Raychem Raychem Limited Registration Number: 674709 London, England Faraday Road, Dorcan Registered Office: Rolls House Swindon SN3 5HH ? Rolls Buildings, Fetter Lane Tet: (0793) 28171 LONDON EC4A 1NH Telex 449409 99T 1111 Issue 1 October 1989 (cr 7. CABLE, ELECTRIC, ONE CONDUCTOR, POLYESTER INSULATED, ZEROHALOGEN JACKETED, LIGHTWEIGHT, 600 VOLT The complete requirements for procuring the wire herein shall consist of this document and the issue in effect of Raychem Specification WCD 282 and WCD 2015 as applicable. SHIELD - Tin Plated Copper - 85% coverage COMPONENT - . JACKET - 99T0111 < SY Extruded Crosslinked WP URE Zerohal* Material EPL Pe, J&* LES PART WIRE | SHIELD JACKET | OUTSIDE | MAXIMUM NUMBER SIZE SIZE | THICKNESS| DIAMETER | WEIGHT (mm) (mm) (mm) (kg/km) MIN | NOM | NOM|MAX 99T1111-24-*-* 24 0.10 0.28 | 0.33 | 2.15 | 2.25 9.64 99T1111-22-*-* 22 0.10 0.28 | 0.33 | 2.31 | 2.43 11.95 99T1111-20-*-* 20 0.10 0.28 | 0.33 | 2.56 | 2.69 15.96 99T1111-18-*-* 18 0.10 0.28 | 0.33 | 2.81 | 2.95 20.71 99T1111-16-*-* 16 0.10 0.28 | 0.33 | 3.06 | 3.21 26.19 99T1111-14-*-* 14 0.10 0.28 | 0.33 | 3.36 | 3.53 33.22 99T1111-12-*-* 12 0.10 0.28 | 0.33 | 3.81 | 4.00 46.44 COMPONENT: To meet all the reqiuirements of component wire Specification Control Drawing ADDITIONAL CABLE REQUIREMENTS TEMPERATURE RATING: 105C for 10,000 hours VOLTAGE TEST: 2.5kV 1 minute JACKET COLOUR: Black preferred PART NUMBER: designator in accordance with Mil Std 681. The ' in the part number shall be replaced by a standard colour code ie: 99T1111-20-9-0, Size 20 conductor white insulation, black jacket. * Zerohal is a trade mark of Raychem Ltd. This drawing and the information set forth hereon are the property of Raychem Ltd. and are to be held intrust and confidence. Publication, duplication, disclosure or use for any purpose not expressly authorised in writing by Raychem Ltd. is prohibited This specification sheet takes precedence over documents referenced herein. As Raychem itd reserve the right to make changes in construction without notice please contact Raychem Ltd. to ensure that this documentis the latestissue GB-I-W-17(IEC 332 Part 1) DESIGN PROD. MAN. TECH. Qc. f). .MAN. ENG. ~ NN iA * , : } } 4 aE ntl] (ale eau, PF 3-u-ga | es 3) e4 | PERFORMANCE AND TEST REQUIREMENTS TO WCD 2015 WCD 2015 FREQUENCY DEFINITION REQUIREMENTS Clause No 5.11 IL Jacket concentricity 70% minimum 6.1.1 100% Spark Test 1.5kV rms 50/60Hz __No failures Impulse Test 6.0kV peak No failures 6.1.3 PQ Jacket Insulation Resistance 1.0 Mohms km 6.1.4 IL Heat shock 4 hours at 150C + 3C, 4x mandrel, no cracking, dripping flowing of jacket material. No dielectric failure 1kV ac 5 seconds 6.1.12 IL Jacket Tensile Strength 8N/mm minimum 6.1.12 IL Jacket Elongation 200% minimum 7.2.1 PQ Jacket Heat Ageing 200C, 4 hours, 60% minimum retention of tensile strength and elongation 7.2.1 OA Jacket Limiting Oxygen Index 29 minimum 7.2.1 OA Jacket Temperature Index 250C 7.2.1 QA Jacket Toxicity 5 maximum 7.2.1 QA Jacket Halogen Content Negative result for halogens 7.21 OA Jacket Smoke Index 20 maximum N/A PO Flammability BS 4066 50mm maximum burn length