90
XTRA
GUARD®Flexible Cables
STANDARD-FLEX CONTROL CABLE
OIL RESISTANT, MULTICONDUCTOR, UNSHIELDED
UL AWM STYLE 2587
CSA AWM II A/B FT1
600 VOLT
CHARACTERISTICS
OPERATING TEMPERATURE:
–5°C to 90°C (Flexing)
–40°C to 90°C (Stationary)
VOLTAGE RATING:
600 Volt
COLOR DESCRIPTION:
Color Code: Numerically Numbered (Alternate and
Inverted) Black Conductors with One Yellow/Green
Conductor on Outside Layer (Yellow/Green
Conductor on 3 Conductor and Above Only.)
Jacket Color: Gray
PRODUCT DESCRIPTION:
Conductor: Finely Stranded Bare Copper
Insulation: Lubricated PVC
Fillers: Non-Wicking, Solid PVC Rod
Jacket: Oil Resistant PVC
SPECIFICATIONS
Bend Radius: 5X Cable Diameter
UL AWM Style 2587
CSA AWM II A/B FT1
Jacket Meets VDE 0472, Section 803 Oil Test
CE LVD-CD 73/23/EEC Modified by CD 93/68/EEC
CHOOSE
XTRAGUARD
STANDARD-FLEX CONTROL
CABLES FOR
:
Outstanding Oil and Chemical Resistance
UL Recognized and CSA Certified, CE Marked
Jacket Meets VDE 0472, Section 803 Oil Test
Ease of Installation
NOT FOR USE IN HIGH-FLEX APPLICATIONS
XTRAGUARD
STANDARD-FLEX
CABLE APPLICATIONS
:
Applications Requiring Increased Flexibility
Machine Tools
CNC Machine Centers
Data Processing Equipment
Automation Equipment
Material Handling Equipment
AVAILABILITY
In Stock: Bulk, Cut to Length
20 AWG (0,50mm
2
), 10/30 (10/0,25mm), Insulation Thickness: 0.022" (0,56mm)
65002 2 0.035 0,89 0.230 5,8
65003 3 0.035 0,89 0.240 6,1
65004 4 0.035 0,89 0.260 6,6
65005 5 0.035 0,89 0.290 7,4
65007 7 0.035 0,89 0.310 7,9
65009 9 0.040 1,00 0.410 10,4
65012 12 0.045 1,10 0.420 10,7
65018 18 0.055 1,40 0.510 13,0
65025 25 0.055 1,40 0.590 15,0
Alpha No. of Jacket Thickness Nominal Diameter
Part No. Cond. Inches mm Inches mm
18 AWG (1,0mm
2
), 16/30 (16/0,25mm), Insulation Thickness: 0.022" (0,56mm)
65802 2 0.035 0,89 0.250 6,4
65803 3 0.035 0,89 0.260 6,6
65804 4 0.035 0,89 0.285 7,2
65805 5 0.035 0,89 0.310 7,9
65807 7 0.035 0,89 0.340 8,6
65809 9 0.035 0,89 0.445 11,3
65812 12 0.045 1,10 0.460 11,7
65818 18 0.050 1,30 0.550 14,0
65825 25 0.050 1,30 0.635 16,1
65834 34 0.060 1,50 0.750 19,1
65841 41 0.063 1,60 0.810 20,6
Alpha No. of Jacket Thickness Nominal Diameter
Part No. Cond. Inches mm Inches mm
16 AWG (1,5mm
2
), 26/30 (26/0,25mm), Insulation Thickness: 0.022" (0,56mm)
65602 2 0.035 0,89 0.275 7,0
65603 3 0.035 0,89 0.290 7,4
65604 4 0.035 0,89 0.315 8,0
65605 5 0.035 0,89 0.350 8,9
65607 7 0.035 0,89 0.380 9,7
65609 9 0.040 1,00 0.510 13,0
65612 12 0.050 1,30 0.530 13,5
65618 18 0.050 1,30 0.620 15,7
65625 25 0.055 1,40 0.750 19,1
65641 41 0.075 1,90 0.940 23,9
Alpha No. of Jacket Thickness Nominal Diameter
Part No. Cond. Inches mm Inches mm
14 AWG (2,5mm
2
), 41/30 (41/0,25mm), Insulation Thickness: 0.022" (0,56mm)
65402 2 0.045 1,10 0.325 8,3
65403 3 0.045 1,10 0.345 8,8
65404 4 0.055 1,40 0.400 10,2
65405 5 0.055 1,40 0.430 10,9
65407 7 0.055 1,40 0.470 11,9
65409 9 0.065 1,70 0.615 15,6
65412 12 0.085 2,20 0.660 16,8
65418 18 0.090 2,30 0.770 19,6
65425 25 0.110 2,80 0.945 24,0
Alpha No. of Jacket Thickness Nominal Diameter
Part No. Cond. Inches mm Inches mm
12 AWG (4,0mm
2
), 65/30 (65/0,25mm), Insulation Thickness: 0.022" (0,56mm)
65203 3 0.065 1,70 0.440 11,2
65204 4 0.080 2,00 0.500 12,7
65205 5 0.085 2,20 0.550 14,0
Alpha No. of Jacket Thickness Nominal Diameter
Part No. Cond. Inches mm Inches mm
10 AWG (6,0mm
2
), 105/30 (105/0,25mm), Insulation Thickness: 0.022" (0,56mm)
65103 3 0.080 2,00 0.510 13,0
65104 4 0.085 2,20 0.560 14,2
65105 5 0.090 2,30 0.620 15,7
Alpha No. of Jacket Thickness Nominal Diameter
Part No. Cond. Inches mm Inches mm
®
MADE IN U.S.A.
FIT
®TUBING RECOMMENDATION
FIT
®FLEX Highly Flexible, Irradiated Silicone Rubber
(See Page 134 for Product Specifications)
FIT
®-650 Chemical and Temperature Resistant Irradiated Viton®
(See Page 132 for Product Specifications)
Viton®is a registered trademark of DuPont Dow Elastomers
Toll Free: 1-800-52 ALPHA • Telephone: 908-925-8000 • Fax: 908-925-6923 Web Site: www.alphawire.com
Europe/UK Telephone: +44 (0) 1932 772422 • Europe/UK Fax: +44 (0) 1932 772433 Email: info@alphawire.com