• RoHS compliant
• Lead free
Applications:
• Multi-phase regulators
• Voltage Regulator Module (VRM)
• Desktop and server VRMs and EVRDs
• Notebook regulators
• Data networking and storage systems
• Graphics cards and battery power systems
• Point-of-load modules
• DCR sensing
Environmental Data:
• Storage temperature range: -40°C to +125°C
• Operating temperature range: -40°C to +125°C
(ambient plus self-temperature rise)
• Solder reflow temperature: J-STD-020D compliant
Packaging:
• Supplied in tape and reel packaging on 13” diameter reel
• FP1007R1 700 parts per reel
• FP1007R2 750 parts per reel
• FP1007R3 650 parts per reel
Product Specifications
Part Number7OCL1± 10% (nH) FLL2Min. (nH) Irms3(Amps) Isat14@ 25°C (Amps) Isat25@ 125°C (Amps) DCR (mW) @ 20°C K-factor6
R1 Version
FP1007R1-R12-R 120 86 81 65 371
FP1007R1-R14-R 140 100 72 56 371
FP1007R1-R17-R 170 122 60 58 46 0.29 ± 10% 371
FP1007R1-R22-R 215 155 50 36 371
FP1007R1-R30-R 300 216 32 26 371
R2 Version
FP1007R2-R12-R 120 86 81 65 368
FP1007R2-R14-R 140 100 72 56 368
FP1007R2-R17-R 170 122 51 58 46 0.48 ± 8% 368
FP1007R2-R22-R 215 155 50 36 368
FP1007R2-R30-R 300 216 32 26 368
R3 Version
FP1007R3-R12-R 120 86 94 86 354
FP1007R3-R15-R 150 108 76 70 354
FP1007R3-R17-R 170 122 66 60 354
FP1007R3-R22-R 215 155 61 50 43 0.29 ± 5% 354
FP1007R3-R23-R 230 165 48 40 354
FP1007R3-R27-R 270 194 40 34 354
FP1007R3-R30-R 300 216 35 30 354
Description:
• Halogen free
• 125°C maximum total temperature operation
• 10.4 x 8.0 x 6.5, 7.0 or 7.5mm maximum surface mount package
• Ferrite core material
• High current carrying capacity, low core losses
• Controlled DCR tolerance for sensing circuits
• Inductance range from 120nH to 300nH
• Current range from 32 to 94 Amps
• Frequency range up to 2MHz
High Current, High Frequency, Power Inductors
FLAT-PAC™ FP1007 Series
0910 BU-SB10927 Page 1 of 4 Data Sheet: 4341
SMD Device
1 Open Circuit Inductance (OCL) Test Parameters: 100kHz, 0.10Vrms, 0.0Adc
2 Full Load Inductance (FLL) Test Parameters: 100kHz, 0.1Vrms,I
sat1
3I
rms: DC current for an approximate temperature rise of 40°C without core loss. Derating is
necessary for AC currents. PCB pad layout, trace thickness and width, air-flow and proximity of
other heat generating components will affect the temperature rise. It is recommended the part
temperature not exceed 125°C under worst case operating conditions verified in the end
application.
4I
sat1: Peak current for approximately 20% rolloff at +25°C.
5I
sat2: Peak current for approximately 20% rolloff at +125°C.
6 K-factor: Used to determine Bp-p for core loss (see graph). Bp-p = K *L *DI *10-3,B
p-p : (Gauss),
K: (K-factor from table), L: (inductance in nH), DI (peak-to-peak ripple current in amps).
7 Part Number Definition: FP1007Rx-Rxx-R
• FP1007 = Product code and size • Rx is the DCR indicator
• Rxx= Inductance value in mH, R = decimal point • “-R” suffix = RoHS compliant