-02BPS-ZW1
IM12-02BNS-ZW1
IM12-02BPO-ZW1
IM12-02BNO-ZW1
6011963
6011964
6011965
6011966
2
2PNP
NPN 2000
2000
Connector M8 x 1 mm
Connector M8 x 1 mm
IM12-02BPS-ZT1
IM12-02BNS-ZT1 6011967
6011968
Selection table
Sensing
range sn
mm
Installation
in metal Connection Order numberSwitching
output TypeOutput
function Switching
frequency f
in Hz
2
2
2
2
PNP
NPN
PNP
NPN
2000
2000
2000
2000
Connector M12 x 1 mm
Connector M12 x 1 mm
Connector M12 x 1 mm
Connector M12 x 1 mm
IM12-02BPS-ZC1
IM12-02BNS-ZC1
IM12-02BPO-ZC1
IM12-02BNO-ZC1
6011971
6011972
6011973
6011974
4
4
4
PNP
NPN
PNP
2000
2000
2000
Cable 2 m
Cable 2 m
Cable 2 m
IM12-04NPS-ZW1
IM12-04NNS-ZW1
IM12-04NPO-ZW1
6011975
6011976
6011977
4
4PNP
NPN 2000
2000
Connector M8 x 1 mm
Connector M8 x 1 mm
IM12-04NPS-ZT1
IM12-04NNS-ZT1 6011979
6011980
4
4
4
PNP
NPN
PNP
2000
2000
2000
Connector M12 x 1 mm
Connector M12 x 1 mm
Connector M12 x 1 mm
IM12-04NPS-ZC1
IM12-04NNS-ZC1
IM12-04NPO-ZC1
6011983
6011984
6011985
Inductive proximity sensors, IM 12 series, DC
32 SICK 8 007 755.0300
Inductive proximity sensors
IM 12 series, sensing range 2 / 4 mm
DC 3-wir e, metal housing
Connection diagram
2
1
4
3
Features
Can be installed flush or
non-flush in metal
PNP or NPN output
Normally open function
High switching frequency
Short-circuit protection
(pulsed)
Robust brass housing,
nickel-plated with fine thread
M12 x 1 mm
Cable or connector
Enclosure rating IP 67
LED status indicator
Accessories
Round connectors
Mounting bracket
Dimensions in mm
Short version
17
17
17
17
30
35
35
527
32
M12x1 M12x1 M12x1 M12x1
LED, 4x90°
45
45
LED, 4x90°
LED
LED
M12x1
M12x1
1
4
3
bn
bk
bu
PNP
-
DC
+
1
4
3
bn
bk
bu
NPN
-
DC
+
Wire colour Contact Assignment
bn brown 1 + V DC
bk black 4 NO
bu blue 3 - V DC
33
SICK8 007 755.0300
Electrical and mechanical data
Selection table
Operating voltage Ub
Ripple Upp
Voltage drop Ud
(at Ia max.)
Power consumption
(without load)
Continuous current Ia
Time delay before
availability tv
Hysteresis H
Repeatability R
(Ub and Ta constant)
Temperature drift
EMC
10 ... 30 V DC
10% of Ub
1.5 V
10 mA
300 mA
2 ms
1% - 10% of sr
1% of sr
± 10% of sr
to EN 60 947-5-2
Wire-break protection
Short-circuit protection
(pulsed)
Reverse polarity protection
Power-up pulse protection
Enclosure rating to EN 60529
Shock and vibration
stress
Ambient temperature Ta
Housing material
Tightening torque
Connection cable
yes
yes
yes
yes
IP 67
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 75 °C
Brass, nickel-plated,
plastic
7.0 Nm
PUR-PVC, 3 x 0.25 mm2
2
2
2
2
Sensing
range sn
mm
Installation
in metal Connection Order number
PNP
NPN
PNP
NPN
Switching
output TypeOutput
function Switching
frequency f
in Hz
2000
2000
2000
2000
Cable 2 m
Cable 2 m
Connector M12 x 1 mm
Connector M12 x 1 mm
IM12-02BPS-ZUK
IM12-02BNS-ZUK
IM12-02BPS-ZCK
IM12-02BNS-ZCK
1017426
1017438
1017428
1017440
4
4
4
4
PNP
NPN
PNP
NPN
2000
2000
2000
2000
Cable 2 m
Cable 2 m
Connector M12 x 1 mm
Connector M12 x 1 mm
IM12-04NPS-ZUK
IM12-04NNS-ZUK
IM12-04NPS-ZCK
IM12-04NNS-ZCK
1017427
1017439
1017429
1017441
Inductive proximity sensors, IM 12 series, DC
34 SICK 8 007 755.0300
Inductive proximity sensors
IM 12 series, sensing range 4 / 8 mm
DC 3-wire, metal housing
Features
Enhanced sensing range
Can be installed flush or
non-flush in metal
PNP or NPN output
Normally open/
normally closed function
High switching frequency
Short-circuit protection
(pulsed)
Robust brass housing,
nickel-plated with fine thread
M12 x 1 mm
Cable or connector
Enclosure rating IP 67
LED status indicator
Accessories
Round connectors
Mounting bracket
Wire colour Contact Assignment
bn brown 1 + V DC
bk black 2/4 NC/NO
bu blue 3 - V DC
Connection diagram
1
4
3
bn
bk
bu
1
2
3
bn
bk
bu
PNP
PNP +
DC
-
-
DC
+1
4
3
bn
bk
bu
1
2
3
bn
bk
bu
NPN
NPN +
DC
-
-
DC
+
2
1
4
3
Dimensions in mm
Advanced series
M12x1
17
35
50 10
5
M12x1
M12x1
M12x1
5
65
43 LED, 4x90°
LED, 4x90°
17
17
17
50
40
38 65
M12x1
M12x1
LED
LED
35
SICK8 007 755.0300
Electrical and mechanical data
Selection table
Operating voltage Ub
Ripple Upp
Voltage drop Ud
(at Ia max.)
Power consumption
(without load)
Continuous current Ia
Time delay before
availability tv
Hysteresis H
Repeatability R
(Ub and Ta constant)
Temperature drift
EMC
10 ... 30 V DC
10% of Ub
1.2 V
10 mA
200 mA
100 ms
1% - 15% of sr
5% of sr
± 10% of sr
to EN 60 947-5-2
Short-circuit protection
(pulsed)
Reverse polarity protection
Power-up pulse suppression
Enclosure rating to EN 60529
Shock and vibration
stress
Ambient temperature Ta
Housing material
Tightening torque
Connection cable
yes
yes
yes
IP 67
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 70 °C
Brass, nickel-plated,
plastic
10 Nm
PVC, 3 x 0.22 mm2
4
4
4
Sensing
range sn
mm
Installation
in metal Connection Order number
PNP
NPN
PNP
Switching
output TypeOutput
function Switching
frequency f
in Hz
1000
1000
1000
Cable 2 m
Cable 2 m
Cable 2 m
IM12-04BPS-ZW1
IM12-04BNS-ZW1
IM12-04BPO-ZW1
7900033
7900034
7900035
4
4
4
PNP
NPN
PNP
1000
1000
1000
Connector M12 x 1 mm
Connector M12 x 1 mm
Connector M12 x 1 mm
IM12-04BPS-ZC1
IM12-04BNS-ZC1
IM12-04BPO-ZC1
7900037
7900038
7900039
8
8
8
8
PNP
NPN
PNP
NPN
1000
1000
1000
1000
Cable 2 m
Cable 2 m
Cable 2 m
Cable 2 m
IM12-08NPS-ZW1
IM12-08NNS-ZW1
IM12-08NPO-ZW1
IM12-08NNO-ZW1
7900041
7900042
7900043
7900044
8
8
8
PNP
NPN
PNP
1000
1000
1000
Connector M12 x 1 mm
Connector M12 x 1 mm
Connector M12 x 1 mm
IM12-08NPS-ZC1
IM12-08NNS-ZC1
IM12-08NPO-ZC1
7900045
7900046
7900047
Inductive proximity sensors, IM 12 series, DC
* see installation notes
*
*
*
*
*
*
SICK
36 8 007 755.0300
Inductive proximity sensors
IM 12 series, sensing range 2 / 4 mm
DC 4-wir e, metal housing
M12x1
Connection diagram
PNP NPN
2
1
4
3
6
65
LED
M12x1
M12x1
M12x1
39 65
LED
1+1+
Wire colour Contact Assignment
bn brown 1 + V DC
wh white 2 NC
bu blue 3 - V DC
bk black 4 NO
44 22
33
--
DC DC
33
17
17
ø 12 .7 ø 12.7
Dimensions in mm
Features
For harsh environment,
resistant to most cutting oils
Enclosure rating IP 68
Can be installed flush or
non-flush in metal
PNP or NPN output
Complementary output
function
Short-circuit protection
(pulsed)
Robust brass housing,
nickel-plated with fine thread
M12 x 1 mm
Internal enclosure housing
in technopolymer
Connector
LED status indicator
(NO function)
Accessories
Round connectors
Mounting bracket comple-
mentary comple-
mentary
For harsh environment
SICK 37
8 007 755.0300
Selection table
Sensing
range sn
mm
Installation
in metal Connection Order number
Switching
output TypeOutput
function Switching
frequency f
in Hz
2
2
PNP
NPN
complementary
2000
2000
IM12-02BPP-ZC1
IM12-02BNP-ZC1
7902923
7902924
4
4
PNP
NPN
complementary
complementary
complementary
2000
2000
IM12-04NPP-ZC1
IM12-04NNP-ZC1
7902925
7902926
Operating voltage Ub
Ripple Upp
Voltage drop Ud
(at Ia max.)
Power consumption
(without load)
Continuous current Ia
Time delay before
availability tv
Hysteresis H
Repeatability R
(Ub and Ta constant)
Temperature drift
EMC
10 ... 30 V DC
10%
1.2 V
20 mA
100 mA
100 ms
2% - 10% of sr
5% of sr
± 10% of sr
to EN 60 947-5-2
Short-circuit protection
(pulsed)
Reverse polarity protection
Power-up pulse suppression
Enclosure rating
Shock and vibration
stress
Ambient temperature Ta
Housing material
Tightening torque
yes
yes
yes
IP 68
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 70 °C
Brass, nickel-plated,
plastic
10 Nm
Electrical and mechanical data
Connector
M12 x 1 mm
Connector
M12 x 1 mm
Connector
M12 x 1 mm
Connector
M12 x 1 mm
Inductive proximity sensors, IM 12 series, DC
SICK
38 8 007 755.0300
Inductive proximity sensors
IM 12 series, sensing range 2 / 4 mm
DC 4-wir e, metal housing
Features
Free configurable output
functions in one sensor
PNP / NO, PNP / NC
NPN / NO, NPN / NC
Can be installed flush or
non-flush in metal
Short-circuit protection
Robust brass housing,
nickel-plated with fine thread
M12 x 1 mm
Cable or connector
Enclosure rating IP 67
LED status indicator
(NO function)
Accessories
Round connectors
Mounting bracket
Connection diagram
1
4
bn
bk
PNP
PNP
DC
-
-
DC
+1
4
bn
bk
NPN
NPN
DC
-
DC
+
2wh
3bu 3bu
2wh
++
-
3
4
bu
bk
3
4
bu
bk
2wh
1bn 1bn
2wh
Wire colour Contact configurable output function
bn brown 1 +V DC -V DC +V DC -V DC
wh white 2 +V DC +V DC NO NC
bu blue 3 - V DC +V DC -V DC +V DC
bk black 4 NO NC -V DC -V DC
NPN
PNP 2
1
4
3
Dimensions in mm
Multitalents
M12x1
M12x1
M12x1
M12x1
545
60
17
17
50
60
M12x1
548
75
M12x1
53 75
17
17
LED, 4x90°
LED, 4x90°
LED
LED
SICK 39
8 007 755.0300
Selection table
Sensing
range sn
mm
Installation
in metal Connection Order number
PNP/NPN
config.
Switching
output TypeOutput
function Switching
frequency f
in Hz
10002 Cable 2 m IM12-02BCP-ZW1 7902927
PNP/NPN
config. 10002IM12-02BCP-ZC1 7902928
PNP/NPN
config. 10004 Cable 2 m IM12-04NCP-ZW1 7902929
PNP/NPN
config. 10004IM12-04NCP-ZC1 7902930
config.
config.
config.
config.
Operating voltage Ub
Ripple Upp
Voltage drop Ud
(at Ia max.)
Power consumption
(without load)
Continuous current Ia
Time delay before
availability tv
Hysteresis H
Repeatability R
(Ub and Ta constant)
Temperature drift
EMC
10 ... 30 V DC
10%
1.2 V
30 mA
100 mA
250 ms
2% - 10% of sr
5% of sr
± 10% of sr
to EN 60 947-5-2
Short-circuit protection
Reverse polarity protection
Power-up pulse suppression
Enclosure rating to EN 60529
Shock and vibration
stress
Ambient temperature Ta
Housing material
Tightening torque
Connection cable
yes
yes
yes
IP 67
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 70 °C
Brass, nickel-plated,
plastic
15 Nm
PVC, 4 x 0.22 mm2
Electrical and mechanical data
Connector
M12 x 1 mm
Connector
M12 x 1 mm
Inductive proximity sensors, IM 12 series, DC
40 SICK 8 007 755.0300
Inductive proximity sensors
IM 18 series, sensing range 5 / 8 mm
DC 3-wir e, metal housing
Wire colour Contact Assignment
bn brown 1 + V DC
bk black 2/4 NC/NO
bu blue 3 - V DC
Connection diagram
2
1
4
3
Dimensions in mm
1
4
3
bn
bk
bu
1
2
3
bn
bk
bu
PNP
PNP +
DC
-
-
DC
+1
4
3
bn
bk
bu
1
2
3
bn
bk
bu
NPN
NPN +
DC
-
-
DC
+
Features
Can be installed flush or
non-flush in metal
PNP or NPN output
Normally open/
normally closed function
Short-circuit protection
(pulsed)
Robust brass housing,
nickel-plated with fine thread
M18 x 1 mm
Cable or connector
Enclosure rating IP 67
LED status indicator
Accessories
Round connectors
Mounting bracket
Standard series
M18x1
M18x1
M18x1
M18x1
850
24
8
24
64
24
4050
64
32
24
LED, 4x90°
M12x1
40
M12x1
LED, 4x90°
48
LED
LED
41
SICK8 007 755.0300
Selection table
Operating voltage Ub
Ripple Upp
Voltage drop Ud
(at Ia max.)
Power consumption
(without load)
Continuous current Ia
Time delay before
availability tv
Hysteresis H
Repeatability R
(Ub and Ta constant)
Temperature drift
EMC
10 ... 30 V DC
10%
1 V
20 mA
400 mA
100 ms
2% - 10% of sr
2% of sr
± 10% of sr
to EN 60 947-5-2
Short-circuit protection
(pulsed)
Reverse polarity protection
Power-up pulse suppression
Enclosure rating to EN 40050
Shock and vibration
stress
Ambient temperature Ta
Housing material
Tightening torque
Connection cable
yes
yes
yes
IP 67
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 70 °C
Brass, nickel-plated,
plastic
30 Nm
PVC, 3 x 0.34 mm2
Electrical and mechanical data
5
5
5
PNP
NPN
PNP
600
600
600
Cable 2 m
Cable 2 m
Cable 2 m
IM18-05BPS-ZW1
IM18-05BNS-ZW1
IM18-05BPO-ZW1
6011987
6011988
6011989
Sensing
range sn
mm
Installation
in metal Connection Order numberSwitching
output TypeSwitching
function Switching
frequency f
in Hz
5
5
5
PNP
NPN
PNP
600
600
600
Connector M12 x 1 mm
Connector M12 x 1 mm
Connector M12 x 1 mm
IM18-05BPS-ZC1
IM18-05BNS-ZC1
IM18-05BPO-ZC1
6011991
6011992
6011993
8
8
8
PNP
NPN
NPN
600
600
600
Cable 2 m
Cable 2 m
Cable 2 m
IM18-08NPS-ZW1
IM18-08NNS-ZW1
IM18-08NNO-ZW1
6011995
6011996
6011998
Inductive proximity sensors, IM 18 series, DC
8
8
8
PNP
NPN
PNP
600
600
600
Connector M12 x 1 mm
Connector M12 x 1 mm
Connector M12 x 1 mm
IM18-08NPS-ZC1
IM18-08NNS-ZC1
IM18-08NPO-ZC1
6011999
6012000
6012001
42 SICK 8 007 755.0300
Inductive proximity sensors
IM 18 series, sensing range 5 / 8 mm
DC 3-wire, metal housing
Features
Can be installed flush or
non-flush in metal
PNP or NPN output
Normally open function
Short-circuit protection
(pulsed)
Robust brass housing,
nickel-plated with fine thread
M18 x 1 mm
Cable and connector
Enclosure rating IP 67
LED status indicator
Accessories
Round connectors
Mounting bracket
Wire colour Contact Assignment
bn brown 1 + V DC
bk black 4 NO
bu blue 3 - V DC
Connection diagram
2
1
4
3
Dimensions in mm
40
30
M18x1 M18x1 M18x1 M18x1
40
45
45
10 22
32
24
LED, 4x90°
LED, 4x90°
24
24
24
LED
LED
M12x1
M12x1
Short version
1
4
3
bn
bk
bu
PNP
-
DC
+
1
4
3
bn
bk
bu
NPN
-
DC
+
43
SICK8 007 755.0300
Electrical and mechanical data
Selection table
Operating voltage Ub
Ripple Upp
Voltage drop Ud
(at Ia max.)
Power consumption
(without load)
Continuous current Ia
Time delay before
availability tv
Hysteresis H
Repeatability R
(Ub and Ta constant)
Temperature drift
EMC
10 ... 30 V DC
10% of Ub
1.5 V
10 mA
300 mA
10 ms
2% - 10% of sr
2% of sr
± 10% of sr
to EN 60 947-5-2
Wire-break protection
Short-circuit protection
(pulsed)
Reverse polarity protection
Power-up pulse suppression
Enclosure rating to EN 60529
Shock and vibration
stress
Ambient temperature Ta
Housing material
Tightening torque
Connection cable
yes
yes
yes
yes
IP 67
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 75 °C
Brass, nickel-plated,
plastic
25 Nm
PUR-PVC, 3 x 0.25 mm2
5
5
5
5
Sensing
range sn
mm
Installation
in metal Connection Order number
PNP
NPN
PNP
NPN
Switching
output TypeSwitching
function Switching
frequency f
in Hz
1000
1000
1000
1000
Cable 2 m
Cable 2 m
Connector M12 x 1 mm
Connector M12 x 1 mm
IM18-05BPS-ZUK
IM18-05BNS-ZUK
IM18-05BPS-ZCK
IM18-05BNS-ZCK
1017430
1017442
1017432
1017444
8
8
8
8
PNP
NPN
PNP
NPN
1000
1000
1000
1000
Cable 2 m
Cable 2 m
Connector M12 x 1 mm
Connector M12 x 1 mm
IM18-08NPS-ZUK
IM18-08NNS-ZUK
IM18-08NPS-ZCK
IM18-08NNS-ZCK
1017431
1017443
1017433
1017445
Inductive proximity sensors, IM 18 series, DC
44 SICK 8 007 755.0300
Inductive proximity sensors
IM 18 series, sensing range 8 / 12 mm
DC 3-wire, metal housing
Features
Enhanced sensing range
Can be installed flush or
non-flush in metal
PNP or NPN output
Normally open/
normally closed function
High switching frequency
Short-circuit protection
(pulsed)
Robust brass housing,
nickel-plated with fine thread
M18 x 1 mm
Cable and connector
Enclosure rating IP 67
LED status indicator
Accessories
Round connectors
Mounting bracket
Wire colour Contact Assignment
bn brown 1 + V DC
bk black 2/4 NC/NO
bu blue 3 - V DC
Connection diagram
1
4
3
bn
bk
bu
1
2
3
bn
bk
bu
PNP
PNP +
DC
-
-
DC
+1
4
3
bn
bk
bu
1
2
3
bn
bk
bu
NPN
NPN +
DC
-
-
DC
+
2
1
4
3
Dimensions in mm
Advanced series
M18x1
M18x1
M18x1
M18x1
850
24
8
24
64
24
40
50
64
32
LED
24 LED
LED, 4x90°
M12x1
40
M12x1
LED, 4x90°
48
45
SICK8 007 755.0300
Electrical and mechanical data
Selection table
Operating voltage Ub
Ripple Upp
Voltage drop Ud
(at Ia max.)
Power consumption
(without load)
Continuous current Ia
Time delay before
availability tv
Hysteresis H
Repeatability R
(Ub and Ta constant)
Temperature drift
EMC
10 ... 30 V DC
10% of Ub
1 V
10 mA
400 mA
100 ms
2% - 15% of sr
5% of sr
± 10% of sr
to EN 60 947-5-2
Short-circuit protection
(pulsed)
Reverse polarity protection
Power-up pulse suppression
Enclosure rating to EN 60529
Shock and vibration
stress
Ambient temperature Ta
Housing material
Tightening torque
Connection cable
yes
yes
yes
IP 67
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 70 °C
Brass, nickel-plated,
plastic
30 Nm
PVC, 3 x 0.34 mm2
8
8
Sensing
range sn
mm
Installation
in metal Connection Order number
PNP
NPN
Switching
output TypeOutput
function Switching
frequency f
in Hz
300
300 Cable 2 m
Cable 2 m IM18-08BPS-ZW1
IM18-08BNS-ZW1 7900081
7900082
Inductive proximity sensors, IM 18 series, DC
8
8
8
PNP
NPN
PNP
300
300
300
Connector M12 x 1 mm
Connector M12 x 1 mm
Connector M12 x 1 mm
IM18-08BPS-ZC1
IM18-08BNS-ZC1
IM18-08BPO-ZC1
7900085
7900086
7900087
12
12 PNP
NPN 300
300 Cable 2 m
Cable 2 m IM18-12NPS-ZW1
IM18-12NNS-ZW1 7900093
7900094
12
12
12
PNP
NPN
PNP
300
300
300
Connector M12 x 1 mm
Connector M12 x 1 mm
Connector M12 x 1 mm
IM18-12NPS-ZC1
IM18-12NNS-ZC1
IM18-12NPO-ZC1
7900097
7900098
7900099
* see installation notes
*
*
*
*
*
SICK
46 8 007 755.0300
Inductive proximity sensors
IM 18 series, sensing range 5 / 8 mm
DC 4-wir e, metal housing
Features
For harsh environment,
resistant to most cutting oils
Enclosure rating IP 68
Can be installed flush or
non-flush in metal
PNP or NPN output
Complementary output
function
Short-circuit protection
(pulsed)
Robust brass housing,
nickel-plated with fine thread
M12 x 1 mm
Internal enclosure housing
in technopolymer
Connector
LED status indicator
(NO function)
Accessories
Round connectors
Mounting bracket
Connection diagram
2
1
4
3
Wire colour Contact Assignment
bn brown 1 + V DC
wh white 2 NC
bu blue 3 - V DC
bk black 4 NO
M18x1
M18x1
827
63
LED
M12x1
24
24
LED
M12x1
63
35
PNP NPN
1+1+
44 22
3
3
--
DC DC
Dimensions in mm
comple-
mentary comple-
mentary
For harsh environment
SICK 47
8 007 755.0300
Selection table
Sensing
range sn
mm
Installation
in metal Connection Order number
Switching
output TypeOutput
function Switching
frequency f
in Hz
5
5
PNP
NPN
complementary
1000
1000
IM18-05BPP-ZC1
IM18-05BNP-ZC1
7902931
7902932
8
8
PNP
NPN
complementary
complementary
complementary
1000
1000
IM18-08NPP-ZC1
IM18-08NNP-ZC1
7902933
7902934
Operating voltage Ub
Ripple Upp
Voltage drop Ud
(at Ia max.)
Power consumption
(without load)
Continuous current Ia
Time delay before
availability tv
Hysteresis H
Repeatability R
(Ub and Ta constant)
Temperature drift
EMC
10 ... 30 V DC
10%
0.8 V
20 mA
400 mA
100 ms
2% - 10% of sr
5% of sr
± 10% of sr
to EN 60 947-5-2
Short-circuit protection
(pulsed)
Reverse polarity protection
Power-up pulse suppression
Enclosure rating
Shock and vibration
stress
Ambient temperature Ta
Housing material
Tightening torque
yes
yes
yes
IP 68
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 70 °C
Brass, nickel-plated,
plastic
40 Nm
Electrical and mechanical data
Connector
M12 x 1 mm
Connector
M12 x 1 mm
Connector
M12 x 1 mm
Connector
M12 x 1 mm
Inductive proximity sensors, IM 18 series, DC
SICK
48 8 007 755.0300
Inductive proximity sensors
IM 18 series, sensing range 5 / 8 mm
DC 4-wir e, metal housing
Features
Free configurable output
functions in one sensor
PNP / NO, PNP / NC
NPN / NO, NPN / NC
Can be installed flush or
non-flush in metal
Short-circuit protection
Robust brass housing,
nickel-plated with fine thread
M18 x 1 mm
Cable or connector
Enclosure rating IP 67
LED status indicator
(NO function)
Accessories
Round connectors
Mounting bracket
Connection diagram
1
4
bn
bk
PNP
PNP
DC
-
-
DC
+1
4
bn
bk
NPN
NPN
DC
-
DC
+
2wh
3bu 3bu
2wh
++
-
3
4
bu
bk
3
4
bu
bk
2wh
1bn 1bn
2wh
Wire colour Contact configurable output function
bn brown 1 +V DC -V DC +V DC -V DC
wh white 2 +V DC +V DC NO NC
bu blue 3 - V DC +V DC -V DC +V DC
bk black 4 NO NC -V DC -V DC
NPN
PNP 2
1
4
3
Dimensions in mm
Multitalents
M18x1
37
860
24
M18x1
4560
24
M18x1
874
24
M18x1
74
24
M12x1
LED, 4X90°
LED, 4X90°
M12x1
37
45
LED
LED
SICK 49
8 007 755.0300
Selection table
Sensing
range sn
mm
Installation
in metal Connection Order number
PNP/NPN
config.
Switching
output TypeOutput
function Switching
frequency f
in Hz
3005 Cable 2 m IM18-05BCP-ZW1 7902935
PNP/NPN
config. 3005IM18-05BCP-ZC1 7902936
PNP/NPN
config. 3008 Cable 2 m IM18-08NCP-ZW1 7902937
PNP/NPN
config. 3008IM18-08NCP-ZC1 7902938
config.
config.
config.
config.
Operating voltage Ub
Ripple Upp
Voltage drop Ud
(at Ia max.)
Power consumption
(without load)
Continuous current Ia
Time delay before
availability tv
Hysteresis H
Repeatability R
(Ub and Ta constant)
Temperature drift
EMC
10 ... 30 V DC
10%
1.2 V
30 mA
100 mA
200 ms
2% - 10% of sr
5% of sr
± 10% of sr
to prEN 60 947-5-2
Short-circuit protection
Reverse polarity protection
Power-up pulse suppression
Enclosure rating to EN 60529
Shock and vibration
stress
Ambient temperature Ta
Housing material
Tightening torque
Connection cable
yes
yes
yes
IP 67
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 70 °C
Brass, nickel-plated,
plastic
40 Nm
PVC, 4 x 0.34 mm2
Electrical and mechanical data
Connector
M12 x 1 mm
Connector
M12 x 1 mm
Inductive proximity sensors, IM 18 series, DC
50 SICK 8 007 755.0300
Inductive proximity sensors
IM 30 series, sensing range 10 / 15 mm
DC 3-wire, metal housing
Wire colour Contact Assignment
bn brown 1 + V DC
bk black 2/4 NC/NO
bu blue 3 - V DC
2
1
4
3
Dimensions in mm
1
4
3
bn
bk
bu
1
2
3
bn
bk
bu
PNP
PNP +
DC
-
-
DC
+1
4
3
bn
bk
bu
1
2
3
bn
bk
bu
NPN
NPN +
DC
-
-
DC
+
Connection diagram
Standard series
M30x1.5
12 38
36
60
M30x1.5
36
5060
M30x1.5
12 38
M30x1.5
50
LED, 4x90°
LED, 4x90°
M12x1
M12x1
36
36
76 16
76 16
Features
Can be installed flush or
non-flush in metal
PNP or NPN output
Normally open/
normally closed function
High switching frequency
Short-circuit protection
(pulsed)
Robust brass housing,
nickel-plating with fine thread
M30 x 1.5 mm
Cable or connector
Enclosure rating IP 67
LED status indicator
Accessories
Round connectors
Mounting bracket
LED
LED
51
SICK8 007 755.0300
Electrical and mechanical data
Selection table
Operating voltage Ub
Ripple Upp
Voltage drop Ud
(at Ia max.)
Power consumption
(without load)
Continuous current Ia
Time delay before
availability tv
Hysteresis H
Repeatability R
(Ub and Ta constant)
Temperature drift
EMC
10 ... 30 V DC
10%
1 V
20 mA
400 mA
100 ms
2% - 10% of sr
2% of sr
± 10% of sr
to EN 60 947-5-2
Short-circuit protection
(pulsed)
Reverse polarity protection
Power-up pulse suppression
Enclosure rating to EN 60529
Shock and vibration
stress
Ambient temperature Ta
Housing material
Tightening torque
Connection cable
yes
yes
yes
IP 67
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 70 °C
Brass, nickel-plated,
plastic
60 Nm
PVC, 3 x 0.5 mm2
10
10
Sensing
range sn
mm
Installation
in metal Connection Order number
PNP
NPN
Switching
output TypeOutput
function Switching
frequency f
in Hz
200
200 Cable 2 m
Cable 2 m IM30-10BPS-ZW1
IM30-10BNS-ZW1 6020274
6020275
Inductive proximity sensors, IM 30 series, DC
10
10
10
PNP
NPN
PNP
200
200
200
Connector M12 x 1 mm
Connector M12 x 1 mm
Connector M12 x 1 mm
IM30-10BPS-ZC1
IM30-10BNS-ZC1
IM30-10BPO-ZC1
6020278
6020279
6020280
15
15
15
PNP
NPN
PNP
200
200
200
Cable 2 m
Cable 2 m
Cable 2 m
IM30-15NPS-ZW1
IM30-15NNS-ZW1
IM30-15NPO-ZW1
6020282
6020283
6020284
15
15 PNP
NPN 200
200
Connector M12 x 1 mm
Connector M12 x 1 mm
IM30-15NPS-ZC1
IM30-15NNS-ZC1 6020286
6020287
52 SICK 8 007 755.0300
Inductive proximity sensors
IM 30 series, sensing range 10 / 15 mm
DC 3-wire, metal housing
Wire colour Contact Assignment
bn brown 1 + V DC
bk black 4 NO
bu blue 3 - V DC
2
1
4
3
Features
Can be installed flush or
non-flush in metal
PNP or NPN output
Normally open function
Short-circuit protection
(pulsed)
Robust brass housing,
nickel-plating with fine thread
M30 x 1.5 mm
Cable or connector
Enclosure rating IP 67
LED status indicator
Accessories
Round connectors
Mounting bracket
Dimensions in mm
Connection diagram
Short version
15
25
22
40
50
50
37
40
M30x1.5M30x1.5M30x1.5M30x1.5
36
36
36
36
LED, 4x90°
LED, 4x90°
LED
M12x1
M12x1
LED
1
4
3
bn
bk
bu
PNP
-
DC
+
1
4
3
bn
bk
bu
NPN
-
DC
+
53
SICK8 007 755.0300
Electrical and mechanical data
Selection table
Operating voltage Ub
Ripple Upp
Voltage drop Ud
(at Ia max.)
Power consumption
(without load)
Continuous current Ia
Time delay before
availability tv
Hysteresis H
Repeatability R
(Ub and Ta constant)
Temperature drift
EMC
10 ... 30 V DC
10% of Ub
1.5 V
10 mA
300 mA
15 ms
1% - 10% of sr
3% of sr
± 10% of sr
to EN 60 947-5-2
Wire-break protection
Short-circuit protection
(pulsed)
Reverse polarity protection
Power-up pulse suppression
Enclosure rating to EN 60529
Shock and vibration
stress
Ambient temperature Ta
Housing material
Tightening torque
Connection cable
yes
yes
yes
yes
IP 67
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 75 °C
Brass, nickel-plated,
plastic
50 Nm
PUR-PVC, 3 x 0.5 mm2
Sensing
range sn
mm
Installation
in metal Connection Order number
Switching
output TypeOutput
function Switching
frequency f
in Hz
10
10
10
10
PNP
NPN
PNP
NPN
500
500
500
500
Cable 2 m
Cable 2 m
Connector M12 x 1 mm
Connector M12 x 1 mm
IM30-10BPS-ZUK
IM30-10BNS-ZUK
IM30-10BPS-ZCK
IM30-10BNS-ZCK
1017434
1017446
1017436
1017448
15
15
15
15
PNP
NPN
PNP
NPN
500
500
500
500
Cable 2 m
Cable 2 m
Connector M12 x 1 mm
Connector M12 x 1 mm
IM30-15NPS-ZUK
IM30-15NNS-ZUK
IM30-15NPS-ZCK
IM30-15NNS-ZCK
1017435
1017447
1017437
1017449
Inductive proximity sensors, IM 30 series, DC
54 SICK 8 007 755.0300
Inductive proximity sensors
IM 30 series, sensing range 15 / 20 mm
DC 3-wire, metal housing
Features
Enhanced sensing range
Can be installed flush or
non-flush in metal
PNP or NPN output
Normally open/
normally closed function
High switching frequency
Short-circuit protection
(pulsed)
Robust brass housing,
nickel-plated with fine thread
M30 x 1.5 mm
Cable or connector
Enclosure rating IP 67
LED status indicator
Accessories
Round connectors
Mounting bracket
Wire colour Contact Assignment
bn brown 1 + V DC
bk black 2/4 NC/NO
bu blue 3 - V DC
Connection diagram
1
4
3
bn
bk
bu
1
2
3
bn
bk
bu
PNP
PNP +
DC
-
-
DC
+1
4
3
bn
bk
bu
1
2
3
bn
bk
bu
NPN
NPN +
DC
-
-
DC
+
2
1
4
3
Dimensions in mm
Advanced series
M30x1,5
12 38
36
60
M30x1,5
36
5060
M30x1,5
12 38
M30x1,5
50
LED, 4x90°
LED, 4x90°
M12x1
M12x1
36
36
16
16
76
76
LED
LED
55
SICK8 007 755.0300
Electrical and mechanical data
Selection table
Operating voltage Ub
Ripple Upp
Voltage drop Ud
(at Ia max.)
Power consumption
(without load)
Continuous current Ia
Time delay before
availability tv
Hysteresis H
Repeatability R
(Ub and Ta constant)
Temperature drift
EMC
10 ... 30 V DC
10% of Ub
1 V
10 mA
400 mA
100 ms
2% - 15% of sr
5% of sr
± 10% of sr
to EN 60 947-5-2
Short-circuit protection
(pulsed)
Reverse polarity protection
Power-up pulse suppression
Enclosure rating to EN 60529
Shock and vibration
stress
Ambient temperature Ta
Housing material
Tightening torque
Connection cable
yes
yes
yes
IP 67
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 70 °C
Brass, nickel-plated,
plastic
60 Nm
PVC, 3 x 0.5 mm2
15
15
15
Sensing
range sn
mm
Installation
in metal Connection type Order number
PNP
NPN
PNP
Switching
output TypeOutput
function Switching
frequency f
in Hz
150
150
150
Cable 2 m
Cable 2 m
Cable 2 m
IM30-15BPS-ZW1
IM30-15BNS-ZW1
IM30-15BPO-ZW1
7900141
7900142
7900143
15
15
15
PNP
NPN
PNP
150
150
150
Connector M12 x 1 mm
Connector M12 x 1 mm
Connector M12 x 1 mm
IM30-15BPS-ZC1
IM30-15BNS-ZC1
IM30-15BPO-ZC1
7900145
7900146
7900147
20
20 PNP
PNP 150
150 Cable 2 m
Cable 2 m IM30-20NPS-ZW1
IM30-20NPO-ZW1 7900153
7900155
Inductive proximity sensors, IM 30 series, DC
20
20 PNP
NPN 150
150
Connector M12 x 1 mm
Connector M12 x 1 mm
IM30-20NPS-ZC1
IM30-20NNS-ZC1 7900157
7900158
*
*
*
*
*
*
* see installation notes
56 SICK 8 007 755.0300
Connection diagram
Inductive proximity sensors
IH 03 series, sensing range 0.6 mm
DC 3-wir e, miniature metal housing
Features
Can be installed flush
PNP or NPN output
Normally open function
High switching frequency
Short-circuit protection
(pulsed)
Solid stainless steel housing
Cable
Enclosure rating IP 67
LED status indicator
Dimensions in mm
bn
bk
bu
PNP
-
DC
+
Wire colour Assignment
bn brown + V DC
bk black NO
bu blue - V DC
bn
bk
bu
NPN
-
DC
+
22
16
Ø 3
Ø 2.6
LED
Miniature series
57
SICK8 007 755.0300
Electrical and mechanical data
Selection table
Operating voltage Ub
Ripple Upp
Voltage drop Ud
(at Ia max.)
Power consumption
(without load)
Continuous current Ia
Time delay before
availability tv
Hysteresis H
Repeatability R
(Ub and Ta constant)
Temperature drift
EMC
10 ... 30 V DC
20% of Ub
0.6 V max.
10 mA
100 mA
10 ms
10% of sr
2%
± 10% of sr
to EN 60 947-5-2
Short-circuit protection
(pulsed)
Reverse polarity protection
Power-up pulse suppression
Enclosure rating to EN 60529
Shock and vibration
stress
Ambient temperature Ta
Housing material
Connection cable
yes
yes
yes
IP 67
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 70 °C
Stainless steel, plastic
PUR, 3 x 0.055 mm2
Sensing
range sn
mm
Installation
in metal Connection Order number
Switching
output TypeOutput
function Switching
frequency f
in Hz
0.6
0.6 PNP
NPN 2000
2000 Cable 2 m
Cable 2 m IH03-0B6PS-VU1
IH03-0B6NS-VU1 6020141
6020142
Normaly closed function available on request
Inductive proximity sensors, IH 03 series, DC
58 SICK 8 007 755.0300
Connection diagram
Inductive proximity sensors
IH 04 series, sensing range 0.8 mm
DC 3-wir e, miniature metal housing
Features
Can be installed flush
PNP or NPN output
Normally open function
High switching frequency
Short-circuit protection
(pulsed)
Solid stainless steel housing
Cable or connector
Enclosure rating IP 67
LED status indicator
Accessories
Round connectors
Dimensions in mm
Wire colour Contact Assignment
bn brown 1 + V DC
bk black 4 NO
bu blue 3 - V DC
1
4
3
bn
bk
bu
-
DC
+
+
DC
-
1
4
3
bn
bk
bu
PNP
NPN
1
4
3
18 25
LED Ø 3.5
LED
M8x1
Ø 6.5
Ø 4
18
19 38
Miniature series
59
SICK8 007 755.0300
Electrical and mechanical data
Selection table
Operating voltage Ub
Ripple Upp
Voltage drop Ud
(at Ia max.)
Power consumption
(without load)
Continuous current Ia
Time delay before
availability tv
Hysteresis H
Repeatability R
(Ub and Ta constant)
Temperature drift
EMC
10 ... 30 V DC
20% of Ub
2.0 V max.
10 mA
200 mA
10 ms
10% of sr
1.5%
± 10% of sr
to EN 60 947-5-2
Short-circuit protection
(pulsed)
Reverse polarity protection
Power-up pulse suppression
Enclosure rating to DIN 40050
Shock and vibration
stress
Ambient temperature Ta
Housing material
Connection cable
yes
yes
yes
IP 67
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 70 °C
Stainless steel, plastic
PVC, 3 x 0.14 mm2
Sensing
range sn
mm
Installation
in metal Connection Order number
Switching
output TypeOutput
function Switching
frequency f
in Hz
0.8
0.8
0.8
0.8
PNP
NPN
PNP
NPN
5000
5000
5000
5000
Cable 2 m
Cable 2 m
Connector M8 x 1 mm
Connector M8 x 1 mm
IH04-0B8PS-VW1
IH04-0B8NS-VW1
IH04-0B8PS-VT1
IH04-0B8NS-VT1
6020113
6020149
6020114
6020152
Normaly closed function available on request
Inductive proximity sensors, IH 04 series, DC
60 SICK 8 007 755.0300
Connection diagram
Inductive proximity sensors
IH 06 series, sensing range 1,5 mm
DC 3-wir e, metal housing
Features
Can be installed flush
PNP or NPN output
Normally open function
High switching frequency
Short-circuit protection
(pulsed)
Solid stainless steel housing
Cable or connector
Enclosure rating IP 67
LED status indicator
Accessories
Round connectors
1
4
3
Wire colour Contact Assignment
bn brown 1 + V DC
bk black 4 NO/NC
bu blue 3 - V DC
1
4
3
bn
bk
bu
-
DC
+
+
DC
-
1
4
3
bn
bk
bu
PNP
NPN
Dimensions in mm
Ø6.5
Ø 6.5
LED
LED
Ø 3.5
M8x1
2029
16
Miniature series
61
SICK8 007 755.0300
Electrical and mechanical data
Selection table
Operating voltage Ub
Ripple Upp
Voltage drop Ud
(at Ia max.)
Power consumption
(without load)
Continuous current Ia
Time delay before
availability tv
Hysteresis H
Repeatability R
(Ub and Ta constant)
Temperature drift
EMC
10 ... 30 V DC
20% of Ub
2.0 V max.
10 mA
200 mA
10 ms
10% of sr
5%
± 10% of sr
to EN 60 947-5-2
Short-circuit protection
(pulsed)
Reverse polarity protection
Power-up pulse suppression
Enclosure rating to EN 60529
Shock and vibration
stress
Ambient temperature Ta
Housing material
Connection cable
yes
yes
yes
IP 67
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 70 °C
Stainless steel, plastic
PVC, 3 x 0.14 mm2
1.5
1.5
1.5
1.5
Sensing
range sn
mm
Installation
in metal Connection Order number
PNP
NPN
PNP
NPN
Switching
output TypeOutput
function Switching
frequency f
in Hz
5000
5000
5000
5000
Cable 2 m
Cable 2 m
Connector M8 x 1 mm
Connector M8 x 1 mm
IH06-1B5PS-VWK
IH06-1B5NS-VWK
IH06-1B5PS-VTK
IH06-1B5NS-VTK
6020165
6020166
6020169
6020170
Inductive proximity sensors, IH 06 series, DC
16
26
5
6.25
12.5
Accessories
20
8
6
Mounting clamp for H06 type
Plastic with 2 srews
Order No. 7901771
62 SICK 8 007 755.0300
Connection diagram
Inductive proximity sensors
IH 06 series, sensing range 2 / 4 mm
DC 3-wir e, metal housing
Features
Enhanced sensing range
Can be installed flush or
non-flush in metal
PNP or NPN output
Normaly closed or
normaly open function
High switching frequency
Short-circuit protection
(pulsed)
Solid stainless steel housing
Cable or connector
Enclosure rating IP 67
LED status indicator
Accessories
Round connectors
Dimensions in mm
Advanced series
LED, 4x90°
Ø 6.5
Ø 6.5
Ø 6.5
Ø 6.5
50
50
LED, 4x90°
4
M8x1
M8x1
45
40.2
45
40.2
49.5
9.5
LED
LED
Wire colour Contact Assignment
bn brown 1 + V DC
bk black 4 NO/NC
bu blue 3 - V DC
1
4
3
bn
bk
bu
1
4
3
bn
bk
bu
PNP
PNP +
DC
-
-
DC
+1
4
3
bn
bk
bu
NPN
-
DC
+
3
1
4
63
SICK8 007 755.0300
Electrical and mechanical data
Operating voltage Ub
Ripple Upp
Voltage drop Ud
(at Ia max.)
Power consumption
(without load)
Continuous current Ia
Time delay before
availability tv
Hysteresis H
Repeatability R
(Ub and Ta constant)
Temperature drift
EMC
10 ... 30 V DC
10% of Ub
1.2 V
20 mA
200 mA
100 ms
2% - 15% of sr
5% of sr
± 10% of sr
to EN 60 947-5-2
Short-circuit protection
(pulsed)
Reverse polarity protection
Power-up pulse suppression
Enclosure rating to EN 60529
Shock and vibration
stress
Ambient temperature Ta
Housing material
Connection cable
yes
yes
yes
IP 67
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 70 °C
Stainless steel, plastic
PVC, 3 x 0.14 mm2
Inductive proximity sensors, IH 06 series, DC
16
26
5
6.25
12.5
Accessories
20
8
6
Mounting clamp for H06 type
Plastic with 2 srews
Order No. 7901771
Selection table
2
2
2
2
2
Sensing
range sn
mm
Installation
in metal Connection Order number
PNP
NPN
PNP
NPN
PNP
Switching
output TypeOutput
function Switching
frequency f
in Hz
3000
3000
3000
3000
3000
Cable 2 m
Cable 2 m
Connector M8 x 1 mm
Connector M8 x 1 mm
Connector M8 x 1 mm
IH06-02BPS-VW1
IH06-02BNS-VW1
IH06-02BPS-VT1
IH06-02BNS-VT1
IH06-02BPO-VT1
7900177
7900178
7900179
7900180
1016857
*
*
*
*
*
* see installation notes
4
4
4
PNP
NPN
PNP
3000
3000
3000
Cable 2 m
Cable 2 m
Connector M8 x 1 mm
IH06-04NPS-VW1
IH06-04NNS-VW1
IH06-04NPS-VT1
7900181
7900182
7900183
64 SICK 8 007 755.0300
Connection diagram
Inductive proximity sensors
IQ 05 series, sensing range 0.8 mm
DC 3-wir e, miniature metal housing
Features
Can be installed flush
PNP or NPN output
Normally open function
High switching frequency
Short-circuit protection
(pulsed)
Robust brass housing,
nickel-plated
Cable
Enclosure rating IP 67
LED status indicator
Dimensions in mm
3
bn
bk
bu
PNP
-
DC
+
Wire colour Assignment
bn brown + V DC
bk black NO
bu blue - V DC
bn
bk
bu
NPN
-
DC
+
5
5
14
25
M1.6
Ø 2.6
1.5
5.5
65
SICK8 007 755.0300
Electrical and mechanical data
Selection table
Operating voltage Ub
Ripple Upp
Voltage drop Ud
(at Ia= 200 mA)
Power consumption
(without load)
Continuous current Ia
Time delay before
availability tv
Hysteresis H
Repeatability R
(Ub and Ta constant)
Temperature drift
EMC
10 ... 30 V DC
20% of Ub
2.0 V max.
10 mA
200 mA
10 ms
10% of sr
1.5% of sr
± 10% of sr
to EN 60 947-5-2
Short-circuit protection
(pulsed)
Reverse polarity protection
Power-up pulse suppression
Enclosure rating to EN 60529
Shock and vibration
stress
Ambient temperature Ta
Housing material
Connection cable
yes
yes
yes
IP 67
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 70 °C
Brass, nickel-plated,
plastic
PUR, 3 x 0.055 mm2
Sensing
range sn
mm
Installation
in metal Connection Order number
Switching
output TypeOutput
function Switching
frequency f
in Hz
0.8
0.8 PNP
NPN 5000
5000 Cable 2 m
Cable 2 m IQ05-0B8PS-ZU1
IQ05-0B8NS-ZU1 6020161
6020162
Inductive proximity sensors, IQ 05 series, DC
Normaly closed function available on request
66 SICK 8 007 755.0300
Connection diagram
Inductive proximity sensors
IQ 08 series, sensing range 2 / 4 mm
DC 3-wir e, plastic housing
Features
Can be installed flush or
non-flush in metal
PNP or NPN output
High switching frequency
Short-circuit protection
(pulsed)
Small plastic housing
Cable or connector
Enclosure rating IP 67
LED status indicator
For the series IQ08-04N
the added plastic screws shall
be used
Installation notes see page 17
Accessories
Round connectors
1
4
3
Wire colour Contact Assignment
bn brown 1 + V DC
bk black 4 NO
bu blue 3 - V DC
1
4
3
bn
bk
bu
-
DC
+
+
DC
-
1
4
3
bn
bk
bu
PNP
NPN
LED
8
40 LED
20
2.6
40
8
M8x1
M8x1
20
2.6
5
8.1
10
5LED, 4x90°
LED, 4x90°
8.1
10 49
M3
M3
Dimensions in mm
67
SICK8 007 755.0300
Electrical and mechanical data
Selection table
Operating voltage Ub
Ripple Upp
Voltage drop Ud
(at Ia max.)
Power consumption
(without load)
Continuous current Ia
Time delay before
availability tv
Hysteresis H
Repeatability R
(Ub and Ta constant)
Temperature drift
EMC
10 ... 30 V DC
10% of Ub
1.5 V
10 mA
300 mA
2 ms
1% - 10% of sr
1% of sr
± 10% of sr
to EN 60 947-5-2
Wire-break protection
Short-circuit protection
(pulsed)
Reverse polarity protection
Power-up pulse suppression
Enclosure rating to EN 60529
Shock and vibration
stress
Ambient temperature Ta
Housing material
Connection cable
yes
yes
yes
yes
IP 67
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 75 °C
Plastic
PVC, 3 x 0.25 mm2
2
2
2
2
Sensing
range sn
mm
Installation
in metal Connection Order number
PNP
NPN
PNP
NPN
Switching
output TypeOutput
function Switching
frequency f
in Hz
5000
5000
5000
5000
Cable 2 m
Cable 2 m
Connector M8 x 1 mm
Connector M8 x 1 mm
4
4PNP
PNP 5000
5000 Cable 2 m
Connector M8 x 1 mm
IQ08-02BPS-KW1
IQ08-02BNS-KW1
IQ08-02BPS-KT1
IQ08-02BNS-KT1
IQ08-04NPS-KW1
IQ08-04NPS-KT1
7900195
7900196
7900197
7900198
7900199
7900201
Inductive proximity sensors, IQ 08 series, DC
68 SICK 8 007 755.0300
Connection diagram
Inductive proximity sensors
IQ 10 series, sensing range 3 / 6 mm
DC 3-wir e, plastic housing
Features
Can be installed flush or
non-flush in metal
PNP or NPN output
Normaly closed or
normaly open function
High switching frequency
Short-circuit protection
(pulsed)
Plastic housing
Cable or connector
Enclosure rating IP 67
LED status indicator
Installation notes see page 17
Accessories
Round connectors
Dimensions in mm
10.3
5.7 LED
28
Ø3.2
LED
22.2
3.4
3.2
2.9 16
10.3
2.9
10.3
5.7
M8x1
LED, 4x90°
28 37
M8x1
LED, 4x90°
Ø3.2
3.4
2.9
3.2
10.3
16
22.2 2.9
1
4
3
1
4
3
bn
bk
bu
1
4
3
bn
bk
bu
PNP
PNP +
DC
-
-
DC
+1
4
3
bn
bk
bu
NPN
-
DC
+
Wire colour Contact Assignment
bn brown 1 + V DC
bk black 4 NO
bu blue 3 - V DC
69
SICK8 007 755.0300
Electrical and mechanical data
Selection table
Operating voltage Ub
Ripple Upp
Voltage drop Ud
(at Ia max.)
Power consumption
(without load)
Continuous current Ia
Time delay before
availability tv
Hysteresis H
Repeatability R
(Ub and Ta constant)
Temperature drift
EMC
10 ... 30 V DC
10% of Ub
1.5 V
5 mA
300 mA
10 ms
1% - 15% of sr
1% of sr
± 10% of sr
to EN 60 947-5-2
Wire-break protection
Short-circuit protection
(pulsed)
Reverse polarity protection
Power-up pulse suppression
Enclosure rating to EN 60529
Shock and vibration
stress
Ambient temperature Ta
Housing material
Connection cable
yes
yes
yes
yes
IP 67
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 75 °C
Plastic
PVC, 3 x 0.25 mm2
3
3
3
3
3
Sensing
range sn
mm
Installation
in metal Connection Order number
PNP
NPN
PNP
NPN
PNP
Switching
output TypeOutput
function Switching
frequency f
in Hz
3000
3000
3000
3000
3000
Cable 2 m
Cable 2 m
Connector M8 x 1 mm
Connector M8 x 1 mm
Connector M8 x 1 mm
IQ10-03BPS-KW1
IQ10-03BNS-KW1
IQ10-03BPS-KT1
IQ10-03BNS-KT1
IQ10-03BPO-KT1
7900203
7900204
7900205
7900206
7901530
6
6
6
6
PNP
NPN
PNP
NPN
1000
1000
1000
1000
Cable 2 m
Cable 2 m
Connector M8 x 1 mm
Connector M8 x 1 mm
IQ10-06NPS-KW1
IQ10-06NNS-KW1
IQ10-06NPS-KT1
IQ10-06NNS-KT1
7900207
7900208
7900209
7900210
Inductive proximity sensors, IQ 10 series, DC
70 SICK 8 007 755.0300
Connection diagram
Inductive proximity sensors
IQ 12 series, sensing range 3 / 6 mm
DC 3-wir e, plastic housing
Features
Can be installed flush or
non-flush in metal
PNP or NPN output
High switching frequency
Short-circuit protection
(pulsed)
Plastic housing
Cable or connector
Enclosure rating IP 67
LED status indicator
Installation notes see page 17
Accessories
Round connectors
1
4
3
Wire colour Contact Assignment
bn brown 1 + V DC
bk black 4 NO
bu blue 3 - V DC
1
4
3
bn
bk
bu
-
DC
+
+
DC
-
1
4
3
bn
bk
bu
PNP
NPN
Dimensions in mm
26 5.5 12
6
40
3.2
3.2
17.8
432
4
4
10 16
M3
LED
LED
26 5.5 12
6
40
3.2
432 4
LED
LED
17.8
3.2
M8X1
M8X1
M8X1
M3
10 16
4
71
SICK8 007 755.0300
Electrical and mechanical data
Selection table
Operating voltage Ub
Ripple Upp
Voltage drop Ud
(at Ia max.)
Power consumption
(without load)
Continuous current Ia
Time delay before
availability tv
Hysteresis H
Repeatability R
(Ub and Ta constant)
Temperature drift
EMC
6 ... 36 V DC
10% of Ub
1.5 V
5 mA
300 mA
10 ms
1% - 15% of sr
1% of sr
± 10% of sr
to EN 60 947-5-2
Wire-break protection
Short-circuit protection
(pulsed)
Reverse polarity protection
Power-up pulse suppression
Enclosure rating to EN 60529
Shock and vibration
stress
Ambient temperature Ta
Housing material
Connection cable
yes
yes
yes
yes
IP 67
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 75 °C
Plastic
PVC, 3 x 0.25 mm2
3
3
3
3
Sensing
range sn
mm
Installation
in metal Connection Order number
PNP
NPN
PNP
NPN
Switching
output TypeOutput
function Switching
frequency f
in Hz
3000
3000
3000
3000
Cable 2 m
Cable 2 m
Connector M8 x 1 mm
Connector M8 x 1 mm
6
6PNP
PNP 1000
1000 Cable 2 m
Connector M8 x 1 mm
IQ12-03BPS-KW1
IQ12-03BNS-KW1
IQ12-03BPS-KT1
IQ12-03BNS-KT1
IQ12-06NPS-KW1
IQ12-06NPS-KT1
1016275
1016299
1016276
1016461
1016463
1016467
Inductive proximity sensors, IQ 12 series, DC
72 SICK 8 007 755.0300
Connection diagram
Inductive proximity sensors
IQ 40 series, sensing range 15 / 20 mm
DC 3-wire, plastic housing
Features
Can be installed flush or
non-flush in metal
Variable switching zone
PNP output
Programmable NO/NC
function
Short-circuit protection
(pulsed)
Plastic housing
Terminal
Enclosure rating IP 65
LED status indicator
Installation notes see page 17
Dimensions in mm
Terminal Assignment
1/3 + V DC
X NO/NC
2/4 - V DC
1/3
2/4
-
DC
+
progr.
X
Programming with wirelinks
Link closed: NO
Link open: NC
PNP
41 PG 13,5
27
PG 13,5
LED
121
101
10,4
45,6
61,5
32
41
30
5,1
77
41
73
SICK8 007 755.0300
Electrical and mechanical data
Selection table
Operating voltage Ub
Voltage drop Ud
(at Ia max. and Ub 24 V)
Power consumption
(without load)
Continuous current Ia
Time delay before
availability tv
Hysteresis H
Repeatability R
(Ub and Ta constant)
Temperature drift
EMC
10 ... 36 V DC
2.5 V
15 mA
250 mA
approx. 4 ms
1% - 15% of sr
10% of sr
± 10% of sr
to EN 60 947-5-2
Short-circuit protection
(pulsed)
Reverse polarity protection
Power-up pulse suppression
Enclosure rating to EN 60529
Protection class
Shock and vibration
stress
Ambient temperature Ta
Housing material
yes
yes
yes
IP 65
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 80 °C
Plastic
Sensing
range sn
mm
Installation
in metal Connection Order number
Switching
output TypeOutput
function Switching
frequency f
in Hz
progr. IQ40-15BPP-KK0
IQ40-20NPP-KK0
7900219
7900221
300
300
PNP
PNP
15
20 progr.
Terminal up to
2.5 mm2
Terminal up to
2.5 mm2
Inductive proximity sensors, IQ 40 series, DC
74 SICK 8 007 755.0300
Connection diagram
Inductive proximity sensors
IQ 40 series, sensing range 15 / 20 / 35 mm
DC 3/4-wir e, plastic housing
Features
Can be installed flush or
non-flush in metal
Variable switching zone
PNP output
NO and complementary
output function
Short-circuit protection
(pulsed)
Plastic housing
Connector
Enclosure rating IP 67
LED status indicator
LED function indicator
Installation notes see page 17
(only normaly open function)
Accessories
Round connectors
Dimensions in mm
Short version
40 40
M12x1
30
40
LED
17
46
61
20
Contact Assignment
1 + V DC
4NO
3 - V DC
2 free
Contact Assignment
1 + V DC
2NC
3 - V DC
4NO
PNP 1+
4
2
3
-
DC
+
DC
-
1
4
3
4
3
PNP
1
3
4
2
66.5
comple-
mentary
75
SICK8 007 755.0300
Electrical and mechanical data
Selection table
Operating voltage Ub
Voltage drop Ud
(at Ia max. and Ub 24 V)
Power consumption
(without load)
Continuous current Ia
Time delay before
availability tv
Hysteresis H
Repeatability R
(Ub and Ta constant)
Temperature drift
EMC
10 ... 36 V DC
2.5 V
15 mA
250 mA
approx. 4 ms
1% - 15% of sr
10% of sr
± 10% of sr
to EN 60 947-5-2
Short-circuit protection
(pulsed)
Reverse polarity protection
Power-up pulse suppression
Enclosure rating to EN 60529
Protection class
Shock and vibration
stress
Ambient temperature Ta
Housing material
yes
yes
yes
IP 67
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 70 °C
Plastic
Sensing
range sn
mm
Installation
in metal Connection Order number
Switching
output TypeOutput
function Switching
frequency f
in Hz
15
20
Connector M12 x 1 mm
Connector M12 x 1 mm
35
35
PNP
PNP
PNP
PNP
antivalent
antivalent
100
100
300
200
Connector M12 x 1 mm
Connector M12 x 1 mm
IQ40-35NPS-KC0
IQ40-35NPP-KCK
IQ40-15BPS-KC0
IQ40-20BPP-KCK
7900223
6012014
7900224
6012015
Inductive proximity sensors, IQ 40 series, DC
76 SICK 8 007 755.0300
Connection diagram
Inductive proximity sensors
IQ 80 series, sensing range 60 mm
DC 3-wire, plastic housing
Features
Can be installed non-flush
in metal
Adjustable switching distance
between 20 to 60 mm
PNP output
Programmable NO/NC
function
Short-circuit protection
(pulsed)
Robust plastic housing
Terminal connection
Enclosure rating IP 65
LED status indicator
LED
40 12
27
18
POTI
80
65
40
9.3
5.5
105
2
1+
-
DC
+
DC
Terminal Assignment
1 + V DC
2 Output
3 free
4 - V DC / NO
5 - V DC / NC
PG 13.5
7.5
65 16
3
4
5
progr.
-
NO NC
PNP
Dimensions in mm
77
SICK8 007 755.0300
Electrical and mechanical data
Selection table
Operating voltage Ub
Voltage drop Ud
Power consumption
(without load)
Continuous current Ia
Time delay before
availability tv
Hysteresis H
Repeatability R
(Ub and Ta constant)
Temperature drift
EMC
10 ... 36 V DC
2.5 V
at Ia max. and Ub 24 V
15 mA
250 mA
approx. 250 ms
1% - 15% of sr
10% of sr
± 10% of sr
to EN 60 947-5-2
Short-circuit protection
(pulsed)
Reverse polarity protection
Power-up pulse suppression
Enclosure rating to EN 60529
Protection class
Shock and vibration
stress
Ambient temperature Ta
Housing material
yes
yes
yes
IP 65
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 80 °C
Plastic
Sensing
range sn
mm
Installation
in metal Connection Order number
Switching
output TypeOutput
function Switching
frequency f
in Hz
progr. Terminal up to
2.5 mm2
PNP60 4 IQ80-60NPP-KK0 7900227
Inductive proximity sensors, IQ 80 series, DC
78 SICK 8 007 755.0300
Inductive proximity sensors
IM 12 series, sensing range 2 / 4 mm
DC 2-wir e, metal housing
Features
Can be installed flush or
non-flush in metal
Normaly open function
Short-circuit protection
(pulsed)
Robust brass housing,
nickel-plated with fine thread
M12 x 1 mm
Cable or connector
Enclosure rating IP 67
LED-status indicator
Accessories
Round connector
Mounting bracket Connection diagram
DC
2
31
4
Wire colour Contact Assignment
bn brown 1 + V DC
bu blue 2/4
-
V DC
M12x1
545
60
M12x1
17
50
M12x1
17
LED, 4x90°
60
48 75
5
17
75
53
M12x1
LED, 4x90°
M12x1
M12x1
1bn
4bu
+
-
DC
1bn
2bu +
-
17 LED
LED
Dimensions in mm
79
SICK8 007 755.0300
10 ... 30 V DC
10%
2.8 V
3 mA
100 mA
0.8 mA
50 ms
2% - 10% of sr
5% of sr
± 10% of sr
to EN 60 947-5-2
Electrical and mechanical data
2
2IM12-02BDS-ZW1
IM12-02BDS-ZC1 6020310
6020312
Selection table
Sensing
range sn
mm
Installation
in metall Order numberOutput
function
1500
1500
Switching
frequency f
in Hz
Connection
Cable 2 m
Connector
M12 x 1 mm
Type
Operating voltage Ub
Ripple Upp
Voltage drop Ud
(at Ia max)
Load current
Continuous current Ia
Off state current
Time delay before
availability tv
Hysteresis H
Repeatability R
(Ub and Ta constant)
Temperature drift
EMC
Short-circuit protection
(pulsed)
Reverse polarity protection
Enclosure rating to EN 60529
Shock and vibration
stress
Ambient temperature Ta
Housing material
Tightening torque
Connection cable
yes
yes
IP 67
30 g, 11 ms
10 bis 55 Hz, 1 mm
- 25 ... + 70 °C
Brass, nickel-plated,
plastic
10 Nm
PVC, 2 x 0.22 mm2
Normaly closed function available on request
4
4Cable 2 m
Connector
M12 x 1 mm
IM12-04NDS-ZW1
IM12-04NDS-ZC1 6020314
6020316
1500
1500
Inductive proximity sensors, IM 12 series, DC
80 SICK 8 007 755.0300
Inductive proximity sensors
IM 18 series, sensing range 5 / 8 mm
DC 2-wir e, metal housing
Features
Can be installed flush or
non-flush in metal
Normaly open function
Short-circuit protection
(pulsed)
Robust brass housing,
nickel-plated with fine thread
M18 x 1 mm
Cable or connector
Enclosure rating IP 67
LED-status indicator
Accessories
Round connector
Mounting bracket Connection diagram
DC
2
31
4
Wire colour Contact Assignment
bn brown 1 + V DC
bu blue 2/4
-
V DC
1bn
4bu
+
-
DC
1bn
2bu +
-
M18x1
M18x1
M18x1
M18x1
850
24
8
24
64
24
4050
64
32
24
LED, 4x90°
M12x1
40
M12x1
LED, 4x90°
48
LED
LED
Dimensions in mm
81
SICK8 007 755.0300
Electrical and mechanical data
5
5IM18-05BDS-ZW1
IM18-05BDS-ZC1 6020318
6020320
Selection table
300
300 Cable 2 m
Connector
M12 x 1 mm
Sensing
range sn
mm
Installation
in metall Order numberOutput
function Switching
frequency f
in Hz
Connection Type
10 ... 30 V DC
10%
2.8 V
3 mA
100 mA
0.8 mA
50 ms
2% - 10% of sr
2% of sr
± 10% of sr
to EN 60 947-5-2
Operating voltage Ub
Ripple Upp
Voltage drop Ud
(at Ia max)
Load current
Continuous current Ia
Off state current
Time delay before
availability tv
Hysteresis H
Repeatability R
(Ub and Ta constant)
Temperature drift
EMC
Short-circuit protection
(pulsed)
Reverse polarity protection
Enclosure rating to EN 60529
Shock and vibration
stress
Ambient temperature Ta
Housing material
Tightening torque
Connection cable
yes
yes
IP 67
30 g, 11 ms
10 bis 55 Hz, 1 mm
- 25 ... + 70 °C
Brass nickel-plated,
plastic
30 Nm
PVC, 2 x 0.34 mm2
8
8Cable 2 m
Connector
M12 x 1 mm
IM18-08NDS-ZW1
IM18-08NDS-ZC1 6020322
6020324
300
300
Inductive proximity sensors, IM 18 series, DC
Normaly closed function available on request
82 SICK 8 007 755.0300
Inductive proximity sensors
IM 30 series, sensing range 10 / 15 mm
DC 2-wir e, metal housing
Connection diagram
DC
2
31
4
Wire colour Contact Assignment
bn brown 1 + V DC
bu blue 2/4
-
V DC
1bn
4bu
+
-
DC
1bn
2bu +
-
M30x1.5
12 38
36
60
M30x1.5
36
5060
M30x1.5
12 38
M30x1.5
50
LED, 4x90°
LED, 4x90°
M12x1
M12x1
36
36
76 16
76 16
LED
LED
Dimensions in mm
Features
Can be installed flush or
non-flush in metal
Normaly open function
Short-circuit protection
(pulsed)
Robust brass housing,
nickel-plated with fine thread
M30 x 1 mm
Cable or connector
Enclosure rating IP 67
LED-status indicator
Accessories
Round connector
Mounting bracket
83
SICK8 007 755.0300
yes
yes
IP 67
30 g, 11 ms
10 bis 55 Hz, 1 mm
- 25 ... + 70 °C
Brass, nickel-plated,
plastic
60 Nm
PVC, 2 x 0.34 mm2
10 ... 30 V DC
10%
2.8 V
3 mA
100 mA
0.8 mA
50 ms
2% - 10% of sr
2% of sr
± 10% of sr
to EN 60 947-5-2
Electrical and mechanical data
10
10 IM30-10BDS-ZW1
IM30-10BDS-ZC1 6020326
6020328
Selection table
150
150 Cable 2 m
Connector
M12 x 1 mm
Operating voltage Ub
Ripple Upp
Voltage drop Ud
(at Ia max)
Load current
Continuous current Ia
Off state current
Time delay before
availability tv
Hysteresis H
Repeatability R
(Ub and Ta constant)
Temperature drift
EMC
Short-circuit protection
(pulsed)
Reverse polarity protection
Enclosure rating to EN 60529
Shock and vibration
stress
Ambient temperature Ta
Housing material
Tightening torque
Connection cable
Sensing
range sn
mm
Installation
in metall Order numberOutput
function Switching
frequency f
in Hz
Connection Type
15
15 Cable 2 m
Connector
M12 x 1 mm
IM30-15NDS-ZW1
IM30-15NDS-ZC1 6020330
6020332
150
150
Inductive proximity sensors, IM 30 series, DC
Normaly closed function available on request
84 SICK 8 007 755.0300
Inductive proximity sensors
IM 12 series, sensing range 2 / 4 mm
AC 2-wir e, metal housing
Features
Can be installed flush or
non-flush in metal
Broad operating voltage range
in AC
Normally open/
normally closed function
Robust brass housing,
nickel-plated, with fine thread
M12 x 1 mm
Enclosure rating IP 67
LED status indicator
Accessories
Mounting bracket
Wire colour Assignment
bn brown L1
bu blue N
Connection diagram
M12x1
AC
L1
N
AC
L1
N
bn
bu
bn
bu
17
46
71
4
18
Ø 9
17
LED
LED
Ø 9
50
71 18
M12x1
Dimensions in mm
85
SICK8 007 755.0300
Electrical and mechanical data
20 ... 250 V AC
8.5 V AC
250 mA AC (... + 50 °C)
200 mA AC (... + 80 °C)
0.9 A (20 ms/0.5 Hz)
8 mA
3 mA (250 V AC)
1.5 mA (120 V AC)
approx. 10 ms
1% - 15% of sr
10% of sr
± 10% of sr
to EN 60 947-5-2
Wire-break protection
Short-circuit protection
(pulsed)
Reverse polarity protection
Power-up pulse suppression
Enclosure rating to EN 60529
Protection class
Shock and vibration
stress
Ambient temperature Ta
Housing material
Tightening torque
Connection cable
-
-
-
yes
IP 67
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 80 °C
Brass, nickel-plated, plastic
7 Nm
PUR-PVC, 2 x 0.5 mm2
2
2
4
4
Sensing
range sn
mm
Installation
in metal Connection Order number
TypeSwitching frequency f
in Hz
25
25
25
25
Cable 2 m
Cable 2 m
Cable 2 m
Cable 2 m
IM12-02BAS-ZU0
IM12-02BAO-ZU0
IM12-04NAS-ZU0
IM12-04NAO-ZU0
7902118
7902119
7902120
7902121
Operating voltage Ub
Voltage drop Ud
(at Ia max.)
Continuous current Ia
Peak current IK
Min. load current
Residual current
Time delay before
availability tv
Hysteresis H
Repeatability R
(Ub and Ta constant)
Temperature drift
EMC
Output
function
Selection table
Inductive proximity sensors, IM 12 series, AC
86 SICK 8 007 755.0300
Inductive proximity sensors
IM 18 series, sensing range 5 / 8 mm
AC / DC 2-wir e, metal housing
Features
Can be installed flush or
non-flush in metal
Broad operating voltage range
in AC and DC
Normally open/
normally closed function
High switching frequency
Robust brass housing,
nickel-plated, with fine thread
M18 x 1 mm
Enclosure rating IP 67
LED status indicator
Accessories
Mounting bracket
Wire colour Assignment
bn brown L1 / +
bu blue N / -
Connection diagram
24
50
80 18
Ø 9
Ø 9
24
58
80 18
M18x1
L1 / +
N/-
AC/DC
L1 / +
N/-
bn
bu
bn
bu
LED
LED
M18x1
8
AC/DC
Dimensions in mm
87
SICK8 007 755.0300
Electrical and mechanical data
20 ... 250 V AC / DC
6.5 V AC / 6 V DC
350 mA AC (... + 50 °C)
250 mA AC (... + 80 °C)
100 mA DC
2.2 A (20ms/0.5 Hz)
5 mA
2.5 mA (250 V AC)
1.3 mA (110 V AC)
0.8 mA (24 V DC)
approx. 8 ms
1% - 15% of sr
10% of sr
± 10% of sr
to EN 60 947-5-2
Wire-break protection
Short-circuit protection
(pulsed)
Reverse polarity protection
Power-up pulse suppression
Enclosure rating to EN 60529
Protection class
Shock and vibration
stress
Ambient temperature Ta
Housing material
Tightening torque
Connection cable
-
-
-
yes
IP 67
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 80 °C
Brass, nickel-plated, plastic
35 Nm
PUR-PVC, 2 x 0.5 mm2
5
5
8
8
Sensing
range sn
mm
Installation
in metal Connection Order number
TypeSwitching frequency f
in Hz
25 (AC) / 100 (DC)
25 (AC) / 100 (DC)
25 (AC) / 100 (DC)
25 (AC) / 100 (DC)
Cable 2 m
Cable 2 m
Cable 2 m
Cable 2 m
IM18-05BUS-ZU0
IM18-05BUO-ZU0
IM18-08NUS-ZU0
IM18-08NUO-ZU0
7902122
7902123
7902124
7902125
Operating voltage Ub
Voltage drop Ud
(at Ia max.)
Continuous current Ia
Peak current IK
Min. load current
Residual current
Time delay before
availability tv
Hysteresis H
Repeatability R
(Ub and Ta constant)
Temperature drift
EMC
Output
function
Selection table
Inductive proximity sensors, IM 18 series, AC / DC
88 SICK 8 007 755.0300
Inductive proximity sensors
IM 30 series, sensing range 10 / 15 mm
AC / DC 2-wir e, metal housing
Features
Can be installed flush or
non-flush in metal
Broad operating voltage range
in AC and DC
Normally open/
normally closed function
Robust brass housing,
nickel-plated, with fine thread
M30 x 1.5 mm
Enclosure rating IP 67
LED status indicator
Accessories
Mounting bracket
Wire colour Assignment
bn brown L1 / +
bu blue N / -
Connection diagram
81
AC/DC
L1 / +
N/-
AC/DC
L1 / +
N/-
bn
bu
bn
bu
15 44
36
LED
Ø 9
81
59
36
LED
Ø 9
18
18
M30x1.5
M30x1.5
Dimensions in mm
89
SICK8 007 755.0300
Electrical and mechanical data
20 ... 250 V AC / DC
6.5 V AC / 6 V DC
350 mA AC (... + 50 °C)
250 mA AC (... + 80 °C)
100 mA DC
2.2 A (20ms/0.5 Hz)
5 mA
2.5 mA (250 V AC)
1.3 mA (110 V AC)
0.8 mA (24 V DC)
approx. 8 ms
1% - 15% of sr
10% of sr
± 10% of sr
to EN 60 947-5-2
Wire-break protection
Short-circuit protection
(pulsed)
Reverse polarity protection
Power-up pulse suppression
Enclosure rating to EN 60529
Protection class
Shock and vibration
stress
Ambient temperature Ta
Housing material
Tightening torque
Connection cable
-
-
-
yes
IP 67
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 80 °C
Brass, nickel-plated, plastic
50 Nm
PUR-PVC, 2 x 0.5 mm2
10
10
15
15
Sensing
range sn
mm
Installation
in metal Connection Order number
TypeSwitching frequency f
in Hz
25 (AC) / 30 (DC)
25 (AC) / 30 (DC)
25 (AC) / 30 (DC)
25 (AC) / 30 (DC)
Cable 2 m
Cable 2 m
Cable 2 m
Cable 2 m
IM30-10BUS-ZU0
IM30-10BUO-ZU0
IM30-15NUS-ZU0
IM30-15NUO-ZU0
7902126
7902127
7902128
7902129
Operating voltage Ub
Voltage drop Ud
(at Ia max.)
Continuous current Ia
Peak current IK
Min. load current
Residual current
Time delay before
availability tv
Hysteresis H
Repeatability R
(Ub and Ta constant)
Temperature drift
EMC
Output
function
Selection table
Inductive proximity sensors, IM 30 series, AC / DC
90 SICK 8 007 755.0300
Inductive proximity sensors
IH 20 series, sensing range 10 mm
AC / DC 2-wir e, plastic housing
Wire colour Assignment
bn brown L1 / +
bu blue N / -
Connection diagram
AC/DC
L1 / +
N/-
AC/DC
L1 / +
bn
bu
bn
55 77
Ø 20
LED
Ø 9
18
N / -
bu
Dimensions in mm
Features
Can be installed non-flush
in metal
Broad operating voltage range
in AC and DC
Normally open function
Plastic housing
Enclosure rating IP 67
LED status indicator
Accessories
Mounting clamps incl.
91
SICK8 007 755.0300
Electrical and mechanical data
20 ... 250 V AC / DC
6.5 V AC / 6 V DC
350 mA AC (... + 50 °C)
250 mA AC (... + 80 °C)
100 mA DC
2.2 A (20ms/0.5 Hz)
5 mA
2.5 mA (250 V AC)
1.3 mA (110 V AC)
0.8 mA (24 V DC)
approx. 45 ms
1% - 15% of sr
10% of sr
± 10% of sr
to EN 60 947-5-2
Wire-break protection
Short-circuit protection
(pulsed)
Reverse polarity protection
Power-up pulse suppression
Enclosure rating to EN 60529
Protection class
Shock and vibration
stress
Ambient temperature Ta
Housing material
Connection cable
-
-
-
yes
IP 67
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 80 °C
Plastic
PUR-PVC, 2 x 0.5 mm2
10
Sensing
range sn
mm
Installation
in metal Connection Order number
TypeSwitching frequency f
in Hz
25 (AC) / 70 (DC) Cable 2 m IH20-10NUS-KU0 7902130
Operating voltage Ub
Voltage drop Ud
(at Ia max.)
Continuous current Ia
Peak current IK
Min. load current
Residual current
Time delay before
availability tv
Hysteresis H
Repeatability R
(Ub and Ta constant)
Temperature drift
EMC
Output
function
Selection table
Inductive proximity sensors, IH 20 series, AC / DC
92 SICK 8 007 755.0300
Inductive proximity sensors
IH 34 series, sensing range 30 mm
AC / DC 2-wir e, plastic housing
Features
Can be installed non-flush
in metal
Enhanced sensing range
Broad operating voltage range
in AC and DC
Normally open/
normally closed function
Plastic housing
Enclosure rating IP 67
LED status indicator
Accessories
Mounting clamps incl.
Wire colour Assignment
bn brown L1 / +
bu blue N / -
Connection diagram
AC/DC
L1 / +
N/-
AC/DC
L1 / +
bn
bu
bn
Ø 34
LED
Ø 9
18
60 82
N/-
bu
Dimensions in mm
93
SICK8 007 755.0300
Electrical and mechanical data
20 ... 250 V AC / DC
6.5 V AC / 6 V DC
350 mA AC (... + 50 °C)
250 mA AC (... + 80 °C)
100 mA DC
2.2 A (20ms / 0.5 Hz)
5 mA
2.5 mA (250 V AC)
1.3 mA (110 V AC)
0.8 mA (24 V DC)
approx. 8 / 50 ms
1% - 15% of sr
10% of sr
± 10% of sr
to EN 60 947-5-2
Wire-break protection
Short-circuit protection
(pulsed)
Reverse polarity protection
Power-up pulse suppression
Enclosure rating to EN 60529
Protection class
Shock and vibration
stress
Ambient temperature Ta
Housing material
Connection cable
-
-
-
yes
IP 67
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 80 °C
Plastic
PUR-PVC, 2 x 0.5 mm2
Operating voltage Ub
Voltage drop Ud
(at Ia max.)
Continuous current Ia
Peak current IK
Min. load current
Residual current
Time delay before
availability tv
(with sn 20 / 30 mm)
Hysteresis H
Repeatability R
(Ub and Ta constant)
Temperature drift
EMC
30
30
Sensing
range sn
mm
Installation
in metal Connection Order numberTypeSwitching frequency f
in Hz
7
7Cable 2 m
Cable 2 m IH34-30NUS-KU0
IH34-30NUO-KU0 7902134
7902135
Output
function
Selection table
Inductive proximity sensors, IH 34 series, AC / DC
94 SICK 8 007 755.0300
Inductive proximity sensors
IQ 40 series, sensing range 15 / 20 mm
AC / DC 2-wir e, plastic housing
Features
Can be installed flush or
non-flush in metal
Variable switching zone
Broad operating voltage range
in AC and DC
Programmable switching
output: NO or NC
Plastic housing
Enclosure rating IP 65
Terminal connection
LED status indicator
Terminal Assignment
1/3 L1 / +
2/4 N / -
Connection diagram
27
PG 13.5 101
121
41
30
5.1
PG 13.5
41
32
LED
10.4 77
45.6
61.5
progr.
1/3
2/4
L1 / +
N/-
AC/DC
Programming with wire links
Link closed: NO
Link open: NC
41
Dimensions in mm
95
SICK8 007 755.0300
Electrical and mechanical data
20 ... 250 V AC / DC
6.5 V AC / 6 V DC
350 mA AC (... + 50 °C)
250 mA AC (... + 80 °C)
100 mA DC
2.2 A (20 ms / 0.5 Hz)
5 mA
2.5 mA (250 V AC)
1.3 mA (110 V AC)
0.8 mA (24 V DC)
approx. 8 ms
1% - 15% of sr
10% of sr
± 10% of sr
to EN 60 947-5-2
Wire-break protection
Short-circuit protection
(pulsed)
Reverse polarity protection
Power-up pulse suppression
Enclosure rating to EN 60529
Protection class
Shock and vibration
stress
Ambient temperature Ta
Housing material
-
-
-
yes
IP 65
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 80 °C
Plastic
Operating voltage Ub
Voltage drop Ud
(at Ia max.)
Continuous current Ia
Peak current IK
Min. load current
Residual current
Time delay before
availability tv
Hysteresis H
Repeatability R
(Ub and Ta constant)
Temperature drift
EMC
Selection table
Sensing
range sn
mm
Installation
in metal Connection Order numberTypeSwitching frequency f
in Hz
IQ40-15BUP-KK0
IQ40-20NUP-KK0
7902136
7902137
20 (AC) / 55 (DC)
20 (AC) / 55 (DC)
15
20
Terminal up to
2.5 mm2
Terminal up to
2.5 mm2
Output
function
progr.
progr.
Inductive proximity sensors, IQ 40 series, AC / DC
96 SICK 8 007 755.0300
Inductive proximity sensors
IQ 80 series, sensing range 60 mm
AC / DC 2-wir e, plastic housing
Features
Can be installed non-flush
in metal
Adjustable switching distance
between 20 and 60 mm
Broad operating voltage range
in AC and DC
Programmable switching
output: NO or NC
Robust plastic housing
Enclosure rating IP 65
Terminal connection
LED status indicator
Connection diagram
LED
40 12
27
18
POTI
16
80
65
7.5
65
PG 13.5
40
9.3
5.5
105
2
1
4
3
5
progr.
Terminal Assignment
1 free
2N/+
3 free
4 L1 / - (NO)
5 L1 / - (NC)
L1 / -
N/+
AC/DC N/+
L1 / -
AC/DC
NCNO
Dimensions in mm
97
SICK8 007 755.0300
Electrical and mechanical data
20 ... 250 V AC / DC
6.5 V AC / 6 V DC
350 mA AC (... + 50 °C)
250 mA AC (... + 80 °C)
100 mA DC
2.2 A (20 ms / 0.5 Hz)
5 mA
2.5 mA (250 V AC)
1 mA (24 V DC)
approx. 8 ms
1% - 15% of sr
10% of sr
± 10% of sr
to EN 60 947-5-2
Wire-break protection
Short-circuit protection
(pulsed)
Reverse polarity protection
Power-up pulse suppression
Enclosure rating to EN 60529
Protection class
Shock and vibration
stress
Ambient temperature Ta
Housing material
-
-
-
yes
IP 65
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 80 °C
Plastic
Operating voltage Ub
Voltage drop Ud
(at Ia max.)
Continuous current Ia
Peak current IK
Min. load current
Residual current
Time delay before
availability tv
Hysteresis H
Repeatability R
(Ub and Ta constant)
Temperature drift
EMC
Selection table
Sensing
range sn
mm
Installation
in metal Connection Order numberTypeSwitching frequency f
in Hz
IQ80-60NUP-KK0 7902138460 Terminal up to
2.5 mm2
Output
function
progr.
Inductive proximity sensors, IQ 80 series, AC / DC
98 SICK 8 007 755.0300
Connection diagram
Inductive proximity sensors
IM 08 series, sensing range 1 mm
NAMUR, metal housing
3bu
1bn
e.g. isolating unit
EN 2 Ex
+
-
Features
Can be installed flush in metal
NAMUR to EN 50227
High switching frequency
Robust brass housing,
nickel-plated, with fine thread
M8 x 1 mm
Enclosure rating IP 67
PTB classification for
division 1 areas
Ex EEx ib IIC T6
Accessories
Isolating unit EN2Ex
Dimensions in mm
M8x1
13
30
Wire colour Assignment
bn braun brown + V DC
bu blau blue - V DC
99
SICK8 007 755.0300
Electrical and mechanical data
Selection table
Operating voltage Ub
Nominal voltage Un
Power consumption,
attenuated
Power consumption,
unattenuated
Internal capacitance
Internal inductance
Cable resistance
Temperature drift
EMC
5 ... 25 V DC
8.2 V DC
1.0 mA
2.2 mA
80 nF
110 µH
50
W
± 10% of sr
to EN 60 947-5-2
Enclosure rating to EN 60529
Shock and vibration
stress
Ambient temperature Ta
Housing material
Tightening torque
Connection cable
IP 67
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 70 °C
Brass, nickel-plated,
plastic
2.5 Nm
PVC, 2 x 0.14 mm2, blue
Sensing
range sn
mm
Installation
in metal Connection Order number
Version TypeOutput
function Switching
frequency f
in Hz
1 NAMUR 2000 Cable 2 m IM08-01B-N-ZW0 6021123
Inductive proximity sensors, IM 08 series, NAMUR
100 SICK 8 007 755.0300
Connection diagram
Inductive proximity sensors
IM 12 series, sensing range 2 / 4 mm
NAMUR, metal housing
Features
Can be installed flush or
non-flush in metal
NAMUR to EN 50227
High switching frequency
Robust brass housing,
nickel-plated, with fine thread
M12 x 1 mm
Enclosure rating IP 67
PTB classification for
division 1 areas
Ex EEx ia IIC T6
Accessories
Isolating unit EN2Ex
Mounting bracket
e.g. isolating unit
EN 2 Ex
bu
bn
-
+
Dimensions in mm
Wire colour Assignment
bn braun brown + V DC
bu blau blue - V DC
M12x1
17
42
30
M12x1
17
30 2
101
SICK8 007 755.0300
Electrical and mechanical data
Selection table
Operating voltage Ub
Rated voltage Un
Power consumption,
attenuated
Power consumption,
unattenuated
Internal capacitance
Internal inductance
Cable resistance
Temperature drift
EMC
5 ... 25 V DC
8.2 V DC
1.0 mA
2.2 mA
230 nF
380 µH
50
W
± 10% of sr
to EN 60 947-5-2
Short-circuit protected
Reverse polarity protected
Enclosure rating to EN 60529
Shock and vibration
stress
Ambient temperature Ta
Housing material
Tightening torque
Connection cable
yes
yes
IP 67
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 70 °C
Brass, nickel-plated,
plastic
7.0 Nm
PVC, 2 x 0.34 mm2, blue
Sensing
range sn
mm
Installation
in metal Connection Order number
Version TypeOutput
function Switching
frequency f
in Hz
2
4NAMUR
NAMUR 1200
1500 Cable 2 m
Cable 2 m IM12-02B-N-ZW0
IM12-04N-N-ZW0 6021124
6021125
Inductive proximity sensors, IM 12 series, NAMUR
102 SICK 8 007 755.0300
Connection diagram
Inductive proximity sensors
IM 18 series, sensing range 5 / 8 mm
NAMUR, metal housing
Features
Can be installed flush or
non-flush in metal
NAMUR to EN 50227
High switching frequency
Robust brass housing,
nickel-plated, with fine thread
M18 x 1 mm
Enclosure rating IP 67
PTB classification for
division 1 areas
Ex EEx ia IIC T6
Accessories
Isolating unit EN2Ex
Mounting bracket
bu
bn
e.g. isolating unit
EN 2 Ex
-
+
Dimensions in mm
M18x1
M18x1
24
33
8
33
24
Wire colour Assignment
bn braun brown + V DC
bu blau blue - V DC
2
2
103
SICK8 007 755.0300
Electrical and mechanical data
Selection table
Operating voltage Ub
Rated voltage Un
Power consumption,
attenuated
Power consumption,
unattenuated
Internal capacitance
Internal inductance
Cable resistance
Temperature drift
EMC
5 ... 25 V DC
8.2 V DC
1.0 mA
2.2 mA
230 nF (flush)
240 nF (non-flush)
60 µH
50
W
± 10% of sr
to EN 60 947-5-2
Short-circuit protected
Reverse polarity protected
Enclosure rating to EN 60529
Shock and vibration
stress
Ambient temperature Ta
Housing material
Tightening torque
Connection cable
yes
yes
IP 67
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 70 °C
Brass, nickel-plated,
plastic
35 Nm
PVC, 2 x 0.34 mm2, blue
Sensing
range sn
mm
Installation
in metal Connection Order number
Version TypeOutput
function Switching
frequency f
in Hz
5
8NAMUR
NAMUR 720
300 Cable 2 m
Cable 2 m IM18-05B-N-ZW0
IM18-08N-N-ZW0 6021126
6021127
Inductive proximity sensors, IM 18 series, NAMUR
104 SICK 8 007 755.0300
Connection diagram
Inductive proximity sensors
IM 30 series, sensing range 10 / 15 mm
NAMUR, metal housing
Features
Can be installed flush or
non-flush in metal
NAMUR to EN 50227
High switching frequency
Robust brass housing,
nickel-plated, with fine thread
M30 x 1.5 mm
Enclosure rating IP 67
PTB classification for
division 1 areas
Ex EEx ia IIC T6
Accessories
Isolating unit EN2Ex
Mounting bracket
e.g.isolating unit
EN 2 Ex
bu
bn
-
+
Dimensions in mm
M30x1.5 M30x1.5
36
36
15 2
41
41
2
Wire colour Assignment
bn braun brown + V DC
bu blau blue - V DC
105
SICK8 007 755.0300
Electrical and mechanical data
Selection table
Operating voltage Ub
Rated voltage Un
Power consumption,
attenuated
Power consumption,
unattenuated
Internal capacitance
Internal inductance
Cable resistance
Temperature drift
EMC
5 ... 25 V DC
8.2 V DC
1.0 mA
2.2 mA
230 nF (flush)
240 nF (non-flush)
130 µH (flush)
100 µH (non-flush)
50
W
± 10% of sr
to EN 60 947-5-2
Short-circuit protected
Reverse polarity protected
Enclosure rating to EN 60529
Shock and vibration
stress
Ambient temperature Ta
Housing material
Tightening torque
Connection cable
yes
yes
IP 67
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 70 °C
Brass, nickel-plated,
plastic
50 Nm
PVC, 2 x 0.5 mm2, blue
Sensing
range sn
mm
Installation
in metal Connection Order number
Version TypeOutput
function Switching
frequency f
in Hz
10
15 NAMUR
NAMUR 450
200 Cable 2 m
Cable 2 m IM30-10B-N-ZW0
IM30-15N-N-ZW0 6021128
6021129
Inductive proximity sensors, IM 30 series, NAMUR
106 SICK 8 007 755.0300
Operating Principle
Capacitive pr oximity sensors
The oscillator is set in such a way
that it only becomes capable of os-
cillation through this increase in
capacity. The start in oscillation
when an object approaches is
detected by the signal analyser and
output via the signal amplifier.
Reduction factor R
As with the inductive proximity
sensors, the reduction factor
depends on the material. It
describes the factor by which the
sensing range s is reduced by a
certain material, with reference to
the nominal sensing range sn, which
results from the use of an earthed
ST37 metal plate as sensing flag.
The most important reduction
factors for capacitive proximity
sensors are:
iron, earthed 1.0
water 1.0
wheat 0.
(moisture content 12%)
wood 0.7
glass 0.6
oil 0.4
PVC 0.4
PE 0.37
ceramic material 0.3
Sensing flag
Active surface
RC-oscillation circuit Signal analyser Switch amplifier
The active element in a capacitive
proximity sensor consists of a
sensor electrode and shielding.
Together, these two electrodes form
the capacitor.
On the approach of a sensing flag
(metallic or non-metallic object), a
change in capacity takes place in
the electrical field of this capacitor,
i.e. the capacitor of the RC
oscillation circuit is arranged in such
a way that its capacity increases
when an object approaches.
I
U
EMC-overview
Sensing flag
Damped
Undamped
sn
Test Standard Product Generic SICK
Standard Standard Capacitive
EN 60947-5-2 EN 50082-2 Sensors
Electrostatic EN 61000-4-2 4 kV cd / 8 kV ad* 4 kV cd78 kV ad* 17 kV cd/ad*
Discharge ESD (IEC 1000-4-2)
HF radiated EN 61000-4-3 3 V/m 10 V/m < 15 V/m
(IEC 1000-4-3) 80 ... 1000 MHz 80 ... 1000 MHz 80 ... 1000 MHz
HF wire EN 61000-4-6
-
10 V > 10 V
conducted (IEC 1000-4-6) 0,15 ... 80 MHz
Burst EN 61000-4-4 1 kV 2 kV 4 kV
(IEC 1000-4-4)
Surge IEC 255-5 1 kV, 500 Ohm
-
2.5 kV, 500 Ohm
*cd = contact discharge ad = air discharge
107
SICK8 007 755.0300
Selection table/Type code
Capacitive pr oximity sensors
Character 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Stelle
1Sensor technologie
C Capacitive
2Design
M Cylinder with thread
Q Cuboid
C M 3O - 2 5N P P- K WO
CM18
CM30
CQ35
Cable
Connector
DC
DC
DC
complementary
Flush N. flush
8 12
16 25
16 25
Material
Plastic
Plastic
Plastic
Size in mm
M18
M30
35x55x15
Design
with
thread
Cuboid
Page
Connection type Electr.
config.
Outout
function
HousingSeries
108
110
112
Connection 13
W Cable, PVC
C Connector, M12x1
other codes 14
PNP
Switching
output
Sensing range
sn in mm
3/4 Housing shape
18 Diameter
30 or
35 Edge length of
sensing face
6/7/8 Sensing range/
installation
B flush
N non flush
08B 8 mm; flush
25N 25 mm; non flush
Housing material 12
K Plastic
Output 10
P complementary
Interface 9
P DC (3/4-wire) PNP
N DC (3/4-wire) NPN
108 SICK 8 007 755.0300
Capacitive proximity sensors
CM18 series, sensing range 8 / 12 mm
DC 4-wir e, plastic housing
Features
High EMC-immunity
Can be installed flush or
non-flush
PNP output
Adjustable sensing range:
3 to 8 mm (flush),
3 to 12 mm (non flush)
Complementary output function
Short-circuit protection
(pulsed)
Plastic housing with
fine thread M18 x 1 mm
Cable or connector
Enclosure rating IP 67
LED-status indicator
Accessories
Round connector
Mounting bracket
Connection diagram
4bk
2
1
Wire colour Contact Assignment
bn brown 1 + V DC
bk black 4 Schließer
wh white 2 Öffner
bu blue 3 - V DC 4
3
PNP 1bn +
DC
-
2wh
3bu
24
M18x1 M18x1 M18x1 M18x1
LED
846.5 79.5 15.5
846.5
LED
24
91.5
LED
LED
complementary
46.5 71.5 15.5
46.5 83.5
24
24
Potentiometer
Potentiometer
Potentiometer
Potentiometer
M12x1
M12x1
4bk
NPN 1bn +
DC
-
2wh
3bu
complementary
109
SICK8 007 755.0300
Electrical and mechanical data
Capacitive proximity sensors, CM 18 series, DC
Selection table
Operating voltage Ub
Ripple Upp
Voltage drop Ud
Power consumption
(without load)
Continuous current Ia
Time delay before
availability tv
Hysteresis H
Repeatability R
(Ub and Ta constant)
Temperature drift
EMV
10 ... 40 V DC
10% of Ub
2,5 V
10 mA
200 mA
100 ms
4% ... 20% of sr
5% of sr
± 10% of sr
to EN 60 947-5-2
Short circuit protection
(pulsed)
Reverse polarity protection
Power-up pulse suppression
Enclosure rating to EN 60529
Shock und vibration
stress
Ambient temperature Ta
Housing material
Tightening torque
Connection cable
yes
yes
yes
IP 67
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 80 °C
Plastic
2,6 Nm
PVC, 4 x 0.34 mm2
Sensing
range sn
mm
Installation Connection Order numberSwitching
output TypeOutput
function Switching
frequency f
in Hz
8
8
PNP
NPN
30
30
cable 2 m
cable 2 m
CM18-08BPP-KW1
CM18-08BNP-KW1
6020136
6021455
complementary
complementary
complementary
complementary
8
8
PNP
NPN
connector M12 x 1 mm
connector M12 x 1 mm
CM18-08BPP-KC1
CM18-08BNP-KC1
6020388
6021456
30
30
12
12
PNP
NPN
30
30
cable 2 m
cable 2 m
CM18-12NPP-KW1
CM18-12NNP-KW1
6020389
6021457
complementary
complementary
complementary
complementary
12
12
PNP
NPN
connector M12 x 1 mm
connector M12 x 1 mm
CM18-12NPP-KC1
CM18-12NNP-KC1
6020410
6021458
30
30
110 SICK 8 007 755.0300
Capacitive proximity sensors
CM30 series, sensing range 16 / 25 mm
DC 4-wir e, plastic housing
Features
High EMC-immunity
Can be installed flush or
non-flush
PNP output
Adjustable sensing range:
2 to 16 mm (flush),
4 to 25 mm (non flush)
Complementary output function
Short-circuit protection
(pulsed)
Plastic housing with
fine thread M30 x 1.5 mm
Cable or connector
Enclosure rating IP 67
LED-status indicator
Accessories
Round connector
Mounting bracket
Connection diagram
M30x1.5
M30x1.5
M30x1.5
M30x1.5
36
36
M12x1
12 75.6
50
LED
LED
12 50
15.4
50
63.6 15.4
36
LED
91
50 79
36
LED
M12x1
Potentiometer
Potentiometer
Potentiometer
Potentiometer
4bk
2
1
4
3
PNP 1bn +
DC
-
2wh
3bu
complementary
Wire colour Contact Assignment
bn brown 1 + V DC
bk black 4 NO
wh white 2 NC
bu blue 3 - V DC
4bk
NPN 1bn +
DC
-
2wh
3bu
complementary
111
SICK8 007 755.0300
Electrical and mechanical data
Capavitive proximity sensors, CM 30 series, DC
Operating voltage Ub
Ripple Upp
Voltage drop Ud
Power consumption
(without load)
Continuous current Ia
Time delay before
availability tv
Hysteresis H
Repeatability R
(Ub and Ta constant)
Temperature drift
EMV
10 ... 40 V DC
10% of Ub
2,5 V
10 mA
200 mA
100 ms
4% ... 20% of sr
5% of sr
± 10% of sr
to EN 60 947-5-2
Short circuit protection
(pulsed)
Reverse polarity protection
Power-up pulse suppression
Enclosure rating to EN 60529
Shock und vibration
stress
Ambient temperature Ta
Housing material
Tightening torque
Connection cable
Sensing
range sn
mm
Installation Connection Order number
Switching
output TypeOutput
function Switching
frequency f
in Hz
16
16
PNP
NPN
50
50
cable 2 m
cable 2 m
CM30-16BPP-KW1
CM30-16BNP-KW1
6020473
6021459
complementary
complementary
complementary
complementary
16
16
PNP
NPN
connector M12 x 1 mm
connector M12 x 1 mm
CM30-16BPP-KC1
CM30-16BNP-KC1
6020475
6021460
50
50
yes
yes
yes
IP 67
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 80 °C
Plastic
7,5 Nm
PVC, 4 x 0.34 mm2
Selection table
25
25
PNP
NPN
50
50
cable 2 m
cable 2 m
CM30-25NPP-KW1
CM30-25NNP-KW1
6020476
6021461
complementary
complementary
complementary
complementary
25
25
PNP
NPN
connector M12 x 1 mm
connector M12 x 1 mm
CM30-25NPP-KC1
CM30-25NNP-KC1
6020477
6021462
50
50
112 SICK 8 007 755.0300
Capacitive proximity sensors
CQ35 series, sensing range 25 mm
DC 4-wir e, plastic housing
Connection diagram
35
57.5
LED
24.5
55 18
M12x1
M12x1
24.5
35
Potentiometer
LED
55 12
57.5
15
15
Potentiometer
Features
High EMC-immunity
Can be installed flush or
non-flush
PNP output
Adjustable sensing range:
4 to 25 mm (non flush)
Device can be flush mounted,
sensing range: 16 mm
Complementary output function
Short-circuit protection
(pulsed)
Plastic housing
Cable or connector
Enclosure rating IP 67
LED-status indicator
Accessories
Round connector 4bk
2
1
4
3
PNP 1bn +
DC
-
2wh
3bu
complementary
Wire colour Contact Assignment
bn brown 1 + V DC
bk black 4 NO
wh white 2 NC
bu blue 3 - V DC
4bk
NPN 1bn +
DC
-
2wh
3bu
complementary
113
SICK8 007 755.0300
Capacitive proximity sensors, CQ 35 series, DC
Electrical and mechanical data
Selection table
Operating voltage Ub
Ripple Upp
Voltage drop Ud
Power consumption
(without load)
Continuous current Ia
Time delay before
availability tv
Hysteresis H
Repeatability R
(Ub und Ta constant)
Temperature drift
EMV
10 ... 40 V DC
10% of Ub
2,5 V
10 mA
200 mA
100 ms
4% ... 20% of sr
5% of sr
± 10% of sr
to EN 60 947-5-2
Short circuit protection
(pulsed)
Reverse polarity protection
Power-up pulse suppression
Enclosure rating to EN 60529
Shock und vibration
stress
Ambient temperature Ta
Housing material
Connection cable
Sensing
range sn
mm
Installation Connection Order numberSwitching
output TypeOutput
function Switching
frequency f
in Hz
25
25
PNP
NPN
50
50
cable 2 m
cable 2 m
CQ35-25NPP-KW1
CQ35-25NNP-KW1
6020478
6021463
complementary
complementary
yes
yes
yes
IP 67
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 75 °C
Plastic
PVC, 4 x 0.34 mm2
25
25
PNP
NPN
50
50
connector M12 x 1 mm
connector M12 x 1 mm
CQ35-25NPP-KC1
CQ35-25NNP-KC1
6020479
6021464
complementary
complementary
114 SICK 8 007 755.0300
Operating Principle
Magnetic proximity sensors
As with inductive proximity sensors,
magnetic proximity sensors also have
an LC oscillating circuit, a signal
evaluator, and a switching amplifier.
They also have a core (strip) made of
amorphous, highly permeable, and
magnetically soft glass-metal.
This strip attenuates the oscillating
circuit using eddy-current losses. The
core becomes magnetically saturated
very quickly if a magnetic field is
applied, e.g. if a magnet is brought
closer. The eddy-current losses
attenuating the oscillating circuit are
reduced and the oscillating de-
attenuates. The power consumption
of a magnetic proximity sensor
therefore increases as a magnet is
brought closer, in contrast to
inductive proximity sensors where the
oscillator current is reduced as the
switching trigger is brought closer.
For this reason, the starting curves
are not the lines of an electro-
magnetic field, but limit lines which
describe the saturation of the glass-
metal strip by a magnet and the
associated switch-through of the
sensor.
A major advantage of this technology
is that large sensing ranges are
possible even with small sensor
types.
Permanent magnets are usually used
to trigger magnetic proximity sensors.
They comprise magnetically hard
substances - steel alloyed with other
metals such as aluminium, cobalt,
and nickel. Magnetically hard ferrite
with similar properties can be also be
produced from sintered compounds
containing iron oxide and other metal
oxides.
Sensing face
Magnet
N S
LC
Core made of glass-metal
Switching
curve LC oscillating
circuit Switching
amplifier
Signal
evaluator
attenuated
I
U
sn
N S
Magnet
unattenuated
115
SICK8 007 755.0300
Rated response sensitivity
The response sensitivity applies to
both magnetic field poles without
external field interference.
In rooms and industrial plants, external
magnetic fields are caused by the
earth's magnetic field, electrical
conductors, magnetic coils, perma-
nent magnets, and steel objects
containing residual magnetism.
Neighbouring iron parts may increase
external interference or have a
shielding effect. External magnetic
fields are usually constant or
periodically effective and can therefore
be taken into consideration. If
necessary, magnetic shielding plates
must be used or the sensors must be
installed flush in the steel.
Approach curves
In the case of magnetic proximity
sensors, it must be remembered that
the alignment of the magnet relative
to the sensor axis changes the
sensing range. The lines of magnetic
flux have to be in one line with the
core of glass metal.
A distinction can be made between
the following cases:
Sensor and magnet axis are in
alignment with each other.
Case 1
The sensor responds as soon as the
magnet reaches the switching curve.
It can approach the proximity sensor
axially or pass in front of the sensor
inside the sensing range.
Case 2
The sensor responds if the magnet
approaches the switching curve
laterally. If the sensor leaves the
switching curve, the sensor switches
back again. This principle is largely
used for magnetic cylinder sensors.
Glossary
Magnetic proximity sensors
sn
N
S
Switching curve
Magnetic field lines
Direction of movement
Switching curve
Magnetic field lines
Direction of movement
N
S
design response sensitivity
MM08 1,0 mT
MM12 1,0 mT
MM18 0,9 mT
MQ10 1,0 mT
Core of glass metal
Core of glass metal
B [mT]
6
5
3
4
1
2
mm
N S
8050
Magnetic induction
The illustration shows magnetic
induction as a function of the distance
to the actuating magnet. Electric coils
or permanent magnets are used to
adjust the response sensitivity of the
sensors and also for comparative
measurements. An oxide magnet
made of barium ferrite with a 30 mm
diameter and 10 mm in height (M4.0) is
used as the standard measure.
116 SICK 8 007 755.0300
Sensor and magnet axis are
offset by 90°.
Case 3
If the magnet passes radially in front
of the proximity sensor, the sensing
range is smaller than that in the
case 1. If, for example, the sensor
enters the left-hand switching curve
from the right-hand switching curve, it
passes through an area in which the
magnetic field is reversed. This briefly
de-attenuates the proximity sensor
before it is re-attenuated in the left-
hand switching curve. Whether or not
the evaluation unit can detect this
interruption depends on the actuating
speed and the axial distance of the
traversing magnet.
Glossary
Magnetic proximity sensors
Traverse distance Sü
The traverse distance sü is the
distance between the left- and right-
hand boundary of the switching
curve plus the diameter of the
magnet. If a magnet approaches the
switching curve from the left-hand
side, the sensor responds. If the
magnet leaves the switching curve at
the opposite side, the sensor only
switches if the magnet has
completely left the envelope curve.
Case 4
In this case, the magnet passes
through two switching curves. The
magnetic field reverses at the
boundary of these curves and two
switching points are produced. The
detection of this interruption again
depends on the actuating speed and
the radial distance relative to the
sensor axis.
Switching curve
Magnetic field lines
N S N S
sn
Switching curve
Magnetic field lines
Direction of movement
N S
N S
Direction of movement
N
SN
S
Ø Magnet
Switching curve
Traverse distance Sü
Core of glass metal
Core of glass metal
Traverse time tü
tü =
sü = Traverse distance
vü = Traverse velocity
sü
vü
117
SICK8 007 755.0300
Sensing range and
switching curves
The following tables show the
sensing ranges sn and switching
curve diameter ( sD ) relative to the
actuating magnets (M1.0 - M5.0):
Magnet material
M1.0 - Samarium cobalt
( Ø 10 x 3 mm )
M2.0 - AlNiCo
( Ø 6 x 25 mm )
M3.0 - Barium ferrite
( Ø 20 x 6.5 mm )
M4.0 - Barium ferrite
( Ø 30 x 10 mm )
M5.0/5.1 - Barium ferrite
( Ø 30/35 x 15 mm )
The magnet M4.0 is used as the
standard measure.
Series: MM08 - 60 A - ...
MQ10 - 60 A - ...
MM12 - 60 A - ...
Magnet Sn mm
type On Off sD1 mm sD2 mm
M 1.0 23 25 28 23
M 2.0 24 25 30 27
M 3.0 36 37 41 36
M 4.0 60 61 68 60
M 5.0 68 70 80 67
Series: MM18 - 70 A - ...
Magnet Sn mm
type On Off sD1 mm sD2 mm
M 1.0 24 25 30 26
M 2.0 25 26 36 32
M 3.0 38 39 45 40
M 4.0 70 72 75 65
M 5.0 85 87 86 75
sD2
sD1
1/2s
n
2/3s
n
s
n
The difference between Sn "ON" und
Sn "OFF" describes the hysteresis of
each sensor.
118 SICK 8 007 755.0300
Flush sensor installation
Magnetic proximity sensors can be
installed flush in all materials and metals
(with the exception of magnetizable
material) without any detrimental
effects to the sensing range.
Installation Notes
Magnetic proximity sensors
Non-flush sensor installation
The table shows how much the
proximity sensor must protrude when
installed in magnetizable material so
that a reduction in sensing range of
more than 5 % is avoided.
Flush magnet installation
The sensing range is reduced up to
60 % if the magnets are installed in
magnetizable material.
Penetration of material
Since magnetic fields do not
penetrate all non-magnetizable
material, magnetic proximity sensors
can be used to detect magnets e.g.
behind a non-ferrous metal, plastic,
or wooden panel.
NS
NS
a
NS
Standard measure M 4.0
Series a = Free zone (mm)
MM08-60 A-... 10 mm
MM12-60 A-... 10 mm
MM18-70 A-... 15 mm
MQ10-60 A-... 10 mm
Mounting on magnetizable
material
If the magnets are mounted on
magnetizable material, the sensing
range increases to the values printed
in bold in the table below:
Actuating magnets sn mm
Series M 1.0 M 2.0 M 3.0 M 4.0 M 5.0
MM08-60 A-... 23 24 36 60 68
36 32 45 67 73
MM12-60 A-... 23 24 36 60 68
36 32 45 67 73
MM18-70 A-... 24 25 38 70 85
38 35 50 82 95
MQ10-60 A-... 23 24 36 60 68
36 32 45 67 73
NS
NS
119
SICK8 007 755.0300
Selection Table/Type Code
Magnetic proximity sensors
Character 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Character
1Sensor technology
M Magnetic
3/4 Housing size
08 Diameter
10 or
1 2 edge length of
18 sensing face
2Design
H Barrel
M Cylinder with thread
Q Cuboid
MQ 1O-6OA P S-KUO
housing material 12
Z Ms, nickel-plated
K Plastic
MM08
MM12
MM18
MQ10
MM12
MM18
Cable
Connector
DC
DC
DC
DC
NAMUR
NAMUR
NO
NPN
PNP
60
60
70
60
60
70
Material
Brass
Brass
Brass
Plastic
Brass
Brass
Size in mm
M8
M12
M18
10x28/37x16
M12
M18
Form
Cylinder
with
thread
Cuboid
Cylinder
with thread
Page
Connection Electr.
config.
Output
function
Switching
output
Sensing
range
sn in mm
HousingSeries
120
122
124
126
128
130
6/7/8 Sensing range/
magnetic field
6 0 In mm relative to
70 stand. magnet M4.0
A Axial
Connection 13
W Cable, PVC
U Cable, PUR-PVC
T Connector, M8x1
C Connector, M12x1
other codes 14
Output 10
SNO
N NAMUR
Interface 9
P DC (3-wire) PNP
N DC (3-wire) NPN
- NAMUR
120 SICK 8 007 755.0300
Connection diagram
Magnetic proximity sensors
MM 08 series, sensing range 60 mm
DC 3-wire, metal housing
Features
Can be installed flush and
non-flush in metal
Sensing range up to
60 mm
PNP or NPN output
High switching frequency
Short-circuit protection
(pulsed)
Robust brass housing,
nickel-plated with fine thread
M8 x 1 mm
Cable or connector
Enclosure rating IP 67
LED status indicator
Accessories
Round connectors
Magnets 1
4
3
bn
bk
bu
-
DC
+
+
DC
-
1
4
3
bn
bk
bu
PNP
NPN
Wire colour Contact Assignment
bn brown 1 + V DC
bk black 4 NO
bu blue 3 - V DC
4
3
1
M8x1
LED
40 50
13
13
M8x1
59
40
M8x1
LED, 4x90°
Dimensions in mm
121
SICK8 007 755.0300
Electrical and mechanical data
Selection table
Operating voltage Ub
Ripple Upp
Voltage drop Ud
(at Ia max.)
Power consumption
(without load)
Continuous current Ia
Time delay before
availability tv
Hysteresis H
Repeatability R
(Ub and Ta constant)
Temperature drift
EMC
10 ... 30 V DC
10% of Ub
1.5 V
10 mA
300 mA
2 ms
1% - 10% of sr
1% of sr
± 10% of sr
to EN 60 947-5-2
Wire-break protection
Short-circuit protection
(pulsed)
Reverse polarity protection
Power-up pulse suppression
Enclosure rating to EN 60529
Shock and vibration
stress
Ambient temperature Ta
Housing material
Tightening torque
Connection cable
yes
yes
yes
yes
IP 67
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 75 °C
Brass, nickel-plated,
plastic
0.8 Nm (with plastic nuts,
included in package)
2.0 Nm (with metal nuts)
PUR-PVC, 3 x 0.25 mm2
60
60
Sensing
range sn*
mm
Magnetic
alignment Connection Order number
PNP
PNP
Switching
output TypeOutput
function Switching
frequency f
in Hz
5000
5000 Cable 2 m
Connector M8 x 1 mm
MM08-60APS-ZU0
MM08-60APS-ZT0 7900264
7900266
Axial
Axial
Sensing ranges (Typical values)
M 1.0
M 2.0
M 3.0
M 4.0
M 5.0 / 5.1
Magnet type Sensing range sn
Flush installation in magnetizable material
(e.g. iron)
Sensing range sn
Any installation type (flush or non-flush)
in non-magnetizable material
23 mm
24 mm
36 mm
60 mm
68 mm
12 mm
10 mm
15 mm
20 mm
25 mm
Magnetic proximity sensors, MM 08 series, DC
* Sensing range sn based on installation in non-magnetizable material using magnet M 4.0
Output NPN on request
122 SICK 8 007 755.0300
Connection diagram
Magnetic proximity sensors
MM 12 series, sensing range 60 mm
DC 3-wire, metal housing
Features
Can be installed flush and
non-flush in metal
Sensing range up to
60 mm
PNP or NPN output
High switching frequency
Short-circuit protection
(pulsed)
Robust brass housing,
nickel-plated with fine thread
M12 x 1 mm
Cable or connector
Enclosure rating IP 67
LED status indicator
Accessories
Round connectors
Magnets
Mounting bracket 1
4
3
bn
bk
bu
-
DC
+
+
DC
-
1
4
3
bn
bk
bu
PNP
NPN
M12x1
40 10
LED
17
62.5
40 LED, 4x90°
M12x1
17
M12x1
50
Wire colour Contact Assignment
bn brown 1 + V DC
bk black 4 NO
bu blue 3 - V DC
2 free 4
3
2
1
Dimensions in mm
123
SICK8 007 755.0300
Electrical and mechanical data
Selection table
Operating voltage Ub
Ripple Upp
Voltage drop Ud
(at Ia max.)
Power consumption
(without load)
Continuous current Ia
Time delay before
availability tv
Hysteresis H
Repeatability R
(Ub and Ta constant)
Temperature drift
EMC
10 ... 30 V DC
10% of Ub
1.5 V
10 mA
300 mA
2 ms
1% - 10% of sr
1% of sr
± 10% of sr
to EN 60 947-5-2
Wire-break protection
Short-circuit protection
(pulsed)
Reverse polarity protection
Power-up pulse suppression
Enclosure rating to EN 60529
Shock and vibration
stress
Ambient temperature Ta
Housing material
Tightening torque
Connection cable
yes
yes
yes
yes
IP 67
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 75 °C
Brass, nickel-plated,
plastic
7.0 Nm
PUR-PVC, 3 x 0.25 mm2
60
60
Sensing
range sn*
mm
Magnetic
alignment Connection Order number
PNP
PNP
Switching
output TypeOutput
function Switching
frequency f
in Hz
5000
5000 Cable 2 m
Connector M12 x 1 mm
MM12-60APS-ZU0
MM12-60APS-ZC0 7900268
7900270
Axial
Axial
Sensing ranges (Typical values)
M 1.0
M 2.0
M 3.0
M 4.0
M 5.0 / 5.1
Magnet type Sensing range sn
Flush installation in magnetizable material
(e.g. iron)
Sensing range sn
Any installation version (flush or non-flush)
in non-magnetizable material
23 mm
24 mm
36 mm
60 mm
68 mm
17 mm
14 mm
23 mm
37 mm
44 mm
Magnetic proximity sensors, MM 12 series, DC
* Sensing range sn based on installation in non-magnetizable material using magnet M 4.0
Output NPN on request
124 SICK 8 007 755.0300
Connection diagram
Magnetic proximity sensors
MM 18 sensors, sensing range 70 mm
DC 3-wire, metal housing
Features
Can be installed flush and
non-flush in metal
Sensing range up to
70 mm
PNP or NPN output
High switching frequency
Short-circuit protection
(pulsed)
Robust brass housing,
nickel-plated with fine thread
M18 x 1 mm
Cable or connector
Enclosure rating IP 67
LED status indicator
Accessories
Round connectors
Magnets
Mounting bracket 1
4
3
bn
bk
bu
-
DC
+
+
DC
-
1
4
3
bn
bk
bu
PNP
NPN
M18x1
24
LED
40
50
M18x1
24
M12x1
LED, 4x90°
65
40
Wire colour Contact Assignment
bn brown 1 + V DC
bk black 4 NO
bu blue 3 - V DC
2 free 4
3
2
1
Dimensions in mm
125
SICK8 007 755.0300
Electrical and mechanical data
Selection table
Operating voltage Ub
Ripple Upp
Voltage drop Ud
(at Ia max.)
Current consumption
(without load)
Continuous current Ia
Time delay before
availability tv
Hysteresis H
Repeatability R
(Ub and Ta constant)
Temperature drift
EMC
10 ... 30 V DC
10% of Ub
1.5 V
10 mA
300 mA
2 ms
1% - 10% of sr
1% of sr
± 10% of sr
to EN 60 947-5-2
Wire-break protection
Short-circuit protection
(pulsed)
Reverse polarity protection
Power-up pulse suppression
Enclosure rating to EN 60529
Shock and vibration
stress
Ambient temperature Ta
Housing material
Tightening torque
Connection cable
yes
yes
yes
yes
IP 67
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 75 °C
Brass, nickel-plated,
plastic
25 Nm
PUR-PVC, 3 x 0.25 mm2
70
70
Sensing
range sn*
mm
Magnetic
alignment Connection Order number
PNP
PNP
Switching
output TypeOutput
function Switching
frequency f
in Hz
5000
5000 Cable 2 m
Connector M12 x 1 mm
MM18-70APS-ZU0
MM18-70APS-ZC0 7900272
7900274
Axial
Axial
Sensing ranges (Typical values)
M 1.0
M 2.0
M 3.0
M 4.0
M 5.0 / 5.1
Magnet type Sensing range sn
Flush installation in magnetizable material
(e.g. iron)
Sensing range sn
Any installation version (flush or non-flush)
in non-magnetizable material
24 mm
25 mm
38 mm
70 mm
85 mm
20 mm
17 mm
32 mm
55 mm
60 mm
Magnetic proximity sensors, MM 18 series, DC
* Sensing range sn based on installation in non-magnetizable material using magnet M 4.0
Output NPN on request
126 SICK 8 007 755.0300
Connection diagram
Magnetic proximity sensors
MQ 10 series, sensing range 60 mm
DC 3-wire, plastic housing
1
4
3
bn
bk
bu
-
DC
+
+
DC
-
1
4
3
bn
bk
bu
PNP
NPN
Wire colour Contact Assignment
bn brown 1 + V DC
bk black 4 NO
bu blue 3 - V DC
4
3
1
Features
Can be installed flush and
non-flush in metal
Sensing range up to
60 mm
PNP or NPN output
High switching frequency
Short-circuit protection
(pulsed)
Plastic housing
Cable or connector
Enclosure rating IP 67
LED status indicator
Accessories
Round connectors
Magnets
Dimensions in mm
10.3
5.7 LED
28
Ø3.2
LED
22.2
3.4
3.2
2.9 16
10.3
2.9
10.3
5.7
M8x1
LED, 4x90°
28 37
M8x1
LED, 4x90°
Ø3.2
3.4
2.9
3.2
10.3
16
22.2 2.9
127
SICK8 007 755.0300
Electrical and mechanical data
Selection table
Operating voltage Ub
Ripple Upp
Voltage drop Ud
(at Ia max.)
Power consumption
(without load)
Continuous current Ia
Time delay before
availability tv
Hysteresis H
Repeatability R
(Ub and Ta constant)
Temperature drift
EMC
10 ... 30 V DC
10% of Ub
1.5 V
10 mA
300 mA
2 ms
1% - 10% of sr
1% of sr
± 10% of sr
to EN 60 947-5-2
Wire-break protection
Short-circuit protection
(pulsed)
Reverse polarity protection
Power-up pulse suppression
Enclosure rating to EN 60529
Shock and vibration
stress
Ambient temperature Ta
Housing material
Connection cable
yes
yes
yes
yes
IP 67
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 75 °C
Plastic
PUR-PVC, 3 x 0.25 mm2
60
60
60
60
Sensing
range sn*
mm
Magnetic
alignment Connection Order number
PNP
NPN
PNP
NPN
Switching
output TypeOutput
function Switching
frequency f
in Hz
5000
5000
5000
5000
Cable 2 m
Cable 2 m
Connector M8 x 1 mm
Connector M8 x 1 mm
MQ10-60APS-KU0
MQ10-60ANS-KU0
MQ10-60APS-KT0
MQ10-60ANS-KT0
7900278
7900279
7900280
7900281
Axial
Axial
Axial
Axial
Sensing ranges (Typical values)
M 1.0
M 2.0
M 3.0
M 4.0
M 5.0 / 5.1
Magnet type Sensing range sn
Flush installation in magnetizable material
(e.g. iron)
Sensing range sn
Any installation version (flush or non-flush)
in non-magnetizable material
23 mm
24 mm
36 mm
60 mm
68 mm
12 mm
10 mm
15 mm
20 mm
25 mm
* Sensing range sn based on installation in non-magnetizable material using magnet M 4.0
Magnetic proximity sensors, MQ 10 series, DC
128 SICK 8 007 755.0300
Connection diagram
Magnetic proximity sensors
MM 12 series, sensing range 60 mm
NAMUR, metal housing
Features
Can be installed flush and
non-flush in metal
Sensing ranges up to
60 mm
NAMUR to EN 50 227
High switching frequency
Robust brass housing,
nickel-plated, with fine thread
M12 x 1 mm
Cable or connector
Enclosure rating IP 67
LED status indicator
Classification
TÜV 99 ATEX 1398
Ex EExibII CT6
Accessories
Round connectors
Magnets
Mounting bracket
Isolating unit EN 2 Ex
17
LED
4050
M12x1
LED, 4x90°
17
M12x1
62.5
40
M12x1
e.g. isolating unit
EN 2 Ex
4bu
1bn
Wire colour Contact Assignment
bn brown 1 + V DC
bu blue 4 - V DC
3 free
2 free 4
3
2
1
-
+
Dimensions in mm
129
SICK8 007 755.0300
Electrical and mechanical data
Selection table
60
60
Sensing
range sn*
mm
Magnetic
alignment Connection Order number
NAMUR
NAMUR
Version TypeOutput
function Switching
frequency f
in Hz
5000
5000 Cable 2 m
Connector M12 x 1 mm
MM12-60A-N-ZW0
MM12-60A-N-ZC0 7900286
7900287
Axial
Axial
Sensing ranges (Typical values)
M 1.0
M 2.0
M 3.0
M 4.0
M 5.0 / 5.1
Magnet type Sensing range sn
Flush installation in magnetizable material
(e.g. iron)
Sensing range sn
Any installation version (flush or non-flush)
in non-magnetizable material
23 mm
24 mm
36 mm
60 mm
68 mm
17 mm
14 mm
23 mm
37 mm
44 mm
Operating voltage Ub
Rated voltage Un
Ripple Upp
Power consumption,
attenuated
Power consumption,
unattenuated
Internal capacitance
Internal inductance
Cable resistance
Time delay before
availability tv
Hysteresis H
Repeatability R
(Ub and Ta constant)
Temperature drift
EMC
5 ... 25 V DC
8.2 V DC
5% of Ub
2.5 mA
1.0 mA
45nF
30 µH
50
W
2 ms
1% - 10% of sr
1% of sr
± 10% of sr
to EN 60 947-5-2
Short-circuit protected
Reverse-polarity protected
Enclosure rating to EN 60529
Shock and vibration
stress
Ambient temperature Ta
Housing material
Tightening torque
Connection cable
yes
yes
IP 67
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 70 °C
Brass, nickel-plated,
plastic
7.0 Nm
PVC, 2 x 0.34 mm2, blue
* Sensing range sn based on installation in non-magnetizable material using magnet M 4.0
Magnetic proximity sensors, MM 12 series, NAMUR
130 SICK 8 007 755.0300
Connection diagrams
Magnetic proximity sensors
MM 18 series, sensing range 70 mm
NAMUR, metal housing
Features
Can be installed flush and
non-flush in metal
Sensing ranges up to
70 mm
NAMUR to EN 50 227
High switching frequency
Robust brass housing,
nickel-plated, with fine thread
M18 x 1 mm
Cable or connector
Enclosure rating IP 67
LED status indicator
Classification
TÜV 99 ATEX 1398
Ex EExibII CT6
Accessories
Round connectors
Magnets
Mounting bracket
Isolating unit EN 2 Ex
1
M18x1
M18x1
LED
24
24
40
50
M12x1
65
40 LED, 4x90°
e.g. isolating unit
EN 2 Ex
4bu
1bn
Wire colour Contact Assignment
bn brown 1 + V DC
bu blue 4 - V DC
3 free
2 free 4
3
2
1
-
+
Dimensions in mm
131
SICK8 007 755.0300
Electrical and mechanical data
Selection table
70
70
Sensing
range sn*
mm
Magnetic
alignment Connection Order number
NAMUR
NAMUR
Version TypeOutput
function Switching
frequency f
in Hz
5000
5000 Cable 2 m
Connector M12 x 1 mm
MM18-70A-N-ZW0
MM18-70A-N-ZC0 7900288
7900289
Axial
Axial
Sensing ranges (Typical values)
M 1.0
M 2.0
M 3.0
M 4.0
M 5.0 / 5.1
Magnet type Sensing range sn
Flush installation in magnetizable material
(e.g. iron)
Sensing range sn
Any installation version (flush or non-flush)
in non-magnetizable material
24 mm
25 mm
38 mm
70 mm
85 mm
20 mm
17 mm
32 mm
55 mm
60 mm
Operating voltage Ub
Rated voltage Un
Ripple Upp
Power consumption,
attenuated
Power consumption,
unattenuated
Internal capacitance
Internal inductance
Cable resistance
Time delay before
availability tv
Hysteresis H
Repeatability R
(Ub and Ta constant)
Temperature drift
EMC
5 ... 25 V DC
8.2 V DC
5% of Ub
2.5 mA
1.0 mA
45 nF
30 µH
50
W
2 ms
1% - 10% of sr
1% of sr
± 10% of sr
to EN 60 947-5-2
Short-circuit protected
Reverse polarity protected
Enclosure rating to EN 60529
Shock and vibration
stress
Ambient temperature Ta
Housing material
Tightening torque
Connection cable
yes
yes
IP 67
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 70 °C
Brass, nickel-plated,
plastic
25 Nm
PVC, 2 x 0.34 mm2, blue
* Sensing range sn based on installation in non-magnetizable material using magnet M 4.0
Magnetic proximity sensors, MM 18 series, NAMUR
132 SICK 8 007 755.0300
Operating Principle
Magnetic cylinder sensors
Magnetic cylinder sensors are used
to detect the position of pistons in
pneumatic cylinders. They are
attached directly to the cylinder body
and operate according to the same
principle as for magnetic proximity
sensors.
They detect a ring magnet in the
piston through the housing wall
made of non-magnetizable material
(aluminium, brass, stainless steel).
Response sensitivity
The magnetic induction of pneumatic
cylinders is between 5 and 25
mTesla. A response sensitivity of
3 mTesla is enough to ensure signal
triggering.
The sensitivity of 3 mT is a guide
value which depunds on the design
of the cylinder.
Traverse distance sü
The traverse distance sü is between
5 and 20 mm, depending on the
cylinder's construction (wall thick-
ness, diameter, and magnetic
induction). The typical hysteresis is
1 mm and remains constant.
Magnetic cylinder sensor
Actuating area
Ring magnet
Cylinder tube made of
non-magnetizable material
Actuating speed
The short response times of the
sensors allow actuating speeds of
up to 5 m/s.
133
SICK8 007 755.0300
Product Overview
Magnetic cylinder sensors
MZ Z1
Mounting on tie-
rod cylinders with
max. rod diameter
of 10 mm
Page 140
MZ Z2
Mounting on tie-
rod cylinders with
max. rod diameter
of 12.5 mm
Page 142
MZ K1, K3
Mounting on
cylinders with
dovetail slot
Page 148
MZ R1
Mounting on
round-body cylinders
Ø 8...63 mm using
mounting clamp
Page 136
MZ R2
Mounting on
round-body cylinders
Ø 8 ... 100 mm using
clamping band
Page 138
MZ P3
Mounting on
integrated profile
cylinders with max.
rod diameter
of 14 mm
Page 144
MZ P4
Mounting on
integrated profile
cylinders with max.
rod diameter
of 18 mm
Page 146
MZ F1
Mounting in T-slot
Page 152
134 SICK 8 007 755.0300
Product Overview
Magnetic cylinder sensors
MZT 1
Mounting in T-slot.
Mountable from the top.
Page 154
Magnet actuated indicator systems like the magnetic cylinder sensors for
pneumatic cylinders can be disturbed by strong magnetic fields. In weld
environments this kind of magnetic field can occur. The magnetic cylinder
sensors of series MZU2 are equipped with an interference field sensor to detect
these interference fields caused by AC-, DC- or medium frequency welders.
The response sensivity of the interference detector is > 2 mT and locks the
output during the welding process at the last known state. When the welding
process stops, the sensor updates the output accordingly.
MZU 2 weld immune Version
Mounting on different cylinder types
Page 158
135
SICK8 007 755.0300
Character 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Character
1Sensor technology
M Magnetic
R Reed switch
MZ R1-O3V P S-A UO
Type Code
Magnetic cylinder sensors
2Design
Z Cylinder sensor
3/4 Application
R1 Round-body cylinder
R2 Round-body cylinder
Z1 Tie-rod cylinder
Z2 Tie-rod cylinder
P3 Integrated Profile
cylinder
P4 Integrated Profile
cylinder
K1 Short-stroke cylinder
K3 Short-stroke cylinder
F1 T-slot
U2 Universal
T1 T-Nut
other codes 14
M Weld immune
housing material 12
A Aluminium
K Plastic
D Die-cast zinc
T Die-cast zinc
with teflon coating
Connection 13
W Cable, PVC
U Cable, PUR-PVC
P Cable with connector, M8x1
T Connector, M8x1
C Connector, M12x1
Output 10
SNO
N NAMUR
Interface 9
P DC (3-wire) PNP
N DC (3-wire) NPN
U AC/DC 2-wire
R Reed (3-wire)
- NAMUR
6/7/8 Response sensitivity,
sensor position
0 2 in mT
03 in mT
V Sensor, front
Z Sensor, centre
136 SICK 8 007 755.0300
Features
Non-contact determination of
piston position in pneumatic
cylinders
Mounting on round-body
cylinders Ø 8 ... 63 mm using
R1 mounting clamp
High response sensitivity
3 mT
Frontal sensing face
No secondary switching
ranges
High repeat accuracy
Actuating speed 5 m/s
PNP or NPN output
Short-circuit protection
(pulsed)
Solid aluminium housing
Cable or connector
Enclosure rating IP 67
LED status indicator
Accessories
Round connectors
Connection diagram
Wire colour Contact Assignment
bn brown 1 + V DC
bk black 4 NO
bu blue 3 - V DC
Magnetic cylinder sensors
MZ R1 series
DC 3-wir e, for round-body cylinders
1
4
3
bn
bk
bu
13
4
-
DC
+
+
DC
-
1
4
3
bn
bk
bu
PNP
NPN
Dimensions in mm
30
M8x1
30
37
LED
LED
Ø8
Ø8
137
SICK8 007 755.0300
Operating voltage Ub
Ripple Upp
Voltage drop Ud
(at Ia max.)
Power consumption
(without load)
Continuous current Ia
Time delay before
availability tv
Hysteresis H
Repeatability R
(Ub and Ta constant)
EMC
Electrical and mechanical data
10 ... 30 V DC
10% of Ub
1.5 V
10 mA
300 mA
2 ms
1.0 mm
0.1 mm
to EN 60 947-5-2
Wire-break protection
Short-circuit protection
(pulsed)
Reverse polarity protection
Power-up pulse suppression
Enclosure rating to EN 60529
Shock and vibration
stress
Ambient temperature Ta
Housing material
Connection cable
7900592
7900593
7900594
7900595
Cable 2 m
Cable 2 m
Connector M8 x 1 mm
Connector M8 x 1 mm
3
3
3
3
yes
yes
yes
yes
IP 67
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 75 °C
Aluminium, plastic
PUR-PVC, 3 x 0.25 mm2
Selection table
Response
sensitivity
in mT
Sensing
face Connection Order number
PNP
NPN
PNP
NPN
Switching
output
MZR1-03VPS-AU0
MZR1-03VNS-AU0
MZR1-03VPS-AT0
MZR1-03VNS-AT0
Type
Output
function Switching
frequency f
in Hz
5000
5000
5000
5000
Series is available as reed switch on request.
Accessories
Ø 4
d1
d2
3
10
Mounting clamp
Plastic
for magnetic cylinder sensor R1
with d1 Ø 8 mm
For cylinders with Clamping range Type Order-Nr.
piston diameter d2 in mm
18 mm 19,2 ... 10,0 BEF-S-R1-08 7902337
10 mm 10,9 ... 12,0 BEF-S-R1-10 7901753
12 mm 12,9 ... 14,0 BEF-S-R1-12 7901754
16 mm 16,9 ... 18,0 BEF-S-R1-16 7901755
20 mm 21,0 ... 22,0 BEF-S-R1-20 7901756
25 mm 26,1 ... 27,2 BEF-S-R1-25 7901757
32 mm 33,0 ... 35,0 BEF-S-R1-32 7901758
40 mm 41,4 ... 42,5 BEF-S-R1-40 7901759
50 mm 52,5 ... 54,0 BEF-S-R1-50 7901760
63 mm 66,0 ... 67,0 BEF-S-R1-63 7901761
Magnetic cylinder sensors, MZ R1 series, DC
138 SICK 8 007 755.0300
Connection diagram
Wire colour Contact Assignment
bn brown 1 + V DC
bk black 4 NO
bu blue 3 - V DC
Magnetic cylinder sensors
MZ R2 series
DC 3-wir e, for round-body cylinders
1
4
3
bn
bk
bu
-
DC
+
+
DC
-
1
4
3
bn
bk
bu
PNP
NPN
31
Features
Non-contact determination of
piston position in pneumatic
cylinders
Universal mounting using
clamping band for max.
cylinder diameter of 100 mm
High response sensitivity
3 mT
Frontal sensing face
No secondary switching ranges
High repeat accuracy
Actuating speed
5 m/s
PNP or NPN output
Short-circuit protection
(pulsed)
Solid aluminium housing
Cable or connector
Enclosure rating IP 67
LED status indicator
Accessories
Round connectors
4
Dimensions in mm
12
12 7
M8x1
30
30
LEDLED
12
12
139
SICK8 007 755.0300
Electrical and mechanical data
Operating voltage Ub
Ripple Upp
Voltage drop Ud
(at Ia max.)
Power consumption
(without load)
Continuous current Ia
Time delay before
availability tv
Hysteresis H
Repeatability R
(Ub and Ta constant)
EMC
10 ... 30 V DC
10% of Ub
1.5 V
10 mA
300 mA
2 ms
1.0 mm
0.1 mm
to EN 60 947-5-2
Wire-break protection
Short-circuit protection
(pulsed)
Reverse polarity protection
Power-up pulse suppression
Enclosure rating to EN 60529
Shock and vibration
stress
Ambient temperature Ta
Housing material
Connection cable
yes
yes
yes
yes
IP 67
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 75 °C
Aluminium, plastic
PUR-PVC, 3 x 0.25 mm2
Magnetic cylinder sensors, MZ R2 series, DC
Response
sensitivity
in mT
Sensing
face Switching
output Output
function Switching
frequency f
in Hz
7900598
7900599
7900600
7900601
MZR2-03VPS-AU0
MZR2-03VNS-AU0
MZR2-03VPS-AT0
MZR2-03VNS-AT0
5000
5000
5000
5000
PNP
NPN
PNP
NPN
Type Order number
Selection table
Connection
Cable 2 m
Cable 2 m
Connector M8 x 1 mm
Connector M8 x 1 mm
3
3
3
3
8
d
5
Accessories
Clamping band
stainless steel
for magnetic cylinder sensor R2
For cylinder range Clamping range Type Order-No.
with piston diameter d in mm
8 ... 16 mm 118 - 29 BEF-S-R2-16 7901762
20/25 mm 128 - 39 BEF-S-R2-25 7901763
32 mm 138 - 49 BEF-S-R2-30 7901764
40 mm 148 - 59 BEF-S-R2-40 7901765
50 mm 158 - 69 BEF-S-R2-50 7901766
63 mm 168 - 79 BEF-S-R2-63 7901767
80 mm 88 - 99 BEF-S-R2-80 7901768
100 mm 98 - 109 BEF-S-R2-100 7901769
140 SICK 8 007 755.0300
Connection diagram
Magnetic cylinder sensors
MZ Z1 series
DC 3-wir e, for tie-rod cylinders
Wire colour Contact Assignment
bn brown 1 + V DC
bk black 4 NO
bu blue 3 - V DC
2 free
Features
Non-contact determination of
piston position in pneumatic
cylinders
Tie-rod mounting for
max. rod diameter of 10 mm
High response sensitivity
3 mT
Frontal sensing face
No secondary switching
ranges
High repeat accuracy
Actuating speed 5 m/s
PNP or NPN output
Short-circuit protection
(pulsed)
Solid aluminium housing
with integrated mounting claw
Cable or connector
Enclosure rating IP 67
LED status indicator
Accessories
Round connectors
1
4
3
bn
bk
bu
-
DC
+
+
DC
-
1
4
3
bn
bk
bu
PNP
NPN
4
3
2
1
Dimensions in mm
M6
23
30
LED
M12x1
58°
68°
10.5
15
515 5
16,5
58°
15
10,5
68°
M12x1
16,5
2334
30
LED
M6
55
15
30
30
141
SICK8 007 755.0300
Electrical and mechanical data
Selection table
Operating voltage Ub
Ripple Upp
Voltage drop Ud
(at Ia max.)
Power consumption
(without load)
Continuous current Ia
Time delay before
availability tv
Hysteresis H
Repeatability R
(Ub and Ta constant)
EMC
10 ... 30 V DC
10% of Ub
1.5 V
10 mA
300 mA
2 ms
1.0 mm
0.1 mm
of EN 60 947-5-2
Wire-break protection
Short-circuit protection
(pulsed)
Reverse polarity protection
Power-up pulse suppression
Enclosure rating to EN 60529
Shock and vibration
stress
Ambient temperature Ta
Housing material
Connection cable
yes
yes
yes
yes
IP 67
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 75 °C
Aluminium, plastic
PUR-PVC, 3 x 0.25 mm2
3
3
3
Response
sensitivity
in mT
Sensing
face Connection Order number
PNP
PNP
NPN
Switching
output TypeOutput
function Switching
frequency f
in Hz
5000
5000
5000
Cable 2 m
Connector M12 x 1 mm
Connector M12 x 1 mm
MZZ1-03VPS-AU0
MZZ1-03VPS-AC0
MZZ1-03VNS-AC0
7900606
7900608
7900609
Magnetic cylinder sensors, MZ Z1 series, DC
142 SICK 8 007 755.0300
Connection diagram
Magnetic cylinder sensors
MZ Z2 series
DC 3-wir e, for tie-rod cylinders
Wire colour Contact Assignment
bn brown 1 + V DC
bk black 4 NO
bu blue 3 - V DC
2 free
1
4
3
bn
bk
bu
-
DC
+
+
DC
-
1
4
3
bn
bk
bu
PNP
NPN
4
3
2
1
M12x1 M12x1
LED
M6
13
23
LED
35 37.5 14
M6
13
2312.5
12.5
35 37.5 14
32
Features
Non-contact determination of
piston position in pneumatic
cylinders
Mounting on tie-rods
with max. rod diameter of
12.5 mm
High response sensitivity
3 mT
Frontal or central sensing face
No secondary switching
ranges
High repeat accuracy
Actuating speed 5 m/s
PNP or NPN output
Short-circuit protection
(pulsed)
Solid aluminium construction
with integrated mounting and
plastic housing
Cable or connector
Enclosure rating IP 67
LED status indicator
Accessories
Round connectors
Dimensions in mm
143
SICK8 007 755.0300
Electrical and mechanical data
Selection table
Operating voltage Ub
Ripple Upp
Voltage drop Ud
(at Ia max.)
Power consumption
(without load)
Continuous current Ia
Time delay before
availability tv
Hysteresis H
Repeatability R
(Ub and Ta constant)
EMC
10 ... 30 V DC
10% of Ub
1.5 V
10 mA
300 mA
2 ms
1.0 mm
0.1 mm
to EN 60 947-5-2
Wire-break protection
Short-circuit protection
(pulsed)
Reverse polarity protection
Power-up pulse suppression
Enclosure rating to EN 60529
Shock and vibration
stress
Ambient temperature Ta
Housing material
Connection cable
yes
yes
yes
yes
IP 67
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 75 °C
Aluminium, plastic
PUR-PVC, 3 x 0.25 mm2
3
3
3
Response
sensitivity
in mT
Sensing
face Connection Order number
PNP
NPN
PNP
Switching
output TypeOutput
function Switching
frequency f
in Hz
5000
5000
5000
Cable 2 m
Cable 2 m
Connector M12 x 1 mm
MZZ2-03ZPS-KU0
MZZ2-03ZNS-KU0
MZZ2-03ZPS-KC0
7900618
7900619
7900620
Magnetic cylinder sensors, MZ Z2 series, DC
3
3PNP
PNP 5000
5000 Cable 2 m
Connector M12 x 1 mm
MZZ2-03VPS-KU0
MZZ2-03VPS-KC0 7900622
7900624
144 SICK 8 007 755.0300
Connection diagram
Magnetic cylinder sensors
MZ P3 series
DC 3-wir e, for integrated profile cylinders
Wire colour Contact Assignment
bn brown 1 + V DC
bk black 4 NO
bu blue 3 - V DC
2 free
Features
Non-contact determination of
piston position in pneumatic
cylinders
Mounting on integrated profile
with max. width of 14 mm
High response sensitivity
3 mT
Frontal sensing face
No secondary switching
ranges
High repeat accuracy
Actuating speed 5 m/s
PNP output
Short-circuit protection
(pulsed)
Solid aluminium housing
with integrated mounting claw
Cable or connector
Enclosure rating IP 67
LED status indicator
Accessories
Round connectors
1
4
3
bn
bk
bu
-
DC
+
+
DC
-
1
4
3
bn
bk
bu
PNP
NPN
4
13
2
Dimensions in mm
82°
82°
23
15
25.4
M6
5
7
5
515
30
82°
82°
23
25.4
M12x1
LED
30
M6
5
7
55
15
15
37.3
M12x1
37.3
LED
145
SICK8 007 755.0300
Electrical and mechanical data
Selection table
Operating voltage Ub
Ripple Upp
Voltage drop Ud
(at Ia max.)
Power consumption
(without load)
Continuous current Ia
Time delay before
availability tv
Hysteresis H
Repeatability R
(Ub and Ta constant)
EMC
10 ... 30 V DC
10% of Ub
1.5 V
10 mA
300 mA
2 ms
1.0 mm
0.1 mm
to EN 60 947-5-2
Wire-break protection
Short-circuit protection
(pulsed)
Reverse polarity protection
Power-up pulse suppression
Enclosure rating to EN 60529
Shock and vibration
stress
Ambient temperature Ta
Housing material
Connection cable
yes
yes
yes
yes
IP 67
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 75 °C
Aluminium, plastic
PUR-PVC, 3 x 0.25 mm2
3
3
Response
sensitivity
in mT
Sensing
face Connection Order number
PNP
PNP
Switching
output TypeOutput
function Switching
frequency f
in Hz
5000
5000 MZP3-03VPS-AU0
MZP3-03VPS-AC0 7900610
7900612
Cable 2 m
Connector M12 x 1 mm
Magnetic cylinder sensors, MZ P3 series, DC
146 SICK 8 007 755.0300
Connection diagram
Magnetic cylinder sensors
MZ P4 series
DC 3-wir e, for integrated profile cylinders
Wire colour Contact Assignment
bn brown 1 + V DC
bk black 4 NO
bu blue 3 - V DC
2 free
Features
Non-contact determination of
piston position in pneumatic
cylinders
Mounting on integrated profile
with max. width of 18 mm
High response sensitivity
3 mT
Frontal sensing face
No secondary switching
ranges
High repeat accuracy
Actuating speed 5 m/s
PNP output
Short-circuit protection
(pulsed)
Solid aluminium housing
with integrated mounting claw
Cable or connector
Enclosure rating IP 67
LED status indicator
Accessories
Round connectors
1
4
3
bn
bk
bu
-
DC
+
+
DC
-
1
4
3
bn
bk
bu
PNP
NPN
4
13
2
Dimensions in mm
78°
32
78°40.8
33.5
6
M6
15
55
30
78°
32
78°
6
15
55
LED
M12x1
30
40.8
33.5
M6
M12x1
LED
19
19
147
SICK8 007 755.0300
Electrical and mechanical data
Selection table
Operating voltage Ub
Ripple Upp
Voltage drop Ud
(at Ia max.)
Power consumption
(without load)
Continuous current Ia
Time delay before
availability tv
Hysteresis H
Repeatability R
(Ub and Ta constant)
EMC
10 ... 30 V DC
10% of Ub
1.5 V
10 mA
300 mA
2 ms
1.0 mm
0.1 mm
to EN 60 947-5-2
Wire-break protection
Short-circuit protection
(pulsed)
Reverse polarity protection
Power-up pulse suppression
Enclosure rating to EN 60529
Shock and vibration
stress
Ambient temperature Ta
Housing material
Connection cable
yes
yes
yes
yes
IP 67
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 75 °C
Aluminium, plastic
PUR-PVC, 3 x 0.25 mm2
3
3
Response
sensitivity
in mT
Sensing
face Connection Order number
PNP
PNP
Switching
output TypeOutput
function Switching
frequency f
in Hz
5000
5000 Cable 2 m
Connector M12 x 1 mm
MZP4-03VPS-AU0
MZP4-03VPS-AC0 7900614
7900616
Magnetic cylinder sensors, MZ P4 series, DC
148 SICK 8 007 755.0300
Features
Non-contact determination of
piston position in pneumatic
cylinders
Simple mounting on
short-stroke cylinders
High response sensitivity
2 mT
Frontal sensing face
No secondary switching
ranges
High repeat accuracy
Actuating speed 5 m/s
PNP output
Short-circuit protection
(pulsed)
Solid aluminium housing
with special profile and
clamping screw
Cable or connector
Enclosure rating IP 67
LED status indicator
Accessories
Round connectors
Connection diagram
Wire colour Contact Assignment
bn brown 1 + V DC
bk black 4 NO
bu blue 3 - V DC
Magnetic cylinder sensors
MZ K1 series
DC 3-wire, for short-stroke cylinders
1
4
3
bn
bk
bu
-
DC
+
+
DC
-
1
4
3
bn
bk
bu
PNP
NPN
13
4
Dimensions in mm
M8x1
M8x1
LED LED
1.8
8.5
13.5
13.5
10
11110 1
13.5
13.5
8.5
26
13
M3
1.8
14.3
M3
13 26
7
14.3
88
149
SICK8 007 755.0300
Electrical and mechanical data
Selection table
Operating voltage Ub
Ripple Upp
Voltage drop Ud
(at Ia max.)
Power consumption
(without load)
Continuous current Ia
Time delay before
availability tv
Hysteresis H
Repeatability R
(Ub and Ta constant)
EMC
10 ... 30 V DC
10% of Ub
1.5 V
10 mA
300 mA
2 ms
1.0 mm
0.1 mm
to EN 60 947-5-2
Wire-break protection
Short-circuit protection
(pulsed)
Reverse polarity protection
Power-up pulse suppression
Enclosure rating to EN 60529
Shock and vibration
stress
Ambient temperature Ta
Housing material
Connection cable
yes
yes
yes
yes
IP 67
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 75 °C
Aluminium, plastic
PUR-PVC, 3 x 0.25 mm2
Cable 2 m
Connector M8 x 1 mm
2
2
Response
sensitivity
in mT
Sensing
face Connection Order number
PNP
PNP
Switching
output TypeOutput
function Switching
frequency f
in Hz
5000
5000 MZK1-02VPS-AU0
MZK1-02VPS-AT0 7900602
7900604
Magnetic cylinder sensors, MZ K1 series, DC
150 SICK 8 007 755.0300
Features
Non-contact determination of
piston position in pneumatic
cylinders
Mountable from the top
Simple mounting on
short-stroke cylinders
High response sensitivity
2 mT
Frontal sensing face
No secondary switching
ranges
High repeat accuracy
Actuating speed 5 m/s
PNP or NPN output
Short-circuit protection
(pulsed)
Solid aluminium housing
with special profile and
clamping screw
Cable
Enclosure rating IP 67
LED status indicator
Accessories
Round connectors
Connection diagram
Wire colour Contact Assignment
bn brown 1 + V DC
bk black 4 NO
bu blue 3 - V DC
Magnetic cylinder sensors
MZ K3 series
DC 3-wire, for short-stroke cylinders
1
4
3
bn
bk
bu
-
DC
+
PNP
13
4
Dimensions in mm
M8x1
M8x1
LED
1.8
8.5
13.5
10
1
M3
13 26
714.3
8
14
151
SICK8 007 755.0300
Electrical and mechanical data
Selection table
Operating voltage Ub
Ripple Upp
Voltage drop Ud
(at Ia max.)
Power consumption
(without load)
Continuous current Ia
Time delay before
availability tv
Hysteresis H
Repeatability R
(Ub and Ta constant)
EMC
10 ... 30 V DC
10% of Ub
1.5 V
10 mA
300 mA
2 ms
1.0 mm
0.1 mm
to EN 60 947-5-2
Wire-break protection
Short-circuit protection
(pulsed)
Reverse polarity protection
Power-up pulse suppression
Enclosure rating to EN 60529
Shock and vibration
stress
Ambient temperature Ta
Housing material
Connection cable
yes
yes
yes
yes
IP 67
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 75 °C
Aluminium, plastic
PUR-PVC, 3 x 0.25 mm2
Connector M8 x 1 mm
2
Response
sensitivity
in mT
Sensing
face Connection Order number
PNP
Switching
output TypeOutput
function Switching
frequency f
in Hz
5000 MZK3-02VPS-AT0 7901952
Magnetic cylinder sensors, MZ K3 series, DC
152 SICK 8 007 755.0300
Features
Non-contact determination of
piston position in pneumatic
cylinders
For T-slot
High response sensitivity
3 mT
Frontal sensing face
No secondary switching
ranges
High repeat accuracy
Actuating speed 5 m/s
PNP output
Short-circuit protection
(pulsed)
Plastic housing with T-profile
and clamping screw
Connection cable or
connector on cable
Enclosure rating IP 67
LED status indicator
Magneto-resistive element
Accessories
Round connectors
Connection diagram
Wire colour Contact Assignment
bn brown 1 + V DC
bk black 4 NO
bu blue 3 - V DC
Magnetic cylinder sensors
MZ F1 series
DC 3-wir e, for T-slot
1
4
3
bn
bk
bu
-
DC
+
PNP
13
4
Dimensions in mm
LED
6
3.2
LED
M3
6.7
30
34
M8x1
2
5.3
L=250
153
SICK8 007 755.0300
Electrical and mechanical data
Selection table
Operating voltage Ub
Ripple Upp
Voltage drop Ud
(at Ia max.)
Power consumption
(without load)
Continuous current Ia
Time delay before
availability tv
Hysteresis H
Repeatability R
(Ub and Ta constant)
EMC
10 ... 30 V DC
10% of Ub
2 V
10 mA
150 mA
2 ms
1.5 mm
0.2 mm
to EN 60 947-5-2
Wire-break protection
Short-circuit protection
(pulsed)
Reverse polarity protection
Power-up pulse suppression
Enclosure rating to DIN 40050
Shock and vibration
stress
Ambient temperature Ta
Housing material
Connection cable
Connection cable w. M8x1 mm
yes
yes
yes
yes
IP 67
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 75 °C
Plastic
PUR-PVC, 3 x 0.25 mm2
PUR
Response
sensitivity
in mT
Sensing
face Connection Order number
Switching
output TypeOutput
function Switching
frequency f
in Hz
5000
5000
5000
MZF1-03VPS-KU0
MZF1-03VPS-KUB
MZF1-03VPS-KP0
Cable 2 m
Cable 5 m
Cable with M8 x 1 mm
PNP
PNP
PNP
3
3
3
7900596
7903147
7900597
Series is available as reed switch on request.
Magnetic cylinder sensors, MZ F1 series, DC
SICK
154 8 007 755.0300
Magnetic cylinder sensors
MZT1 series
DC 3-wir e, for T-slot cylinder
Features
Non-contact detection of
piston position in pneumatic
cylinders
Mountable from the top
For all common used T-slot
cylinder e.g. Festo, SMC
Response sensivity 3 mT
Plastic housing with clamping
screw
Connection cable or
connector on cable
Enclosure rating IP 67
LED status indicator
Magneto-resistive element
Accessories
Round connector Connection diagram
4.6
LED M3
27.7
30.5
6.2
36
L = 234
Wire colour Contact Assignment
bn brown 1 + V DC
bk black 4 NO
bu blue 3 - V DC
1
4
3
bn
bk
bu
-
DC
+
PNP
13
4
M8x1
Dimensions in mm
SICK 155
8 007 755.0300
Electrical and mechanical data
Operating voltage Ub
Ripple Uss
Voltage drop Ud
Power consumption
(without load)
Continuous current Ia
Time delay before
availability tv
Hysteresis H
Repeatability R
(Ub and Ta constant)
EMC
10 ... 30 V DC
10% of Ub
2 V
10 mA
100 mA
2 ms
1,5 mm
0,2 mm
to EN 60 947-5-2
Wire-break protection
Short-circuit protection
(pulsed)
Reverse polarity protection
Power-up pulse suppression
Enclosure rating to EN 60529
Shock and vibration
stress
Ambient temperature Ta
Housing material
Connection cable 2 m
Connection cable with M8x1 mm
yes
yes
yes
yes
IP 67
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 75 °C
Plastic PA12
PVC, 3 x 0,14 mm2
PUR
1016809
1016910
Cable 2 m
Cable w. M8 x1 mm
3
3
Selection table
Response
sensivity
in mT
Sensing
face Connection Order
number
PNP
PNP
Switching-
output
MZT1-03VPS-KW0
MZT1-03VPS-KP0
Type
Output
function Switching
frequency
in Hz
5000
5000
Magnetic cylinder sensors, MZ T1 series, DC
SICK
156 8 007 755.0300
Magnetic cylinder sensors
RZT1 series
Reed AC/DC 3-wire, for T-slot
Features
Non-contact detection of
piston position in pneumatic
cylinders
Mountable from the top
For all common used T-slot
cylinder e.g. Festo, SMC
Response sensivity 3 mT
Plastic housing with clamping
screw
Connection cable or
connector on cable
Enclosure rating IP 67
LED status indicator
Accessories
Round connector Connection diagramm
Wire colour Contact Assignment
bn brown 1 + (
-
)
bk black 4 NO
bu blue 3
-
(+)
1
4
3
bn
bk
bu
-
/+
AC/DC
+/
-
13
4
Dimensions in mm
4.6
LED M3
27.7
30.5
6.2
36
L = 234
M8x1
SICK 157
8 007 755.0300
Electrical and mechanical data
1016911
1016912
Cable 2 m
Cable w. M8 x 1 mm
3
3
Selection table
Response
sensivity
in mT
Sensing
face Connection Order
number
Reed
Reed
Version
RZT1-03ZRS-KW0
RZT1-03ZRS-KP0
Type
Output-
function Switching
frequency
in Hz
400
400
Operating voltage Ub
Max. switching power
Continuous current Ia
Switching delay ON
OUT
Hysteresis H typ.
Repeatability R
(Ub und Ta constant)
EMC
10 ... 30 V AC/DC
6 W / VA
500 mA
app. 1,5 ms
app. 0,5 ms
1,5 mm
0,2 mm
to EN 60 947-5-2
Enclosure rating to EN 60529
Shock and
vibration stress
Ambient temperature Ta
Housing material
Connection cable 2 m
Connection cable with
M8x1 mm connector
IP 67
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 75 °C
Plastic PA12
PVC, 3 x 0,14 mm2
PUR
Magnetic cylinder sensors, RZT1 series, AC/DC
158 SICK 8 007 755.0300
Features
Non-contact detection of
piston position in pneumatic
cylinders in weld field
environments
Weld immune in all welding
applications (AC, DC and
medium frequency)
Response sensitivity of
interference field detector
2 mT
The sensors locks the output
during the welding process.
When the welding process
stops, the sensor updates the
output accordingly
Flexible mounting technique
for different cylinder styles
Solid metal housing in
die-cast zinc, optional with
teflon coating
Actuating speed < 1m/s
2 LED`s
Status indicator: yellow
Function indicator: green
Accessories
Round connector
Round connector welding
splatter resistant
Connection diagram
Magnetic cylinder sensors
MZ U2 series
DC 3-wir e, weld immune version
Dimensions in mm
48
28
23
95.5
M4
M12x1
30.5 7.5
18
LED
11
PNP
-
DC
+
1
4
3
Contact Assignment
1 + V DC
4NO
3 - V DC
2 free
24
1
3
159
SICK8 007 755.0300
Electrical and mechanical data
Operating voltage Ub
Ripple Upp
Voltage drop Ud
(at Ia max.)
Power consumption
Continuous current Ia
Time delay before
availability tv
Hysteresis H
Repeatability R
(Ub and Ta constant)
EMC
10 ... 30 V DC
10% of Ub
2.0 V
18 mA (unattenuated)
32 mA (attenuated)
300 mA
20 ms
1.5 mm
0.1 mm
to EN 60 947-5-2
Wire-break protection
Short-circuit protection
(pulsed)
Reverse polarity protection
Power-up pulse suppression
Enclosure rating to DIN 60529
Shock and vibration
stress
Ambient temperature Ta
Housing material
yes
yes
yes
yes
IP 67
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 75 °C
Die-cast zinc, optional
with teflon coating
Magnetic cylinder sensors, MZ U2 series, DC
8,8
8,8
3,1
4,4
0,7
9
7,4
3,1 2,6
14,5
11
4,2
23,7
40,1
6
15
54
4,1
7,25
M6
Mounting clamp for pneumatic cylinder sensor MZU2
Mounting clamp: BEF-KS-U2-S1
Material: die-cast zinc
Order-No.: 4030922
Mounting clamp: BEF-KS-U2-S1T
Material: die-cast zinc with teflon coating
Order-No.: 4031632
Tie-rod cylinder Ø 4 .. 20 mm
Mounting clamp: BEF-KS-U2-P1
Material: aluminium
Order-No.: 2019824
Integrated profile cylinder with max. rod diameter of 13 mm
Mounting clamp: BEF-KS-U2-P2
Material: aluminium
Order-No.: 2019823
Integrated profile cylinder with max. rod diameter of 18 mm
Mounting clamp: BEF-KS-U2-T1
Material: Aluminium
Order-No.: 2019822
Cylinder with T-slot
18,1
43
7,25
4,1
3,5
9
M6
4,5
15
29,5
29,5
10,8
10
43
33,5
Accessories
40
40 MZU2-03VPS-DCM
MZU2-03VPS-TCM*
Connector M12x1 mm
Connector M12x1 mm
3
31017450
1017451
Switching
frequency f
in Hz
Selection table
Response
sensitivity
in mT
Sensing
face Connection Order number
Switching
output TypeOutput
function
PNP
PNP
* with teflon coating
160 SICK 8 007 755.0300
Connection diagram
Magnetic cylinder sensors
MZ R2 series
NAMUR 2-wir e, for round-body cylinders
e.g. isolating unit
EN 2 Ex
1
3
bn
bu
Wire colour Contact Assignment
bn brown 1 + V DC
bu blue 3 - V DC
4 free 13
4
+
-
Features
Non-contact determination of
piston position in pneumatic
cylinders
Universal mounting with
clamping band for max.
cylinder diameter of 100 mm
High response sensitivity
3 mT
Frontal sensing face
No secondary switching
ranges
High repeat accuracy
Actuating speed 5 m/s
NAMUR to EN 50 227
Short-circuit protection
Solid aluminium housing
Cable or connector
Enclosure rating IP 67
LED status indicator
Classification
TÜV 99 ATEX 1398
Ex EExibII CT6
Accessories
Round connectors
Isolating unit EN 2 Ex
Dimensions in mm
12
LED
30
12
161
SICK8 007 755.0300
Electrical and mechanical data
Operating voltage Ub
Rated voltage Un
Ripple Upp
Power consumption,
attenuated
Power consumption,
unattenuated
Internal capacitance
Internal inductance
Cable resistance
Time delay before
availability tv
Hysteresis H
Repeatability R
(Ub and Ta constant)
Temperature drift
EMC
5 ... 25 V DC
8.2 V DC
5% of Ub
2.5 mA
1.0 mA
45nF
30 µH
50
W
2 ms
1.0 mm
0.1 mm
± 0.005 mm / °C
to EN 60 947-5-2
Short-circuit protection
Reverse polarity protection
Enclosure rating to EN 60529
Shock and vibration
stress
Ambient temperature Ta
Housing material
Connection cable
yes
yes
IP 67
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 70 °C
Aluminium, plastic
PVC, 2 x 0.34 mm2, blue
Magnetic cylinder sensors, MZ R2 series, NAMUR
Selection table
Response
sensitivity
in mT
Sensing
face Connection Order numberVersion TypeOutput
function Switching
frequency f
in Hz
3 NAMUR Cable 2 m MZR2-03V-N-AW0 79013215000
8
d
5
Accessories
Clamping band
stainless steel
for magnetic cylinder sensor R2
For cylinder range Clamping range Type Order-No.
with piston diameter d in mm
8 ... 16 mm 118 - 29 BEF-S-R2-16 7901762
20/25 mm 128 - 39 BEF-S-R2-25 7901763
32 mm 138 - 49 BEF-S-R2-30 7901764
40 mm 148 - 59 BEF-S-R2-40 7901765
50 mm 158 - 69 BEF-S-R2-50 7901766
63 mm 168 - 79 BEF-S-R2-63 7901767
80 mm 88 - 99 BEF-S-R2-80 7901768
100 mm 98 - 109 BEF-S-R2-100 7901769
162 SICK 8 007 755.0300
Connection diagram
Magnetic cylinder sensors
MZ Z1 series
NAMUR 2-wir e, for tie-rod cylinders
Features
Non-contact determination of
piston position in pneumatic
cylinders
Mounting of tie-rods with
max. rod diameter of 10 mm
High response sensitivity
3 mT
Frontal sensing face
No secondary switching
ranges
High repeat accuracy
Actuating speed 5 m/s
NAMUR to EN50 227
Solid aluminium construction
with integrated mounting claw
Cable or connector
Enclosure rating IP 67
LED status indicator
Classification
TÜV 99 ATEX 1398
Ex EExibII CT6
Accessories
Round connectors
Wire colour Contact Assignment
bn brown 1 + V DC
bu blue 4 - V DC
2 free
3 free
e.g. isolating unit
EN 2 Ex
M6
23
30
LED
M12x1
58°
68°
10.5
15
515 5
16.5
58°
15
10.5
68°
M12x1
16.5
2336
M6
4
13
2
1
4
bn
bu
30
LED
15
55
30
30
+
-
Dimensions in mm
163
SICK8 007 755.0300
Electrical and mechanical data
Selection table
Operating voltage Ub
Rated voltage Un
Ripple Upp
Power consumption,
attenuated
Power consumption,
unattenuated
Internal capacitance
Internal inductance
Cable resistance
Time delay before
availability tv
Hysteresis H
Repeatability R
(Ub and Ta constant)
Temperature drift
EMC
5 ... 25 V DC
8.2 V DC
5% of Ub
2.5 mA
1.0 mA
45nF
30 µH
50
W
2 ms
1.0 mm
0.1 mm
± 0.005 mm / °C
to EN 60 947-5-2
Short-circuit protected
Reverse polarity protected
Enclosure rating to EN 60529
Shock and vibration
stress
Ambient temperature Ta
Housing material
Connection cable
yes
yes
IP 67
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 70 °C
Aluminium, plastic
PVC, 2 x 0.34 mm2, blue
Response
sensitivity
in mT
Sensing
face Connection Order number
Version TypeOutput
function
3
3NAMUR
NAMUR
Switching
frequency f
in Hz
MZZ1-03V-N-AW0
MZZ1-03V-N-AC0 7901323
7901324
5000
5000 Cable 2 m
Connector M12 x 1 mm
Magnetic cylinder sensors, MZ Z1 series, NAMUR
164 SICK 8 007 755.0300
Connection diagram
Magnetic cylinder sensors
MZ P3 series
NAMUR 2-wire, for integrated profile cylinders
Features
Non-contact determination of
piston position in pneumatic
cylinders
Mounting on integrated profile
with max. width of 14 mm
High response sensitivity
3 mT
Frontal sensing face
No secondary switching
ranges
High repeat accuracy
Actuating speed
5 m/s
NAMUR to EN 50 227
Solid aluminium housing
with integrated mounting claw
Cable or connector
Enclosure rating IP 67
LED status indicator
Classification
TÜV 99 ATEX 1398
Ex EExibII CT6
Accessories
Round connectors
Isolating unit EN 2 Ex
Wire colour Contact Assignment
bn brown 1 + V DC
bu blue 4 - V DC
2 free
3 free
82°
82°
23
15
25.4
M6
5
7
5
515
30
82°
82°
23
25.4
15
M12x1
M12x1
LED
LED
M6
15 5
4
13
2
1
4
bn
bu
e.g. isolating unit
EN 2 Ex
30
5
5
7
37.3
37.3
+
-
Dimensions in mm
165
SICK8 007 755.0300
Electrical and mechanical data
Selection table
Operating voltage Ub
Rated voltage Un
Ripple Upp
Power consumption,
attenuated
Power consumption,
unattenuated
Internal capacitance
Internal inductance
Cable resistance
Time delay before
availability tv
Hysteresis H
Repeatability R
(Ub and Ta constant)
Temperature drift
EMC
5 ... 25 V DC
8.2 V DC
5% of Ub
2.5 mA
1.0 mA
45nF
30 µH
50
W
2 ms
1.0 mm
0.1 mm
± 0.005 mm / °C
to EN 60 947-5-2
Short-circuit protected
Reverse polarity protected
Enclosure rating to EN 60529
Shock and vibration
stress
Ambient temperature Ta
Housing material
Connection cable
yes
yes
IP 67
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 70 °C
Aluminium, plastic
PVC, 2 x 0.34 mm2, blue
Response
sensitivity
in mT
Sensing
face Connection Order number
Version TypeOutput
function Switching
frequency f
in Hz
3
3NAMUR
NAMUR 5000
5000 Cable 2 m
Connector M12 x 1 mm
7901440
7901441
MZP3-03V-N-AW0
MZP3-03V-N-AC0
Magnetic cylinder sensors, MZ P3 series, NAMUR
166 SICK 8 007 755.0300
Connection diagram
Magnetic cylinder sensors
MZ P4 series
NAMUR 2-wire, for integrated profile cylinders
Features
Non-contact determination of
piston condition in pneumatic
cylinders
Mounting on integrated profile
with max. width of 18 mm
High response sensitivity
3 mT
Frontal sensing face
No secondary switching
ranges
High repeat accuracy
Actuating speed 5 m/s
NAMUR to DIN19234
Solid aluminium housing
with integrated mounting claw
Cable or connector
Enclosure rating IP 67
LED status indicator
Classification
TÜV 99 ATEX 1398
Ex EExibII CT6
Accessories
Round connectors
Isolating unit EN 2 Ex
e.g. isolating unit
EN 2 Ex
78°
32
78°40.8
33.5
19
6
M6
15
55
LED
30
78°
32
78°
6
5
33.5
M12x1
5
4
13
2
4bu
Wire colour Contact Assignment
bn brown 1 + V DC
bu blue 4 - V DC
2 free
3 free
15
M6
M12x1
LED
30
19
40.8
+
-
1bn
Dimensions in mm
167
SICK8 007 755.0300
Electrical and mechanical data
Selection table
Response
sensitivity
in mT
Sensing
face Connection Order number
Version TypeOutput
function
3
3NAMUR
NAMUR Cable 2 m
Connector M12 x 1 mm
Switching
frequency f
in Hz
MZP4-03V-N-AW0
MZP4-03V-N-AC0 7901329
7901330
Operating voltage Ub
Rated voltage Un
Ripple Upp
Power consumption,
attenuated
Power consumption,
unattenuated
Internal capacitance
Internal inductance
Cable resistance
Time delay before
availability tv
Hysteresis H
Repeatability R
(Ub and Ta constant)
Temperature drift
EMC
5 ... 25 V DC
8.2 V DC
5% of Ub
2.5 mA
1.0 mA
45nF
30 µH
50
W
2 ms
1.0 mm
0.1 mm
± 0.005 mm / °C
to EN 60 947-5-2
Short-circuit protected
Reverse polarity protected
Enclosure rating to EN 60529
Shock and vibration
stress
Ambient temperature Ta
Housing material
Connection cable
yes
yes
IP 67
30 g, 11 ms
10 to 55 Hz, 1 mm
- 25 ... + 70 °C
Aluminium, plastic
PVC, 2 x 0.34 mm2, blue
5000
5000
Magnetic cylinder sensors, MZ P4 series, NAMUR
168 SICK 8 007 755.0300
Features
Universal supply voltage
3 inputs
VDE protection class II
Power-on indication
Status indicator
Housing with snap-on
mounting for support rail
DIN 46277
Adjustable response delay
Adjustable release delay
Connection diagram
200
100
0
Ia in mA
uu °C
+20 +30 +40 +50 +60
Temperature derating
90...130 V AC
200...264 V AC
25 927
2811 29 13 31 15 32
30
17 18 X1 X2 X4X3 21 22 7824
26
10 KW 1) 10 KW 1) 10 KW 1)
IN1-+ IN2-+ IN3-+ OUT1-+
NL+V
0 V
EN 2
+10...30 V
0 V
OUT
SENSOR 1
+10...30 V
0 V
OUT
SENSOR 2
+10...30 V
0 V
OUT
SENSOR 3
1) External pull-up resistor
required for NPN variants
2
38
5
6
4
7
1
1
DIP switches F 1...8
Indicator IN 1
Indicator IN 2
Indicator IN 3
Indicator OUT
Release delay
Response delay
Power indicator
8
7
6
5
4
3
2
1
98,8
90
70
1
0
35
53
60
58
10...30 V DC
264 V
240 V
253 V
230 V
Dimensions in mm
Accessories Control unit EN 2
169
SICK8 007 755.0300
Technical data
90...130 V AC or 200...264 V AC; 10...30 V DC 2)
48...62 Hz
approx. 40 VA
24 V DC ± 25%
220 mA, see temperature derating curve
Terminal 32 (OUT 1)
PNP
100 mA, short-circuit protected, LED flashes if short-circuit occurs
10 kHz
Terminals 7, 8, 24
250 V AC
2 A
10 Hz
Terminals 26 (IN 1) and 28 (IN 2) and 30 (IN 3), suitable for PNP, NPN1)
and B sensor outputs
10...30 V DC
>10 V DC
< 6 V DC
> 5 µs
See Truth table/Functional diagrams/t1, t2: adjustable from 0.005 to 1 s
IP 20
-25...+55 °C
-40...+70 °C
IEC 68, Part 2...6
IEC 801
approx. 400 g
Operating voltage Ub
System frequency
Power consumption
Outputs
Rated supply voltage
Output current (total) Ia
Transistor output
Type
Switching current
Switching frequency
Relay output
Switching voltage
Switching current
Switching frequency
Inputs
Input voltage
HIGH
LOW
Min. power-up time
Time delays, logics
VDE protection class
Enclosure rating to DIN 40050
Ambient temperature Ta
Storage temperature
Shock, vibration
EMC
Weight
1) External pull-up resistor 10k required for NPN variant
2) When supplied: AC 200...264 V, can be upgraded using jumpers
Order No. 6009654
Control unit EN 2
170 SICK 8 007 755.0300
Overview of functions
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
F3
F5
F7
F8
F6
F4
F1
F2
F8 = 0
F1 = 0 F2 = 0
1
0
1
0
F*)
OUT
F*)
OUT
F1 = 1 F2 = 0
1
0
1
0
F*)
OUT
F1 = 1 F2 = 1
1
0
1
0
F*)
OUT
The time delay t 1 is started with the first rising edge of F*). If a further rising
edge along F*) occurs within t 1, OUT is set for the duration of t 2 and time
delay t 1 is simultaneously retriggered. All subsequent rising edges along
F*), if they occur during t 1, retrigger both t 1 and t 2. t 2 must usually be
set greater than t 1. If t 1 (but not t 2) has elapsed, t 2 is not retriggered by
the next rising edge along F*).
With the setting t 2 t 1, this function provides a frequency discriminator:
If the period T of the input frequency along F*) is less than t 1, OUT remains
set to high; if T is or becomes greater than t 1, OUT remains or becomes
low.
The output OUT follows F*) with a response and release delay. F*) must
be high for at least t 1 so that OUT reacts. t 1 is reset by low of F*). OUT
responds when t 1 has elapsed, oscillator f. t 1 is stopped. If F*) is then
low again, t 2 begins to run after which OUT becomes inactive. If F*) runs
high again during t 2, t 2 is reset and begins to run again when F*) = low.
Both times, t1 and t2, can therefore be retriggered.
The output OUT follows F*) (the logic operation for inputs IN1, IN 2, and
IN 3) without delay.
F*) logic operation of inputs: F = f (IN 1, IN 2, IN 3)
t1 t2 t1 t2
F1 = 0 F2 = 1
1
0
1
0
t1 t1 t1
t1 t1 t1 t1 t1t2
t1
t2
t1
t1
The output OUT has a rising edge from F*) for the duration of t 1. This time
cannot be retriggered here.
IN 1 normal
IN 1 inverse
f (IN 1, IN 2) = IN 1 ÷ IN 2
f (IN 1, IN 2) = IN 1 x IN 2
IN 2 normal
IN 2 inverse (F 8 = 0) (F 8 = 1)
f (IN 1, IN 2, IN 3) = IN 3 ÷ f (IN 1, IN 2) IN 3 normal
f (IN 1, IN 2, IN 3) = IN 3 x f (IN 1, IN 2) IN 3 inverse
OUT normal (F 4 = 0)
OUT inverse (F 4 = 1)
No delay Mo 1 Mo `1
Response and release delay Mo 2 Mo `2
Dynamically delayed Mo 3 Mo `3
Frequency discriminator Mo 4 Mo `4
171
SICK8 007 755.0300
Overview of functions
F8 = 1 F 4 = 0
F 1 = 0 F 2 = 0
Mo 1 F*)
IN 3
OUT
1
0
1
0
1
0
F 1 = 0 F 2 = 1
Mo 2 F*)
IN 3
OUT
1
0
1
0
1
0
F 1 = 1 F 2 = 0
Mo 3 F*)
IN 3
OUT
1
0
1
0
1
0
F 1 = 1 F 2 = 1
Mo 4 F*)
IN 3
OUT
1
0
1
0
1
0
F 1 = 0 F 2 = 0
Mo `1 F*)
IN 3
OUT
1
0
1
0
1
0
F 1 = 1 F 2 = 1
Mo `2 F*)
IN 3
OUT
1
0
1
0
1
0
F 1 = 1 F 2 = 0
Mo `3 F*)
IN 3
OUT
1
0
1
0
1
0
F 1 = 1 F 2 = 1
Mo `4 F*)
IN 3
OUT
1
0
1
0
1
0
F 4 = 1
If during the rising edge of IN 3 the operation F*) is high, this edge sets the output OUT for
the time t 1.
If during the falling edge of F*) IN 3 is not high, the output is set for the duration of t 1.
If F*) is not high with a rising edge along IN 3, the falling edge of IN 3 sets the output for the
time t 1.
If no rising edge along F*) occurs during the high time of IN 3, at the falling edge of IN 3 the
output is set for the duration of t 1.
A rising edge along F*) sets the output; a rising edge along IN 3 resets it. (Edge-controlled
RS-flipflop)
If during the falling edge of F*) IN 3 is high, the output is set for the duration of t 1. (I.e. as
for Mo 2, only IN 3 used as inverse)
If F*) was high with a rising edge along IN 3, the falling edge along IN 3 sets the output for
the time t 1. (As for Mo 3, F*) used as inverse)
If during the high-time of IN 3 a rising edge along F*) occurs, with the falling edge of IN 3 the
output is set for the duration of t 1.
t1 t1 t1
t1 t1
t1 t1 t1
t1 t1
t1 t1
t1 t1 t1
t1 t1
Control unit EN 2
172 SICK 8 007 755.0300
Ebene1
optic
electronic
optic
electronic
red yellow
Features
Reliable electrical isolation
between input, output, and
supply voltage to VDE 0100
Part 410
2-channel each with one
relay output 1 x u
Invertible outputs
Conformity certificate
PTB-No. EX.-95.C.20003X
Intrinsically safe inputs
to [EEex ia] IIC
Power-on and status
indicators
Housing with snap-on
mounting for support rail
DIN 46277
Suitable for zone 0, FRG: 1
Description of operating elements
Switch to reverse action
Switch in position I and contact in input circuit closed, output active (ON).
Switch in position II, output action inverted.
LED (red), cable monitoring indicator.
Activation of cable-break and cable-short-circuit monitoring is only functional if a
proximity switch to DIN 50227 or NAMUR, or a mechanical contact with suitable
resistance circuit as per the operating instructions is connected. This circuit monitors
the input current and deactivates the output with input currents < 0.3 mA cable-break /
and > 6.5 mA short-circuit - irrespective of the setting for the direction of action.
LED (yellow), status indicator.
This LED is actuated at the same time as the output.
LED (green), voltage supply indicator.
Connection diagram
1
87
1
1
2
4
3
42
102
EN 2 Ex-2
2
107
22
3
4
Dimensions in mm
Accessories Isolating unit EN 2 Ex
+
-
+
-
4
5
6
1
2
3
7
8
9
10
11
12
+13 (L) AC
-15 (N)
EN 2 EX
Ex-area
173
SICK8 007 755.0300
Transmission behaviour
With fault in
input circuit
Direction of
action
Normal
Normal
Inverse
Inverse
Normal
Inverse
Normal
Inverse
Normal
Inverse
Normal
Inverse
Cable
monitoring
Any
Any
Any
Any
On
On
On
On
Off
Off
Off
Off
Relay
Released
Picked up
Picked up
Released
Released
Released
Released
Released
Released
Picked up
Picked up
Released
Switching status,
yellow LED
Off
On
On
Off
Off
Off
Off
Off
Off
On
On
Off
Cable
monitoring,
red LED
Off
Off
Off
Off
On
On
On
On
Off
Off
Off
Off
Without fault in
input circuit
Ind. proximity sensor attenuated
Magn. proximity sensor unattenuated
Ind. proximity sensor unattenuated
Magn. proximity sensor attenuated
Ind. proximity sensor attenuated
Magn. proximity sensor unattenuated
Ind. proximity sensor unattenuated
Magn. proximity sensor attenuated
Cable-break
Cable-break
Short-circuit
Short-circuit
Cable-break
Cable-break
Short-circuit
Short-circuit
Input
Direction of action: reversible (see table)
Line monitoring: can be deactivated
Max. switching frequency: 20 Hz
Switching function table
Isolating unit EN 2Ex
Technical data EN 2 Ex -1 -2 -3
Part No.
Supply voltage Vs
Powert frequency
Line consumption
Inputs
Idling voltage
Switching points
Short-circuit current
Permitted external capacity
Permitted external inductivity
Switching outputs 1)
Switching voltage U max.
Switching current I max.
Switching capacity P max.
Explosion protection
VDE protection class
Degree of protection
Ambient operating temperature Tu
Storage temperature
Weight
1) Intended as spark suppression suitable for inductive or capacitive load
6010459 6010460 6009944
AC 115 V AC 230 V DC 24 V
48 to 62 Hz -
approx. 1.5 VA per channel 0.7 W
for 1 or 2 sensors
DC 8.5 V
0 I 1.55 mA, 1 I 1.75 mA
I 6 mA
max. 567 nF
max. 5 mH
One relay per input: 1 x u
AC 250 V
5A
100 VA
[EEx ia] IIC
I
IP 20
-25 to +60 °C
-25 to +85 °C
250 g
174 SICK 8 007 755.0300
Accessories
Round connectors adjustable
Cable receptacle, straight design
DOS-0803-G
M8 Order-No. 7902077
connectable cable: Ø 4-5 mm / 0,25 mm2; 0,34 mm2
DOS-1204-G
M12 Order-No. 6007302
connectable cable: Ø 4-6 mm / max. 0,75 mm2
Cable receptacle, angled design
DOS-0803-W
M8 Order-No. 7902078
connectable cable: Ø 4-5 mm / 0,25 mm2; 0,34 mm2
DOS-1204-W
M12 Order-No. 6007303
connectable cable: Ø 4-6 mm / max. 0,75 mm2
60
M12
Ø20
Ø12
M8
38
M8
36
35
23
30,5
Ø20
M12
Ø12
M8
175
SICK8 007 755.0300
Accessories
Accessories
Round connectors with integral cable
(1) bn (4) bk
(3) bu
M8
Straight design
DOL-0803-G02M
PVC, 3 x 0,25 mm2, 2 m
M8 Order-No. 6010785
DOL-0803-G05MB
PUR, 3 x 0,25 mm2, 5 m
M8 Order-No. 7902080
DOL-1204-G02M
PVC, 4 x 0,25 mm2, 2 m
M12 Order-No. 6009382
DOL-1204-G05M
PVC, 4 x 0,25 mm2, 5 m
M12 Order-No. 6009866
DOL-1204-G05MB
PUR, 3 x 0,34 mm2, 5 m
M12 Order-No. 7902084
DOL-1204-G10M
PVC, 4 x 0,25 mm2, 10 m
M12 Order-No. 6010543
M12
(2) wt (3) bu
(1) bn (4) bk
(3) bu (4) bk
(2) wt (1) bn
DOL-1204-W05ME
PUR/PVC, 4 x 0,34 mm2, 5 m
with LED`s for power and output indication,
PNP-complementary
M12 Order-No. 6020398 M12
LED
Angled design
DOL-0803-W02M
PVC, 3 x 0,25 mm2, 2 m
M8 Order-No. 6008489
DOL-0803-W05MB
PUR, 3 x 0,25 mm2, 5 m
M8 Order-No. 7902081
DOL-1204-W02M
PVC, 4 x 0,25 mm2, 2 m
M12 Order-No. 6009383
DOL-1204-W05M
PVC, 4 x 0,25 mm2, 5 m
M12 Order-No. 6009867
DOL-1204-W05MD
PVC, 4 x 0,34 mm2, 5 m, welding splatter resistant
M12 Order-No. 6020399
DOL-1204-W05MB
PUR, 3 x 0,34 mm2, 5 m
M12 Order-No. 7902085
DOL-1204-W10M
PVC, 4 x 0,25 mm2, 10 m
M12 Order-No. 6010541
M12
(1) bn
(2) wt
(3) bu (4) bk
M8
(4) bk (1) bn
8,5
(3) bu
176 SICK 8 007 755.0300
Accessories
Magnets
3
Ø10
Magnet M 2.0
MAG-0625-A, AlNiCo
temperature resistance
-100 °C to +450 °C
Order-No. 7901783
25
Ø6
Magnet M 3.0
MAG-2006-B, Barium ferrite
temperature resistance
-25 °C to +130 °C
Order-No. 7901784
6.5
Ø4.3
Ø20
Magnet M 4.0
MAG-3010-B, Barium ferrite
temperature resistance
-25 °C to +130 °C
Order-No. 7901785
10
Ø30
Magnet M 5.0
MAG-3015-B, Barium ferrite
temperature resistance
-25 °C to +130 °C
Order-No. 7901786
Magnet M 5.1
MAG-3515-B, Barium ferrite with
plastic jacket
Order-No. 7902086
15
Ø31
Ø5.3
Ø36
Ø5.3
19,5
Magnet M 1.0
MAG-1003-S, Samarium cobalt
temperature resistance
-50 °C to +180 °C
Order-No. 7901782
177
SICK8 007 755.0300
Accessories
BEF-WN-M12
Mounting bracket for M12
(M3 screws not included)
metal
Order-No. 5308447
BEF-WN-M18
Mounting bracket for M18
(M4 screws not included)
metal
Order-No. 5308446
BEF-WN-M30
Mounting bracket for M30
(M5 screws not included)
metal
Order-No. 5308445
Accessories
Mounting brackets
42
45
50
14
37
30
14
30
30
20
10
26.515 12.2
1.5
36.520 18.2
1.5
30 30.4
2.5
55
Slot for
M3 screw
Slot for
M4 screw
Slot for
M5 screw
178 SICK 8 007 755.0300
Index
Type designation
Type designation Order No. Page
CM 18 - 08B P P - K C 1 6020388 108
CM 18 - 08B P P - K W 1 6020136 108
CM 18 - 12N P P - K C 1 6020410 108
CM 18 - 12N P P - K W 1 6020389 108
CM 30 - 16B P P - K C 1 6020475 110
CM 30 - 16B P P - K W 1 6020473 110
CM 30 - 25N P P - K C 1 6020477 110
CM 30 - 25N P P - K W 1 6020476 110
CQ 35 - 25N P P - K C 1 6020479 112
CQ 35 - 25N P P - K W 1 6020478 112
IH 03 - 0B6 N S - V U 1 6020142 56
IH 03 - 0B6 P S - V U 1 6020141 56
IH 04 - 0B8 N S - V T 1 6020152 58
IH 04 - 0B8 N S - V W 1 6020149 58
IH 04 - 0B8 P S - V T 1 6020114 58
IH 04 - 0B8 P S - V W 1 6020113 58
IH 06 - 02B N S - V T 1 7900180 62
IH 06 - 02B N S - V W 1 7900178 62
IH 06 - 02B P S - V T 1 7900179 62
IH 06 - 02B P S - V W 1 7900177 62
IH 06 - 04N N S - V T 1 7900184 62
IH 06 - 04N N S - V W 1 7900182 62
IH 06 - 04N P S - V T 1 7900183 62
IH 06 - 04N P S - V W 1 7900181 62
IH 06 - 1B5 N S - V T K 6020170 60
IH 06 - 1B5 N S - V W K 6020166 60
IH 06 - 1B5 P S - V T K 6020169 60
IH 06 - 1B5 P S - V W K 6020165 60
IH 20 - 10N U O - K U 0 7902131 90
IH 20 - 10N U S - K U 0 7902130 90
IH 34 - 30N U O - K U 0 7902135 92
IH 34 - 30N U S - K U 0 7902134 92
IM 04 - 0B6 N S - Z U 1 6020146 20
IM 04 - 0B6 P S - Z U 1 6020145 20
IM 05 - 0B8 N S - Z T 1 6020158 22
IM 05 - 0B8 N S - Z W 1 6020155 22
IM 05 - 0B8 P S - Z T 1 6020110 22
IM 05 - 0B8 P S - Z W 1 6011591 22
IM 08 - 01B - N - Z W 0 6021123 98
IM 08 - 02B N O - Z T 1 7900008 28
IM 08 - 02B N S - Z T 1 7900006 28
IM 08 - 02B N S - Z W 1 7900002 28
IM 08 - 02B P O- Z T 1 7900007 28
IM 08 - 02B P O- Z W 1 7900003 28
IM 08 - 02B P S - Z T 1 7900005 28
IM 08 - 02B P S - Z W 1 7900001 28
IM 08 - 04N N O - Z T 1 7900016 28
IM 08 - 04N N S - Z T 1 7900014 28
IM 08 - 04N N S - Z W 1 7900010 28
IM 08 - 04N P O - Z T 1 7900015 28
IM 08 - 04N P O - Z W 1 7900011 28
IM 08 - 04N P S - Z T 1 7900013 28
IM 08 - 04N P S - Z W 1 7900009 28
IM 08 - 1B5 N O - Z W 1 6020218 24
IM 08 - 1B5 N S - Z C 1 6020224 24
IM 08 - 1B5 N S - Z T 1 6020220 24
IM 08 - 1B5 N S - Z T K 6020176 26
IM 08 - 1B5 N S - Z W 1 6020216 24
IM 08 - 1B5 N S - Z W K 6020173 26
IM 08 - 1B5 P O - Z T 1 6020221 24
IM 08 - 1B5 P O - Z W 1 6020217 24
IM 08 - 1B5 P S - Z C 1 6020223 24
IM 08 - 1B5 P S - Z T 1 6020219 24
IM 08 - 1B5 P S - Z T K 6020112 26
IM 08 - 1B5 P S - Z W 1 6020215 24
IM 08 - 1B5 P S - Z W K 6020111 26
IM 08 - 2N5 N S - Z C 1 6020236 24
IM 08 - 2N5 N S - Z T 1 6020232 24
IM 08 - 2N5 N S - Z W 1 6020228 24
IM 08 - 2N5 P S - Z C 1 6020235 24
IM 08 - 2N5 P S - Z T 1 6020231 24
IM 08 - 2N5 P S - Z W 1 6020227 24
IM 12 - 04B N S - Z C 1 7900038 34
IM 12 - 04B N S - Z W 1 7900034 34
IM 12 - 04B P O - Z C 1 7900039 34
IM 12 - 04B P O - Z W 1 7900035 34
IM 12 - 04B P S - Z C 1 7900037 34
IM 12 - 04B P S - Z W 1 7900033 34
IM 12 - 08N N O - Z W 1 7900044 34
IM 12 - 08N N S - Z C 1 7900046 34
IM 12 - 08N N S - Z W 1 7900042 34
IM 12 - 08N P O - Z C 1 7900047 34
IM 12 - 08N P O - Z W 1 7900043 34
IM 12 - 08N P S - Z C 1 7900045 34
IM 12 - 08N P S - Z W 1 7900041 34
IM 12 - 02B A O - Z U 0 7902119 84
IM 12 - 02B A S - Z U 0 7902118 84
IM 12 - 02B C P - Z C 1 7902928 38
IM 12 - 02B C P - Z W 1 7902927 38
IM 12 - 02B D S - Z C 1 6020312 78
IM 12 - 02B D S - Z W 1 6020310 78
IM 12 - 02B N O - Z C 1 6011974 30
Type designation Order No. Page
179
SICK8 007 755.0300
Type designation Order No. Page Type designation Order No. Page
Index
Type designation
IM 12 - 02B N O - Z W 1 6011966 30
IM 12 - 02B N P - Z C 1 7902924 36
IM 12 - 02B N S - Z C 1 6011972 30
IM 12 - 02B N S - Z C K 1017440 32
IM 12 - 02B N S - Z T 1 6011968 30
IM 12 - 02B N S - Z U K 1017438 32
IM 12 - 02B N S - Z W 1 6011964 30
IM 12 - 02B - N - Z W 0 6021124 100
IM 12 - 02B P O- Z C 1 6011973 30
IM 12 - 02B P O- Z W 1 6011965 30
IM 12 - 02B P P - Z C 1 7902923 36
IM 12 - 02B P S - Z C 1 6011971 30
IM 12 - 02B P S - Z C K 1017428 32
IM 12 - 02B P S - Z T 1 6011967 30
IM 12 - 02B P S - Z U K 1017426 32
IM 12 - 02B P S - Z W 1 6011963 30
IM 12 - 04N A O - Z U 0 7902121 84
IM 12 - 04N A S - Z U 0 7902120 84
IM 12 - 04N C P - Z C 1 7902930 38
IM 12 - 04N C P - Z W 1 7902929 38
IM 12 - 04N D S - Z C 1 6020316 78
IM 12 - 04N D S - Z W 1 6020314 78
IM 12 - 04N N O - Z W 1 6011978 30
IM 12 - 04N N P - Z C 1 7902926 36
IM 12 - 04N N S - Z C 1 6011984 30
IM 12 - 04N N S - Z C K 1017441 32
IM 12 - 04N N S - Z T 1 6011980 30
IM 12 - 04N N S - Z U K 1017439 32
IM 12 - 04N N S - Z W 1 6011976 30
IM 12 - 04N - N - Z W 0 6021125 100
IM 12 - 04N P O - Z C 1 6011985 30
IM 12 - 04N P O - Z W 1 6011977 30
IM 12 - 04N P P - Z C 1 7902925 36
IM 12 - 04N P S - Z C 1 6011983 30
IM 12 - 04N P S - Z C K 1017429 32
IM 12 - 04N P S - Z T 1 6011979 30
IM 12 - 04N P S - Z U K 1017427 32
IM 12 - 04N P S - Z W 1 6011975 30
IM 18 - 05B C P - Z C 1 7902936 48
IM 18 - 05B C P - Z W 1 7902935 48
IM 18 - 05B D S - Z C 1 6020320 80
IM 18 - 05B D S - Z W 1 6020318 80
IM 18 - 05B N P - Z C 1 7902932 46
IM 18 - 05B N S - Z C 1 6011992 40
IM 18 - 05B N S - Z C K 1017444 42
IM 18 - 05B N S - Z U K 1017442 42
IM 18 - 05B N S - Z W 1 6011988 40
IM 18 - 05B - N - Z W 0 6021126 102
IM 18 - 05B P O- Z C 1 6011993 40
IM 18 - 05B P O- Z W 1 6011989 40
IM 18 - 05B P P - Z C 1 7902931 46
IM 18 - 05B P S - Z C 1 6011991 40
IM 18 - 05B P S - Z C K 1017432 42
IM 18 - 05B P S - Z U K 1017430 42
IM 18 - 05B P S - Z W 1 6011987 40
IM 18 - 05B U O - Z U 0 7902123 86
IM 18 - 05B U S - Z U 0 7902122 86
IM 18 - 08B N S - Z C 1 7900086 44
IM 18 - 08B N S - Z W 1 7900082 44
IM 18 - 08B P O- Z C 1 7900087 44
IM 18 - 08B P O- Z W 1 7900083 44
IM 18 - 08B P S - Z C 1 7900085 44
IM 18 - 08B P S - Z W 1 7900081 44
IM 18 - 08N C P - Z C 1 7902938 48
IM 18 - 08N C P - Z W 1 7902937 48
IM 18 - 08N D S - Z C 1 6020324 80
IM 18 - 08N D S - Z W 1 6020322 80
IM 18 - 08N N O - Z W 1 6011998 40
IM 18 - 08N N P - Z C 1 7902934 46
IM 18 - 08N N S - Z C 1 6012000 40
IM 18 - 08N N S - Z C K 1017445 42
IM 18 - 08N N S - Z U K 1017443 42
IM 18 - 08N N S - Z W 1 6011996 40
IM 18 - 08N - N - Z W 0 6021127 102
IM 18 - 08N P O - Z C 1 6012001 40
IM 18 - 08N P P - Z C 1 7902933 46
IM 18 - 08N P S - Z C 1 6011999 40
IM 18 - 08N P S - Z C K 1017433 42
IM 18 - 08N P S - Z U K 1017431 42
IM 18 - 08N P S - Z W 1 6011995 40
IM 18 - 08N U O - Z U 0 7902125 86
IM 18 - 08N U S - Z U 0 7902124 86
IM 18 - 12N N S - Z C 1 7900098 44
IM 18 - 12N N S - Z W 1 7900094 44
IM 18 - 12N P O - Z C 1 7900099 44
IM 18 - 12N P O - Z W 1 7900095 44
IM 18 - 12N P S - Z C 1 7900097 44
IM 18 - 12N P S - Z W 1 7900093 44
IM 30 - 10B D S - Z C 1 6020328 82
IM 30 - 10B D S - Z W 1 6020326 82
IM 30 - 10B N S - Z C 1 6020279 50
IM 30 - 10B N S - Z C K 1017448 52
180 SICK 8 007 755.0300
Type designation Order No. Page Type designation Order No. Page
IM 30 - 10B N S - Z U K 1017446 52
IM 30 - 10B N S - Z W 1 6020275 50
IM 30 - 10B - N - Z W 0 6021128 104
IM 30 - 10B P O- Z C 1 6020280 50
IM 30 - 10B P S - Z C 1 6020278 50
IM 30 - 10B P S - Z C K 1017436 52
IM 30 - 10B P S - Z U K 1017434 52
IM 30 - 10B P S - Z W 1 6020274 50
IM 30 - 10B U O - Z U 0 7902127 88
IM 30 - 10B U S - Z U 0 7902126 88
IM 30 - 15B N S - Z C 1 7900146 54
IM 30 - 15B N S - Z W 1 7900142 54
IM 30 - 15B P O- Z C 1 7900147 54
IM 30 - 15B P O- Z W 1 7900143 54
IM 30 - 15B P S - Z C 1 7900145 54
IM 30 - 15B P S - Z W 1 7900141 54
IM 30 - 15N D S - Z C 1 6020332 82
IM 30 - 15N D S - Z W 1 6020330 82
IM 30 - 15N N S - Z C 1 6020287 50
IM 30 - 15N N S - Z C K 1017449 52
IM 30 - 15N N S - Z U K 1017447 52
IM 30 - 15N N S - Z W 1 6020283 50
IM 30 - 15N - N - Z W 0 6021129 104
IM 30 - 15N P O - Z W 1 6020284 50
IM 30 - 15N P S - Z C 1 6020286 50
IM 30 - 15N P S - Z C K 1017437 52
IM 30 - 15N P S - Z U K 1017435 52
IM 30 - 15N P S - Z W 1 6020282 50
IM 30 - 15N U O - Z U 0 7902129 88
IM 30 - 15N U S - Z U 0 7902128 88
IM 30 - 20N N S - Z C 1 7900158 54
IM 30 - 20N N S - Z W 1 7900154 54
IM 30 - 20N P O - Z C 1 7900159 54
IM 30- 20N P O - Z W 1 7900155 54
IM 30 - 20N P S - Z C 1 7900157 54
IM 30 - 20N P S - Z W 1 7900153 54
IQ 05 - 0B8 N S - Z U 1 6020162 64
IQ 05 - 0B8 P S - Z U 1 6020161 64
IQ 08 - 02B N S - K T 0 7900198 66
IQ 08 - 02B N S - K U 0 7900196 66
IQ 08 - 02B P S - K T 0 7900197 66
IQ 08 - 02B P S - K U 0 7900195 66
IQ 08 - 04N P S - K T 0 7900201 66
IQ 08 - 04N P S - K U 0 7900199 66
IQ 10 - 03B N S - K T 0 7900206 68
IQ 10 - 03B N S - K U 0 7900204 68
IQ 10 - 03B P S - K T 0 7900205 68
IQ 10 - 03B P S - K U 0 7900203 68
IQ 10 - 06N N S - K T 0 7900210 68
IQ 10 - 06N N S - K U 0 7900208 68
IQ 10 - 06N P S - K T 0 7900209 68
IQ 10 - 06N P S - K U 0 7900207 68
IQ 12 - 03B N S - K T 0 1016461 70
IQ 12 - 03B N S - K U 0 1016299 70
IQ 12 - 03B P S - K T 0 1016276 70
IQ 12 - 03B P S - K U 0 1016275 70
IQ 12 - 06N P S - K T 0 1016467 70
IQ 12 - 06N P S - K U 0 1016463 70
IQ 40 - 15B P P - K K 0 7900219 72
IQ 40 - 15B P S - K C 0 7900223 74
IQ 40 - 15B U P - K K 0 7902136 94
IQ 40 - 20B P P -K C K 6012014 74
IQ 40 - 20N P P - K K 0 7900221 72
IQ 40 - 20N U P - K K 0 7902137 94
IQ 40 - 35N P P - K C K 6012015 74
IQ 40 - 35N P S - K C 0 7900224 74
IQ 80 - 60N P P - K K 0 7900227 76
IQ 80 - 60N U P - K K 0 7902138 96
MM08 - 60A P S - Z T 0 7900266 120
MM08 - 60A P S - Z U 0 7900264 120
MM12 - 60A - N - Z C 0 7900287 128
MM12 - 60A - N - Z W 0 7900286 128
MM12 - 60A P S - Z C 0 7900270 122
MM12 - 60A P S - Z U 0 7900268 122
MM18 - 70A - N - Z C 0 7900289 130
MM18 - 70A - N - Z W 0 7900288 130
MM18 - 70A P S - Z C 0 7900274 124
MM18 - 70A P S - Z U 0 7900272 124
MQ10 - 60A N S - K T 0 7900281 126
MQ10 - 60A N S - K U 0 7900279 126
MQ10 - 60A P S - K T 0 7900280 126
MQ10 - 60A P S - K U 0 7900278 126
MZ F1 - 03V P S - K P 0 7900597 152
MZ F1 - 03V P S - K U 0 7900596 152
MZ F1 - 03V P S - K U B 7903147 152
MZ K1 - 02V P S - A T 0 7900604 148
MZ K1 - 02V P S - A U 0 7900602 148
MZ K3 - 02V P S - A T 0 7901952 150
MZ P3 - 03V - N - A C 0 7901441 164
MZ P3 - 03V - N - A W 0 7901440 164
MZ P3 - 03V P S - A C 0 7900612 144
Index
Type designation
181
SICK8 007 755.0300
Type designation Order No. Page Type designation Order No. Page
Index
Type designation
MZ P3 - 03V P S - A U 0 7900610 144
MZ P4 - 03V - N - A C 0 7901330 166
MZ P4 - 03V - N - A W 0 7901329 166
MZ P4 - 03V P S - A C 0 7900616 146
MZ P4 - 03V P S - A U 0 7900614 146
MZ R1 - 03V N S - A U 0 7900593 136
MZ R1 - 03V P S - A T 0 7900594 136
MZ R1 - 03V P S - A U 0 7900592 136
MZ R2 - 03V - N - A W 0 7901321 160
MZ R2 - 03V P S - A T 0 7900600 138
MZ R2 - 03V P S - A U 0 7900598 138
MZ T1 - 03V P S - K P 0 1016910 154
MZ T1 - 03V P S - K W 0 1016809 154
MZ U2 - 03V P S - D C M 1017450 158
MZ U2 - 03V P S - T C M 1017451 158
MZ Z1 - 03V - N - A C 0 7901324 162
MZ Z1 - 03V - N - A W 0 7901323 162
MZ Z1 - 03V N S - A C 0 7900609 140
MZ Z1 - 03V P S - A C 0 7900608 140
MZ Z1 - 03V P S - A U 0 7900606 140
MZ Z2 - 03V P S - K C 0 7900624 142
MZ Z2 - 03V P S - K U 0 7900622 142
MZ Z2 - 03Z N S - K U 0 7900619 142
MZ Z2 - 03Z P S - K C 0 7900620 142
MZ Z2 - 03Z P S - K U 0 7900618 142
RZ F1 - 03Z U S - K P 0 7903376 152
RZ F1 - 03Z U S - K W 0 7903466 152
RZ R1- 03Z U S - A T 0 7901265 136
RZ R1- 03Z U S - A W 0 7901264 136
RZ T1 - 03Z R S - K P 0 1016912 156
RZ T1 - 03Z R S - K W 0 1016911 156
182 SICK 8 007 755.0300
Order No. Type designation Page Order No. Type designation Page
Index
Or der numbers
1016275 IQ 12 - 03B P S - K U 0 70
1016276 IQ 12 - 03B P S - K T 0 70
1016299 IQ 12 - 03B N S - K U 0 70
1016461 IQ 12 - 03B N S - K T 0 70
1016463 IQ 12 - 06N P S - K U 0 70
1016467 IQ 12 - 06N P S - K T 0 70
1016809 MZT1 - 03V P S - K W0 154
1016910 MZT1 - 03V P S - K P 0 154
1016911 RZT1 - 03Z R S - K W0 156
1016912 RZT1 - 03Z R S - K P 0 156
1017426 IM12 - 02B P S - Z U K 32
1017427 IM12 - 04N P S - Z U K 32
1017428 IM12 - 02B P S - Z C K 32
1017429 IM12 - 04N P S - Z C K 32
1017430 IM18 - 05B P S - Z U K 42
1017431 IM18 - 08N P S - Z U K 42
1017432 IM18 - 05B P S - Z C K 42
1017433 IM18 - 08N P S - Z C K 42
1017434 IM30 - 10B P S - Z U K 52
1017435 IM30 - 15N P S - Z U K 52
1017436 IM30 - 10B P S - Z C K 52
1017437 IM30 - 15N P S - Z C K 52
1017438 IM12 - 02B N S - Z U K 32
1017439 IM12 - 04N N S - Z U K 32
1017440 IM12 - 02B N S - Z C K 32
1017441 IM12 - 04N N S - Z C K 32
1017442 IM18 - 05B N S - Z U K 42
1017443 IM18 - 08N N S - Z U K 42
1017444 IM18 - 05B N S - Z C K 42
1017445 IM18 - 08N N S - Z C K 42
1017446 IM30 - 10B N S - Z U K 52
1017447 IM30 - 15N N S - Z U K 52
1017448 IM30 - 10B N S - Z C K 52
1017449 IM30 - 15N N S - Z C K 52
1017450 MZU2 - 03V P S - D C M 158
1017451 MZU2 - 03V P S - T C M 158
6011591 IM05 - 0B8 P S - Z W1 22
6011963 IM12 - 02B P S - Z W1 30
6011964 IM12 - 02B N S - Z W1 30
6011965 IM12 - 02B P O - Z W1 30
6011966 IM12 - 02B N O - Z W1 30
6011967 IM12 - 02B P S - Z T 1 30
6011968 IM12 - 02B N S - Z T 1 30
6011971 IM12 - 02B P S - Z C 1 30
6011972 IM12 - 02B N S - Z C 1 30
6011973 IM12 - 02B P O - Z C 1 30
6011974 IM12 - 02B N O - Z C 1 30
6011975 IM12 - 04N P S - Z W1 30
6011976 IM12 - 04N N S - Z W1 30
6011977 IM12 - 04N P O - Z W1 30
6011978 IM12 - 04N N O - Z W1 30
6011979 IM12 - 04N P S - Z T 1 30
6011980 IM12 - 04N N S - Z T 1 30
6011983 IM12 - 04N P S - Z C 1 30
6011984 IM12 - 04N N S - Z C 1 30
6011985 IM12 - 04N P O - Z C 1 30
6011987 IM18 - 05B P S - Z W1 40
6011988 IM18 - 05B N S - Z W1 40
6011989 IM18 - 05B P O - Z W1 40
6011991 IM18 - 05B P S - Z C 1 40
6011992 IM18 - 05B N S - Z C 1 40
6011993 IM18 - 05B P O - Z C 1 40
6011995 IM18 - 08N P S - Z W1 40
6011996 IM18 - 08N N S - Z W1 40
6011998 IM18 - 08N N O - Z W1 40
6011999 IM18 - 08N P S - Z C 1 40
6012000 IM18 - 08N N S - Z C 1 40
6012001 IM18 - 08N P O - Z C 1 40
6012014 IQ40 - 20B P P - K C K 74
6012015 IQ40 - 35N P P - K C K 74
6020110 IM05 - 0B8 P S - Z T 1 22
6020111 IM08 - 1B5 P S - Z WK 26
6020112 IM08 - 1B5 P S - Z T K 26
6020113 IH04 - 0B8 P S - V W1 58
6020114 IH04 - 0B8 P S - V T 1 58
6020136 CM18 - 08B P P - K W1 108
6020141 IH03 - 0B6 P S - V U 1 56
6020142 IH03 - 0B6 N S - V U 1 56
6020145 IM04 - 0B6 P S - Z U 1 20
6020146 IM04 - 0B6 N S - Z U 1 20
6020149 IH04 - 0B8 N S - V W1 58
6020152 IH04 - 0B8 N S - V T 1 58
6020155 IM05 - 0B8 N S - Z W1 22
6020158 IM05 - 0B8 N S - Z T 1 22
6020161 IQ05 - 0B8 P S - Z U 1 64
6020162 IQ05 - 0B8 N S - Z U 1 64
6020165 IH06 - 1B5 P S - V WK 60
6020166 IH06 - 1B5 N S - V WK 60
6020169 IH06 - 1B5 P S - V T K 60
6020170 IH06 - 1B5 N S - V T K 60
6020173 IM08 - 1B5 N S - Z WK 26
6020176 IM08 - 1B5 N S - Z T K 26
183
SICK8 007 755.0300
Order No. Type designation Page Order No. Type designation Page
6020215 IM08 - 1B5 P S - Z W1 24
6020216 IM08 - 1B5 N S - Z W1 24
6020217 IM08 - 1B5 P O - Z W1 24
6020218 IM08 - 1B5 N O - Z W1 24
6020219 IM08 - 1B5 P S - Z T 1 24
6020220 IM08 - 1B5 N S - Z T 1 24
6020221 IM08 - 1B5 P O - Z T 1 24
6020223 IM08 - 1B5 P S - Z C 1 24
6020224 IM08 - 1B5 N S - Z C 1 24
6020227 IM08 - 2N5 P S - Z W1 24
6020228 IM08 - 2N5 N S - Z W1 24
6020231 IM08 - 2N5 P S - Z T 1 24
6020232 IM08 - 2N5 N S - Z T 1 24
6020235 IM08 - 2N5 P S - Z C 1 24
6020236 IM08 - 2N5 N S - Z C 1 24
6020274 IM30 - 10B P S - Z W1 50
6020275 IM30 - 10B N S - Z W1 50
6020278 IM30 - 10B P S - Z C 1 50
6020279 IM30 - 10B N S - Z C 1 50
6020280 IM30 - 10B P O - Z C 1 50
6020282 IM30 - 15N P S - Z W1 50
6020283 IM30 - 15N N S - Z W1 50
6020284 IM30 - 15N P O - Z W1 50
6020286 IM30 - 15N P S - Z C 1 50
6020287 IM30 - 15N N S - Z C 1 50
6020310 IM12 - 02B D S - Z W1 78
6020312 IM12 - 02B D S - Z C 1 78
6020314 IM12 - 04N D S - Z W1 78
6020316 IM12 - 04N D S - Z C 1 78
6020318 IM18 - 05B D S - Z W1 80
6020320 IM18 - 05B D S - Z C 1 80
6020322 IM18 - 08N D S - Z W1 80
6020324 IM18 - 08N D S - Z C 1 80
6020326 IM30 - 10B D S - Z W1 82
6020328 IM30 - 10B D S - Z C 1 82
6020330 IM30 - 15N D S - Z W1 82
6020332 IM30 - 15N D S - Z C 1 82
6020388 CM18 - 08B P P - K C 1 108
6020389 CM18 - 12N P P - K W1 108
6020410 CM18 - 12N P P - K C 1 108
6020473 CM30 - 16B P P - K W1 110
6020475 CM30 - 16B P P - K C 1 110
6020476 CM30 - 25N P P - K W1 110
6020477 CM30 - 25N P P - K C 1 110
6020478 CQ35 - 25N P P - K W1 112
6020479 CQ35 - 25N P P - K C 1 112
6021123 IM08 - 01B - N - Z W0 98
6021124 IM12 - 02B - N - Z W0 100
6021125 IM12 - 04N - N - Z W0 100
6021126 IM18 - 05B - N - Z W0 102
6021127 IM18 - 08N - N - Z W0 102
6021128 IM30 - 10B - N - Z W0 104
6021129 IM30 - 15N - N - Z W0 104
7900001 IM08 - 02B P S - Z W1 28
7900002 IM08 - 02B N S - Z W1 28
7900003 IM08 - 02B P O - Z W1 28
7900005 IM08 - 02B P S - Z T 1 28
7900006 IM08 - 02B N S - Z T 1 28
7900007 IM08 - 02B P O - Z T 1 28
7900008 IM08 - 02B N O - Z T 1 28
7900009 IM08 - 04N P S - Z W1 28
7900010 IM08 - 04N N S - Z W1 28
7900011 IM08 - 04N P O - Z W1 28
7900013 IM08 - 04N P S - Z T 1 28
7900014 IM08 - 04N N S - Z T 1 28
7900015 IM08 - 04N P O - Z T 1 28
7900016 IM08 - 04N N O - Z T 1 28
7900033 IM12 - 04B P S - Z W1 34
7900034 IM12 - 04B N S - Z W1 34
7900035 IM12 - 04B P O - Z W1 34
7900037 IM12 - 04B P S - Z C 1 34
7900038 IM12 - 04B N S - Z C 1 34
7900039 IM12 - 04B P O - Z C 1 34
7900041 IM12 - 08N P S - Z W1 34
7900042 IM12 - 08N N S - Z W1 34
7900043 IM12 - 08N P O - Z W1 34
7900044 IM12 - 08N N O - Z W1 34
7900045 IM12 - 08N P S - Z C 1 34
7900046 IM12 - 08N N S - Z C 1 34
7900047 IM12 - 08N P O - Z C 1 34
7900081 IM18 - 08B P S - Z W1 44
7900082 IM18 - 08B N S - Z W1 44
7900083 IM18 - 08B P O - Z W1 44
7900085 IM18 - 08B P S - Z C 1 44
7900086 IM18 - 08B N S - Z C 1 44
7900087 IM18 - 08B P O - Z C 1 44
7900093 IM18 - 12N P S - Z W1 44
7900094 IM18 - 12N N S - Z W1 44
7900095 IM18 - 12N P O - Z W1 44
7900097 IM18 - 12N P S - Z C 1 44
7900098 IM18 - 12N N S - Z C 1 44
7900099 IM18 - 12N P O - Z C 1 44
7900141 IM30 - 15B P S - Z W1 54
7900142 IM30 - 15B N S - Z W1 54
Index
Or der numbers
184 SICK 8 007 755.0300
Order No. Type designation Page Order No. Type designation Page
Index
Or der numbers
7900143 IM30 - 15B P O - Z W1 54
7900145 IM30 - 15B P S - Z C 1 54
7900146 IM30 - 15B N S - Z C 1 54
7900147 IM30 - 15B P O - Z C 1 54
7900153 IM30 - 20N P S - Z W1 54
7900154 IM30 - 20N N S - Z W1 54
7900155 IM30 - 20N P O - Z W1 54
7900157 IM30 - 20N P S - Z C 1 54
7900158 IM30 - 20N N S - Z C 1 54
7900159 IM30 - 20N P O - Z C 1 54
7900177 IH06 - 02B P S - V W1 62
7900178 IH06 - 02B N S - V W1 62
7900179 IH06 - 02B P S - V T 1 62
7900180 IH06 - 02B N S - V T 1 62
7900181 IH06 - 04N P S - V W1 62
7900182 IH06 - 04N N S - V W1 62
7900183 IH06 - 04N P S - V T 1 62
7900184 IH06 - 04N N S - V T 1 62
7900195 IQ08 - 02B P S - K U 0 66
7900196 IQ08 - 02B N S - K U 0 66
7900197 IQ08 - 02B P S - K T 0 66
7900198 IQ08 - 02B N S - K T 0 66
7900199 IQ08 - 04N P S - K U 0 66
7900201 IQ08 - 04N P S - K T 0 66
7900203 IQ10 - 03B P S - K U 0 68
7900204 IQ10 - 03B N S - K U 0 68
7900205 IQ10 - 03B P S - K T 0 68
7900206 IQ10 - 03B N S - K T 0 68
7900207 IQ10 - 06N P S - K U 0 68
7900208 IQ10 - 06N N S - K U 0 68
7900209 IQ10 - 06N P S - K T 0 68
7900210 IQ10 - 06N N S - K T 0 68
7900219 IQ40 - 15B P P - K K 0 72
7900221 IQ40 - 20N P P - K K 0 72
7900223 IQ40 - 15B P S - K C 0 74
7900224 IQ40 - 35N P S - K C 0 74
7900227 IQ80 - 60N P P - K K 0 76
7900264 MM08 - 60A P S - Z U 0 120
7900266 MM08 - 60A P S - Z T 0 120
7900268 MM12 - 60A P S - Z U 0 122
7900270 MM12 - 60A P S - Z C 0 122
7900272 MM18 - 70A P S - Z U 0 124
7900274 MM18 - 70A P S - Z C 0 124
7900278 MQ10 - 60A P S - K U 0 126
7900279 MQ10 - 60A N S - K U 0 126
7900280 MQ10 - 60A P S - K T 0 126
7900281 MQ10 - 60A N S - K T 0 126
7900286 MM12 - 60A - N - Z W0 128
7900287 MM12 - 60A - N - Z C 0 128
7900288 MM18 - 70A - N - Z W0 130
7900289 MM18 - 70A - N - Z C 0 130
7900592 MZR1 - 03V P S - A U 0 136
7900593 MZR1 - 03V N S - A U 0 136
7900594 MZR1 - 03V P S - A T 0 136
7900596 MZF1 - 03V P S - K U 0 152
7900597 MZF1 - 03V P S - K P 0 152
7900598 MZR2 - 03V P S - A U 0 138
7900600 MZR2 - 03V P S - A T 0 138
7900602 MZK1 - 02V P S - A U 0 148
7900604 MZK1 - 02V P S - A T 0 148
7900606 MZZ1 - 03V P S - A U 0 140
7900608 MZZ1 - 03V P S - A C 0 140
7900609 MZZ1 - 03V N S - A C 0 140
7900610 MZP3 - 03V P S - A U 0 144
7900612 MZP3 - 03V P S - A C 0 144
7900614 MZP4 - 03V P S - A U 0 146
7900616 MZP4 - 03V P S - A C 0 146
7900618 MZZ2 - 03Z P S - K U 0 142
7900619 MZZ2 - 03Z N S - K U 0 142
7900620 MZZ2 - 03Z P S - K C 0 142
7900622 MZZ2 - 03V P S - K U 0 142
7900624 MZZ2 - 03V P S - K C 0 142
7901264 RZR1 - 03Z U S - A W0 136
7901265 RZR1 - 03Z U S - A T 0 136
7901321 MZR2 - 03V - N - A W0 160
7901323 MZZ1 - 03V - N - A W0 162
7901324 MZZ1 - 03V - N - A C 0 162
7901329 MZP4 - 03V - N - A W0 166
7901330 MZP4 - 03V - N - A C 0 166
7901440 MZP3 - 03V - N - A W0 164
7901441 MZP3 - 03V - N - A C 0 164
7901952 MZK3 - 02V P S - A T 0 150
7902118 IM12 - 02B A S - Z U 0 84
7902119 IM12 - 02B A O - Z U 0 84
7902120 IM12 - 04N A S - Z U 0 84
7902121 IM12 - 04N A O - Z U 0 84
7902122 IM18 - 05B U S - Z U 0 86
7902123 IM18 - 05B U O - Z U 0 86
7902124 IM18 - 08N U S - Z U 0 86
7902125 IM18 - 08N U O - Z U 0 86
7902126 IM30 - 10B U S - Z U 0 88
7902127 IM30 - 10B U O - Z U 0 88
185
SICK8 007 755.0300
Order No. Type designation Page Order No. Type designation Page
7902128 IM30 - 15N U S - Z U 0 88
7902129 IM30 - 15N U O - Z U 0 88
7902130 IH20 - 10N U S - K U 0 90
7902131 IH20 - 10N U O - K U 0 90
7902134 IH34 - 30N U S - K U 0 92
7902135 IH34 - 30N U O - K U 0 92
7902136 IQ40 - 15B U P - K K 0 94
7902137 IQ40 - 20N U P - K K 0 94
7902138 IQ80 - 60N U P - K K 0 96
7902923 IM12 - 02B P P - Z C 1 36
7902924 IM12 - 02B N P - Z C 1 36
7902925 IM12 - 04N P P - Z C 1 36
7902926 IM12 - 04N N P - Z C 1 36
7902927 IM12 - 02B C P - Z W1 38
7902928 IM12 - 02B C P - Z C 1 38
7902929 IM12 - 04N C P - Z W1 38
7902930 IM12 - 04N C P - Z C 1 38
7902931 IM18 - 05B P P - Z C 1 46
7902932 IM18 - 05B N P - Z C 1 46
7902933 IM18 - 08N P P - Z C 1 46
7902934 IM18 - 08N N P - Z C 1 46
7902935 IM18 - 05B C P - Z W1 48
7902936 IM18 - 05B C P - Z C 1 48
7902937 IM18 - 08N C P - Z W1 48
7902938 IM18 - 08N C P - Z C 1 48
7903147 MZF1 - 03V P S - K U B 152
7903376 RZF1 - 03Z U S - K P 0 152
7903466 RZF1 - 03Z U S - K W0 152
186 SICK 8 007 755.0300
SICK Industrial sensor systems
Divisions
Industrial sensors:
The current range of optical and
inductive sensors reflects the
experience of more than 50 years of
partnership with virtually every sector
of industrial automation.
The tasks: recording, counting,
classifying and positioning objects,
detecting shape and position, colour
and surface differences, even under
extreme surrounding conditions.
SICK sensors optimise production
and logistics processes and therefore
contribute to improving product
quality.
Products:
Photoelectric switches and
photoelectric proximitiy switches,
distance sensors, complex sensors,
reflex light grids, multi-dimensional
sensors, inductive proximity sensors,
capacitive proximity sensors,
magnetic proximity sensors,
magnetic cylinder sensors.
Safety systems
In automated production and
logistics processes, safety light
curtains, light grids, laser scanners
and interlocks assure effective
accident prevention and personal
protection. Through long years of
experience in innumerable industrial
applications, pioneering safety
products have been developed
which have set new standards in
many fields. Thanks to its
comprehensive expertise in
designing, manufacturing and
operating safety equipment, SICK
has become the leader in its industry.
Products:
Guarding surfaces, danger points,
danger zones, preventing access,
safety interlocks, software for CE
conformity assessment of plant and
machinery.
187
SICK8 007 755.0300
Environmental monitoring
In power stations and industrial plants,
SICK systems monitor compliance with
statutory limit values for toxic
emissions, thereby supporting process
operation and improvement. SICH is
the only manufacturer to offer a
complete program of units for in situ
and extractive measurement processes.
Pioneering SICK systems, e.g. fog-
measuring units and sensors for
controlling tunnel-ventilation equipment,
are also responsible for keeping traffic
flowing freely on the roads.
Products:
Dust measurement, gas velocity
measuring systems, analysers and
analysis systems for process and
emission monitoring, tunnel-sensor
systems.
Auto Ident
SICK barcode scanners are in demand
wherever products and goods have to
be identified quickly, safely and reliably.
SICK laser scanners have also become
indispensable in applications involving
the classification and positioning of
products or automatic flow control.
They reliably record shape, position and
contour.
They also monitor access roads, multi-
storey car parks, subway stations, level
crossings and locks, i.e. wherever the
safe and smooth flow of traffic is
essential.
Products:
Stationary barcode readers, data-
transmitting photoelectric switches,
laser measuring systems for indoor and
outdoor applications, hand-held
barcode reading systems for mobile
and stationary use.