9100 Coax - 75 Ohm Coax For more information please call 1-800-Belden1 See Put-ups and Colors Description: Series 59, 20 AWG solid .032" bare copper-covered steel conductor, gas-injected foam polyethylene insulation, duofoil(R) or duobond(R) + aluminum braid shield (40% coverage), PVC jacket. PHYSICAL CHARACTERISTICS: CONDUCTOR: Number of Coax 1 Total Number of Conductors 1 Series Type Series 59 AWG 20 Stranding Solid Conductor Diameter .032 in. Conductor Material BCCS - Bare Copper Covered Steel INSULATION: Insulation Material Gas-injected FPE - Foam Polyethylene Insulation Diameter .144 in. OUTER SHIELD: Outer Shield Material Trade Name Duobond(R) II Outer Shield Type Tape/Braid Outer Shield Material : Layer Number 1 Trade Name Bonded Duofoil(R) Type Tape 2 Braid Outer Shield %Coverage 100 % Material % Coverage (%) Bonded Aluminum Foil100 Polyester Tape-Aluminum Foil AL - Aluminum 40 OUTER JACKET: Outer Jacket Material PVC - Polyvinyl Chloride OVERALL NOMINAL DIAMETER: Overall Nominal Diameter .237 in. MECHANICAL CHARACTERISTICS: Page 1 of 4 9100 Coax - 75 Ohm Coax Operating Temperature Range -40C To +80C UL Temperature Rating 80C Bulk Cable Weight 20 lbs/1000 ft. Max. Recommended Pulling Tension 80 lbs. Min. Bend Radius (Install) 2.5 in. APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE: APPLICABLE STANDARDS: NEC/(UL) Specification CM, CATV CEC/C(UL) Specification CM EU CE Mark (Y/N) Yes EU RoHS Compliant (Y/N) Yes EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004 PMSHA Specification P-MSHA-SC-182/4 FLAME TEST: UL Flame Test UL1685 UL Loading PLENUM/NON-PLENUM: Plenum (Y/N) N ELECTRICAL CHARACTERISTICS: Nom. Characteristic Impedance 75 +/-3 Ohms Nom. Inductance .097 H/ft Nom. Capacitance Conductor to Shield 16.2 pF/ft Nominal Velocity of Propagation 83 % Nominal Delay 1.2 ns/ft Nom. Conductor DC Resistance @ 20 Deg. C 44.5 Ohms/1000 ft Nominal Outer Shield DC Resistance @ 20C 17 Ohms/1000 ft Minimum Return Loss : Description Frequency (MHz) Start Frequency (MHz) Stop Frequency (MHz) 5 1000 Max. Attenuation : Page 2 of 4 Minimum Return Loss (dB) 20 9100 Coax - 75 Ohm Coax Description Frequency (MHz) Start Frequency (MHz) Stop Frequency (MHz) 5 55 211 270 300 350 400 450 550 750 870 1000 Max. Operating Voltage - UL Max. Attenuation (dB/100 ft.) 0.89 1.95 3.59 4.05 4.27 4.64 4.88 5.30 5.90 6.96 7.54 8.09 300 V RMS NOTES: Notes Sweep tested 5 MHz to 1 GHz. PUT-UPS AND COLORS: Item Description 9100 009U1000 #20 GIFHDLDPE SH FRPVC 9100 0101000 #20 GIFHDLDPE SH FRPVC 9100 010U1000 #20 GIFHDLDPE SH FRPVC 9100 010U500 #20 GIFHDLDPE SH FRPVC Revision Number: 1 Put-Up (ft.) U1000 Ship Weight (lbs.) 23 Jacket Color WHITE 1000 24 BLACK U1000 23 BLACK U500 12 BLACK Revision Date: 08-18-2005 Page 3 of 4 Notes 9100 Coax - 75 Ohm Coax (c) 2005 Belden Wire & Cable Company All Rights Reserved. Although Belden Electronics Division ("Belden") makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden CDT Electronics Division believes this product to be in compliance with the following environmental regulations: California Proposition 65 Consent Judgment For Wire & Cable Mfgs.(San Francisco Superior Court Nos. 312962 And 320342); EU RoHS (Directive 2002/95/EC, 27-Jan-2003);Material manufactured prior to the compliance date may still be in stock at Belden facilities and in our Distributor's inventory. EU ELV (Directive 2000/53/EC, 18-Sept-2000); EU WEEE (Directive 2002/96/EC, 27-Jan-2003); And EU BFR (Directive 2003/11/EC, 6-Feb-2003). The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden's knowledge, information and belief at the date of its publication. The information provided in the Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Belden CDT Electronics Division declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC. Page 4 of 4