Data sheet PROmax PRO MAX3 480W 24V 20A Weidmuller Interface GmbH & Co. KG Klingenbergstrae 16 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com Similar to illustration PROmax offers diverse solutions for demanding automation. Our high performance and durable PROmax switchmode power supply units are designed for especially demanding requirements. PROmax reliably copes with continuous overload of up to 20% or short-term peak loads of 300% occurring with high control cabinet temperatures. High boost capability and full power are also made possible in a wide temperature range. Our switch-mode power supply units can be used around the world and are also suitable for confined spaces thanks to their low width. Together with our uninterruptible DC USPs, the diode modules or CAP modules, you can create a power supply solution that is tailored to your requirements. General ordering data Type Order No. Version GTIN (EAN) Qty. PRO MAX3 480W 24V 20A 1478190000 Power supply, switch-mode power supply unit, 24 V 4050118286144 1 pc(s). Creation date December 20, 2018 10:00:02 PM CET Catalogue status 07.12.2018 / We reserve the right to make technical changes. 1 Data sheet PROmax PRO MAX3 480W 24V 20A Weidmuller Interface GmbH & Co. KG Klingenbergstrae 16 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com Technical data Dimensions and weights Width Height Depth Net weight 70 mm 130 mm 150 mm 1,600 g Width (inches) Height (inches) Depth (inches) 2.756 inch 5.118 inch 5.905 inch 5...95 %, no condensation -25 C -40 C -40 C...85 C Operating temperature, max. Storage temperature, max. Operating temperature 70 C 85 C -25 C...70 C AC input voltage range 3 x 320...3 x 575 V AC / 2 x 360...2 x 575 V AC 0.7 A @ 800 V DC / 1.2 A @ 450 V DC Temperatures Humidity at operating temperature Operating temperature, min. Storage temperature, min. Storage temperature Environmental Product Compliance REACH SVHC Lead 7439-92-1 Input AC current consumption Connection system DC input voltage range Input fuse (internal) Rated input voltage Standby power consumption, max. 0,7A @ 3*500 VAC / 0,85 @ 3*400 VAC Screw connection 450...800 V DC (max. 500 V DC acc. to UL508) Yes 3 x 400...3 x 500 V AC (wide-range input) 1W DC current consumption Frequency range AC Inrush current Recommended back-up fuse Surge protection 45...65 Hz max. 15 A 3 - 5 A Char. C, circuit breaker Varistor output Connection system Output power Output voltage Protection against inverse voltage Rated (nominal) output current @ UNom Reserve capacity @ URated Screw connection 480 W 22.5...29.5 V (adjustable via potentiometer) Yes 20 A @ 60 C 24 A (1 min), 30 A (4s) Continuous output current @ URated Output voltage Parallel connection option Pulsed current capacity @ URated Rated output voltage Residual ripple, breaking spikes 24 A @ 45C, 15 A @ 70C 24 V yes, max. 3 60 A (2ms) 24 V DC 1 % < 50 mVss @ UNenn, Full Load Creation date December 20, 2018 10:00:02 PM CET Catalogue status 07.12.2018 / We reserve the right to make technical changes. 2 Data sheet PROmax PRO MAX3 480W 24V 20A Weidmuller Interface GmbH & Co. KG Klingenbergstrae 16 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com Technical data General data AC failure bridging time @ INom Degree of efficiency Earth leakage current, max. MTBF min. 20 ms 91.5% 3.5 mA >500.000h (25C, IEC 61709 (SN29500)) -25 C...70 C 5.5 W Operating temperature Power loss, idling Protection against reverse voltages from the load 30...35 V DC Series switching capability Yes Start-up Surge voltage category Current limiting Derating Housing version Mounting position, installation notice Power factor (approx.) Power loss, nominal load Protection degree Short-circuit protection Status indication -40 C III > 120 % IN > 60C / 75% @ 70C Metal, corrosion resistant Horizontal on TS35 mounting rail. 50 mm of clearance at top & bottom for air circ. Can mount side by side with no space in between. > 0.85 @ 3*400 V AC 36 W IP20 Yes LED red/green and relay (21.6 V DC LED green, relay on/ 20.6 LED red, relay off) EMC / shock / vibration Noise emission in accordance with EN55032 Interference immunity test acc. to Vibration resistance IEC 60068-2-6 Class B EN 55024, EN 55022, Shock resistance IEC 60068-2-27 IEC61000-3-2,-3, IEC61000-4-2,-3,-4,-5,-6,-8,-11 2.3 g 30 g in all directions Insulation coordination Class of protection Insulation voltage input / earth Insulation voltage, input/output Surge voltage category I, with PE connection 3.5 kV 4 kV III Humidity at operating temperature Insulation voltage output / earth Pollution severity 5...95 %, no condensation 0.5 kV 2 For use with electronic equipment Acc. to EN50178 / VDE0160 VDE0100-410 / acc. to DIN57100-410 Electrical safety (applied standards) Electrical machine equipment Protection against dangerous shock currents Safety extra-low voltage Acc. to EN60204 Acc. to VDE0106-101 SELV acc. to EN60950, PELV acc. to EN60204, IEC61204 Protective separation / protection against electrical shock Safety transformers for switch-mode power supplies nach EN61558-2-16 Connection data (input) Conductor cross-section, AWG/kcmil , max. Conductor cross-section, flexible , min. Conductor cross-section, rigid , min. Number of terminals Tightening torque, max. Wire connection cross section, flexible (input), max. 10 0.22 mm 0.18 mm 4 for L1/L2/L3/PE 0.6 Nm Conductor cross-section, AWG/kcmil , min. Conductor cross-section, rigid , max. Connection system Screwdriver blade Tightening torque, min. 26 6 mm Screw connection 0.8 x 4.0, PZ 1 0.5 Nm 4 mm Creation date December 20, 2018 10:00:02 PM CET Catalogue status 07.12.2018 / We reserve the right to make technical changes. 3 Data sheet PROmax PRO MAX3 480W 24V 20A Weidmuller Interface GmbH & Co. KG Klingenbergstrae 16 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com Technical data Connection data (output) Conductor cross-section, AWG/kcmil , max. Conductor cross-section, flexible , max. Conductor cross-section, rigid , max. Connection system Screwdriver blade Tightening torque, min. 10 4 mm 6 mm Screw connection 0.8 x 4.0, PZ 1 0.5 Nm Conductor cross-section, AWG/kcmil , min. Conductor cross-section, flexible , min. Conductor cross-section, rigid , min. Number of terminals Tightening torque, max. 26 0.22 mm 0.18 mm 8 (++,---,11,13,14) 0.6 Nm Floating contact Yes Signalling Contact load (NO contact) Status indication max. 30 V DC / 1 A LED red/green and relay (21.6 V DC LED green, relay on/ 20.6 LED red, relay off) Approvals Institute (GERMLLOYD) Certificate No. (GERMLLOYD) Institute (cULus) Certificate no. (cULus) Institute (cULusEX) Certificate no. (cULusEX) Institute (cURus) Certificate No. (cURus) TAA00000TT E258476 E470829 E255651 Classifications ETIM 5.0 eClass 6.2 eClass 8.1 eClass 9.1 EC002541 27-04-90-04 27-04-90-04 27-04-07-01 ETIM 6.0 eClass 7.1 eClass 9.0 EC002540 27-04-90-04 27-04-07-03 Product information Descriptive text ordering data The internal varistor found in a switch-mode power supply does not replace the need for surge protection within a system. Creation date December 20, 2018 10:00:02 PM CET Catalogue status 07.12.2018 / We reserve the right to make technical changes. 4 Data sheet PROmax PRO MAX3 480W 24V 20A Technical data Weidmuller Interface GmbH & Co. KG Klingenbergstrae 16 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com Approvals Approvals ROHS Conform Downloads Approval/Certificate/Document of Conformity Brochure/Catalogue Engineering Data Engineering Data User Documentation DE_PA5200_160310_001.pdf CAT 4.3 ELECTR 15/16 EN EPLAN, WSCAD STEP Operating instructions Operating instructions Creation date December 20, 2018 10:00:02 PM CET Catalogue status 07.12.2018 / We reserve the right to make technical changes. 5 Data sheet PROmax PRO MAX3 480W 24V 20A Weidmuller Interface GmbH & Co. KG Klingenbergstrae 16 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com Drawings Electric symbol Derating curve Derating curve Creation date December 20, 2018 10:00:02 PM CET Catalogue status 07.12.2018 / We reserve the right to make technical changes. 6